Jaga Pro valve to the wall
Product code: BIUW.DBE
Built-in DBE
Dimensions
Connections
d H1
H
LL - 40
H1E
B58
HousingHousingConstruct the housing in such a way that the heat exchanger remains accessible for annual cleaning.
Hydraulic connection• Allconnectionsleftorrightareexchangeable
54
d H1
H
LL - 40
H1E
B58 Type B d E *H1
06 9.5 4.5 8 1010-11 11.5 5.5 10 1016 16.5 8 15 1221 21.5 10.5 20 15
Installation in a wall recess DBEDimensions
HousingConstruct the housing in such a way that the heat exchanger remains accessible for annual cleaning.
Dimensions in cm
*Smaller dimensions can decrease ouput.
Heat outputs are calculated on the given di-mensions and with free outlet of 75% of di-mension B. For other dimensions or grilles, correction factors have to be applied.
% air flow correction factor
75 1.00 60 0.96 50 0.92 40 0.84 30 0.66
Correction factors free air flow
Inst
alla
tion
in a
wal
l rec
ess D
BE
Dispatch in 15 days:Complete pre-assembled built-in with front and back panel reinforced in electrolytic gal-vanized steel plate.
Other models or dimensions:Only available as Special Product formajor projects.
Connections
Electric connection Outlet should be provided in the immediate vi-cinity in accordance with the applicable safety standards.Power 230 VAC/12VDC is supplied.In case of 12VDC supply, do not use the power supply provided.
Hydraulic connectionAll connections left or right are exchange-able.Detailed info: see Connection sets and valves.
2547
50
d 38
8
12
Jaga Pro valve to the wall Jaga Pro valve to the floor
Type d
06 4.6 10-11 5.2 15-16 7.7
Jaga type 6 valve to the wall
23
45
17
2.3
d
1.7
5
2.8
50
28
3.35
3350
The Jaga type 6 valve: with short connection distance, special for type 06 connection to the wall. Detailed info: see Connection sets and valves.
Brush
For easy cleaning of the Low-H2O heat exchanger.
CODE £
5090.001 6.70
Options
Communication softwareTo construct your own user pro�le see p. 64
5025
38
8
12
54
d H1
H
LL - 40
H1E
B58 Type B d E *H1
06 9.5 4.5 8 1010-11 11.5 5.5 10 1016 16.5 8 15 1221 21.5 10.5 20 15
Installation in a wall recess DBEDimensions
HousingConstruct the housing in such a way that the heat exchanger remains accessible for annual cleaning.
Dimensions in cm
*Smaller dimensions can decrease ouput.
Heat outputs are calculated on the given di-mensions and with free outlet of 75% of di-mension B. For other dimensions or grilles, correction factors have to be applied.
% air flow correction factor
75 1.00 60 0.96 50 0.92 40 0.84 30 0.66
Correction factors free air flow
Inst
alla
tion
in a
wal
l rec
ess D
BE
Dispatch in 15 days:Complete pre-assembled built-in with front and back panel reinforced in electrolytic gal-vanized steel plate.
Other models or dimensions:Only available as Special Product formajor projects.
Connections
Electric connection Outlet should be provided in the immediate vi-cinity in accordance with the applicable safety standards.Power 230 VAC/12VDC is supplied.In case of 12VDC supply, do not use the power supply provided.
Hydraulic connectionAll connections left or right are exchange-able.Detailed info: see Connection sets and valves.
2547
50
d 38
8
12
Jaga Pro valve to the wall Jaga Pro valve to the floor
Type d
06 4.6 10-11 5.2 15-16 7.7
Jaga type 6 valve to the wall
23
45
17
2.3
d
1.7
5
2.8
50
28
3.35
3350
The Jaga type 6 valve: with short connection distance, special for type 06 connection to the wall. Detailed info: see Connection sets and valves.
Brush
For easy cleaning of the Low-H2O heat exchanger.
CODE £
5090.001 6.70
Options
Communication softwareTo construct your own user pro�le see p. 64
5025
38
8
12
The Jaga type 6 valve has a short connection distance- special for type 06 connection to the wall
Electric connection• Outletshouldbeprovidedintheimmediatevicinityinaccordance with the applicable safety standards• Power230VAC/12VDCissupplied• Incaseof12VDCsupply,donotusethepowersupplyprovided
Heat outputs are calculated on the given dimensions and with free outlet of 75% of dimension B.
Forotherdimensionsorgrilles,correctionfactorshave to be applied.
Type B d E H1(min)
06 95 45 80 100
10-11 115 55 100 100
16 165 80 150 120
21 215 105 200 150
Correction factors free air flow
% air flow correction factor
75 1.00
60 0.96
50 0.92
40 0.84
30 0.66
Type d
06 46
10-11 52
15-16 77
Jaga Pro valve to the floor
Jaga Type 6 valve to the wall
54
d H1
H
LL - 40
H1E
B58 Type B d E *H1
06 9.5 4.5 8 1010-11 11.5 5.5 10 1016 16.5 8 15 1221 21.5 10.5 20 15
Installation in a wall recess DBEDimensions
HousingConstruct the housing in such a way that the heat exchanger remains accessible for annual cleaning.
Dimensions in cm
*Smaller dimensions can decrease ouput.
Heat outputs are calculated on the given di-mensions and with free outlet of 75% of di-mension B. For other dimensions or grilles, correction factors have to be applied.
% air flow correction factor
75 1.00 60 0.96 50 0.92 40 0.84 30 0.66
Correction factors free air flow
Inst
alla
tion
in a
wal
l rec
ess D
BE
Dispatch in 15 days:Complete pre-assembled built-in with front and back panel reinforced in electrolytic gal-vanized steel plate.
Other models or dimensions:Only available as Special Product formajor projects.
Connections
Electric connection Outlet should be provided in the immediate vi-cinity in accordance with the applicable safety standards.Power 230 VAC/12VDC is supplied.In case of 12VDC supply, do not use the power supply provided.
Hydraulic connectionAll connections left or right are exchange-able.Detailed info: see Connection sets and valves.
2547
50
d 38
8
12
Jaga Pro valve to the wall Jaga Pro valve to the floor
Type d
06 4.6 10-11 5.2 15-16 7.7
Jaga type 6 valve to the wall
23
45
17
2.3
d
1.7
5
2.8
50
28
3.35
3350
The Jaga type 6 valve: with short connection distance, special for type 06 connection to the wall. Detailed info: see Connection sets and valves.
Brush
For easy cleaning of the Low-H2O heat exchanger.
CODE £
5090.001 6.70
Options
Communication softwareTo construct your own user pro�le see p. 64
5025
38
8
12
Jaga Heating Products (UK) Ltd | www.jaga.co.ukT: +44 (0)1531 631 533 | F: +44 (0)1531 631 534 | [email protected]
Outputs in watts at 75/65/20°C, in accordance with EN442
Brush
Outputs
code height length type dbe OrDerCODe:BIUW 020 053 10DBe
code height length type dbe OrDerCODe:BIUW. 020 053 10DBe
H Type L 530 930 1330 1730
200 10 watts standby 393 655 917 1179 watts comfort 534 955 1217 1779 watts boost 643 1155 1417 2179
500 06 watts standby 568 947 1326 1705 watts comfort 703 1217 1596 2245 watts boost 793 1397 1776 2605
11 watts standby 832 1386 1940 2495 watts comfort 1132 1986 2540 3695 watts boost 1332 2386 2940 4495
16 watts standby 1139 1898 2657 3416 watts comfort 1619 2858 3617 5336 watts boost 1814 3248 4007 6116
21 watts standby 1549 2582 3615 4648 watts comfort 2029 3542 4575 6568 watts boost 2224 3932 4965 7348
H Type L 530 930 1330 1730
200 10 watts standby 191 318 446 573 watts comfort 326 573 730 1067 watts boost 386 693 850 1307
500 06 watts standby 341 568 796 1023 watts comfort 422 730 958 1347 watts boost 476 838 1066 1563
11 watts standby 399 665 931 1197 watts comfort 679 1192 1524 2217 watts boost 799 1432 1764 2697
16 watts standby 539 898 1258 1617 watts comfort 972 1715 2170 3202 watts boost 1088 1949 2404 3670
21 watts standby 725 1209 1693 2177 watts comfort 1217 2125 2745 3941 watts boost 1334 2359 2979 4409
(exampleordercodeshownisfora200mmhighradiator,530mmlong,type10)
(exampleordercodeshownisfora200mmhighradiator,530mmlong,type10)
• Low-H20heatexchanger
• Brackets
• extendedairvent1/8”
• Drainplug1/2”
Alldimensionsareshowninmillimetres
Options
OfferseasycleaningoftheundersideoftheLow-H2Oheatexchanger without the need to detach the casingOrder code:5090.001
Outputs in watts at 55/45/20°C, in accordance with EN442
OutputcalculatedinaccordancewitheN442,atawatertemperatureof75/65°Candaroomtemperatureof20°C(ΔT=50).
Supplied as Standard
Jaga Heating Products (UK) Ltd | www.jaga.co.ukT: +44 (0)1531 631 533 | F: +44 (0)1531 631 534 | [email protected]
Thermostatic heads
DW
Chrome/White
DC
Chrome
JA
White
JC
Silver
RM
remoteControlled
DS
Chrome/whiteremote sensor
Connection Sets
Connection to the wall - bottom of casing
Code Thermostatic head
COLO.PW2.DW.3... chrome/white
COLO.PW2.DC.3... chrome
COLO.PW2.JA.3... white 4
COLO.PW2.JC.3... silver
51
Two pipe
JagaProvalve
Thermostatic head of choice
Sleeve couplings M24
2curvestothewall
Set 11 Jaga Pro valve
Kv max. 0.6
Connection to the floor
JagaProvalve
Thermostatic head of choice
Sleeve couplings M24
Set 12 Jaga Pro valve
Code Thermostatic head
COLO.PF2.DW.3... chrome/white
COLO.PF2.DC.3... chrome
COLO.PF2.JA.3... white 4
COLO.PF2.JC.3... silver
51
Two pipeKv max. 0.6
Universal valve set for connection to the wall or to the floor Kv max. 0.6
Set 26 Jaga Comap valve
Code Thermostatic head
COLO.CP2.DW.4... chrome/white
COLO.CP2.DC.4... chrome
COLO.CP2.JA.4... white 4
COLO.CP2.JC.4... silver
51
Two pipe
Jaga Comapthermostatic valve
Thermostatic head of choice
Sleeve couplings Eurocone 3/4”
Connection to the wall - Not for Type 06 Kv max. 0.6
Set 21 Jaga valve
Code Thermostatic head
COLO.JW2.DW.2... chrome/white
COLO.JW2.DC.2... chrome
COLO.JW2.JA.2... white 4
COLO.JW2.JC.2... silver
51
Two pipe
Jaga thermostatic valve
Thermostatic head of choice
Sleeve couplings M24
Angledlockshield
The order code of the connection set will be completed with the sleeve coupling code
Jaga Heating Products (UK) Ltd | www.jaga.co.ukT: +44 (0)1531 631 533 | F: +44 (0)1531 631 534 | [email protected]
Connection to the floor Kv max. 0.6
Set 22 Jaga valve
Code Thermostatic head
COLO.JF2.DW.2... chrome/white
COLO.JF2.DC.2... chrome
COLO.JF2.JA.2... white 4
COLO.JF2.JC.2... silver
51
Two pipe
Jaga thermostatic valve
Thermostatic head of choice
Sleeve couplings M24
Straight lockshield
Connection to the floor Kv max. 0.6
Set 23 Jaga valve
Code Thermostatic head
COLO.JW3.DW.2... chrome/white
COLO.JW3.DC.2... chrome
COLO.JW3.JA.2... white 4
COLO.JW3.JC.2... silver
51
Two pipe
Jaga thermostatic valve Thermostatic head of choice
extensionpipe
Sleeve couplings M24
H-piece angled
Connection to the floor Kv max. 0.6
Set 24 Jaga valve
Code Thermostatic head
COLO.JF3.DW.2... chrome/white
COLO.JF3.DC.2... chrome
COLO.JF3.JA.2... white 4
COLO.JF3.JC.2... silver
51
Two pipe
extensionpipe
Jaga thermostatic valve
Thermostatic head of choice
Sleeve couplings M24
H-piece straight
Thermostatic heads
DW
Chrome/White
DC
Chrome
JA
White
JC
Silver
RM
remoteControlled
DS
Chrome/whiteremote sensor
Connection to the wall within the casing - for Type 06 Kv max. 0.6
Jaga Type 6 thermostatic valve
Thermostatic head of choice
Sleeve couplings M24
Angledlockshield
Set 25 Jaga Type 6 valve
Code Thermostatic head
COLO.SW2.DW.3... chrome/white
COLO.SW2.DC.3... chrome
COLO.SW2.JA.3... white 4
COLO.SW2.JC.3... silver
51
Two pipe
The order code of the connection set will be completed with the sleeve coupling code
Jaga Heating Products (UK) Ltd | www.jaga.co.ukT: +44 (0)1531 631 533 | F: +44 (0)1531 631 534 | [email protected]
For flexible steel or copper tube Ø 15mm
Code 5090.1120
Pro Key
Tool for easy mounting of the JagaProvalve.
Code Tube Ø
112 12/1
114 14/1
115 15/1
116 16/1
118 18/1
For Jaga Comap valve - Eurocone 3/4”
Code Tube Ø
612 12/2
614 14/2
616 16/2
617 17/2
618 18/2
615 15/2.5
619 16/1.5
620 20/2
For flexible steel or copper tubeFor synthetic or RPE/ALU tube
3/4”M 243/4”
Fort
ube
12/2
onl
y
Sleeve Couplings
Code Tube Ø
314 14/2
316 16/2
326 16/2.2
318 18/2
Code Tube Ø
501 1/2”
503 3/8”
Steel tube for CHFor RPE/ALU tube
Code Tube Ø
110 10/1
112 12/1
114 14/1
115 15/1
116 16/1
118 18/1
For flexible steel or copper tube
1/2”
1/2”
1/2”
Fort
ube
18/1
onl
y
Fort
ube
15/1
onl
y
Code Tube Ø
212 12/2
214 14/2
219 16/1.5
216 16/2
217 17/2
218 18/2
For synthetic tube
1/2”
1/2”
1/2”
For Jaga valve - M24
Short Coupling - for Connection to the wall
Code Tube Ø
125 15/1
1/2"1/2”
Complete ordering code with sleeve couplings according to the material used and diameter of the tube. The correct type of sleeve coupling is determined by the ordering code of the connection set
Example: COLO.PW2.DW.32.(insertrelevantcodefromabove)
Includedinthepriceoftheconnectionsets
Jaga Heating Products (UK) Ltd | www.jaga.co.ukT: +44 (0)1531 631 533 | F: +44 (0)1531 631 534 | [email protected]
Average correction factors according - 75/65/20°C for Comfort and Boost mode
Tv Tl Tr > 20 25 30 35 40 45 50 55 60 65 70 75 80 85
90 20 0.70 0.75 0.80 0.85 0.90 0.95 1.00 1.05 1.10 1.15 1.20 1.25 1.30 1.35 24 0.62 0.67 0.72 0.77 0.82 0.87 0.92 0.97 1.02 1.07 1.12 1.17 1.22 1.3285 20 0.65 0.70 0.75 0.80 0.85 0.90 0.95 1.00 1.05 1.10 1.15 1.20 1.25 24 0.57 0.62 0.67 0.72 0.77 0.82 0.87 0.92 0.97 1.02 1.07 1.12 1.1780 20 0.60 0.65 0.70 0.75 0.80 0.85 0.90 0.95 1.00 1.05 1.10 1.15 24 0.52 0.57 0.62 0.67 0.72 0.77 0.82 0.87 0.92 0.97 1.02 1.07 75 20 0.55 0.60 0.65 0.70 0.75 0.80 0.85 0.90 0.95 1.00 1.05 24 0.47 0.52 0.57 0.62 0.67 0.72 0.77 0.82 0.87 0.92 0.95 70 20 0.50 0.55 0.60 0.65 0.70 0.75 0.80 0.85 0.90 0.95 24 0.42 0.47 0.52 0.57 0.62 0.67 0.72 0.77 0.82 0.87 65 20 0.45 0.50 0.55 0.60 0.65 0.70 0.75 0.80 0.85 24 0.37 0.42 0.47 0.52 0.57 0.62 0.67 0.72 0.77 60 20 0.40 0.45 0.50 0.55 0.60 0.65 0.70 0.75 24 0.32 0.37 0.42 0.47 0.52 0.57 0.62 0.67 55 20 0.35 0.40 0.45 0.50 0.55 0.60 0.65 24 0.27 0.32 0.37 0.42 0.47 0.52 0.57 50 20 0.30 0.35 0.40 0.45 0.50 0.55 24 0.22 0.27 0.32 0.37 0.42 0.47 45 20 0.25 0.30 0.35 0.40 0.45 24 0.17 0.22 0.27 0.32 0.3740 20 0.20 0.25 0.30 0.35 24 0.12 0.17 0.22 0.2735 20 0.15 0.20 0.25 24 0.07 0.12 0.1730 20 0.10 0.15 24 0.02 0.07
DBE Correction factors
Insulation 20° 24°
excellent 45 55
good 65 75
average 85 95
poor 100 115
requiredoutputinWatts/m³
Average correction factors according to EN442 - 75/65/20°C for Comfort and Boost mode
How to choose the right radiator?
Correction factors
Rapid estimation of heat lossesCalculatethevolumeoftheroom(LxWxH)andmultiplythisbytheWatts/m³figuregiveninthetablebelow. Choose according to the level of insulation and the desired room temperature.
ExampleUsethetabletodeterminetherelevantcorrectionfactorwithawatertemperatureof60/45°cwitharoomtemperatureof20°C.
The correction factor = 0.65
requiredoutput1000watts:1000dividedby0.65=1538wattstherefore search in this leaflet’s standard output table for a product with anoutputofatleast1538watts.Alternativelyusethe“radiatorFinder”search function on www.jaga.co.uk to identify all Jaga heating products withthisrequiredoutput.
OutputcalculatedinaccordancewitheN442,atawatertemperatureof75/65°Candaroomtemperatureof20°C(ΔT=50).
The indicated outputs with ∆T50°caretheexactoutputsandarecalculatedinaccordancewitheN442.Anaveragecorrectionfactorisgiveninthistableforoutputsatother∆T and is applicable for all dimensions.
KEYTv = flow temperature
Tr = return temperatureTl = desired air temperature
Jaga Heating Products (UK) Ltd | www.jaga.co.ukT: +44 (0)1531 631 533 | F: +44 (0)1531 631 534 | [email protected]
Sound pressure and correction factors CombinedsoundlevelofmultipleDBeunits
1 4 8 12 16 20 24 28 32 36 40
0
2
4
6
8
10
12
14
16
Incr
ease
of s
ound
pre
ssur
e dB
(A)
Number of fan modules
Type db(A)
Comfort Boost
11 29 35
16 27 31
Numberdb(A)
Correctiondb(A)
2 +3.0
3 +4.8
Several appliances with an equal sound level in a room
P2=P1+10lognP1=soundleveloneapplianceP2=soundleveltobecalculatedn = number of appliances
ThroughtheDBe-communicationsoftware(DBeD)itispossibletosetupotheractivatorspeeds.Inthiswayyoucanobtainotheroutputsandsoundpressures.Formoreinformation,contactJaga.
Forreferenceatypicalconversationhasadblevelof60,amotorbikeis105dbandarockconcert140db.
Volume(m3)
Correctiondb(A)
80 0
150 -2.7
200 -4.0
250 -4.9
300 -5.7
350 -6.4
400 -7.0
500 -8.0
600 -8.8
V2P2=P1-10log V1
P1=tableofsoundpressureP2=soundleveltobecalculatedV1=sizeofroomofreference(80m³)V2=otherroomsize
Correction factor by room volume
Equation for calculating sound pressure in other room sizes
Correction factors
Acoustic Data
Jaga Heating Products (UK) Ltd | www.jaga.co.ukT: +44 (0)1531 631 533 | F: +44 (0)1531 631 534 | [email protected]
Type 06Pressure drop type 06
L = 60L = 120L = 240 L = 220L = 180ΔP
[bar]ΔP ΔP
[kPa]1000
100
800600
1
300
200
500400
8060
30
2015
5040
1086
3
22.5
1.5
54
0.1
0.01
0.080.06
0.0001
0.03
0.02
0.050.04
0.0080.006
0.003
0.002
0.0050.004
0.0010.00080.0006
0.0003
0.0002
0.00050.0004
10
1
86
0.01
3
2
54
0.80.6
0.3
0.2
0.50.4
0.10.080.06
0.03
0.02
0.050.04
30 4050 70 100 200 300400500 70010002010
kW
kW
kW
t=15 °C
t=20 °C
t=40 °C
t=10 °C 0,5 1 kW0,15 6,0 8,04,03,02,0 5 101,5 6 8432
0,5 10,2 0,3 0,8 5 101,5 6 8432
16,0 8,04,03,0 5 101,5 6 8432
0,5 16,0 8,0 5 101,5 6 8432
Pres
sure
dro
p in
mm
WC
/ ba
r / k
Pa
Water flow in kg/h
[mmWC]
Pressure drop type 10 Pressure drop type 11
L = 60L = 120L= 180L =240
ΔP[bar]
ΔP[mmWs]
1000
100
150
800600
1
300
200
500400
8060
30
2015
5040
1086
3
22.5
1.5
54
0.1
0.01
0.080.06
0.0001
0.03
0.02
0.050.04
0.0080.006
0.003
0.002
0.0050.004
0.0010.00080.0006
0.0003
0.0002
0.00050.0004
30 4050 70 100 200 300400500 70010002010
kW
kW
kW
t=15 °C
t=20 °C
t=40 °C
t=10 °C 0,5 1 kW0,15 6,0 8,04,03,02,0 5 101,5 6 8432
0,5 10,2 0,3 0,8 5 101,5 6 8432
16,0 8,04,03,0 5 101,5 6 8432
0,5 16,0 8,0 5 101,5 6 8432
ΔP[kPa]
10
1
1.5
86
0.01
3
2
54
0.80.6
0.3
0.2
0.50.4
0.10.080.06
0.03
0.02
0.050.04
Pres
sure
dro
p in
mm
WC
/ ba
r / k
Pa
Water flow in kg/h
[mmWC]
L = 60L = 120
L = 180L = 240ΔP[bar]
ΔP[mmWs]
ΔP[kPa]
1000
100
150
800600
1
300
200
500400
8060
30
2015
5040
1086
3
22.5
1.5
54
0.1
0.01
0.080.06
0.0001
0.03
0.02
0.050.04
0.0080.006
0.003
0.002
0.0050.004
0.0010.00080.0006
0.0003
0.0002
0.00050.0004
10
1
1.5
86
0.01
3
2
54
0.80.6
0.3
0.2
0.50.4
0.10.080.06
0.03
0.02
0.050.04
30 4050 70 100 200 300400500 70010002010
kW
kW
kW
t=15 °C
t=20 °C
t=40 °C
t=10 °C 0,5 1 kW0,15 6,0 8,04,03,02,0 5 101,5 6 8432
0,5 10,2 0,3 0,8 5 101,5 6 8432
16,0 8,04,03,0 5 101,5 6 8432
0,5 16,0 8,0 5 101,5 6 8432
Pres
sure
dro
p in
mm
WC
/ ba
r / k
Pa
Water flow in kg/h
[mmWC]
Pressure drop type 16
ΔP[bar]
ΔP[mmWs]
1000
100
150
800600
1
300
200
500400
8060
30
2015
5040
1086
3
22.5
1.5
54
0.1
0.01
0.080.06
0.0001
0.03
0.02
0.050.04
0.0080.006
0.003
0.002
0.0050.004
0.0010.00080.0006
0.0003
0.0002
0.00050.0004
30 4050 70 100 200 300400500 70010002010
L = 60L = 120L = 180
L = 240ΔP[kPa]
10
1
1.5
86
0.01
3
2
54
0.80.6
0.3
0.2
0.50.4
0.10.080.06
0.03
0.02
0.050.04
kW
kW
kW
t=15 °C
t=20 °C
t=40 °C
t=10 °C 0,5 1 kW0,15 6,0 8,04,03,02,0 5 101,5 6 8432
0,5 10,2 0,3 0,8 5 101,5 6 8432
16,0 8,04,03,0 5 101,5 6 8432
0,5 16,0 8,0 5 101,5 6 8432
Pres
sure
dro
p in
mm
WC
/ ba
r / k
Pa
Water flow in kg/h
[mmWC]
Pressure drop type 15
P[bar]
P[mmWs]
P[kPa]
1000
100
150
800600
1
300
200
500400
8060
30
2015
5040
1086
3
22.5
1.5
54
0.1
0.01
0.080.06
0.0001
0.03
0.02
0.050.04
0.0080.006
0.003
0.002
0.0050.004
0.0010.00080.0006
0.0003
0.0002
0.00050.0004
10
1
1.5
86
0.01
3
2
54
0.80.6
0.3
0.2
0.50.4
0.10.080.06
0.03
0.02
0.050.04
30 4050 70 100 200 300400500 70010002010
kW
kW
kW
t=15 °C
t=20 °C
t=40 °C
t=10 °C 0,5 1 kW0,15 6,0 8,04,03,02,0 5 101,5 6 8432
0,5 10,2 0,3 0,8 5 101,5 6 8432
16,0 8,04,03,0 5 101,5 6 8432
0,5 16,0 8,0 5 101,5 6 8432
L = 60L = 120L = 180L = 220L = 240
Pres
sure
dro
p in
mm
WC
/ ba
r / k
Pa
Water flow in kg/h
[mmWC]
Pressure drops
Type 10 Type 11
Type 16
Pressure drop type 06
L = 60L = 120L = 240 L = 220L = 180ΔP
[bar]ΔP ΔP
[kPa]1000
100
800600
1
300
200
500400
8060
30
2015
5040
1086
3
22.5
1.5
54
0.1
0.01
0.080.06
0.0001
0.03
0.02
0.050.04
0.0080.006
0.003
0.002
0.0050.004
0.0010.00080.0006
0.0003
0.0002
0.00050.0004
10
1
86
0.01
3
2
54
0.80.6
0.3
0.2
0.50.4
0.10.080.06
0.03
0.02
0.050.04
30 4050 70 100 200 300400500 70010002010
kW
kW
kW
t=15 °C
t=20 °C
t=40 °C
t=10 °C 0,5 1 kW0,15 6,0 8,04,03,02,0 5 101,5 6 8432
0,5 10,2 0,3 0,8 5 101,5 6 8432
16,0 8,04,03,0 5 101,5 6 8432
0,5 16,0 8,0 5 101,5 6 8432
Pres
sure
dro
p in
mm
WC
/ ba
r / k
Pa
Water flow in kg/h
[mmWC]
Pressure drop type 10 Pressure drop type 11
L = 60L = 120L= 180L =240
ΔP[bar]
ΔP[mmWs]
1000
100
150
800600
1
300
200
500400
8060
30
2015
5040
1086
3
22.5
1.5
54
0.1
0.01
0.080.06
0.0001
0.03
0.02
0.050.04
0.0080.006
0.003
0.002
0.0050.004
0.0010.00080.0006
0.0003
0.0002
0.00050.0004
30 4050 70 100 200 300400500 70010002010
kW
kW
kW
t=15 °C
t=20 °C
t=40 °C
t=10 °C 0,5 1 kW0,15 6,0 8,04,03,02,0 5 101,5 6 8432
0,5 10,2 0,3 0,8 5 101,5 6 8432
16,0 8,04,03,0 5 101,5 6 8432
0,5 16,0 8,0 5 101,5 6 8432
ΔP[kPa]
10
1
1.5
86
0.01
3
2
54
0.80.6
0.3
0.2
0.50.4
0.10.080.06
0.03
0.02
0.050.04
Pres
sure
dro
p in
mm
WC
/ ba
r / k
Pa
Water flow in kg/h
[mmWC]
L = 60L = 120
L = 180L = 240ΔP[bar]
ΔP[mmWs]
ΔP[kPa]
1000
100
150
800600
1
300
200
500400
8060
30
2015
5040
1086
3
22.5
1.5
54
0.1
0.01
0.080.06
0.0001
0.03
0.02
0.050.04
0.0080.006
0.003
0.002
0.0050.004
0.0010.00080.0006
0.0003
0.0002
0.00050.0004
10
1
1.5
86
0.01
3
2
54
0.80.6
0.3
0.2
0.50.4
0.10.080.06
0.03
0.02
0.050.04
30 4050 70 100 200 300400500 70010002010
kW
kW
kW
t=15 °C
t=20 °C
t=40 °C
t=10 °C 0,5 1 kW0,15 6,0 8,04,03,02,0 5 101,5 6 8432
0,5 10,2 0,3 0,8 5 101,5 6 8432
16,0 8,04,03,0 5 101,5 6 8432
0,5 16,0 8,0 5 101,5 6 8432
Pres
sure
dro
p in
mm
WC
/ ba
r / k
Pa
Water flow in kg/h
[mmWC]
Pressure drop type 16
ΔP[bar]
ΔP[mmWs]
1000
100
150
800600
1
300
200
500400
8060
30
2015
5040
1086
3
22.5
1.5
54
0.1
0.01
0.080.06
0.0001
0.03
0.02
0.050.04
0.0080.006
0.003
0.002
0.0050.004
0.0010.00080.0006
0.0003
0.0002
0.00050.0004
30 4050 70 100 200 300400500 70010002010
L = 60L = 120L = 180
L = 240ΔP[kPa]
10
1
1.5
86
0.01
3
2
54
0.80.6
0.3
0.2
0.50.4
0.10.080.06
0.03
0.02
0.050.04
kW
kW
kW
t=15 °C
t=20 °C
t=40 °C
t=10 °C 0,5 1 kW0,15 6,0 8,04,03,02,0 5 101,5 6 8432
0,5 10,2 0,3 0,8 5 101,5 6 8432
16,0 8,04,03,0 5 101,5 6 8432
0,5 16,0 8,0 5 101,5 6 8432
Pres
sure
dro
p in
mm
WC
/ ba
r / k
Pa
Water flow in kg/h
[mmWC]
Pressure drop type 15
P[bar]
P[mmWs]
P[kPa]
1000
100
150
800600
1
300
200
500400
8060
30
2015
5040
1086
3
22.5
1.5
54
0.1
0.01
0.080.06
0.0001
0.03
0.02
0.050.04
0.0080.006
0.003
0.002
0.0050.004
0.0010.00080.0006
0.0003
0.0002
0.00050.0004
10
1
1.5
86
0.01
3
2
54
0.80.6
0.3
0.2
0.50.4
0.10.080.06
0.03
0.02
0.050.04
30 4050 70 100 200 300400500 70010002010
kW
kW
kW
t=15 °C
t=20 °C
t=40 °C
t=10 °C 0,5 1 kW0,15 6,0 8,04,03,02,0 5 101,5 6 8432
0,5 10,2 0,3 0,8 5 101,5 6 8432
16,0 8,04,03,0 5 101,5 6 8432
0,5 16,0 8,0 5 101,5 6 8432
L = 60L = 120L = 180L = 220L = 240
Pres
sure
dro
p in
mm
WC
/ ba
r / k
Pa
Water flow in kg/h
[mmWC]
Type 21
Pressure drop type 06
L = 60L = 120L = 240 L = 220L = 180ΔP
[bar]ΔP ΔP
[kPa]1000
100
800600
1
300
200
500400
8060
30
2015
5040
1086
3
22.5
1.5
54
0.1
0.01
0.080.06
0.0001
0.03
0.02
0.050.04
0.0080.006
0.003
0.002
0.0050.004
0.0010.00080.0006
0.0003
0.0002
0.00050.0004
10
1
86
0.01
3
2
54
0.80.6
0.3
0.2
0.50.4
0.10.080.06
0.03
0.02
0.050.04
30 4050 70 100 200 300400500 70010002010
kW
kW
kW
t=15 °C
t=20 °C
t=40 °C
t=10 °C 0,5 1 kW0,15 6,0 8,04,03,02,0 5 101,5 6 8432
0,5 10,2 0,3 0,8 5 101,5 6 8432
16,0 8,04,03,0 5 101,5 6 8432
0,5 16,0 8,0 5 101,5 6 8432
Pres
sure
dro
p in
mm
WC
/ ba
r / k
Pa
Water flow in kg/h
[mmWC]
Pressure drop type 10 Pressure drop type 11
L = 60L = 120L= 180L =240
ΔP[bar]
ΔP[mmWs]
1000
100
150
800600
1
300
200
500400
8060
30
2015
5040
1086
3
22.5
1.5
54
0.1
0.01
0.080.06
0.0001
0.03
0.02
0.050.04
0.0080.006
0.003
0.002
0.0050.004
0.0010.00080.0006
0.0003
0.0002
0.00050.0004
30 4050 70 100 200 300400500 70010002010
kW
kW
kW
t=15 °C
t=20 °C
t=40 °C
t=10 °C 0,5 1 kW0,15 6,0 8,04,03,02,0 5 101,5 6 8432
0,5 10,2 0,3 0,8 5 101,5 6 8432
16,0 8,04,03,0 5 101,5 6 8432
0,5 16,0 8,0 5 101,5 6 8432
ΔP[kPa]
10
1
1.5
86
0.01
3
2
54
0.80.6
0.3
0.2
0.50.4
0.10.080.06
0.03
0.02
0.050.04
Pres
sure
dro
p in
mm
WC
/ ba
r / k
Pa
Water flow in kg/h
[mmWC]
L = 60L = 120
L = 180L = 240ΔP[bar]
ΔP[mmWs]
ΔP[kPa]
1000
100
150
800600
1
300
200
500400
8060
30
2015
5040
1086
3
22.5
1.5
54
0.1
0.01
0.080.06
0.0001
0.03
0.02
0.050.04
0.0080.006
0.003
0.002
0.0050.004
0.0010.00080.0006
0.0003
0.0002
0.00050.0004
10
1
1.5
86
0.01
3
2
54
0.80.6
0.3
0.2
0.50.4
0.10.080.06
0.03
0.02
0.050.04
30 4050 70 100 200 300400500 70010002010
kW
kW
kW
t=15 °C
t=20 °C
t=40 °C
t=10 °C 0,5 1 kW0,15 6,0 8,04,03,02,0 5 101,5 6 8432
0,5 10,2 0,3 0,8 5 101,5 6 8432
16,0 8,04,03,0 5 101,5 6 8432
0,5 16,0 8,0 5 101,5 6 8432Pr
essu
re d
rop
in m
mW
C /
bar /
kPa
Water flow in kg/h
[mmWC]
Pressure drop type 16
ΔP[bar]
ΔP[mmWs]
1000
100
150
800600
1
300
200
500400
8060
30
2015
5040
1086
3
22.5
1.5
54
0.1
0.01
0.080.06
0.0001
0.03
0.02
0.050.04
0.0080.006
0.003
0.002
0.0050.004
0.0010.00080.0006
0.0003
0.0002
0.00050.0004
30 4050 70 100 200 300400500 70010002010
L = 60L = 120L = 180
L = 240ΔP[kPa]
10
1
1.5
86
0.01
3
2
54
0.80.6
0.3
0.2
0.50.4
0.10.080.06
0.03
0.02
0.050.04
kW
kW
kW
t=15 °C
t=20 °C
t=40 °C
t=10 °C 0,5 1 kW0,15 6,0 8,04,03,02,0 5 101,5 6 8432
0,5 10,2 0,3 0,8 5 101,5 6 8432
16,0 8,04,03,0 5 101,5 6 8432
0,5 16,0 8,0 5 101,5 6 8432
Pres
sure
dro
p in
mm
WC
/ ba
r / k
Pa
Water flow in kg/h
[mmWC]
Pressure drop type 15
P[bar]
P[mmWs]
P[kPa]
1000
100
150
800600
1
300
200
500400
8060
30
2015
5040
1086
3
22.5
1.5
54
0.1
0.01
0.080.06
0.0001
0.03
0.02
0.050.04
0.0080.006
0.003
0.002
0.0050.004
0.0010.00080.0006
0.0003
0.0002
0.00050.0004
10
1
1.5
86
0.01
3
2
54
0.80.6
0.3
0.2
0.50.4
0.10.080.06
0.03
0.02
0.050.04
30 4050 70 100 200 300400500 70010002010
kW
kW
kW
t=15 °C
t=20 °C
t=40 °C
t=10 °C 0,5 1 kW0,15 6,0 8,04,03,02,0 5 101,5 6 8432
0,5 10,2 0,3 0,8 5 101,5 6 8432
16,0 8,04,03,0 5 101,5 6 8432
0,5 16,0 8,0 5 101,5 6 8432
L = 60L = 120L = 180L = 220L = 240
Pres
sure
dro
p in
mm
WC
/ ba
r / k
Pa
Water flow in kg/h
[mmWC]
Jaga Heating Products (UK) Ltd | www.jaga.co.ukT: +44 (0)1531 631 533 | F: +44 (0)1531 631 534 | [email protected]
1Theguaranteeisvalidonlyiftheequipmentisproperlyandcorrectlyused,byitsfirstownerandifinstalledinaccordancewiththenorms
and instructions as detailed in the instruction leaflet and current industry standard practices.
2The guarantee only applies to the equipment and the spare partssupplied by Jaga. Jaga has the choice between repair and replacement
oftheequipmentorthespareparts.IfanymodificationshavebeenmadebyJagatothestandardproductdesign,Jagareservestherighttoreplacetheguaranteedequipmentwithequivalentproductsorspareparts.
3Theperiodofguaranteeismentionedinthiscertificate.Theguaranteedecreaseseveryyearonastraightlinebasisbyanequalpercentage
inordertoreachazeroguaranteeattheendoftheguaranteeperiod(e.g.foraperiodof10yearstheannualdecreaseoftheguarantees10%oftheinvoicedvalue).repairedorreplacedproductisguaranteedthroughtotheend of the original guarantee period.
4 The guarantee is valid only on products displaying the appropriate identification information concerning product type and series. No
guaranteeisgrantedonequipmentorsparepartslackingthisinformation,onequipmentwherethisinformationhasbeenremovedoraltered,oronequipmentthathasbeenrepairedormodifiedbypersonsnotauthorisedby Jaga to carry out this work.
5 The customer is responsible for any damage caused as a result of errors in installationoruseof incorrectfittings,or foranydamage
causedbyelectricalconnections,faultyordamagedelectricalinstallationsorappliances,erroneousvoltageorhydraulicpressureandallothererrorsnot directly related to the product delivered by Jaga. The guarantee is also revoked when unsuitable parts or components are used. The guarantee for ourheatexchangersisnotvalidiftheyareregularlydrained,oriftheyareheatedbymeansofindustrialwater,steamorwatersaturatedbyexcessivequantitiesofoxygen.ThequalityofthesystematerhastobeinaccordancewiththeVDI2035-2directives.Theguaranteeisalsonotapplicableiftheheatexchangersareplacedinunsuitableatmosphericsurroundings,suchasbutnotexclusivelyammonia,causticsubstancesetc.
6 Thisguaranteeexcludesdamageduetoincorrecthandlingand/oruseoftheequipment,orduetoformationoflimedeposits,incorrectuse
ofthesafetyvalve,ortoallequipmentthatisincorporatedintothebuildingin a way that means it cannot be accessed normally.
7 Anyworkundertakenorproductsuppliedasaresultofaguaranteeclaimthatprovesnottobevalidwillbechargedfor.Productsupplied
willbeinvoicedatthecustomer’sstandardpurchasingterms,andlabourwillbechargedat£50perhourwithaminimumlabourchargeof£200.
8 The guarantee period starts from the date of the invoice for supply of theproductscoveredbytheguarantee.Iftheinvoiceisnotavailable,
thedateofproductionwillbeusedbasedontheproductIDnumber/series.
9 OnlythecourtsofjudicialdistrictHasselt(Belgium)areauthorisedtodealwithdisputesarisingfromthisguarantee.ItwillapplyBelgian
lawevenwhensalesinvolvedaresubjectsofeUmemberstatesaswellasnon-eUmembercountries.
Jaga Guarantee information
Heat exchanger
Casings and components
Valves for Low-H2O heat exchangers