bsc upgrade mop 13122010
TRANSCRIPT
TATA BSC Up Gradation Plan
1. INTRODUCTION:-
ZTE is planning to implement new SW version in all the BSCs of ZTE
Circel(ROWB/BIHAR&JKD/ORISSA).This upgrade will bring some new features
and improve the KPI as :-
a) Provide LBS function.
b) Provide Intelligent shutdown function
c) Support new type of RRU: RSU60E
d) Improve KPI:GPRS&EDGE data throughput.
BSC will be upgraded accordingly towards iBSCV6.20.614c + P003.
For the compatible with BSC, minos and iTC will be upgraded also.
2 .MOP for MINOS from version 3.10.430dp002 to 3.10.450k:
Please find the attachment for details steps:
3 .MOP for ITC from version 6.10.301bP002 to 6.10.400D and
ITCM from version 6.10.100E to 6.10.400B:
4 .MOP for IBSC/IOMCR from version 6.20.200e to 6.614c
Backup two files under path: $OMCHOME\tmp\ftp\zdb\ibscXX. File
name is CfgTable.ZDB and DBVer.ZDB.
1.OMP ZDB backup1) Fist Log in OMP with proper user name.
2) Enter into /IDE0/DATA1 catelog
3) Use bin command to convert into binary mode, then get
same files as shown above
4) Exit with bye command
Backup two files under path: $OMCHOME\tmp\ftp\zdb\ibscXX. File
name is CfgTable.ZDB and DBVer.ZDB.
b) Export alarm list
For the comparison of upgrade effects, we will export alarm list as
the reference.
c) A/GB status review
All status of interface A/GB include Flex A/Flex GB/IP A/IP GB will
be checked and noted for further comparison
d) Module status reviewe) Feature status reviewf) OMP BOOT parameter review
Use the command as shown below for version check.
telnet 129.1.4.2
login:zte
password:***
MPX86_2->SCSShowVmmBootCfgInfo
OMC FTPSVR IP: 129.1.4.1
OMC FTPSVR UserName: uep
OMC FTPSVR PassWord: uep
OMC FTPSVR Config FileName: ompcfg.ini
value = 39 = 0x27 = '''
MPX86_2->exit
g) ZXG10.CFG crosscheck for OMP
Remark: uid.gid must be the same as id group in gomcr group, IP address should be the same as SBCX intranet address.
2. OMP upgradea) Remove standby OMP
b) Send ZDB to OMP
i. Remove FE link between SBCX and OMP
ii. Generate ZDB backup in client, and store in
$OMCHOME\tmp\ftp\zdb\ibscXX catelog ( XX represents iBSC
ID),iii. SBCX link recover
Enter into /DOC0/DATA1 catelog
Delete DOC0\DATA1\DBVer.ZDB file
Enter into /IDE0/DATA1 catelog
Use lcd $OMCHOME\tmp\ftp\zdb\ibscXX , switch to ZDB locale catalog
Transfer CfgTable.ZDB and DBVer.ZDB file to OMP;put CfgTable.ZDB
put DBVer.ZDB
Confirmation the file
Exit
c) Upload zxg10.cfg file
Upload zxg10.cfg /DOC0/CFG catalog in OMP;
Attention: All OMP boards must be equipped with new version
d) Version import
Enter into version management, click“Upload version file to
OMC”,upload IBSC_MPX86_2_MP_P4_V6.20.011A_Z.BIN and IBSC_MPX86_2_RPU_P4_V6.20.011A_Z.BIN to OMP,
图 3.3-1 单个入库MP版本
e) OMP version application
Deploy CPU/FPGA version with right click on particular item,
choose “create OMP version ini file”.
图 3.4-2 构建OMP版本
f) Reset OMP to download SW
1. After reset OMP. Version will be activated until RUN2 is flashing.
2. Query OMP for CPU(CPU1)version information.
图 3.5-3 查看OMP单板 CPU版本
If OMP can not load new version, we will use COM cable to debug OMP.
g) ZDB synchronization
Database synchronization in OMP
h) RPU upgrade
i. Enter into BSC general version frame and update RPU version.
1. RPU will be reset to activate version.
2.Query RPU version to confirm
图 3.8-4 query RPU version in OMP
3. Another boards upgrade(includes CMP)
a) Order for upgrade:
OMP
CLKG(ICM)
UIM
CHUB
CMP
Resource rack board
b) SW upgrade boards level
Enter into BSC general version frame, right click target version. Open update
dialog box to update the SW version.
For particular board as GLI which has more than one SW, reset only after the
final one.
图 4.2-5 update SW version information
c) Confirm SW version
For the security, all boards must be queried to confirm the proper version
has been activated.
1、open “BSC software version management”
2、click query to check:
3、Result will be given after the query:
d) Confirmation for individual board
Query for each board for confirmation.
3. Emergency Fallback Procedure:
OMP roll back
1) Enter into general version management, user backup MP/FPGA version
to create OMPcfg.ini file.
2) Replace OMP with backup one
3) Reboot peripheral board
4) Check SW version
5) Reinstall OMP
iBSC transfer data to iomcr
click “from NE synchronize data to OMC” as shown below:
图 8.7-6 iBSC transfer data to iomcr
Recover data damage with backup
If data is damaged be abnormal cause, OMP can not boot up. Use telnet to
connect OMP, use put command to recover OMP
Hereby is the file list:
CfgTable.ZDB 后台备份文件
DBVer.ZDB 后台备份文件VerTable.ZDB 前台备份文件DBVerSingle.ZDB 前台备份文件
1. Operation procedure:
Log in OMP
Delete DBVer.ZDB和 TableReg.ZDB in /DOC0/DATA1.
Delet CfgTable.ZDB 、DBVer.ZDB, VerTable.ZDB in /IDE0/DATA1
2. Upload ZDB backup file
Reset OMP after ZDB is successfully uploaded.
Escalation-Matrix
ZTE SUPPORT ENGINEER ESCALLATION Designation Mobile NoLEVEL-1:- Swarnajyoti Mazumder BSS ENGG. 09874300615
LEVEL-2:- Sumit SinhaSUPPORT
Engg 09748499794
LEVEL-3:- Wubin/BaiyutaoR &D
08802037173
ZTE Emergency ESCALATION Designation Mobile NoLEVEL-1:- Sumit Sinha Manager 09748499794LEVEL-2:- Goutam Kundu O& M Head 08420034000
Level -3 Shakil AnwarDeputy Director 09748734025
TATA Escalation Matrix
TATA ESCALATION Designation Mobile NoLEVEL-1:- Sachin Maheta Manager 9038099500
LEVEL-2:- Monojit PalSenior
Manager