Page 1: bs20is

Installation

Base Transceiver Station Equipment

IMN:BTSE BS 20

A30808-X3247-G362-2-7631

Page 2: bs20is

2 A30808-X3247-G362-2-7631

IMN:BTSE BS 20 InstallationBase Transceiver Station Equipment

! Important Notice on Product SafetyElevated voltages are inevitably present at specific points in this electrical equipment. Some of theparts can also have elevated operating temperatures.

Non-observance of these conditions and the safety instructions can result in personal injury or in prop-erty damage.

Therefore only trained and qualified personnel may install and maintain the system.

The system complies with the standard EN 60950. All equipment connected has to comply with theapplicable safety standards.

Copyright (C) Siemens AG 2000

Issued by the Public Communication Network GroupHofmannstraße 51D-81359 München

Technical modifications possible.Technical specifications and features are binding only insofar asthey are specifically and expressly agreed upon in a written contract.

Page 3: bs20is

A30808-X3247-G362-2-7631 3

InstallationBase Transceiver Station Equipment

IMN:BTSE BS 20

Reason for UpdateSummary:

Software Correction

Details:

Chapter/Section Reason for Update

2.7.6 Pinning of Shelter Alarm Interface

Issue History

Issue

Number

Date of issue Reason for Update

1 05/00 Software Correction

Page 4: bs20is

4 A30808-X3247-G362-2-7631

IMN:BTSE BS 20 InstallationBase Transceiver Station Equipment

Page 5: bs20is

A30808-X3247-G362-2-7631 5

InstallationBase Transceiver Station Equipment

IMN:BTSE BS 20

This document consists of a total of 52 pages. All pages are issue 2.

Contents

1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91.1 Purpose of the Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91.2 Tasks of the Base Transceiver Stations . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91.3 Standard Technical Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91.4 Types of Base Transceiver Stations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101.5 Installation Prerequisites. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101.6 Handling of the Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101.7 Installation Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101.8 Ancilliary Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

2 BS 20 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122.1 Position in the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122.2 Site Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122.3 Station Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132.4 Construction View of the BS 20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132.5 Equipment Delivery. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142.6 Rack Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152.6.1 Wall Mounting of the BS 20 Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152.6.2 Floor Mounting of the BS 20 Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162.7 External Cabling Activities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172.7.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172.7.2 Ground and Power Supply Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . 182.7.3 48 V DC - External Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202.7.4 Connection of the External Backup Battery . . . . . . . . . . . . . . . . . . . . . . . . 212.7.5 Abis-Interface - PCM Link Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222.7.5.1 Abis-Interface for 120 Ohm Cable Impedance . . . . . . . . . . . . . . . . . . . . . . 232.7.5.2 Abis-Interface for 75 Ohm Cable Impedance . . . . . . . . . . . . . . . . . . . . . . . 252.7.5.3 Abis-Interface without OVPT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262.7.6 Shelter Alarm Interface - Signalling Link Terminal . . . . . . . . . . . . . . . . . . . 272.7.7 Operator Alarm Interface - Signalling Link Terminal . . . . . . . . . . . . . . . . . . 282.7.8 Serial Interface - Signalling Link Terminal . . . . . . . . . . . . . . . . . . . . . . . . . 292.7.9 Interface for Local Maintenance Interface (LMT) . . . . . . . . . . . . . . . . . . . . 302.8 Board Insert Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302.8.1 Installation of the AC/DC Converter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 322.8.2 Installation of the Backup Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 332.9 System Cabling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 342.9.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 342.9.2 RCAP - RXMUCO Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 362.9.3 RXMUCO - TPU connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 362.9.4 TPU - PA Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 372.9.5 PA - HYCOM Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 372.9.6 HYCOM - Backplane Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 382.9.7 HYCOM - RCAP Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

Page 6: bs20is

6 A30808-X3247-G362-2-7631

IMN:BTSE BS 20 InstallationBase Transceiver Station Equipment

2.9.8 DUKIT-Backplane Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 382.9.9 RCAP - DUKIT Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 392.9.10 RXAMCO - TPU Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 402.9.11 DUKIT - RXAMCO Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 402.9.12 RXFIL -RXAMCO Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 402.9.13 PA - DUKIT Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 412.10 Antenna Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 412.10.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 412.10.2 Identification of Antenna Feeder Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . 422.10.3 Transmit Antenna Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 442.10.4 Receive Antenna Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 442.10.5 Transmit/Receive Antenna Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 442.10.6 Identification of Antenna Feeder Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . 452.11 Rack Extension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 452.12 Spare Parts for Field Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 482.13 Post Installation Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

3 Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

Page 7: bs20is

A30808-X3247-G362-2-7631 7

InstallationBase Transceiver Station Equipment

IMN:BTSE BS 20

IllustrationsFig. 1.1 ESD Symbol. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Fig. 2.1 Position of the BS21 within the SBS . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Fig. 2.2 BS 20 site configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Fig. 2.3 Front view of the BS 20 rack (with door open). . . . . . . . . . . . . . . . . . . . 14

Fig. 2.4 Support frame for wall mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Fig. 2.5 Plinth for floor mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Fig. 2.6 Interfaces for external cabling (BS 20 rack from below) . . . . . . . . . . . . 18

Fig. 2.7 Ground-and power supply connections (example) . . . . . . . . . . . . . . . . 19

Fig. 2.8 Preparation of the 230 V AC cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Fig. 2.9 Preparation of the -48 V DC power supply cable. . . . . . . . . . . . . . . . . . 20

Fig. 2.10 Pinning of the “DC for external equipment” interface. . . . . . . . . . . . . . . 21

Fig. 2.11 Pinning of external battery connector . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Fig. 2.12 OVPT with terminal block (120 Ohm) . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Fig. 2.13 OVPT with SMA connectors (75 Ohm) . . . . . . . . . . . . . . . . . . . . . . . . . 25

Fig. 2.14 Preparation of 75 Ohm coaxial cable. . . . . . . . . . . . . . . . . . . . . . . . . . . 26

Fig. 2.15 Location of code keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

Fig. 2.16 Mounting Unit Numbering of the BS 20 rack (equipped with HYCOM andRXMUCO) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

Fig. 2.17 Connection of the AC/DC converter. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

Fig. 2.18 Survey of cabling BS 20, equipped with HYCOM and RXMUCO . . . . . 34

Fig. 2.19 Survey of cabling BS 20, equipped with DUKIT and RXAMCO. . . . . . . 35

Fig. 2.20 Survey of cabling BS 20, equipped with HYCOM, RXAMCO and RXFIL35

Fig. 2.21 BS20 DUKIT connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

Fig. 2.22 Antenna cabling BS 20 (example with HYCOM/RXMUCO). . . . . . . . . . 42

Fig. 2.23 Cell numbering (top view to the antenna pole) . . . . . . . . . . . . . . . . . . . 43

Fig. 2.24 Minimum site dimensions for BS20 rack extension . . . . . . . . . . . . . . . . 46

Fig. 2.25 Rack extension cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

Page 8: bs20is

8 A30808-X3247-G362-2-7631

IMN:BTSE BS 20 InstallationBase Transceiver Station Equipment

TablesTab. 2.1 Pinning of Abis-interface (OVPT 120 Ohm) . . . . . . . . . . . . . . . . . . . . . . 23

Tab. 2.2 Pinning of PCM line monitoring interface (SUB-D9,female) . . . . . . . . . . 24

Tab. 2.3 Pinning of the Abis-interface cable without OVPT (SubD 25 connector) 26

Tab. 2.4 Pinning of the shelter alarm interface . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

Tab. 2.5 Pinning of the operator alarm interface (OAL) . . . . . . . . . . . . . . . . . . . . 28

Tab. 2.6 Signal meaning, operator alarm interface . . . . . . . . . . . . . . . . . . . . . . . . 29

Tab. 2.7 Pinning of the Serial Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

Tab. 2.8 Pinning of the LMT interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

Tab. 2.9 Code keys of RF and core modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

Tab. 2.10 RXin connectors - RXMUCO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

Tab. 2.11 RXin connectors - RXMUCO (diversity) . . . . . . . . . . . . . . . . . . . . . . . . . 36

Tab. 2.12 RXMUCO - TPU connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

Tab. 2.13 RXMUCO (diversity) - TPU connections. . . . . . . . . . . . . . . . . . . . . . . . . 37

Tab. 2.14 TPU - PA connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

Tab. 2.15 PA - HYCOM connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

Tab. 2.16 Connections between HYCOM and RFTX connectors . . . . . . . . . . . . . . 38

Tab. 2.17 RCAP - DUKIT connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

Tab. 2.18 RXAMCO - TPU connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

Tab. 2.19 DUKIT - RXAMCO connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

Tab. 2.20 RXFIL - RXAMCO connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

Tab. 2.21 PA - DUKIT connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

Tab. 2.22 Label colours of antenna feeders for BS20 with DUCOM. . . . . . . . . . . . 43

Tab. 2.23 Label colours of antenna feeders for BS20 with HYCOM. . . . . . . . . . . . 43

Tab. 2.24 Label colours of antenna jumpers for BS20 with DUKIT. . . . . . . . . . . . . 45

Tab. 2.25 Label colours of antenna jumpers for BS20 with HYCOM . . . . . . . . . . . 45

Tab. 2.26 System cabling for rack extension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

Page 9: bs20is

A30808-X3247-G362-2-7631 9

InstallationBase Transceiver Station Equipment

IMN:BTSE BS 20

1 Introduction

1.1 Purpose of the ManualThis document is intended to give information necessary to the installation of the BaseTransceiver Stations for the SBS Base Station System (BSS).

It contains the description of all steps to install the BTS on site and integrate it into therequired infrastructure:– Power supply– PCM - Network– Grounding– Receive / transmit antenna system– Alarm connections– Base constructions

For installation of equipment not supplied by Siemens (battery chargers, antennas,power supplies etc.) refer to site specific documentation or vendor instructionsprovided with other equipment.

1.2 Tasks of the Base Transceiver StationsThe Base Transceiver Station performs the following main tasks in accordance with theGSM-requirement (D900) or DCS-standards (D1800) or PCS standards (D1900):– Provides the RF-link connection to the mobile stations (MS)– Supports various cell types (omni and sector cells)– Provides the PCM link connection to the Base Station Controller (BSC) via

a terrestrial line (in this case symmetric pair or coaxial cable is used)or microwave (additional equipment is therefore required)

– Submultiplexing on the Abis-interface

1.3 Standard Technical Features– Full software download capability– Full rate and half rate Traffic Channels are supported– GSM primary/extended Band ; DCS Band; PCS Band– Hybrid combiners, Duplex combiners and Filter combiners for antenna combining

available– Outstanding Rx sensitivity– 16/64 kBit signalling channels and minimised signalling load on Abis– LMT-operation with full O&M functionality at a transmission rate of 64 kBit– Modular capacity increase of sites

!The CE declaration of conformity for the product will be fulfilled if the setup and cablingis undertaken in accordance with the specification in the manual and the documentationlisted there, such as mounting instructions, cable lists etc.Where necessary, accountshould be taken of project-specific documentation.Deviations from the specifications or independent changes during setup, such as use ofcable types with lower screening values, for example, can lead to the CE requirementsbeing violatad. In such cases the CE declaration of conformity is invalidated and theresponsibility passes to the person who has caused the deviations.

Page 10: bs20is

10 A30808-X3247-G362-2-7631

IMN:BTSE BS 20 InstallationBase Transceiver Station Equipment

1.4 Types of Base Transceiver StationsThe Base Transceiver Stations are a modular family of BTS-products and basedon the same hardware components:– for indoor operation: BS 60 (D900, D1800, D1900): max 6 carrier per rack, serves

up to 3 cells, max. 6 carrier per cell– for indoor operation: BS 20 (D900, D1800): max 2carrier per rack, serves up to 2

cells, max. 2 carrier per cell– for outdoor operation: BS 61 (D900, D1800, D1900): max 6 carrier per rack, serves

up to 3 cells, max. 6 carrier per cell– for outdoor operation: BS 21(D900, D1800,D1900): max 2 carrier per rack, serves

up to 2 cells, max. 2 carrier per cell– for outdoor operation: BS 22(D900, D1800): max 2 carrier per rack, serves up to 2

cells, max. 2 carrier per cell– for indoor and outdoor operation: BS 11 (D900, D1800): max 2 carrier per rack,

serves up to 2 cells, max. 2 carrier per cell

1.5 Installation PrerequisitesIt is absolute required that the installer pays attention to the valid EMC instructions.

Lightning protection zone 1 according IEC 1312-1/DIN VDE 0185 part 103 insidethe construction room is recommended.

All other equipment on site must be CE designated and must provide interfaces forconnecting of external cables conformable to EMC instructions.

1.6 Handling of the ModulesAll boards and modules must be handled with extreme care as each one containselectrostatically sensitive devices (ESD).The modules are marked with the ESD-label.

Fig. 1.1 ESD Symbol

These are sensitive to static discharge.

Notice:– Avoid handling the modules in a high-static environment– When handling the modules, do not touch connector contacts– An earthed high-impedance wrist strap must be worn when handling modules.– Use the socket at the racks for wrist strap connection.– The modules must be transported in appropriate packing

1.7 Installation ToolsThe correct rack installation is carried out with the aid of the following tools:– Standard toolkit for BSS-installation– Spirit-level

Page 11: bs20is

A30808-X3247-G362-2-7631 11

InstallationBase Transceiver Station Equipment

IMN:BTSE BS 20

– Plumb bob– Saw with shavings exhauster filter (for elevated floor only)– Bending device for semi-rigid cables Ø 2.2 mm, Ø 3.6 mm– Torque spanner for SMA connectors (35 N/cm)– Torque spanner for SMC connectors (100 N/cm)– Security Bit Set (for outdoor equipment)

For installation of power supply, transmission equipment, antennas, cableways andother infrastructure equipment, additional tools could be necessary.

1.8 Ancilliary MaterialThe following ancilliary materials are needed :– plumb line– colophony– adhesive tape (yellow/green, green, blue, red, orange, white)– cable fasteners– wire end sleeves for 16 mm copper wires– cable lugs M8– wire end sleeves

Page 12: bs20is

12 A30808-X3247-G362-2-7631

IMN:BTSE BS 20 InstallationBase Transceiver Station Equipment

2 BS 20 Installation

2.1 Position in the SystemLike all other base stations the BS20 interconnects the MS via the Um interfacewith the trunk network via the Abis interface.

Fig. 2.1 Position of the BS21 within the SBS

2.2 Site RequirementsPrior to the commencement of installation, the construction of the room in which thebase transceiver station is to be housed must be complete and the room in good condi-tion and dry - heaters, if necessary, should be put up in the room.Dependend on the power consumption of the BS20, the AC mains output of thepower supply equipment must provide a connected load of 800 W / 3,5 A.

In case of wall mounting, a load-carrying capacity of 2.50 kN/m2 is required for hang upthe BS20. If floor mounting is planned, the floor load capacity must be not less than650 kp/m2. A minimum floor space of 1,50 m x 1,50 m should be provided for bothmounting variants.

The BS20 is intended to be installed in a restricted access area.– Doors and windows must already have been installed and must be lockable.– Openings in wall or ceiling of floor - if required - must be complete.– The floor coverings must have been laid.– Room lighting and wall sockets must have been installed.– Heating or air-conditioning systems should be ready for operation.– Walls and ceilings should have been painted.The room must be clean.– A minimum floor space of 1,50 m x 1,50 m should be provided.– The construction of the installation room requires the realization of

lightning protection zone 1 according IEC 1312-1/DIN VDE 0185 part 103.

To prevent subsequent accumulation of dust and dirt, the parts and equipmentunits to be installed must be unpacked outside the room (if possible).

After that it is advantageous to install the BTS, after all other installation works tocreate the required infrastructure (power supply, antenna cabling, PCM line...)are complete.

Um interface

Abisinterface

Asubinterface

Ainterface

SBS

Page 13: bs20is

A30808-X3247-G362-2-7631 13

InstallationBase Transceiver Station Equipment

IMN:BTSE BS 20

2.3 Station ConfigurationAdditional equipment is necessary for the function of the Base Transceiver Station onsite :

Fig. 2.2 BS 20 site configuration

2.4 Construction View of the BS 20The BTS equipment is housed in the BTS rack with the dimensionsW x D x H = 600 x 450 x 775 mm.The same rack type is used for D900, D900R or D1800 equipment.It contains all parts of BTSE. The modul configuration depends on the site specification.Max. 2 carriers can be installed per rack.

*) dependent on type of network integration

indoor unit

NTPM

outdoo r unit

external alarmdonators

externalbackup batteries(optional)

ground tag

Microwave*equipment

PCM30 link*

PLMN

signalling link terminal

BS 20

Mains / emergency power

Antennafeedercables

TX / RX Antennas

mast headunit(RXAMOD)

batterie +0 V poleconnected to ground

Page 14: bs20is

14 A30808-X3247-G362-2-7631

IMN:BTSE BS 20 InstallationBase Transceiver Station Equipment

Fig. 2.3 Front view of the BS 20 rack (with door open)

2.5 Equipment DeliveryThe rack is shipped in a carton with wooden base (dimensions: 76 x 76 x 100 cmH x W x L). Depending on the pre-installed modules inside the rack, the crate can weighup to approx. 130 kg.

If the rack will be delivered without equipment components with a weight more than1 kg and must be completed on site, an additional carton with the dimension60 x 76 x 80 cm (H x W x L) contains following equipment :– Power Amplifiers– Transceive Processor Units– Antenna Combiner– Backup Batteries– Generic Power Supply– Receive Antenna Modules– AC/DC Converter

Handle each carton containing installation material with extreme caution to avoidtipping.

Fan Unit 0

DC breaker

access for external cabling

backup batteries

power distributionboard

OVPT

RX filter

front door

RXMUCOorRXAMCO0 1 2 3

TP

U 1

PA

1

TP

U 0

PA

0

CC

TR

0

MC

LK 0

LI o

BB

SIG

1B

BS

IG 0

ALC

O 0

AC

/DC

0

GPSU 0

DC

PA

0

DC

TP

U 0

DC

TP

U 1

DC

PA

1

HYCOM 0 or DUKIT 0 or DUPL20R 0

Page 15: bs20is

A30808-X3247-G362-2-7631 15

InstallationBase Transceiver Station Equipment

IMN:BTSE BS 20

2.6 Rack Installation

2.6.1 Wall Mounting of the BS 20 RackPrior to the commencement of rack installation, consult the site documentation to locatethe installation point of the BTS-rack, the PCM30 network termination, the connectionpoint for AC mains, the nearest ground tag and the access of the antenna cables intothe construction room.

For the wall mounting of the rack, a support frame is required.– Mark the 8 drilling points of the frame onto the wall according to the site configura-

tion. Pay attention to the correct horizontal and vertical position of the frame duringthe marking procedure, using the spirit-level !

– Drill holes Ø 8 mm at the marked points, making sure that all nearby equipment isdust protected !

– Fix the frame at the wall by 8 mm dowels and M6x55 screws incl. plain washer(contents of the fixing kit).

– Lift the rack carefully off the base of the shipping crate.– Hang up the rack at the frame. A second person is needed for help.– Open the front door and fix them in open position.– Lead the M12x30 screws through the 6 holes of the rack rear covering into the

tapped holes of the support frame. (screws incl. flat washer and rubber washer arealso contents of the fixing kit)

– Tighten the screws with the socket wrench.

holes forwall mounting

tapped holes forrack fixing

tapped holes forrack fixing

hooks for temporary hang up of the rackduring the fixing activities

500

mm37

0 m

m240

mm11

0 m

m

500 mm

Page 16: bs20is

16 A30808-X3247-G362-2-7631

IMN:BTSE BS 20 InstallationBase Transceiver Station Equipment

Fig. 2.4 Support frame for wall mounting

2.6.2 Floor Mounting of the BS 20 RackBefore starting the installation activities, refer to the site documentation for informationabout the installation point of the BTS-rack, the PCM30 network termination, theconnection point for AC mains, the nearest ground tag and the access of the antennacables into the construction room.

For floor mounting of the rack, a plinth is required.– Mark the plinth-outlines on the floor according to the site configuration floor. (If the

construction room is equipped with a elevated floor and cabling access is requiredfrom below, mark the position of the additional opening.)

– Cut out the opening, making sure that the rack and all nearby equipment is dustprotected !

– Lift or slide the rack carefully off the base of the shipping crate.– Move the plinth to the marked installation point.– Remove the covers signed with (*) from the rack bottom

(see Fig.2.6).– Heave the rack on to the plinth.– Open the front door of the plinth.– Fix the rack on to the plinth. For this purpose pass the M4x8 screws through the

holes at the top of plinth into the tapped holes at the rack bottom.– Tighten the screws with a socket wrench.– Check the correct vertical rack position, using the spirit level. In case the position is

incorrect, equalize differences in the floor height by adjusting the screwed adjusterfeet of the plinth.

– Unscrew both of the eye bolts (located at top of the rack). Retain the bolts forpossible future use.

Page 17: bs20is

A30808-X3247-G362-2-7631 17

InstallationBase Transceiver Station Equipment

IMN:BTSE BS 20

Fig. 2.5 Plinth for floor mounting

2.7 External Cabling Activities

2.7.1 OverviewThis chapter gives information necessary to install the external cables between theBS 20 and the infrastructure equipment.

45

0

450600

The rack cannot function without the following cable connections:- 230 V AC main input connection point for 230 V ACor

-48 V DC input external power supply equipment- ground bolt ground tag- Abis interface PCM30 link terminal

Page 18: bs20is

18 A30808-X3247-G362-2-7631

IMN:BTSE BS 20 InstallationBase Transceiver Station Equipment

All connectors are located at the bottom of the rack. The following figure shows thelocations of the connectors.

Fig. 2.6 Interfaces for external cabling (BS 20 rack from below)

2.7.2 Ground and Power Supply ConnectionsA cable (3x2.5 mm ) is required for connecting the BS 20 rack with the230 V AC /50Hz mains connection point on site. An alternative connection in case of anexternal power supply will be used, is a 48 V DC cable (2x4 mm ) to the power supplyunit on site.

Depending on the site-specific power supply configuration, the rack has to be connecteddirectly with the mains connection point or via a (optional) power distribution panel.

In any case the rack has to be protected by a 10 A breaker (powered by 230 V AC)or 25 A (powered by -48 V DC).

The following figure shows the power supply configuration if the power distribution panelis used.

- 48 V DC output external equipment(e.g. network termination)

- TX/RX antenna connectors transmit/receive antennas

optional connections:- shelter alarm interface signalling link terminal (optional)- operator alarm interface signalling link terminal (optional)- antenna connectors diversity diversity antenna

Air Filter Box

Over Voltage Protection

Tracing Interfacesfor Abis Lines

Abis Interface

Operator Alarm Interface

Serial Interface

Shelter AlarmInterface

LMT Interface

DC for extern.Backup Battery

48 V DC fromextern. Equipment

Receive Antenna 3(RX 3)

Receive Antenna 2(RX 2)

Receive Antenna 1(RX 1)

Receive Antenna 0(RX 0)

Mains Input

(TX 0)

(TX 1)

Ground Bolt

cover *

cover *

Before mounting remove the coverssigned with *

TransmitAntenna 0

TransmitAntenna 1

Page 19: bs20is

A30808-X3247-G362-2-7631 19

InstallationBase Transceiver Station Equipment

IMN:BTSE BS 20

Fig. 2.7 Ground-and power supply connections (example)

A 3 pole IEC 320 plug is located at the bottom of the rack for the 230 V AC mains input.

For connecting the BS 20 rack with the AC mains connection point proceed in steps asfollows:– Check the actual distance between rack and mains connection point or power

distribution panel (if required).– Cut the cable for the required length.– Fix the socket at the end, which has to be connected at the mains input (Fig.2.8).– Lead the main cable to the connection point for 230 V AC.

Fig. 2.8 Preparation of the 230 V AC cable

The interface in case of an external -48 V DC power supply is a splash-proofcircular connector (plug). Preparation and pinning shows Fig. 2.9..

external backup batteries(optional)

ground tag

powerdistribution

panel230 V AC mains

BS 20

48 V DCfor external equipmentH07RN-F-2x4

H07RN-F-2x4 H07V-R 50 mm2

(grn/yel)

H07V-R 16 mm2

(grn/yel)

max. 2 m

H05RR-F-3G 1,5 (230 V AC)

NYY-I 3x2,5

10 A FI (230 VAC)

16Amain breaker

25 A breaker (-48 V DC)

AC counter

-48 V DCpower supplyunit

H07RN-F-2x4

alternative connection

H07RN-F-2x4 (-48 V DC)

power supplyand battery +0 V poleconnected to ground

L

P

Ncable H05RR-F-3G 1,5

socket IEC 320

!The positive pole of an external power supply unit must be connected to ground !

Page 20: bs20is

20 A30808-X3247-G362-2-7631

IMN:BTSE BS 20 InstallationBase Transceiver Station Equipment

Fig. 2.9 Preparation of the -48 V DC power supply cable

Connect rack to ground tag as follows:– Use the nearest ground tag.– Ascertain the distance between the ground tag and ground bolt at the bottom of the

BS 20. If 16 mm copper wire (e.g. H07V-R 16 yellow/green) is used, the distancemust be less than 2 metres !

– Cut the wire to the required length.– Remove the wire covering at the end to connect with the ground bolt (length approx.

7 mm) and fix a cable lug M8.– Connect the prepared cable end at the ground bolt.– Tighten the nut firmly.– Mark both ends of the ground cable with green/yellow adhesive tape.

Note that type of ground tag and mains connection point are subject to modification.A description of the connecting is not subject of this manual. For further information referto the site-specific documentation and use the corresponding documentation of theseparts of the infrastructure equipment.

2.7.3 48 V DC - External EquipmentTo provide for function of external equipment (e.g. microwave, network termination) the48 V DC output located at the bottom of the rack could be used.

A cable (2x4mm )is required for connecting the 48 V DC output with these equipmentparts.

Depending on the site-specific 48 V DC power supply configuration, the rack has to beconnected directly with the external equipment or a (optional) power distribution panelis used.

A splash-proof 2 pole socket is located at the bottom of the rack for the 48 V DC output.

Connect the BS 20 rack with the external equipment in the following steps:– Check the actual distance between rack and the installation points of the equipment.– Cut the cable to the required length.– Fix the CA-CON plug at the end to be connected with the 48 V DC output.

Pay attention to the assembly instructions of the plug and the handling instructionsof the cable which has to be used.

– Remove the screw cap of the socket.– Insert the plug and tighten the screw cap.– Lead the cable to the connection point of external equipment.

A

B

CE

E

splash-proof circular conneVEAM type CIRO6F16-10S

H07RH

Page 21: bs20is

A30808-X3247-G362-2-7631 21

InstallationBase Transceiver Station Equipment

IMN:BTSE BS 20

Note that the types of external equipment are subject to modification.A description of the connection is not part of this manual.For further information refer to the site-specific documentation and use those partscorresponding to the infrastructure equipment.

Fig. 2.10 Pinning of the “DC for external equipment” interface

2.7.4 Connection of the External Backup BatteryTo extend the backup time in case of AC failure, the BS 20 rack could be powered byexternal batteries. A splash-proof 2 pole socket is located at the bottom of the rack forconnect these batteries.

Prior to starting the installation works, consult the site documentation to locate the instal-lation point of the external batteries.

Connect the BS 20 rack with the external backup batteries in the following steps:– Check the distance between the socket "DC for ext. battery" and the connection

point of the battery pack.– Cut the cable (e.g. H07RN-F-2x6 mm ) to the required length.– Fix the CA-CON plug at the end to be connected with the "DC for ext. battery"

socket.Pay attention to the assembly instructions of the plug and the handling instructionsof the cable which has to be used.

– Remove the screw cap of the socket.– Insert the plug and tighten his screw cap.– Lead the cable to the connection point of the battery pack.

Note that types of battery and their connecting are subject to modification. For furtherinformation refer to the site-specific documentation and use the correspondingdocumentation of the manufacturer.

red ( +)blue (-)B A

!The positive pole of the external backup batteries must be connected to ground !

Page 22: bs20is

22 A30808-X3247-G362-2-7631

IMN:BTSE BS 20 InstallationBase Transceiver Station Equipment

Fig. 2.11 Pinning of external battery connector

For connection of the AC/DC converter with the external backup batteries, the uncon-nected wires of the DC/Alarm cable are used.– Insert the prepared ends into the terminal block, located on the left side inside the

rack.– Pay attention to the correct polarity: "+" wire red ; "-" wire blue– Tighten the clamping screws.

2.7.5 Abis-Interface - PCM Link TerminalThe Abis interface, located on RCAP, is terminated with the OvervoltageProtection (OVPT) which protects the LI inside the BS20 against overvoltage(residual voltage < 1 kV).Two types of OVPT are exist (for 75 Ohm or 120 Ohm cables).

Dependend on the different cable impedances is recommended to:– Use screened cable containing 8/10 shielded twisted pairs 0,25 mm2 for 120 Ohm

PCM lines, e.g. MOD-IY-2DY-FCY.– Use coaxial cables for 75 Ohm wiring, e.g. S-09YS(ST)CY 8x2x0.6/1.2.

The maximum cable length depends on the attenuation of the cable, in order to fulfilthe requirements of minimum voltage levels to be provided at Abis interface accordingto PCM standards.The cable shielding must be connected to the relevant ground pins as close as possible(in order to avoid EMC/RF interfering effects).

ABblue (-) red (+)

Page 23: bs20is

A30808-X3247-G362-2-7631 23

InstallationBase Transceiver Station Equipment

IMN:BTSE BS 20

2.7.5.1 Abis-Interface for 120 Ohm Cable Impedance

Fig. 2.12 OVPT with terminal block (120 Ohm)

Connect the Abis-interface with twisted pair cable to the PCM link terminal as follows:– Cut the cable to the required length and cut back the outer insulation

(approx.19 cm). Remove the wire insulation (0,8 mm).– Wrap the exposed cable shield, whitch will be fixed at the stress relieving, with adhe-

sive copper foil (approx. 4 cm).– Fix the prepared cable close to the stress relieving by straps.– Insert the wires into the terminals of the OVPT.– Insert the additional wire (shielding potential) into one of the ground terminals

(e.g. no. 24).– Lead the additional wire and the uplink and downlink wires on the shortest way

(that means without sleeves) between the stress relieving and the screw terminals.– All unconnected PCM lines (4 wires per line) must be connected to one of the

ground terminals.

It is advantageous to protect the short part of the cable between stress relieving andterminal block with a shrink tube or adhesive tape.

terminal number Signal name Function

22 PCM 1 - ULA PCM Line 1 Up Link A

20 PCM 1 - ULB PCM Line 1 Up Link B

24 GND ground

21 PCM 1 - DLA PCM Line 1 Down Link A

19 PCM 1 - DLB PCM Line 1 Down Link B

23 GND ground

Tab. 2.1 Pinning of Abis-interface (OVPT 120 Ohm)

tracing interfacesfor Abis-lines( 4 x Sub-D 9 )

holes for cable fixing with straps

24pole-terminal block

1357911131517192123

24681012141618202224

Page 24: bs20is

24 A30808-X3247-G362-2-7631

IMN:BTSE BS 20 InstallationBase Transceiver Station Equipment

The Overvoltage Protection carries 4 Sub-D9 female connectors for tracingthe PCM lines.The following table shows the pinning of the tracing interfaces.

16 PCM 2 - ULA PCM Line 2 Up Link A

14 PCM 2 - ULB PCM Line 2 Up Link B

18 GND ground

15 PCM 2 - DLA PCM Line 2 Down Link A

13 PCM 2 - DLB PCM Line 2 Down Link B

17 GND ground

10 PCM 3 - ULA PCM Line 3 Up Link A

8 PCM 3 - ULB PCM Line 3 Up Link B

12 GND ground

9 PCM 3 - DLA PCM Line 3 Down Link A

7 PCM 3 - DLB PCM Line 3 Down Link B

11 GND ground

4 PCM 4 - ULA PCM Line 4 Up Link A

2 PCM 4 - ULB PCM Line 4 Up Link B

6 GND ground

3 PCM 4 - DLA PCM Line 4 Down Link A

1 PCM 4 - DLB PCM Line 4 Down Link B

5 GND ground

Pin No. Signal (x=1,2,3,4) Pin No. Signal (x=1,2,3,4)

1 PCMx-ULB 2 GND/G

3 GND/G 4 GND/G

5 PCMx-DLB 6 PCMx-ULA

7 GND/G 8 GND/G

9 PCMx-DLA

Tab. 2.2 Pinning of PCM line monitoring interface (SUB-D9,female)

terminal number Signal name Function

Tab. 2.1 Pinning of Abis-interface (OVPT 120 Ohm)

Page 25: bs20is

A30808-X3247-G362-2-7631 25

InstallationBase Transceiver Station Equipment

IMN:BTSE BS 20

2.7.5.2 Abis-Interface for 75 Ohm Cable Impedance

Fig. 2.13 OVPT with SMA connectors (75 Ohm)

For Abis cabling with 75 Ohm impedance use coaxial cable e.g.S-09YS(ST)CY 8x2x0.6/1.2.The coaxial cables will be prepared as follows:– Cut back the outer insulation(length approx. 120 mm).– Unbraid the main cable screen.– Twist and tinn the screen wires and the additional wire.– Insulate the screening with insulation sleeve.– Fix the screening at the nearest ground point.– Fix a SMA-female connector for each PCM-up and down line at the end to be

connected to the OVPT.– Connect the prepared cable to the matching connectors.– Use a torque spanner for SMA connector (35 N/cm).

Fig.2.14 shows the handling of the main cable shield.

PCM1-UL

PCM2-UL

PCM3-UL

PCM4-UL

PCM1-DL

PCM2-DL

PCM3-DL

PCM4-DL

PCM1-UL-MON

PCM2-UL-MON

PCM3-UL-MON

PCM4-UL-MON

PCM1-DL-MON

PCM2-DL-MON

PCM3-DL-MON

PCM4-DL-MON

Monitoring Interfaces for PCM lines SMA-male connectors for PCM lines fixing screws

Page 26: bs20is

26 A30808-X3247-G362-2-7631

IMN:BTSE BS 20 InstallationBase Transceiver Station Equipment

Fig. 2.14 Preparation of 75 Ohm coaxial cable

2.7.5.3 Abis-Interface without OVPTWithout OVPT (the lightning protection for 4 PCM channels), if this function is notneeded, a SUB-D25 female connector is the direct interface for the PCM links.

approx. 120 mm75 Ohm coaxial cable

cable shield

coaxial lines

main cable screen

twisted, tinned main cable screen and addition wire

additional wire

screening with insulation sleeve

Pin no. SubD 25 Signal name Function

1 PCM 1 - ULA PCM Line 1 Up Link A

14 PCM 1 - ULB PCM Line 1 Up Link B

3 GND/G shield pair 1

2 PCM 1 - DLA PCM Line 1 Down Link A

15 PCM 1 - DLB PCM Line 1 Down Link B

16 GND/G shield pair 2

4 PCM 2 - ULA PCM Line 2 Up Link A

17 PCM 2 - ULB PCM Line 2 Up Link B

6 GND/G shield pair 3

Tab. 2.3 Pinning of the Abis-interface cable without OVPT (SubD 25 connector)

Page 27: bs20is

A30808-X3247-G362-2-7631 27

InstallationBase Transceiver Station Equipment

IMN:BTSE BS 20

2.7.6 Shelter Alarm Interface - Signalling Link TerminalFor the (optional, currently not used) connection between the signalling link terminal onsite and the shelter alarm interface (SAL) at RCAP proceed in following steps:– Locate the SubD 37 connector at the rack cabling access panel.– Refer to the site-specific documentation for the required information about the

location of the signalling link terminal, the type of shielded cable and type ofconnector, which has to be used.

– Determine the real distance between rack and signalling link terminal andcut the cable for the required length.

– Fix the SubD 37 male connector at the end, which has to be connected at theserial alarm interface. The pin assignment you will find in thesite-specific documentation.

– Pay attention to the assembly instructions of the connector and thehandling instructions of the cable which are used.

– Put up the connector on the shelter alarm interface and tight thefastening screws.

For connecting the wires at the signalling link terminal refer to the sitedocumentation for the pin assignment.Type and pinning of the terminal on site are subject to change and depending on thecustomer.

The following table gives information about the pinning of the SubD 37 connector:

5 PCM 2 - DLA PCM Line 2 Down Link A

18 PCM 2 - DLB PCM Line 2 Down Link B

19 GND/G shield pair 4

7 PCM 3 - ULA PCM Line 3 Up Link A

20 PCM 3 - ULB PCM Line 3 Up Link B

9 GND/G shield pair 5

8 PCM 3 - DLA PCM Line 3 Down Link A

21 PCM 3 - DLB PCM Line 3 Down Link B

22 GND/G shield pair 6

10 PCM 4 - ULA PCM Line 4 Up Link A

23 PCM 4 - ULB PCM Line 4 Up Link B

12 GND/G shield pair 7

11 PCM 4 - DLA PCM Line 4 Down Link A

24 PCM 4 - DLB PCM Line 4 Down Link B

25 GND/G shield pair 8

13 GND/G main cable shield

Pin no. SubD 25 Signal name Function

Tab. 2.3 Pinning of the Abis-interface cable without OVPT (SubD 25 connector)

Page 28: bs20is

28 A30808-X3247-G362-2-7631

IMN:BTSE BS 20 InstallationBase Transceiver Station Equipment

2.7.7 Operator Alarm Interface - Signalling Link TerminalThe SubD 37 connector at the bottom of the rack is the access for external alarms andcommands.The Operator Alarm Interface (OAL) will be connected to the signalling link terminal onsite.For information about pinning and signal meaning refer to the following tables.

Pin no.SubD 37

signal name Pin no.SubD 37

signal name

1 envaBTSE16 pos. (free) 20 envaBTSE16 min. (free)

2 envaBTSE17 pos. (free) 21 envaBTSE17 min. (free)

3 envaBTSE18 pos. (free) 22 envaBTSE18 min. (free)

4 envaBTSE19 pos. (free) 23 envaBTSE19 min. (free)

5 no.5 positive, undefined 24 no.5 minus, undefined

6 no.6 positive, undefined 25 no.6 minus, undefined

7 no.7 positive, undefined 26 no.7 minus, undefined

8 no.8 positive, undefined 27 no.8 minus, undefined

9 no.9 positive, undefined 28 no.9 minus, undefined

10 no.10 positive, undefined 29 no.10 minus, undefined

11 no.11 positive, undefined 30 no.11 minus, undefined

12 no.12 positive, undefined 31 no.12 minus, undefined

13 no.13 positive, undefined 32 no.13 minus, undefined

14 no.14 positive, undefined 33 no.14 minus, undefined

15 no.15 positive, undefined 34 no.15 minus, undefined

16 no.16 positive, undefined 35 no.16 minus, undefined

17 no.17 positive, undefined 36 no.17 minus, undefined

18 37

19 -

Tab. 2.4 Pinning of the shelter alarm interface

Pin no.SubD 37

signal name signalmeaning

Pin no.SubD

37

signal name signal meaning

1 OPCMD1P undefined 20 OPALM6M AVV*

2 OPCMD1M undefined 21 OPALM7P STOT/ROT**

3 OPCMD2P undefined 22 OPALM7M STOT/ROT**

Tab. 2.5 Pinning of the operator alarm interface (OAL)

Page 29: bs20is

A30808-X3247-G362-2-7631 29

InstallationBase Transceiver Station Equipment

IMN:BTSE BS 20

2.7.8 Serial Interface - Signalling Link TerminalThe Serial Interface(currently not used) could be connected to the signaling link terminalon site as follows:– Refer to the site documentation for the required information about the location of the

signaling link terminal and the type of cable and connector which have to be used.– Determine the distance between rack and link terminal.– Cut the cable to the required length.– Fix the SubD 9 male connector at the end to be connected at the

serial interface of the rack.

4 OPCMD2M undefined 23 OPALM8P 48VOT/48OTB**

5 OPCMD3P undefined 24 OPALM8M 48VOT/48OTB**

6 OPCMD3M undefined 25 OPALM9P SDO/KVz

7 OPCMD4P undefined 26 OPALM9M SDO/KVz

8 OPCMD4M undefined 27 OPALM10P ACSF**/ACR***

9 OPALM1P smoke 28 OPALM10M ACSF**/ACR***

10 OPALM1M smoke 29 OPALM11P room***/heat***

11 OPALM2P water*** 30 OPALM11M room***/heat***

12 OPALM2M water*** 31 OPALM12P MBB**/BBR**

13 OPALM3P humidity*** 32 OPALM12M MBB**/BBR**

14 OPALM3M humidity*** 33 OPALM13P BCHF**

15 OPALM4P AC l.-prot.BS 34 OPALM13M BCHF**

16 OPALM4M AC l.-prot.BS 35 OPALM14P AC l._prot.

17 OPALM5P AC-warning*** 36 OPALM14M AC l._prot.

18 OPALM5M AC-warning*** 37 --

19 OPALM6P AVV* -- --

* only if equipped with AVV or microwave, ** from SSC, *** only if sensor is installed

signal name signal meaning

OPCMD_P Operator command no._, positive

OPCMD_M Operator command no._, minus

OPALM_P Operator alarm no._, positive

OPALM_M Operator alarm no._, minus

Tab. 2.6 Signal meaning, operator alarm interface

Pin no.SubD 37

signal name signalmeaning

Pin no.SubD

37

signal name signal meaning

Tab. 2.5 Pinning of the operator alarm interface (OAL)

Page 30: bs20is

30 A30808-X3247-G362-2-7631

IMN:BTSE BS 20 InstallationBase Transceiver Station Equipment

– Follow the connector assembly instructions and the handling instructions of thecable.

– Put up the connector on the Serial Interface.– Tighten the fastening screws.– Lead the cable through cable entry forward to the link terminal, fix matching wires at

the required pins. Refer to the site documentation for the pinning.

2.7.9 Interface for Local Maintenance Interface (LMT)A SubD 15 female connector, located at the top of the rack is the interface forconnecting the Local Maintenance Terminal (LMT) for commissioning andand service purposes.

2.8 Board Insert ProceduresThe BS20 will be delivered fully equipped with all modules necessary for proper func-tion.If the rack was shipped unequipped, the following equipment is designed for completionon site:– Power Amplifiers– Transceive Processor Units– Antenna Combiner– Backup Batterie– Generic Power Supplies

Pin no.SubD 9 Signal name Pin no.SubD 9 Signal name

1 OPSERCD 6 OPSERDSR

2 OPSERRXD 7 OPSERRTS

3 OPSERTXD 8 OPSERCTS

4 OPSERDTR 9 OPSERRI

5 OPSERGND --

Tab. 2.7 Pinning of the Serial Interface

SubD 15 Pin no. Signal name SubD 15 Pin no. Signal name

1 - 2 LXRDA

3 LCTSA 4 LTXDA

5 LRTSA 6 LTXCLKA

7 LRXCLKA 8 GND/G

9 LRXDB 10 LCTSB

11 LTXDB 12 LRTSB

13 LTXCLKB 14 LRXCLKB

15

Tab. 2.8 Pinning of the LMT interface

Page 31: bs20is

A30808-X3247-G362-2-7631 31

InstallationBase Transceiver Station Equipment

IMN:BTSE BS 20

– AC/DC Converter– Fan unit– HYCOM or DUKIT

The manufacturer uses code keys for easy use and to prevent the installation ofmodules at incorrect mounting positions.

Fig. 2.15 Location of code keys

Modulename

long name type of code key

BBSIG baseband and signalprocessing unit 2

MCLK master clock 1

CCTRL core controller 4

RXMUCO receive multicoupler 1

RXAMCO receiver antenna module and multicoupler 1

LI link interface 5

ALCO alarm and control board 3

GPSU generic power supply unit 4

PA power amplifier 2

DCPA direct current converter for PA 4

TPU transceiver and processor unit 1

DCTPU direct current converter for TPU 3

Tab. 2.9 Code keys of RF and core modules

codekey

codekey

levers

2

code key no.

Page 32: bs20is

32 A30808-X3247-G362-2-7631

IMN:BTSE BS 20 InstallationBase Transceiver Station Equipment

Fig. 2.16 Mounting Unit Numbering of the BS 20 rack (equipped with HYCOM andRXMUCO)

The BS 20 can also be equipped with DUKIT (DUKIT20G for D900 or DUKIT20D forD1800) and RXAMCO.The mounting position of DUKIT is identical to the HYCOM position.The RXAMCOs find place in row „F“ instead of the RXMUCOs.In case of rack extension the HYBRID module finds place in the slots of RXMUCO 2/3.

2.8.1 Installation of the AC/DC ConverterInstall the AC/DC converter as follows:– Insert the AC/DC converter into the subrack. The correct mounting position is shown

at Fig.2.16.– Tighten the fastening screws.– Connect the plug-in power supply cable with the AC input socket

(see Fig.2.17) at the front cover of the converter.– Connect the plug-in DC output cable with the DC/Alarm connector.– Tighten the fastening screws of the plug.

MUT ROW

B

CF

G

C001

C

D

E101

F

C

C002OVPT

AC

/DC

0

ALC

O 0

BB

SIG

0B

BS

IG 1

LI 0

MC

LK 0

CC

TR

L 0

PA

0

PA

1

TP

U 0

TP

U 1

GPSU 0 RX

MU

CO

0R

XM

UC

O 1

RX

MU

CO

2R

XM

UC

O 3

DC

PA

0

DC

PA

1

DC

TP

U 0

DC

TP

U 1

HYCOM or DUKIT or DUPL20R 0

Fan Unit 0

or HYBRID

Page 33: bs20is

A30808-X3247-G362-2-7631 33

InstallationBase Transceiver Station Equipment

IMN:BTSE BS 20

Fig. 2.17 Connection of the AC/DC converter

2.8.2 Installation of the Backup BatteryA frame, located inside the front door is used for mounting the battery pack.

The mounting is as follows:– Fix the front door in open position.– Unscrew the 4 crosshead screws.– Lift the battery pack inside the mounting frame. The holes of the 4 holding pieces

must match those in the mounting frame.– Fix the battery pack by the crosshead screws.

The battery pack with the AC/DC converter is connected with the red and blue wire ofthe DC/Alarm cable (see Fig.2.17.) :– Insert the prepared ends into the terminal block, located at the top of the battery

pack.– Pay attention to the correct polarity: "+" wire red ; "-" wire blue– Tighten the clamping screws.

to fuse panel(already connected)

to backplane(already connected)

wires for connectionwith internal backupbattery

frompower distribution board(already connected)

AC

DCandAlarms

DC/Alarm cable

power supplycable

Page 34: bs20is

34 A30808-X3247-G362-2-7631

IMN:BTSE BS 20 InstallationBase Transceiver Station Equipment

2.9 System Cabling

2.9.1 OverviewThe system cabling consist of connections, which must be installed on the front side ofthe rack. It depends on the different installation variants and the cell configuration of thesite. The pre-fabricated RF-cables are shipped inside the rack.

Before starting the installation procedure, refer to the site documentation and determinetypes and numbers of cables required for the complete cabling.

Fig. 2.18 Survey of cabling BS 20, equipped with HYCOM and RXMUCO

!For fixing of the semi-rigid cables to the front connectors of the RF-modules usetorque spanner 35 N/cm for SMA connectors and 100 N/cm for SMC connectors !

HYCOM PA

RCAP

RXMUCO

TPU BUS1

LI

BBSIG

MCLK

CCTRL

ALCO

BUS 2

OVPT

RXMUCOdiv.

LMTSite InputsSite Outputs

Abis

System Cabling with number of variantsother connections (preinstalled at factory)External Cabling

370-372

368/369

350-352

360-362

Backplane

RXAMOD

RXAMODdiv.

rack boundary

rack boundary

375/376

348/349

358/359

Page 35: bs20is

A30808-X3247-G362-2-7631 35

InstallationBase Transceiver Station Equipment

IMN:BTSE BS 20

Fig. 2.19 Survey of cabling BS 20, equipped with DUKIT and RXAMCO

Fig. 2.20 Survey of cabling BS 20, equipped with HYCOM, RXAMCO and RXFIL

DUKIT PA

RXAMCO

TPU BUS1

LI

BBSIG

MCLK

CCTRL

ALCO

BUS 2

OVPT

RXAMCO div

LMTSite InputsSite Outputs

Abis

System Cabling with number of variantsother connections (preinstalled at factory)External Cabling

rack boundary

rack boundary

RCAP

141-144

164,165

162,163

156-158

159-161

151,152

153-155

backplane

HYCOM PA TPU BUS1

LI

BBSIG

MCLK

CCTRL

ALCO

BUS 2

OVPT

LMTSite InputsSite Outputs

Abis

System Cabling with number of variantsother connections (preinstalled at factory)External Cabling

Backplane

rack boundary

rack boundary

RXAMCO div

RXAMCORXFIL

RXFIL

RCAP

475,476

470-472

468,469

450-452

460-462

448,449

458,459

Page 36: bs20is

36 A30808-X3247-G362-2-7631

IMN:BTSE BS 20 InstallationBase Transceiver Station Equipment

2.9.2 RCAP - RXMUCO ConnectionsThese connection cables between the RXin connectors at rack bottom and the RXinconnectors of the RXMUCOs are installed in the rack during production at the factory.The 2 cables are part of the rack cabling. Connect the RXin connector of RXMUCO asfollows:– Remove the covering, which prevents access to the rear side of fuse panel and

power distribution board.– Refer to the site specific documention for information about the required connec-

tions.– Route the required cable no. to the RXMUCO to be connected. Don`t load the

connectors while laying !– Connect the cable with the RXin connector.

2.9.3 RXMUCO - TPU connectionsPre-fabricated cables are used for connections between receiver multicoupler and thetransceive and processor unit.Both ends of these cables are provided with SMC male connectors.

The modules are connected as follows:– Refer to the site documentation for information about the numbers of the required

connection variants between RXMUCOs and TPUs.– Route the cables from the RX output of RXMUCO to the RX connector of TPU.– Connect the cable at the front-connectors of the modules.– Fix the cabel by the plastic clamps on the right side wall.– Pack the extra length of the cables below the subrack.– Fix the cover, which was removed before.

The following tables contents information about the used routing variants.

routingvariant

fromconnector

toRXMUCO

connector cable length

348 RFRX 0 0 RXI 1150 mm

349 RFRX 2 2 RXI 1150 mm

Tab. 2.10 RXin connectors - RXMUCO

routingvariant

fromconnector

toRXMUCO

connector cable length

358 RFRX 1 1 RXI 1150 mm

359 RFRX 3 3 RXI 1150 mm

Tab. 2.11 RXin connectors - RXMUCO (diversity)

Page 37: bs20is

A30808-X3247-G362-2-7631 37

InstallationBase Transceiver Station Equipment

IMN:BTSE BS 20

2.9.4 TPU - PA ConnectionsEach transceive processor unit has to be connected to the power amplifier with the samerelative number.One semiflex cable is therefore needed per installed carrier.

Proceed in the following steps:– Refer to the site-specific documentation for information about the numbers of the

required connection variants between TPUs and PAs.– Connect the cable with the TX connector of TPU and the TXin connector of PA.– Fix the cable at the front-connectors of the modules.

2.9.5 PA - HYCOM ConnectionsPrefabricated semiflex-cables are used for connections between power amplifier andHYCOM.

To connect the modules proceed in steps as follows:– Refer to the site-specific documentation for information about the numbers of the

required connection variants between PAs and HYCOMs.– Connect the cable with the TXout connector of PA and the TXin connector of

HYCOM.

routingvariant

fromRXMUCO

connector toTPU

connector cable length

350 0 RXO 0 0 RX 1100 mm

351 0 RXO 1 1 RX 1100 mm

352 2 RXO 0 1 RX 1100 mm

Tab. 2.12 RXMUCO - TPU connections

routingvariant

fromRXMUCO

connector toTPU

connector cable length

360 1 RXO 0 0 RXdiv 1100 mm

361 1 RXO 1 1 RXdiv 1100 mm

362 3 RXO 0 1 RXdiv 1100 mm

Tab. 2.13 RXMUCO (diversity) - TPU connections

routingvariant

fromTPU

connector toPA

connector cable length

368 or 162 or 468 0 TX 0 TXin 170 mm

369 or 163 or 469 1 TX 1 TXin 170 mm

Tab. 2.14 TPU - PA connections

Page 38: bs20is

38 A30808-X3247-G362-2-7631

IMN:BTSE BS 20 InstallationBase Transceiver Station Equipment

– Terminate all unused RF connectors of the HYCOM by 50 Ohm load resistors!

2.9.6 HYCOM - Backplane ConnectionsThe HYCOM has to be connected to the backplane.The necessary cables have been installed by the manufacturer during production. Theend which has to be connected to the HYCOM is provided with a 15pole connectionstrip.

Install as follows:– Refer to the site-specific documentation for information about the numbers of the

required connection variants between HYCOM and backplane.– Connect the strip with the "HYSIGN" connectors of HYCOM.– Tighten the fastening screws.– Pack the extra length of the cable in space above the subrack.

2.9.7 HYCOM - RCAP ConnectionsThese jumper leads between the RFTX connectors at rack bottom and the TXoutconnectors of HYCOM are already installed in the rack during the production at thefactory.For connection with the TXout connector of HYCOM refer to the site-specific documen-tation for information about the transmit antenna configuration and number of jumperleads, which are used.

Connect the jumper leads with the appropriate TX out connector of HYCOM.

2.9.8 DUKIT-Backplane ConnectionsBefore plug-in of the DUKIT-module into the BS 20-rack, two connections between theconnectors "VSWR 0" and "VSWR 1" at the back of the DUKITand the SubD-15 connec-tors at the backplane are needed. Install these connections as shown in Fig.2.18.

The required flat cables are contents of the DUKIT.

routingvariant

fromPA

connector to connector cable length

370 or 470 0 TXout HYCOM TXin 0 130 mm

371 or 471 1 TXout HYCOM TXin 1 130 mm

372 or 472 1 TXout HYCOM TXin 1 130 mm

Tab. 2.15 PA - HYCOM connections

routingvariant

fromHYCOM

connector to toconnector

cable length

375 0 TXout RCAP RFTX 0 900 mm

376 0 TXout RCAP RFTX 1 900 mm

Tab. 2.16 Connections between HYCOM and RFTX connectors

Page 39: bs20is

A30808-X3247-G362-2-7631 39

InstallationBase Transceiver Station Equipment

IMN:BTSE BS 20

Fig. 2.21 BS20 DUKIT connection

2.9.9 RCAP - DUKIT ConnectionsInternal jumper cables are needed for connections between the rack accesspanel at the rack bottom and the 7/16 female front connectors of the DUKIT.These jumper cables are equipped with a 7/16 angle connector at the end which will beconnected at DUKIT. A 7/16 female connector at the other end must befixed at the RCAP. These connectors are the interfaces for connecting theexternal antenna jumpers.

TX0 TX1 RXdiv1 RXdiv0Test

0 1 RX1 RX0ANT 1 ANT 0 ANTdiv 1 ANTdiv 0

connection toPA 0 and PA 1

connections to RXAMCO

VS W R 1(15pol.SubD connector)

VS W R 0(15pol.SubD connector)

VSW R-Connectors on Backplane

connecting cabels

routingvariant

from connector to connector cable length

141 RCAP RFTX 0 DUKIT 0 ANT 0 900 mm

142 RCAP RFTX 1 DUKIT 0 ANT 1 900 mm

143 RCAP RFRX 1 DUKIT 0 ANTdiv 0 1400 mm

144 RCAP RFRX 3 DUKIT 0 ANTdiv 1 1400 mm

Tab. 2.17 RCAP - DUKIT connections

Page 40: bs20is

40 A30808-X3247-G362-2-7631

IMN:BTSE BS 20 InstallationBase Transceiver Station Equipment

2.9.10 RXAMCO - TPU Connections

2.9.11 DUKIT - RXAMCO ConnectionsThese cables are connections between the front connectors at DUKIT andRXAMCO.

2.9.12 RXFIL -RXAMCO Connections

routing

variant

from connector to connector cable length

156 or 450 RXAMCO 0 RXO 0 TPU 0 RX 1100 mm

157 or 451 RXAMCO 0 RXO 1 TPU 1 RX 1100 mm

158 or 452 RXAMCO 2 RXO 0 TPU 1 RX 1100 mm

159 or 460 RXAMCO 1 RXO 0 TPU 0 RXDIV 1100 mm

160 or 461 RXAMCO 1 RXO 1 TPU 1 RXDIV 1100 mm

161 or 462 RXAMCO 3 RXO 0 TPU 1 RXDIV 1100 mm

Tab. 2.18 RXAMCO - TPU connections

routingvariant

from connector to connector cable length

151 DUKIT RX 0 RXAMCO 0 RXin 1300 mm

152 DUKIT RX 1 RXAMCO 1 RXin 1300 mm

153 DUKIT RX 1 RXAMCO 2 RXin 1300 mm

154 DUKIT RXdiv 0 RXAMCO 1 RXin 1300 mm

155 DUKIT RXdiv 0 RXAMCO 2 RXin 1300 mm

Tab. 2.19 DUKIT - RXAMCO connections

routingvariant

from connector to connector cable length

448 RXFIL RFRX 0 RXAMCO 0 RXI 900 mm

449 RXFIL RFRX 2 RXAMCO 2 RXI 900 mm

458 RXFIL RFRX 1 RXAMCO 1 RXI 900 mm

459 RXFIL RFRX 3 RXAMCO 3 RXI 900 mm

Tab. 2.20 RXFIL - RXAMCO connections

Page 41: bs20is

A30808-X3247-G362-2-7631 41

InstallationBase Transceiver Station Equipment

IMN:BTSE BS 20

2.9.13 PA - DUKIT Connections

2.10 Antenna Connections

2.10.1 OverviewFor detailed antenna configuration and connection procedures refer to the site-specificdocumentation. The following figure shows an example of the antenna cabling:

routingvariant

from connector to connector cable length

164 PA 0 TXout DUKIT 0 TX 0 550 mm

165 PA 1 TXout DUKIT 0 TX 1 550 mm

Tab. 2.21 PA - DUKIT connections

Page 42: bs20is

42 A30808-X3247-G362-2-7631

IMN:BTSE BS 20 InstallationBase Transceiver Station Equipment

Fig. 2.22 Antenna cabling BS 20 (example with HYCOM/RXMUCO)

2.10.2 Identification of Antenna Feeder CablesFor installation and service purposes it is useful to know, which hardware is connectedto which cell. The numbering, seen from the top of the antenne pole, starts at anazimuth angle of 0˚ (north) and rotates clockwise.The first existing cell which beam center line lies at 0˚ or more degree is defined ascell 0 or sector 0. The next one following in the same direction cell is cell 1 etc.In case of omni cell the cell no. is 0.

Adhesive tape in different colours will be used for identification of the antenna feedercables, which has to be connected via short jumper cables to the antenna connectors of

F

RXAMOD

transmit antennareceive antennareceive antenna(diversity)

receive path,diversity

11

2

32

4

4

5 5

6 6

4

4

7

89

10

1 connection 7-162 jumper cable 7-16 male / 7-16 female

3 jumper cable 7-16 male / 7-16 male4 grounding kit5 clamp6 antenna feeder cable7 wall gland8 EMP-protector with attenuation chip 1...9 db9 jumper cable 7-16 male / 7-16 male

10 jumper cable 7-16 male / n-male

Page 43: bs20is

A30808-X3247-G362-2-7631 43

InstallationBase Transceiver Station Equipment

IMN:BTSE BS 20

the BS20.

Fig. 2.23 Cell numbering (top view to the antenna pole)

sector width 120˚

sector angle

directional antenna

pole

sector 0

sector 1

sector 2

N

beam center line

meaning colour 1.label(nearest to connector)

colour 2. label colour 3.label

TX/RX cable red --- ---

TX/RX div. cable red --- white

sector 0 --- green ---

sector 1 --- orange ---

Tab. 2.22 Label colours of antenna feeders for BS20 with DUCOM

meaning colour 1.label(nearest to connector)

colour 2. label colour 3.label

TX cable red --- ---

Tab. 2.23 Label colours of antenna feeders for BS20 with HYCOM

Page 44: bs20is

44 A30808-X3247-G362-2-7631

IMN:BTSE BS 20 InstallationBase Transceiver Station Equipment

2.10.3 Transmit Antenna ConnectionsCoaxial jumper leads are used for connections between the antenna window and thetransmit antenna connectors RFTX 0 - 1.

The required number of jumper cables must be fabricated on site, they should be asshort as possible.

For fabrication and connecting of the jumper leads proceed as follows:– Refer to the site-specific documentation for information about the transmit antenna

configuration and the number of jumper leads.– Check the distance between the antenna feeder cables and the RFTX connector at

rack bottom.– Cut the cables to the required length.– Connect 7/16 male connectors at both ends of the jumper leads.– Route a jumper lead from each transmit antenna feeder cable on the antenna

window to the appropriate RFTX connector at the rack bottom.– Connect the jumper lead with the RFTX connector.

Note: Make sure that all antenna feeder cables entering the building areprotected by coaxial EMP protectors !

2.10.4 Receive Antenna ConnectionsCoaxial jumper leads are used to make connections from the antenna window to thereceive antenna connectors RFRX 0 - 3 at the bottom of the rack.

The required number of jumper cables must be fabricated on site, they should be asshort as possible.

For fabrication and connecting of the jumper leads proceed as described at section2.9.2. of this manual.

2.10.5 Transmit/Receive Antenna CablingOne common antenna path is used for the transmit- and receive signals.The connectors ANT 0 and ANT 1 are used for connecting the TX/RX antennas.If receive path diversity is required, the connectors ANTdiv 0 and ANTdiv 1 willbe used to connect the additional receive antennas.Prepare jumpers as described in section 2.9.2.

RX cable white --- ---

RX cable div. white --- white

sector 0 --- green ---

sector 1 --- orange ---

meaning colour 1.label(nearest to connector)

colour 2. label colour 3.label

Tab. 2.23 Label colours of antenna feeders for BS20 with HYCOM

Page 45: bs20is

A30808-X3247-G362-2-7631 45

InstallationBase Transceiver Station Equipment

IMN:BTSE BS 20

2.10.6 Identification of Antenna Feeder CablesFor later indentification of the antenna paths it is useful to mark the jumper cableswith adhesive tape. The following scheme will be suggested:

2.11 Rack ExtensionRack extension is necessary to save the antenna system and provide a 4 carrier cellwith two coupled BS20.Rack extension could be realized in case of new installation of two BS20 on site or asecond BS20 will be added to the already installed rack.The following figure gives information about the minimum site dimensions.

meaning colour 1.label(nearest to connector)

colour 2. label colour 3.label

TX/RX cable red --- ---

TX/RX div. cable red --- white

sector 0 --- green ---

sector 1 --- orange ---

Tab. 2.24 Label colours of antenna jumpers for BS20 with DUKIT

meaning colour 1.label(nearest to connector)

colour 2. label colour 3.label

TX cable red --- ---

RX cable white --- ---

RX cable div. white --- white

sector 0 --- green ---

sector 1 --- orange ---

Tab. 2.25 Label colours of antenna jumpers for BS20 with HYCOM

Page 46: bs20is

46 A30808-X3247-G362-2-7631

IMN:BTSE BS 20 InstallationBase Transceiver Station Equipment

Fig. 2.24 Minimum site dimensions for BS20 rack extension

The dimensions as shown in the figure are necessary for function and maintenance ofthe equipment on site. Additional floor space is required to provide emergency ways.

In case the racks are installed with plinth for floor mounting, a mimimum height betweenfloor and ceiling or other lowest construction part of 1700 mm is absolute required.

1/2” jumper leads are required for connecting the racks, equipped with N-type femaleconnectors at both ends.

The rack extension consist of the jumper connections as shown in the following figureand the rack-internal system cabling. Further a HYBRID module has to be installed ineach BS21. The slots of RXAMCO 2 and 3 are the mounting position for the HYBRID.BS20.

1200

1450

side by side installation

1010

back to back installation

2020

(wall mounting or floor mounting)

(floor mounting only)

Page 47: bs20is

A30808-X3247-G362-2-7631 47

InstallationBase Transceiver Station Equipment

IMN:BTSE BS 20

Fig. 2.25 Rack extension cabling

DUKIT 1:2 DUKIT 1:2

HYBRIDBG

N-connectorsin RCAP RE

BTS 1

TX/RX antenna 1Sector 0

RX0

TXTX

RXDIV TX0

RXDIV RXDIVTPU TPU PA PATX TX TXin TXin

RX RX

1/2” jumpercable with N-type femaleconnector

DUKIT 1:2 DUKIT 1:2

HYBRIDBG

RXAMCOdiv

RX 0

TXTX

RXDIV TX 0

RXDIV RXDIVTPU TPU PA PATX TX TXin TXin

RX RX

BTS 0

TX/RX antenna 1Sector 0

RXAMCOdiv

N-connectorsin RCAP

Page 48: bs20is

48 A30808-X3247-G362-2-7631

IMN:BTSE BS 20 InstallationBase Transceiver Station Equipment

The extension kit, which contains the 4 jumper cables, 2 HYBRID incl. SMA adaptersand the extension system cabling, is necessary for the implementation of rack exten-sion. The kit also contains detailed instructions to remove isolator which is mountedinside DUKIT module.Proceed in following stages:– Open the front doors of both racks.– Install in each rack one RXAMCO and the HYBRID module.– Use the N-type female connectors at the RCAP for connecting the racks with

1/2” jumper cables.– Setup the extension system cabling in both racks (see Tab.2.26).

2.12 Spare Parts for Field MaintenanceSuggested spare parts for field maintenance are::

Variantno.

from connector to connector cable length

541 RCAP RFTX 0 DUKIT ANT 0 900 mm

546 DUKIT TX 0 HYBRID TX OUT 1400 mm

548 RXAMCO 0 RXO 2 RCAP RFRX 2 800 mm

549 RXAMCO 0 RXO 3 RCAP RFRX 3 800 mm

551 DUKIT RX 0 RXAMCO 0 RXIN 1300 mm

556 RXAMCO 0 RXO 0 TPU 0 RX 1100 mm

557 RXAMCO 0 RXO 1 TPU 1 RX 1100 mm

558 TPU 0 RXDIV RCAP RFRX 0 1470 mm

559 TPU 1 RXDIV RCAP RFRX 1 1470 mm

562 TPU 0 TX PA 0 TXIN 170 mm

563 TPU 1 TX PA 1 TXIN 170 mm

564 HYBRID TX 0 PA 0 TXOUT 1150 mm

565 HYBRID TX 1 PA 1 TXOUT 1150 mm

571 RCAP RFRX 0 RCAP RE RFRX 3 1000 mm

572 RCAP RFRX 1 RCAP RE RFRX 2 1000 mm

573 RCAP RFRX 2 RCAP RE RFRX 1 1000 mm

574 RCAP RFRX 3 RCAP RE RFRX 0 1000 mm

Tab. 2.26 System cabling for rack extension

description part number

screw cage nut kit A50016-C1-A21door kit A50016-C31-A1door hinge kit A50016-C31-A11door lock kit A50016-C31-A21EMC gasket kit A50016-C31-A31

Page 49: bs20is

A30808-X3247-G362-2-7631 49

InstallationBase Transceiver Station Equipment

IMN:BTSE BS 20

2.13 Post Installation NotesAfter all installation activities are finished, any rubbish must be cleared fromsite. Remove all packing material for later recycling. Secure the site against unautho-rized access.

magnetic switch kit A50016-C31-A41air filter kit A50016-C31-A51thermostats kit A50016-C31-A61guides rail kit A50016-C31-A71DC fuses kit A50016-C31-A81AC fuses kit A50016-C31-A91DC EMI filter kit A50016-C31-A101AC EMI filter kit A50016-C31-A111switch fuse kit A50016-C31-A121DC lightning protection kit A50016-C31-A131AC lightning protection kit A50016-C31-A141diff. current switch kit A50016-C31-A151auxiliary protection kit A50016-C31-A161breakers kit A50016-C31-A171backplane kit A50016-C31-A181mounting kit for module A50016-C31-A191

description part number

Page 50: bs20is

50 A30808-X3247-G362-2-7631

IMN:BTSE BS 20 InstallationBase Transceiver Station Equipment

Page 51: bs20is

A30808-X3247-G362-2-7631 51

InstallationBase Transceiver Station Equipment

IMN:BTSE BS 20

3 AbbreviationsAC/DC AC/DC converter

ALCO alarm controller

BBSIG baseband and signalling module

BS Base Station

BSC Base Station Controller

BSS Base Station System

BTS Base Transceiver Station

BTS Base Transceiver Station

BTS base transceiver station

CCTRL core controller

DCPA direct current converter for PA

DCTPU direct current converter for TPU

DUKIT duplex combiner kit

ESD Electrostatically Sensitive Device

FAN fan unit

GPSU generic power supply

GSM Global System for Mobile Communication

HYCOM hybrid combiner

LI link interface

LMT Local Maintenance Terminal

MS Mobile Station

O&M Operation and Maintenance

OVPT over voltage protection

PA power amplifier

RCAP rack access panel

RXAMCO receive antenna module and multicoupler

RXMUCO receive antenna multicoupler

SBS Siemens Base Station System

SI serial interface

TPU transceive and processor unit

Page 52: bs20is

52 A30808-X3247-G362-2-7631

IMN:BTSE BS 20 InstallationBase Transceiver Station Equipment