bs_gb

2
PE 100 SDR 11 Maximal zulässiger Betriebsdruck 16 bar (Wasser)/10 bar (Gas) FRIALEN ® FRIALEN-Data Sheet No. 22/00 · Update 12/00 Please turn over for important information regarding application of FRIALEN ® -Installation kit BS FRIALEN ® -Installation kits BS for Ball Valves and Tapping Ball Valves (Standard and Top-Loading) H d SW d H in m Order Ref. Stock- VE PE SW Weight status kg/each 32-50 0.45 - 0.7 T-615 741 1 1 42 30 2.620 32-50 0.6 - 1.0 T-615 957 1 1 42 14 1.700 32-50 0.6 - 1.0 T-615 328 1 1 42 30 3.140 32-50 1.0 - 1.5 T-615 330 1 1 42 30 3.920 32-50 1.2 - 2.0 T-615 329 2 1 42 30 4.800 63-200 0.6 - 1.0 T-615 958 1 1 42 14 1.700 63-200 0.6 - 1.0 T-615 310 1 1 42 30 3.730 63-200 1.0 - 1.5 T-615 331 1 1 42 30 4.760 63-200 1.2 - 2.0 T-615 311 2 1 42 30 5.990

Upload: thermosol5416

Post on 11-Feb-2016

212 views

Category:

Documents


0 download

DESCRIPTION

gasna oprema

TRANSCRIPT

Page 1: BS_GB

PE 100 SDR 11Maximal zulässiger Betriebsdruck 16 bar (Wasser)/10 bar (Gas) FR

IALE

FRIALEN-Data Sheet No. 22/00 · Update 12/00

Please turn over for important information regarding application of FRIALEN®-Installation kit BS

FRIALEN®-Installation kits BS for Ball Valves andTapping Ball Valves(Standard and Top-Loading)

H

d

SW

d H in m Order Ref. Stock- VE PE SW Weightstatus kg/each

32-50 0.45 - 0.7 T-615 741 1 1 42 30 2.62032-50 0.6 - 1.0 T-615 957 1 1 42 14 1.70032-50 0.6 - 1.0 T-615 328 1 1 42 30 3.14032-50 1.0 - 1.5 T-615 330 1 1 42 30 3.92032-50 1.2 - 2.0 T-615 329 2 1 42 30 4.80063-200 0.6 - 1.0 T-615 958 1 1 42 14 1.70063-200 0.6 - 1.0 T-615 310 1 1 42 30 3.73063-200 1.0 - 1.5 T-615 331 1 1 42 30 4.76063-200 1.2 - 2.0 T-615 311 2 1 42 30 5.990

Page 2: BS_GB

PE 100 SDR 11Maximal zulässiger Betriebsdruck 16 bar (Wasser)/10 bar (Gas)

FRIALEN®-Installation kits BS for Ball Valves andTapping Ball Valves(Standard and Top-Loading)

FRIALEN-Data Sheet 22/00 · Update 12/00

Areas of Application Telescopic actuating linkage foroperation of the FRIALEN® KHP, AKHPund AKHP-TL from the valve cover.

Assembly InstructionsBefore fusion the FRIALEN®-KHP,AKHP and AKHP-TL must be lined upto suit the tpye of actuation intended,in order to ensure that the installationkit BS will seat correctly.

Eight good reasons for usingthe FRIALEN®-Installationkits BS

● Stepless adjustment in the statedrange (pipe cover H) without theuse of tools, even in the installedstate

● Self supporting in any extendedposition

● Safe from being pulled out

● Corrosion proof

● Telescope assembly set can beadjusted even once in place andfilled

● Constructive harmonizing of thetransferable torque onto theFRIALEN®-Ball Valve

● Connection pins made fromstainless steel

● Coloured marking disk for usewith gas and water.

For further information, please call our FRIALEN®-customer service staff and specialist advisers.

2165

e/1/

?

FRIATEC Aktiengesellschaft · Technical Plastics DivisionP.O.B. 71 02 61 · D-68222 Mannheim Telephone +49 621 486-0 · Telefax +49 621 479196www.friatec.de · E-Mail: [email protected]

Please find our datasheets for

downloading on the internet at

www.friatec.de