brochure data center 082114 - bellia office interiors · 2015-06-30 · data center flooring. 3 the...
TRANSCRIPT
TecCrete®
Data Center Flooring
3
Th
e T
ec
Cre
te D
ata
Ce
nte
r p
rod
uc
t is
ba
sed
on
Ha
wo
rth
’s p
rov
en
Te
cC
rete
ac
ce
ss
flo
ori
ng
pla
tfo
rm. F
or
the
la
st 3
0 y
ea
rs, i
t h
as
be
en
th
e l
ea
din
g c
ho
ice
fo
r a
rch
ite
cts
an
d d
ev
elo
pe
rs w
ho
pre
fer
a t
op
-qu
alit
y a
cc
ess
flo
ori
ng
sy
ste
m w
ith
be
st-i
n-c
lass
fea
ture
s. H
aw
ort
h,
a f
am
ily
ow
ne
d m
an
ufa
ctu
rer
ba
sed
in
Mic
hig
an
sin
ce
19
48
,
is c
om
mit
ted
to
ma
kin
g T
ec
Cre
te p
rod
uc
ts i
n t
he
US
A.
Ha
wo
rth
ha
s b
uilt
on
Te
cC
rete
’s l
eg
en
da
ry p
erf
orm
an
ce
an
d d
ura
bili
ty b
y a
dd
ing
tec
hn
olo
gy
-fri
en
dly
su
rfa
ce
fin
ish
es
an
d h
igh
-effi
cie
nc
y a
irfl
ow
pa
ne
ls t
o c
rea
te t
he
Tec
Cre
te D
ata
Ce
nte
r, a
n a
dv
an
ce
d s
yst
em
of
ac
ce
ss fl
oo
rin
g p
rod
uc
ts e
ng
ine
ere
d
spe
cifi
ca
lly f
or
cri
tic
al
co
mp
uti
ng
an
d t
ele
co
mm
un
ica
tio
ns
en
vir
on
me
nts
.
TEC
CRETE D
ATA
CENTER
Th
e G
ree
ne
st A
cce
ss F
loo
r in
th
e I
nd
ust
ry
• 58
% re
cycl
ed c
onte
nt (c
ontr
ibut
es to
LEE
D M
R 4.
1 &
4.2
).
• Ce
rtifi
ed b
y G
reen
guar
d Ch
ildre
n an
d Sc
hool
s as
a lo
w-
emitt
ing
prod
uct (
cont
ribut
es to
LEE
D IE
Q 3
.1).
• M
anuf
actu
red
in o
ur K
entw
ood,
MI p
lant
, a Z
ero
Was
te to
Land
fill f
acili
ty.
3
BE
ST
WA
RR
AN
TY
IN
IN
DU
ST
RY
> 5
Year
Str
uctu
re
> 3
Year
HPL
Del
amin
atio
n
TECC
RETE P
ERFO
RM
ANC
E
Ped
esta
ls f
or s
ta
nda
rd a
nd s
eis
mic
appli
catio
ns
45
1.12
5”
1.5”
Stan
dar
d D
uty
pan
el fo
r ev
eryd
ay a
pp
licat
ion
s.
Hea
vy D
uty
pan
el fo
r h
eavi
er lo
ad r
equi
rem
ents
.
Prod
uct
Stat
ic L
oadi
ng R
atin
gD
ynam
ic L
oad
Ratin
g
Syst
emPa
nel
Und
erst
ruct
ure
Conc
entr
ated
Uni
form
Ulti
mat
eRo
lling
10-
Pass
Rolli
ng 1
0,00
0-Pa
ss
1250
1 1/
8” P
anel
Corn
erlo
ck12
50 lb
s60
0 lb
s18
00 lb
s12
00 lb
s80
0 lb
s
1500
1 1/
8” P
anel
Strin
ger
1500
lbs
700
lbs
2500
lbs
1500
lbs
1250
lbs
2000
1 1/
2” P
anel
Strin
ger
2000
lbs
800
lbs
2800
lbs
1500
lbs
1250
lbs
2500
1 1/
2” P
anel
HD
Str
inge
r25
00 lb
s90
0 lb
s31
00 lb
s20
00 lb
s20
00 lb
s
Type
0Ty
pe 1
Type
2Ty
pe 3
Type
4Ty
pe 5
67
67
Posi
tioni
ng Ta
b•
Built
-in p
ositi
onin
g ta
bs o
n ev
ery
strin
ger
elim
inat
es “r
acki
ng” o
r sk
ewin
g of
pan
el g
rid.
Flat
Und
ersi
de
Allo
ws
for m
ount
ing
scre
ws
to b
e lo
cate
d an
ywhe
re o
n pa
nel w
ithou
t us
ing
stru
ts o
n bo
ttom
.
Prop
rieta
ry C
oncr
ete
and
Stee
l Com
posit
e D
esig
n
• So
lid ro
lling
load
supp
ort.
• St
eel s
hear
tabs
cau
se th
e co
ncre
te a
nd st
eel
to b
ehav
e as
a si
ngle
com
posit
e m
ater
ial, c
ombi
ning
co
mpr
essiv
e st
reng
th a
nd te
nsile
stre
ngth
for u
nmat
ched
st
atic
and
dyn
amic
load
per
form
ance
.
• In
dust
ry’s
only
wel
dles
s ste
el p
an e
nsur
es st
ruct
ural
inte
grity
th
roug
hout
pro
duct
life
cycl
e.
Full
Pane
l Thi
ckne
ss•
Supe
riorl
oad-
bear
ing
supp
ort.
• So
lid 1
1/8
” or 1
1/2
” thi
ck th
roug
hout
en
tire
pane
l.
• Fu
ll pa
nel t
hick
ness
rest
s on
un
ders
truc
ture
, elim
inat
ing
st
ruct
ural
vul
nera
bilit
y at
pan
el
ed
ge a
nd c
orne
r.
Redu
ced
Airb
orne
Cont
amin
ants
• St
ruct
ural
con
cret
e w
on’t
flake
dur
ing
inst
alla
tion.
• Li
mit
dust
in d
ay-t
o-da
y op
erat
ions
.
Eng
ineered f
or r
eli
abil
ity,
safety, and insta
llatio
n e
ase
No
Zin
c w
his
kers
Tec
Cre
te D
ata
Ce
nte
r u
ses
ele
ctr
on
ic
gra
de
me
tal
fin
ish
es
to e
nsu
re t
ha
t n
o
zin
c w
his
kers
de
ve
lop
.
Fla
t U
ndersid
e
• A
llow
s e
asy
mo
un
tin
g o
f se
rve
r ra
cks
or
oth
er
eq
uip
me
nt
to t
he
ac
ce
ss fl
oo
r.
• E
asi
ly a
dd
su
pp
ort
pe
de
sta
ls a
t a
ny
lo
ca
tio
n.
• F
lexi
ble
un
de
rstr
uc
ture
pla
ce
me
nt
aid
s
inst
alla
tio
n o
f c
ut
pa
ne
ls a
t w
alls
an
d c
olu
mn
s.
Serv
er R
ack
Gro
und
Path
• M
ulti-
poin
tgro
undi
ngfo
rdep
enda
ble
sta
tic p
rote
ctio
n an
d el
ectr
ical
safe
ty.
• Tw
o po
ints
of m
etal
-to-
met
al c
onta
ct a
t ea
ch c
orne
r offe
r eig
ht p
oint
s of g
roun
d pa
th re
dund
ancy
on
ever
y pa
nel.
89
25
% o
pe
n a
rea
pe
rfo
rate
d p
an
els
• D
eliv
ers
19%
mor
e ai
r vol
ume
than
com
petit
ive
equi
vale
nt.
• In
tegr
ated
ste
el g
rid w
ithst
ands
hea
vy ro
lling
load
s.
• 10
00 lb
s ro
lling
load
per
CIS
CA S
ectio
n 3.
AIr
flo
w p
anel
optio
ns f
or a
ll
appli
catio
ns
f
tio
ns
55
% o
pe
n a
rea
alu
min
um
gra
tes
• Li
ght,
stro
ng c
ast-
alum
inum
con
stru
ctio
n.
• En
hanc
ed a
irflow
and
coo
ling.
0
0.050.
1
0.150.2
0.25
0.05
0.1
0.2
0.3
0.4
Stat
ic P
ress
ure
In. o
f H20
Air
Lea
kage
Rat
es
TecC
rete
with
Airs
eal
Stee
l Pan
el
Air Leakage (CFM/ft2)
1011
10Th
e H
aw
orth T
ECC
RETE D
ATA
CENTER C
OO
LING
ADVA
NTAG
ET
ECC
RETE I
nteg
ra
l A
ir S
ea
ls
56
% o
pe
n a
rea
Tri
ad
™ C
ha
mfe
r A
irfl
ow
pa
ne
l
fea
ture
s p
ate
nte
d a
irfl
ow
en
ha
nc
em
en
t
tec
hn
olo
gy
.
• St
eel d
esig
n off
ers
heav
y-du
ty lo
ad c
apac
ity.
• M
ulti-
dire
ctio
nal fi
ns u
nder
pan
el in
crea
ses
airfl
ow o
ver
fla
t-bo
ttom
gra
tes.
• H
ighe
r coo
ling
plum
e al
low
s co
ld a
ir to
re
ach
entir
e he
ight
of r
ack.
• U
pper
ser
ver t
empe
ratu
res
can
be
redu
ced
10 –
20
degr
ees
Fahr
enhe
it.
• O
vera
ll co
olin
g re
quire
men
ts m
ay b
e re
duce
d by
as
muc
h as
40%
.
56
% o
pe
n T
ria
d C
ha
mfe
r
Air
flo
w p
an
el.
Air
flo
w f
ins
Hot air recirculation to cold aisle
Str
ati
fic
ati
on
L
ev
el
Air-
Flow
Pan
el
Mo
st s
tan
dar
d g
rate
s o
nly
pro
vid
e e
no
ug
h a
ir v
olu
me
to r
eac
h t
he
low
er
hal
f o
f th
e s
erv
er
rack
.
Improved Hot Aisle Containment flow
Tri
ad
Ch
am
fer
ICE
™
Co
ld A
isle
Co
nta
inm
en
t
Str
ati
fic
ati
on
L
ev
el
Th
e m
ult
i-d
ire
cti
on
al fi
ns
on
Tri
ad
air
flo
w p
an
els
incr
ea
se t
he
vo
lum
e o
f a
ir fl
ow
ing
ag
ain
st a
ll se
rve
r su
rfa
ces,
fro
m b
ott
om
to t
op
.
Air-
Flow
Pan
el
Sta
nd
ard
Pa
ne
ls/G
rate
s
Onl
y Te
cCre
te D
ata
Cent
er p
anel
s ha
ve th
e op
tion
of a
n in
tegr
al a
ir se
al a
ttac
hed
dire
ctly
to th
e pa
nel s
ide.
Hig
hly
dura
ble
silic
on fo
am s
eal.
• O
ptio
nal a
ir se
als
prov
ide
com
pres
sion
fit t
hat
redu
ces
cool
ing
loss
thro
ugh
pane
l sea
ms
by a
s m
uch
as 9
0% o
ver c
onve
ntio
nal u
nsea
led
data
ce
nter
s flo
ors.
• Pr
ovid
es im
prov
ed a
ir-co
ntai
nmen
t with
in d
ata
cent
er p
lenu
m, c
reat
ing
impr
oved
airfl
ow to
gra
tes
or p
erfo
rate
d pa
nels
at s
erve
r rac
ks.
Co
mb
ine
Te
cC
rete
Air
Se
als
wit
h t
he
Tri
ad
Ch
am
fer
Air
flo
w p
an
el
for
the
mo
st e
ffic
ien
t
da
ta c
en
ter
coo
lin
g s
yst
em
.
Air
Le
ak
ag
e:
Co
nv
en
tio
na
l F
loo
r v
s. T
ec
Cre
te w
ith
Air
Se
al
1213
Bare c
rete
data
center
Surfa
ce F
inis
h S
ystem
s
eng
inee
red
fo
r t
he L
ong
Run
and S
uppo
rted
by t
he Industry’s
Lo
ng
est S
tandard W
arranty
Ag
ain
st D
elam
inatio
n
TECC
RETE D
ata
Center
Onl
y Te
cCre
te D
ata
Cent
er p
rodu
cts
offer
a th
ree-
year
w
arra
nty
agai
nst d
elam
inat
ion
of H
PL o
r vin
yl.
Haw
orth
has
app
lied
its s
ixty
yea
r exp
erie
nce
in s
urfa
ce
finis
h ad
hesi
on to
eng
inee
r a fi
nish
, adh
esiv
e, a
nd
subs
trat
e sy
stem
that
wor
ks fl
awle
ssly
, eve
n un
der a
dver
se
cond
ition
s.
Dat
a Ce
nter
sta
ndar
d fin
ishe
s in
clud
e:
• 1/
6” o
r 1/8
” ant
i-sta
tic h
igh-
pres
sure
lam
inat
e
with
TecT
rim e
dge
• 1/
16” o
r 1/8
” con
duct
ive
lam
inat
e w
ith
TecT
rim E
dge
• Co
nduc
tive
Viny
l with
Cap
ture
d Tr
im E
dge
• O
nly
TecC
rete
acc
ess
floor
can
be
used
ba
re w
ith fi
eld
appl
ied
Elec
tras
eal E
SD o
r El
ectr
a-gu
ard
cond
uctiv
e co
atin
gs.
• D
urab
le b
are
finis
h el
imin
ates
the
hass
le
and
expe
nse
resu
lting
from
cra
ckin
g,
chip
ping
or d
elam
inat
ion
of h
igh
pres
sure
lam
inat
e.
• Ba
re ti
les
can
be s
ecur
ed u
sing
co
rner
lock
scr
ews
to e
limin
ate
the
use
of
strin
gers
, sav
ing
both
tim
e an
d ex
pens
e.
• Co
atin
g on
the
Bare
sur
face
bec
omes
an
inte
gral
par
t of t
he p
anel
, yie
ldin
g su
perio
r fun
ctio
n an
d in
crea
sed
life
expe
ctan
cy a
s co
mpa
red
to fa
ctor
y fin
ishe
d hi
gh-p
ress
ure
lam
inat
e pa
nels
.
Tec
Cre
te B
are
—th
e l
ate
st i
n f
inis
hin
g t
ec
hn
olo
gy
Pe
rfo
rma
nce
Du
rab
ility
Ae
sth
eti
c
Aff
ord
ab
ility
pro
duct s
um
mary
So
lid
pa
ne
l sy
ste
m o
pti
on
s:
• Te
cCre
te 1
250
with
out s
trin
ger
• Te
cCre
te 1
500
with
str
inge
r
• Te
cCre
te 1
500s
l with
out s
trin
ger
• Te
cCre
te 2
000
with
str
inge
r
• Te
cCre
te 2
500
with
str
inge
r
So
lid
pa
ne
l fi
nis
h o
pti
on
s:
• Fi
eld-
appl
ied
acry
lic s
urfa
ce fi
nish
• Fi
eld-
appl
ied
Elec
tras
eal™
ESD
fini
sh
• Fi
eld-
appl
ied
Elec
trag
uard
con
duct
ive
finis
h
• Fa
ctor
y-ap
plie
d 1/
16” o
r 1/8
” ant
i-sta
tic o
r con
duct
ive
high
-pre
ssur
e la
min
ate
with
TecT
rim™
edg
e
• Fa
ctor
y-ap
plie
d co
nduc
tive
viny
l with
cap
ture
d tr
im
25
% a
irfl
ow
pa
ne
l fi
nis
h o
pti
on
s:
• Fa
ctor
y ap
plie
d 1/
16” o
r 1/8
” ant
ista
tic o
r con
duct
ive
high
-pre
ssur
e la
min
ate
with
TecT
rim e
dge
• Fa
ctor
y ap
plie
d co
nduc
tive
viny
l with
cap
ture
d tr
im
55
% g
rate
fin
ish
op
tio
ns:
• Po
wde
r-co
at e
poxy
fini
sh
56
% T
ria
d g
rate
fin
ish
an
d fi
n o
pti
on
s:
• Av
aila
ble
with
or w
ithou
t fiel
d-in
stal
labl
e fin
set
s
• Fi
nish
ed in
con
duct
ive
pow
der-
coat
epo
xy
Un
de
rstr
uc
ture
op
tio
ns:
• Se
ism
ic ra
ted
pede
stal
s
• Fl
oor h
eigh
ts fr
om 3
” to
48” F
FH, a
dditi
onal
hei
ghts
av
aila
ble
upon
requ
est
For more information call 800.344.2600 or 616.393.3000.Download additional copies at haworth.com
This brochure is printed on FSC® certified U2®:XG™ paper, manufactured with electricity in the form of renewable energy (wind, hydro, biogas) and contains a minimum of 30% post-consumer recovered fiber. FSC is a global benchmark for responsible forest management.