build interior walls and ceilings faster using drylining ... · build interior walls and ceilings...
TRANSCRIPT
Build interior walls and ceilings faster using drylining methodsKnauf Wetroom Solutions with AQUAPANEL® Technology Inside
Be certain, choose AQUAPANEL®
Knauf Wetroom Solutions | Installation
2
KNAUf WEtroom SoLUtioNS With AQUAPANEL® tEchNoLogy iNSidE: improved performance with lower costs and installation timeKnauf Wetroom Solutions with AQUAPANEL® Technology
Inside are the more economical, sustainable and high-
performing solution to tile backing in wet or damp areas.
Constructed from aggregated Portland cement with coated
glass fibre mesh embedded surfaces, these unique cement
boards are 100% water-resistant and resistant to mould
and mildew. Knauf Wetroom Solutions enable installers to
avoid the time-consuming methods necessary with brick and
mortar; and they can do it with greater flexibility and the
ability to contend with specific needs such as extra moisture
protection or sound insulation.
www.AQUAPANEL.com
_ 32
g i v E S P A c E Give space to more room with Knauf wetroom solutions. it’s an invitation to raise the roof of possibility with a wall system that gives space to new ways of thinking and smarter ways of building. Be limited only by your ambition, not the materials you use.
See additional documentation for more detailed information on Knauf Wetroom Solutions
Technical solutions forinterior walls and ceilingsKnauf Wetroom Solutions with AQUAPANEL® Technology Inside
Be certain, choose AQUAPANEL®
Knauf Wetroom Solutions | Techniques
A better way to build interior walls and ceilingsin wet and humid areasKnauf Wetroom Solutions with AQUAPANEL® Technology Inside
Be certain, choose AQUAPANEL®
Knauf Wetroom Solutions | Systems
coNtENtSProduct range __________________________________ 4
Processing/handling ____________________________ 22
Installation of Knauf Wetroom Solutions with AQUAPANEL® Technology Inside _________________ 23
Surface finishing _______________________________ 25
Installation details ______________________________ 34
Ceiling installation _____________________________ 36
Tool recommendations __________________________ 43
Reference of additional documentation ____________ 45
4
Interior walls/ceilingsProduct range
AQUAPANEL® Maxi Screws have been specially developed for fixing AQUAPANEL® Cement Board Indoor onto frameworks of differing thicknesses. Both needlepoint and drill point versions with countersunk are available. AQUAPANEL® Maxi Screws can be used for both wall and ceiling applications in
interior and exterior applications. Screws have a special corrosion-proof coating, which gives a guaranteed 720 hours corrosion resistance in a salt spray test.
Packaging:SN 39: 500 pieces/carton SN 25: 1000 pieces/cartonSN 55: 250 pieces/cartonSB 39: 250 pieces/cartonSB 25: 250 pieces/carton
Collated screws available on request.
AQUAPANEL® maxi Screws
Fastening
Metal framework Timber framework
Metal thickness 0.6 – 0.7 mm Metal thickness 0.8 – 2.0 mm
Single layer Double layer Triple layer Single layer Double layer Single layer Double layer
AQUAPANEL® Maxi Screw SN 25 ✓
AQUAPANEL® Maxi Screw SN 39 ✓ ✓ ✓
AQUAPANEL® Maxi Screw SN 55 ✓ ✓
AQUAPANEL® Maxi Screw SB 25 ✓
AQUAPANEL® Maxi Screw SB 39 ✓ ✓
AQUAPANEL® cement Board indoorAggregated Portland cement board with coated glass fibre mesh embedded in back and front surfaces. The ends are square cut and the edges reinforced and finished smoothly (EasyEdge™).
Thickness: 12.5 mmWidth: 900 mmLength: 1200, 2400, 1250, 2500 mmWeight: approx. 15 kg/m2
Packaging: 1200/1250 mm length: 50 pieces/pallet 2400/2500 mm length: 25 pieces/pallet Building material category: A1
Lining
_ 54
Approved accessories: Walls
AQUAPANEL® Joint Adhesive (PU)AQUAPANEL® Joint Adhesive (PU) is used to bond individual AQUAPANEL® Cement Board Indoor panels.
Coverage: approx. 50 ml/m2 (approx. 6.5 m2 per cartridge)Packaging:310 ml/cartridge20 cartridges/carton
AQUAPANEL® Board Primer
AQUAPANEL® Board Primer is a ready-to-use synthetic dispersion for priming AQUAPANEL® Cement Board Indoor panels to provide maximum adhesion of tiles and plasters.
Coverage: approx. 40 - 60 g/m2 Dilution: 1: 2 with waterPackaging: 15 l/bucket2.5 l/bucket
AQUAPANEL® Q4 finish
AQUAPANEL® Q4 Finish is a ready-to-use and water-repellent skim coat for high-quality finely finished surfaces up to Q4 standard.
Application: Above the tiled area or as an all-over skim coating over AQUAPANEL® Joint Filler & Skim Coating – white & AQUAPANEL® Interior Reinforcing Mesh.
Coverage: approx. 1.7 kg/m2/mm coating depthPackaging: 20 kg/bucket
Note: For joint reinforcement, use Knauf glass fibre cover strips.
AQUAPANEL® Joint filler & Skim coating – white
AQUAPANEL® Joint Filler & Skim Coating – white is a cement-bound material for skim coating AQUAPANEL® Cement Board Indoor beyond the tiled area. AQUAPANEL® Reinforcing Mesh must be embedded.
Coverage: approx. 3.5 kg/m2 Minimum layer thickness 4 mmPackaging: 10 kg/bag
Note: Machine processing is possible with PFT RiTMO (230V)(A3-2L pump unit, SWiNG sprayer, LK 402 air compressor)
6
AQUAPANEL® Traverses are used for attaching light console loads to walls constructed from AQUAPANEL® Cement Board Indoor.
Axis frame dimensions: 600/625 mmHeight: approx. 290 mmPlate thickness: 0.75 mm with special corrosion protection layer
M type: Without impregnated wood packingMH type: With core-impregnated MDF filler, approx. 18 mm thick
AQUAPANEL® traverse
Additional accessories
Interior walls/ceilingsProduct range
AQUAPANEL® Access doors
AQUAPANEL® Access Doors can be installed in partition and plumbing walls as well as in ceilings.
Type 1:AQUAPANEL® Access Door Splash Water Protection
Type 2:AQUAPANEL® Access Door Humid Rooms
Sizes: 300 x 300 mm400 x 400 mm, 500 x 500 mm
Other sizes (e.g. tile dimension) available on request.
Please indicate application details when ordering.
AQUAPANEL® reinforcing meshAQUAPANEL® Reinforcing Mesh is a glass fibre fabric used to reinforce AQUAPANEL® Joint Filler & Skim Coating – white.
Coverage: approx. 1.1 m2/m2 Packaging:100 cm wide roll, 50 m long30 rolls/carton
_ 76
AQUAPANEL® Board Primer is a ready-to-use synthetic dispersion for priming AQUAPANEL® Cement Board Indoor panels to provide maximum adhesion of tiles and plasters.
Coverage: approx. 40 - 60 g/m2 Dilution: 1: 2 with waterPackaging: 15 l/bucket2.5 l/bucket
AQUAPANEL® Board Primer
AQUAPANEL® tapeAQUAPANEL® Tape is a glass fibre tape with an alkali-resistant coating. AQUAPANEL® Interior Tape is used to reinforce joints in interior ceiling applications. It is embedded into the AQUAPANEL® Joint Filler
– grey or AQUAPANEL® Joint Filler & Skim Coating – white.
Coverage: approx. 2.1 m/m2
Packaging:10 cm wide roll, 50 cm long20 rolls/carton
AQUAPANEL® Joint filler – grey
AQUAPANEL® Joint Filler – grey is a cement-bound filling material for setting AQUAPANEL® Tape for ceiling applications.
Coverage: approx. 0.7 kg/m2
Packaging: 10 kg/bag
Approved accessories: Ceilings
8
Interior ceilingsProduct range
AQUAPANEL® reinforcing mesh
AQUAPANEL® Reinforcing Mesh is a glass fibre fabric used to reinforce AQUAPANEL® Joint Filler & Skim Coating – white.
Coverage: approx. 1.1 m2/m2
Packaging:100 cm wide roll, 50 m long30 rolls/carton
AQUAPANEL® Q4 finish
AQUAPANEL® Q4 Finish is a ready-to-use and water-repellent skim coat for high-quality finely finished surfaces up to Q4 standard.
Ceiling use: Only use as all-over white skim coat on top of AQUAPANEL® Joint Filler & Skim Coating – white and AQUAPANEL® Reinforcing Mesh.
Coverage: approx. 1.7 kg/m2/mm coating depthPackaging: 20 kg/bucket
gLASS fiBrE JoiNt covEriNg StriP
GLASS FIBRE JOINT COVERING STRIPS are used to reinforce interior joints and to avoid cracks. It can be embedded in gypsum fillers and AQUAPANEL® Q4 Finish.
Width: 50 mmLength: 25 m/rollPackaging: 40 rolls/carton
AQUAPANEL® Joint filler & Skim coating – whiteAQUAPANEL® Joint Filler & Skim Coating – white is a cement-bound material for skim coating AQUAPANEL® Cement Board Indoor beyond the tiled area. AQUAPANEL® Reinforcing Mesh must be embedded.
Coverage: approx. 3.5 kg/m2
Minimum layer thickness 4 mmPackaging: 10 kg/bag
Note: Machine processing is possible with PFT RiTMO (230V)(A3-2L pump unit, SWiNG sprayer, LK 402 air compressor)
_ 98
Interior walls + Interior ceilingsProduct range
Air-tightness accessories
Self-adhesive sealant tape which is paper-based. For use in interior applications to bond overlapping layers.
Width: 60 mm Length: 40 m Thickness: 0.35 mmPackaging: 8 rolls/carton
LdS Soliplan
LdS Solifit/ LdS Solitwin
Self-adhesive sealant tape which is reinforced polyethylene-based with either full surface or half- surface covering paper. For exterior applications where it is used as an elastic sealant for corners, windows and openings.
Width: 60 mm Length: 25 m Thickness: 0.28 mmPackaging: 10 rolls/carton
LdS 100 (vapour barrier)Vapour control layer made from polypropylene special foil, LDS 100 is resistant to aging (sd-value ≥ 100m). Conforms to EN 13859 and ETAG 007.
Width: 2 m or 4 mLength: 50 m or 25 m10 m2/rollPackaging: 46 or 100 rolls/pallet
LdS 2 Silk (vapour barrier)
Vapour control layer made from polypropylene spunbonded fabric, LDS 2 Silk is resistant to aging and is resistant to tearing (sd-value ≥ 2m). Conforms to conforms to EN 13984 and ETAG 007.
Width: 1.50 m or 2 m Length: 50 m m2/roll: 75 m2 or 100 m2
Packaging: 20 rolls/pallet
10
Interior walls + Interior ceilingsProduct range
_ 1110
The ideal interior lining for Knauf Wetroom Solutions for damp rooms in living areas where there is occasional exposure to water spray. Boards remain impervious to moisture and create an even surface for
untiled areas. They are ideal for painting or for further surface finishing (with appropriate sealing for gaps, edges and surfaces).
Width: 1250 mmLength: 2000/2500/2600/3000 mmThickness: 12.5 mmWeight: 10.2 kg/m2
Number of boards: 50Net weight per pallet: min. 1275/max. 1912.5 kg
impregnated gypsum Board
gypsum BoardThe ideal standard interior lining for Interior Walls. It offers an economic building solution and is ideal for all types of living spaces without additional requirements.
Width: 1250 mmLength: 2000/2500/2600/2750/3000 mmThickness: 12.5 mmWeight: 9.2 kg/m2
Number of boards: 50Net weight per pallet:min. 1150/max. 1725 kg
massivbauplatte
The ideal interior lining for Knauf Wetroom Solutions where a robust solution is required. Especially suited to shaft wall construction.
Width: 625 mmLength: 2000/2500/2600 mmThickness: 25 mmWeight: 21 kg/m2
Number of boards: 20Net weight per pallet: min. 525/max. 682.5 kg
diamant
The ideal interior lining for Knauf Wetroom Solutions where higher mechanical surface resistance is required. This higher density impregnated fire-rated board also achieves a higher sound insulation than standard boards with the same system build-up.
Width: 1250 mmLength: 2000/2500 mmThickness: 12.5 mmWeight: 13.5 kg/m2
Number of boards: 40Net weight per pallet: min. 1350/max. 1687.5 kg
Lining with Gypsum Board
12
Interior walls + Interior ceilingsProduct range
The ideal interior lining for Knauf Knauf Wetroom Solutions where high fire protection requirements are critical. This special board with glass fleece coating is used for fire-rated linings. In general, the planking thickness is lower compared with standard
carton-coated Gypsum Board. An impregnated version is available: Impregnated Fireboard.
Width: 1250 mmLength: 2000 mmThickness: 12.5 mmWeight: 10.7 kg/m2Number of boards: 50Net weight per pallet: min. 1337.5 kg
fireboard
vidiwall gypsum fibre BoardThe ideal interior lining for Knauf Wetroom Solutions where higher mechanical surface resistance is required. (Performance is comparable to Diamant Hard Gypsum Board, however, board is not impregnated.)
Width: 1250 mmLength: 2000/2540/2570/3000 mmThickness: 12.5 mmWeight: 14.8 kg/m2Number of boards: 40Net weight per pallet: min. 1480/max. 2220 kg
The ideal interior lining for Knauf Wetroom Solutions where high sound reduction is key. Heavier than Diamant Hard Gypsum Board.
Width: 625 mmLength: 2000/2500 mmThickness: 12.5 mmWeight: 17.5 kg/m2
Number of boards: 42Net weight per pallet: min. 918.75/max. 1148.44 kg
Silentboard
_ 1312
Product range
Fastening of Gypsum Board
drywall ScrewHigh quality screws for dry lining with Gypsum Boards on metal frameworks (metal thicknesses up to 0.7 mm). For single/double/triple layer (depending on length). Suitable for fire-resistant and sound insulating walls.
Length: 25/35/45/55 mmScrew head diameter: 3.5 mm
Packaging: TN 3.5 x 25, 250 pieces/cartonTN 3.5 x 25, 1000 pieces/cartonTN 3.5 x 35, 250 pieces/cartonTN 3.5 x 35, 1000 pieces/cartonTN 3.5 x 45, 250 pieces/cartonTN 3.5 x 45, 1000 pieces/cartonTN 3.5 x 55, 1000 pieces/carton
This gypsum-based powdery material is used for filling joints of drywall systems and is applied by hand. It contains suspending agents and mineral fillers for application range. It is used for hand filling of Knauf Boards with joint tape on paper covered edges, preferably Joint Tape Kurt.
Packaging:25 kg bag40 bags/pallet
fUgENfüLLEr LEicht
UNifLottUNIFLOTT is the standard gypsum compound that is used for filling joints of drywall systems and is applied by hand. This special gypsum-based, synthetic-tempered, powdery material contains mineral filler and additives for easy application.
It is used for filling of Gypsum or Composite Boards with HRK (half-rounded edge) or HRAK (half-rounded tapered edge) without joint tape (except cut edge).
Packaging:25 kg/bag42 bags/pallet
triAS
TRIAS is a gypsum compound that is used for filling joints of drywall systems and is applied by hand. It is adjusted to the colour of the Gypsum Boards and has a reduced absorption after hardening. TRIAS shows extremely low shrinkage when drying. This special gypsum-
based, synthetic-tempered, powdery material contains additives for easy application. It is used for hand filling of Gypsum Boards or Composite Boards with HRK (half-rounded edge) or HRAK (half-rounded tapered edge) without joint tape on paper covered edges.
Packaging:25 kg bag42 bags/pallet
Joint compounds and plasters for Gypsum Board
14
Product range
READyGIPS consists of synthetic dispersion as binder and an exactly set up combination of particle-sized mineral calcium sulphate extenders and suspending agent. It is used for indoor skimming of Gypsum
Boards. READyGIPS is very easy to sand and produces a very fine surface after drying. For hand filling or machine filling in combination with Joint Tape Kurt.
Packaging:Pail:20 kg pail24 pails/palletBag:25 kg bag12 bags/pallet
rEAdygiPS
EASyPUTz decorative plaster is a pure mineral plaster which can be used to create a structural finish for indoor rooms on top of Gypsum Board. It is ready-made, solvent-free, free of preservatives and perfectly mixed for optimal processing characteristics.
EASyPUTz is available with 0.5 mm and with 1 mm grain and can be applied by pump or by hand. Many colour variants are possible as it can be pigmented with COMPACT-COLOR.
Packaging: 20 kg pail24 pails/pallet
EASyPUtz
JoiNtfiLLEr SUPEr
JOINTFILLER SUPER is used for joint filling in combination with Joint Tape KURT and for full-surface skim coating also in combination with UNIFLOTT. It contains organic binders and a balanced combination of
suspending agents and mineral fillers and experiences very little shrinkage when drying. JOINTFILLER SUPER can be applied by hand or by machine.
Packaging:20 kg bag42 bags/pallet
mULti-fiNiSh/mULti-fiNiSh m
MULTI-FINISH is a synthetic modified, gypsum-based filling compound and thin plaster. It is suitable for interior applications such as efficient filling of uneven and coarse surfaces, holes and slots. MULTI-FINISH is particularly suitable for the creation of surfaces which comply with
surface quality level Q4. In addition, MULTI-FINISH is suitable for the creation of premium interior coloured decorative surface design.
MULTI-FINISH M is a machine-applied filling compound and is exclusively applied using the
PFT RITMO powercoat.
Packaging:25 kg bag42 bags/pallet
_ 1514
FLÄCHENDICHTBAND is a 12 cm-wide, stretchy polyester fabric with an integrated 7 cm-wide, elastic, grained, blue central strip providing a waterproof coating.
fLächENdichtBANd
Joint tape KUrtJoint Tape KURT is a 50 mm wide strip of special paper which is used to reinforce the joint filling and edges of Gypsum Boards and Gypsum Fibre Boards. Particulary resistant to tearing.
Width: 50 mmLength: 25 m/roll, 75 m/roll
fLächENdicht
FLÄCHENDICHT is a liquid sealant comprising synthetic latex and mineral fillers. As it dries, it forms a waterproof, elastic seam.
16
Interior walls + Interior ceilingsProduct range
PUTzGRUND is a synthetic resin dispersion filled with fine quartz sand, white pigmented and alkali-resistant. It is used for interior priming on Gypsum Boards before plastering and pre-treatment of absorbent and non-absorbent substrates.
Packaging: 20 l pail24 pails/pallet
PUtzgrUNd
tiEfENgrUNdTIEFENGRUND is a smooth water-based dispersion of synthetic resins which is used to improve adhesion of finishing layers such as paint, plaster or tile adhesive for tiling. It is the standard primer for regular absorbent substrates.
Packaging:15 l pail24 pails/pallet
SPEziALgrUNd
SPEzIALGRUND is a mineral-filled, white pigmented synthetic dispersion which is used to improve adhesion of finishing layers such as paint, plaster or tile adhesive for tiling. It is formulated
for smooth and porous surfaces (i.e. non absorbent and strongly absorbent substrates. When smoothed, it creates a surface finishing without visible pores.
Packaging: 20 l pail24 pails/pallet
Priming of Gypsum Board
_ 1716
Illustrator grid gebruiken1 omhoog = 2 naar rechts
Metal profiles – wallsProduct range
Knauf Wetroom Solutions with AQUAPANEL® Technology Inside are constructed with a corrosion-resistant metal framework. Knauf offers a full range of profiles and geometries to suit all applications. Knauf metal profiles are precision-engineered, high-quality steel sections.
For standard applications, profiles from 0.6 mm to 1 mm thickness are sufficient
Profiles of 1 mm or higher thickness should be used for higher demands
Corrosion-resistant metal profiles and accessories
c and cW profiles
For vertical placement between UW profile rails of substructures for Knauf Wetroom Solutions
Corrosion-resistant Can also be used for exterior constructions.
UW profiles
Horizontal profile rails for floor and ceiling to place C and CW profiles of substructures for Knauf Wetroom Solutions
Corrosion-resistant Can also be used for exterior constructions.
UA profiles and angle connections
Higher thickness profiles For vertical placement between UW profile rails of substructures
for Knauf Wetroom Solutions For higher statics and loading requirements Corrosion-resistant Can also be used for exterior constructions.
18
Illustrator grid gebruiken1 omhoog = 2 naar rechts
Metal profiles – wallsProduct range
hat profiles
For direct application on existing surface For renovation projects For constructions with limited space requirements.
Additional profiles
To reinforce corners For curved wall applications;
for interior use.
decoupling tape
Self-adhesive tape for decoupling UW and CW profiles that are connected to other building elements (walls, columns, ceilings) so that sound and thermal bridges can be reduced.
Thickness: 3.2 mmWidth: 30/50/70/95 cmRoll length: 30 m
_ 1918
Metal profiles – ceilingsProduct range
Profiles
CD 60/27 Ceiling substructure as support and basic profile For interior and exterior ceilings Corrosion resistant Connected with cross connectors
UA profiles and angle connections as base section
Suspensions
c. b. a.
connector
Cross connectors For connection of basic and bearing profiles
a. Nonious Stirrupb. Nonious Hanger Bottomc. Direct suspension (Direktabhänger)
20
InsulationProduct range
Knauf Insulation glass mineral wool with ECOSE® Technology meets the highest demands for thermal and sound insulation in buildings. Insulating materials are made from naturally occurring and / or recycled materials and bound with ECOSE® Technology, a binding
agent, free of formaldehyde, phenol and acrylic. They are non-combustible, diffusion-open and resistant to aging. Thanks to their compaction and low weight they are easy to lift and transport. Knauf Insulation glass wool conforms to EN 13162 standard.
Glass mineral wool
Knauf Insulation Partition Wall Slab TP 115: MW EN 13162 T4-WS-WL(P)-AFr5
Knauf Insulation Partition Wall Slab TW: MW EN 13162 T4-WS-WL(P)-AF10
Covered with black-coloured glass mat on one side.
Knauf Insulation Partition Wall Roll TI 140 T: MW EN 13162 T2-AF5
Covered with light-coloured glass mat on one side.
Knauf Insulation stone mineral wool insulation materials meet the highest demands for thermal, sound and fire protection in buildings. Insulating materials are non-combustible and resistant to deformation
and aging. Stone wool insulation materials are heavier than glass wool insulation products due to the higher dry density. Knauf Insulation mineral wool conforms to EN 13162 standard.
Stone mineral wool
KD 035 Core insulating board: MW EN 13162 T4-WL(P)
KP 035 Clamping board: MW EN 13162 T4-AF5
DPF 50 Fire insulating board: MW EN 13162 T4-AF5
FPL 035 Fire insulating board: MW EN 13162 T4-AF5
_ 2120
Processing/handling
Always carry the boards upright, or use board rollers. Handle with fork lift or crane as palletted goods. Take care not to damage corners and edges when setting the boards down! Place boards down on their long edge before laying them flat.
Boards
Transportation and storage
ProfilesProtect profiles from moisture and weathering before they are installed. Products should not be left permanently exposed to the elements.
Use a pallet to support the boards when using mechanical handling equipment. Ensure that the base is strong enough to support the boards.
Protect boards from moisture and weathering before they are installed. Boards which have become damp must be dried on both sides on a flat surface prior to fitting.
Before installing, condition the boards to the ambient temperature and humidity. The ambient air and component temperatures may not be below +5°C. Do not apply joint fillers, basecoat or finishing materials in temperatures less than +5°C.
insulation
Insulation materials are supplied enclosed in polythene which is designed for short term protection only. For longer term protection on site, the product should be stored either indoors, or under cover and off the ground. Installation instructions are on every pack. Products should not be left permanently exposed to the elements.
health and safety
Observe the recommendations regarding the handling and storage of materials given earlier in this section. Consult the appropriate product data sheets and material safety data sheets. In addition the following notes are offered for guidance:
Avoid unnecessary dust on job site when using electrical saw. Keep sanding and other dust generation to a minimum. Maintain adequate ventilation and/or wear suitable protection.
Exercise care when using power tools and take all necessary precautions.
Follow instructions on packaging when applying system accessories. When using powdered products, mix with water in well-ventilated
conditions. Avoid contact with eyes and skin. In the event of contact with the eyes, irrigate with plenty of clean water immediately.
When handling insulation or cutting boards which contain glass-fibre, wear suitable protection including face mask and gloves. Wear protective glasses when working overhead.
Follow national health and safety regulations at all times.
A full range of product and safety information sheets are available upon request.
22
Processing/handling
Mark the desired shape or opening on the board with pencil and ruler. Use a knife to score the board on one side along the line so that the mesh or thick paper is cut. Snap the scored edge and cut the mesh/paper on the rear side.
Boards
Formatting/cut-outs
ProfilesCut profiles up to 0.7 mm thickness using manual or electrical scissors or use an electrical circular saw with special metal blade. When cutting corrosion-resistant profiles, make sure the cut edges are recoated with appropriate material.
Metal thicknesses bigger than 0.7 mm cannot be cut by scissors. Electric separating tools need to be used. The tool has to be selected according to the coating system. This is especially important for lacquers and other organic coatings, which are damaged by the influence of temperature and flying sparks. The use of a band saw is highly recommended.
For special cut-outs e.g. for pipes, services, only use special pre-fabricated slots as available in the profiles.
For sharp-edged cuts, for example, exterior edges, use a hand-held circular saw with a dust extractor or a pendulum jigsaw. Use of a carbide or diamond-tipped saw blade is recommended.
To make cut-outs for wiring and pipes, use a jigsaw or keyhole saw. The diameter of the opening should be approximately 10 mm greater than the diameter of the pipe. The remaining gap can be closed with a cuff, suitable sealant or sealing strip.
insulation
Insulation materials are easy to handle and install, being lightweight and easily cut to size, where necessary using an appropriate knife on flat surface to cut. To minimise thermal bridges insulation should fill the complete stud spaces. Do not use small pieces.
_ 2322
≥15 mm
≤250 mm
1.1 AQUAPANEL® Cement Board Indoor can be mounted on a wall framework made from either metal or wooden profiles.
1.2 The connection profile on either side must be coated with partition wall putty or sealing tape. Rotary pin dowels or other fasteners are used to secure the profiles to the walls.
1.3 Mark out the path of the AQUAPANEL® Cement Board Indoor wall. All runners are fastened to the floor and ceiling. Profiles are cut to length and then spaced 62.5 (60) cm apart. Set and align these profiles with the floor and ceiling profiles. Connect the wall connection studs to the end walls on either side.
1. create substructure
Align the first AQUAPANEL® Cement Board Indoor panel along the profiles. Ensure that the board is aligned correctly horizontally and vertically using
2. Align the board
Screw spacing ≤ 250 mm.Spacing from edge ≥ 15 mm.
Screws should not be overtightened.
Note: Please observe a gap of 3 – 5 mm between the boards.
4. clean the edge of the board
In order to ensure a good connection with AQUAPANEL® Joint Adhesive (PU), clean the edges of the board using, for example, a wet brush.
5. Apply the joint adhesive
5.1 Apply AQUAPANEL® Joint Adhesive (PU).
3. fastening with screws
Fasten AQUAPANEL® Cement Board Indoor to the framework with AQUAPANEL® Maxi Screws. First fasten the screws into the centre of the cement boards; then work towards the ends and the edges. During installation, make sure the cement boards are resting on the framework.
Installation of Interior Walls
installation of Knauf Wetroom Solutions with AQUAPANEL® technology inside
24
Installation of Interior Walls
installation of Knauf Wetroom Solutions with AQUAPANEL® technology inside
5.2 Insert AQUAPANEL® Cement Board Indoor into the bed of adhesive. Screw panel to the framework. Joint reinforcement of AQUAPANEL® Cement Board Indoor panel is achieved by means of the adhesion technique. There is no need for the time-consuming process of filling and inserting joint tape.
This must be done before the next board is placed.
5.3 AQUAPANEL® Joint Adhesive (PU) must be applied as a continuous bead along the edges of the boards. Before applying the adhesive, ensure that the edges are cleaned using, for example, a wet brush. It takes approximately 50ml/m2 (40ml/m).The tube contains enough adhesive for approximately 6,5 m2.
8. completed wall
The joints between the walls, ceiling and floor require permanent elastic sealing in dry areas. Expansion joints should be at a minimum of 7.5 (7.2) m intervals.
Install the next AQUAPANEL® Cement Board Indoor panel and ensure that the boards are correctly aligned horizontally and vertically. Screw panel to the framework.
6. Place next board
9. Priming
AQUAPANEL® Cement Board Indoor must be primed before tiling or finishing using AQUAPANEL® Board Primer.
Leave the adhesive to harden after which the excess AQUAPANEL® Joint Adhesive (PU) can be scraped off (usually the next day).
7. Scraping off
_ 2524
Surface finishing
For ceramic tile coverings, (tile dimensions ≤ 300 x 300 mm), use a flexible adhesive when placing tiles. The tile adhesive must – as a minimum – meet the requirements of class C2 according to EN 12004.
Note: Where single-layer panels are required in tiling applications, AQUAPANEL® Cement Board Indoor is the best tile backing board!
Boards
Tiling
finishingFor a smooth finish, apply a thin layer of AQUAPANEL® Joint Filler & Skim Coating – white. When dry, the surface can be painted.
Painting
The majority of common painting systems can be used. These include water-based emulsions, matt enamels, polymer resin colours, and epoxy-based enamels.
Alkyd enamels are not compatible with the product.
For confirmation of usage, please refer to the paint manufacturers’ instructions. A test coat is recommended.
For surface finishes up to Q4, apply AQUAPANEL® Q4 Finish over the entire pre-prepared (filled and reinforced) surface.
After drying, do any re-finishing with an electric orbital sander (grade 120 or finer).
AQUAPANEL® Cement Board Indoor can be prepared for painting by coating it fully with AQUAPANEL® Joint Filler & Skim Coating – white (minimum coating depth 4 mm).
Skim coating
Finishing
Apply AQUAPANEL® Reinforcing Mesh and embed it in the skim coat with a trowel.
reinforcing
26
Surface finishing
For fine finishing to a Q4 surface quality, use AQUAPANEL® Q4 Finish ready-to-use skim coat.
Coating above the tiled section up to Q4 quality
full surface skim coating
Apply AQUAPANEL® Q4 Finish to completely cover the untiled areas using a 20 cm wide finishing trowel. Apply the filler solidly to fill in uneven areas in the joints and smooth the surface texture. If necessary, sand down with paper. If a Q4 surface quality is required, apply a further layer of AQUAPANEL® Q4 Finish. After approx. 24 hours drying, sand with abrasive paper (grade 120 or finer). For particularly smooth surfaces, sand down with, for example, an electric orbital sander.
CoatingDepending on the intended use and requirements, water emulsion paints, emulsion silicate paints or latex paints can be used.
Note: The tiled section of the wall should be > 50% of the total height of the wall.
Not suitable for areas subject to water spray!
Using a 15 cm wide stainless steel finishing trowel, apply AQUAPANEL® Q4 Finish to the visible joints which have been bonded with AQUAPANEL® Joint Adhesive (PU). Embed the glass fibre joint cover strips (e.g. GLASS FIBRE JOINT COVER STRIPS) into the centre of the paste so that they overlap the joints. Apply a thin layer of AQUAPANEL® Q4 Finish to the cover strips. Remove excess material.
Note: AQUAPANEL® Cement Board Indoor is already glued using AQUAPANEL® Joint Adhesive (PU).
Embedding glass fibre joint cover strips
Fill all screw heads. If necessary, after drying, use a hand sander to remove irregularities from the screw holes.
Embed fastener heads
Sand away all surface unevenness. Apply AQUAPANEL® Q4 Finish to a width of at least 20 cm (5 cm beyond the edge of the first layer). Embed fastener heads and sand down any uneven areas.
Smoothing over joints and fasteners
_ 2726
Generalfinishing options
Gypsum Boards can be used with every conceivable surface finishing but the quality of the finishing depends on the decorative finish required as part of the contract and the skills of the dryliner.
When closing the joints on the plaster boards, it is possible to achieve four quality levels.
Level of finishing Q1 Q2 (Standard) Q3 Q4
Jointed surface Smooth surface for normal optical
requirements
Smooth surface for higher visual
requirements
Smooth surface for high visual
requirements
Aesthetic requirements None Normal Enhanced. Few marks and traces
under direct light. Shading is still
possible under shallow light angles
High end. Minimised appearance
of any marks or traces. Shading
caused by shallow light angles
will be avoided to a large extent.
Application requirements Joints and screw heads filled with
joint compound
Joints and screw heads filled,
finished to achieve a continuous
transition to the board surface,
sanded if necessary
Joints and screw heads filled,
finished (Q2), plus wide finish
trowelling and a sharp trowelled
full cover of the plaster board surface
(filling the paper pores), sanded if
necessary.
Joints and screw heads filled,
finished (Q2) plus a complete
surface covering skim coat of min
1 mm thickness, sanded if
necessary.
Finished surface suitability Only suitable for functional
applications such as stability, fire
resistance and sound insulation.
E.g. filing joints of the first board
layer which is under tile coverings or
thick layered plasters.
Medium and coarse-structured wall
coverings, matt filling, medium
and coarse-structured paint coatings/
coats, top coats (particle size/
largest particle over 1 mm).
Fine-structured wall coverings, matt,
fine-structured paint coatings/coats,
top coats (largest particle size less
than 1 mm).
Smooth or glossy wall coverings,
e.g. metal-based or vinyl wallpapers,
scumbles, paints or coats up to
medium gloss, stucco marble or
similar specialist decorative finishes.
Flatness requirements Refer to National standards
Note: Priming the surface will depend on the selected interior finishing option. Quality level of surface finishing depends on the skills of the dryliner.
Quality classification according to leaflet no 2 “Skimming of Plaster Boards – Surface Qualities” of the Plasterboard Industry Group Association, which provides for four levels of quality.
Surface finishing and quality levels
28
Dry applicationsinterior finishing
In order to close the joints and to prepare the surface for the finishing options the following materials can be used:
UNifLott: “the original” for Q1– Q2 surface quality tested and approved standard product for manual use
triAS: “the efficient” for Q1– Q2 surface quality joints don‘t show due to carton-grey colour good absorption behaviour extremely low shrinkage when drying tested and approved standard product for manual use
rEAdygiPS: “the quickstarter” ideal for Q1– Q4 quality ready to use from the bucket and processing-friendly full-surface joint compound to be used with Joint Tape Kurt very easy to sand very fine surface after drying for manual and machine use
mULti-fiNiSh / mULti-fiNiSh m: “the noble” ideal for Q4 quality suitable for almost all subsurfaces use for filling of uneven and rough surfaces for manual and machine use
Joint tape KUrt Joint Tape KURT is a 50 mm wide strip of special
paper which is used to reinforce the joint filling and edges of Gypsum Boards and Gypsum Fibre Boards. Particulary resistant to tearing.
PUtzgrUNd PUTzGRUND is a synthetic resin dispersion filled with fine
quartz sand, white pigmented and alkali-resistant. It is used for interior priming on Gypsum Boards before plastering and pre-treatment of absorbent and non-absorbent substrates.
Joint treatment: Gypsum Boards
_ 2928
30
Dry applicationsinterior finishing
TRIAS / UNIFLOTT / UNIFLOTT impregnated
hrAK – semi-circular flattened longitudinal edge hrK – semi-circular longitudinal edge AfK – long side panel edge
cut edge and develled/mixed jointTRIAS / UNIFLOTT / UNIFLOTT impregnated
for surfaces with highest optical requirements
for surfaces with higher optical requirements
for surfaces with conventional optical requirements
TRIAS / UNIFLOTT / UNIFLOTT impregnated + Joint Tape KURTREADyGIPS or PUTzGRUND and MULTI-FINISH / MULTI-FINISH M
TRIAS / UNIFLOTT / UNIFLOTT impregnated + Joint Tape KURT READyGIPS
TRIAS / UNIFLOTT / UNIFLOTT impregnated + Joint Tape KURT
TRIAS / UNIFLOTT / UNIFLOTT impregnated + Joint Tape KURT
the technically required surface – without optical requirements
TRIAS / UNIFLOTT / UNIFLOTT impregnatedREADyGIPS or PUTzGRUND and MULTI-FINISH / MULTI-FINISH M
TRIAS / UNIFLOTT / UNIFLOTT impregnated READyGIPS
TRIAS / UNIFLOTT / UNIFLOTT impregnated
TRIAS / UNIFLOTT / UNIFLOTT impregnated
_ 3130
Installation of Gypsum Boardsinstallation of Knauf Wetroom Solutions
Use the right product for the job depending on whether thermal insulation, acoustic insulation or fire protection is required. Cut insulation to width /length with a sharp long bladed knife.
2. Place insulation material
5. Joint treatment (dry applications only)Fill joints (e.g. standard Gypsum Board application with HRAK edge). Use trowel to fill joints with suitable joint filler (Uniflott). For double layer system, the joints of the first layer of board must also be filled before placing the second layer of boards.
Run the trowel progressively down the joint applying sufficient pressure to squeeze out entrapped air. Allow the joint filler to set for approx. 1 hour. If required, sand lightly to remove any high spots. Remove surface dust.
Apply an additional thinner layer of joint filler and remove any surplus filler. Feather out application beyond the joints – approximately 100 to 200 mm.
Allow the joint filler to set for approx. 1 hour. If required, sand lightly to remove any high spots. Remove surface dust.
Make sure all electrical installation has been completed. To ensure air tightness of building construction, apply vapour barrier to the inside if specified in building physical calculation.
Where the wall construction includes a double layer of Gypsum Board, the vapour barrier can be placed between the two layers for fast easy installation.
The vapour barrier must overlap where more than 1 layer is placed. It must also overlap when applied at connections to other building elements. Use suitable glue and tapes.
Where services penetrate the building elements, ensure that the penetrations are sealed in order to obtain optimum air tightness.
3. Apply vapour barrier (if necessary)
Screw Gypsum Boards tosubstructure using DrywallScrews (TN3.5/35).
4. install gypsum Board (dry applications only) Once joints have been filled and after drying, if finishing is not satisfactory, use trowel to apply a tight coat of Uniflott joint filler. Feather out beyond previous application of material. Allow the joint treatment to set. Lightly sand to remove any minor imperfections and create a smooth surface.
If required, apply a final coat of Finish-pastös and feather out beyond previous application. Lightly sand to remove minor imperfections. Remove surface dust.
Note: Priming the surface will depend on the selected interior finishing option.
See section Interior finishing for more details.
Note on interior finishing (dry applications only)
1. Studs to be installed first
32
Choose the perfect surface finishinginterior finishing options
ceramic tiles Q1
Ä
Å
Ç
Ñ ÉÖ
1. AQUAPANEL® Cement Board Indoor2. AQUAPANEL® Maxi Screw 3. AQUAPANEL® Joint Adhesive (PU)4. AQUAPANEL® Board Primer5. Knauf Tile Adhesive6. Ceramic tiles
decorative plaster finish Q2
1. Knauf Gypsum Board with HRAK edge2. Knauf Drywall Screws3. Knauf UNIFLOTT4. Knauf TIEFENGRUND 5. Knauf EASyPUTz
Ñ
É
Ç
Å
Ä
_ 3332
Wallpaper finish Q3
1. Knauf Gypsum Board with HRAK edge2. Knauf Drywall Screws3. Knauf UNIFLOTT4. Knauf TIEFENGRUND 5. Wallpaper
Paint finish Q4
1. AQUAPANEL® Cement Board Indoor2. AQUAPANEL® Maxi Screw 3. AQUAPANEL® Joint Adhesive (PU)4. AQUAPANEL® Board Primer5. GLASSFIBRE JOINT COVERING STRIP6. AQUAPANEL® Q4 Finish
Ä
Å
Ç
Ñ
É
Q1 Q2 (Standard) Q3 Q4
Level of finishing Jointed surfaceSmooth surface for normal optical
requirements.
Smooth surface for higher visual
requirements.
Smooth surface for high visual
requirements.
Ä
Å
ÇÑ
É
Ö
ÖÖ
34
r: > 3m_
Curved interior wallsinstallation details
Gypsum Board may be used to form almost any cylindrically curved surface. To prevent flat spots on the curved surface, profiles must be spaced more closely together than required for typical flat wall or ceiling surfaces.
Gypsum Board should be bent wet. Evenly spray water on the surface so that the water is allowed to soak into the core before application. The board must be dried within 24 hours of wetting to prevent the development of mould. Fans and mechanical dehumidifiers should be used to accelerate drying when conditions are not conducive to natural drying. When the Gypsum Board dries thoroughly, its original hardness is regained.
AQUAPANEL® cement Board indoor
For applications such as arches AQUAPANEL® Cement Board Indoor can be curved. Using metal shears, cut the UW-profile. Fit the UW-profile to the desired radius. Crimp the CW-profile to the perforated UW-profile. Before installation, bend the cement board panel. The fine cracks that occur on the board surface will not cause any loss of performance.
Board size: 1200/2400/1250/ 2500 x 900 mmMinimum bending radius ≥ 3 mStrip size: 1200/2400/1250/ 2500 x 300 mmMinimum bending radius ≥ 1 m Max. stud spacing: ≤ 300/312.5 mm (external radius)
Gypsum Boards
_ 3534
Board thickness Bending radius r of Gypsum Boards
d mm Dry bending mm Wet bending mm
6.5 ≥ 1000 ≥ 300
9.5 ≥ 2000 ≥ 500
12.5 ≥ 2750 ≥ 1000
Longitudinal bending only
Length of layout L
Angle α = 90° Angle α = 180° All angles up to α = 180°
21
Knauf Metal Stud Partitions W11Bent Partitions with Bent Knauf Boards and UW Runners 75x40x0.6 Pre-punched at Web
4. Lay board on precast molding device, fix with tapeand let it dry.
a few minutes. Repeat process until excessive water drains.3. Wet the board by spraying or with lambskin roller and let it settle for
Perforate the board laterally and longitudinally with Spike Roller.2.
longit
udina
l dire
ction
wet bending
1. Put the cut-to-length Knauf Boards on a grid made of
excessing the grid on the perimeters (so excess water can drip off).
Wet bending
length
of la
yout
Biegeanleitung
Detail scale 1:5
Dry bendingBend Knauf Boards over metal grid or frame.1.Fix with Drywall Screws following the bending continuously.2.
W111-SO1 Bent Partition
UW Runner75x40x0.6
CW Stud75x50x0.6
pre-punched at webUW Runner 75x40x0.6
(Mat. no. 00003387)
Drywall Screw TN
e.g. Knauf Mold Boards2x 6.5 mm
Knauf Uniflott + Joint TapeNailable Plug UW Runner
75x40x0.6
cut outside flange at web punches bend UW Runners to required radiusconnect Knauf CW Studs to pre-punched UW Runners by crimpingcladding lateral
Assembly
spacing Knauf CW Studs:spacing Nailable Plug:
� 312.5 mm� 300 mm
3.
1.2.
4.
channels or similar with the side to be compressed on top and
Knauf
to fix the
molding device
molding device
batten
board
to support boardsangle or CD Channel
Knauf Board stripcut boardd � 12.5 mm
(outside radius)
d
rr
mm
� 500 9.5
mm
� 2000
mm 6.5 � 1000 � 300
12.5 � 2750 � 1000d
angle 90°L =
.r2
all angles up to 180°=L r .
angle 180°
=L r180
..
(Mold Board)
essermocebot
di
disecafe
p
s d
e i d
t o b e c om re s s ef a c e s i
s d
e
p
d e
Inside Arch - Concave Outside Arch - Convex
ddry
Board Bending radius r
bendingwetbending
thickness
longitudinal bending only
Length of layout L
Angle or CD profile to support the board Board strips; cutted Board thickness ≥ 12.5 mm
Bending device
Inside arch – concave, outside arch – convex
Inside arch – concave, outside arch – convex
Wet bending1. Put the cut-to-length Gypsum Boards on a grid made of channels
or similar with the side to be compressed on top and excessing the grid on the perimeters (so excess water can drip off).
2. Perforate the board laterally and longitudinally with spike roller.3. Wet the board by spraying or with lambskin roller and let it settle
for a few minutes. Repeat process until excessive water drains.4. Lay board on precast moulding device, fix with tape and
let it dry.
dry bending1. Bend Gypsum Boards over metal grid or frame.2. Fix with Drywall Screws following the bending continuously.
21
Knauf Metal Stud Partitions W11Bent Partitions with Bent Knauf Boards and UW Runners 75x40x0.6 Pre-punched at Web
4. Lay board on precast molding device, fix with tapeand let it dry.
a few minutes. Repeat process until excessive water drains.3. Wet the board by spraying or with lambskin roller and let it settle for
Perforate the board laterally and longitudinally with Spike Roller.2.
longit
udina
l dire
ction
wet bending
1. Put the cut-to-length Knauf Boards on a grid made of
excessing the grid on the perimeters (so excess water can drip off).
Wet bending
length
of la
yout
Biegeanleitung
Detail scale 1:5
Dry bendingBend Knauf Boards over metal grid or frame.1.Fix with Drywall Screws following the bending continuously.2.
W111-SO1 Bent Partition
UW Runner75x40x0.6
CW Stud75x50x0.6
pre-punched at webUW Runner 75x40x0.6
(Mat. no. 00003387)
Drywall Screw TN
e.g. Knauf Mold Boards2x 6.5 mm
Knauf Uniflott + Joint TapeNailable Plug UW Runner
75x40x0.6
cut outside flange at web punches bend UW Runners to required radiusconnect Knauf CW Studs to pre-punched UW Runners by crimpingcladding lateral
Assembly
spacing Knauf CW Studs:spacing Nailable Plug:
� 312.5 mm� 300 mm
3.
1.2.
4.
channels or similar with the side to be compressed on top and
Knauf
to fix the
molding device
molding device
batten
board
to support boardsangle or CD Channel
Knauf Board stripcut boardd � 12.5 mm
(outside radius)
d
rr
mm
� 500 9.5
mm
� 2000
mm 6.5 � 1000 � 300
12.5 � 2750 � 1000d
angle 90°L =
.r2
all angles up to 180°=L r .
angle 180°
=L r180
..
(Mold Board)
essermocebot
di
disecafe
p
s d
e i d
t o b e c om re s s e
f a c e s i
s d
e
p
d e
Inside Arch - Concave Outside Arch - Convex
ddry
Board Bending radius r
bendingwetbending
thickness
longitudinal bending only
Length of layout L
Knauf UW profile
Knauf sinus flexible U-connection profile
Knauf Drywall Screw
e.g. Knauf Gypsum Board
Knauf UW profile
Inside arch – concave, outside arch – convex
Knauf UNIFLOTT + Knauf Joint Tape KURT
Assembly1. Cut outside flange at web punches.2. Bend UW profiles to required radius.3. Connect CW profiles to pre-punched UW profiles by crimping.4. Cladding lateral.Spacing CW profiles: ≤ 312.5 mm (outside radius)Spacing anchor: ≤ 300 mm
Curved interior wall construction
batten to fix the board
leng
th o
f lay
out
long
itudi
nal d
irect
ion
36
installation of ceilings
AQUAPANEL 1 Cement Board Indoor14
Montage von DeckenVariante 1
Bei der Unterkonstruktion werden mindestens folgende Abstände vorausgesetzt: Abhänger a = 750 mmTragprofil CD 60/27/06 b = 450 mmGrundprofil CD 60/27/06 c = 1000 mm
Die erste Platte wird entlang der Traglattung (quer zur Grund-lattung) sorgfältig ausgerichtet. Mit den AQUAPANEL® Maxi Schrauben werden die AQUAPANEL® Cement Board Indoor in einem Abstand von a = 170 mm (22 Stück/m2) an die Unterkonstruktion geschraubt.
Die folgenden Platten werden mit ca. 3 – 4 mm Fuge im Ver-bund montiert, Kreuzfugen sind nicht zulässig. Die Fugen werden mit dem AQUAPANEL® Fugen-spachtel - grau geschlossen und das AQUAPANEL® Fugenband in die Spachtelmasse einge arbeitet. Die Schraubenköpfe werden ebenfalls verspachtelt.
Nach Erhärtung wird die Fläche mit AQUAPANEL® Grundierung – innen grundiert (Grundierung /Wasser 1:2).
AQUAPANEL® Q4 – Finish kann nun nach Trocknung der Grundierung vollflächig und ohne Gewebearmierung aufgetragen werden. Der Auftrag in einem Arbeitsgang beträgt max. 2 mm. Nach der Trocknung ist die Ober-fläche zu schleifen (Schleifpapier 120 oder feiner). Ggf. ist ein zwei-ter Spachtelvorgang erforderlich. Mit AQUAPANEL® Q4 – Finish kann eine Oberflächenqualität bis Q4 erreicht werden. Bitte beachten Sie die besonderen Hinweise auf Seite 15.
Alternativ:Über die beschriebene Arbeits-weise hinaus ist ein Verkleben der Plattenkanten in der Decken-anwendung möglich. Die Unter-konstruktion und Plattenrichtung ist wie in Variante 1 auszuführen. Die Montage ist wie im Wand-bereich vorzunehmen. Dehnfugen sind alle 7,5 m anzuordnen.
Montage Innenwände s. S. 9 ff.
The following minimum spacings are required for the framework: Hanger a = 750 mm Support section CD 60/27/06 b = 450 mm Base section CD 60/27/06 c = 1000 mm
Align the first cement board panel carefully along the lath, perpendicular to the batten. Using AQUAPANEL® Maxi screws, screw the AQUAPANEL® Cement Board Indoor panel to the framework, with spacing of a = 170 mm (22 pieces/m2). As an alternative to the method
described here, the edges of the board panel can be glued into the ceiling application. The framework and boards should be arranged and positioned as shown in Variant 1. To assemble, proceed as for a wall installation. Expansion joints should be installed at 7.5 m intervals.
Alternative
Leave a gap of at least 3-4 mm between joints and make sure all joints are staggered. After installation, joints should be filled in with AQUAPANEL® Joint Filler – grey with AQUAPANEL® Tape embedded into the filler. Also fill all screw heads.
AQUAPANEL 1 Cement Board Indoor14
Montage von DeckenVariante 1
Bei der Unterkonstruktion werden mindestens folgende Abstände vorausgesetzt: Abhänger a = 750 mmTragprofil CD 60/27/06 b = 450 mmGrundprofil CD 60/27/06 c = 1000 mm
Die erste Platte wird entlang der Traglattung (quer zur Grund-lattung) sorgfältig ausgerichtet. Mit den AQUAPANEL® Maxi Schrauben werden die AQUAPANEL® Cement Board Indoor in einem Abstand von a = 170 mm (22 Stück/m2) an die Unterkonstruktion geschraubt.
Die folgenden Platten werden mit ca. 3 – 4 mm Fuge im Ver-bund montiert, Kreuzfugen sind nicht zulässig. Die Fugen werden mit dem AQUAPANEL® Fugen-spachtel - grau geschlossen und das AQUAPANEL® Fugenband in die Spachtelmasse einge arbeitet. Die Schraubenköpfe werden ebenfalls verspachtelt.
Nach Erhärtung wird die Fläche mit AQUAPANEL® Grundierung – innen grundiert (Grundierung /Wasser 1:2).
AQUAPANEL® Q4 – Finish kann nun nach Trocknung der Grundierung vollflächig und ohne Gewebearmierung aufgetragen werden. Der Auftrag in einem Arbeitsgang beträgt max. 2 mm. Nach der Trocknung ist die Ober-fläche zu schleifen (Schleifpapier 120 oder feiner). Ggf. ist ein zwei-ter Spachtelvorgang erforderlich. Mit AQUAPANEL® Q4 – Finish kann eine Oberflächenqualität bis Q4 erreicht werden. Bitte beachten Sie die besonderen Hinweise auf Seite 15.
Alternativ:Über die beschriebene Arbeits-weise hinaus ist ein Verkleben der Plattenkanten in der Decken-anwendung möglich. Die Unter-konstruktion und Plattenrichtung ist wie in Variante 1 auszuführen. Die Montage ist wie im Wand-bereich vorzunehmen. Dehnfugen sind alle 7,5 m anzuordnen.
Montage Innenwände s. S. 9 ff.
AQUAPANEL 1 Cement Board Indoor14
Montage von DeckenVariante 1
Bei der Unterkonstruktion werden mindestens folgende Abstände vorausgesetzt: Abhänger a = 750 mmTragprofil CD 60/27/06 b = 450 mmGrundprofil CD 60/27/06 c = 1000 mm
Die erste Platte wird entlang der Traglattung (quer zur Grund-lattung) sorgfältig ausgerichtet. Mit den AQUAPANEL® Maxi Schrauben werden die AQUAPANEL® Cement Board Indoor in einem Abstand von a = 170 mm (22 Stück/m2) an die Unterkonstruktion geschraubt.
Die folgenden Platten werden mit ca. 3 – 4 mm Fuge im Ver-bund montiert, Kreuzfugen sind nicht zulässig. Die Fugen werden mit dem AQUAPANEL® Fugen-spachtel - grau geschlossen und das AQUAPANEL® Fugenband in die Spachtelmasse einge arbeitet. Die Schraubenköpfe werden ebenfalls verspachtelt.
Nach Erhärtung wird die Fläche mit AQUAPANEL® Grundierung – innen grundiert (Grundierung /Wasser 1:2).
AQUAPANEL® Q4 – Finish kann nun nach Trocknung der Grundierung vollflächig und ohne Gewebearmierung aufgetragen werden. Der Auftrag in einem Arbeitsgang beträgt max. 2 mm. Nach der Trocknung ist die Ober-fläche zu schleifen (Schleifpapier 120 oder feiner). Ggf. ist ein zwei-ter Spachtelvorgang erforderlich. Mit AQUAPANEL® Q4 – Finish kann eine Oberflächenqualität bis Q4 erreicht werden. Bitte beachten Sie die besonderen Hinweise auf Seite 15.
Alternativ:Über die beschriebene Arbeits-weise hinaus ist ein Verkleben der Plattenkanten in der Decken-anwendung möglich. Die Unter-konstruktion und Plattenrichtung ist wie in Variante 1 auszuführen. Die Montage ist wie im Wand-bereich vorzunehmen. Dehnfugen sind alle 7,5 m anzuordnen.
Montage Innenwände s. S. 9 ff.
AQUAPANEL 1 Cement Board Indoor14
Montage von DeckenVariante 1
Bei der Unterkonstruktion werden mindestens folgende Abstände vorausgesetzt: Abhänger a = 750 mmTragprofil CD 60/27/06 b = 450 mmGrundprofil CD 60/27/06 c = 1000 mm
Die erste Platte wird entlang der Traglattung (quer zur Grund-lattung) sorgfältig ausgerichtet. Mit den AQUAPANEL® Maxi Schrauben werden die AQUAPANEL® Cement Board Indoor in einem Abstand von a = 170 mm (22 Stück/m2) an die Unterkonstruktion geschraubt.
Die folgenden Platten werden mit ca. 3 – 4 mm Fuge im Ver-bund montiert, Kreuzfugen sind nicht zulässig. Die Fugen werden mit dem AQUAPANEL® Fugen-spachtel - grau geschlossen und das AQUAPANEL® Fugenband in die Spachtelmasse einge arbeitet. Die Schraubenköpfe werden ebenfalls verspachtelt.
Nach Erhärtung wird die Fläche mit AQUAPANEL® Grundierung – innen grundiert (Grundierung /Wasser 1:2).
AQUAPANEL® Q4 – Finish kann nun nach Trocknung der Grundierung vollflächig und ohne Gewebearmierung aufgetragen werden. Der Auftrag in einem Arbeitsgang beträgt max. 2 mm. Nach der Trocknung ist die Ober-fläche zu schleifen (Schleifpapier 120 oder feiner). Ggf. ist ein zwei-ter Spachtelvorgang erforderlich. Mit AQUAPANEL® Q4 – Finish kann eine Oberflächenqualität bis Q4 erreicht werden. Bitte beachten Sie die besonderen Hinweise auf Seite 15.
Alternativ:Über die beschriebene Arbeits-weise hinaus ist ein Verkleben der Plattenkanten in der Decken-anwendung möglich. Die Unter-konstruktion und Plattenrichtung ist wie in Variante 1 auszuführen. Die Montage ist wie im Wand-bereich vorzunehmen. Dehnfugen sind alle 7,5 m anzuordnen.
Montage Innenwände s. S. 9 ff.
Variant 1
AQUAPANEL 1 Cement Board Indoor14
Montage von DeckenVariante 1
Bei der Unterkonstruktion werden mindestens folgende Abstände vorausgesetzt: Abhänger a = 750 mmTragprofil CD 60/27/06 b = 450 mmGrundprofil CD 60/27/06 c = 1000 mm
Die erste Platte wird entlang der Traglattung (quer zur Grund-lattung) sorgfältig ausgerichtet. Mit den AQUAPANEL® Maxi Schrauben werden die AQUAPANEL® Cement Board Indoor in einem Abstand von a = 170 mm (22 Stück/m2) an die Unterkonstruktion geschraubt.
Die folgenden Platten werden mit ca. 3 – 4 mm Fuge im Ver-bund montiert, Kreuzfugen sind nicht zulässig. Die Fugen werden mit dem AQUAPANEL® Fugen-spachtel - grau geschlossen und das AQUAPANEL® Fugenband in die Spachtelmasse einge arbeitet. Die Schraubenköpfe werden ebenfalls verspachtelt.
Nach Erhärtung wird die Fläche mit AQUAPANEL® Grundierung – innen grundiert (Grundierung /Wasser 1:2).
AQUAPANEL® Q4 – Finish kann nun nach Trocknung der Grundierung vollflächig und ohne Gewebearmierung aufgetragen werden. Der Auftrag in einem Arbeitsgang beträgt max. 2 mm. Nach der Trocknung ist die Ober-fläche zu schleifen (Schleifpapier 120 oder feiner). Ggf. ist ein zwei-ter Spachtelvorgang erforderlich. Mit AQUAPANEL® Q4 – Finish kann eine Oberflächenqualität bis Q4 erreicht werden. Bitte beachten Sie die besonderen Hinweise auf Seite 15.
Alternativ:Über die beschriebene Arbeits-weise hinaus ist ein Verkleben der Plattenkanten in der Decken-anwendung möglich. Die Unter-konstruktion und Plattenrichtung ist wie in Variante 1 auszuführen. Die Montage ist wie im Wand-bereich vorzunehmen. Dehnfugen sind alle 7,5 m anzuordnen.
Montage Innenwände s. S. 9 ff.
Once the primer has dried, AQUAPANEL® Q4 Finish can be applied to the entire surface without any reinforcing. No more than 2mm of coating is applied in a single step. Once the finish has dried, sand the surface (using 120-grit sandpaper or finer). A second coat of finish may be required. AQUAPANEL® Q4 Finish achieves a finish of up to Q4 surface quality. Please see the specific instructions on page 15.
After hardening, prime the surface over using AQUAPANEL® Board Primer (primer/water 1.2)
_ 3736
Align the first AQUAPANEL® Cement Board Indoor panel carefully, perpendicular to the supporting profile. Screw the panel to the framework using AQUAPANEL® Maxi Screws (material requirement 25 pcs/m2). The centre space between the supporting profiles is 300/312.5 mm.
Leave a gap between joints of at least 3-4 mm. Make sure all joints are staggered. After installation, joints should be filled in with AQUAPANEL® Joint Filler – grey with the 10 cm wide AQUAPANEL® Tape embedded into the filler. Fill all screw heads.
In rooms with continuous high humidity levels such as commercial kitchens, swimming pools, saunas or chemical laboratories, it is necessary to provide improved corrosion protection for the metal framework.
When cutting AQUAPANEL® Cement Board Indoor, the distance of the screws from the board edge must be ≥ 15 mm. The distance between screws must be ≤ 250 mm.
Fasten the hanger of the framework with suitable, building authority approved ceiling pins e.g. Type KDM Kunkel ceiling pin or MKT anchor bolt B6 material 1.4529.
We recommend that expansion joints are included at maximum 15 m intervals. Align with the expansion joints in the background if practical.
Special notes
Prime the surface over using AQUAPANEL® Board Primer (primer/water 1.2).
Use AQUAPANEL® Joint Filler & Skim Coating – white to coat the panels to at least 4 mm depth all-over, and embed the AQUAPANEL® Reinforcing Mesh.
For fine finishing up to Q4 surface quality, use AQUAPANEL® Q4 Finish on AQUAPANEL® Joint Filler & Skim Coating – white.
Variant 2
38
Permitted console loads
Light partition walls built with AQUAPANEL® Cement Board Indoor can accept console loads of different sizes. Should loads be inserted in double-layer walls, the stud rows must be connected together using consoles to ensure tensile strength. The size and geometry of the load must be monitored for all walls. A deciding size is the “load height“, i.e. the distance of the load outer edge from the wall or the height of a hanging shelf or hanging cabinet. The following cases can be distinguished depending on the size and height of the load:
Light console loads up to 40 kg/metre wall length Light console loads can be arranged on any position of the wall or facing panel. If the load is attached to the panel, the distance of the fastening points from each other must be at least 75 mm. Loads of up to 40 kg per metre wall length at a load height of 60 cm are considered light console loads. Loads can be increased if the load height is low.
Maximum size “light console loads” as a function of load depth b
Load depth (cm) 10 20 30 40 50 60
Permissible console load P
(kg/metre wall length)78 71 63 55 48 40
Other console loads of 40 to 70 kg/metre wall length Other console loads can be attached in any position on a single or double stud installation with double-layer panelling of AQUAPANEL® Cement Board Indoor. With double stud walls, the stud rows must be fixed with consoles to ensure tensile strength. Loads of between 40 and 70 kg per metre wall length at a load height of 60 cm are considered medium console loads. Loads can be increased if the load height is low.
Maximum size “other console loads” as a function of load depth b
Load depth (cm) 10 20 30 40 50 60
Permissible console load P
(kg/metre wall length)107 100 93 85 78 70
Heavy console loads of 70 to 150 kg/metre wall length Heavy console loads must be attached to special construction parts such as cross beams, console frames or cross member bracing. Cross beams and cross member bracings are directly linked to the framework so that the loads can be securely taken into the framework. Supporting frames are fastened to the framework depending on the type of construction but are generally anchored directly to the original floor.
Light console loads
Other console loads
Permitted console loads
_ 3938
Wall hooks
construction details
Plastic cavity wall plugs Metal cavity wall plugs5 kg 10 kg 15 kg
Hooks for light, flat objects up to 15 kg/m Light and other bracket loads up to 70kg/m
Flat loadsLoads up to 15 kg can be secured using simple hooks. Flat loads up to 50 kg are fastened using metal or plastic cavity wall plugs.
Light and other bracket loadsLight and other bracket loads are secured using at least two plastic or metal cavity wall plugs. Plugs should be spaced more than 75 mm apart. See table.
Plug load-bearing capacity (kg) under pull and shear
Panel thickness (mm)Plastic cavity wall plugs Ø 8 Ø 10 mm
Metal cavity wall plug M5 or M6 screw
KnaufHartmut
1 x 12.5 30 kg 40 kg 30 kg 60 kg
2 x 12.5 40 kg 70 kg 50 kg 110 kg
Ceiling hooks
Tilting ceiling hooks Spring toggle ceiling hooks
Light loads, which do not exceed the load-bearing capacity of a light suspended ceiling, may be fastened to the panel. Heavier loads must be secured separately to the original ceiling. Tilting ceiling hooks or spring toggle ceiling hooks should be used to fix these.
The maximum possible load capacity depends on the individual ceiling construction. The maximum load-bearing capacity of the ceiling hooks is 20 kg in single-layer panelling and 25 kg in double-layer panelling.
Wall hooks
Securing loads to suspended ceilings
40
AQUAPANEL® special fittings
AQUAPANEL® Traverse
I. Attach using crimping pliers II. Stud profile
To ensure light console loads are borne securely, AQUAPANEL® Traverses are attached between the C-wall profiles. The cross panels should be secured twice on each side using crimping pliers. Alternatively, the cross panels can be secured with self-tapping screws.
For single layer panelling, the following maximum loads apply:M type: up to 0.7kN/mMH type: up to 1.5kN/m
For single layer panelling with tiled AQUAPANEL® Cement BoardIndoor or double layer panelling, the following maximum loads apply:M type and MH type: up to 1.5kN/m
AQUAPANEL® traverse
Standard sanitary mounts are used to bear greater loads. Various types of mount are available for the various sanitary objects. Sanitary mounts are secured using either side U-bracing profiles or are anchored directly into the original flooring. Manufacturer guidelines should be followed when assembling.
Sanitary mounts
M type traverse MH type traverse AQUAPANEL® Traverse: installation
AQUAPANEL® Traverse: arrangement and loading
AQUAPANEL® Traverse
Axis frame dimensions 600/625 mm
Height approx. 290 mm
Thickness of metal 0.75 mm with special anti-corrosion layer
M type Without impregnated wood packing
MH typeWith core-impregnated MDF filler,
approx. 18 mm thick
_ 4140
Access Doors comprising aluminium frame with AQUAPANEL® Cement Board Indoor infill which can be used in interior partition walls and suspended ceilings. For use in splash water areas as well as in humid rooms. Both access doors are available in a range of sizes and are fitted with corrosion-resistant profiles and hinges, multiple purpose for wall and ceiling. Doors come with AQUAPANEL® Maxi Screw SB 39 and are available with key locking system on request.
ApplicationAQUAPANEL® Access Doors can be installed in partition and solid walls and ceilings built with AQUAPANEL® Cement Board Indoor. They are easy to install and safe to handle. Walls lined with AQUAPANEL® Cement Board Indoor and with AQUAPANEL® Access Doors are verified waterproof (test report BB 0215069, LGA Bavaria). AQUAPANEL® Access Doors create a dust-proof and airtight closure (classification according to DIN EN 1026 and DIN EN 12207; Class 4) and are smoke-proof according to DIN 18095.
typesAQUAPANEL® Access Doors are available in two different type: AQUAPANEL® Access Door Splash Water Protection: This
universal splashproof type provides a dust-proof and airtight closure, can be installed in wall and ceiling applications and is also suitable for single and double layer panel structures as well as for tiling and plastering. This type has a 4 mm coated edge
AQUAPANEL® Access Door Humid Rooms: This second type for use in areas where splash-water resistant properties are not required. It can be supplied with a coated edge to order which allows the easy application of AQUAPANEL® Q4 Finish and is suitable for use in walls and ceilings. Versions are available for single and double layer walls
construction The frame is made of anodised aluminium with an internal cover
which can be swung out and completely removed Corrosion-resistant profiles and hinges for damp rooms AQUAPANEL® Cement Board Indoor can be glued flush into
position (single and double layer type) Splash-proof AQUAPANEL® Access Doors are fitted with a zero
maintenance seal
AQUAPANEL® Access Doors can be easily installed into partition and installation walls with AQUAPANEL® Cement Board Indoor and are available in different type.
handling & installationAQUAPANEL® Access Door Splash Water ProtectionThe size and position of the access door opening depends on the substructure. The wall opening dimension depends on the size and width of the frame of the AQUAPANEL® Access Door. The opening must be 20 mm bigger than the frame of the AQUAPANEL® Access Door Splash Water Protection.
Fix in place avoiding any distortion. Align the closing system towards the ceiling. Screw the outer frame to the wall substructure and adjust and secure the inside cover safety hinges. Then place the inner cover in position, check that it functions properly, and finish the wall panelling.
AQUAPANEL® Access Door Humid RoomsThe size and position of the access door opening depends on the substructure. The wall opening dimension depends on the size and width of the frame of AQUAPANEL® Access Door. The opening must be 12 mm bigger than the frame of the AQUAPANEL® Access Door Humid Rooms.
Fix in place avoiding any distortion. Align the closing system towards the ceiling. Screw the outer frame to the wall substructure and adjust and secure the inside cover safety hinges. Then place the inner cover in position, check that it functions properly, and finish the wall panelling.
installation timeApprox. 30 – 45 minutes (depending on the size and accessibility of the opening in the substructure)
AQUAPANEL® Access Door
42
method of deliveryPanelling with AQUAPANEL® Cement Board IndoorPanel thickness 12.5 mm2 x 12.5 = 25 mmStandard dimensions WxH*200 x 200 mm (for humid areas)300 x 300 mm400 x 400 mm500 x 500 mm600 x 600 mm
AQUAPANEL® Access Door Splash Water ProtectionItem code:300 x 300 mm*: 140026
AQUAPANEL® Access Door Humid RoomsItem code:300 x 300 mm*: 140027* Other sizes on request.
Note: Both access door types are available in a range of sizes and are fitted with corrosion-resistant profiles and hinges, multiple purpose for wall and ceiling. Doors come with AQUAPANEL® Maxi Screw SB 39 and are available with key locking system on request.
Material Consumption (walls and ceilings)
Material requirement Unit Per m2
AQUAPANEL® Cement Board Indoor m2 1AQUAPANEL® Maxi Screws (SN, SB) pieces 20, stud spacing 400 mmAQUAPANEL® Maxi Screws (SN, SB) pieces 25, stud spacing 300 mmAQUAPANEL® Maxi Screws (SN, SB) pieces 15, stud spacing 600/625 mmAQUAPANEL® Joint Adhesive (PU) ml 50AQUAPANEL® Board Primer g 40 -60AQUAPANEL® Joint Filler & Skim Coating – white kg; layer thickness 1 mm 0.7 (3.5 dry layer thickness 5 mm)AQUAPANEL® Reinforcing Mesh m2 1.1AQUAPANEL® Q4 Finish kg; layer thickness 1 mm 1.7 (3.4 dry layer thickness 2 mm)GLASS FIBRE JOINT COVERING STRIP m 2.1Gypsum Board (single layer) m2 1Drywall Screw pieces 20UNIFLOTT kg 0.5TRIAS kg 0.5FUGENFÜLLER LEICHT kg 0.5READyGIPS kg; joint filling, surface quality level Q2 (4AK boards) depends on joint ratio
kg; full surface scrape filling, surface quality level Q3 based on Q2 0.7kg; full area skim coating e.g. surface quality level Q4 1.5
JOINTFILLER SUPER kg 0.6MULTI-FINISH /MULTI-FINISH M kg; layer thickness 1 mm 1.0EASyPUTz (1 mm grain size)
(0.5 mm grain size)
g 950g 500 – 650
Joint Tape KURT m 2.1TIEFENGRUND ml 70 – 100SPEzIALGRUND g 100 – 200PUTzGRUND kg 0.25
Schematic drawing: water spray protected access panel
Schematic drawing: wet room access panel
_ 4342
Use to cut insulation to appropriate size
Knife
hand held circular saw
For sharp-edged cuts, use a hand-held circular saw with a dust extractor fitted with a carbide or diamond-tipped blade.
Use to cut metal profiles
Scissors/shears
Pendulum jigsawFor sharp-edged cuts and to make cut-outs for wiring and pipes, use a pendulum jigsaw fitted with a carbide or diamond-tipped blade. The diameter of the hole for a pipe should be approximately 10 mm larger than that of the pipe.
Use to cut cement boards and Gypsum Boards: mark the required size on the board with a ruler and pencil. Score one side with a knife, cutting through the mesh or paper. Snap the board along the score. Then cut the mesh/paper on the opposing side.
Knife
Screw gun
To fasten the boards with screws use a screw gun with depth control. This ensures that all screws are countersunk in the same correct way.
Use to mix interior plasters, skimcoats and exterior renders. A tool with 600 rpm is recommended.
Agitator
Use to mix interior plasters, skimcoats and exterior renders.
Knauf Pft g4/g5
for building interior walls with Knauf Wetroom Solutionstool recommendations
44
for building interior walls with Knauf Wetroom Solutionstool recommendations
folding ruler Pencil chalk line tool Spirit level
Use different kinds of trowels to apply joint fillers, skim coats, basecoat, renders etc
trowels
Miscellaneous tools
_ 4544
reference of additional documentation
information on interior systems with Knauf gypsum BoardW11 Knauf Metal Stud PartitionsBrandschutz mit Knauf Knauf Wände – Schallschutz mit System – Anforderungen, Empfehlungen, Berechnungsverfahren information on special interior Knauf panelsK716 Knauf DiamantW15 Knauf DiamantD179 Knauf SoundboardK451 / K751 Fireboard K717 Knauf Silentboard K811 Knauf Vidiwall W35 / W61 / W62 Massivbauplatte
information on Knauf gypsum joint compoundsK432 Knauf Trennfix K434 Knauf Dichtungsband K442a Knauf Fugendeckstreifen Kurt K451 Knauf TIEFENGRUNDK459 Knauf SPEzIALGRUNDK462 Knauf Finish PastösK462 Knauf FUGENFüLLER LEICHT K463 Knauf JOINTFILLER SUPERK464 Knauf READyGIPSK467 Knauf UNIFLOTT zeige mir deine Fugen und ich sag dir, wer du bist Trockenausbau – einfach, schnell und sicher Knauf Readygips – Hochwertige Oberflächen mit Spaßfaktor Perfektion hat Hintergründe – Grundierungen von Knauf information on Knauf insulationLuftdichtheit schützt die Bausubstanz
46
Notes
_ 4746
Knauf Wetroom Solutions with AQUAPANEL® Technology Inside
is a technologically advanced building system. Because it’s a
system, it involves clear step-by-step process from design idea
to project completion. AQUAPANEL® cement board panels,
accessories and services work in unison – you can be certain
that your project will all come together as planned.
www.AQUAPANEL.com
Knauf Aquapanel GmbH & Co. KGzur Helle 1158638 IserlohnGermany
© 2012 EN-06/12
I D E A | D E S I G N | P L A N | R E A L I S A T I O N | C O M P L E T I O N
All technical changes reserved. Only the current printed instructions are valid.
Our warranty is expressly limited to our products in flawless condition. The
constructional and structural properties and characteristic building physics of Knauf
systems can solely be ensured with the exclusive use of Knauf system components,
or other products expressly recommended by Knauf. All application quantities
and delivery amounts are based on empirical data that are not easily transferable
to other deviating areas. All rights reserved. All amendments, reprints and
photocopies, including those of excerpts, require the express permission of
Knauf Aquapanel GmbH & Co. KG, zur Helle 11, 58638 Iserlohn, Germany.
AQUAPANEL® is a registered trademark.