buildings and facilities
TRANSCRIPT
-
8/2/2019 Buildings and Facilities
1/31
Click to edit Master subtitle style
3/30/12
Quality assuranceof buildings and
facilities.Chakravarthy70211886001
M.Phramacy 1st yeartics)
Gokaraju rangaraju
harmacy
-
8/2/2019 Buildings and Facilities
2/31
3/30/12
Contents :Site selectionoverall design conceptplant layoutDesign and construction featuresConstruction materials
lightingair handling systemsplumbing
sewage and refusewashing and toilet facilitiessanitationmaintenance
-
8/2/2019 Buildings and Facilities
3/31
Click to edit Master subtitle style
3/30/12
Site selection:
The requirements of site selection involve thedesign and layout of the facility which mustminimize the possibility of mix ups orcontamination.
Many governments eager to encourageindustry, offer sites with no local governmenttaxes for first five years and also helps infinancial needs.
Certain regional governments havedeveloped scientific parks.
-
8/2/2019 Buildings and Facilities
4/31
Click to edit Master subtitle style
3/30/12
It is vital to ensure that localpopulation is behind the siting of thenew industry.Energy and construction costs can
vary, depending on the location ofthe site. Some areas have access tolow cost electricity, natural gas orlocal solid fuels, oil and coal.
Companies tend to locate in areaswhere there is no. of similarindustries.
-
8/2/2019 Buildings and Facilities
5/31
Click to edit Master subtitle style
3/30/12
Overall design concept:
The execution plan and project stages givenhere for the development of conceptualdesign.Execution plan project stages:
it is done in 4 stages1.Client brief evaluation and assessment2.Process development
3.Conceptual design based on the clientbrief outcome of any previous studies, andfinalized layout4.costing
-
8/2/2019 Buildings and Facilities
6/31
Click to edit Master subtitle style
3/30/12
These four stages can be divide up, allowing a total period of 13weeksStage1-client brief evaluation, weeks 1 and 2:
a complete evaluation of clients brief to establish the basis ofconceptual design.it will include discussions between the client and the contractors
or consultants key team members.
-
8/2/2019 Buildings and Facilities
7/31
Click to edit Master subtitle style
3/30/12
Stage 2 process development, week 3to 6
Having fully assessed the clientsideas and requirements theprocess engineer and, if
necessary, a specialist consultantwill develop process design.During week 6 the proposedprocess and sketched layout are
reviewed in depth with client.
-
8/2/2019 Buildings and Facilities
8/31
Click to edit Master subtitle style
3/30/12
Stage 3 conceptual design, weeks 7 to 10
At the commencement of week 7 thefull team commences full development
of the conceptual design.By the end of the week 10 the conceptis fully defined in drawings,specifications, and written documents.
-
8/2/2019 Buildings and Facilities
9/31
Click to edit Master subtitle style
3/30/12
Stage 4 cost estimation and document
preparation weeks 11to 13:
The final three weeks of the studycomprises :
preparation of cost estimate.finalization of conceptual
design documentation.
-
8/2/2019 Buildings and Facilities
10/31
Click to edit Master subtitle style
3/30/12
Plant layout:
Plant layout refers to the arrangement ofphysical facilities such as machinery,equipment, furniture's etc. with in thefactory building such a manner as to havequickest flow of the material at the lowestcost and with the least amount of handling,in processing the product from the receipt
of material to the shipment of the finishedproduct.Importance:Optimum relationship among output, floor
area and manufacturing process.Provides flexibilit of o erations
-
8/2/2019 Buildings and Facilities
11/31
Click to edit Master subtitle style
3/30/12
Proper and efficient utilization of available floorspace.Provide enough production capacity.Reduce material handlings cost.
Utilize labour efficientlyReduce accidents.Provide ease of supervision and controlAllow ease of maintenance
Allow high machine or equipment utilizationImprove productivity.
-
8/2/2019 Buildings and Facilities
12/31
Click to edit Master subtitle style
3/30/12
Design and construction
featuresMainly two areas of concern externalenvironment and internal environment
Pertinent consideration prior to purchase:a) Adequate space.b) Availability of water.c) Accessibility for employees, materials and
visitors.d) Environment.e) Security.
-
8/2/2019 Buildings and Facilities
13/31
Click to edit Master subtitle style
3/30/12
After identified a suitable location ,sitedevelopment plan is prepared and willinclude:
a) laws and regulationsb) Storm water and waste managementc) Site security and access fences, guards
posts, camerasd) Buildings sitting, layout, usage.e) utilities-design, layoutf) Equipment design, layout, sparesg) Traffic flowh) Safety.
-
8/2/2019 Buildings and Facilities
14/31
Click to edit Master subtitle style
3/30/12
Construction materials
(i)Walls :Position of walls should provide an orderly
movement.
Interrelationship of different operationsshould minimize the cross contamination.
Plaster finish on concrete blocks or gypsumboard.
Finish should be smooth, usually with epoxypaint
-
8/2/2019 Buildings and Facilities
15/31
Click to edit Master subtitle style
3/30/12
(ii)Floors :Floor covering should be selected for
durability and cleanability.
Terrazzo provides a hard wearingfinish, both tiles and poured-in-place
finishes are available
Terrazzo tile
-
8/2/2019 Buildings and Facilities
16/31
Click to edit Master subtitle style
3/30/12
Epoxy terrazzo is mainly used, epoxysubstrate which contains either marble orglass chips is first toweled evenly ontothe concrete and then ground andpolished in a number of successive steps.Ceramic and vinyl tiles usually are notrecommended for production areas.Welded vinyl sheets are used inproduction area of injectables
-
8/2/2019 Buildings and Facilities
17/31
Click to edit Master subtitle style
3/30/12
(iii)Ceilings :Suspended ceilings may be provided inoffice areas, laboratories, toilets and
cafeterias.They usually consist of lay in acoustical
panels.
-
8/2/2019 Buildings and Facilities
18/31
Click to edit Master subtitle style
3/30/12
(iv)Service:
Provisions must be made for drains,water, electricity, and other services toallow for ease of maintenance.
-
8/2/2019 Buildings and Facilities
19/31
Click to edit Master subtitle style
3/30/12
Lighting:
Adequate light shall be provided in all areas.Normally a range of 70-100 lux ensures worker comfort and ability toperform efficiently and effectively.200 lux is needed for special areas, such as inspection of filled vials.
-
8/2/2019 Buildings and Facilities
20/31
Click to edit Master subtitle style
3/30/12
Air handling system:
Equipment for adequate control over airpressure ,micro-organisms, dust, humidityand temperature should be provided
Air filtration include pre filters andparticulate filters.Air handling systems for manufacture,processing and packing of penicillin shall
be separate from those of other drugproduct for human use.
-
8/2/2019 Buildings and Facilities
21/31
Click to edit Master subtitle style
3/30/12
Placement of air inlet and outlet ports.Recirculation of air.
Alarm system and automatic cut-off systemis used ,where filter develops hole.In aseptic processing HEPA filters are used:
for filling and sealing operations:
a)less than100 particles of 0.5micron or larger,b)not more than one colony
forming organisms per cubic feet.
c)90 feet per minute arerecommended.
d)Requires a filter 99.97% DOPefficiency.
-
8/2/2019 Buildings and Facilities
22/31
Click to edit Master subtitle style
3/30/12
For solution compounding, equipmentand component preparation:
a) not more than 100,000particles of 0.5 microns or larger
b)not more than 25 colonyforming organisms per 10 cubic feet.
-
8/2/2019 Buildings and Facilities
23/31
Click to edit Master subtitle style
3/30/12
Plumbing:
Potable water shall meet the standardsprescribed in the Environmental ProtectionAgency's Primary Drinking WaterRegulations set forth in 40 CFR Part 141.
Drains shall be of adequate size and,where connected directly to a sewer, shallbe provided with an air break or othermechanical device to prevent back-siphonage
-
8/2/2019 Buildings and Facilities
24/31
Click to edit Master subtitle style
3/30/12
Sewage and refuse:
Sewage, trash, and other refuse in andfrom the building and immediatepremises shall be disposed of in a safe
and sanitary manner.A pharmaceutical plant may considerdisposal in several different ways:1. Product disposal
2. Printed packaging disposal3. General trash and sewage
-
8/2/2019 Buildings and Facilities
25/31
Click to edit Master subtitle style
3/30/12
WASHING AND TOILET
FACILITIESAdequate washing facilities shall beprovided, including hot and cold water,soap or detergent.
In addition to GMP regulations,Occupational Safety & HealthAdministration (OSHA) regulations impacton washing and toilet facilities.
-
8/2/2019 Buildings and Facilities
26/31
Click to edit Master subtitle style
3/30/12
Sanitation:
Any building used in themanufacture, processing, packing,or holding of drug product shouldmaintain clean and sanitary
condition.There should be writtenprocedures for use of suitableagents.
Manufacturing areas requireregular cleaning and disinfection .
-
8/2/2019 Buildings and Facilities
27/31
Click to edit Master subtitle style
3/30/12
Create and maintain a safe workingenvironment.
Remove dust and dirt, which can behazard to the quality.Minimize the risks of cross-contamination.Reduce levels of contamination micro-organismsEquipment used for cleaning
floor mopsvacuum cleanersmechanical floor cleanersjet cleaners
In general, the interval between twocleanin ro rams should not exceed 3
-
8/2/2019 Buildings and Facilities
28/31
Click to edit Master subtitle style
3/30/12
Maintenance:
Deterioration of building not only presentsa poor image of facility, it can also impacton product quality.The ingress of water from roof leaks can
cause damage to materials andequipment.Building inspection and maintenanceprograms should be defined in writing and
record kept for referencing any repairs
-
8/2/2019 Buildings and Facilities
29/31
Click to edit Master subtitle style
3/30/12
Conclusion:
It dictates the quality and compliance ofproducts that are to be manufactured andtheir profitability over the long run.
Therefore, these activities must beplanned in detail with the end in mindincluding the regulatory requirements forthe types of products according tointended commercial markets in additionto the facilitys country of location
-
8/2/2019 Buildings and Facilities
30/31
Click to edit Master subtitle style
3/30/12
References:
Q.A manual, buildings and facilities ,B.HShah, page no. 42-67.Pharmaceutical productions facilities,design and management, Graham
c.cole ,page no.13-18.Gmp for pharmaceutical, a plan for totalquality control, sidney H.willling, james R.stoker page no.43-61.
-
8/2/2019 Buildings and Facilities
31/31
Click icon to add pictur
3/30/12