btn instructions v1[1][2] - venture lighting europe · important information alified electrician....
TRANSCRIPT
IMPORTANT INFORMATION
alified electrician.
The standard warranty offered with these LED products as displayed at -centre/warranty can
be
This product cannot be serviced; there are no serviceable parts inside and the product should not be opened unless instructed be
mechanical fixing.
The LEDs in the luminaire are not replaceable and the casing should not be opened. When the LEDs reach end of life the whole luminaire shall be replaced.
For emergency versions, connect battery before first use.
① ② ③
④
1200mm/1500mm/1800mm
60mm 70mm
②
①
③
305mm
L1
L2
N
LsLp
L2/Ls Switched Live
L1/Lp Permanent Live*
Earth
NeutralN
* Only used in -EM Variations
DALI / N
Neutral
Earth
Live
N
3
1
2DALI / L
L1
L2
N
LsLp
L2/Ls Switched Live
L1/Lp Permanent Live
Earth
NeutralN
L1
L2
N
DALI / N
DALI / L
Not Used
Not Used
DALI (Switch Dim) & Emergency
For Switch Dim wiring, connect a permanent live to L1 and wire supply from retractive switch (push to make) to DALI / L. Also link between N and DALI / N.
Standard / Emergency DALI
Email: [email protected] Phone: +44 (0) 1923 692600 Web: www.venturelightingeurope.com
DALI / N
Neutral
Earth
Live
N
3
1
2DALI / L
Switch Dim
⑤
(Permanent Live)
(Switched Live)
Switched Live supplied from push to make retractive switch.
Wiring Instructions