TATA BSC Up Gradation Plan 1. INTRODUCTION:- ZTE is planning to implement new SW version in all the BSCs of ZTE Circel(ROWB/BIHAR&JKD/ORISSA).This upgrade will bring some new features and improve the KPI as :- a) Provide LBS function. b) Provide Intelligent shutdown function c) Support new type of RRU: RSU60E d) Improve KPI:GPRS&EDGE data throughput. BSC will be upgraded accordingly towards iBSCV6.20.614c + P003. For the compatible with BSC, minos and iTC will be upgraded also. 2 .MOP for MINOS from version 3.10.430dp002 to 3.10.450k: Please find the attachment for details steps: 3 .MOP for ITC from version 6.10.301bP002 to 6.10.400D and ITCM from version 6.10.100E to 6.10.400B:

Upload: maxiszte

Post on 29-Nov-2014

167 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: BSC Upgrade MOP 13122010

TATA BSC Up Gradation Plan

1. INTRODUCTION:-

ZTE is planning to implement new SW version in all the BSCs of ZTE

Circel(ROWB/BIHAR&JKD/ORISSA).This upgrade will bring some new features

and improve the KPI as :-

a) Provide LBS function.

b) Provide Intelligent shutdown function

c) Support new type of RRU: RSU60E

d) Improve KPI:GPRS&EDGE data throughput.

BSC will be upgraded accordingly towards iBSCV6.20.614c + P003.

For the compatible with BSC, minos and iTC will be upgraded also.

2 .MOP for MINOS from version 3.10.430dp002 to 3.10.450k:

Please find the attachment for details steps:

3 .MOP for ITC from version 6.10.301bP002 to 6.10.400D and

ITCM from version 6.10.100E to 6.10.400B:

4 .MOP for IBSC/IOMCR from version 6.20.200e to 6.614c

Backup two files under path: $OMCHOME\tmp\ftp\zdb\ibscXX. File

name is CfgTable.ZDB and DBVer.ZDB.

1.OMP ZDB backup1) Fist Log in OMP with proper user name.

2) Enter into /IDE0/DATA1 catelog

3) Use bin command to convert into binary mode, then get

same files as shown above

Page 2: BSC Upgrade MOP 13122010

4) Exit with bye command

Backup two files under path: $OMCHOME\tmp\ftp\zdb\ibscXX. File

name is CfgTable.ZDB and DBVer.ZDB.

b) Export alarm list

For the comparison of upgrade effects, we will export alarm list as

the reference.

c) A/GB status review

Page 3: BSC Upgrade MOP 13122010

All status of interface A/GB include Flex A/Flex GB/IP A/IP GB will

be checked and noted for further comparison

d) Module status reviewe) Feature status reviewf) OMP BOOT parameter review

Use the command as shown below for version check.

telnet 129.1.4.2

login:zte

password:***

MPX86_2->SCSShowVmmBootCfgInfo

OMC FTPSVR IP: 129.1.4.1

OMC FTPSVR UserName: uep

OMC FTPSVR PassWord: uep

OMC FTPSVR Config FileName: ompcfg.ini

value = 39 = 0x27 = '''

MPX86_2->exit

g) ZXG10.CFG crosscheck for OMP

Remark: uid.gid must be the same as id group in gomcr group, IP address should be the same as SBCX intranet address.

2. OMP upgradea) Remove standby OMP

b) Send ZDB to OMP

i. Remove FE link between SBCX and OMP

ii. Generate ZDB backup in client, and store in

$OMCHOME\tmp\ftp\zdb\ibscXX catelog ( XX represents iBSC

ID),iii. SBCX link recover

Enter into /DOC0/DATA1 catelog

Delete DOC0\DATA1\DBVer.ZDB file

Enter into /IDE0/DATA1 catelog

Use lcd $OMCHOME\tmp\ftp\zdb\ibscXX , switch to ZDB locale catalog

Transfer CfgTable.ZDB and DBVer.ZDB file to OMP;put CfgTable.ZDB

put DBVer.ZDB

Confirmation the file

Exit

c) Upload zxg10.cfg file

Upload zxg10.cfg /DOC0/CFG catalog in OMP;

Page 4: BSC Upgrade MOP 13122010

Attention: All OMP boards must be equipped with new version

d) Version import

Enter into version management, click“Upload version file to

OMC”,upload IBSC_MPX86_2_MP_P4_V6.20.011A_Z.BIN and IBSC_MPX86_2_RPU_P4_V6.20.011A_Z.BIN to OMP,

图 3.3-1 单个入库MP版本

e) OMP version application

Deploy CPU/FPGA version with right click on particular item,

choose “create OMP version ini file”.

Page 5: BSC Upgrade MOP 13122010

图 3.4-2 构建OMP版本

f) Reset OMP to download SW

1. After reset OMP. Version will be activated until RUN2 is flashing.

2. Query OMP for CPU(CPU1)version information.

图 3.5-3 查看OMP单板 CPU版本

If OMP can not load new version, we will use COM cable to debug OMP.

g) ZDB synchronization

Database synchronization in OMP

Page 6: BSC Upgrade MOP 13122010

h) RPU upgrade

i. Enter into BSC general version frame and update RPU version.

1. RPU will be reset to activate version.

2.Query RPU version to confirm

图 3.8-4 query RPU version in OMP

3. Another boards upgrade(includes CMP)

a) Order for upgrade:

OMP

CLKG(ICM)

UIM

CHUB

CMP

Page 7: BSC Upgrade MOP 13122010

Resource rack board

b) SW upgrade boards level

Enter into BSC general version frame, right click target version. Open update

dialog box to update the SW version.

For particular board as GLI which has more than one SW, reset only after the

final one.

图 4.2-5 update SW version information

c) Confirm SW version

For the security, all boards must be queried to confirm the proper version

has been activated.

1、open “BSC software version management”

2、click query to check:

Page 8: BSC Upgrade MOP 13122010

3、Result will be given after the query:

d) Confirmation for individual board

Query for each board for confirmation.

Page 9: BSC Upgrade MOP 13122010
Page 10: BSC Upgrade MOP 13122010

3. Emergency Fallback Procedure:

OMP roll back

1) Enter into general version management, user backup MP/FPGA version

to create OMPcfg.ini file.

2) Replace OMP with backup one

3) Reboot peripheral board

4) Check SW version

5) Reinstall OMP

iBSC transfer data to iomcr

click “from NE synchronize data to OMC” as shown below:

图 8.7-6 iBSC transfer data to iomcr

Recover data damage with backup

If data is damaged be abnormal cause, OMP can not boot up. Use telnet to

connect OMP, use put command to recover OMP

Hereby is the file list:

CfgTable.ZDB 后台备份文件

Page 11: BSC Upgrade MOP 13122010

DBVer.ZDB 后台备份文件VerTable.ZDB 前台备份文件DBVerSingle.ZDB 前台备份文件

1. Operation procedure:

Log in OMP

Delete DBVer.ZDB和 TableReg.ZDB in /DOC0/DATA1.

Delet CfgTable.ZDB 、DBVer.ZDB, VerTable.ZDB in /IDE0/DATA1

2. Upload ZDB backup file

Reset OMP after ZDB is successfully uploaded.

Page 12: BSC Upgrade MOP 13122010

Escalation-Matrix

ZTE SUPPORT ENGINEER ESCALLATION Designation Mobile NoLEVEL-1:- Swarnajyoti Mazumder BSS ENGG. 09874300615

LEVEL-2:- Sumit SinhaSUPPORT

Engg 09748499794

LEVEL-3:- Wubin/BaiyutaoR &D

08802037173

ZTE Emergency ESCALATION Designation Mobile NoLEVEL-1:- Sumit Sinha Manager 09748499794LEVEL-2:- Goutam Kundu O& M Head 08420034000

Level -3 Shakil AnwarDeputy Director 09748734025

TATA Escalation Matrix

TATA ESCALATION Designation Mobile NoLEVEL-1:- Sachin Maheta Manager 9038099500

LEVEL-2:- Monojit PalSenior

Manager

Page 13: BSC Upgrade MOP 13122010