bulletin osc okonite cables - the okonite company · mc metal-clad cable. nec type designa - tion...
TRANSCRIPT
Bulletin OSC
OKONITE CABLES
102 Hilltop Road, Ramsey, New Jersey 07446 Phone 201.825.0300 www.okonite.com• •
THEOKONITECOMPANY
STOCK CATALOGIn Stock for Immediate Delivery
▲“ ”
INDEX
Data SheetSection:Sheet
GLOSSARY OF TERMS AND DEFINITIONS
MEDIUM VOLTAGE POWER CABLES 2.4kV AND ABOVESingle Conductor CableOkoguard Non-Shielded Okolon TS-CPE Type MV-90 (CT USE) 2.4kV ......................2:2
Okoguard Shielded Okoseal Type MV-105 (CT USE) 5/8kV ........................................2:3
Okoguard Shielded Okoseal Type MV-105 5/8 kV.........................................................2:4
Okoguard Shielded Okoseal Type MV-105 (CT USE) 15kV .........................................2:8
Okoguard Shielded Okoseal Type MV-105 15kV ..........................................................2:9
Okoguard Shielded Okolon TS-CPE Type MV-105 (CT USE) 15kV .............................2:11
Okoguard Shielded Okoseal Type MV-105 35kV...........................................................2:16
Okoguard Shielded Okoseal 69kV ................................................................................2:18
Multi-Conductor CableOkoguard Shielded Okoseal Type MV-105 (CT USE) 3/C 5/8kV ..................................2:19
Okoguard Shielded Okoseal Type MV-105 (CT USE) 3/C 15kV ...................................2:20
Okoguard Non-Shielded C-L-X Type MV-90 or MC-HL (CT USE) 2.4kV ......................2:21
Okoguard Shielded C-L-X Type MV-105 or MC-HL (CT USE) 5/8kV ...........................2:22
Okoguard Shielded C-L-X Type MV-105 or MC-HL (CT USE) 15kV ............................2:24
Solid Type PILC 3/C 15kV..............................................................................................2:31
UNDERGROUND RESIDENTIAL DISTRIBUTION CABLEOkoguard URO-J 15kV...................................................................................................2:35
Okoguard URO-J 15kV Filled Strand .............................................................................2:36
Okoguard URO-J 25kV...................................................................................................2:39
Okoguard URO-J 35kV...................................................................................................2:40
LOW VOLTAGE CABLES TO 2kVSingle Conductor CableOkoguard Okolon TS-CPE Type RHH or RHW-2 or USE-2, VW-1 600V RW-90 .........3:1
Okoguard Okolon TS-CPE Type RHH or RHW-2, 2000V .............................................3:10
Multi-Conductor CableC-L-X Type MC-HL for CT USE (XHHW-2) 600V .........................................................4:1
C-L-X Type MC (XHHW-2) 600V....................................................................................4:2
Okonite-FMR Okoseal Type TC 600V............................................................................4:5
X-Olene - Okoseal Type TC-ER Control Cable (XHHW-2) 600V ...................................4:8
C-L-X Type MC for CT USE (XHHW-2) 600V Control Cable ........................................4:14
C-L-X Type MC-HL for CT USE (XHHW-2) 600V Control Cable ..................................4:15
INDEX
Data SheetSection:Sheet
INSTRUMENTATION CABLESOkoseal Type P-OS 300V .............................................................................................5:2
Okoseal Type P-OS C-L-X 300V ...................................................................................5:3
Type SP-OS Instrumentation Cbale ...............................................................................5:13
Okoseal Type SP-OS C-L-X 300V ................................................................................5:14
Okoseal Type P-OS Thermocouple 300V .....................................................................5:18
C-L-X Okoseal Type P-OS Thermocouple 300V............................................................5:19
Okoseal-N Type P-OS 600V .........................................................................................5:29
Okoseal-N Type SP-OS 600V .......................................................................................5:31
Okoseal-N Type P-OS C-L-X Type MC-HL 600V .........................................................5:40
Okoseal-N Type SP-OS C-L-X Type MC-HL 600V ......................................................5:42
Okobus Type PLTC & Type ITC-ER Fieldbus CableSingle Pair Type P-OS — Multi Pair Type SP-OS..........................................................5:47
Okobus C-L-X.................................................................................................................5:48
C-L-X X-Olene P-OS, SP-OS .........................................................................................5:49
SPECIAL PURPOSE CABLESX-Ray Low Noise 65-250kV DC .....................................................................................6:1
X-Ray 65-1000kV DC .....................................................................................................6:2
Okoguard Aerial Jumper Cable 15kV ............................................................................6:4
Okoguard-Okolon TS-CPE 5kV Airport Lighting Cable ..................................................6:6
RAILROAD AND TRANSIT SYSTEM CABLESArmored Signal Cable ....................................................................................................7:1
Track Wire .....................................................................................................................7:6
Tower and Case Wire ....................................................................................................7:10
Case Wire ......................................................................................................................7:11
Nylon Braid Case Wire ..................................................................................................7:12
Type DEL........................................................................................................................7:17
SPLICING AND TERMINATING PRODUCTSC-L-X Terminating Tool Kit ............................................................................................ 6:5
Color Code Tables ......................................................................................................... OSL
Miscellaneous Information ............................................................................................. OSL
OSC Index 02/15
INDEX
Okoseal Type P-OS 300V .............................................................................................5:2
Okoseal Type P-OS C-L-X 300V ...................................................................................5:3
Type SP-OS Instrumentation Cbale ...............................................................................5:13
Okoseal Type SP-OS C-L-X 300V ................................................................................5:14
Okoseal Type P-OS Thermocouple 300V .....................................................................5:18
C-L-X Okoseal Type P-OS Thermocouple 300V............................................................5:19
Okoseal-N Type P-OS 600V .........................................................................................5:29
Okoseal-N Type SP-OS 600V .......................................................................................5:31
Okoseal-N Type P-OS C-L-X Type MC-HL 600V .........................................................5:40
Okoseal-N Type SP-OS C-L-X Type MC-HL 600V ......................................................5:42
Okobus Type PLTC & Type ITC-ER Fieldbus CableSingle Pair Type P-OS — Multi Pair Type SP-OS..........................................................5:47
Okobus C-L-X.................................................................................................................5:48
X-Ray Low Noise 65-250kV DC .....................................................................................6:1
X-Ray 65-100kV DC .......................................................................................................6:2
Okoguard Aerial Jumper Cable 15kV ............................................................................6:4
Okoguard-Okolon TS-CPE 5kV Airport Lighting Cable ..................................................6:6
Armored Signal Cable ....................................................................................................7:1
Track Wire .....................................................................................................................7:6
Tower and Case Wire ....................................................................................................7:10
Case Wire ......................................................................................................................7:11
Nylon Braid Case Wire ..................................................................................................7:12
Type DEL........................................................................................................................7:17
C-L-X Terminating Tool Kit ............................................................................................ 6:5
Color Code Tables ......................................................................................................... OSL
Miscellaneous Information ............................................................................................. OSL
OSC Index 02/15
INDUSTRY ASSOCIATIONS
ABS American Bureau of Shipping.
AEIC Association of Edison
Illuminating Companies.
ANSI American National Standards
Institute.
AREMA American Railway Engineering
and Maintenance of Way Association
ASTM American Society for Testing and
Materials.
ICEA Insulated Cable Engineers
Association (formerly IPCEA).
IEC International Electrotechnical Com-
mission
IEEE Institute of Electrical and
Electronics Engineers.
NEC National Electrical Code.
NEMA National Electrical
Manufacturers Association.
NFPA National Fire Protection
Association.
GOVERNMENT AGENCIES
OSHA Occupational Safety and Health
Act administered by U.S. Dept. of
Labor which establishes employee safety
standards in all industrial and commercial
establishments.
RUS Rural Utility Systems of the U.S. De-
partment of Agriculture, formerly REA.
FAA Federal Aviation Administration
EPA Environmental Protection Agency
DOE Department of Energy
FERC Federal Energy Regulatory
Commission
OKONITE REGISTERED TRADE
NAMES
C-L-X® Continuous-Lightweight-Exterior.
Welded and corrugated, impervious
metallic sheathed cables.
LOXARMOR® An interlocked “S” shaped
armor cable covering, normally galvanized
steel or aluminum.
OKOBON® A moisture resistant cable
finish consisting of an aluminum/
copolymer tape fused to itself and to an
overall jacket.
OKOBUS Fieldbus instrumentation cable.
OKOCLEAR TP® (TPPO) Thermoplastic
Polyolefin low smoke/zero halogen jacket
compound.
OKOCLEAR TS® Thermosetting Polyolefin low
smoke/zero halogen jacket compound.
OKOGUARD® Okonite's exclusive ethylene-pro-
pylene rubber (EPR) based, thermosetting
insulation, with an optimum balance of electrical
and physical properties unequaled in other solid
dielectrics, used on power cables rated 600 V
and above. (43rd Anniversary - 2011)
OKOLENE® Thermoplastic polyethylene or poly-
propylene based insulation or jacket
compound.
OKONITE® Okonite's exclusive ethylene
propylene rubber (EPR) based, thermo-
setting insulation used up to 2000V.
OKONITE-FMR® Okonite’s exclusive flame and
moisture resistant ethylene propylene rubber
(EPR) insulation used up to 2000V.
OKOGUARD-OKOLON® Composite insulation
system consisting of a layer of EPR and covered
with a chlorinated thermoset compound.
OKO-PACK® Okonite’s unique compact round
conductor shape and design.
OKOSEAL® A PVC insulation or jacketing com-
pound with excellent resistance to flame and
most chemicals.
OKOSEAL-N® PVC insulated and nylon
jacketed low voltage conductors, Type THHN,
THWN-2 and TFN.
OKOLON TP-CPE® Thermoplastic moisture re-
sistant CPE compound serving as an outer
jacket.
OKOLON TS-CPE® Thermoset moisture resis-
tant flame retardant CPE outer jacket.
OKOTHERM® Heat resistant silicone rubber
based insulation for use in high temperature lo-
cations.
OKOZEL® Okonite's name for its ETFE based
flame and radiation resistant
insulating and jacketing compound.
P-30® Okolene-Okoseal insulated 600V
multiple and single conductor control
cable.
P-45® Okolene-Okoseal Insulated 1000V
Multiple Conductor Control Cable.
X-OLENE® Okonite's name for its XLPE
insulation and jacket.
STANDARD TERMS
AWG American Wire Gauge, based on the cir-
cular mil system where 1 mil equals 0.001 inch.
CIC Cable in Conduit for buried distribution sys-
tems.
CIC Circuit Integrity flame retardant cables
C-L-X-M C-L-X Marine Shipboard Cable
CPE Chlorinated Polyethylene jacketing
material.
CSA Canadian Standards Association. An
independent organization which implements
and monitors the commercial and consumer
electrical product standards. The CSA as-
sures compliance to the various Canadian
Electrical Code requirements.
CT Designation given to cables meeting UL
requirements for cable tray use.
CTC Designation for Centralized Traffic
Control Code Line cable.
CWCMC UL’s designation for 600 volt
C-L-X marine shipboard cable - “continu-
ously welded corrugated MC” cable.
DEL Diesel Electric Locomotive and car
wiring with Okonite insulation and Okolon
jacket.
EPR Ethylene Propylene Rubber insulating
compound ingredient.
ER Exposed Run, UL term designating ca-
bles approved for open wire applications.
ETFE Modified Ethylene Tetrofluoroethylene
compound (Okozel) used for insulation and
jackets.
FIELDBUS CABLE - High Speed digital sig-
nal transmission instrumentation cable
having specific electrical characteristics.
FPL Power limited Fire Protective Signal
Cable (NEC Art. 760). 300V rated
FMR Flame and Moisture Retardant.
HL Designation given to MC and ITC cables
meeting NEC and UL requirements for use
in Division 1 hazardous locations.
INSULATION LEVEL-100% Cable for use
on grounded systems or where the system is
provided with relay protection such that
grounds faults will be cleared as rapidly as
possible but in any case within one minute.
INSULATION LEVEL-133% Cable for use
on ungrounded or grounded systems or
where the faulted section will be de-ener-
gized in a time not exceeding one hour.
ITC Instrumentation Tray Cable for instru-
mentation & control circuits operating �150V
and �5 amps., per NEC Article 727.
kcmil A unit of conductor area in thousands
of circular mils. (Formerly MCM).
LOCA Loss of Coolant Accident, IEEE 383
defines test requirements.
LCS Longitudinal Corrugated Shield.
GLOSSARY
MC Metal-Clad cable. NEC type designa-
tion for power and control cables enclosed
in a welded and corrugated metallic
sheath (C-L-X), or an interlocking tape ar-
mor (Loxarmor). (Article 330)
MC-HL Metal-Clad cable listed for hazard-
ous locations
mil 0.001 inch.
MV Medium Voltage cable. NEC designa-
tion for single & multiple conductor
insulated cable rated 2001 to 35,000 volts.
(NEC Article 328)
NPLF Non-Power Limited Fire Protective
Signal Cable (NEC Art. 760). 600V rated
OKO-MARINE UL designation for non-ar-
mored Marine Shipboard Cable.
PLTC Type designation for Power-
Limited Tray Cable for use in Class 2 or 3
power-limited circuits; instrumentation,
supervisory control, and thermocouple ex-
tension.
P-NS Single pair or triad, Non Shielded,
instrumentation or thermocouple extension
cable.
P-OS Single or multi Pairs or Triads with
Overall Shield, instrumentation or thermo-
couple extension cable.
POWER-LIMITED CIRCUIT Circuit either
inherently limited requiring no overcurrent
protection or limited by a combination of a
power source and overcurrent
protection.
PVC Polyvinyl Chloride insulating and
jacketing material which is usually flame
retardant and resistant to many
chemicals.
P-104 Okonite’s identification number is-
sued by the Pennsylvania Department of
Environmental Resources.
RHH NEC conductor type designation for
conductors with Heat resistant rubber or
XLPE insulation, for use in dry locations.
RHW-2 NEC conductor type designation
for conductors with Heat and Moisture re-
sistant rubber or XLPE insulation, for use
in 90°C wet or dry locations.
RTA Thermoplastic insulated, aluminum
shielded, polyethylene jacketed communi-
cation cable.
SCREEN A semiconducting nonmetallic
layer used under and over the insulation of
power cables rated over 2kV to reduce
electrical stresses and corona
SEMICONDUCTING An extruded layer or tape
of such resistance that when applied between
two elements of a cable the adjacent surfaces of
the two elements will maintain substantially the
same potential.
SHIELD A nonmagnetic, metallic material ap-
plied over an insulated conductor(s) to confine
the electric field to the insulation.
SP-OS Multiple Shielded Pairs or Triads with
Overall Shield, instrumentation or
thermocouple extension cable.
TC NEC type designation for power and
control tray cable. (Article 336)
TFN NEC conductor type designation for PVC
insulated nylon jacketed conductors in sizes #18
and 16 AWG for use in dry
locations.
THERMOCOUPLE CABLE - A cable consisting
of two dissimilar metals or alloys that, when elec-
trically joined at one end can be used to
measure temperature. These cables have no
voltage rating.
THHN NEC conductor type designation for PVC
insulated nylon jacketed conductors for use in
dry locations.
THWN-2 NEC conductor type designation for
PVC insulated nylon jacketed conductors for use
in 90°C wet or dry locations.
TPPO Thermoplastic Polyolefin, a thermoplastic
jacket material with low smoke characteristics
and is free of halogens.
UL Underwriters Laboratories. An independent
organization which examines, tests, lists and pe-
riodically inspects
equipment to appropriate standards.
URO-J Underground Residential distribution-
Okoguard (EPR) insulation-Okolene Jacket em-
ploying a concentric neutral.
USE Underground Service Entrance
cable. (NEC Article 338)
VERTICAL TRAY FLAME TEST
Conducted per UL, IEEE or ICEA procedures to
demonstrate that a single conductor (1/0 AWG
and larger) or multi-conductor cable will not
propagate a fire in the defined test.
VOLTAGE LEVELS
Power-Limited - 0-300 Volts
Low Voltage - 600-2000 Volts
Medium Voltage - 2400-46000 Volts
High Voltage - >46 to 345kV
VOLTAGE RATING kV, industry convention
to identify voltage levels, phase to phase
voltage.
VW-1 Basic flammability test for single
conductors; employs a tirrill burner applied
intermittently to a Vertical Wire.
XHHW-2 NEC conductor type designation
for conductors with Heat and Moisture resis-
tant thermoset insulation for use in 90°C wet
or dry locations.
XLPE Cross-Linked Polyethylene insulating
compound.
XLPO Cross Linked Polyolefin, a thermoset
jacket material with low smoke characteris-
tics and is free of halogens.
Z NEC conductor type designation for
conductors with ETFE insulation for use in
dry locations.
ZW NEC conductor type designation for
conductors with ETFE insulation for use in
wet or dry locations.
CONDUCTOR IDENTIFICATION
INFORMATION
E-1 Color sequences for utility conductor
identification, see Appendix E, Table E-1,
ICEA Standard S-73-532, includes green
and white.
E-2 Color sequence for industrial conductor
identification, see Appendix E, Table E-2,
ICEA Standard S-73-532, excludes green
and white.
METHOD-1 Conductor identification, colored
compounds with tracers in accordance with
the ICEA standard.
METHOD-2 Conductor identification, neutral
compounds with tracers in accordance with
the ICEA Standard.
METHOD-3 Conductor identification, neutral
or single colored compounds with surface
printing of numbers and color designations in
accordance with the ICEA Standard.
METHOD-4 Conductor identification, neutral
or single colored compounds with surface
printing of numbers in accordance with the
ICEA Standard.
METHOD-5 Conductor identification, individ-
ual color coding with braids in accordance
with the ICEA Standard.
GLOSSARY (continued)
InsulationOkoguard is Okonite's registered trade namefor its exclusive ethylene-propylene rubber(EPR) based, thermosetting compound,whose optimum balance of electrical andphysical properties is unequalled in othersolid dielectrics. Okoguard insulation, withthe distinctive red color and a totally inte-grated EPR system, provides the optimumbalance for long, problem free service.
JacketThe Okolon TS-CPE jacket on this cable is avulcanized chloronated polyethylene basedcompound which is mechanically rugged,flame, radiation and oil resistant.
ApplicationsOkoguard-Okolon TS-CPE 2 .4 kV cablesare heavy duty nonshielded cables designedfor use at up to 2.4 kV phase-to-phase in wetor dry locations in accordance with NECSection 310.10.Okoguard-Okolon TS-CPE nonshielded ca-bles are recommended for power distributionand motor circuits in generating plants andsubstations; in industrial and commercialbuildings.Single conductors may be installed in indus-trial or commercial occupancies in triplexedor random lay in any raceway or duct in wetor dry locations, or in open runs as permittedby NEC Article 396.Sizes 1/0 AWG and larger, may be installedin cable trays where permitted by NEC Sec-tion 392.10.
SpecificationsConductor: Annealed uncoated coppercompact stranded per ASTM B-496.
Strand Screen: Extruded semiconductingEPR strand screen. Meets or exceeds elec-trical and physical requirements of ICEAS-96-659/NEMA WC71 and UL 1072.
Insulation: Meets or exceeds electrical andphysical requirements of ICEA S-96-659/NEMA WC71 and UL 1072.
Jacket: Meets or exceeds electrical andphysical requirements of ICEA S-96-659/NEMA WC71 for chlorinated polyethyl-ene jackets.UL listed as Type MV-90, sunlight resistant,-40°C and for use in cable tray in accordance
with UL 1072. CSA listed as RW90 as5kV non-shielded (FT4 1/0 and larger)-40°C in accordance with CSA C22.2 No38.1/C non-shielded cables can surface dis-charge in service when in a randomphase spacing or when in contact withgrounded surfaces.
Product Features• Okoguard cables meet or exceed allrecognized industry standards (UL, CSA,NEMA/ICEA, IEEE).
• 90°C continuous operating temperature.
• 130°C emergency rating.• 250°C short circuit rating• Passes UL and IEEE 383 and 1202 (1/0and larger) Vertical Tray Flame Test.•Sizes 1/0 and larger meet CSA FT4 Ver-tical Tray Flame Test.•Sizes #1 and smaller meet CSA FT1.• Excellent corona resistance.
• Radiation resistant.
• Exceptional resistance to “treeing”.
• Stress cones not required.
• Moisture resistant.
• Resistant to most oils, acids, and alkalies.
• Sunlight Resistant.
• Sizes #6 and #8 AWG are identified asFAA-L-824, Type B 5kV rated.
COMPACT STRANDCONSTRUCTION
Okoguard®-Okolon® TS-CPE Type MV-902.4 kV Nonshielded Power CableOne Okopact® (Compact Stranded)Copper Conductor/90°C Rating Wet or DryFor Cable Tray Use-Sunlight Resistant
Product DataSection 2: Sheet 2
ULR
A
B
C
D
OK
ON
ITE
74/
0A
WG
CO
MP
AC
TC
UO
KO
GU
AR
DT
S-C
PE
2.4k
V
A Uncoated, Okopact (CompactStranded) Copper Conductor
B Strand Screen-ExtrudedSemiconducting EPR
C Insulation-Okoguard EPRD Jacket-Okolon TS-CPE
Okoguard-Okolon TS-CPE Type MV-902.4 kV Nonshielded Power CableOne Okopact (Compact Stranded)Copper Conductor/90°C Rating Wet or DryFor Cable Tray Use-Sunlight Resistant
*� 114-24-2213*� 114-24-2217� 114-24-2219� 114-24-2221
8642
8.413.321.233.6
125125125125
3.183.183.183.18
80808080
2.032.032.032.03
0.600.630.670.73
15.116.017.118.6
215260328427
250295368492
557597
130
6485
110145
––––
2222
114-24-2223� 114-24-2225� 114-24-2227
114-24-2229
11/02/03/0
42.453.567.485.0
125125125125
3.183.183.183.18
80808095
2.032.032.032.41
0.760.800.880.96
19.420.322.424.5
493580682838
558645742908
155180205240
170195220250
—195225260
212
212
212
3
� 114-24-2231114-24-2233
� 114-24-2237
4/0250350
107.0127.0177.0
125140140
3.183.563.56
95110110
2.412.792.79
0.971.081.18
24.627.429.9
99111981555
108612931660
280315385
290320385
300335410
3331
2
� 114-24-2243� 114-24-2249
114-24-2251
500750
1000
253.0380.0507.0
140155155
3.563.943.94
110125125
2.793.183.18
1.291.541.70
32.939.043.0
207530343891
220532244141
475600690
470585670
520675805
312
55
* Marked "FAA L-824 5kV Type B".
Visit Okonite's web site, www.okonite.com for the most up to date dimensions.
� Authorized stock item. Available from our Customer Service Center.
Aluminum Okopact Conductors
(1) Aluminum conductors are available on special order.
Ampacities
(2) Ampacities are in accordance with Table 310.60(C)(73) of theNEC for three single Type MV-90 conductors, or single conductors twisted to-gether (triplexed) and installed in an isolated conduit in air at an ambienttemperature of 40°C and a conductor temperature of 90°C.
(3) Ampacities are in accordance with Table 310.60(C)(77) of the NEC forthree single conductors or triplexed cable in one underground raceway, threefeet deep with a conductor temperature of 90°C, 100% Load Factor, an ambientearth temperature of 20°C, and thermal resistance (RHO) of 90.
(4) Ampacities based on single Type MV-90 conductors, or single conductorstwisted together (triplexed, quadruplexed, etc.), size 1/0 Awg and larger, in-stalled in uncovered cable tray in accordance with Section 392.80(B) of theNEC at an ambient temperature of 40°C and a conductor temperature rating of90°C.
In accordance with NEC Section 392.80(B)(2)(a), the ampacities are 75% of thevalues given in NEC Table 310.60(C)(69) (copper conductors). Where the cabletray is covered for more than six feet with solid unventilated covers, theampacities shall not exceed 93% of the values shown above.
Refer to the NEC, IEEE/ICEA-S-135 Power Cable Ampacities, or the OkoniteEngineering Data Bulletin for other ambient temperatures, circuit configurationsor installation requirements.
(5) Recommended size of rigid or nonmetallic conduit for three conductorsbased on 40% maximum fill .
*The jam ratio, conduit l.D. to cable O.D. should be checked to avoid possiblejamming.
K/15090202
Product DataSection 2: Sheet 2
Ramsey, New Jersey 07446THE OKONITE COMPANY
Conductor Size
-mm2
Catalo
gNum
ber(1
)
Conductor Size
AWG
or kcm
il
Jack
etThick
ness - m
m
Insu
latio
n
Thicknes
s - mm
Approx.
NetW
eight
lbs./
1000
’
Jack
etThick
ness - m
ils
Approx.
O.D. -
mm
Approx.
O.D. -
Inch
es
Conductor Size
Inch
es(5
)*
Approx.
ShipW
eight
lbs./
1000
’
Ampac
ities
(3)
Undergro
undDuct
Ampac
ities
(4)
Cable
Tray
Ampac
ities
(2)
Conduitin
Air
Insu
latio
n
Thicknes
s - mils
ULR
Okoguard is Okonite's registered tradename for its exclusive ethylene-propylenerubber (EPR) based, thermosetting com-pound, whose optimum balance ofelectrical and physical properties is un-equaled in other solid dielectrics.Okoguard insulation, with the distinctivered color and a totally integrated EPR sys-tem, provides the optimum balance ofelectrical and physical properties for long ,problem free service.The triple tandem extrusion of the screenswith the insulation provides optimum elec-trical characteristics.
The Okoseal (PVC) jacket supplied withthis cable is mechanically rugged and hasexcellent resistance to oil, acids and mostchemicals.
Okoguard shielded Okoseal Type MV-105power cables are recommended for useas feeder circuits, in electric utility generat-ing stations, for distribution circuits, andfor feeders or branch circuits in industrialand commercial installations.Type MV cables may be installed in wet ordry locations, indoors or outdoors (ex-posed to sunlight), in any raceway orunderground duct, directly buried if in-stalled in a system with a groundingconductor in close proximity that conformswith NEC Section 250.4(A)(5), or messen-ger supported in industrial establishmentsand electric utilities. Sizes 1/0 AWG andlarger may also be installed in cable tray.
Annealed uncoated coppercompact stranded per ASTM B-496.
Extruded semiconductingEPR strand screen. Meets or exceedselectrical and physical requirements ofICEA S-93-639/NEMA WC74 & S-97-682,AEIC CS8, CSA C68.3 and UL 1072.
Meets or exceeds electricaland physical requirements of ICEA S-93-639/NEMA WC74 & S-97-682, AEIC CS8,CSA C68.3 and UL 1072.
Extruded semicon-ducting EPR insulation screen applieddirectly over the insulation. Meets orexceeds electrical and physical re-quirements of ICEA S-93-639/NEMAWC74 & S-97-682, AEIC CS8, CSAC68.3 and UL 1072.
5 mil bare copper tape helicallyapplied with 25% minimum overlap.
Meets or exceeds electrical andphysical requirements of ICEA S-93-639/NEMA WC74 & S-97-682, CSAC68.3 and UL 1072 for polyvinyl chlo-ride jackets.UL Listed as Type MV-105 and sun-light resistant, in accordance with UL1072.CSA C68.3 listed and rated FT4.
• Triple tandem extruded, all EPRsystem.
• Okoguard cables meet or exceed allrecognized industry standards (UL,AEIC, NEMA/ICEA, IEEE).
• 105°C continuous operating temp-erature.
• 140°C emergency rating.
• 250°C short circuit rating.
• Passes UL and IEEE 383 and 1202(1/0 AWG and larger) Vertical TrayFlame Test.
• Excellent corona resistance.
• Screens are clean stripping.
• Exceptional resistance to “treeing”.
• Exceptional resistance to moisture.
• Resistant to most oils, acids, andalkalies.
• Sunlight resistant.
• For Cable Tray Use.
• CSA FT4.
• CSA � 350: LTDD (-25C)
• CSA � 500: LTGG (-40C)
• Improved Temperature Rating.
COMPACT STRAND
CONSTRUCTION
Okoguard®-Okoseal® Type MV-105
One Okopact® (Compact Stranded) Copper Conductor/105°C Rating5kV-133% or 8kV-100% Insulation Level
ULR
Uncoated, Okopact (CompactStranded) Copper ConductorStrand Screen-Extruded Semicon-ducting EPRInsulation-Okoguard EPRInsulation Screen-Extruded Semi-conducting EPRShielding-CopperTapeJacket-Okoseal
Okoguard-Okoseal Type MV-105One Okopact (Compact Stranded)Copper Conductor/ 105°C Rating5kV-133% or 8kV-100% Insulation Level
� 114-23-3824� 114-23-3826
114-23-3865� 114-23-3832
1/02/03/04/0
53.567.485.0
107.0
0.610.650.700.75
0.670.710.760.81
60608080
1.521.522.032.03
0.810.850.950.99
20.621.624.125.2
615720895
1030
655775950
1090
200225270305
210235270310
220245290335
212
212
33
� 114-23-3834� 114-23-3838� 114-23-3846� 114-23-3873
114-23-3855
250350500750
1000
127.0177.0253.0380.0507.0
0.800.891.011.191.34
0.860.951.071.261.40
8080808080
2.032.032.032.032.03
1.051.141.261.451.59
26.729.032.036.940.4
11851540205529403781
12501625215531203960
355430530665770
345415505630720
370460580750900
331
2
312
44
Visit www.okonite.com for the most current cable data.
� Available from our Customer Service Center.
(1) Aluminum conductors are available on special order.
(2) Ampacities are in accordance with Table 310.60(C)(73) of the NEC for threesingle Type MV-105 5kV conductors or single conductors twisted together(triplexed) and installed in an isolated conduit in air at an ambient temperatureof 40°C and a conductor temperature of 105°C. Refer to Table 310.60(C)(73)for 8kV ampacities
(3) Ampacities are in accordance with Table 310.60(C)(77) of the NEC for threesingle 5kV conductors or triplexed cable in one underground raceway, threefeet deep with a conductor temperature of 105°C, 100% Load Factor, an ambi-ent earth temperature of 20°C and thermal resistance (RHO) of 90. Refer to Table310.60(C)(77) for 8kV ampacities.
(4) Ampacities based on single Type MV-105 5kV conductors, or single conduc-tors twisted together (triplexed, quadruplexed, etc.) size 1/0 AWG and larger,installed in uncovered cable tray in accordance with Section 392.80(B) of theNEC at an ambient temperature of 40°C and a conductor temperature rating of105°C. In accordance with NEC Section 392.80(B)(2)(a) the ampacities are75% of the values given in NEC Table 310.60(C)(69) (copper conductors).Where the cable tray is covered for more than six feet with solid unventilatedcovers, the ampacities shall not exceed 93% of the values shown above. Referto Table 310.60(C)(69) for 8kV ampacities.
Refer to the NEC, IEEE/ICEA S-135 Power Cable Ampacities, or the OkoniteEngineering Data Bulletin for installation in duct banks, multiple point groundedshields, other ambient temperatures, circuit configurations or installation re-quirements.
(5) Recommended size of rigid or nonmetallic conduit for three conductorsbased on 40% maximum fill.
*The jam ratio, conduit l.D. to cable O.D. should be checked to avoid possiblejamming.
F/14100203
ULR
THE OKONITE COMPANYRamsey, New Jersey 07446
Okoguard is Okonite's registered trade namefor its exclusive ethylene-propylene rubber(EPR) based, thermosetting compound,whose optimum balance of electrical andphysical properties is unequaled in othersolid dielectrics. Okoguard insulation, withthe distinctive red color and a totally inte-grated EPR system, provides the optimumbalance of electrical and physical propertiesfor long , problem free service.The triple tandem extrusion of the screenswith the insulation provides optimum electri-cal characteristics.
The Okoseal (PVC) jacket supplied with thiscable is mechanically rugged and has excel-lent resistance to oil, acids and mostchemicals.
Okoguard shielded Okoseal Type MV-105power cables are recommended for distribu-tion circuits, and for feeders or branchcircuits.Type MV cables may be installed in wet ordry locations, indoors or outdoors (exposedto sunlight), in any raceway or undergroundduct, directly buried if installed in a systemwith a grounding conductor in close proximitythat conforms with NEC Section 250.4(A)(5),or messenger supported in industrial estab-lishments and electric utilities.
Annealed uncoated coppercompact stranded per ASTM B-496.
Extruded semiconductingEPR strand screen. Meets or exceeds elec-trical and physical requirements of ICEAS-93-639/NEMA WC74 & S-97-682, AEICCS8 and UL 1072.
Meets or exceeds electrical andphysical requirements of ICEA S-93-639/NEMA WC74 & S-97-682, AEIC CS8and UL 1072.
Extruded semiconduct-ing EPR insulation screen applied directlyover the insulation. Meets or exceeds electri-cal and physical requirements of ICEAS-93-639/NEMA WC74 & S-97-682, AEICCS8 and UL 1072.
5 mil bare copper tape helically ap-plied with 12.5% nominal overlap.
Meets or exceeds electrical andphysical requirements of ICEA S-93-639/NEMA WC74 & S-97-682, and UL1072 for polyvinyl chloride jackets.UL Listed as Type MV-105 and sunlightresistant, in accordance with UL 1072.Cables listed to CSA C68.3 are alsoavailable.
• Triple tandem extruded, all EPR system.
• Okoguard cables meet or exceed allrecognized industry standards (UL, AEIC,NEMA/ICEA, IEEE).
• 105°C continuous operating temperature.
• 140°C emergency rating.
• 250°C short circuit rating.
• Excellent corona resistance.
• Screens are clean stripping.
• Exceptional resistance to “treeing”.
• Exceptional resistance to moisture.
• Resistant to most oils, acids, and alkalies.
• Sunlight resistant.
• Improved Temperature Rating.
COMPACT STRAND
CONSTRUCTION
Okoguard®-Okoseal® Type MV-105
One Okopact® (Compact Stranded) Copper Conductor/105°C Rating5kV-133% or 8kV-100% Insulation Level
Uncoated, Okopact (CompactStranded) Copper ConductorStrand Screen-Extruded Semicon-ducting EPRInsulation-Okoguard EPRInsulation Screen-Extruded Semi-conducting EPRShielding-CopperTapeJacket-Okoseal
ULR
Okoguard-Okoseal Type MV-105One Okopact (Compact Stranded)Copper Conductor/ 105°C Rating5kV-133% or 8kV-100% Insulation Level
� 114-23-3817� 114-23-3819� 114-23-3821
642
13.321.233.6
0.440.480.54
0.500.540.60
606060
1.521.521.52
0.640.690.74
16.317.518.8
285355455
320385495
84110145
92120155
222
114-23-3823� 114-23-3825� 114-23-3827
114-23-3829
11/02/03/0
42.453.567.485.0
0.580.610.650.70
0.630.670.710.75
60606080
1.521.521.522.03
0.770.810.850.93
19.520.612.623.6
530610710880
570645765935
175200225270
180210235270
212
212
212
3
� 114-23-3831� 114-23-3833� 114-23-3837
4/0250350
107.0127.0177.0
0.750.800.89
0.810.860.95
808080
2.032.032.03
0.991.041.14
25.126.429.0
103511801535
110012451625
305355430
310345415
33
312
� 114-23-3843� 114-23-3849
114-23-3851
500750
1000
253.0380.0507.0
1.011.191.33
1.071.251.39
808080
2.032.032.03
1.251.431.57
31.836.839.9
205029353650
215031103825
530665770
505630720
312
45
Visit www.okonite.com for the most current cable data.
� Available from our Customer Service Center.
for non-stock items is 5000’.
(1) Aluminum conductors are available on special order.
(2) Ampacities are in accordance with Table 310.60(C)(73) of the NEC for threesingle Type MV-105 5kV conductors or single conductors twisted together(triplexed) and installed in an isolated conduit in air at an ambient temperatureof 40°C and a conductor temperature of 105°C. Refer to Table 310.60(C)(73)for 8kV ampacities
(3) Ampacities are in accordance with Table 310.60(C)(77) of the NEC for threesingle 5kV conductors or triplexed cable in one underground raceway, threefeet deep with a conductor temperature of 105°C, 100% Load Factor, an ambi-ent earth temperature of 20°C and thermal resistance (RHO) of 90. Refer to Table310.60(C)(77) for 8kV ampacities.
Refer to the NEC, IEEE/ICEA S-135 Power Cable Ampacities, or the OkoniteEngineering Data Bulletin for installation in duct banks, multiple point groundedshields, other ambient temperatures, circuit configurations or installation re-quirements.
(4) Recommended size of rigid or nonmetallic conduit for three conductorsbased on 40% maximum fill.
*The jam ratio, conduit l.D. to cable O.D. should be checked to avoid possiblejamming.
K/15020204
ULR
THE OKONITE COMPANYRamsey, New Jersey 07446
Okoguard is Okonite's registered trade namefor its exclusive ethylene-propylene rubber(EPR) based, thermosetting compound,whose optimum balance of electrical andphysical properties is unequaled in othersolid dielectrics. Okoguard insulation, withthe distinctive red color and a totally inte-grated EPR system, provides the optimumbalance of electrical and physical propertiesfor long, problem free service.The triple tandem extrusion of the screenswith the insulation provides optimum electri-cal characteristics.
The Okoseal (PVC) jacket supplied with thiscable is mechanically rugged and has excel-lent resistance to flame, oil, acids and mostchemicals.
Okoguard shielded Okoseal Type MV-105power cables are recommended for use asfeeder circuits, in electric utility generatingstations, for distribution circuits, and for feed-ers or branch circuits in industrial andcommercial installations.Type MV cables may be installed in wet ordry locations, indoors or outdoors (exposedto sunlight), in any raceway or under-ground duct, directly buried if installed in asystem with a grounding conductor in closeproximity that conforms with NEC Section250.4(A)(5), or messenger supported in in-dustrial establishments and electricutilities. Sizes 1/0 AWG and larger mayalso be installed in cable tray.
Annealed uncoated coppercompact stranded per ASTM B-496.
Extruded EPR semiconduct-ing strand screen. Meets or exceedselectrical and physical requirements of ICEAS-93-639/NEMA WC74 & S-97-682, AEICCS8, CSA C68.3 and UL 1072.
Meets or exceeds electrical andphysical requirements of ICEAS-93-639/NEMA WC74 & S-97-682, AEICCS8, CSA C68.3 and UL 1072.
Extruded EPR semicon-ducting insulation screen applied directlyover the insulation. Meets or exceeds electricaland physical requirements of ICEA
S-93-639/NEMA WC74 & S-97-682,AEIC CS8, CSA C68.3 and UL 1072.
5 mil bare copper tape helicallyapplied with 25% minimum overlap.
Meets or exceeds electrical andphysical requirements of ICEAS-93-639/NEMA WC74 & S-97-682, CSAC68.3 and UL 1072 for polyvinyl chloridejackets.UL listed as Type MV-105, sunlight resis-tant and for use in cable tray inaccordance with UL 1072.CSA C68.3 listed and rated FT4.
• Triple tandem extruded, all EPR system.• Okoguard cables meet or exceed allrecognized industry standards (UL, CSA,AEIC, NEMA/ICEA, IEEE).• 105°C continuous operating temperature.
• 140°C emergency rating.
• 250°C short circuit rating.
• Passes the Vertical Tray Flame Testrequirements of UL 1072 and IEEE 383and 1202.
• Excellent corona resistance.
• Screens are clean stripping.
• Exceptional resistance to “treeing”.
• Exceptional resistance to moisture.
• Resistant to most oils, acids, and alkalies.
• Sunlight resistant.
• For Cable Tray Use.
• CSA FT4.
• CSA � 350: LTDD (-25C)
• CSA � 500: LTGG (-40C)
• Improved Temperature Rating.
COMPACT STRAND
CONSTRUCTION
Okoguard®-Okoseal® Type MV-105
One Okopact® (Compact Stranded) Copper Conductor/105°C Rating100% and 133% Insulation Level
Uncoated, Okopact (CompactStranded) Copper ConductorStrand Screen-ExtrudedSemiconducting EPRInsulation-Okoguard EPRInsulation Screen-ExtrudedSemiconducting EPRShield- Copper TapeJacket-Okoseal
ULR
Okoguard-Okoseal Type MV-105One Okopact (Compact Stranded)Copper Conductor/105°C Rating100% and 133% Insulation Level
115-23-3064115-23-3066115-23-3067
1/02/03/0
53.567.485.0
0.740.780.83
0.800.840.89
808080
2.032.032.03
0.981.021.07
24.825.827.1
760870
1005
825935
1070
215255290
215245275
220250290
333
115-23-3069115-23-3074115-23-3076
4/0250350
107.0127.0177.0
0.880.931.03
0.940.981.07
808080
2.032.032.03
1.121.171.26
28.429.732.0
116013301700
124014151800
330365440
315345415
335370460
331
2
312
115-23-3090115-23-3091115-23-3092
500750
1000
253.0380.0507.0
1.141.321.47
1.191.371.52
808080
2.032.032.03
1.381.551.71
35.139.443.4
223031053960
227533404215
535655755
500610690
575745890
455
� 115-23-3230� 115-23-3232
115-23-3234
1/02/03/0
53.567.485.0
0.830.870.92
0.880.920.98
808080
2.032.032.03
1.101.111.16
28.028.229.4
905970
1100
97510301185
215255290
215245275
220250290
3331
2
� 115-23-3236� 115-23-3238� 115-23-3240
4/0250350
107.0127.0177.0
0.961.011.11
1.021.071.17
808080
2.032.032.03
1.211.261.35
30.732.034.3
128014351810
137015201940
330365440
315345415
335370460
312
312
4
� 115-23-3242� 115-23-3243� 115-23-3244
500750
1000
253.0380.0507.0
1.221.401.55
1.281.461.60
8080
110
2.032.032.79
1.471.651.86
37.341.947.1
235032404220
253534804490
535655755
500610690
575745890
456
Visit Okonite's web site, www.okonite.com for the most up to date dimensions.
� Available from our Customer Service Centers.Minimum Manufacturing Quantity for non-stock items is 5000'.
(1) Aluminum conductors are available on special order. To order aluminumconductors, change the first three digits of the catalog number from 115 to 135.
(2) Ampacities are in accordance with Table 310.60(C)(73)of the NEC for threesingle Type MV-105 conductors, or single conductors twisted together(triplexed) and installed in an isolated conduit in air at an ambient temperatureof 40°C and a conductor temperature of 105°C.
(3) Ampacities are in accordance with Table 310.60(C)(77)of the NEC for threesingle conductors or triplexed cable in one underground raceway, three feetdeep with a conductor temperature of 105°C, 100% Load Factor, an ambientearth temperature of 20°C, and thermal resistance (RHO) of 90.
Refer to the NEC, IEEE/ICEA S-135 Power Cable Ampacities, or the OkoniteEngineering Data Bulletin EHB for installation in duct banks, multiple point
ground shields, other ambient temperatures, circuit configurations or installationrequirements.
(4) Ampacities based on single Type MV-105 conductors, or single conductorstwisted together (triplexed, quadruplexed, etc.) size 1/0 AWG and larger, in-stalled in uncovered cable tray in accordance with Section 392.80(B) of theNEC at an ambient temperature of 40°C and a conductor temperate rating of105°C. In accordance with NEC Section 392.80(B)(2)(a) (copper conductors),the values are 75% of the values given in table 310.69. Where the cable tray iscovered for more than six feet with solid unventilated covers, the ampacitiesshall not exceed 93% of the values shown above.
(5) Recommended size of rigid or nonmetallic conduit for three conductorsbased on 40% maximum fill.
*The jam ratio, conduit I.D. to cable O.D. should be checked to avoid possiblejamming.
L/14100208
ULR
THE OKONITE COMPANYRamsey, New Jersey 07446
Okoguard is Okonite’s registered trade namefor its exclusive ethylene-propylene rubber(EPR) based, thermosetting compound,whose optimum balance of electrical andphysical properties is unequaled in othersolid dielectrics. Okoguard insulation, withthe distinctive red color and a totally inte-grated EPR system, provides the optimumbalance of electrical and physical propertiesfor long, problem free service.The triple tandem extrusion of the screenswith the insulation provides optimum electri-cal characteristics.
The Okoseal (PVC) jacket supplied with thiscable is mechanically rugged and has excel-lent resistance to oil, acids and mostchemicals.
Okoguard shielded Okoseal Type MV-105power cables are recommended for distribu-tion circuits, and for feeders or branchcircuits.Type MV cables may be installed in wet ordry locations, indoors or outdoors (exposedto sunlight), in any raceway or undergroundduct, directly buried if installed in a systemwith a grounding conductor in close proximitythat conforms with NEC Section 250.4(A)(5),or messenger supported in industrial estab-lishments and electric utilities.
Annealed uncoated coppercompact stranded per ASTM B-496.
Extruded semiconductingEPR strand screen. Meets or exceedselectrical and physical requirements ofICEA S-93-639/NEMA WC74, AEIC CS8and UL 1072.
Meets or exceeds electrical andphysical requirements of ICEA S-93-639/NEMA WC74 & S-97-682, AEIC CS8and UL 1072.
Extruded semiconduct-ing EPR insulation screen . Meets orexceeds electrical and physical requirementsof ICEA S-93-639/NEMA WC74 & S-97-682,AEIC CS8 and UL 1072.
5 mil bare copper tape helically ap-plied with 12.5% nominal overlap.
Meets or exceeds electricaland physical requirements of ICEA S-93-639/NEMA WC74 & S-97-682 andUL 1072 for polyvinyl chloride jackets.UL Listed as Type MV-105 and sunlightresistant in accordance with UL 1072 .Cables listed to CSA C68.3 are alsoavailable.
• Triple tandem extruded, all EPR system.
• Okoguard cables meet or exceed allrecognized industry standards (UL,AEIC, NEMA/ICEA, IEEE).
• 105°C continuous operating temperature.
• 140°C emergency rating.
• 250°C short circuit rating.
• Excellent corona resistance.
• Screens are clean stripping.
• Exceptional resistance to “treeing”.
• Moisture resistant.
• Resistant to most oils, acids, and alkalies.
• Sunlight resistant.
• Improved Temperature Rating.
COMPACT STRAND
CONSTRUCTION
Okoguard®-Okoseal® Type MV-105
One Okopact® (Compact Stranded) Copper Conductor/105°C Rating100% and 133% Insulation Level
Uncoated, Okopact (CompactStranded) Copper ConductorStrand Screen- ExtrudedSemiconducting EPRInsulation-Okoguard EPRInsulation Screen- Extruded semi-conducting EPRShield-Copper TapeJacket Okoseal
ULR
Okoguard-Okoseal Type MV-105One Okopact (Compact Stranded)Copper Conductor/105°C Rating
115-23-3011115-23-3013
21
33.642.4
0.670.70
0.730.76
6080
1.522.03
0.870.94
22.123.9
555665
610720
165190
225260
165185
33
115-23-3015115-23-3017115-23-3019
1/02/03/0
53.567.485.0
0.740.780.83
0.800.840.89
808080
2.032.032.03
0.981.021.07
24.825.827.2
755865
1000
820930
1070
215255290
295335380
215245275
333
115-23-3021115-23-3023115-23-3027
4/0250350
107.0127.0177.0
0.880.931.03
0.940.991.07
808080
2.032.032.03
1.121.181.26
28.330.032.0
117013251700
125014051800
330365440
435475575
315345415
331
2
312
115-23-3031115-23-3035115-23-3037
500750
1000
253.0380.0507.0
1.141.321.47
1.191.371.52
808080
2.032.032.03
1.381.551.71
35.139.443.4
224031053950
238533404185
535655755
700865
1005
500610690
455
� 115-23-3111115-23-3113
21
33.642.4
0.760.79
0.810.85
8080
2.032.03
1.001.04
25.426.4
670755
720820
165190
225260
165185
33
� 115-23-3115� 115-23-3117
115-23-3119
1/02/03/0
53.567.485.0
0.830.870.92
0.890.920.98
808080
2.032.032.03
1.071.111.16
27.128.229.3
845950
1100
91510201180
215255290
295335380
215245275
3331
2
� 115-23-3121� 115-23-3123� 115-23-3127
4/0250350
107.0127.0177.0
0.961.011.11
1.021.071.16
808080
2.032.032.03
1.201.261.35
30.532.034.3
126014151790
136015001920
330365440
435475575
315345415
312
312
4
� 115-23-3131� 115-23-3135� 115-23-3139
500750
1000
253.0380.0507.0
1.221.401.54
1.281.461.60
8080
110
2.032.032.79
1.471.641.84
37.341.746.7
232532204075
251034554340
535655755
700865
1005
500610690
456
Visit Okonite's web site, www.okonite.com for the most up to date dimensions.
� Available from our Customer Service Centers.
(1) Aluminum conductors are available on special order.
(2) Ampacities are in accordance with Table 310.60(C)(73) of the NEC for threesingle Type MV-105 conductors, or single conductors twisted together (tri-plexed) and installed in an isolated conduit in air at an ambient temperature of40°C and a conductor temperature of 105°C.
(3) Ampacities are in accordance with Table 310.60(C)(81) of the NEC for aninsulated single conductor directly buried with a conductor temperature rating of105°C, ambient earth temperature of 20°C, 100% Load Factor, thermal resis-tance (RHO) of 90, 7 1/2 inch spacing between conductor center lines, and 24inch spacing between circuits.
(4)Ampacities are in accordance with Table 310.60(C)(77) of the NEC for threesingle conductors or triplexed cable in one underground raceway, three feet
deep with a conductor temperature of 105°C, 100% Load Factor, an ambientearth temperature of 20°C, and thermal resistance (RHO) of 90.
Refer to the NEC, IEEE/ICEA S-135 Power Cable Ampacities, or the OkoniteEngineering Data Bulletin for installation in duct banks, multiple point groundedshields, other ambient temperatures, circuit configurations or installation re-quirements.
(5) Recommended size of rigid or nonmetallic conduit for three conductorsbased on 40% maximum fill.
*The jam ratio, conduit l.D. to cable O.D. should be checked to avoid possiblejamming.
J/15010209
ULR
THE OKONITE COMPANYRamsey, New Jersey 07446
Okoguard is Okonite's registered trade namefor its exclusive ethylene-propylene (EPR)based, thermosetting compound, whose opti-mum balance of electrical and physicalproperties is unequaled in other solid dielec-trics. Okoguard insulation, with the distinctivered color and a totally integrated EPR sys-tem, provides the optimum balance ofelectrical and physical properties for long,problem free service.The triple tandem extrusion of the screenswith the insulation provides optimum electri-cal characteristics.
The Okolon TS-CPE jacket on this cable is avulcanized chloronated polyethylene basecompound which is mechanically rugged,flame, radiation, and oil resistant.
Okoguard shielded Okolon TS-CPE TypeMV-105 power cables are recommended foruse as feeder circuits in electric utility gener-ating stations, for distribution circuits, and forfeeders or branch circuits in industrial andcommercial installations. Type MV cablesmay be installed in wet or dry locations, in-doors or outdoors (exposed to sunlight), inany raceway or underground duct, directlyburied if installed in a system with a ground-ing conductor in close proximity thatconforms with NEC Section 250.4(A)(5), ormessenger supported in industrial establish-ments and electric utilities. Sizes 1/0 AWGand larger may also be installed in cabletray.
Annealed uncoated coppercompact stranded per ASTM B-496.
Extruded semiconductingEPR strand screen. Meets or exceeds elec-trical and physical requirements of ICEAS-93-639/NEMA WC74 & S-97-682, AEICCS8, CSA C68.3 and UL 1072.
Meets or exceeds electrical andphysical requirements of ICEAS-93-639/NEMA WC74 & S-97-682, AEICCS8, CSA C68.3 and UL 1072.
Extruded semiconduct-ing EPR insulation screen. Meets or exceeds
electrical and physical requirements ofICEA S-93-639/NEMA WC74 & S-97-682,AEIC CS8, CSA C68.3 and UL 1072.
5 mil bare copper tape helically ap-plied, with 25% minimum overlap.
Meets or exceeds electrical andphysical requirements of ICEAS-93-639/NEMA WC74 & S-97-682, CSAC68.3 and UL 1072 for chlonated polyethyl-ene jackets.UL listed as Type MV-105, sunlight resis-tant and for use in cable tray in accordancewith UL 1072.CSA listed meeting the requirements ofC68.3 and rated FT4 (1/0 AWG and larger)and -40°C.
• Triple tandem extruded, all EPR system.• Okoguard cables meet or exceed all rec-ognized industry standards (UL, CSA,AEIC, NEMA/ICEA, IEEE).• 105°C continuous operating temperature.• 140°C emergency rating.• 250°C short circuit rating.• Passes UL and IEEE 383 and 1202 (1/0AWG & larger) Vertical Tray Flame Tests.• Excellent corona resistance.• Screens are clean stripping.• Exceptional resistance to “treeing.”• Moisture resistant.• Resistant to most oils, acids, andalkalies.
• Sunlight resistant.
• For Cable Tray Use; 1/0 AWG and larger.
• CSA FT4 and -40°C.
• Improved Temperature Rating.
COMPACT STRAND
CONSTRUCTION
Okoguard®-Okolon® TS-CPE Type MV-105
One Okopact® (Compact Stranded) Copper Conductor/105°C Rating100% and 133% Insulation Level
Uncoated, Okopact (CompactStranded) Copper ConductorStrand Screen-Extruded Semicon-ducting EPRInsulation-Okoguard EPRInsulation Screen-Extruded Semiconducting EPRShield Copper TapeJacket-Okolon TS-CPE
ULR
Okoguard-Okolon TS-CPE Type MV-105One Okopact (Compact Stranded)Copper Conductor/ 105°C Rating100% and 133% Insulation Level
115-23-2011115-23-2013
21
33.642.4
0.670.70
0.730.76
6080
1.522.03
0.890.96
22.524.4
585700
640765
165190
165185
——
33
115-23-2015115-23-2017115-23-2019
1/02/03/0
53.567.485.0
0.730.770.82
0.790.830.88
808080
2.032.032.03
1.001.041.09
25.326.427.6
790905
1040
855965
1110
215255290
215245275
220250290
333
115-23-2021115-23-2023115-23-2027
4/0250350
107.0127.0177.0
0.870.931.01
0.930.991.07
808080
2.032.032.03
1.131.191.28
28.730.332.4
120013701725
128014501825
330365440
315345415
335370460
312
312
4
115-23-2031115-23-2035115-23-2038
500750
1000
253.0380.0507.0
1.131.311.46
1.191.371.52
808080
2.032.032.03
1.391.571.73
35.439.943.9
225531404020
237033204255
535655755
500610690
575745890
455
115-23-2111115-23-2113
21
33.642.4
0.750.79
0.810.85
8080
2.032.03
1.011.05
25.826.7
710790
775860
165190
165185
——
33
115-23-2115115-23-2117115-23-2119
1/02/03/0
53.567.485.0
0.820.860.91
0.880.920.97
808080
2.032.032.03
1.081.121.18
27.528.529.9
880995
1145
94510751225
215255290
215245275
220250290
312
312
312
115-23-2121115-23-2123115-23-2127
4/0250350
107.0127.0177.0
0.961.011.10
1.021.071.16
808080
2.032.032.03
1.221.281.37
31.132.434.7
131014651840
140015651940
330365440
315345415
335370460
312
44
� 115-23-2131� 115-23-2135
115-23-2138
500750
1000
253.0380.0507.0
1.221.401.54
1.281.461.60
8080
110
2.032.032.79
1.491.661.87
37.742.247.5
238532854275
257035404540
535655755
500610690
575745890
556
115-23-2144115-23-2145
12501500
633.5760.2
1.751.88
1.811.94
110110
4.334.33
2.082.20
52.756.0
52556140
56456540
845925
770845
9951090
68
Visit Okonite's web site, www.okonite.com for the most up to date dimensions.
� . Available from our Customer Service Centers.
(1) Aluminum conductors are available on special order.
(2) Ampacities are in accordance with Table 310.60(C)(73) of the NEC for threesingle Type MV-105 conductors, or single conductors twisted together (tri-plexed) and installed in an isolated conduit in air at an ambient temperature of40°C and a conductor temperature of 105°C.
(3) Ampacities are in accordance with Table 310.60(C)(77) of the NEC for threesingle conductors or triplexed cable in one underground raceway, three feetdeep with a conductor temperature of 105°C, 100% Load Factor, an ambientearth temperature of 20°C and thermal resistance (RHO) of 90.
(4) Ampacities based on single Type MV-105 conductors, or single conductorstwisted together (triplexed, quadruplexed, etc.), size1/0 AWG and larger, in-stalled in uncovered cable tray in accordance with Section 392.80(B) of theNEC at an ambient temperature of 40°C and a conductor temperature rating of
105°C. In accordance with NEC Section 392.80(B)(2)(a), the ampacities are75% of the values given in NEC Table 310.60(C)(69) (copper conductors).Where the cable tray is covered for more than six feet with solid unventilatedcovers, the ampacities shall not exceed 93% of the values shown above.
Refer to the NEC, IEEE/ICEA-S-135 Power Cable Ampacities, or the OkoniteEngineering Data Bulletin for installation in duct banks, multiple point groundedshields, other ambient temperatures, circuit configurations or installation re-quirements.
(5) Recommended size of rigid or nonmetallic conduit for three conductorsbased on 40% maximum fill.
*The jam ratio conduit l.D. to cable O.D. should be checked to avoid possiblejamming.
J/12100211
ULR
THE OKONITE COMPANYRamsey, New Jersey 07446
Okoguard Okonite's registered trade namefor its exclusive ethylene-propylene rubber(EPR) based, thermosetting compound,whose optimum balance of electrical andphysical properties is unequaled in othersolid dielectrics. Okoguard insulation, withthe distinctive red color and a totally inte-grated EPR system, provides the optimumbalance of electrical and physical propertiesfor long, problem free service. The triple tan-dem extrusion of the screens with theinsulation provides optimum electrical char-acteristics.
The Okoseal (PVC) jacket supplied with thiscable is mechanically rugged and has excel-lent resistance to oil and most chemicals.
Okoguard shielded Okoseal Type MV-105power cables are recommended for distribu-tion circuits, and for feeders or branchcircuits in industrial and commercial installa-tions.Type MV cables may be installed in wet ordry locations, indoors or outdoors (exposedto sunlight), in any raceway or undergroundduct, directly buried if installed in a systemwith a grounding conductor in close proximitythat conforms with NEC Section 250.4(A)(5),or messenger supported in industrial estab-lishments and electric utilities.
Annealed uncoated coppercompact stranded per ASTM B-496.
Extruded semiconductingEPR strand screen. Meets or exceeds elec-trical and physical requirements of ICEAS-93-639/NEMA WC7 & S-97-682, AEICCS8 and UL 1072.
Meets or exceeds electrical andphysical requirements of ICEA S-93-639/NEMA WC74, & S-97-682 AEIC CS8and UL 1072.
Extruded semiconduct-ing EPR insulation screen. Meets or exceedselectrical and physical requirements of ICEAS-93-639/NEMA WC74 & S-97-682, AEICCS8 and UL 1072.
5 mil bare copper tape helically ap-plied with 12.5% nominal overlap.
Meets or exceeds electrical andphysical requirements of ICEA S-93-639/NEMA WC74 & S-97-682 and UL 1072for polyvinyl chloride jackets.UL Listed as Type MV-105 and sunlight re-sistant, in accordance with UL 1072.A flame retardant construction, size 1/0AWG and larger, for installation in cable trayis available on special order. This construc-tion is UL labeled “MV-105 FOR CT USE.”Cables listed to CSA C68.3 and rated FT4and -25°C are available on special orders.
• Triple tandem extruded all EPR system.• Okoguard cables meet or exceed all rec-ognized industry standards (UL, AEIC,NEMA/ICEA, IEEE).• 105°C continuous operating temperature.• 140°C emergency rating.• 250°C short circuit rating.• Excellent corona resistance.• Screens are clean stripping.• Exceptional resistance to “treeing.”• Moisture resistant.• Resistant to most oils, acids, and alkalies.• Sunlight resistant.• Improved Temperature Rating
COMPACT STRAND
CONSTRUCTION
Okoguard®-Okoseal® Type MV-105
One Okopact® (Compact Stranded) Copper Conductor/105°C Rating100% and 133% Insulation Level
Uncoated, Okopact (CompactStranded) Copper ConductorStrand Screen- ExtrudedSemiconducting EPRInsulation-Okoguard EPRInsulation Screen -ExtrudedSemiconducting EPRShield-Copper TapeJacket-Okoseal
ULR
� 115-23-3516115-23-3517115-23-3519
1/02/03/0
53.567.485.0
1.091.121.17
1.151.191.23
808080
2.032.032.03
1.331.371.42
34.035.036.1
114012701420
127513801605
215255290
295335380
215245275
444
� 115-23-3521115-23-3523115-23-3527
4/0250350
107.0127.0177.0
1.231.271.36
1.291.331.43
808080
2.032.032.03
1.471.521.61
37.438.741.2
159517602150
180019502420
330365440
435475575
315345415
555
� 115-23-3531115-23-3535115-23-3537
500750
1000
253.0380.0507.0
1.481.661.81
1.541.721.86
80110110
2.032.792.79
1.731.972.12
43.950.153.9
272037654671
301442405300
535655755
700865
1005
500610690
566
� 115-23-3656115-23-3657115-23-3659
1/02/03/0
53.567.485.0
1.241.281.32
1.301.341.39
808080
2.032.032.03
1.491.531.57
37.939.040.0
135014701630
153516651825
215255290
295335380
215245275
555
� 115-23-3661115-23-3663115-23-3667
4/0250350
107.0127.0177.0
1.391.421.52
1.451.481.58
8080
110
2.032.032.79
1.641.691.83
41.942.946.5
184019852495
208522502770
330365440
435475575
315345415
555
115-23-3671115-23-3675115-23-3677
500750
1000
253.0380.0507.0
1.631.811.97
1.691.872.02
110110110
2.792.792.79
1.942.122.27
49.353.957.6
308540555980
355546805630
535655755
700865
1005
500610690
668
Visit Okonite's web site, www.okonite.com for the most up to date dimensions.
� Available from our Customer Service Centers.
(1) Aluminum Conductors are available on special orders.
(2) Ampacities are in accordance with Table 310.60(C)(73) of the NEC for threesingle Type MV-105 conductors, or single conductors twisted together(triplexed) and installed in an isolated conduit in air at an ambient temperatureof 40°C and a conductor temperature of 105°C.
(3) Ampacities are in accordance with Table 310.60(C)(81) of the NEC for aninsulated single conductor directly buried with a conductor temperature rating of105°C, ambient earth temperature of 20°C, 100% Load Factor, thermal resis-tance (RHO) of 90, 7 1/2 inch spacing between conductor center lines, and 24inch spacing between circuits.
(4) Ampacities are in accordance with Table 310.60(C)(77) of the NEC forthree single conductors or triplexed cable in one underground raceway, threefeet deep with a conductor temperature of 105°C, 100% Load Factor, an ambi-ent earth temperature of 20°C, and thermal resistance (RHO) of 90.
Refer to the NEC, IEEE/ICEA S-135 Power Cable Ampacities, or the OkoniteEngineering Data Bulletin for installation in duct banks, multiple point groundedshields, other ambient temperatures, circuit configurations or installation re-quirements.
(5) Recommended size of rigid or nonmetallic conduit for three conductorsbased on 40% maximum fill.
*The jam ratio conduit I.D. to cable O.D. should be checked to avoid possiblejamming.
J/15010216
Okoguard-Okoseal Type MV-105One Okopact (Compact Stranded)Copper Conductor/105°C Rating100% and 133% Insulation Level
ULR
THE OKONITE COMPANYRamsey, New Jersey 07446
Okoguard is Okonite’s registered tradename for its exclusive ethylene-propylene rubber (EPR) based, thermo-setting compound, whose optimumbalance of electrical and physical prop-erties is unequaled in other soliddielectrics. Okoguard insulation, with thedistinctive red color and a totally inte-grated EPR system, provides theoptimum balance of electrical and physi-cal properties for long, problem freeservice.The triple tandem extrusion of thescreens with the insulation provides op-timum electrical characteristics.
The Okoseal (PVC) jacket supplied withthis cable is mechanically rugged andhas excellent resistance to oil and mostchemicals.
Okoguard-Shielded-Okoseal 69kV Ca-bles are designed for use as primarycircuits in electrical utility and industryapplications where they provide maxi-mum circuit security and economicalinstallation. Rated 105°C for continuousoperating temperature, Okoguard 69kVcables may be installed in wet or dry lo-cations indoors or outdoors (exposed tosunlight) in underground ducts, conduitsor direct burial.
Uncoated copper sizes350 through 1000 kcmil compact roundstranding per ASTM B-496. Uncoatedcopper sizes larger than 1000 kcmilcompress round stranding per ASTMB-8. EC Aluminum per ASTM B609,Class B stranded per B-231.
Extruded semiconduct-ing EPR strand screen. Meets orexceeds electrical and physical require-ments of ICEA S-108-720, AEIC CS9.
Meets or exceeds electricaland physical requirements of ICEAS-108-720 and AEIC CS9.
Extruded semicon-ducting EPR insulation screen. Meetsor exceeds electrical and physical re-quirements of ICEA S-108-720 andAEIC CS9.
5 mil bare copper tape helicallyapplied with 25% nominal overlap.
Meets or exceeds electricaland physical requirements of ICEAS-108-720 for polyvinyl chloride jack-ets.Optional jackets include Okolene,Okolon TS-CPE, Okoclear and, whenspecified, a semi-conducting outerlayer.Optional shields include neutral wires,LCS and a combination of copper tapeand wires. A CLX armor covering isalso available.
• Triple tandem extruded, all EPRsystem.• Okoguard cables meet or exceed rec-ognized industry standards (AEIC,NEMA/ ICEA).• 105°C continuous operatingtemperature.• 140°C emergency rating.• 250°C short circuit rating.• Excellent corona resistance.• Exceptional resistance to “treeing.”• Low shield resistance.• Moisture resistant.• Resistant to most oils, acids, andalkalies.• Sunlight resistant.• Improved Temperature Rating.• Screens are clean stripping.
Okoguard®-Okoseal®
Conductor/105°C Rating — 100% Insulation Level
Uncoated, Okopact (Compact)or Compress Stranded Copperor Aluminum ConductorStrand Screen-Extruded Semi-conducting EPRInsulation-Okoguard EPRInsulation Screen-Extruded Semiconducting EPRShield- 5 Mil Uncoated CopperTapeJacket-Okoseal
Okoguard-Okoseal
Conductor/ 105°C Rating100% Insulation Level
115-22-3767� 115-22-3771
115-22-3775
350*500750
177253380
2.012.122.30
2.112.222.40
110110110
2.792.792.79
2.362.472.64
59.962.767.1
353841795213
387345145805
550667825
495599742
3 12
3 12
4
� 115-22-3777 1000 507 2.44 2.54 140 3.56 2.85 72.4 6389 7151 957 861 4
115-22-3778 1250 633 2.68 2.78 140 3.56 3.09 78.5 7582 8344 1066 959 5
115-22-3779 1500 761 2.78 2.88 140 3.56 3.19 81.0 8527 9447 1157 1042 5
135-22-3767135-22-3771135-22-3775
350*500750
177253380
2.062.192.37
2.162.292.47
110110110
2.792.792.79
2.412.542.72
61.264.569.1
288832443778
322335794175
429523650
386469584
3 12
3 12
4
135-22-3777135-22-3778
10001250
507633
2.522.68
2.622.78
140140
3.563.56
2.933.09
74.478.5
44334954
49045716
759853
683768
45
135-22-3779 1500 761 2.80 2.90 140 3.56 3.21 81.5 5381 6034 936 842 5
Visit Okonite's web site, www.okonite.com for the most up to date dimensions.
� Available from our Customer Service Centers.
(1) Ampacities are in accordance with ICEA P-53-426 for threesingle 69kV conductors directly buried or in individual ducts underground, 36"deep with 7 1/2" spacing between conductors, 105°C maximum conductor tem-perature, 25°C earth temperature, soil resistivity of 90 Rho, 100% load factor,and open circuit shields.
(2) Recommended size of rigid nonmagnetic or nonmetallic conduit for a singleconductor based on 53% maximum fill
* Minimum conductor size per, (1) AEIC CS-9 is 500 kcmil; (2) ICEA S-108-720is 250 kcmil.
E/13060218
THE OKONITE COMPANYRamsey, New Jersey 07446
Okoguard Is Okonite's registered trade namefor its exclusive ethylene-propylene rubber(EPR) base, thermosetting compound,whose optimum balance of electrical andphysical properties is unequaled in othersolid dielectrics. Okoguard insulation, withthe distinctive red color and a totally inte-grated EPR system, provides the optimumbalance of electrical and physical propertiesfor long, problem free service.
The Type MV-105 conductors are assembledwith fillers and a binder tape overall. Onebare stranded copper ground conductor isplaced in one of the outer interstices.
The Okoseal (PVC) jacket supplied with thiscable is mechanically rugged and has excel-lent resistance to oil and most chemicals.
Okoguard shielded three conductor TypeMV-105 power cables are recommended fordistribution circuits, and for feeders or branchcircuits in industrial & utility power distribu-tion systems. Type MV cables may beinstalled in wet or dry locations, indoors oroutdoors (exposed to sunlight), in any race-way or underground duct, directly buried,cable tray, or messenger supported in indus-trial establishments and electric utilities.
Uncoated copper compactstranded per ASTM B-496.
Extruded semiconductingEPR strand screen meets or exceeds electri-cal and physical requirements of ICEAS-93-639/NEMA WC74 and UL 1072.
Okoguard meets or exceeds theelectrical and physical requirements of ICEAS-93-639/NEMA WC74 and UL 1072. The in-sulated conductors are tested in accordancewith AEIC CS8.
Extruded semiconduct-ing EPR insulation screen per ICEAS-93-639/NEMA WC74, AEIC CS8 and UL1072.
5 mil uncoated copper tape helicallyapplied with 12.5% nominal overlap.
Color coded (black,red, blue) polyester ribbon laid longitudinallyunder the copper shield.
Uncoated cop-per compact stranded per ASTM B-496and sized in accordance with UL 1072.
Cabled with fillers and groundwire in the interstices, binder tape overall.
Meets or exceeds electrical andphysical requirements of ICEA S-93-639/NEMA WC74 and UL 1072 for polyvi-nyl chloride jackets.UL Listed as Type MV-105, sunlight re-sistant for use in cable tray, and for directburial in accordance with UL 1072.Cables listed to CSA C68.3 are alsoavailable.
• Triple tandem extruded, all EPR system.• Complete prepackaged, color coded,factory tested wiring system.• Passes the vertical tray flame test re-quirements of IEEE 383 and UL 1072.• Complies with NEC Sections 310-7 and710-4(b) for direct burial.• Excellent corona resistance.• Screens are clean stripping.• Exceptional resistance to “treeing”.• Improved Temperature Rating.
COMPACT STRAND
CONSTRUCTION
Okoguard® Okoseal® Type MV-105
3 Okopact® (Compact Stranded) Copper Conductors/105°C Rating5kV-133% or 8kV-100% Insulation Level
Uncoated Okopact (CompactStranded) Copper ConductorsExtruded Semiconducting EPRStrand ScreenOkoguard Insulation (EPR)Extruded Semiconducting EPRInsulation ScreenPhase Identification TapeOkopact Compact Copper Ground-ing ConductorUncoated Copper ShieldFillers and Binder TapeJacket-Black Okoseal
ULR
Okoguard Okoseal Type MV-1053 Okopact (Compact Stranded) Copper Conductors/105°C Rating5kV-133% or 8Kv-100% Insulation Level
� 114-23-3630114-23-3633
64
13.321.2
0.440.48
66
13.313.3
1.101.19
27.930.2
8080
2.032.03
1.291.38
32.835.1
10151235
11151390
88115
77100
115150
� 114-23-3640114-23-3642
21/0
33.653.5
0.540.61
64
13.321.2
1.321.46
33.537.0
8080
2.032.03
1.511.65
38.341.9
15602090
17152250
155205
135185
190245
� 114-23-3648� 114-23-3736
114-23-3770
2/04/0
250
67.4107.0127.0
0.650.750.80
433
21.226.726.7
1.551.771.88
39.445.047.8
110110110
2.792.792.79
1.802.022.13
45.751.354.1
251334553971
269537804245
240320355
210285315
280360395
� 114-23-3772� 114-23-3782
350500
177.0253.0
0.891.01
21
33.642.4
2.082.33
52.859.2
110110
2.792.79
2.332.59
59.265.8
51166799
56657430
440545
390475
475570
Visit Okonite's web site, www. okonite.com for the most up to date dimensions.
E/15010219
� Available from our Customer Service Centers.
Aluminum conductors available on special orders.
Ampacities are in accordance with Table 310.60(C)(71) of the NEC for aninsulated three conductor cable, isolated in air, with a conductor operating tem-perature of 105°C and an ambient air temperature of 40°C.
Ampacities are in accordance with Table 310.60(C)(75) of the NEC for athree conductor Type MV-105 cable installed in uncovered cable tray in accor-dance with Section 392.80(B) of the NEC with a conductor operatingtemperature of 105°C and ambient air temperature of 40°C. Where the cabletray is covered for more than six feet with solid unventilated covers, theampacities shall not be more than 95% of the values shown above.
Ampacities are in accordance with Table 310.60(C)(83) of the NEC for aninsulated three conductor cable directly buried in the earth with a conductor op-erating temperature of 105°C, ambient earth temperature of 20°C, 100% loadfactor and thermal resistance (RHO) of 90.Refer to the NEC, IEEE/ICEA S-135 Power Cable Ampacities, or the OkoniteEngineering Data Bulletin for installation in duct banks, other ambient tempera-tures, circuit configurations or installation requirements.
ULR
THE OKONITE COMPANYRamsey, New Jersey 07446
Okoguard Is Okonite's registered trade namefor its exclusive ethylene-propylene rubber(EPR) base, thermosetting compound,whose optimum balance of electrical andphysical properties is unequaled in othersolid dielectrics. Okoguard insulation, withthe distinctive red color and a totally inte-grated EPR system, provides the optimumbalance of electrical and physical propertiesfor long, problem free service.
The Type MV-105 conductors are assembledwith fillers and a binder tape overall. Onebare stranded copper ground conductor isplaced in one of the outer interstices.
The Okoseal (PVC) jacket supplied with thiscable is mechanically rugged and has excel-lent resistance to oil and most chemicals.
Okoguard shielded three conductor OkosealType MV-105 power cables are recom-mended for distribution circuits, and forfeeders or branch circuits in industrial andutility power distribution systems. Type MVcables may be installed in wet or dry loca-tions, indoors or outdoors (exposed tosunlight), in any raceway or undergroundduct, directly buried, cable tray, or messen-ger supported in industrial establishmentsand electric utilities.
Uncoated copper compactstranded per ASTM B-496.
Extruded semiconductingEPR strand screen meets or exceeds electri-cal and physical requirements of ICEAS-93-639/NEMA WC74 and UL 1072.
Okoguard meets or exceeds theelectrical and physical requirements of ICEAS-93-639/NEMA WC74 and UL 1072. The in-sulated conductors are tested in accordancewith AEIC CS8.
Extruded semiconduct-ing EPR insulation screen per ICEAS-93-639/NEMA WC74, AEIC CS8 and UL1072.
5 mil uncoated copper tape helicallyapplied with 12.5% nominal overlap.
Color coded (black,red, blue) polyester ribbon laid longitudinallyunder the copper tape shield.
Uncoated cop-per compact stranded per ASTM B-496and sized in accordance with UL 1072.
Cabled with fillers and groundwire in the interstices, binder tape overall.
Meets or exceeds electrical andphysical requirements of ICEAS-93-639/NEMA WC74 and UL 1072 forpolyvinyl chloride jackets. UL Listed asType MV-105, sunlight resistant for use incable tray, and for direct burial in accor-dance with UL 1072.Cables listed to CSA C68.3 are alsoavailable.
• Triple tandem extruded, all EPR system.• Complete prepackaged, color coded, fac-tory tested wiring system.• Passes the UL 1072 & IEEE 383 verticaltray flame test requirements.• Complies with NEC Sections 310-7 and710-4(b) for direct burial.• Excellent corona resistance.• Screens are clean stripping.• Exceptional resistance to “treeing”.• Improved Temperature Rating.
COMPACT STRAND
CONSTRUCTION
Okoguard Okoseal Type MV-105
3 Okopact (Compact Stranded) Copper Conductors/105°C Rating100% & 133% Insulation Level
ULR
Uncoated Okopact (CompactStranded) Copper ConductorsExtruded Semiconducting EPRStrand ScreenOkoguard Insulation (EPR)Extruded Semiconducting EPRInsulation ScreenPhase Identification TapeOkopact Copper GroundingConductorUncoated Copper ShieldFillers and Binder TapeJacket-Black Okoseal
Okoguard Okoseal Type MV-105
3 Okopact (Compact Stranded) Copper Conductors/105°C Rating100% & 133% Insulation Level
115-23-3766115-23-3768
21/0
33.653.5
0.670.74
64
13.321.2
1.591.74
40.444.2
110110
2.792.79
1.831.97
46.550.0
19852560
21302770
185240
165215
200255
115-23-3770115-23-3772115-23-3774
2/04/0
250
67.4107.0127.0
0.780.880.93
433
21.226.726.7
1.822.042.15
42.251.854.6
110110110
2.792.792.79
2.062.282.39
52.357.960.7
289039054390
315041904930
275360400
245320350
290375410
115-23-3776115-23-3778115-23-3780
350500750
177.0253.0380.0
1.031.141.32
21
1/0
33.642.453.5
2.362.612.99
59.966.375.9
110140140
2.793.563.56
2.592.913.29
65.873.983.6
56087480
10320
62108255
11330
490600745
430525635
495590720
� 115-23-3802115-23-3804
21/0
33.653.5
0.760.83
64
13.321.2
1.791.93
45.549.0
110110
2.792.79
2.022.17
51.355.1
22802857
25753145
185240
165215
200255
� 115-23-3806� 115-23-3808
115-23-3810
2/04/0
250
67.4107.0127.0
0.870.971.03
433
21.226.726.7
2.022.242.36
51.356.960.0
110110110
2.792.792.79
2.262.482.59
57.463.065.8
326042854795
357046405295
275360400
245320350
290375410
� 115-23-3812� 115-23-3814
115-23-3816
350500750
177.0253.0380.0
1.121.241.41
21
1/0
33.642.453.5
2.562.813.19
65.071.481.0
140140140
3.563.563.56
2.853.103.49
72.478.788.7
61687895
10805
70008945
11800
490600745
430525635
495590720
Visit Okointe's web site, www.okonite.com for the most up to date dimensions.
E/15010220
� Available from our Customer Service Centers.
Aluminum conductors available on special orders.
Ampacities are in accordance with Table 310.60(C)(71) of the NEC for aninsulated three conductor cable, isolated in air, with a conductor operating tem-perature of 105°C and an ambient air temperature of 40°C.
Ampacities are in accordance with Table 310.60(C)(75) of the NEC for athree conductor Type MV-105 cable installed in uncovered cable tray in accor-dance with Section 392.80(B) of the NEC with a conductor operatingtemperature of 105°C and ambient air temperature of 40°C. Where the cabletray is covered for more than six feet with solid unventilated covers, theampacities shall not be more than 95% of the values shown above.
Ampacities are in accordance with Table 310.60(C)(83) of the NEC for aninsulated three conductor cable directly buried in the earth with a conductor op-erating temperature of 105°C, ambient earth temperature of 20°C, 100% loadfactor, thermal resistance (RHO) of 90.
Refer to the NEC, lEEE/lCEA S-135 Power Cable Ampacities or the OkoniteEngineering Data Bulletin for installation in duct banks, other ambient tempera-tures, circuit configurations or installation requirements.
ULR
THE OKONITE COMPANYRamsey, New Jersey 07446
Okoguard is Okonite's registered trade namefor its exclusive ethylene-propylene rubber(EPR) base, thermosetting compound, whoseoptimum balance of electrical and physicalproperties is unequaled in other solid dielec-trics. Okoguard insulation, with the distinctivered color and a totally integrated EPR system,provides the optimum balance of electrical andphysical properties for long, problem free serv-ice.
The Type MV-90 conductors are assembledwith fillers and a binder tape into a round core.Three bare stranded copper grounding conduc-tors, located in the outer interstices, is providedfor grounding. A continuously corrugatedwelded aluminum sheath C-L-X encases thecable core. The C-L-X sheath is protected witha low temperature yellow Okoseal® (PVC)jacket. The impervious, continuous, corrugatedaluminum C-L-X sheath provides complete pro-tection against moisture, liquids and gases inaddition to its excellent mechanical strength.Also, the aluminum C-L-X sheath has adequateampacity capability to be used as a groundingconductor. The overall Okoseal (PVC) jacket al-lows the cable to be direct buried in the ground,embedded in concrete or areas subjected to acorrosive atmosphere.
C-L-X power cables are recommended as aneconomical alternate to a wire in conduit sys-tem. They are designed specifically for use onfeeders and branch circuits in industrial powerdistribution systems. C-L-X power cables maybe installed in both exposed and concealedwork, wet and dry locations, direct burial in theearth, or embedded in concrete. They may beinstalled on metal racks, troughs, in cable traysor secured to supports not greater than 6 feetapart. C-L-X power cables are also approvedfor Classes I, II and III. Divisions 1 and 2 andClass I, Zones 1 and 2 hazardous locations -NEC Articles 501, 502, 503 and 505.Medium voltage Non-Shielded cables dis-charge normally in service when spacingbetween phases is non-uniform or whenphases are in close proximity to a groundedsurface.
Annealed uncoated copper com-pact stranded per ASTM B-496.
Extruded semiconducting EPRstrand screen meets or exceeds electrical and
physical requirements of ICEAS-96-659/NEMA WC71 and UL 1072.
Okoguard meets or exceeds theelectrical and physical requirements ofICEA S-96-659/NEMA WC71 and UL 1072.
Print color code(black, red and blue).
Three uncoatedcopper Class B in accordance with UL 1072.
Cabled with fillers and groundwires, in the interstices, binder tape overall.
Close fitting, impervious, continu-ous, corrugated aluminum C-L-X per UL1072. C-L-X is recognized as a groundingconductor by NEC.
A low temperature sunlight resis-tant, yellow PVC jacket in accordance withUL 1072. Other color jackets are available.UL Listed as type MV-90 or MC-HL, sunlightresistant, for use in cable tray, and for directburial in accordance with UL 1072 and2225.
• Tandem extruded, all EPR system.
• Complete prepackaged, color coded, fac-tory tested wiring system.
• Okoguard C-L-X cables meet or exceedelectrical and physical requirements of allrecognized industry standards (UL, AEIC,NEMA/ICEA, IEEE).
• Passes the vertical tray flame test re-quirements of IEEE 383 and 1202, UL1072, ICEA T-29-520(210,000 BTU/hr.)
• Complies with NEC Sections 310-7 and300-50 for direct burial.
• Complies with NEC Articles 501, 502, 503and 505 for hazardous locations.
• Continuous sheath provides groundingsafety.
• Excellent corona resistance.
• Exceptional resistance to “treeing.”
• Stress cones not required.
• Minimum installation temperature of-40°C.
• Three symmetrical grounding conductorsfor PWM/VFD and other modern ACdrive/motor applications.
• ABS listed as CWCMC Type MC-HL.
• CSA listed as RA90, FT4, SR, HL, -40°Cand 5000V.
C-L-X® Type MV-90 or MC-HL®
3 Okopact® (Compact Stranded) Copper Conductors/90°C Rating100% and 133% Insulation Level
Uncoated, Okopact (CompactStranded) Copper ConductorExtruded Semiconducting EPRStrand ScreenOkoguard (EPR) InsulationThree Copper GroundingConductorsPhase IdentificationFillers and Binder TapeImpervious, Continuous,Corrugated Aluminum C-L-XSheathJacket- Low Temperature YellowOkoseal
ULR
4A
WG
CO
MPA
CT
CU
GRD
CLX
(UL)
C-L-X Type MV-90 or MC-HL
3 Okopact® (Compact Stranded) Copper Conductors/90°C Rating100% and 133% Insulation Level
571-21-3193571-21-3196
� 571-21-3200
864
8.413.321.2
0.360.390.44
3x123x103x10
0.770.850.97
19.621.624.6
0.971.061.19
505050
1.271.271.27
1.081.171.30
27.429.733.0
565740960
630820
1050
5979
105
526991
85105135
� 571-21-3204571-21-3208571-21-3212
21
1/0
33.642.453.5
0.500.520.56
3x103x83x8
1.101.161.23
27.929.431.2
1.341.421.51
505060
1.271.271.52
1.451.531.65
36.838.941.9
127015201835
147016601980
140160185
125140165
180200230
� 571-21-3217� 571-21-3224
571-21-3228
2/04/0
250
67.4107.0127.0
0.600.700.75
3x83x73x6
1.331.531.64
33.838.941.7
1.601.831.96
606060
1.521.521.52
1.731.962.09
43.949.853.1
216030753470
232533403725
215285320
190255280
260335365
� 571-21-3236� 571-21-3244
571-21-3248571-21-3252
350500750
1000
177.0253.0380.0507.0
0.850.961.141.29
3x63x53x43x4
1.862.102.512.90
47.253.363.873.7
2.192.452.933.41
60757585
1.521.911.912.16
2.322.613.103.59
58.966.378.791.2
470564059220
12075
526569659980
13155
395485615705
350425525590
440530650730
Visit Okonite's web site, www.okonite.com for the most up to date dimensions.
K/14010221
� Available from our Customer Service Centers.
Optional jacket types available - consult local sales office.
Aluminum conductors are available on special order.
Ampacities are in accordance with Table 310.71 of the NEC for an insulatedthree conductor cable, isolated in air, with a conductor operating temperature of90°C and an ambient air temperature of 40°C.
Ampacities are in accordance with Table 310.75 of the NEC for a three con-ductor Type MV-90 or MC cable installed in uncovered cable tray in accordancewith Section 392.13 of the NEC with a conductor operating temperature of 90°Cand ambient air temperature of 40°C. Where the cable tray is covered for morethan six feet with solid unventilated covers, the ampacities shall not be morethan 95% of the values shown above.
Ampacities are in accordance with Table 310.83 of the NEC for an insulatedthree conductor cable directly buried in the earth with a conductor operatingtemperature of 90°C, ambient earth temperature of 20°C, 100% load factor andthermal resistance (RHO) of 90.Refer to the NEC, IEEE/ICEA S-135 Power Cable Ampacity Tables, or theOkonite Engineering Data Bulletin for installation in duct banks, other ambienttemperatures, circuit configurations or installation requirements.C-L-X® The Okonite Company
THE OKONITE COMPANYRamsey, New Jersey 07446
ULR
Okoguard Is Okonite's registered trade name forits exclusive ethylene-propylene rubber (EPR)base, thermosetting compound, whose optimumbalance of electrical and physical properties isunequaled in other solid dielectrics. Okoguardinsulation, with the distinctive red color and atotally integrated EPR system, provides theoptimum balance of electrical and physicalproperties for long, problem free service.
Type MV-105 conductors are assembled withfillers, three bare stranded grounding conductorsand a binder tape into a round core. A continu-ously corrugated welded aluminum sheath(C-L-X) encases the cable core. The C-L-Xsheath is protected with a low temperatureyellow Okoseal® jacket. The impervious, con-tinuous, corrugated aluminum C-L-X sheathprovides complete protection against moisture,liquids and gases in addition to its excellent me-chanical strength. In addition, the aluminumsheath has adequate ampacity capability to beused as a grounding conductor in non HL areas.The Okoseal jacket allows the cable to be directburied in the ground, embedded in concrete orareas subjected to corrosive atmospheres.
C-L-Xpower cables are recommended as aneconomical alternate to a wire in conduit system.They are designed specifically for use as feed-ers or branch circuits in industrial and utilitypower distribution systems. C-L-Xpower cablesmay be installed in both exposed and concealedwork, wet and dry locations, directly buried in theearth, or embedded in concrete. They may beinstalled on metal racks, troughs, in cable traysor secured to supports not greater than 6 feetapart.C-L-X Type MC-HL cables are also approved forClasses I, II, and III, Division 1 and 2 and ClassI, Zones 1 and 2 hazardous locations - NEC Ar-ticles 501, 502, 503 and 505.
Uncoated copper compactstranded per ASTM B-496.
Extruded semiconducting EPRstrand screen meets or exceeds electrical andphysical requirements of ICEA S-93-639/NEMAWC74 and UL 1072.
Okoguard meets or exceeds theelectrical and physical requirements of ICEA S-93-639/NEMA WC74 and UL 1072. The insu-lated conductors are tested in accordance withAEIC CS8.
Extruded semiconduct-ing EPR insulation screen per ICEAS-93-639/NEMA WC74, AEIC CS8 and UL1072.
5 mil uncoated copper tape helicallyapplied with 12.5% nominal overlap.
Color coded (black,red, blue) polyester ribbon laid longitudinallyunder the copper shield tape.
Three uncoatedcopper in accordance with UL 1072.
Cabled with fillers and groundwires in the interstices, binder tape overall.
Close fitting, impervious, continu-ous, corrugated aluminum C-L-Xper UL1072; C-L-X is recognized as a groundingconductor by NEC.
A low temperature, sunlight resis-tant, yellow PVC jacket in accordance withUL 1072. Other color jackets are available.UL Listed as type MV-105 or MC-HL, sun-light resistant for use in cable tray, and fordirect burial in accordance with UL 1072 &2225. CSA Listed to C68.3.
• Triple tandem extruded, all EPR system.• Complete prepackaged, color coded, factorytested wiring system.• Okoguard C-L-X cables meet or exceed allrecognized industry standards (UL, AEIC,NEMA/ICEA, IEEE).• Passes the vertical tray flame test require-ments of IEEE 383 and 1202, UL 1072,ICEA T-29-520 (210,000 BTU/hr.).• Complies with NEC Sections 310.7 and300.50 for direct burial.• Complies with NEC Articles 501, 502, 503 and505 for hazardous locations.• Continuous sheath provides grounding safety.• Excellent corona resistance.• Screens are clean stripping.• Exceptional resistance to “treeing”.• Minimum installation temperature of -40°C.• Improved Temperature Rating.• Three symmetrical grounding conductorsfor PWM/VFD and other modern ACdrive/motor applications.• ABS listed as CWCMC Type MC-HL.• CSA listed as FT4 and LTGG (-40°C).
C-L-X® Type MV-105 or MC-HL5/8kV Okoguard
®Shielded Power Cable-Aluminum Sheath
3 Okopact (Compact Stranded) Copper Conductors/105°C Rating5kV-133% or 8kV-100% Insulation Level
Uncoated (Compact Stranded)Copper ConductorsExtruded Semiconducting EPRStrand ScreenOkoguard Insulation (EPR)Extruded Semiconducting EPRInsulation ScreenPhase Identification TapeThree Copper GroundingConductorsUncoated Copper ShieldFillers and Binder TapeImpervious, continuous,Corrugated Aluminum C-L-X SheathJacket-Yellow Okoseal
ULR
C-L-X Type MV-105 or MC-HL3 Okopact (Compact Stranded) Copper Conductors/105°C Rating100% and 133% Insulation Level
*571-22-3694571-22-3696571-22-3698
864
8.413.321.2
0.400.440.48
3x123x103x10
1.041.121.21
26.428.430.7
1.291.371.51
505060
1.271.271.52
1.401.481.65
35.637.641.9
90710901398
105612591556
6688
115
5877
100
90115150
� 571-22-3706571-22-3708571-22-3710
21
1/0
33.642.453.5
0.540.580.61
3x103x83x8
1.341.401.48
34.035.637.6
1.641.691.78
606060
1.521.521.52
1.781.821.91
45.246.248.5
173219922273
189021373012
154180205
135155185
190215245
� 571-22-3717� 571-22-3725
571-22-3727
2/04/0
250
67.4107.0127.0
0.650.750.80
3x83x73x6
1.571.781.90
39.945.248.3
1.922.152.28
606060
1.521.521.52
2.002.292.44
50.858.262.0
261636134175
417139804390
240320355
210285315
280360395
� 571-22-3838� 571-22-3846
571-22-3748571-22-3751
350500750
1000
177.0253.0380.0507.0
0.891.011.191.34
3x63x53x43x4
2.102.352.733.06
53.357.669.377.7
2.452.753.243.64
75758585
1.911.912.162.16
2.612.913.423.81
66.373.986.996.8
53287095
1013412966
54357603
1102114596
440545685790
390475585660
475570700785
* This cable is only rated 5kV (133%), due to UL limitations, it cannot be rated 8kV.Visit Okonite's web site, www.okonite.com for the most up to date dimensions.
K/15010222
� Available from our Customer Service Centers.
Optional jacket types available - consult local sales office.
Aluminum conductors are available on special order.
Ampacities are in accordance with Table 310.60(C)(71) of the NEC for aninsulated three conductor cable, isolated in air, with a conductor operating tem-perature of 105°C and an ambient air temperature of 40°C.
Ampacities are in accordance with Table 310.60(C)(75) of the NEC for athree conductor Type MV-105 or MC cable installed in uncovered cable tray in
accordance with Section 392.80(B) of the NEC with a conductor operating tem-perature of 105°C and ambient air temperature of 40°C. Where the cable tray iscovered for more than six feet with solid unventilated covers, the ampacitiesshall not be more than 95% of the values shown above.
Ampacities are in accordance with Table 310.60(B)(83) of the NEC for an in-sulated three conductor cable directly buried in the earth with a conductoroperating temperature of 105°C, ambient earth temperature of 20°C, 100% loadfactor and thermal resistance (RHO) of 90.Refer to the NEC, IEEE/ICEA S-135 Power Cable Ampacity Tables, or the Ok-onite Engineering Data Bulletin for installation in duct banks, other ambienttemperatures, circuit configurations or installation requirements.C-L-X® The Okonite Company
ULR
THE OKONITE COMPANYRamsey, New Jersey 07446
A
B
C
DEF
G
K
J
H
Okoguard is Okonite's registered tradename for its exclusive ethylene-propylenerubber (EPR) base, thermosetting com-pound, whose optimum balance of electricaland physical properties is unequaled in othersolid dielectrics. Okoguard insulation, withthe distinctive red color and a totally inte-grated EPR system, provides the optimumbalance of electrical and physical propertiesfor long, problem free service.
The Type MV-105 conductors are assembledwith fillers, one bare stranded grounding con-ductor and a binder tape into a round core. Acontinuously corrugated welded aluminumsheath (C-L-X) encases the cable core. TheC-L-X sheath is protected with a low tem-perature red Okoseal® jacket. Theimpervious, continuous, corrugated alumi-num C-L-X sheath provides completeprotection against moisture, liquids andgases in addition to its excellent mechanicalstrength. In addition, the aluminum sheathhas adequate ampacity capability to be usedas a grounding conductor in non HL areas.The Okoseal jacket allows the cable to be di-rect buried in the ground, embedded inconcrete or areas subjected to corrosive at-mospheres.
C-L-X power cables are recommended as aneconomical alternate to a wire in conduit sys-tem. They are designed specifically for useas feeders or branch circuits in industrial andutility power distribution systems. C-L-Xpower cables may be installed in both ex-posed and concealed work, wet and drylocations, direct burial in the earth, or em-bedded in concrete. They may be installedon metal racks, troughs, in cable trays or se-cured to supports not greater than 6 feetapart.C-L-X Type MC-HL cables are also approvedfor Classes I, II, and III, Divisions 1 and 2and Class I , Zones 1 and 2 hazardous loca-tions - NEC Articles 501, 502, 503 and 505.
Uncoated copper compactstranded per ASTM B-496.
Extruded semiconductingEPR strand screen meets or exceeds electri-cal and physical requirements of ICEAS-93-639/NEMA WC74 and UL 1072.
Okoguard meets or exceeds theelectrical and physical requirements of ICEAS-93-639/NEMA WC74 and UL 1072. The in-sulated conductors are tested in accordancewith AEIC CS8.
Extruded semicon-ducting EPR insulation screen meets orexceeds electrical and physical require-ments of ICEA S-93-639/NEMA WC74and UL 1072.
5 mil uncoated copper tape heli-cally applied with 12.5% nominal overlap.
Color coded(black, red, blue) polyester ribbon laidlongitudinally under the copper shieldtape.
Uncoated cop-per in accordance with UL 1072.
Cabled with fillers and groundwire in the interstices, binder tape overall.
Close fitting, impervious, con-tinuous, corrugated aluminum C-L-X perUL 1072; C-L-X is recognized as agrounding conductor by NEC.
A low temperature, sunlight re-sistant, red PVC jacket in accordancewith UL 1072. Other color jackets areavailable.UL Listed as type MV-105 or MC-HL,sunlight resistant, for use in cable tray,and for direct burial in accordance withUL 1072 and 2225. UL certified to IEEE1580. CSA Listed to C68.3.
• Triple tandem extruded, all EPR system.• Complete prepackaged, color coded,factory tested wiring system.• Okoguard C-L-X cables meet or exceedall recognized industry standards (UL,AEIC, NEMA/ICEA, IEEE).• Passes the vertical tray flame test re-quirements of IEEE 383 and 1202, UL1072, ICEA T-29-520 (210,000 BTU/hr.)• Complies with NEC Sections 310.7 and300.50 for direct burial.• Complies with NEC Articles 501, 502,503 and 505 for hazardous locations.• Continuous sheath provides groundingsafety.• Excellent corona resistance.• Screens are clean stripping.• Exceptional resistance to “treeing”.• Minimum installation temperature of-40°C.• Improved Temperature Rating.• ABS listed as CWCMC Type MC-HL.• CSA listed as FT4 and LTGG (-40°C).
C-L-X® Type MV-105 or MC-HL®
3 Okopact® (Compact Stranded) Copper Conductors/105°C Rating133% Insulation Level
Uncoated Okopact (CompactStranded) Copper ConductorsExtruded Semiconducting EPRStrand ScreenOkoguard Insulation (EPR)Extruded Semiconducting EPRInsulation ScreenPhase Identification TapeCopper Grounding ConductorUncoated Copper ShieldFillers and Binder TapeImpervious, Continuous,
Corrugated Aluminum C-L-X SheathJacket-Red Low TemperatureOkoseal
ULR
C-L-X Type MV-105 or MC-HL15kV Okoguard Shielded Power Cable-Aluminum Sheath3 Okopact (Compact Stranded) Copper Conductors/105°C Rating133% Insulation Level
� 571-23-3504571-23-3508571-23-3512
21
1/0
33.642.453.5
0.760.790.83
644
1.791.861.94
45.547.349.3
2.152.232.32
606075
1.521.521.91
2.282.362.48
57.960.063.0
242027063076
314734043674
185210240
165185215
200225255
� 571-23-3516� 571-23-3524
571-23-3528
2/04/0
250
67.4107.0127.0
0.870.971.03
432
2.032.242.36
51.657.060.0
2.412.632.76
757575
1.911.911.91
2.572.792.92
65.370.974.2
343444605078
421953855845
275360400
245320350
290345410
� 571-23-3536� 571-23-3544� 571-23-3548
350500750
177.0253.0380.0
1.121.241.41
21
1/0
2.562.813.19
65.071.481.0
2.983.283.76
757585
1.911.912.16
3.143.463.94
79.889.2
100.0
62648221
11317
73059653
13087
490600745
430525635
495590720
Visit Okonite's web site, www.okonite.com for the most up to date dimensions.
K/15010224
� Available from our Customer Service Centers.
Optional jacket types available - consult local sales office.
Copper or bronze C-L-X and non-jacketed C-L-X are available on special order.
Aluminum conductors are available on special order.
Ampacities are in accordance with Table 310.60(B)(71) of the NEC for aninsulated three conductor cable, isolated in air, with a conductor operating tem-perature of 105°C and an ambient air temperature of 40°C.
Ampacities are in accordance with Table 310.60(B)(75) of the NEC for athree conductor Type MV-105 or MC cable installed in uncovered cable tray inaccordance with Section 392.80(B) of the NEC with a conductor operating tem-perature of 105°C and ambient air temperature of 40°C. Where the cable tray
is covered for more than six feet with solid unventilated covers, the ampacitiesshall not be more than 95% of the values shown above.
Ampacities are in accordance with Table 310.60(B)(83) of the NEC for aninsulated three conductor cable directly buried in the earth with a conductor op-erating temperature of 105°C, ambient earth temperature of 20°C, 100% loadfactor, thermal resistance (RHO) of 90.
Refer to the NEC, IEEE/ICEA S-135 Power Cable Ampacity Tables, or theOkonite Engineering Data Bulletin for installation in duct banks, other ambienttemperatures, circuit configurations or installation requirements.
C-L-X® The Okonite Company
ULR
THE OKONITE COMPANYRamsey, New Jersey 07446
Okonite's impregnated paper insulation con-sists of the finest electrical grade paper madefrom coniferous wood pulp and the purestgrade polybutene dielectric fluid. The paper ismanufactured to Okonite's specifications toproduce the necessary mechanical and physi-cal properties to resist tearing and wrinklingduring manufacture and subsequent handlingduring installation conditions; and in addition,to assure properties of low dielectric loss withhigh dielectric strength. Okonite pretwists thesectors of 3/C cables before taping to virtuallyeliminate wrinkles at the cabling machine. Tomaintain a smooth, wrinkle-free preciselygapped tape insulation, Okonite carefully slitsits own taping pads into widths tailored foreach conductor size and wall thickness. Mostimportant, Okonite has the latest taping ma-chines with the most precise tape tensioncontrols available today.The impregnating fluids used are of mediumviscosity (high viscosity optional) polybutenetypes, also manufactured to Okonite specifica-tions. Polybutene dielectric fluids are betterthan natural petroleum based insulating fluidsbecause they resist aging, have lower andmore stable power factor values and possessan inherent tackiness which resists drainingout of the paper tapes. Okonite's impregnationfacilities clay-filter and degas the dielectric flu-ids to provide low power factors and stableionization levels from voltage stress.
Okonite's copper bearing lead sheath providesan impervious barrier from the environment; inaddition, it provides mechanical protection forthe insulation and encapsulation of the im-pregnant. All lead sheaths have the inherentcapacity for substantial electrical conductivity,even under short circuit conditions without re-quiring a separate ground. Okonite's leadsheaths are applied with a continuous lead ex-truder under the control of a thickness gaugefor uniform wall thickness and concentricity ofextrusion.The Okolene jacket provides mechanical andcorrosion protection for the lead sheath and isused in most installations. (Indoor and aerialinstallations may not require a jacket). Ok-olene is a thermoplastic polyethylene materialthat resists most chemicals and moisture; it isunaffected by oils below 60°C and has a low
coefficient of friction which aids pullingthrough ducts and conduits.
Okonite Paper Insulated Lead Covered3/C cable is recommended for use in un-derground ducts, direct buried, and aeriallywhen lashed to a messenger. PILC cablesare used in any circuit that requires thehighest reliability, the longest uninterruptedservice life, and where the greatest surge,impulse and AC dielectric strength is de-sired. An added advantage is that a 3/CPILC cable permits the largest amount ofpower to be transmitted in the smallest di-ameter space because of its uniquetriangle shaped and nested design.Although not shown as an insulation above600 Volts in the National Electrical Code, itis readily approved for use by local inspec-tors because of its extensive safe use byutilities. Therefore, PlLC cables can beused in industrial or commercial applica-tions with prior notification and approval bythe local inspector.Also available in other voltage ratings.
Okonite PILC cables are manufactured inaccordance with and meet the require-ments of AEIC CS1-12 12th Edition.
• Pre-twisted conductors.• Polybutene impregnating fluid.• 90°C continuous operating temperature.• 110°C emergency rating.• 200°C short circuit rating.• High impulse strength.• Proven service life of over 60 years.• Impervious to environment.• Also available with LS/ZH Okoclear TP(TPPO) Okoseal (PVC) and ROC (Rein-forced Okonite Covering).
Solid Type PILC
Three Copper Conductors/90°C Rating100% Insulation Level
Conductors-StrandedCompact Sector, Pre-twistedStrand Screen-CarbonBlack Paper TapesInsulation- ImpregnatedPaper TapesInsulation Screen-CarbonBlack Paper TapeShield Copper TapeFillers-ImpregnatedPaperBinder Copper TapeSheath-Copper Bearing LeadJacket-Okolene (PE)
Solid Type PILC
Three Copper Conductors/90°C Rating100% Insulation Level
101-63-4120101-63-4175
21
33.642.4
180165
4.64.2
9090
9090
1.921.94
4.344.53
146167
149171
101-63-4243 1/0 53.5 165 4.2 90 90 1.97 4.83 191 197
101-63-4277101-63-4335101-63-4373
2/03/04/0
67.485.0
107.0
165165165
4.24.24.2
909095
909090
1.922.002.12
4.805.326.13
215245280
222256295
101-63-4436101-63-4553*
� 101-63-4544
250350350
127.0177.0177.0
165165165
4.24.24.2
95100100
909090
2.192.372.37
6.678.148.19
307371371
327402402
101-63-4666*� 101-63-4665
101-63-4904101-63-4986
500500750
1000
253.0253.0380.0507.0
165165165165
4.24.24.24.2
105105110120
110110110110
2.642.642.943.29
10.3110.3713.7117.33
450450555636
498498631740
*Zinc Shielding Tape in lieu of Copper
E/14090231
� Stock Items with copper shield tapes, copperbinder tape and high viscosity polybutene impregnating fluid.Available from our Customer Service Centers.
(1) One circuit, 90°C conductor, RHO 90 and 20°C earth ambient tem-eratures, 100% load factor.
(2) One circuit or multiple circuits spaced a cable diameter or more apart,40°C ambient air temperature, 40 to 100% load factor.
THE OKONITE COMPANYRamsey, New Jersey 07446
Okoguard is Okonite's registered tradename for its exclusive ethylene-propylenerubber (EPR) based, thermosetting com-pound, whose optimum balance ofelectrical and physical properties is un-equaled in other solid dielectrics.Okoguard insulation, with the distinctivered color and a totally integrated EPRsystem, provides the optimum balance ofelectrical and physical properties for long,problem free service.The triple tandem extrusion of thescreens with the insulation provides opti-mum electrical characteristics.An insulation screen of ethylene-propylene rubber is extruded over the in-sulation. The bare copper concentricwires are uniformly spaced around the in-sulation screen. The overall polyethylenejacket provides protection against me-chanical damage and corrosion.Product identification is provided throughthe use of three red stripes placed 120°apart in the black jacket with an NESClightning bolt.
Okoguard URO-J cables provide maxi-mum circuit longevity in undergroundresidential distribution systems. They canbe buried directly or installed in under-ground ducts or conduits.
Aluminum perASTM B-609, Class B stranded per B-231.
Extruded semicon-ducting ethylene-propylene rubber meetsor exceeds the requirements of ICEA S-94-649 and AEIC CS8.
Extruded Okoguard meets orexceeds the requirements of ICEA S-94-649 for ethylene-propylene rubber andAEIC CS8.
Extruded semicon-ducting ethylene-propylene rubber meetsor exceeds the requirements of ICEA S-94-649 and AEIC CS8.
Bare copperwires.
Black Okolene with red ex-truded stripes meets or exceeds therequirements of ICEA S-94-649 forpolyethylene jackets.
• Triple tandem extruded, all EPRsystem• Okoguard cables meet or exceedICEA and RUS 7CFR 1728.204 stan-dards.• 105°C continuous operating tem-perature.• 140°C emergency rating.• 250°C short circuit rating.• Excellent corona resistance.• Low dielectric constant and powerfactor.• Screens are clean stripping.• Exceptional resistance to “treeing”.• Moisture resistant.• Overall jacket provides extended life.• Red extruded stripes.• Excellent resistance to mostchemicals.• Can be listed as Type MV-90 for usein accordance with Article 328 of theNEC on special orders.• Cable CSA Listed to C68.5 onspecial orders.• Design Options:
Additional conductor sizesFilled strandCopper central conductorCopper flat strap concentric neutralProduct identification via coloredjackets.Semiconducting jacket
• Improved Temperature Rating.Okoguard insulation system has beentested and qualified for operation at105°C continuous and 140°C emer-gency operating temperature.• Minimum installation temperature of-40°C.
Okoguard® URO-J
Aluminum Conductor/105°C Rating100% and 133% Insulation Levels
Conductor-Stranded AluminumStrand Screen-Extruded Semiconducting EPRInsulation-Okoguard-EPRInsulation Screen-Extruded Semiconducting EPRConcentric Conductor-BareCopper WiresEncapsulating Jacket-Okolenewith 3 extruded red ID stripesand NESC lightning bolt
Okoguard URO-J
Aluminum Conductor/105°C Rating100% Insulation Level
161-23-2057� 161-23-2060
161-23-2066161-23-2069
2(1x)2(7x)
1(19x)1/0(1x)
0.660.670.720.72
0.730.750.800.80
10 x 1410 x 1413 x 1416 x 14
0.970.981.031.04
513517608657
603568698747
165165185210
120120135155
180180205235
130130150170
� 161-23-2072161-23-2075161-23-2078
1/0(19x)2/0(19x)3/0(19x)
0.750.810.86
0.830.880.93
16 x 1413 x 1216 x 12
1.061.151.20
667820939
725910
1029
235240270
170175200
235270305
170200225
161-23-2081161-23-2084161-23-2090
4/0(19x)250(37x)350(37x)
0.910.971.07
0.991.041.17
13 x 1016 x 1020 x 10
1.301.361.49
113813021615
123814181793
310340405
230255300
650385455
260285340
160-23-2057160-23-2060160-23-2066160-23-2069
2(1x)2(7x)
1(19x)1/0(1x)
0.660.680.720.72
0.730.760.800.80
6 x 146 x 146 x 146 x 14
0.971.001.031.04
467489527541
528579617663
155155175200
135135155175
165165190215
130130150175
160-23-2072160-23-2075160-23-2078160-23-2081
1/0(19x)2/0(19x)3/0(19x)4/0(19x)
0.760.810.860.91
0.840.880.930.99
6 x 147 x 149 x 1411 x 14
1.071.121.171.23
572636722822
662726889922
200230260290
175200230240
215245280315
175195225225
160-23-2084160-23-2090160-23-2093
250(37x)350(37x)500(37x)
0.971.071.20
1.041.171.30
13 x 1418 x 1416 x 12
1.281.411.57
91811661513
101813151691
320380455
260320385
345415495
280345415
160-23-2096160-23-2099
750(61x)1000(61x)
1.391.54
1.491.68
15 x 1018 x *(A)
1.872.06
21522711
24023059
555645
470550
600685
510585
* - Special Conductor Size (A) Wire O.D. =0.1066"(1) Individual wire size and count may vary. The resulting combination meets the 1/3 or full neutral,size requirement.
Visit Okonite's web site www.okonite.com for the most up to date dimensions.
� Available from our Customer ServiceCenters.
(2) Full neutral, single phase ampacities are based on 90°C or105°C conductor temperature, 20°C ambient temperature,100% load factor, and earth thermal resistivity of RHO 90.One third neutral ampacities are based on ICEA P-53-426triplexed or triangular configuration for the same conditionsstated above.
Okoguard URO-J
Aluminum Conductor/105°C Rating133% Insulation Levels
� 161-23-3057� 161-23-3060
161-23-3066� 161-23-3069
2(1x)2(7x)
1(19x)1/0(1x)
0.740.770.810.81
0.820.840.890.89
10 x 1410 x 1413 x 1416 x 14
1.061.081.131.12
577595691726
635662781792
165165185210
120120135170
180180205235
130130150170
� 161-23-3072161-23-3075161-23-3078
1/0(19x)2/0(19x)3/0(19x)
0.840.900.95
0.920.971.02
16 x 1413 x 1216 x 12
1.151.241.29
752912
1036
81810121136
210240270
170175200
235270305
170200225
161-23-3081161-23-3084161-23-3090
4/0(19x)250(37x)350(37x)
1.011.061.17
1.081.161.27
13 x 1016 x 1020 x 10
1.391.481.58
124114411734
135716191912
310340405
230255300
650385455
260285340
160-23-3057160-23-3060160-23-3066160-23-3069
2(1x)2(7x)
1(19x)1/0(1x)
0.750.780.810.82
0.820.850.890.89
6 x 146 x 146 x 146 x 14
1.061.091.131.13
544569610625
621659700715
155155175200
135135155175
165165190215
130130150175
160-23-3072160-23-3075160-23-3078
� 160-23-3081
1/0(19x)2/0(19x)3/0(19x)4/0(19x)
0.850.900.950.99
0.930.971.021.06
6 x 147 x 149 x 1411 x 14
1.171.211.261.30
658726816889
748826916
1002
200230260290
175200230240
215245280315
175195225255
160-23-3084160-23-3090160-23-3093
250(37x)350(37x)500(37x)
1.061.171.29
1.161.271.39
13 x 1418 x 1416 x 12
1.401.501.73
105212801709
116814581959
320380455
260320385
345415495
280345415
� 160-23-3096160-23-3099
**160-23-9592
750(61x)1000(61x)1100(61x)
1.481.641.62
1.581.771.75
15 x 1018 x *(A)12 x 14**
1.962.152.05
223728752307
251832232593
555645700
470550590
600685760
510585645
* - Special Conductor Size (A) Wire O.D. =0.1066"** - Special design 7% neutral, Compact Conductor(1) Individual wire size and count may vary. The resulting combination meets the 1/3 or full neutral,size requirement.
Visit Okonite's web site www.okonite.com for the most up to date dimensions.
(2) Full neutral, single phase ampacities are based on 90°Cconductor temperature, 20°C ambient temperature, 100% loadfactor, earth thermal resistivity of RHO 90 and 36" depth of burial.
One third neutral ampacities are based on ICEA P-53-426triplexed or triangular configuration for the same conditionsstated above. THE OKONITE COMPANY
Ramsey, New Jersey 07446F/14020235
Okoguard is Okonite's registered trade namefor its exclusive ethylene-propylene rubber(EPR) based, thermosetting compound,whose optimum balance of electrical andphysical properties is unequaled in othersolid dielectrics. Okoguard insulation, withthe distinctive red color and a totally inte-grated EPR system, provides the optimumbalance of electrical and physical propertiesfor long, problem free service.The triple tandem extrusion of the screenswith the insulation provides optimum electri-cal characteristics.The compressed conductors are filled withwater swellable powder. This constructionslows the migration of water through thestrands in the event of a mechanical dig-infollowed by external exposure to water.An insulation screen of ethylene-propylenerubber is extruded over the insulation. Thecopper concentric wires are uniformlyspaced around the insulation screen. Theoverall polyethylene jacket provides protec-tion against mechanical damage andcorrosion.Product identification is provided through theuse of three red stripes placed 120° apart inthe black jacket, with an NESC lightning bolt.
Okoguard URO-J cables provide maximumcircuit longevity in underground residentialdistribution systems. They can be buried di-rectly or installed in underground ducts orconduits.
Aluminum per ASTMB-609, Class B stranded per B-231.
Water swellable powdermeets or exceeds ICEA T-31-610 waterpenetration resistance and ANSI/NEMAclass A connectorability requirements.
Extruded semiconuctingethylene-propylene rubber meets or exceedsthe requirements of ICEA S-94-649 andAEIC CS8.
Extruded Okoguard meets or ex-ceeds the requirements of ICEA S-94-649and AEIC CS8.
Extruded semiconduct-ing ethylene-propylene rubber meets orexceeds the requirements of ICEAS-94-649 and AEIC CS8.
Bare copper wires.Black Okolene with red extruded
stripes meets or exceeds the require-ments of ICEA S-94-649 for polyethylenejackets.
Triple tandem extruded, all EPR system.
Okoguard cables meet or exceedNEMA/ICEA and RUS 7CFR 1728.204standards.
105°C continuous operating temperature.140°C emergency rating.250°C short circuit rating.Excellent corona resistance.
Low dielectric constant and power factor.
Screens are clean stripping.
Exceptional resistance to “treeing”.
Filled strand conductor.
Moisture resistant.Overall jacket provides extended life.
Excellent resistance to most chemicals.
Can be listed by UL as Type MV-90 onspecial orders.
Cable listed by CSA to C68.5 on specialorders.
Design Options:Additional conductor sizesCopper central conductorCopper flat strap concentric neutralProduct identification via colored jackets.Semiconducting jackets.
Improved Temperature Rating.Okoguard insulation system has beentested and qualified for operation at105°C continuous and 140°C emergencyoperating temperature.
Minimum installation temperature of-40°C.
Okoguard® URO-J
Filled Strand Aluminum Conductor/105°C Rating100% and 133% Insulation Levels
Conductor - Stranded Aluminumwith Filled Strand - Water SwellablePowerStrand Screen - Extruded Semi-conducting EPRInsulation - Okoguard EPRInsulation Screen - Extruded Semi-conducting EPRConcentric Conductor-Bare CopperWiresEncapsulating Jacket-Okolene withExtruded ID Stripes & NESClightning bolt
Okoguard URO-J
Filled Strand Aluminum Conductor/105°C Rating100% Insulation Level
163-23-2060163-23-2066
**163-23-2072163-23-2075
2(7x)1(19x)
1/0(19x)2/0(19x)
0.680.720.760.81
0.760.800.840.88
10 x 1413 x 1416 x 1413 x 12
1.001.031.071.15
536608688820
626698778910
165185210240
120135155175
180205235270
130150170200
163-23-2078163-23-2081163-23-2084163-23-2090
3/0(19x)4/0(19x)250(37x)350(37x)
0.860.910.971.07
0.930.991.041.17
16 x 1213 x 1016 x 1020 x 10
1.201.301.361.49
939113813021615
1029123814181793
270310340405
200230255300
305350385455
225260285340
162-23-2060162-23-2066162-23-2072
2(7x)1(19x)
1/0(19x)
0.680.720.76
0.760.800.84
6 x 146 x 146 x 14
1.001.031.07
489527572
579617662
155175200
135155175
165190215
130150175
162-23-2075162-23-2078162-23-2081162-23-2084
2/0(19x)3/0(19x)4/0(19x)250(37x)
0.810.860.910.97
0.880.930.991.04
7 x 149 x 1411 x 1413 x 14
1.121.171.231.28
636722822918
726889922
1018
230260290320
200230240260
245280315345
195225255280
162-23-2090162-23-2093162-23-2096162-23-2099
350(37x)500(37x)750(61x)
1000(61x)
1.071.201.391.54
1.171.301.491.68
18 x 1416 x 1215 x 10
18 x *(B)
1.411.571.872.06
1166151321522711
1315169124023059
380455555645
320385470550
415495600685
345415510585
* - Special Conductor Size (A) Wire O.D. =0.1066"Stocked as unfilled strand as 161-23-2072, see Sec 2, Sheet 35.
(1) Individual wire size and count may vary. The resulting combination meets the 1/3 or full neutral, sizerequirement.
Visit Okonite's web site www.okonite.com for the most up to date dimensions.
(2) Full neutral, single phase ampacities are based on 90°C or105°C conductor temperature, 20°C ambient temperature, 100%load factor, and earth thermal resistivity of RHO 90.One third neutral ampacities are based on ICEA P-53-426triplexed or triangular configuration for the same conditionsstated above.
Okoguard URO-J
� 163-23-3060163-23-3066
� 163-23-3072163-23-3075
2(7x)1(19x)
1/0(19x)2/0(19x)
0.770.820.840.91
0.850.900.920.98
10 x 1413 x 1416 x 1413 x 12
1.081.141.151.25
602694753916
669766820996
165185210240
120135155175
180205235270
130150170200
163-23-3078163-23-3081163-23-3084163-23-3090
3/0(19x)4/0(19x)250(37x)350(37x)
0.961.021.071.18
1.041.091.171.28
16 x 1213 x 1016 x 1020 x 10
1.311.411.481.59
1045125214561762
1125134716061912
270310340405
200230255300
305350385455
225260285340
162-23-3060162-23-3066162-23-3072162-23-3075
2(7x)1(19x)
1/0(19x)2/0(19x)
0.780.820.860.91
0.850.900.940.98
6 x 146 x 146 x 147 x 14
1.091.141.181.22
562612661730
627684733810
155175200230
135155175200
165190215245
130150175195
162-23-3078� 162-23-3081
162-23-3084� 162-23-3090
3/0(19x)4/0(19x)250(37x)350(37x)
0.960.991.071.16
1.041.061.171.26
9 x 1411 x 1413 x 1418 x 14
1.271.301.411.50
825891
10691254
905100511641425
260290320380
230240260320
280315345415
225255280345
� 162-23-3093� 162-23-3096� 162-23-3099
500(37x)750(61x)
1000(61x)
1.291.481.63
1.391.581.77
16 x 1215 x 10
18 x *(A)
1.721.952.15
166622442808
185324683093
455555645
385470550
495600685
415510585
* - Special Conductor Size (A) Wire O.D. =0.1066"(1) Individual wire size and count may vary. The resulting combination meets the 1/3 or full neutral, size requirement.Visit Okonite's web site www.okonite.com for the most up to date dimensions.
� - Available from Customer Servicecenters.
(2) Full neutral, single phase ampacities are based on ICEA'sS-94-649, Appendix F for 90°C conductor temperature, 20°C ambi-ent temperature, 100% load factor, and earth thermal resistivity ofRHO 90 and modified for jacketed cable.One third neutral ampacities are based on ICEA P-53-426 triplexedor triangular configuration for the same conditions stated above.
THE OKONITE COMPANYRamsey, New Jersey 07446
H\14060236
Okoguard is Okonite's registered trade namefor its exclusive ethylene-propylene rubber(EPR) based, thermosetting compound,whose optimum balance of electrical andphysical properties is unequaled in othersolid dielectrics. Okoguard insulation, withthe distinctive red color and a totally inte-grated EPR system, provides the optimumbalance of electrical and physical propertiesfor long, problem free service.The triple tandem extrusion of the screenswith the insulation provides optimum electri-cal characteristics.An insulation screen of ethylene-propylenerubber is extruded over the insulation. Thebare copper concentric wires are uniformlyspaced around the insulation screen. Theoverall polyethylene jacket provides protec-tion against mechanical damage andcorrosion.Product identification is provided through theuse of three red stripes placed 120° apart inthe black jacket with an NESC lightning bolt.
Okoguard URO-J cables provide maximumcircuit longevity in underground residentialdistribution systems. They can be buried di-rectly or installed in underground ducts orconduits.
Aluminum per ASTMB-609, Class B stranded per B-231.
Extruded semiconduct-ing ethylene-propylene rubber meets orexceeds the requirements of ICEA S-94-649and AEIC CS8.
Extruded Okoguard meets or ex-ceeds the requirements of ICEA S-94-649and AEIC CS8.
Extruded semiconduct-ing ethylene-propylene rubber meets orexceeds the requirements of ICEA S-94-649and AEIC CS8.
Bare copper wires.Black Okolene® with red extruded
stripes, meets or exceeds the requirementsof ICEA S-94-649 for polyethylene jackets.
Triple tandem extruded, all EPR system.
Okoguard cables meet or exceed ICEAand RUS 7CFR 1728.204 standards.
105°C continuous operating temperature140°C emergency rating250°C short circuit rating
Excellent corona resistance.
Low dielectric constant and powerfactor.
Screens are clean stripping.
Exceptional resistance to “treeing”.
Moisture resistant.
Overall jacket provides extended life.
Red extruded stripes
Excellent resistance to most chemicals.
Can be UL Listed as MV90 for use in ac-cordance with Art 328 of the NEC on specialorders.
Can be CSA Listed to C68.5 on specialorders.
Design Options:Additional conductor sizesFilled strandCopper central conductorCopper flat strap concentric neutralProduct identification via colored jacketsSemiconducting jackets
Improved Temperature Rating.Okoguard insulation system has beentested and qualified for operation at105°C continuous and 140°C emergencyoperating temperature.
Minimum installation temperature of-40°C.
Okoguard® URO-J
Aluminum Conductor/105°C Rating100% and 133% Insulation Levels
Conductor-Stranded AluminumStrand Screen-Extruded Semiconducting EPRInsulation-Okoguard EPRInsulation Screen-Extruded Semiconducting EPRConcentric Conductor-BareCopper WiresEncapsulating Jacket-Okolene withthree extruded red ID stripe, andNESC lightning bolt
Okoguard URO-J
Aluminum Conductor/105°C Rating100% Insulation Levels
161-23-4066� 161-23-4069
161-23-4072� 163-23-4072*
161-23-4075
1 (19x)1/0 (1x)
1/0 (19x)1/0 (19x)2/0 (19x)
0.900.890.920.920.98
0.970.971.001.001.05
13 x 1416 x 1416 x 1416 x 1413 x 12
1.211.201.231.231.33
772803832833
1001
872870898899
1117
185210210210240
135150150150175
205235235235270
150170170170200
161-23-4078161-23-4081161-23-4084161-23-4090
3/0 (19x)4/0 (19x)250 (37x)350 (37x)
1.031.091.141.25
1.131.191.241.35
16 x 1213 x 1016 x 1020 x 10
1.401.501.561.73
1157137215461916
1273155017242166
270305335405
200225250300
305345380450
225260285345
160-23-4066160-23-4072160-23-4075160-23-4078
1 (19x)1/0 (19x)2/0 (19x)3/0 (19x)
0.900.940.981.03
0.971.011.051.13
6 x 146 x 147 x 149 x 14
1.211.251.291.37
691741812935
791841912
1051
175200230260
155175200230
190215245280
150175200230
160-23-4081� 162-23-4081*
160-23-4084160-23-4090
4/0 (19x)4/0 (19x)250 (37x)350 (37x)
1.071.071.141.25
1.171.171.241.35
11 x 1411 x 1413 x 1418 x 14
1.401.401.481.59
1010101111521388
1128112913301566
290290315375
245245265325
315315340410
260260285350
160-23-4093� 162-23-4093*
160-23-4096� 162-23-4096*
160-23-4099� 162-23-4099*
500 (37x)500 (37x)750 (61x)750 (61x)
1000 (61x)1000 (61x)
1.371.371.561.561.711.71
1.471.471.701.701.851.85
16 x 1216 x 1215 x 1015 x 10
18 x **(A)18 x **(A)
1.801.802.062.082.232.23
178217842450245030273024
198619882754275435333535
450450550550640640
390390480480565565
495495600600680680
415415515515585585
* These items include filled strand** Special Conductor Size, (A) Wire O.D. =0.1066"(1) Individual wire size and count may vary. The resulting combination meets the 1/3 or full neutral, size requirement.
Visit Okonite's web site www.okonite.com for the most up to date dimensions.
� - Available from Customer Servicecenters.
(2) Full neutral, single phase ampacities are based on 90°C or 105°Cconductor temperature, 20°C ambient temperature, 100% load fac-tor, and earth thermal resistivity of RHO 90.One third neutral ampacities are based on ICEA P-53-426 triplexedor triangular configuration for the same conditions stated above.
Nomina
l O.D
. (in.
)
Condu
ctor Size
AWG\kc
mil
Nomina
l Dia.
over
Insu
lation
Scree
n(in
.)
Coppe
r Neutra
l No.
x AWG
(1)
Catalo
gNum
ber
Aprox
. Ship
Weig
ht
lbs./1
000’
Aprox
. Net
Weig
ht
lbs./1
000’
105°
Ampa
city Duc
t (2)
105°
Ampa
city Dire
ctBur
ial(2
)
90°A
mpa
city Duc
t (2)
90° Am
pacit
y Direct
Burial
(2)
Nomina
l Dia.
over
Insu
lation
(in.)
Okoguard URO-J
Aluminum Conductor/105°C Rating133% Insulation Levels
161-23-5066161-23-5072161-23-5075
1 (19x)1/0 (19x)2/0 (19x)
1.021.061.10
1.121.161.20
13 x 1416 x 1413 x 12
1.361.401.47
93110221175
104711381353
185210240
135150175
205235270
150170200
161-23-5078161-23-5081161-23-5084161-23-5090
3/0 (19x)4/0 (19x)250 (37x)350 (37x)
1.151.211.271.37
1.251.311.371.47
16 x 1213 x 1016 x 1020 x 10
1.521.691.741.85
1308160017822099
2503181920322349
270305335405
200225250300
305345380450
225260285345
160-23-5066160-23-5072160-23-5075160-23-5078
1 (19x)1/0 (19x)2/0 (19x)3/0 (19x)
1.021.061.101.15
1.121.161.201.25
6 x 146 x 147 x 149 x 14
1.361.401.441.49
850906983
1083
966102210991261
175200230260
155175200230
190215245280
150175200230
160-23-5081160-23-5084160-23-5090
4/0 (19x)250 (37x)350 (37x)
1.211.271.37
1.311.371.47
11 x 1413 x 1418 x 14
1.551.601.77
120013121631
137814901881
290315375
245265325
315340410
260285350
160-23-5093160-23-5096160-23-5099
500 (37x)750 (61x)
1000 (61x)
1.501.691.84
1.601.831.98
16 x 1215 x 10
18 x **(A)
1.932.202.35
202527223265
227531223771
450550640
390480565
495600680
415515585
(1) Individual wire size and count may vary. The resulting combination meets the 1/3 or full neutral, size requirement.** Special Conductor Size, (A) Wire O.D. =0.1066"Visit Okonite's web site www.okonite.com for the most up to date dimensions.
Nomina
l O.D
. (in.
)
Condu
ctor Size
AWG\kc
mil
Nomina
l Dia.
over
Insu
lation
(in.)
Numbe
r ofStra
nds
Catalo
gNum
ber
Appro
x.Ship
Weig
ht
lbs./1
000’
Appro
x.Net
Weig
ht
lbs./1
000’
105°
Ampa
city Duc
t (2)
105°
Ampa
city Dire
ctBur
ial(2
)
90°A
mpa
city Duc
t (2)
90° Am
pacit
y Direct
Burial
(2)
Nomina
l Dia.
over
Insu
lation
Scree
n(in
.)
Coppe
r Neutra
l No.
x AWG
(1)
(2) Full neutral, single phase ampacities are based on 90°C or 105°Cconductor temperature, 20°C ambient temperature, 100% load fac-tor, and earth thermal resistivity of RHO 90.One third neutral ampacities are based on ICEA P-53-426 triplexedor triangular configuration for the same conditions stated above.
E\14020239
THE OKONITE COMPANYRamsey, New Jersey 07446
Okoguard is Okonite's registered trade namefor its exclusive ethylene-propylene rubber(EPR) based, thermosetting compound,whose optimum balance of electrical andphysical properties is unequaled in othersolid dielectrics. Okoguard insulation, withthe distinctive red color and a totally inte-grated EPR system, provides the optimumbalance of electrical and physical propertiesfor long, problem free service.The triple tandem extrusion of the screenswith the insulation provides optimum electri-cal characteristics.An insulation screen of ethylene-propylenerubber is extruded over the insulation. Thebare copper concentric wires are uniformlyspaced around the insulation screen. Theoverall polyethylene jacket provides protec-tion against mechanical damage andcorrosion.Product identification is provided through theuse of three red stripes placed 120° apart inthe black jacket, with an NESC lightning bolt.
Okoguard URO-J cables provide maximumcircuit longevity in underground residentialdistribution systems. They can be buried di-rectly or installed in underground ducts orconduits.
Aluminum per ASTMB-609, Class B stranded per B-231.
Extruded semiconduct-ing ethylene-propylene rubber meets orexceeds the requirements of ICEA S-94-649and AEIC CS8.
Extruded Okoguard meets or ex-ceeds the requirements of ICEA S-94-649and AEIC CS8.
Extruded semiconduct-ing ethylene-propylene rubber meets orexceeds the requirements of ICEA S-94-649and AEIC CS8.
Bare copper wires.Black Okolene with red extruded
stripes meets or exceeds the requirements ofICEA S-94-649 for polyethylene jackets.
Triple tandem extruded, all EPR system.
Okoguard cables meet or exceed ICEAand RUS 7CFR 1728.204 standards.
105°C continuous operating temperature140°C emergency rating250°C short circuit rating
Excellent corona resistance.
Low dielectric constant and powerfactor.
Screens are clean stripping.
Exceptional resistance to “treeing”.
Moisture resistant.
Overall jacket provides extended life.
Excellent resistance to most chemicals.
Can be UL listed to MV90 for use in ac-cordance with Article 328 of the NEC onspecial orders.
Can be CSA listed to C68.5 on specialorders
Design Options:Additional conductor sizesFilled strandCopper central conductorCopper flat strap concentric neutralProduct identification via coloredjacketsSemiconducting jackets
Improved Temperature Rating.Okoguard insulation system has beentested and qualified for operation at105°C continuous and 140°C emergencyoperating temperature. Appropriate jacketshould be selected when cable is to beoperated at these higher temperatures.
Minimum installation temperature of-40°C.
Okoguard® URO-J
Aluminum Conductor/105°C Rating100% and 133% Insulation Levels
Conductor-Stranded AluminumStrand Screen- ExtrudedSemiconducting EPRInsulation-Okoguard EPRInsulation Screen- ExtrudedSemiconducting EPRConcentric Conductor-Bare CopperWiresEncapsulating Jacket-Okolene withthree extruded red ID stripes andNESC lightning bolt
Okoguard URO-J
Aluminum Conductor/105°C Rating100% Insulation Level
� 161-23-6072� 163-23-6072*
161-23-6075161-23-6078
1/0 (19x)1/0 (19x)2/0 (19x)3/0 (19x)
1.101.101.151.20
1.201.201.251.30
16 x 1416 x 1413 x 1216 x 12
1.441.441.521.57
1061106312381374
1179118114161552
210210240270
150150175200
235235270305
170170200225
161-23-6081161-23-6084161-23-6090
4/0 (19x)250 (37x)350 (37x)
1.261.321.42
1.361.421.52
13 x 1016 x 1020 x 10
1.741.791.90
167118562177
192121062525
305335405
225250300
345380450
260285345
160-23-6072160-23-6075160-23-6078
1/0 (19x)2/0 (19x)3/0 (19x)
1.111.151.20
1.211.251.30
6 x 147 x 149 x 14
1.451.491.54
96610451148
108212231326
200230260
175200230
215245280
175200230
160-23-6081160-23-6084160-23-6090
4/0 (19x)250 (37x)350 (37x)
1.261.321.42
1.361.421.52
11 x 1413 x 1418 x 14
1.601.721.82
126714511707
144517011957
290315375
245265325
315340410
260285350
160-23-6093160-23-6096160-23-6099
500 (37x)750 (61x)
1000 (61x)
1.551.741.89
1.681.882.03
16 x 1215 x 10
18 x **(A)
2.022.252.40
216728173366
251533233872
450550640
390480565
495600680
415515585
* These items include filled strand.** Special Conductor Size, (A) wire OD-0.1066"
Visit Okonite's web site www.okonite.com for the most up to date dimensions.
� - Available from Customer Servicecenters.
(1) Individual wire size and count may vary. The resulting combinationmeets the 1/3 or full neutral, size requirement.
(2) Full neutral, single phase ampacities are based on 90°C or 105°Cconductor temperature, 20°C ambient temperature, 100% load factor,and earth thermal resistivity of RHO 90.One third neutral ampacities are based on ICEA P-53-426 triplexed ortriangular configuration for the same conditions stated above.
Okoguard URO-J
Aluminum Conductor/105°C Rating133% Insulation Level
161-23-7072161-23-7075161-23-7078
1/0 (19x)2/0 (19x)3/0 (19x)
1.261.311.36
1.361.411.46
16 x 1413 x 1216 x 12
1.601.741.79
128515201666
146317701916
205235265
150170200
230265300
175200230
161-23-7081161-23-7084161-23-7090
4/0 (19x)250 (37x)350 (37x)
1.421.471.58
1.521.571.71
13 x 1016 x 1020 x 10
1.891.952.09
190921022498
215923522846
305335400
225245295
340375445
260290350
160-23-7072160-23-7075160-23-7078
1/0 (19x)2/0 (19x)3/0 (19x)
1.261.311.36
1.361.411.46
6 x 148 x 149 x 14
1.601.711.76
116913231434
134715731684
200225255
175200230
210240275
175205235
160-23-7081160-23-7084160-23-7090
4/0 (19x)250 (37x)350 (37x)
1.421.471.58
1.521.571.71
11 x 1413 x 1418 x 14
1.821.872.01
156416892019
181419392367
280315375
245265325
310340405
265290350
160-23-7093160-23-7096160-23-7099
500 (37x)750 (61x)
1000 (61x)
1.701.902.05
1.842.032.18
16 x 1215 x 10
18 x **(A)
2.182.412.56
244631263696
284636324202
450550640
390480565
490595680
420515600
** Special Conductor Size, (A) wire OD-0.1066"
Visit Okonite's web site www.okonite.com for the most up to date dimensions.
(1) Individual wire size and count may vary. The resulting combinationmeets the 1/3 or full neutral, size requirement.
(2) Full neutral, single phase ampacities are based on 90°C or 105°Cconductor temperature, 20°C ambient temperature, 100% load factor,and earth thermal resistivity of RHO 90.One third neutral ampacities are based on ICEA P-53-426 triplexed ortriangular configuration for the same conditions stated above.
D\14020240
THE OKONITE COMPANYRamsey, New Jersey 07446
Composite InsulationOkoguard-Okolon TS-CPE is Okonite’s tradename for its composite insulation systemconsisting of a layer of EPR and coveredwith a chlorinated polyethylene (CPE)thermoset compound.
The advantages of Okoguard EPR, with aproven track record of over 40 years as amedium voltage insulation, are now offeredin low voltage cables. Okolon TS-CPE isOkonite's trade name for its chlorinated poly-ethylene (CPE) thermoset compound.
ApplicationsOkoguard-Okolon TS-CPE 600 Volt Powerand Control Cables are recommended foruse in all low voltage circuits where continu-ity of service is the prime consideration.These cables may be installed in wet or drylocations, indoors or outdoors, in raceways,underground ducts, directly buried in theearth, or lashed to a messenger for aerial in-stallation. These cables may also be in-stalled in cable tray (size 1/0 AWG and largerper NEC 392.2).
SpecificationsConductor: Uncoated soft copper per ASTMB-3. Solid per ASTM B-3. Sizes smaller than#8 are compress stranded per ASTM B-8.Sizes #8 and larger are compact strandedper ASTM B-496.
Insulation: Meets or exceeds all require-ments of ICEA S-95-658, NEMA WC-70 andUL Standards 44 and 854.
Listed by Underwriters Laboratories, Inc. asType RHH or RHW-2 or USE-2, VW-1. Sizes1/0 AWG and larger are also marked sunlightresistant, for use in cable tray.
Listed by CSA as RW-90, -40C, FT1 (1/0and larger: FT4), sunlight resistant.
Product Features• Sizes 1/0 AWG and larger pass the Ver-tical Tray Flame Test requirements of UL1581 for use in cable tray.
• Passes the IEEE 383-1974 VerticalTray Flame Test. (sizes #6 AWG andlarger)
• Passes the IEEE 1202 Vertical TrayFlame Test. (sizes 1/0 AWG & larger)
• Extreme heat resistance;90°C continuous rating, wet or dry130°C emergency overload rating250°C short circuit rating
• Exceptional resistance to deformationat high temperature.
• Stable electrical properties.
• Low SIC and power factor.
• Low moisture absorption.
• Mechanically rugged.
• Resistant to weather, most oils, acidsand alkalies.
• More flexible, easier to install and termi-nate than XLPE insulation.
• UL and CSA Listed.
Okoguard-Okolon® TS-CPE Type RHHor RHW-2 or USE-2, VW-1, FT-4, CSA RW-90600V Power and ControlCopper Conductor/90°C Wet or DryFor Cable Tray Use-Sunlight Resistant-For Direct Burial
Product DataSection 3: Sheet 1
A Uncoated, Copper ConductorB Composite Okoguard/Okolon
TS-CPE Insulation
Composite InsulationThickness (mils)
Conductor(AWG/kcmil) Okoguard
OkolonTS-CPE
14-9 30 15
8 45 15
6-2 45 30
1-4/0 55 45
250-500 65 65
750-1000 80 65
ULR
B
A
OK
ON
ITE
51/
0A
WG
CU
OK
OG
UA
RD
EP
TS
-CP
E(U
L)C
SA
112-24-2061� 112-24-2071
112-24-2091
141412
171
454545
1.141.141.14
0.160.170.18
4.064.574.57
232532
283037
151520
151520
242430
� 112-24-2101112-24-2121
� 112-24-2131
121010
717
454545
1.141.141.14
0.190.200.21
4.835.085.33
344649
395154
203030
203030
304242
112-24-2171� 112-24-2191� 112-24-2221
986
1977
456075
1.141.521.91
0.230.270.33
5.846.868.38
5875
119
6382
130
305575
305065
485575
� 112-24-2251� 112-24-2311
112-24-2331
421
77
19
7575
100
1.911.912.54
0.380.430.52
9.7511.0013.16
173257340
184280372
95130150
85115130
97130156
� 112-24-2351� 112-24-2371
112-24-2391
1/02/03/0
191919
100100100
2.542.542.54
0.560.600.64
14.1015.1416.33
414507622
446539654
170195225
150175200
179204242
� 112-24-2411� 112-24-2431� 112-24-2471
4/0250350
193737
100130130
2.543.303.30
0.700.800.89
17.6820.3222.61
766938
1265
805993
1320
260290350
230255310
278317384
� 112-24-2531� 112-24-2591� 112-24-2651
500750
1000
376161
130145145
3.303.683.68
1.011.211.36
25.6530.7334.54
175025903391
182726903568
430535615
380475545
477598689
Visit Okonite's web site, www.okonite.com, for the most up to date dimensions.
� Available from our Customer Service Centers. are based on Table 310.16 of the National Electrical Code forthese 90°C rated conductors at an ambient temperature of 30°C. The 75°Cwet column is provided for additional information.
The ampacities shown apply to open runs of cable, installation in any approvedraceway, direct burial in the earth, or as aerial cable on a messenger. Deratingfor more than three current carrying conductors within a raceway is in accor-dance with NEC Sectiion 310.15.B.2.
Based on three (3) conductors in a single enclosed or exposed conduit. Ca-pacities based on 40°C air ambient using ICEA methods. For 30°C ambientmultiply values by 1.10; for 50°C multiply by .90. For other ambients or installa-tion conditions refer to Engineering Data Book EHB.
For ampacities in cable tray, see NEC Section 392.11.B.
B\11100301
Okoguard-Okolon TS-CPE Type RHH orRHW-2 or USE-2, VW-1, FT-4, CSA RW-90Copper Conductor/90°C Wet or Dry
To order a color other than black, change the last digit of thecatalog number as follows:
White 2 Orange 5
Red 3 Blue 6
Green 4 Yellow 7
Example: To order #14/Sol - Red, the catalog number would be112-24-2063.
ULR
Ramsey, New Jersey 07446THE OKONITE COMPANY
Composite InsulationOkoguard-Okolon® TS-CPE is Okonite’strade name for its composite insulationsystem consisting of a layer of EPR andcovered with a chlorinated polyethylene(CPE) thermoset compound. The combi-nation of the two materials provides adielectric which has excellent resistanceto heat, mechanical abuse, flame,weathering, most oils, acids and al-kalies.The advantages of Okoguard EPR, witha proven track record of over 40 yearsas a medium voltage insulation, are nowoffered in low voltage cables. OkolonTS-CPE is Okonite's trade name for itschlorinated polyethylene (CPE)thermoset compound.
ApplicationsOkoguard-Okolon TS-CPE 2000 voltpower cables are recommended for usein all low voltage circuits where continu-ity of service is the prime consideration.They can be installed in wet or dry loca-tions, indoors or outdoors in conduit,underground ducts, approved raceways.These cables may also be installed incable tray (size 1/0 AWG kcmil andlarger per NEC 392.3).
SpecificationsConductors: Uncoated soft copper perASTM B-3. Solid per ASTM B-3. Sizessmaller than #8 are compress strandedper ASTM B-8. Sizes #8 and larger arecompact stranded per ASTM B-496.Composite Insulation: Meets or ex-ceeds all requirements of ICEAS-95-658, NEMA WC-70 and UL Stan-dard 44.Listed by Underwriters Laboratories, Inc.as Type RHH or RHW-2, VW-1. Sizes1/0 AWG and larger are also markedsunlight resistant, for use in cable tray.All sizes meet FT-1. Sizes 1/0 andlarger meet FT-4.
Product Features• Sizes 1/0 AWG and larger pass theVertical Tray Flame Test require-ments of UL 1581 for use in cabletray.• Passes the IEEE 383-1974 VerticalTray Flame Test (size #8 AWG andlarger).• Passes the IEEE 1202 Vertical TrayFlame Test (sizes 1/0 AWG andlarger).• Extreme heat resistance90°C continuous rating, wet or dry130°C emergency overload rating250°C short circuit rating• Exceptional resistance to deforma-tion at high temperature.• Stable electrical properties.• Low SIC and power factor.• Low moisture absorption.• Mechanically rugged.• Resistant to weather, most oils, ac-ids and alkalies.• Smaller diameter than RHW jack-eted cables.• More flexible, easier to install, ter-minate or splice than XLPEinsulation.• UL Listed.• OSHA acceptable.• UL E1138.• FT-1 all sizes.• FT-4 - 1/0 and larger.
Okoguard-Okolon® TS-CPEType RHH or RHW-2, VW-1, FT-42kV Power CableCopper Conductors/90°C Wet or DryFor Cable Tray Use - Sunlight Resistant
Product DataSection 3: Sheet 10
A Uncoated Copper ConductorB Composite Okoguard—Okolon
TS-CPE Insulation
ULR
Composite InsulationThickness (mils)
Conductor(AWG/kcmil) Okoguard Okolon
TS-CPE
14-109
8-21-4/0
250-500750-1000
455555657590
151530456565
B
A
OK
OG
UA
RD
EP
TS
-CP
E(U
L)
RH
HO
RR
HW
-2V
W-1
113-24-2061� 113-24-2071
113-24-2091
141412
171
606060
1.521.521.52
0.190.200.21
4.835.085.33
283038
333543
151520
151520
242430
� 113-24-2101113-24-2121
� 113-24-2131
121010
717
606060
1.521.521.52
0.220.230.24
5.595.846.10
405255
455760
203030
203030
304242
113-24-2171� 113-24-2191� 113-24-2221
986
1977
708585
1.792.162.16
0.280.320.35
7.118.138.89
7090
126
75101137
305575
305065
485575
� 113-24-2251� 113-24-2311
113-24-2331
421
77
19
8585
110
2.162.162.79
0.400.450.54
10.2611.4313.72
180265348
191278367
95130150
85115130
97130156
� 113-24-2351� 113-24-2371
113-24-2391
1/02/03/0
191919
110110110
2.792.792.79
0.570.610.66
14.4815.4916.76
424517633
442537657
170195225
150175200
179204242
� 113-24-2411� 113-24-2431� 113-24-2471
4/0250350
193737
110140140
2.793.563.56
0.710.830.92
18.0321.0823.37
777957
1286
81310041355
260290350
230255310
278317384
� 113-24-2531� 113-24-2591
113-24-2651
500750
1000
376161
140155155
3.563.943.94
1.041.241.38
26.4231.5035.05
177326183423
191528053674
430535615
380475545
477598689
Visit Okonite's web site, www.okonite.com, for the most up to date dimensions.
� Authorized stock item. Available from our Customer Service Centers. Ampacities
(1) Ampacities are based on Table 310.15(B)(16) of the National ElectricalCode for these 90°C rated conductors at an ambient temperature of 30°C. The75°C wet column is provided for additional information.
The ampacities shown apply to open runs of cable, installation in any approvedraceway, direct burial in the earth, or as aerial cable on a messenger. Deratingfor more than three current carrying conductors within a raceway is in accor-dance with NEC 310.15(B)(3).
(2) Based on three (3) conductors in a single enclosed or exposed conduit. Ca-pacities based on 40°C air ambient using ICEA method. For 30°C ambientmultiply values by 110; for 50°C multiply by 90. For other ambients or installa-tion conditions refer to Okonite’s Engineering Data Book EHB.
For ampacities in cable tray see NEC Section 392.80.
C/15070310
Okoguard-Okolon TS-CPEType RHH or RHW-2, VW-1, FT-42kV Power CableCopper Conductor/90°C Wet or DryFor Cable Tray Use - Sunlight Resistant
Product DataSection 3: Sheet 10
To order a color other than black, change the last digit of thecatalog number as follows:
White 2 Orange 5
Red 3 Blue 6
Green 4 Yellow 7
Example: To order #14 - Red, the catalog number would be113-24-2073.
ULR
Catalo
gNum
ber
Approx.
ShipW
eight
lbs./
1000
’
ICEA
Ampac
ity(2
)
Number
of Strands
Approx.
O.D. -
mm
Composit
e Insu
latio
n
Thicknes
s - mm
75°C
Wet
(1)
NECAm
pacity
Composit
e Insu
latio
n
Thicknes
s - mils
Approx.
O.D. -
Inch
es
Approx.
NetW
eight
lbs./
1000
’
Conductor Size
AWG
or kcm
il
90°C
Wet
(1)
NECAm
pacity
Ramsey, New Jersey 07446THE OKONITE COMPANY
InsulationX-Olene® is Okonite's trade name for its chemi-cally cross-linked polyethylene, with highdielectric strength.Color CodingConductors 6 AWG and smaller are color codedusing base colors and tracers in accordance withthe Conductor Identification Table on the back ofthis Data Sheet. Sizes 4 AWG and larger areprinted number/color coded.Assembly and CoveringsThe individual conductors are cabled togetherwith non-hygroscopic fillers and a binder tapeoverall. The C-L-X sheath exceeds the groundingconductor requirements of Table 250.122 of theNEC and UL 1569. A bare stranded coppergrounding conductor(s), located in the outer inter-stices, is provided for grounding. The impervious,continuous, welded, corrugated aluminum C-L-Xsheath provides complete protection againstmoisture, liquids and gases and has excellentmechanical strength. For direct burial in theground, embedment in concrete, or for areas sub-jected to corrosive atmospheres, the C-L-Xsheath is protected with a low temperature blackOkoseal® (PVC) jacket.ApplicationsC-L-X Type MC-HL cables with the impervious,continuous, corrugated aluminum sheath are rec-ommended as an economical alternate to a wirein conduit system.They are authorized for use on services, feedersand branch circuits for power, lighting, control andsignaling circuits in accordance with Article 330and 725 of the NEC.C-L-X Type MC-HL cables may be installed in-doors or outdoors, in wet or dry locations, as openruns of cable secured to supports spaced notmore than six feet apart, in cable tray, as aerial ca-ble on a messenger, in any approved raceway,direct burial, or encased in concrete. C-L-X typeMC-HL cables are also approved for Classes I, IIand III, Division 1 and 2 and Class I, Zones 1 and2 hazardous locations per NEC Articles 501, 502,503 and 505; in Zone 1, Zone 2, Class II Div 2,Class III Div 1 and Class III Div 2 per CEC.SpecificationsConductors: Uncoated soft copper perASTM B-3. Sizes smaller than #8 are com-press stranded per ASTM B-8. Sizes #8 andlarger are compact stranded per ASTMB-496.Insulation: X-Olene per ICEA S-95-658/NEMA WC70 and UL 44, Listed UL TypeXHHW-2. Meets MIL-DTL-1377H, section4.8.4.1.2 cold bend at -66°C and ASTM D746-04brittle point at -76°C.
Conductor Identification: Control Sizes,#9 AWG and smaller, color coded insula-tion. Power Sizes, #8 AWG and larger,black with printed words of number andcolor.Grounding Conductor(s): One or threebare soft copper per ASTM B-3. Stranded inaccordance with UL 1581. Meets or exceedsrequirements of NEC Table 250.122.Sheath: Close fitting, impervious, continu-ous, welded, corrugated aluminum C-L-Xper UL 1569. Exceeds grounding conductorrequirements of NEC Table 250.122.Jacket: Black Okoseal (PVC) per UL1569.Meets ASTM D746-04 brittle point at -40°C.Product Features• UL Listed as Type MC-HL cable per E38916• UL Listed for cable tray use, direct burialand sunlight resistant.• UL 1309 (CWCMC) listed & UL classified inaccord with IEEE 1580 as Marine ShipboardCable rated 600/1000 volts.• CSA listed as RA90, FT4, HL and LTGG(-40°C).• Passes the IEEE 383-1974 and IEEE 1202vertical tray flame tests.• Passes the 210,000 BTU ICEA T-29-520Vertical Tray Flame Test.• Complete pre-packaged, factory-tested wir-ing system; color coded.• C-L-X cables are quality control inspected tomeet or exceed applicable UL standards.• 90°C continuous operating temperature inall types of installations.• 130°C emergency rating.• 250°C short circuit rating.• Good EMI shielding characteristics.• Impervious, continuous metallic sheath ex-cludes moisture, gases and liquids.• Lower installed system cost than conduit orEMT systems.• Provides excellent grounding safety.• Excellent compression and impact resis-tance.• Continuous long lengths.• Installation temperature of -40°C or °F.• Complies with NEC Articles 501, 502 and503 for hazardous locations.• American Bureau of Shipping Typeapproved as CWCMC Type MC-HL.• Three symmetrical grounding conductorsfor PWM/VFD and other modern ACdrive/motor applications.• CSA Type RA90-HL complies with CECZone 1, Zone 2, Class II Div 2, Class III Div 1and Class III Div 2 Hazardous Locations.
C-L-X® Type MC-HL (XHHW-2)600V Power MC-HL Cable—Aluminum Sheath600/1000V Marine CableMultiple Copper Conductors/90°C Wet or Dry RatingFor Cable Tray Use - Sunlight Resistant - For Direct Burial
A Bare, Stranded Copper ConductorsB X-Olene Insulation �Color Coded for
IdentificationC Bare, Stranded Copper Grounding
Conductor(s)D Non-Hygroscopic Fillers, as neces-
saryE Binder TapeF Impervious, Continuous, Welded Cor-
rugated, Aluminum C-L-X SheathG Black Okoseal Jacket
ULR
Product DataSection 4: Sheet 1
A
B
E
F
C
D
G
AW
GC
UG
ND
CL
X(U
L)X
HH
W-2
SU
N
C-L-X Type MC-HL (XHHW-2)600V Power MC-HL Cable—Aluminum Sheath600/1000V Marine CableMultiple Copper Conductors/90°C Wet or Dry RatingFor Cable Tray Use - Sunlight Resistant - For Direct Burial
� 546-31-3403� 546-31-3404
14(7X)(2.08mm2)
34 30
3 #183 #18
0.330.37
8.49.3
0.530.58
13.514.7
5050
1.271.27
0.640.69
16.317.5
0.320.37
160222
190261
1515
1515
� 546-31-3453� 546-31-3454
12(7X)(3.31mm2)
34 30
3 #163 #16
0.370.45
9.311.4
0.580.67
14.716.9
5050
1.271.27
0.690.78
17.519.7
0.370.47
239286
278320
2020
2020
� 546-31-3503� 546-31-3504
10(7X)(5.26mm2)
34 30
3 #143 #14
0.410.45
10.411.4
0.620.67
15.816.9
5050
1.271.27
0.730.78
18.619.7
0.420.47
300348
380428
3030
3028
� 571-31-3190� 571-31-3263
8(7X)(8.36mm2)
34 45
3#1410
0.500.58
12.714.7
0.710.80
18.020.3
5050
1.271.27
0.810.90
20.622.9
0.520.64
385465
420495
5544
5040
� 571-31-3191� 571-31-3270
6(7X)(13.3mm2)
34 45
3#128
0.580.66
14.716.8
0.800.89
20.322.5
5050
1.271.27
0.900.99
22.925.1
0.640.77
525630
595685
7560
6552
� 571-31-3200� 571-31-3272
4(7X)(21.2mm2)
34 45
3#128
0.680.77
17.319.6
0.890.97
22.524.7
5050
1.271.27
0.991.08
25.127.5
0.770.92
704845
820930
9576
8568
� 571-31-3204� 571-31-3276
2(7X)(33.6mm2)
34 45
3#106
0.800.92
20.323.4
1.021.15
25.929.2
5050
1.271.27
1.131.26
28.732.0
1.001.25
9951245
10501370
130104
11592
571-31-3208571-31-3280
1(19X)(42.4mm2)
34 55
3#106
0.921.04
23.426.4
1.151.29
29.232.8
5050
1.271.27
1.261.40
32.035.6
1.251.54
11001500
11811620
150120
130104
� 571-31-3213571-31-3285
1/0(19X)(53.5mm2)
34 55
3#106
1.001.12
25.528.4
1.241.37
31.434.9
5050
1.271.27
1.341.48
34.037.6
1.411.72
14701830
15601975
170136
150120
� 571-31-3216� 571-31-3289
2/0(19X)(67.4mm2)
34 55
3#106
1.091.23
27.731.2
1.341.51
34.038.5
5060
1.271.52
1.441.64
36.641.7
1.632.11
17702310
20202545
195156
175140
� 571-31-3224� 571-31-3296
4/0(19X)(107mm2)
34 55
3#84
1.331.49
33.837.8
1.601.78
40.645.2
6060
1.521.52
1.731.91
44.048.6
——
26753430
28803710
260208
230184
� 571-31-3228571-31-3300
250(37X)(127mm2)
34 65
3#84
1.481.64
37.641.6
1.741.96
44.249.7
6060
1.521.52
1.872.09
47.553.0
——
31404070
34204330
290232
255185
� 571-31-3236� 571-31-3308
350(37X)(177mm2)
34 65
3#73
1.661.89
42.248.0
1.962.19
49.755.6
6075
1.521.90
2.092.35
53.059.8
——
42105440
43006000
350280
310248
� 571-31-3244� 571-31-3316
500(37X)(253mm2)
34 65
3#62
1.942.14
59.354.4
2.282.49
57.963.2
7575
1.901.90
2.442.65
62.067.4
——
59307570
64208120
430344
380304
� 571-31-3248571-31-3320
750(61X)(380mm2)
34 80
3#51
2.372.61
60.266.2
2.753.03
69.876.9
7585
1.902.16
2.923.21
74.181.6
——
870011250
940012190
535428
475380
571-31-3252571-31-3324
1000(61X)(507mm2)
34 80
1/01/0
2.673.07
67.778.0
3.113.63
79.092.1
8585
2.162.16
3.303.81
83.896.8
——
1141015110
1243017510
615492
545436
Visit Okonite's web site, www.okonite.com for the most up to date dimensions.
Approx.
NetW
eight
lbs./
1000
’
Approx.
ShipW
eight
lbs./
1000
’
Jack
etThick
ness - m
m
Conductor Size
AWG
Number
of Conductors
Insu
latio
nThick
ness - m
ils
Groundin
gConduct
or(s) AW
G
CoreO.D
. -In
ches
CoreO.D
. -m
m
Catalo
gNum
ber
Cross
-Sec
tional
Area (s
q. In.)
�
Jack
etThick
ness - m
ils
Approx.
O.D. -
Inch
es
Approx.
O.D. -
mm
90°C
Wet
or Dry
NECAm
pacity
75°C
Wet
NECAm
pacity
C-L-X
O.D. -
Inch
es
C-L-X
O.D. -
mm
ULR
Product DataSection 4: Sheet 1
� Authorized Stock Item - Available from our Service Centers.
Copper or Bronze C-L-X is available on special order.
JacketsOptional jacket types available - consult local sales office.
� Cross-sectional area for calculation of cable tray fill in accordance withNEC Section 392.22.
(1) Ampacities
Ampacities are based on Table 310.15(B)(16) of the National Electrical Code forXHHW-2 conductors rated 90°C, in a multi-conductor cable, at an ambient tem-perature of 30°C (86F). The 75°C column is provided for additional information.
The ampacities shown apply to open runs of cable, installation in any approvedraceway, direct burial in the earth, or as aerial cable on a messenger. Deratingfor more than three current carrying conductors within the cable is in accor-dance with NEC Section 310.15(B)(3)(a).
The ampacities shown also apply to cables installed in cable tray in accordancewith NEC Section 392.80.
C-L-X Type MC-HL (XHHW-2)600V Power MC-HL Cable—Aluminum Sheath600/1000V Marine CableMultiple Copper Conductors/90°C Wet or Dry RatingFor Cable Tray Use - Sunlight Resistant - For Direct Burial
600V Composite Power and Control Cable — Aluminum SheathOkoseal Jacket: 50 mils (1.27mm)
� 546-31-3984� 571-31-3657� 571-31-3667� 571-31-3677
3X103X83X63X4
30454545
4X124X124X124X12
30303030
101088
0.750.890.930.97
19.022.623.624.7
0.860.991.031.08
21.925.126.227.5
0.580.770.830.92
425530655810
460585720895
30557595
30506585
Visit Okonite's web site, www.okonite.com for the most up to date dimensions.
Insu
latio
nThick
ness - m
ils
PowerConduct
ors
Number
x Size
Insu
latio
nThick
ness - m
ils
Groundin
gConduct
or (AW
G)
Catalo
gNum
ber
Control C
onductors
Number
XSize
Cable
O.D. -
Inch
es
Cable
O.D. -
mm
C-L-X
O.D. -
Inch
es
C-L-X
O.D. -
mm
Approx.
NetW
eight
lbs./
1000
’
Approx.
ShipW
eight
lbs./
1000
’
Cross
-Sec
tional
Area (s
q. In.)
�
90°C
Wet
or Dry
NECAm
pacity
(1)
75°C
Wet
NECAm
pacity
ULR
Product DataSection 4: Sheet 1
F/15030401
Conductor Color Coding Sequence
ConductorNumber
Base Color
1234
BlackRedBlue
Orange
Sizes 14, 12 & 10 AWG:Color Coding per ICEA Method 1, E-2 color sequence.
Sizes 8 AWG and larger:Surface Printing of Numbers and colordescriptions per ICEA Method , E-2 color sequence
Special Order: Any or all of the following conductors may be added when specifically re-quested by the customer to meet his specific application requirements. These conductorcodings comply with UL and NEC requirements.
Purpose Base Color Tracer Color
Equipment Grounding UninsulatedGreenGreen 1 or more continuous
yellow stripes
Grounded WhiteWhiteWhiteWhiteWhiteWhiteWhite
Black continuous stripeRed continuous stripeBlue continuous stripe
Orange continuous stripeBrown continuous stripe
Numeric Printing
C-L-X Type MC-HL (XHHW-2)600V Power MC-HL Cable—Aluminum Sheath600/1000V Marine CableMultiple Copper Conductors/90°C Wet or Dry RatingFor Cable Tray Use - Sunlight Resistant - For Direct Burial
ULR
Product DataSection 4: Sheet 1
THE OKONITE COMPANYRamsey, New Jersey 07446
A
B
E
F
C
D
G
InsulationX-Olene® is Okonite's trade name for itschemically cross-linked polyethylene, withhigh dielectric strength.
Color CodingConductors 6 AWG and smaller are colorcoded black, red, blue, orange. Power con-ductors #4 AWG and larger are printednumber/color coded. Control conductors arecolor coded black, red, blue, yellow. Whenthe control conductors are within one stan-dard AWG size of the power conductors, thecontrol conductors have an additional tracerto facilitate identification.
Assembly and CoveringsThe individual conductors are cabled to-gether with non-hygroscopic fillers, barecopper equipment grounding conductor,where indicated, and a binder tape overall.The C-L-X sheath exceeds the groundingconductor requirements of Table 250.122 ofthe NEC and UL 1569. The impervious, con-tinuous, welded, corrugated aluminumC-L-X sheath provides complete protectionagainst moisture, liquids and gases and hasexcellent mechanical strength. For directburial in the ground, embedment in concrete,or for areas subjected to corrosive atmos-pheres, the C-L-X sheath is protected with alow temperature black Okoseal® (PVC)jacket.
ApplicationsC-L-X Type MC cables with the impervious,continuous, corrugated aluminum sheath arerecommended as an economical alternate toa wire in conduit system.They are authorized for use on feeders andbranch circuits for power, lighting, controland signaling circuits in accordance with Arti-cle 330 and 725 of the NEC.C-L-X Type MC cables may be installed in-doors or outdoors, in wet or dry locations, asopen runs of cable secured to supportsspaced not more than six feet apart, in cabletray, as aerial cable on a messenger, in anyapproved raceway, direct burial, or encasedin concrete. C-L-X type MC cables are alsoapproved for use in Class I & II, Division 2,Class III, Divisions 1 and 2 and Class I,Zone 2 hazardous locations per NEC Articles501, 502, 503 and 505; in Zone 2, Class IIDiv 2, Class III Div 1 and Class III Div 2 perCEC.
SpecificationsConductors: Uncoated soft copper perASTM B-3. Sizes smaller than #8 are com-pressed stranded per ASTM B-8. Sizes #8and larger are compact stranded per ASTMB-496.
Insulation: X-Olene per ICEA S-95-658/NEMA WC-70, ICEA S-73-532/NEMAWC57, and UL 44, Listed UL TypeXHHW-2. Meets MIL-DTL-1377H, section4.8.4.1.2 cold bond at -66°C and ASTMD746-04 brittle point at -76°C.Conductor Identification: Base colorand tracer or printed numbers & color.Grounding Conductor: Where indi-cated, bare soft copper per ASTM B-3.Stranded in accordance with UL 1581.Meets or exceeds requirements of NECTable 250.122.Sheath: Close fitting, impervious, continu-ous, welded, corrugated aluminum C-L-Xper UL 1569. Exceeds grounding conduc-tor requirements of NEC Table 250-122.Jacket: Black Okoseal (PVC) per UL 1569.Meets ASTM D746-04 brittle point at -40°C.
Product Features• UL Listed as Type MC cable per E38916.*• UL 1309 (CWCMC) listed & UL classified inaccord with IEEE 1580 as Marine ShipboardCable rated 600/1000 volts.• CSA C22.2 No. 123 listed as RA90, FT4 andLTGG (-40°C).• UL Listed for cable tray use, direct burial andsunlight resistant.• Passes the IEEE 383-1974 and IEEE1202-1991 vertical tray flame tests.• Passes the 210,000 BTU ICEA T-29-520Vertical Tray Flame Test.• Complete pre-packaged, factory-tested wir-ing system — color coded.• C-L-X cables are quality control inspected tomeet or exceed applicable UL standards.• 90°C continuous operating temperature in alltypes of installations.• 130°C emergency rating.• 250°C short circuit rating.• Good EMI shielding characteristics.• Impervious, continuous metallic sheath ex-cludes moisture, gases and liquids.• Lower installed system cost than conduit orEMT systems.• Provides excellent grounding safety.• Excellent compressionand impact resistance.
• Continuous long lengths• Installation temperature of -40°C or °F.• American Bureau of Shipping Type approvedas CWCMC Type MC.• CSA Type RA90 complies with CEC Zone 2,Class II Div 2, Class III Div 1 and Class III Div2 Hazardous Locations.
* Stock items are listed MC-HL
C-L-X® Type MC (XHHW-2)600V Composite Power and Control MC Cable—Aluminum Sheath600/1000V Marine CableMultiple Copper Conductors/90°C Wet or Dry RatingFor Cable Tray Use - Sunlight Resistant - For Direct Burial
ULR
A Bare, Stranded Copper Power Con-ductors
B X-Olene Insulation—Color Codedfor Identification
C Stranded Control ConductorsD Non-Hygroscopic Fillers,
as necessaryE Binder TapeF Impervious, Continuous, Welded
Corrugated, Aluminum SheathG Black Okoseal Jacket
Product DataSection 4: Sheet 2
MC
XH
HW
-260
0V3/
C8
AW
G4/
C12
AW
G
C-L-X Type MC (XHHW-2)600V Composite Power and Control MC Cable—Aluminum Sheath— 600/1000V Marine CableMultiple Copper Conductors/90°C Wet or Dry RatingFor Cable Tray Use - Sunlight Resistant - For Direct BurialX-Olene Insulation: #14 Through #10 Awg, 30 mils (0.76mm); #8 Through #2 Awg, 45 mils (1.14mm)Okoseal Jacket: 50 mils (1.27mm)
546-31-3983546-31-3927546-31-3950546-31-3925
3X123X124X124X12
3X144X143X144X14
————
0.710.710.710.75
18.018.019.119.1
0.820.820.820.86
20.820.820.821.8
0.530.530.530.58
304320328281
374390309351
20202020
20202020
546-31-3758546-31-3992546-31-3990
� 546-31-3984
3X103X103X103X10
3X144X143X124X12
———10
0.750.800.750.75
19.120.319.119.1
0.860.910.860.86
21.823.121.821.8
0.580.650.580.58
358388296430
428453366465
30303030
20303030
546-31-3956546-31-3987546-31-3988546-31-3958
4X104X104X104X10
3X144X143X124X12
————
0.800.800.800.80
20.320.320.320.3
0.910.910.910.91
23.123.123.123.1
0.650.650.650.65
408424432455
473489497520
30303030
28282828
571-31-3192571-31-3661571-31-3664571-31-3665
3X83X83X83X8
3X144X143X124X12
————
0.800.840.800.84
20.321.320.321.3
0.910.950.910.95
23.124.123.124.1
0.650.710.650.71
420450450490
500530530570
55555555
50505050
� 571-31-3657571-31-3682571-31-3960571-31-3683
3X84X84X84X8
4X123X144X143X12
10———
0.890.840.890.89
22.621.322.622.6
0.990.951.001.00
25.124.125.425.4
0.770.710.790.79
530500525530
585580605615
55444444
50404040
571-31-3680571-31-3686571-31-3666571-31-3673
4X83X63X63X6
4X123X144X143X12
————
0.930.840.840.84
23.621.321.321.3
1.040.950.950.95
26.424.124.124.1
0.850.710.710.71
570520540550
650600620630
44757575
40656565
571-31-3668� 571-31-3667
571-31-3968571-31-3684
3X63X64X64X6
4X124X123X144X14
—8——
0.930.930.930.93
23.623.623.623.6
1.031.031.041.04
26.226.226.426.4
0.830.830.850.85
600655650660
680720730740
75756060
65655252
571-31-3685571-31-3965571-31-3655571-31-3970
4X64X63X43X4
3X124X123X144X14
————
0.970.970.930.93
24.624.623.623.6
1.081.081.041.04
27.427.426.426.4
0.920.920.850.85
680710700720
760790780800
60609595
52528585
571-31-3671571-31-3974
� 571-31-3677571-31-3688
3X43X43X44X4
3X124X124X123X14
——8—
0.930.970.971.06
23.624.624.726.9
1.041.081.081.17
26.427.427.529.7
0.850.920.921.08
720760810890
800840895970
95959576
85858568
571-31-3669571-31-3670571-31-3672571-31-3203
4X44X44X43X2
4X143X124X123X14
————
1.061.061.061.06
26.926.926.926.9
1.171.171.171.17
29.729.729.729.7
1.081.081.081.08
920920950985
1000100010301065
767676
130
686868
115571-31-3674571-31-3675571-31-3505571-31-3506
3X23X23X24X2
4X143X124X123X14
————
1.061.061.061.15
26.926.926.929.2
1.171.171.171.26
29.729.729.732.0
1.081.081.081.25
1000101010401230
1080109011151320
130130130104
11511511592
571-31-3507571-31-3508571-31-3509
4X24X24X2
4X143X124X12
———
1.151.151.15
29.229.229.2
1.261.261.26
32.032.032.0
1.251.251.25
125012601280
134013501370
104104104
929292
ULR
Control C
onductors
Number
XSize
Cross
-Sec
tional
Area (s
q. in.)�
Approx.
ShipW
eight
lbs./
1000
’
Catalo
gNum
ber
Cable
O.D. -
Inch
es
C-L-X
O.D. -
mm
Groundin
gConduct
or
AWG
Cable
O.D. -
mm
75°C
Wet
NECAm
pacity
Approx.
NetW
eight
lbs./
1000
’
PowerConduct
ors
Number
XSize
90°C
Wet
or Dry
NECAm
pacity
(1)
Product DataSection 4: Sheet 2
Visit Okonite's web site, www.okonite.com for the most up to datedimensions.
� Authorized Stock Item - Available from our Service Centers.These stock items are listed as MC-HL.
Copper or Bronze C-L-X is available on special order.
JacketsOptional jacket types available - consult local sales office.
�Cross-sectional area for calculation of cable tray fill in accordance withNEC Section 392.22.
(1) AmpacitiesAmpacities are based on Table 310.15(B)(16) of the National Electrical Codefor XHHW-2 conductors rated 90°C, in a multi-conductor cable, at an ambienttemperature of 30°C (86F). The 75°C column is provided for additional informa-tion.
The ampacities shown apply to open runs of cable, installation in any ap-proved raceway, direct burial in the earth, or as aerial cable on a messenger.Derating for more than three current carrying conductors within the cable is inaccordance with NEC Section 310.15(B)(3)(a).
The ampacities shown also apply to cable installed in cable tray in accor-dance with NEC Section 392.80
G/15100402
C-L-X
O.D. -
Inch
es
THE OKONITE COMPANYRamsey, New Jersey 07446
A
B
E
D
C
InsulationOkonite-FMR is Okonite’s trade name for itsheat, moisture, flame and chemical resistant,mechanically rugged ethylene-propylene in-sulating compound.The properties of Okonite-FMR insulationsubstantially enhance the well known fea-tures of ethylene-propylene rubber insula-tions.
Overall JacketThe Okoseal (PVC) jacket is mechanicallyrugged and has excellent resistance to mostchemicals.
ApplicationsOkonite-FMR Okoseal Type TC-ER tray ca-ble is permitted for use on power, lighting,control, and signal circuits; indoors or out-doors; in cable trays, raceways, direct burialin the ground, or where supported in outdoorlocations by a messenger wire; for Class 1circuits as permitted in Article 725 of theNEC; and in cable trays in Class I, Division 2hazardous locations in industrial establish-ments where the conditions of maintenanceand supervision assure that only qualifiedpersons will service the installation. Cablesmarked TC-ER may also be used between acable tray and the utilization equipment ordevice, when installed in accordance withNEC 336.10(7).As Type Oko-Marine cable, it is suitable foruse in marine shipboard and off-shore plat-form applications in accordance with API andABS requirements.
SpecificationsConductors: Uncoated soft copper perASTM B-3. Sizes smaller than #8 are com-press stranded per ASTM B-8. Sizes #8 andlarger are compact stranded per ASTMB-496.Insulation: Okonite-FMR meets or exceedsrequirements of UL 1581, ICEA S-73-532(NEMA WC57) and ICEA S-95-658 NEMAWC70 Type II insulation.Color Coding: Base colors and tracers asshown on reverse of Data Sheet and forsizes #8 AWG and larger black conductorswith surface printing of numbers per ICEAS-73-532 NEMA/WC57 Method 4.Grounding Conductor: Where indicated,bare stranded copper per ASTM B-8, orcompact round per ASTM B-496, Class B &NEC Table 250.122.
Assembly: Conductors cabled in accor-dance with UL 1277 and 1309 using fill-ers, as necessary, with a cable tapeoverall.Overall Jacket: Complies with UL 1277and 1309. The Okoseal compound meetsor exceeds the requirements of UL 1581.UL Listed as Type TC or TC-ER cablewith a sunlight resistant low temperaturejacket and for direct burial and TypeOko-Marine cable.Sizes 4 AWG and larger without agrounding conductor are Type TC only(not ER).
Product FeaturesInsulated conductors are UL rated VW-1.90°C continuous rating in wet or dry130°C emergency overload rating250°C short circuit rating.Okonite-FMR Okoseal Type TC-ER andOko-Marine cables are quality control in-spected to meet or exceed applicable in-dustry standards.Resistant to moisture and most chemicalatmospheres.Thermal stability at elevated tempera-tures.Flexible, easy to install and terminate.High dielectric strength.Installation Temperature -35°C.
Applicable Standards• UL listed for cable tray use, directburial, in ducts, and sunlight resistant.• Vertical Tray Flame Tests;IEEE 383-1974, FT4/IEEE 1202, UL1277, Sizes 250 kcmil and larger meetICEA T-29-520 (210,000 BTU/hr).• OSHA Acceptable• UL 1309-Oko-Marine• UL certified to IEEE 1580 - MarineShipboard Cable rated 600/1000V.• ABS Type approved; API-RP-14F,IEEE 45 & 1202, 46 CFR 111.60.• CSA C22.2 No. 239 Type CIC for sizes4/0 AWG and smaller.• CSA C22.2 No. 245 Type Marine Ship-board.
Okonite-FMR® Okoseal® TypeUL Type TC/TC-ER and cUL CIC 600V Power & Control Tray Cable
or Oko-Marine Cable 600/1000VMultiple Copper Conductors With or WithoutGrounding Conductor/90°C Wet or DryFor Cable Tray Use - Sunlight Resistant - For Direct Burial
Product DataSection 4: Sheet 5
A Stranded Copper ConductorsB Okonite-FMR InsulationC Fillers, as necessaryD Binder TapeE Okoseal Jacket — Black
ULR
AW
GC
UO
KO
NIT
E-F
MR
PV
C60
0V
c ULR
UL TYPE: TC-ER
� 202-10-3203� 202-10-3204
14(7X)
34
30
——
4545
1.141.14
0.400.44
10.211.2
0.130.16
104126
127149
1515
1515
� 202-10-3205� 202-10-3207
202-10-3209
579
———
454560
1.141.141.52
0.480.520.63
12.213.216.0
0.180.220.32
151195260
174218292
151515
151414
� 202-10-3212� 202-10-3219� 202-10-3237
121937
———
606080
1.521.522.03
0.710.821.14
18.020.829.0
0.400.541.03
332480925
364519
1005
121210
10108
� 202-10-3403� 202-10-3443
12(7X)
33
30
—12*
4545
1.141.14
0.440.48
11.212.2
0.160.18
134162
157185
2020
2020
� 202-10-3404� 202-10-3405� 202-10-3407
457
———
454560
1.141.141.52
0.480.520.60
12.213.215.2
0.190.220.29
167202281
190225305
202020
202017
� 202-10-3409� 202-10-3412� 202-10-3419
202-10-3437
9121937
————
60608080
1.521.522.032.03
0.700.780.951.26
17.819.824.132.0
0.390.490.731.27
363446697
1266
395485752
1266
20151512
17121210
� 202-10-3503� 202-10-3543� 202-10-3504
202-10-3505 10(7X)
3345 30
—10*——
45456060
1.141.141.521.52
0.490.530.570.62
12.413.514.515.7
0.200.230.260.31
183223243294
206247267318
30303030
30302828
202-10-3507202-10-3509202-10-3512
7912
———
606080
1.521.522.03
0.670.780.92
17.019.823.4
0.370.490.68
384494669
416533724
282820
242417
Visit Okonite's web site, www.okonite.com, for the most up to date dimensions.
ULR
Okonite-FMR Okoseal®UL Type TC/TC-ER and cUL CIC 600V Power & Control TrayCable or Oko-Marine Cable 600/1000VMultiple Copper Conductors With or WithoutGrounding Conductor/90°C Wet or Dry RatingFor Cable Tray Use - Sunlight Resistant - for Direct Burial
Product DataSection 4: Sheet 5
� Authorized stock item —Available from our Service Centers.
Equipment Grounding Conductor: Any conductor in these cables may be per-manently re-identified during installation as the equipment grounding conductorin accordance with Section 250.119.B of the NEC.
† Cross-sectional area for calculation of cable tray fill in accordance with Sec-tion 392.22 of the NEC.
(1) Ampacities
Ampacities are based on Table 310-15(B)(16) of the National Electrical Codefor conductors rated 90°C, in a multi-conductor cable, at an ambient tempera-ture of 30°C (86°F). The 75°C column is provided for additional information.
The ampacities shown apply to open runs of cable, installation in any approvedraceway, direct burial in the earth, or as aerial cable on a messenger. Deratingfor more than three current carrying conductors within the cable is in accor-dance with NEC Section 310.15(B)(3)(a)
The ampacities shown also apply to cables installed in cable tray in accordancewith NEC Section 392.80.
Conductor Size
AWG/kc
mil
Number
of Conductors
Groundin
gConduct
or AWG
Catalo
gNum
ber
Jack
etThick
ness (m
ils)
90°C
Wet
or Dry
NECAm
pacity
(1)
Jack
etThick
ness (m
m)
Cross
-Sec
tional
Area (s
q. In.)
�
75°C
Wet
NECAm
pacity
(1)
Approx.
O.D. (
In.)
Approx.
NetW
eight
lbs./
1000
’
Approx.
ShipW
eight
lbs./
1000
’
Approx.
O.D. (
mm
)
Insu
latio
nThick
ness (m
ils)
c ULR
112-10-3842� 112-10-3844
112-10-3845112-10-3847
8(7X) TC-ER
3344
45
—10*—10*
60606060
1.521.521.521.52
0.640.700.700.73
16.317.817.818.5
0.320.380.380.42
273349352412
305388391451
55554545
50504040
112-10-3852� 112-10-3854
112-10-3855112-10-3857
6(7X) TC-ER
3344
45
—8*—8*
60606060
1.521.521.521.52
0.720.760.790.83
18.319.320.121.1
0.410.450.490.54
382437493582
421469532637
75756060
65655252
112-10-3862� 112-10-3864
112-10-3865112-10-3867
4(7X)
TCTC-ER
TCTC-ER
3344
45
—8*—8*
60808080
1.522.032.032.03
0.810.840.941.00
20.621.323.925.4
0.520.550.690.79
549696750891
588751805955
95957676
85856868
112-10-3872� 112-10-3874
112-10-3875112-10-3877
2(7X)
TCTC-ER
TCTC-ER
3344
45
—6—6
80808080
2.032.032.032.03
0.990.991.091.12
25.125.127.728.4
0.770.770.930.99
888941
11331242
952100512001322
130130104104
115115
9292
112-10-3882112-10-3884112-10-3885112-10-3887
1(19X)
TCTC-ER
TCTC-ER
3344
55
—6—6
80808080
2.032.032.032.03
1.101.101.211.21
27.927.930.730.7
0.950.951.151.15
1103118014341505
1170124715341605
150150120120
130130104104
112-10-3892� 112-10-3894
112-10-3895112-10-3897
1/0(19X)
TCTC-ER
TCTC-ER
3344
55
—6—6
80808080
2.032.032.032.03
1.181.181.301.23
30.030.033.031.2
1.091.091.331.19
1330141017411812
1410149018411912
170170136136
150150120120
112-10-3902� 112-10-3904
112-10-3905112-10-3907
2/0(19X)
TCTC-ER
TCTC-ER
3344
55
—6—6
80808080
2.032.032.032.03
1.271.271.401.40
32.332.335.635.6
1.271.271.541.54
1632171121142186
1732181122302302
195195156156
175175140140
112-10-3922� 112-10-3924
112-10-3925112-10-3927
4/0(19X)
TCTC-ER
TCTC-ER
3344
55
—4—4
80808080
2.032.032.032.03
1.481.481.641.64
39.439.450.050.0
————
2462257632063320
2605271933833497
260260208208
230230184184
112-10-3928112-10-3929112-10-3930112-10-3931
250(37X)
TCTC-ER
TCTC-ER
3344
65
—4—4
8080
110110
2.032.032.792.79
1.621.621.861.86
44.744.749.349.3
————
2904302938934000
3047320641594265
290290232232
255255185185
112-10-3932� 112-10-3933
112-10-3934112-10-3935
350(37X)
TCTC-ER
TCTC-ER
3344
65
—3—3
110110110110
2.792.792.792.79
1.891.892.082.08
50.350.355.655.6
————
3995416452435394
4261443055905741
350350280280
310310248248
112-10-3936� 112-10-3937
112-10-3938112-10-3939
500(37X)
TCTC-ER
TCTC-ER
3344
65
—2—2
110110110110
2.792.792.792.79
2.142.142.372.37
57.457.463.563.5
————
5549574372377425
5939613377967984
430430344344
380380304304
112-10-3940112-10-3941112-10-3942112-10-3943
750(61X)
TCTC-ER
TCTC-ER
3344
80
—1—1
110110140140
2.792.793.563.56
2.582.582.922.92
68.668.676.576.5
————
82778515
1094211157
89049142
1170411919
535535428428
475475380380
112-10-3944112-10-3945112-10-3946112-10-3947
1000(61X)
TCTC-ER
TCTC-ER
3344
80
—1/0—1/0
140140140140
3.563.563.563.56
2.962.963.283.28
77.277.285.685.6
————
10953112371433714632
11715120001527015565
615615492492
545545436436
Note: Sizes 4 AWG & larger without a grounding conductor are type TC only (not ER rated).*Ground size marked with asterisk are green insulated. **Grounds may be split.Visit Okonite's web site, www.okonite.com, for the most up to date dimensions.
Product DataSection 4: Sheet 5
Approx.
NetW
eight
lbs./
1000
’
75°C
Wet
NEC
Ampac
ity(1
)
90°C
Wet
or Dry
NECAm
pacity
(1)
Approx.
ShipW
eight
lbs./
1000
’
Conductor Size
AWG/kc
mil
Number
of Conductors
Groundin
gConduct
or AWG**
ULTC
TYPE
Jack
etThick
ness (m
ils)
Jack
etThick
ness (m
m)
Insu
latio
nThick
ness (m
ils)
Cross
-Sec
tional
Area (s
q. In.)
�
Approx.
O.D. (
In.)
Approx.
O.D. (
mm
)
Catalo
gNum
ber
Okonite-FMR OkosealUL Type TC/TC-ER and cUL CIC 600V Power & Control TrayCable or Oko-Marine Cable 600/1000VMultiple Copper Conductors With or WithoutGrounding Conductor/ 90°C Wet or DryFor Cable Tray Use - Sunlight Resistant - For Direct Burial
Conductor Color Coding SequenceSizes 14, 12 & 10 AWG
Conductor Color Coding per ICEA Method 1,Number Base Color Tracer Color E-2
1 Black Sizes 8 AWG and larger:2 Red Surface Printing of Numbers per3 Blue ICEA Method 44 Orange5 Yellow6 Brown7 Red Black8 Blue Black9 Orange Black
10 Yellow Black11 Brown Black12 Black Red13 Blue Red14 Orange Red15 Yellow Red16 Brown Red17 Black Blue18 Red Blue19 Orange Blue20 Yellow Blue21 Brown Blue22 Black Orange23 Red Orange24 Blue Orange25 Yellow Orange26 Brown Orange27 Black Yellow28 Red Yellow29 Blue Yellow30 Orange Yellow31 Brown Yellow32 Black Brown33 Red Brown34 Blue Brown35 Orange Brown36 Yellow Brown37 Black
Special Order: Any or all of the following conductors may be added when specifi-cally requested by the customer to meet his specific application requirements.These conductor codings comply with UL and NEC requirements.
Purpose Base Color Tracer Color
Equipment Grounding UninsulatedGreenGreen 1 or more continuous yellow stripes
Grounded WhiteWhiteWhiteWhiteWhiteWhiteWhite
Black continuous stripeRed continuous stripeBlue continuous stripeOrange continuous stripeBrown continuous stripeNumeric Printing
H\15080405
Product DataSection 4: Sheet 5
ULR
THE OKONITE COMPANYRamsey, New Jersey 07446
c ULR
InsulationX-Olene® is Okonite’s trade name for itscross-linked polyethylene, with high dielectricstrength insulation.
JacketThe Okoseal (PVC) jacket supplied with thiscable is mechanically rugged and has excel-lent resistance to acids and most chemicalsand is rated for low temperature installations.
ApplicationsOkonite X-Olene Okoseal tray cable is per-mitted for use on power, lighting, control, andsignal circuits; indoors or outdoors; in cabletrays, raceways, direct burial in the ground,or where supported in outdoor locations by amessenger wire; for Class 1 circuits as per-mitted in Article 725 of the NEC; and in cabletrays in Class I, Division 2 hazardous loca-tions in industrial establishments where theconditions of maintenance and supervisionassure that only qualified persons will servicethe installation. Cables marked TC-ER mayalso be used between a cable tray and theutilization equipment or device, when in-stalled in accordance with NEC 336.10(7).
SpecificationsConductors: Uncoated soft copper perASTM B-3. Sizes smaller than #8 are com-press stranded per ASTM B-8. Sizes #8 andlarger are compact stranded per ASTMB-496.Insulation: X-Olene insulation per UL 1581,listed as XHHW-2.Color Coding: Base colors and tracers asshown on reverse of Data Sheet and, forsizes #8 AWG and larger, black conductorswith surface printing of numbers and colorsper ICEA S-73-532 NEMA/WC57 Method 3.Assembly: Conductors cabled in accor-dance with UL 1277 using fillers and tape, asneeded.Grounding Conductor: Where indicated,bare or insulated stranded copper in accor-dance with NEC Table 250.122.Overall Jacket: Complies with UL 1277. TheOkoseal compound meets or exceeds the re-quirements of UL 1581.
Cable passes the Vertical Tray FlameTest requirements of UL 1277 for TypeTC Power and Control Tray Cable.UL Listed as Type TC or TC-ER cablewith a sunlight resistant jacket and for di-rect burial.
Product FeaturesInsulated conductors are UL Listed TypeXHH / XHHW-2.90°C continuous rating in wet or dry loca-tions.130°C emergency overload rating.250°C short circuit rating.X-Olene Okoseal Type TC or TC-ER ca-bles are quality control inspected to meetor exceed applicable industry standards.Resistant to moisture and most chemicalatmospheres.Thermal stability at elevated tempera-tures.Easy to install and terminate.Mechanically rugged.High dielectric strength.Small diameter, lightweight.Minimum installation temperature of-40°C.
Applicable Standards• UL listed for cable tray use, directburial, in ducts, and sunlight resistant.
• Vertical Tray Flame Tests: IEEE383-1974, Sizes 4/0 AWG and largermeet FT4/IEEE 1202.
• CSA C22.2 No. 239 Type CIC for sizes4/0 AWG and smaller.
Product DataSection 4: Sheet 8
X-Olene®-Okoseal®UL Type TC/TC-ER (XHH/XHHW-2) and cUL CIC600 Volt Power and Control Tray CableMultiple Copper Conductors, 90°C Wet or DryWith or Without Grounding ConductorFor Cable Tray Use - Sunlight Resistant - For Direct Burial
A Uncoated Copper ConductorsB X-Olene InsulationC Fillers, as requiredD Black Okoseal Jacket
A
B
D
C
7/C
14A
WG
CU
X-O
LE
NE
XL
P60
0V(U
L)
TC
-ER
XH
HW
-2
ULR c ULR
UL TYPE: TC-ER
202-31-3813� 202-31-3823� 202-31-3833
14(7X)12(7X)10(7X)
333
303030
1#141#121#10
454545
1.141.141.14
.43
.47
.53
10.911.913.5
0.150.170.22
120171238
135187254
152030
152030
� Authorized Stock Item - Available from our Service Centers.
Equipment Grounding Conductor: Any conductor in these cablesmay be permanently re-identified during installation as the equipmentgrounding conductor in accordance with Section 250.119.B of theNEC.
� Cross-sectional area for calculation of cable tray fill in accordancewith NEC Section 392.22.
��� Ampacities
Ampacities are based on Table 310.15(B)(16) of the National Electri-cal Code for XHHW-2 conductors rated 90°C, in a multi-conductorcable, at an ambient temperature of 30°C (86°F). Derating for morethan three current carrying conductors within the cable is in accor-dance with NEC Section 310.15(B)(3)(a).
The ampacities shown also apply to cables installed in cable tray inaccordance with NEC Section 392.80.
Product DataSection 4: Sheet 8
X-Olene-OkosealUL Type TC/TC-ER (XHH/XHHW-2) and cUL CIC600V Power and Control Tray CableMultiple Copper Conductors, 90°C Wet or DryWith or Without Grounding ConductorFor Cable Tray Use - Sunlight Resistant - For Direct Burial
� 202-31-3502� 202-31-3503� 202-31-3504
14(7X)(2.08mm2)
TCTC-ERTC-ER
234
30(0.76mm)
454545
1.141.141.14
0.370.410.43
9.410.410.9
0.110.130.15
70105120
85120135
151515
151515
� 202-31-3505� 202-31-3507� 202-31-3509
TC-ERTC-ERTC-ER
579
454560
1.141.141.52
0.470.500.62
11.912.715.7
0.170.200.30
132182254
148205278
151515
151414
� 202-31-3512202-31-3519202-31-3537
TC-ERTC-ERTC-ER
121937
606080
1.521.522.03
0.690.801.11
17.620.328.2
0.380.500.97
306446856
338485936
121210
10108
� 202-31-3602� 202-31-3603� 202-31-3604
12(7X)(3.31mm2)
TCTC-ERTC-ER
234
30(0.76mm)
454545
1.141.141.14
0.400.440.47
10.211.211.9
0.130.150.17
92139171
107152187
202020
202020
� 202-31-3605� 202-31-3607� 202-31-3609
TC-ERTC-ERTC-ER
579
456060
1.141.521.52
0.520.590.68
13.115.017.3
0.210.270.36
179269344
195293376
202020
201717
� 202-31-3612202-31-3619202-31-3637
TC-ERTC-ERTC-ER
121937
608080
1.522.032.03
0.770.951.24
19.624.131.5
0.470.711.21
425640
1200
464704
1290
151512
121210
� 202-31-3702� 202-31-3703� 202-31-3704
202-31-3705 10(7X)(5.26mm2)
TCTC-ERTC-ERTC-ER
2345 30
(0.76mm)
45454560
1.141.141.141.52
0.450.480.530.61
11.412.213.515.5
0.160.180.220.29
122183238294
138199254318
30303030
30302828
202-31-3707202-31-3709202-31-3712
TC-ERTC-ERTC-ER
79
12
606080
1.521.522.03
0.660.770.91
16.819.623.1
0.340.470.65
378485643
410524698
282820
242417
Catalo
gNum
ber
Conductor Size
AWG/kc
mil
Approx.
O.D. -
Inch
es
90°C
Wet
or Dry
NECAm
pacity
(1)
Approx.
NetW
eight
lbs./
1000
’
75°C
Wet
NECAm
pacity
(1)
Approx.
ShipW
eight
lbs./
1000
’
Approx Cro
ss-S
ectio
nal
Area (s
q. in.)�
Number
of Conductors
Approx.
O.D. -
mm
Jack
etThick
ness - m
m
Jack
etThick
ness - m
ils
Green
Insu
lated
Groundin
gConduct
or AWG
Catalo
gNum
ber
Conductor Size
AWG/kc
mil
Approx.
O.D. -
Inch
es
90°C
Wet
or Dry
NECAm
pacity
(1)
Approx.
NetW
eight
lbs./
1000
’
75°C
Wet
NECAm
pacity
(1)
Approx.
ShipW
eight
lbs./
1000
’
Approx.
Cross
-Sec
tional
Area (s
q. in.)�
ULTYPE
Approx.
O.D. -
mm
Jack
etThick
ness - m
m
Jack
etThick
ness - m
ils
Insu
latio
nThick
ness - m
ils
Insu
latio
nThick
ness - m
ils
ULR c ULR
Number
of Conductors
Visit Okonite's web site, www.okonite.com, for the most up to date dimensions. Product DataSection 4: Sheet 8
Catalo
gNum
ber
Conductor Size
AWG/kc
mil
Approx.
O.D. -
Inch
es
Approx.
NetW
eight
lbs./
1000
’
Approx.
ShipW
eight
lbs./
1000
’
Approx.
Cross
-Sec
tional
Area (s
q. in.)�
ULTYPE
Approx.
O.D. -
mm
Jack
etThick
ness - m
m
Jack
etThick
ness - m
ils
Insu
latio
nThick
ness - m
ils
112-31-3734� 112-31-3735
112-31-3736112-31-3737
8(7X)(8.36mm2)
TC-ERTC-ERTC-ERTC-ER
3344
45
—10—10
60606060
1.521.521.521.52
0.640.660.700.72
16.316.717.818.3
0.320.340.390.41
259313331385
298352370424
55554444
50504040
112-31-3746� 112-31-3747
112-31-3748112-31-3749
6(7X)(13.3mm2)
TC-ERTC-ERTC-ERTC-ER
3344
45
—8—8
60606060
1.521.521.521.52
0.710.740.780.82
18.018.819.820.8
0.400.430.480.53
365440471552
404479510616
75756060
65655252
112-31-3758� 112-31-3759
112-31-3760112-31-3761
4(7X)(21.2mm2)
TCTC-ER
TCTC-ER
3344
45
—8—8
60608080
1.521.522.032.03
0.810.810.930.96
20.620.623.624.4
0.520.520.680.72
527662720808
566715784872
95957676
85856868
112-31-3764� 112-31-3765
112-31-3766112-31-3767
2(7X)(33.6mm2)
TCTC-ER
TCTC-ER
3344
45
—6—6
80808080
2.032.032.032.03
0.970.971.071.11
24.624.627.228.2
0.740.740.900.97
816101810601196
880109811401276
130130104104
115115
9292
112-31-3770112-31-3771112-31-3772112-31-3773
1(19X)(42.4mm2)
TCTC-ER
TCTC-ER
3344
55
—6—6
80808080
2.032.032.032.03
1.091.091.201.20
27.727.730.530.5
0.930.931.131.13
1051112713551431
1118119414351511
150150120120
130130104104
112-31-3776� 112-31-3777
112-31-3778112-31-3779
1/0(19X)(53.5mm2)
TCTC-ER
TCTC-ER
3344
55
—6—6
80808080
2.032.032.032.03
1.171.171.291.29
29.720.732.832.8
1.081.081.311.31
1274135016521729
1354143017521829
170170136136
150150120120
112-31-3780� 112-31-3781
112-31-3782112-31-3783
2/0(19X)(67.4mm2)
TCTC-ER
TCTC-ER
3344
55
—6—6
80808080
2.032.032.032.03
1.261.261.391.39
32.032.035.335.3
1.251.251.521.52
1561163920332109
1661173921492225
195195156156
175175140140
112-31-3784� 112-31-3785
112-31-3786112-31-3787
4/0 (19X)(107mm2)
TCTC-ER
TCTC-ER
3344
55
—4—4
80808080
2.032.032.032.03
1.471.471.631.63
37.337.341.441.4
————
2361248831013222
2504263132783399
260260208208
230230184184
112-31-3788112-31-3789112-31-3790112-31-3791
250(37X)(127mm2)
TCTC-ER
TCTC-ER
3344
65
—4—4
8080
110110
2.032.032.792.79
1.621.621.851.85
41.241.247.047.0
————
2796291737783899
2939306040444165
290290232232
255255185185
112-31-3792� 112-31-3793
112-31-3794112-31-3795
350(37X)(177mm2)
TCTC-ER
TCTC-ER
3344
65
—3—3
110110110110
2.792.792.792.79
1.881.882.082.08
47.847.852.852.8
————
3889404450915245
4155431054385592
350350280280
310310248248
112-31-3796� 112-31-3797
112-31-3798112-31-3799
500(37X)(253mm2)
TCTC-ER
TCTC-ER
3344
65
—2—2
110110110110
2.792.792.792.79
2.132.132.362.36
54.154.159.959.9
————
5386558170827276
5733592876417835
430430344344
380380304304
112-31-3800� 112-31-3801
112-31-3802112-31-3803
750(61X)(380mm2)
TCTC-ER
TCTC-ER
3344
80
—1—1
110110140140
2.792.793.563.56
2.562.562.902.90
65.065.073.773.7
————
79618206
1063210879
85208833
1139411641
535535428428
475475380380
112-31-3804112-31-3805112-31-3806112-31-3807
1000(61X)(507mm2)
TCTC-ER
TCTC-ER
3344
80
—1/0—1/0
140140140140
3.563.563.563.56
2.932.933.253.25
74.474.482.682.6
————
10584108941392514235
11346116561485815168
615615492492
545545436436
NOTE: Sizes 4AWG & larger without a grounding conductor are Type TC only (Not ER rated).
90°C
Wet
or Dry
NECAm
pacity
(1)
75°C
Wet
(1)
NECAm
pacity
Groundin
gConduct
or
AWG
Number
of Conductors
X-Olene-OkosealUL Type TC/TC-ER (XHH/XHHW-2) and cUL CIC600 Volt Power and Control Tray CableMultiple Copper Conductors, 90°C Wet or DryWith or Without Grounding ConductorFor Cable Tray Use - Sunlight Resistant - For Direct Burial
Conductor Color Coding SequenceConductor
Number Base Color Tracer Color Color CodingSizes 14, 12 & 10 AWG:per ICEA Method 1, E-2 color se-quence
Sizes 8 AWG and larger:Surface Printing of Numbers andcolor designation per ICEAMethod 3, E-2 color sequence
1 Black2 Red3 Blue4 Orange5 Yellow6 Brown7 Red Black
8 Blue Black
9 Orange Black10 Yellow Black11 Brown Black12 Black Red13 Blue Red14 Orange Red15 Yellow Red16 Brown Red17 Black Blue18 Red Blue19 Orange Blue20 Yellow Blue21 Brown Blue22 Black Orange23 Red Orange24 Blue Orange25 Yellow Orange26 Brown Orange27 Black Yellow28 Red Yellow29 Blue Yellow30 Orange Yellow31 Brown Yellow32 Black Brown33 Red Brown34 Blue Brown35 Orange Brown36 Yellow Brown37 Black
Special Order: Any or all of the following conductors may be added whenspecifically requested by the customer to meet his specific applicationrequirements. These conductor codings comply with UL and NECrequirements.
Purpose Base Color Tracer Color
Equipment Grounding UninsulatedGreenGreen 1 or more continuous yellow stripes
Grounded WhiteWhiteWhiteWhiteWhiteWhiteWhite
Black continuous stripeRed continuous stripeBlue continuous stripeOrange continuous stripeBrown continuous stripeNumeric Printing
G/15050408
Product DataSection 4: Sheet 8
THE OKONITE COMPANYRamsey, New Jersey 07446
ULR c ULR
InsulationX-Olene® is Okonite's trade name for its chemi-cally cross-linked polyethylene, with highdielectric strength.
Color CodingConductors are color coded using base colorsand tracers in accordance with the ConductorIdentification Table on the back of this DataSheet.
Assembly and CoveringsThe individual conductors are cabled togetherwith non-hygroscopic fillers and a binder tapeoverall. The C-L-X sheath exceeds the ground-ing conductor requirements of Table 250.122 ofthe NEC and UL 1569.The impervious, continuous, corrugated alumi-num C-L-X sheath provides complete protectionagainst moisture, liquids and gases and has ex-cellent mechanical strength. For direct burial inthe ground, embedment in concrete, or for ar-eas subjected to corrosive atmospheres, theC-L-X sheath is protected with a low tempera-ture black Okoseal® (PVC) jacket.
ApplicationsC-L-X Type MC cables with the impervious,continuous, corrugated aluminum sheath arerecommended as an economical alternate to awire in conduit system.They are authorized for use on services, feed-ers and branch circuits for power, lighting,control and signaling circuits in accordance withArticles 330 and 725 of the NEC.C-L-X Type MC cables may be installed indoorsor outdoors, in wet or dry locations, as openruns of cable secured to supports spaced notmore than six feet apart, in cable tray, as aerialcable on a messenger, in any approved race-way, direct burial, or encased in concrete.C-L-X Type MC cables are also approved foruse in Class I & II, Division 2, Class III, Divi-sions 1 and 2, and Class I, Zone 2 hazardouslocations per NEC articles 501, 502, 503 and505; in Zone 2, Class II Div 2, Class III Div 1and Class III Div 2 per CEC.
SpecificationsConductors: Bare soft annealed copper, ClassB stranding per ASTM B-8.Insulation: X-Olene per ICEA S-73-532/ NEMAWC57 and UL 44, Listed UL Type XHHW-2.Meets MIL-DTL-1377H, section 4.8.4.1.2 coldbend at -66°C and ASTM D746-04 brittle pointat -76°C.Conductor Identification: Base Colors andtracers.Assembly: Per UL 1569 with binder tape over-all.
Sheath: Close fitting, impervious, continu-ous, corrugated aluminum C-L-X per UL1569.Exceeds grounding conductor requirementsof NEC Table 250.122.Jacket: Black Okoseal (PVC) per UL re-quirements for Type MC Cables. MeetsASTM D746-04 brittle point at -40°C.
Product Features• UL Listed as Type MC cable and MarineShipboard Cable, E38916 (UL 1596) andE137931 (UL 1309).• UL Listed for cable tray use, direct burialand sunlight resistant.• UL 1309 (CWCMC) listed & UL classifiedin accord with IEEE 1580 as Marine Ship-board Cable rated 600/1000 volts.• CSA C22.2 No. 123 listed as RA90, FT4and LTGG (-40°C).• Passes the IEEE 383-1974 and IEEE1202 vertical tray flame tests.• Passes the 210,000 BTU/hr ICEAT-29-520 Vertical Tray Flame Test.• Complete pre-packaged, factory-testedwiring system — color coded.• C-L-X cables are quality control inspectedto meet or exceed applicable UL standards.• 90°C continuous operating temperature inall types of installations• 130°C emergency rating• 250°C short circuit rating.• Good EMI shielding characteristics.• Impervious, continuous metallic sheathexcludes moisture, gases and liquids.• Lower installed system cost than conduitor EMT systems.• Provides excellent grounding safety• Excellent compression and impact resis-tance.• Continuous long lengths.• Installation temperature of -40°C or °F.• UL and American Bureau of ShippingType approved as CWCMC Type MC.• CSA Type RA90 complies with CEC Zone2, Class II Div 2, Class III Div 1, Class IIIDiv 2 Hazardous Locations.
C-L-X® Type MC (XHHW-2)600V Control Cable — Aluminum Sheath600/1000V Marine CableMultiple Copper Conductors/90°C Wet or Dry RatingFor Cable Tray Use - Sunlight Resistant - For Direct Burial
Product DataSection 4: Sheet 14
ULR
A
B
E
F
D
G
C
A Bare, StrandedCopper Conductors
B X-Olene Insulation - ColorCoded for Identification
C Marker TapeD Non-hygroscopic Fillers,
as necessaryE Binder TapeF Impervious, Continuous, Cor-
rugated, Aluminum C-L-XSheath
G Black Okoseal Jacket
600V
7/C
12
AW
GC
U
� Authorized Stock Item - Available from our Service Centers.
Copper or Bronze C-L-X - is available on special order.
� Cross-sectional area for calculation of cable tray fill in accordance with NECSection 392.22.
Jackets - Optional jacket types available - consult local sales office.
(1)Ampacities
Ampacities are based on Table 310.15(B)(16) of the National Electrical Code forXHHW-2 conductors rated 90°C, in a multi-conductor cable, at an ambient tem-perature of 30°C (86F). The 75°C column is provided for additional information.
The ampacities shown apply to open runs of cable, installation in any approvedraceway, direct burial in the earth, or as aerial cable on a messenger. Derating formore than three current carrying conductors within the cable is in accordance withNEC Section 310.15(B)(3)(a).
The ampacities shown also apply to cables installed in cable tray in accordancewith NEC Section 392.80.
Product DataSection 4: Sheet 14
C-L-X Type MC (XHHW-2)600V Control Cable—Aluminum Sheath600/1000V Marine CableMultiple Copper Conductors/90°C Wet or Dry RatingFor Cable Tray Use - Sunlight Resistant - For Direct Burial
546-31-3002� 546-31-3003� 546-31-3004
14(7X)(2.08mm2)
234
30(0.76mm)
0.280.300.33
7.17.68.4
0.490.490.53
12.312.413.5
50 1.27
0.600.600.64
15.115.216.3
0.280.320.36
142153181
174185214
151515
151515
� 546-31-3005� 546-31-3007� 546-31-3009
579
0.370.410.50
9.410.412.7
0.580.620.71
14.715.718.0
0.690.730.82
17.518.520.8
0.410.460.57
210254308
242309363
151515
151414
*� 546-31-3012*� 546-31-3019*� 546-31-3037
121937
0.570.690.96
14.417.524.4
0.800.931.24
20.323.631.5
0.911.041.35
23.126.434.3
0.710.841.43
381537946
448604
1036
121210
10108
546-31-3082� 546-31-3083� 546-31-3084
12(7X)(3.31mm2)
234
30(0.76mm)
0.310.340.38
7.88.69.6
0.530.530.58
13.513.514.7
50 1.27
0.640.640.69
16.316.317.5
0.320.320.38
164189226
196221258
202020
202020
� 546-31-3085� 546-31-3087� 546-31-3089
579
0.420.470.56
10.611.914.2
0.620.670.80
15.717.020.3
0.730.780.91
18.519.823.1
0.420.480.65
262324405
317379472
202020
201717
*� 546-31-3092*� 546-31-3099*� 546-31-3117
121937
0.650.781.08
16.519.827.4
0.891.021.37
22.625.934.8
0.991.131.48
25.428.737.6
0.791.001.72
503721
1301
570801
1444
151512
121210
546-31-3162� 546-31-3163� 546-31-3164
10(7X)(5.26mm2)
234
30(0.76mm)
0.360.390.44
9.19.9
11.1
0.580.580.67
14.714.717.0
50 1.27
0.690.690.78
17.517.519.8
0.380.380.48
202238297
234270352
303030
303028
546-31-3165� 546-31-3167
546-31-3169546-31-3172*
579
12
0.480.540.650.74
12.213.716.518.8
0.710.750.890.97
18.019.122.624.6
0.820.861.001.08
20.821.825.427.4
0.530.580.790.85
348436544684
403491611751
30282820
28242417
* These items are not CSA listed. CSA listing available as special order.Visit Okonite's web site, www.okonite.com for the most up to date dimensions.
Catalo
gNum
ber
Conductor Size
AWG
Number
of Conductors
Insu
latio
n
Thicknes
s - mils
CoreO.D
. -m
m
CoreO.D
. -In
ches
C-L-X
O.D. -
mm
C-L-X
O.D. -
Inch
es
Jack
etThick
ness - m
m
Jack
etThick
ness - m
ils
Approx.
O.D. -
mm
Approx.
O.D. -
Inch
es
Cross
-Sec
tional
Area (s
q. In.)
�
Approx.
ShipW
eight
lbs./
1000
’
90°C
Wet
or Dry(1
)
NECAm
pacity
75°C
Wet
NECAm
pacity
Approx.
NetW
eight
lbs./
1000
’
ULR
C-L-X Type MC (XHHW-2)600V Control Cable — Aluminum Sheath600/1000V Marine CableMultiple Copper Conductors /90°C Wet or Dry RatingFor Cable Tray Use - Sunlight Resistant - For Direct Burial
Conductor Color Coding SequenceConductor
Number Base Color Tracer Color1 Black2 Red3 Blue4 Orange5 Yellow6 Brown7 Red Black8 Blue Black9 Orange Black
10 Yellow Black11 Brown Black12 Black Red13 Blue Red14 Orange Red15 Yellow Red16 Brown Red17 Black Blue18 Red Blue19 Orange Blue20 Yellow Blue21 Brown Blue22 Black Orange23 Red Orange24 Blue Orange25 Yellow Orange26 Brown Orange27 Black Yellow28 Red Yellow29 Blue Yellow30 Orange Yellow31 Brown Yellow32 Black Brown33 Red Brown34 Blue Brown35 Orange Brown36 Yellow Brown37 Black
Special Order: Any or all of the following conductors may be added whenspecifically requested by the customer to meet his specific application re-quirements. These conductor codings comply with UL and NEC require-ments.
Purpose Base Color Tracer Color
Equipment Grounding UninsulatedGreenGreen 1 or more continuous
yellow stripes
Grounded WhiteWhiteWhiteWhiteWhite
WhiteWhite
Black continuous stripeRed continuous stripeBlue continuous stripeOrange continuousstripeBrown continuousstripeNumeric printing
Color Coding per ICEAMethod 1, E-2
Product DataSection 4: Sheet 14
ULR
F/15100414THE OKONITE COMPANY
Ramsey, New Jersey 07446
InsulationX-Olene® is Okonite's trade name for its chemi-cally cross-linked polyethylene, with high dielectricstrength.
Color CodingConductors are color coded using base colors andtracers in accordance with the Conductor Identifi-cation Table on the back of this Data Sheet.
Assembly and CoveringsThe individual conductors are cabled together withnon-hygroscopic fillers and a binder tape overall. TheC-L-X sheath exceeds the grounding conductor re-quirements of Table 250.122 of the NEC and UL1569.The impervious, continuous, corrugated aluminumC-L-X sheath provides complete protection againstmoisture, liquids and gases and has excellent me-chanical strength. For direct burial in the ground,embedment in concrete, or for areas subjected tocorrosive atmospheres, the C-L-X sheath is pro-tected with a low temperature black Okoseal® (PVC)jacket.
ApplicationsC-L-X Type MC cables with the impervious, con-tinuous, corrugated aluminum sheath arerecommended as an economical alternate to awire in conduit system.They are authorized for use on services, feedersand branch circuits for power, lighting, control andsignaling circuits in accordance with Articles 330and 725 of the NEC.C-L-X Type MC-HL cables may be installed in-doors or outdoors, in wet or dry locations, as openruns of cable secured to supports spaced notmore than six feet apart, in cable tray, as aerial ca-ble on a messenger, in any approved raceway,direct burial, or encased in concrete. C-L-X TypeMC-HL cables are also approved for Classes I, II,and III Division 1 and 2 and Class I, Zones 1 and 2hazardous locations per NEC Articles 501, 502,and 503 and UL 2225; in Zone Class II Div 2,Class III Div 1 and Class III Div 2 per CEC.
SpecificationsConductors: Bare soft annealed copper, Class Bstranding per ASTM B-8.
Insulation: X-Olene per ICEA S-73-532 and UL44, Listed UL Type XHHW-2. MeetsMIL-DTL-1377H, section 4.8.4.1.2, cold bend at-66°C and ASTM D746-04 brittle point at -40°C.
Conductor Identification: Base Colors and trac-ers.
Grounding Conductor: Green insulated strandedcopper per ASTM B-8, Class B. Meets or exceedsrequirements of NEC Table 250.122.
Assembly: Per UL 1569 with binder tape overall.
Sheath: Close fitting, impervious, continuous, corru-gated aluminum C-L-X per UL 1569.
Exceeds grounding conductor requirements ofNEC Table 250.122.
Jacket: Black Okoseal (PVC) per UL require-ments for Type MC-HL Cables. Meets ASTMD746-04 brittle point at -40°C.
Product Features• UL Listed as Type MC-HL cable and MarineShipboard Cable, E38916 (UL 1569) andE137931 (UL1309).
• UL Listed for cable tray use, direct burial andsunlight resistant.• UL 1309 listed (CWCMC) & UL classified inaccord with IEEE 1580 as Marine ShipboardCable rated 600/1000V
• CSA C22.2 No. 123 listed as RA90, FT4, HLand LTGG (-40°C).
• Passes the IEEE 383-1974 and IEEE 1202vertical tray flame tests.
• Passes the 210,000 BTU/hr ICEAT-29-520 Vertical Tray Flame Test.
• Complete pre-packaged, factory-tested wir-ing system — color coded.• C-L-X cables are quality control inspected tomeet or exceed applicable UL standards.
• 90°C continuous operating temperature in alltypes of installations.
• 130°C emergency rating
• 250°C short circuit rating.
• Good EMI shielding characteristics.
• Impervious, continuous metallic sheath ex-cludes moisture, gasses and liquids.
• Lower installed system cost than conduit orEMT systems.
• Provides excellent grounding safety.
• Excellent compression and impact resistance.
• Continuous long lengths.
• Installation temperature of -40°C or °F.
• Complies with NEC Articles 501, 502 and503 for hazardous locations.
• UL and American Bureau of Shipping listedas CWCMC Type MC-HL.
• CSA Type RA 90-HL complies with CECZone 1, Zone 2, Class II Div 2, Class III Div 1and Class III Div 2 Hazardous Locations.
C-L-X® Type MC-HL (XHHW-2)600V Control Cable — Aluminum Sheath600/1000V Marine CableMultiple Copper Conductors/90°C Wet or Dry RatingFor Cable Tray Use - Sunlight Resistant - For Direct Burial
Product DataSection 4: Sheet 15
A Bare, StrandedCopper Conductors
B X-Olene Insulation - ColorCoded for Identification
C Stranded copper, green insu-lated grounding conductor
D Marker TapeE Non-hygroscopic Fillers,
as necessaryF Binder TapeG Impervious, Continuous, Corru-
gated, Aluminum C-L-X SheathH Black Okoseal Jacket
ULR
A
B
F
G
E
H
D
C
C-H
L60
0V7/
C12
AW
G
� Authorized Stock Item - Available from our Service Centers.
Copper Or Bronze C-L-X is available on special order.
� Cross-sectional area for calculation of cable tray fill in accordance with NECSection 392.22.
Jacket - Optional jacket types available - consult local sales office.
(1) Ampacities are based on 310.15(B)(16) of the National Electrical Code forXHHW-2 conductors rated 90°C, in a multi-conductor cable, at an ambient temper-ature of 30°C (86F). The 75°C column is provided for additional information.The ampacities shown apply to open runs of cable, installation in any approvedraceway, direct burial in the earth, or as aerial cable on a messenger. Derating formore than three current carrying conductors within the cable is in accordance withNEC Section 310.15(B)(3)(a).The ampacities shown also apply to cables installed in cable tray in accordancewith NEC Section 392.80.
Product DataSection 4: Sheet 15
C-L-X Type MC-HL (XHHW-2)600V Control Cable—Aluminum Sheath600/1000V Marine CableMultiple Copper Conductors/90°C Wet or Dry RatingFor Cable Tray Use - Sunlight Resistant - For Direct Burial
� 546-31-3402� 546-31-3406� 546-31-3408 14(7X)
(2.08mm2)
268
#14 (7X)
0.300.410.49
7.610.412.4
0.490.620.71
12.415.818.0
50 1.27
0.600.730.82
15.218.520.8
0.280.420.53
163267321
202347401
151515
151414
*� 546-31-3411*� 546-31-3418*� 546-31-3436
111836
0.570.690.97
14.517.524.6
0.800.931.24
20.323.631.5
0.911.041.35
23.126.434.3
0.650.851.43
395554948
475634
1038
121210
1010
8
� 546-31-3452� 546-31-3456� 546-31-3458 12(7X)
(3.31mm2)
268
#12 (7X)
0.340.470.56
8.611.914.2
0.530.670.80
13.517.020.3
50 1.27
0.640.780.91
16.319.723.1
0.320.480.65
200338426
239418506
202020
201717
*� 546-31-3461*� 546-31-3468*� 546-31-3486
111836
0.650.781.10
16.519.827.9
0.891.021.37
22.625.934.8
1.001.131.48
25.428.737.6
0.791.001.72
519739
1302
599819
1445
151512
121210
� 546-31-3502� 546-31-3506 10(7X)
(5.26mm2)
26
#10 (7X)
0.390.54
9.913.7
0.580.75
14.719.1
50 1.27
0.690.86
17.521.8
0.370.58
253451
292531
3028
3024
� 546-31-3508*� 546-31-3511
811
0.650.75
16.519.1
0.890.97
22.624.6
1.001.08
25.427.4
0.790.92
568704
648784
2820
2417
* These items are not CSA listed. CSA listing available as special order.Visit Okonite's web site, www.okonite.com for the most up to date dimensions.
Catalo
gNum
ber
Conductor Size
AWG
Number
of
Ungrounded
Green
Insu
lated
Groundin
g
Conductor AW
G
CoreO.D
. -In
ches
CoreO.D
. -m
m
C-L-X
O.D. -
Inch
es
C-L-X
O.D. -
mm
Jack
etThick
ness - m
ils
Jack
etThick
ness - m
m
Approx.
O.D. -
Inch
es
Approx.
O.D. -
mm
Cross
-Sec
tional
Area (s
q. In.)
�
Approx.
NetW
eight
lbs./
1000
’
Approx.
ShipW
eight
lbs./
1000
’
90°C
Wet
or Dry(1
)
NECAm
pacity
75°C
Wet
NEC
Ampac
ity
ULR
C-L-X Type MC-HL (XHHW-2)600V Control Cable — Aluminum Sheath600/1000V Marine CableMultiple Copper Conductors /90°C Wet or Dry RatingFor Cable Tray Use - Sunlight Resistant - For Direct Burial
Conductor Color Coding SequenceUngroundedConductor
NumberBase Color Tracer Color
1 Black2 Red3 Blue4 Orange5 Yellow6 Brown7 Red Black8 Blue Black9 Orange Black
10 Yellow Black11 Brown Black12 Black Red13 Blue Red14 Orange Red15 Yellow Red16 Brown Red17 Black Blue18 Red Blue19 Orange Blue20 Yellow Blue21 Brown Blue22 Black Orange23 Red Orange24 Blue Orange25 Yellow Orange26 Brown Orange27 Black Yellow28 Red Yellow29 Blue Yellow30 Orange Yellow31 Brown Yellow32 Black Brown33 Red Brown34 Blue Brown35 Orange Brown36 Yellow Brown37 Black
Special Order: Any or all of the following conductors may be added whenspecifically requested by the customer to meet his specific application re-quirements. These conductor codings comply with UL and NEC require-ments.
Purpose Base Color Tracer Color
Equipment Grounding UninsulatedGreenGreen 1 or more continuous
yellow stripes
Grounded WhiteWhiteWhiteWhiteWhite
WhiteWhite
Black continuous stripeRed continuous stripeBlue continuous stripeOrange continuousstripeBrown continuousstripeNumeric printing
Product DataSection 4: Sheet 15
ULR
Color Coding per ICEAMethod 1, E-2
F/15100415 THE OKONITE COMPANYRamsey, New Jersey 07446
SpecificationsConductors: Bare soft annealed copper,Class B, 7-strand concentric per ASTM B-8.
Insulation: Flame-retardant Okoseal®
(PVC) per UL 13 and UL 2250, 15 milsnominal thickness, 105°C temperaturerating.
Conductor Identification: Pigmentedblack and white in pairs, black, red andwhite in triads.
Assembly: Pair or triad assembled with left-hand lay.
Cable Shield: Aluminum/synthetic polymertape overlapped to provide 100% coverage,and a 7-strand tinned copper drain wire,same size as conductor.
Jacket: Black, flame-retardant, lowtemperature Okoseal per UL 13 and UL2250. A rip cord is laid longitudinally underthe jacket to facilitate removal.
ClassificationsUL Listed as ITC/PLTC — Instrument TrayCable/Power Limited Tray Cable for use inaccordance with Article 727 and Article 725of the National Electrical Code.
These cables comply with UL 2250 and UL13 for PLTC, CL2, and CL3.
ApplicationsOkonite type P-OS (Pair/Triad - OverallShield) instrumentation cables are de-signed for use as instrumentation,process control, and computer cables inITC non-classified or labeled circuits upto 150 volts and 5 amps (750VA) and inClass 2 or 3 Power-Limited circuitswhere shielding against external inter-ference is required, but shieldingagainst interference among groups isnot required; indoors or outdoors; in wetor dry locations with conductor operat-ing temperatures up to 105°C; in cabletrays; in raceways; supported by a mes-senger wire. Suitable Class I, Division2, Class II, Division 2, or Class III, Divi-sion 2 hazardous locations. Also for use
as Power-Limited fire protectivesignaling cable (FPL) per NEC Code760.
The overall shield eliminates most ofthe static interference from the elec-tric field radiated by power cablesand other electrical equipment.
For dc service in wet locations, X-Olene®
insulation is recommended.
Product Features• Passes the UL 1581 & IEEE 383-1974 vertical tray flame tests.
• Sunlight resistant and oil resistant.
• Individual pairs or triads are colorcoded for simplified hook-up.
• Good noise rejection.
• Excellent weathering characteristics.
• OSHA Acceptable.
• Flexible, easy to handle and terminate.
• Twisted with 100% shield coverage toreduce electromagnetic noise pick-up.
• Suitable for low temperature installa-tion of -40°C.
Type P-OSType ITC/PLTC Instrumentation CableSingle Pair or Triad - Overall Shield300 Volts - 105°C RatingFor Cable Tray Use
A Bare Stranded CopperConductor
B Okoseal InsulationC Twisted Pair/TriadD Tinned Stranded Copper Drain WireE Aluminum/Polyester TapeF Rip CordG Black Okoseal Jacket
Product DataSection 5: Sheet 2
ULR
(UL
)T
YP
EIT
C/P
LT
C10
5°c
G
A
B
C
D
E
F
Okoseal Insulation 15 mils
264-10-1101264-15-1101 22
11 12
35
0.200.21
0.030.03
2226
2731
264-10-2201264-15-2201 20
11 12
0.220.23
0.040.04
2733
3238
� 264-10-3301� 264-15-3301 18
11 15
0.230.24
0.050.05
3543
4048
� 264-10-4401264-10-4901*
� 264-15-440116
11
115
0.250.250.26
0.050.050.06
474758
525259
* Tinned Copper Conductor
� Authorized Stock Item: Available from our Customer Service Center.
� Cross-sectional area for calculation of cable tray fill in accordancewith NEC Section 392-22
Length Tolerance: Cut lengths of 1000 feet or longer are subject to atolerance of � 10%; less than 1000 feet � 15%.
F/15040502
ULR
Type P-OSType ITC/PLTC Instrumentation CableSingle Pair or Triad - Overall Shield 300V - 105°C RatingFor Cable Tray Use
Product DataSection 5: Sheet 2
ELECTRICAL SPECIFICATIONSPer UL Standard 13 & 2250
Conductor Resistance, nominal .............ohms/1000 ft. @20°C
22 AWG ............................................................... 16.520 AWG................................................................. 10.318 AWG................................................................... 6.516 AWG................................................................... 4.1
Insulation Test Voltage (spark test) ..............5000 Volts ac
Dielectric Test Voltage.........................1500 Volts ac for 15 sec.
Insulation Resistance Constant @60°F minimum(natural material typical value)..............2000 Megohms-1000 ft.
Loop Resistance, nominal (2 conductor) ohms-1000 ft @20°C
22 AWG................................................................ 33.020 AWG................................................................ 20.818 AWG................................................................ 13.016 AWG................................................................. 8.2
Mutual Capacitance (PF/ft.)*
#22 ......................................................................... 34#20 ......................................................................... 37#18 ......................................................................... 41#16 ......................................................................... 44
*Typical Value
Cross
-Sec
tional
Area �
(sq
in)
Number
of Triads
Conductor Size
(AW
G)
Jack
etThick
ness-
(mils
)
Catalo
gNum
ber
Number
of Pairs
Approx Net
Weig
ht
(lbs/1
000’)
Approx Ship
Weig
ht
(lbs/1
000’)
Nomin
alCab
le
O.D. -
(In.)
Insu
latio
nThick
ness-
(mils
)
THE OKONITE COMPANYRamsey, New Jersey 07446
Bare soft annealed copper, ClassB, 7-strand concentric per ASTM B-8.
Flame-retardant Okoseal® (PVC)per UL Standard 13 and UL 2250, 15 milsnominal thickness, 105°C temperature rating.
Pigmented black andwhite in pairs, black, red and white in triads.
Pair or triad assembled with left-handlay.
Aluminum/Polyester tape over-lapped to provide 100% coverage, and a #18AWG, 7-strand tinned copper drain wire.
Black, flame-retardant Okosealper UL 13 and UL Standard 2250. A rip cord islaid longitudinally under the jacket to facilitate re-moval.
A close-fitting, impervious, con-tinuously welded and corrugated aluminumsheath provides complete protection againstmoisture, liquids, and gases, has excellent me-chanical strength and provides equipmentgrounding through the sheath.
Black, flame-retardant Okosealper UL 13 and UL Standard 2250.
UL Listed as ITC/PLTC — Instrument Tray Ca-ble/Power Limited Tray Cable for use inaccordance with Article 727 and Article 725 ofthe National Electrical Code.
These cables comply with UL 2250 and UL 13for PLTC, CL2 and CL3.
Okonite Type C-L-X P-OS (Pair/Triad - OverallShield) instrumentation cables are designed foruse as instrumentation, process control, andcomputer cables in ITC non-classified or labeledcircuits up to 150 volts and 5 amps (750VA) andin Class 2 or 3 Power-Limited circuits whereshielding against external interference is re-quired, but shielding against interference amonggroups is not required; indoors or outdoors; inwet or dry locations with conductor operatingtemperatures up to 105°C; in cable trays; inraceways; supported by a messenger wire; un-der raised floors; for direct burial. Suitable ClassI, Division 2, and Class I, Zone 2 Class II, Divi-sion 2, or Class III, Division 2 and Class I, Zone2 hazardous locations. Also for use asPower-Limited fire protective signaling cable(FPL) per NEC Code 760. The C-L-X sheath
provides physical protection against mechan-ical damage. It may be installed in bothexposed and concealed work, secured tosupports not greater than 6 feet apart.
The overall shield eliminates most of thestatic interference from the electric field radi-ated by power cables and other electricalequipment.
For dc service in wet locations, X-Olene® in-sulation is recommended.
• Passes the UL 1581, IEEE 383-1974, andIEEE 1202 vertical tray flame tests.
• Passes the 210,000 BTU/hr vertical trayflame test per ICEA T-29-520.
• UL listed as sunlight resistant.
• UL listed for direct burial.
• Complete pre-packaged, factory-testedwiring system-color coded.
• C-L-X enclosure permits installation in ca-ble tray containing light and power cableswithout a barrier separator.
• Individual pairs or triads are color codedfor simplified hook-up.
• Maximum noise rejection.
• Impervious, continuous sheath excludesmoisture, gases and liquids.
• C-L-X sheath exceeds equipment ground-ing conductor requirements of NEC Article250-118.
• Excellent compression and impact resis-tance.
• Lower installed system cost than conduitor EMT systems.
• OSHA Acceptable.
• Meets API Standards 14F and 14FZ.
• Suitable for low temperature installation of-40°C.
C-L-X® Type P-OS
Single Pair or Triad - Overall Shield300 Volts - 105°C Rating
Bare Stranded Copper ConductorOkoseal InsulationTwisted Pair/TriadTinned Stranded Copper Drain WireAluminum/Polyester TapeRip CordInner Black Okoseal JacketImpervious, Continuous CorrugatedAluminum C-L-X SheathOuter Black Okoseal Jacket
ULR
� 564-10-3401� 564-15-3401
11
3535
.26
.285050
.43
.43.54.54
.25
.25134155
173194
� : Available from our Customer Service Center
� area for calculation of cable tray fill in accordancewith NEC Section 392.22.
Optional jacket types available - consult local sales office.
C-L-X available on special order.
To order C-L-X Type P-OS without the outer Okoseal jacket, change thesixth digit of the catalog number from 3 to 1, for example to order 1 pr.16 AWG with a bare aluminum C-L-X, the catalog number would be564-10-1401.
C-L-X products manufactured in the United States under license grantedby Kabelmetal of Hanover, Germany.
Cut lengths of 1000 feet or longer are subject to atolerance of � 10%; less than 1000 feet � 15%.
J/15020503
ULR
C-L-X Type P-OSSingle Pair or Triad - Overall Shield 300V - 150°C Rating
Conductor Resistance, nominal .............ohms/1000 ft. @20°C
16 AWG................................................................... 4.1
Insulation Test Voltage (spark test) ..............5000 Volts ac
Dielectric Test Voltage....................................1500 Volts
Insulation Resistance Constant @60°F minimum(natural material typical value)..............2000 Megohms-1000 ft.
Loop Resistance, nominal (2 conductor) ohms-1000 ft @20°C
16 AWG................................................................. 8.2
Mutual Capacitance, typical .............................76 PF/ft.
�
THE OKONITE COMPANYRamsey, New Jersey 07446
Bare soft annealed copper,Class B, 7-strand concentric per ASTM B-8.
Flame-retardant Okoseal®
(PVC) per UL 13 and 2250, 15 mils nomi-nal thickness, 105°C temperature rating.
Pigmented blackand white in pairs, black, red and white in tri-ads; white conductor numerically printed forgroup identification.
Aluminum/Polyester tapeoverlapped to provide 100% coverage, anda 7-strand tinned copper drain wire, twosizes smaller than the conductor. All groupshields are completely isolated from eachother.
22 AWG, solid, barecopper conductor, 12 mils nominal flame-retardant Okoseal insulation, 105°C rating.
Pairs or triads assembled with aleft-hand lay. Flame-retardant, non-wicking fillersincluded where required to provide a round ca-ble.
Aluminum/Polyester tape over-lapped to provide 100% coverage, and a7-strand tinned copper drain wire, same sizeas conductor.
Black, flame-retardant, lowtemperature Okoseal per UL Subject 13 and2250. A rip cord is laid longitudinally under thejacket to facilitate removal.
UL Listed as ITC/PLTC - In-strument Tray Cable/Power Limited TrayCable for use in accordance with Article 727and Article 725 of the National ElectricalCode.
Cables comply with UL 2250 and UL 13 forPLTC, CL2 and CL3.
Okonite® Type SP-OS (Pair/triad - Individualand Overall Shield) instrumentation cables aredesigned for use as instrumentation, processcontrol, in ITC non-classified or labeled circuitsup to 150 volts and 5 amps (750VA) and inClass 2 or 3 Power-Limited circuits wheremaximum shielding against external interfer-ence is required, as well as shielding amonggroups, particularly where the cable may be
subject to abnormally high current or volt-age interference; indoors or outdoors; inwet or dry locations with conductor operat-ing temperatures up to 105°C; in cabletrays; in raceways; supported by a messen-ger wire; under raised floors. Suitable ClassI, Division 2, Class II, Division 2, or Class III,Division 2 hazardous locations. Also for useas Power-Limited fire protective signalingcable (FPL) per NEC Code 760.
The isolated individual shields overeach pair, when properly grounded,prevent crosstalk or capacitive cou-pling between adjacent pairs whichoccurs with ac signals, particularly thepulse type.
The overall shield eliminates most of thestatic interference from the electrical fieldradiated by power cables and other electri-cal equipment.
For dc service in wet locations, X-Olene®
insulation is recommended.
• Passes the UL 13 and IEEE 383-1974 ver-tical tray flame tests.
• Passes IEEE 1202 vertical tray flame test(8 pr #18 and 4 pr #16 & larger).
• Sunlight & oil resistant.
• Individual pairs or triads are completelyisolated.
• 100% shield coverage for reduced elec-tromagnetic noise pick-up.
• Good external noise rejection.
• Excellent weathering characteristics.
• OSHA Acceptable.
• Flexible, easy to handle and terminate.
• Communication wire included in each ca-ble for voice communication duringinstallation or instrument calibration.
• Suitable for low temperature installation of-40°C.
Type SP-OS
Multiple Shielded Pairs or Triads - Overall Shield300 Volts - 105°C Rating
Bare Stranded CopperConductorOkoseal InsulationTinned Stranded Copper GroupDrain WireAluminum/PolyesterTapeTwisted, Shielded Pairs/TriadsTinned Stranded Copper Drain WireAluminum/Polyester TapeCommunication WireRip CordBlack Okoseal Jacket
ULR
261-10-2202261-10-2204261-10-2206
20(7X) 15
246
405050
0.350.420.51
0.100.150.20
63103138
74126161
261-10-2208261-10-2210261-10-2212
81012
506060
0.530.660.66
0.250.340.37
169219248
193258287
261-10-2216261-10-2220261-10-2224
162024
606070
0.760.820.90
0.450.530.69
311374457
350413521
261-10-2236261-10-2250
3650
7070
1.061.23
0.881.19
632845
696951
261-15-2204261-15-2208261-15-2212
48
12
505060
0.480.620.77
0.180.300.47
126212314
149236353
261-15-2216261-15-2224261-15-2236
162436
607070
0.790.991.11
0.490.770.97
397587825
436651905
261-10-3302� 261-10-3304
261-10-3306
18(7X) 15
246
505050
0.380.470.57
0.110.190.25
89133181
112156205
� 261-10-3308261-10-3310
� 261-10-3312
81012
506060
0.560.730.69
0.290.420.44
223289330
247328369
261-10-3316261-10-3320
� 261-10-3324
162024
607070
0.830.940.98
0.540.690.85
417523614
456587678
� 261-10-3336261-10-3350
3650
7080
1.141.42
1.111.58
8611188
9411294
� 261-15-3304� 261-15-3308� 261-15-3312
48
12
506060
0.520.680.83
0.230.410.57
165301425
188340464
261-15-3316261-15-3324261-15-3336
162436
607070
0.891.101.24
0.620.951.21
543804
1143
607884
1249
� 261-10-4402� 261-10-4404
261-10-4406
16(7X) 15
246
505060
0.430.510.66
0.170.230.34
116179260
130203299
� 261-10-4408261-10-4410
� 261-10-4412
81012
606060
0.680.820.81
0.400.530.57
323397456
362436520
� 261-10-4416261-10-4420
� 261-10-4424
162024
707070
0.941.061.10
0.750.881.07
600729860
664809940
261-10-4436261-10-4450
3650
8080
1.371.57
1.471.93
12501687
13561830
261-15-4404� 261-15-4408� 261-15-4412
48
12
506070
0.550.740.93
0.260.480.74
227418615
251457679
261-15-4416261-15-4424261-15-4436
162436
708080
1.021.271.43
0.821.271.61
78811671668
85212731784
� Authorized Stock Item: Available from ourCustomer Service Center.
� area for calculation of cabletray fill in accordance with NEC Section 392.22
Cut lengths of 1000 feet orlonger are subject to a tolerance of � 10%; lessthan 1000 feet � 15%.
F/10030513
ULR
Type SP-OSMultiple Shielded Pairs or Triads - Overall Shield 300V - 105°C Rating
Conductor Resistance, nominal .............ohms/1000 ft. @20°C
20 AWG ............................................................... 10.418 AWG ................................................................. 6.516 AWG................................................................... 4.1
Insulation Test Voltage (spark test) ..............5000 Volts ac
Dielectric Test Voltage.........................1500 Volts ac for 15 sec.
Insulation Resistance Constant @60°F, minimum(natural material typical value)............. 2,000 Megohms-1000 ft.
Loop Resistance, nominal (2 conductor) ohms-1000 ft @20°C
20 AWG ............................................................... 20.818 AWG ............................................................... 13.016 AWG................................................................. 8.2
Mutual Capacitance (PF/ft.)*
20 AWG .................................................................. 5918 AWG................................................................... 6816 AWG................................................................... 76
*Typical Value
�
THE OKONITE COMPANYRamsey, New Jersey 07446
Bare soft annealed copper, Class B,7-strand concentric per ASTM B-8.
Flame-retardant Okoseal® (PVC) perUL 13 and 2250, 15 mils nominal thickness,105°C temperature rating.
Pigmented black andwhite in pairs, black, red and white in triads;white conductor numerically printed for groupidentification.
Aluminum/Polyester tape over-lapped to provide 100% coverage, and a 7-strandtinned copper drain wire, two sizes smaller than theconductor. All group shields are completely isolatedfrom each other.
22 AWG, solid, bare cop-per conductor, 12 mils nominal flame-retardantOkoseal insulation, 105°C temperature rating.
Pairs or triads assembled with left-hand lay. Flame-retardant, non-wicking fillers in-cluded where required to provide a round cable.
Aluminum/Polyester tape over-lapped to provide 100% coverage, and a 7-strandtinned copper drain wire, same size as conductor.
Black, flame-retardant, lowtemperature Okoseal per UL 13 and 2250. A ripcord is laid longitudinally under the jacket to facili-tate removal.
A close-fitting, impervious, continu-ously welded and corrugated, aluminum sheathprovides complete protection against moisture, liq-uids, and gases, has excellent mechanical strength,and provides equipment grounding through thesheath.
Black, flame-retardant, lowtemperature Okoseal per UL 13 and 2250.
UL Listed as ITC/PLTC - Instru-ment Tray Cable/Power Limited Tray Cable for usein accordance with Article 727 and Article 725 ofthe National Electrical Code.Cables comply with UL 2250 and UL 13 for PLTC,CL2 and CL3.
C-L-X Type SP-OS (Pair/triad - Individual andOverall Shield) instrumentation cables are de-signed for use as instrumentation, processcontrol, in ITC non-classified or labeled circuitsup to 150 volts and 5 amps (750VA) and inClass 2 or 3 Power-Limited circuits where max-imum shielding against external interference isrequired, as well as shielding among groups,particularly where the cable may be subject toabnormally high current or voltage interference;indoors or outdoors; in wet or dry locations withconductor operating temperatures up to 105°C;in cable trays; in raceways; supported by a
messenger wire; under raised floors or di-rect burial. Suitable in Class I & II, Division2 or Class III, Division 2 and Class I, Zone2 hazardous locations. Also for use asPower-Limited fire protective signaling ca-ble (FPL) per NEC Code 760. It may beinstalled in both exposed and concealedwork, secured to supports not greater than6 feet apart.The isolated individual shields over each pair,when properly grounded, prevent crosstalk orcapacitive coupling between adjacent pairswhich occurs with ac signals, particularly thepulse type.The overall shield eliminates most of the staticinterference from the electric field radiated bypower cables and other electrical equipment.The C-L-X sheath provides physical protectionagainst mechanical damage as well as com-plete protection against moisture or gasesentering the cable.For dc service in wet locations X-Olene® insula-tion is recommended.
• Passes the UL 13, IEEE 383-1974 vertical trayflame tests.• Passes the IEEE 1202 vertical tray flame test (2pr #18 AWG and larger).• Passes the 210,000 BTU/hr vertical tray flametest per ICEA T-29-520.• UL listed for direct burial (2 PR #20 AWG andlarger)• Complete pre-packaged, factory-tested wiringsystem-color coded.• C-L-X enclosure permits installation in cable traycontaining light and power cables without a barrierseparator.• Individual pairs or triads are completely iso-lated.• Impervious, continuous sheathexcludes moisture,gases and liquids.• C-L-X sheath exceeds equipment grounding con-ductor requirements of NEC Article 250-118.• Lower installed system cost than conduit orEMT systems.• Meets API Standards 14F & 14FZ.• Suitable for low temperature installation to -40°C.
C-L-X® Type SP-OS
Multiple Shielded Pairs or Triads - Overall Shield300 Volts - 105°C Rating
Bare Stranded Copper ConductorOkoseal InsulationTinned Stranded Copper GroupDrain WireAluminum/PolyesterTwisted, Shielded Pairs/TriadsCommunication WireAluminum/PolyesterTinned Stranded Copper Drain WireRip CordInner Black Okoseal JacketImpervious, Continuous, Corru-
gated Aluminum C-L-X SheathOuter Black Okoseal Jacket
ULR
561-10-3202561-10-3204561-10-3206
20(7X)
246
405050
0.360.430.48
0.580.620.71
505050
0.690.730.82
.37
.42
.53
198234286
217314366
561-10-3208561-10-3210561-10-3212
81012
505060
0.530.570.63
0.750.800.84
505050
0.860.911.95
.58
.65
.71
317393430
397473510
561-10-3216561-10-3220561-10-3224
162024
606070
0.720.810.90
0.971.061.15
505050
1.081.171.26
.921.081.25
501581704
581661794
561-10-3236561-10-3250
3650
7070
1.041.19
1.341.51
5060
1.451.65
1.652.14
9071230
10131373
561-15-3204561-15-3208561-15-3212
48
12
505060
0.450.560.67
0.670.800.89
505050
0.780.911.00
.48
.65
.79
258369504
338439584
561-15-3216561-15-3224561-15-3236
162436
607070
0.770.961.11
1.021.241.42
505050
1.131.351.53
1.001.431.84
604852
1117
684958
1260
� 561-10-3302� 561-10-3304
561-10-3306
18(7X)
246
405050
0.380.490.55
0.580.710.75
505050
0.690.820.86
0.370.530.58
212273338
292353418
� 561-10-3308561-10-3310
� 561-10-3312
81012
506060
0.600.670.71
0.800.890.93
505050
0.921.001.04
0.650.790.85
389479529
469559609
561-10-3316561-10-3320
� 561-10-3324
162024
606070
0.790.880.98
1.061.151.24
505050
1.171.261.35
1.081.251.43
632778889
738868995
561-10-3336561-10-3350
3650
7080
1.151.36
1.471.69
5060
1.581.82
1.962.60
12031629
13461812
561-15-3304561-15-3308561-15-3312
48
12
506060
0.540.690.79
0.750.931.06
505050
0.861.041.17
.58
.851.08
314475632
394555712
561-15-3316561-15-3324561-15-3336
162436
707080
0.901.061.29
1.151.341.60
505060
1.261.451.73
1.251.652.35
78110971539
86112401682
� 561-10-3402� 561-10-3404
561-10-3406
16(7X)
246
505050
0.440.520.59
0.670.710.84
505050
0.780.820.95
0.480.530.71
255327434
336407514
� 561-10-3408561-10-3410
� 561-10-3412
81012
606060
0.690.750.81
0.931.021.06
505050
1.041.131.17
0.851.001.08
505604671
585684777
561-10-3416561-10-3420
� 561-10-3424
162024
707070
0.951.031.10
1.241.341.37
505050
1.351.451.48
1.431.651.72
85510041245
94511011388
561-10-3436561-10-3450
3650
8080
1.291.53
1.601.87
6060
1.732.00
2.353.14
16782172
18422428
� 561-15-3404� 561-15-3408� 561-15-3412
48
12
506070
0.580.790.95
0.801.021.19
505050
0.911.131.30
0.651.001.33
384609862
464689952
561-15-3416561-15-3424561-15-3436
162436
708080
1.041.271.49
1.341.601.83
506060
1.451.731.96
1.652.353.02
105315742119
115917382306
� Authorized Stock Item: Available from our Cus-tomer Service Center.
Optional jacket types available - consultlocal sales office.� area for calculation of cabletray fill in accordance with NEC Section 392.22.Copper or bronze C-L-X available on special order.To order C-L-X Type SP-OS without the outerOkoseal jacket, change the sixth digit of the cata-log number from 3 to 1. For example, to order 12 pr.20 AWG with a bare aluminum C-L-X, the catalognumber would be 561-10-1212.C-L-X products manufactured in the United Statesunder license granted by Kabelmetal of Hannover,Germany.
Cut lengths of 1000 feet orlonger are subject to a tolerance of � 10%; lessthan 1000 feet � 15%.
H/14010514
ULRC-L-X Type SP-OSMultiple Shielded Pairs or Triads - Overall Shield 300V - 105°C Rating
Conductor Resistance, nominal .............ohms/1000 ft. @20°C20 AWG....................................................................... 10.418 AWG......................................................................... 6.516 AWG......................................................................... 4.1
Insulation Test Voltage (spark test) ..............5000 Volts acDielectric Test Voltage.........................1500 Volts ac for 15 sec.Insulation Resistance Constant @60°F minimum
(natural material typical value) ......2000 Megohms-1000 ft.Loop Resistance, nominal (2 conductor) ohms-1000 ft @20°C
20 AWG....................................................................... 20.818 AWG....................................................................... 13.016 AWG......................................................................... 8.2
Mutual Capacitance (PF/ft.)*#20 ................................................................................. 59#18 ................................................................................. 68#16 ................................................................................. 76
*Typical Value
�
THE OKONITE COMPANYRamsey, New Jersey 07446
SpecificationsConductors: Solid alloys per ANSI MC96.1Insulation: Flame-retardant Okoseal®
(PVC) per UL Standard 13 and 2250,15 mils nominal thickness, 105°C tem-perature rating.Conductor Identification: Pigmented in-sulation on individual conductors.Assembly: Pair assembled with left-hadlay.Cable Shield: Auminum/Polyester tapeoverlapped to provide 100% coverage,and a 7-strand tinned copper drain wire,same size as conductor.Jacket: Flame-retardant, low temperatureOkoseal per UL Standard 13 and 2250. Arip cord is laid longitudinally under thejacket to facilitate removal.Classifications: UL Listed as TypeITC/PLTC - Instrumentation Tray Ca-ble/Power Limited Tray Cable, for use inaccordance with Article 727 and 725 ofthe National Electrical Code.Cables comply with UL 2250 and ULSubject 13 for PLTC, CL2 and CL3.
ApplicationsOkonite Type P-OS (Pair/triad -Overall Shield) thermocoupleextension cables are designed for useas instrumentation and process con-trol cables in ITC non-classified orlabeled circuits up to 150 volts and 5amps (750VA) and in Class 2 of 3Power-Limited circuits where shieldingagainst external interference is re-quired, but shielding againstinterference among groups is not re-quired; indoors or outdoors; in wet ordry locations with conductor operatingtemperatures up to 105°C; in cabletrays; in raceways; supported by a
messenger wire; under raised floors;for direct burial. Suitable Class I, Divi-sion 2, Class II, Division 2, orClass III, Division 2 hazardous lo-cations.
Product Features• Passes the UL 1581 & IEEE 383-1974vertical tray flame tests.• Sunlight resistant & oil resistant..• UL listed for direct burial.• Individual pairs or triads are colorcoded for simplified hook-up.• Good noise rejection.• Excellent weathering characteristics.• OSHA Acceptable.• Flexible, easy to handle terminate.• Twisted with 100% shield coverage toreduce electromagnetic noise.• Suitable for lowtemperature installationof-40°C.
Type P-OSType ITC/PLTC Thermocouple Extension CableSingle Pair - Overall Shield - 105°C RatingFor Cable Tray Use
A Solid Thermocouple AlloyConductor
B Okoseal InsulationC Twisted Pair/TriadD Tinned Stranded Copper Drain WireE Aluminum/Polyester TapeF Rip CordG Okoseal Jacket
Product DataSection 5: Sheet 18
ULR
G
B
A
C
D
E
F
(UL
)T
YP
EIT
C/P
LT
C10
5°c
Conductors: 16 AWGOkoseal Insulation: 15 mils
EXJXKXTX
� 284-20-1401� 284-20-2401� 284-20-3401
284-20-4401
1111
35353535
.24
.24
.24
.24
.05
.05
.05
.05
44444444
49494949
� Authorized Stock Item: Available from our Cus-tomer Service Center.
SX available upon request.
(1) Special grade alloy conductors for JX and TXare available on special order.
� Cross-sectional area for calculation of cable trayfill in accordance with NEC Section 392.22
E/15040518
ULR
Type P-OSType ITC/PLTC Thermocouple Extension CableSingle Pair - Overall Shield - 105°C RatingFor Cable Tray Use
Product DataSection 5: Sheet 18
ELECTRICAL SPECIFICATIONSPer UL Standard 13 and 2250
Insulation Test Voltage (spark test) ..............5000 Volts ac
Dielectric Test Voltage.........................1500 Volts ac for 15 sec.
Shield Isolation TestPair to Cable Shield..........................exceeds 100M ohms/1000 ft.
Insulation Resistance Constant @60°F minimum(natural material typical value)..............2000 Megohms-1000 ft.
Cross
-Sec
tional
Area �
(sq
in)
Catalo
gNum
ber
Jack
etThick
ness-
(mils
)
ASA/ISA
Type
Number
of Pairs
Approx Net
Weig
ht
(lbs/1
000’)
Approx Ship
Weig
ht
(lbs/1
000’)
ASA/ISA COLOR CODE AND LIMITS OF ERROR
ASA/ISAType
Positive Wire Negative Wire OuterJacketColor
TemperatureRange°C
Limits of Error Nom. LoopResistance
Per 100’ @ 20°CAlloy Color Alloy Color Standard Special (1)
EX Chromel Purple Constantan Red Purple 0 to 200°C � 1.7°C 27.8 ohms
JX Iron White Constantan Red Black 0 to 200°C � 2.2°C � 1.1°C 13.9 ohms
KX Chromel Yellow Alumel Red Yellow 0 to 200°C � 2.2°C 23.6 ohms
TX Copper Blue Constantan Red Blue -60 to 100°C � 1.0°C � 0.5°C 12.0 ohms
Nomin
alCab
le
O.D. -
(In.)
THE OKONITE COMPANYRamsey, New Jersey 07446
Solid alloys per ANSI MC96.1.
Flame-retardant Okoseal®
(PVC) per UL Standard 13 and 2250,15 mils nominal thickness, 105°C tem-perature rating.
Pigmented in-sulating on individual conductors.
Pairs assembled with left-hand lay
Aluminum/Polyesterbacked tape overlapped to provide 100%coverage, and a 7-strand tinned copperdrain wire, same size as the conductor.
Black, flame-retardant, lowtemperature Okoseal per UL Standard 13and 2250. A rip cord is laid longitudinallyunder the jacket to facilitate removal.
Close fitting, impervious,continuously welded and corrugated alu-minum sheath provides completeprotection against moisture, liquids, andgases, has excellent mechanical strengthand provides equipment groundingthrough the sheath.
Flame-retardant, lowtemperature Okoseal per UL Standard 13and 2250.
UL Listed as TypeITC/PLTC - Instrumentation Tray Ca-ble/Power Limited Tray Cable, for use inaccordance with Article 727 and 725 ofthe National Electrical Code.
Cables comply with UL 2250 and UL Sub-ject 13 for PLTC, CL2 and CL3.
Okonite Type C-L-X P-OS (Pair/triad -Overall Shield) Thermocouple Extensioncables are designed for use as instrumen-tation and process control cables in ITCnon-classified or labeled circuits up to 150volts and 5 amps (750VA) and in Class 2or 3 Power-Limited circuits where shield-ing against external interference isrequired, but shielding against interfer-
ence among groups is not required;indoors or outdoors; in wet or dry loca-tion with conductor operatingtemperatures up to 105°C; in cabletrays; in raceways; supported by amessenger wire; under raised floors;for direct burial. Suitable Class I, Divi-sion 2, Class II, Division 2, or Class III,Division 2 and Class I, Zone 2 hazard-ous locations. The C-L-X sheathprovides physical protection againstmechanical damage. It may be in-stalled in both exposed and concealedwork, secured to supports not greaterthan 6 feet apart.
• Passes the UL 1581, IEEE 383-1974,& IEEE 1202 vertical tray flame tests.• Passes the 210,000 BTU/hr verticaltray flame test per ICEA T-29-520.• Complete pre-packaged, factory-testedwiring system-color coded.• C-L-X cables are quality control in-spected to meet or exceed applicable ULStandards.• C-L-X enclosure permits installation incable tray containing light and power ca-bles without a barrier separator.• Individual pairs or triads are colorcoded for simplified hook-up.• Impervious, continuous sheath ex-cludes moisture, gases and liquids.• C-L-X sheath exceeds equipmentgrounding conductor requirements ofNEC Section 250-118.• Lower installed system cost than conduit orEMT systems.• Meets API Standards 14F and 14FZ.• UL listed for direct burial• Suitable for low temperature installa-tion of -40°C
C-L-X® Type P-OS
Single Pair - Overall Shield - 105°C Rating
Solid Thermocouple AlloyConductorOkoseal InsulationTwisted PairTinned Stranded Copper Drain WireAluminum/Polyester TapeRip CordInner Okoseal JacketImpervious, Continuous, Corru-
gated Aluminum C-L-X SheathOuter Okoseal Jacket
ULR
EXJXKXTX
584-20-1401584-20-2401
� 584-20-3401584-20-4401
1111
35353535
.24
.24
.25
.24
.43
.43
.43
.43
50505050
.54
.54
.54
.54
.23
.23
.23
.23
128128128128
167167167167
� Available from our CustomerService Centers.
available upon request.
Special grade alloy conductors for JX and TX areavailable on special order.
� area for calculation of cable tray fillin accordance with NEC Section 392.22.
Optional jacket types available - consult lo-cal sales office.
available on special order.
To order C-L-X Type P-OS without the outer Okosealjacket, change the sixth digit of the catalog numberfrom 1 to 5 for EX, 2 to 6 for JX, 3 to 7 for KX, and 4 to8 for TX. For example to order 12 pr. 20 AWG TypeKX with a bare aluminum C-L-X, the catalog numberwould be 584-20-7212.
C-L-X products manufactured in the United States un-der license granted by Kabelmetal of Hanover,Germany.
Cut lengths of 1000 feet or longerare subject to a tolerance of � 10%; less than 1000feet � 15%.
J/14040519
ULR
C-L-X Type P-OS
Single Pair - Overall Shield - 105°C Rating
Insulation Test Voltage (spark test) .......................5000 Volts ac
Dielectric Test Voltage .........................1500 Volts ac for 15 sec.
Shield Isolation TestPair to Cable Shield.......................exceeds 100M ohms/1000 ft.
Insulation Resistance Constant @60°F, minimum(natural material typical value)...............2000 Megohms-1000 ft.
�
EX Chromel Purple Constantan Red Purple 0 to 200°C � 1.7°C 27.8 ohms
JX Iron White Constantan Red Black 0 to 200°C � 2.2°C � 1.1°C 13.9 ohms
KX Chromel Yellow Alumel Red Yellow 0 to 200°C � 2.2°C 23.6 ohms
TX Copper Blue Constantan Red Blue -60 to 100°C � 1.0°C � 0.5°C 12.0 ohms
THE OKONITE COMPANYRamsey, New Jersey 07446
SpecificationsConductors: Bare soft annealed copper,Class B, 7-strand concentric per ASTMB-8.
Insulation & Jacket: Flame-retardantOkoseal® (PVC), 15 mils nominal thick-ness, nylon jacket, 4 mil nominalthickness, 90°C temperature rating, perUL Standard 1277.
Conductor Identification: Pigmentedblack and white in pairs, black, whiteand red in triads.
Assembly: Pair or triad assembled withleft-hand lay.
Cable Shield: Aluminum/Polyester tapeoverlapped to provide 100% coverage,and a 7-strand tinned copper drain wire,same size as conductor.
Jacket: Black, flame-retardant, lowtemperature Okoseal per UL Standard1277, 90°C temperature rating. A rip cordis laid longitudinally under the jacket to fa-cilitate removal.
Classification: UL Listed as Type TC Ar-ticle 336 of the National Electrical Code.
ApplicationsOkonite’s single pair or triad Type P-OSinstrumentation cables are designed foruse on Class 1 Remote-Control Signalingcircuits or where a 600V cable is desired,as instrumentation, process control, orcomputer cable transmitting signals atlevels above 100 milli-volts in circuitswhere shielding against external interfer-ence is required, but shielding againstinterference among groups is not re-quired. For use indoors or outdoors; wetor dry locations; in cable trays; in race-ways; supported by a messenger wire; inClass I, Division 2, Class II, Division 2 orClass III, Division 2 hazardous locations.Also for use as non power limited fire pro-tective signaling cable (NPLF) per NECCode 760. Type TC cables can be labeledOkomarine to be used in ABS and CoastGuard approved marine applications.
Type TC is authorized for use inClass I & II, Division 2 hazardouslocations.
Product Features• Passes the UL 1277 & IEEE 383-1974 vertical tray flame tests.
• May be combined with 600V powerand control cables in the same tray.
• Sunlight resistant & oil resistant
• Individual pairs or triads are colorcoded for simplified hook-up.
• Good noise rejection.
• Excellent weathering characteristics.
• May be used in approved marine ap-plications.
• Flexible, easy to handle and ter-minate.
• Twisted with 100% shield coverageto reduce electromagnetic pick-up.
• OSHA Acceptable.
• Suitable for installation in low tem-perature installations to -40°C.
Okoseal-N® Type P-OSType TC Instrumentation CableSingle Pair or Triad - Overall Shield600 Volts - 90°C Rating Wet or Dry
A Stranded Bare Copper ConductorB Okoseal Insulation with Nylon
JacketC Twisted Pair/TriadD Stranded Tinned Copper Drain WireE Aluminum/Synthetic Polymer TapeF Rip CordG Black Okoseal Jacket
Product DataSection 5: Sheet 29
ULR
E
ABC
D
FG
(UL
)T
YP
ET
C90
°cD
RY
AN
D75
°CW
ET
Okoseal Insulation: 15 milsNylon Jacket: 4 mils
� 264-60-3301264-65-3301
1818
11
45
0.270.29
0.060.07
4854
5359
� 264-60-4401� 264-65-4401
1616
11
0.290.31
0.070.08
5669
6180
� 264-60-5501264-65-5501
1414
11
0.320.34
0.090.10
7594
86105
� Cross-sectional area for calculation of cable tray fill inaccordance with NEC Section 392-22
Length Tolerance: Cut lengths of 1000 feet or longer aresubject to a tolerance of � 10%; less than 1000 feet � 15%.
� Authorized Stock Item: Available from our CustomerService Centers.
G/15090529
ULR
Okoseal-N Type P-OSType TC Instrumentation CableSingle Pair or Triad - Overall Shield600V - 90°C Rating Wet or Dry
Product DataSection 5: Sheet 29
ELECTRICAL SPECIFICATIONSPer UL Standard 1277
Conductor Resistance, maximumohms/1000 ft.. . . . . . . . . . . . . . . . . . . . . . . . . . . . @20°C ..........@25°C
18 AWG . . . . . . . . . . . . . . . . . . . . 6.09···············7.0416 AWG . . . . . . . . . . . . . . . . . . . . 4.34···············4.4314 AWG . . . . . . . . . . . . . . . . . . . . . 2.72···············2.78
Insulation Test Voltage (spark test)
18 - 16 AWG . . . . . . . . . . . . . . 6000 volts ac14 AWG . . . . . . . . . . . . . . . . . . 7500 volts ac
Dielectric Test Voltage
18-16 AWG . . . . . . . . . . . . . . . 1500 volts ac for 1 minute14 AWG . . . . . . . . . . . . . . . . . . 2000 volts ac for 1 minute
Shield Isolation Test
Pair to Cable Shield . . . exceeds 100 Megohms/1000 ft.
Insulation Resistance Constant @60°F minimum(natural material typical value) ..........2000 Ohms-1000 ft.
Loop Resistance, nominal (2 conductor)ohms-1000 ft. . . . . . . . . . . . . . . . . . . . . . . . . . . . @20°C ..........@25°C
18 AWG . . . . . . . . . . . . . . . . . . . 12.18·············14.0816 AWG . . . . . . . . . . . . . . . . . . . . 8.68···············8.8614 AWG . . . . . . . . . . . . . . . . . . . . 5.44···············5.56
Cross
-Sec
tional
Area �
(sq
in)
Number
of Triads
SizeAW
G
Catalo
gNum
ber
Number
of Pairs
Approx Net
Weig
ht
(lbs/1
000’)
Approx Ship
Weig
ht
(lbs/1
000’)
Nomin
alCab
le
O.D. -
(In.)
Jack
etThick
ness-
(mils
)
Mutual Capacitance 18 AWG ......................49 pF/ft16 AWG ......................56 pF/ft14 AWG ......................64 pF/ft
L/R ratio 18 AWG ......................14 micro Henry/ohm16 AWG ......................21 micro Henry/ohm14 AWG ......................31 micro Henry/ohm
Inductance 18 AWG ......................0.19 micro Henry/ft16 AWG ......................0.18 micro Henry/ft14 AWG ......................0.17 micro Henry/ft
THE OKONITE COMPANYRamsey, New Jersey 07446
Bare soft annealed copper,Class B, 7-strand concentric per ASTM B-8.
Flame-retardant Okoseal®
(PVC), 15 mils nominal thickness, nylonjacket, 4 mil nominal thickness, 90°C tem-perature rating, per UL Standard 1277.
Pigmented blackand white in pairs; black, white and redin triads.
Aluminum/Polyester tape over-lapped to provide 100% coverage, and a7-strand tinned copper drain wire, two sizessmaller than the conductor. All group shieldsare completely isolated from each other.
Pairs or triads assembled with1 left-hand lay. Flame-retardant, non-wickingfillers included where required to provide around cable.
Aluminum/Polyester tape over-lapped to provide 100% coverage, and a7-strand tinned copper drain wire, same sizeas conductor.
Black, flame-retardant, lowtemperature Okoseal per UL Standard 1277,90°C temperature rating. A rip cord is laid lon-gitudinally under the jacket to facilitateremoval.
UL Listed as Type TC Article336 of the National Electrical Code.
Okonite’s Type SP-OS (Shielded pairs or tri-ads - Overall Shield) instrumentation cablesare designed for use on Class 1 Remote-Control Signaling circuits or where a 600V ca-ble is desired, as instrumentation, processcontrol, or computer cable transmitting signalsat levels above 100 mili-volts in circuits wheremaximum noise protection is required. Protec-tion from interference among groups as well asexternal sources is provided by individualgroup shields as well as an overall cableshield. For use indoors or outdoors; wet or drylocations; in raceways; supported by a mes-senger wire; for direct burial; in Class I,Division 2, Class II, Division 2 or Class III, Di-vision 2 hazardous locations. Also for use asnon power limited fired protective signaling ca-ble (NPLF) per NEC Code 760. As an option,type TC cables can be labeled Okomarine tobe used in ABS and Coast Guard approvedmarine applications, on special order.
• Passes the UL 1277 and IEEE 383-1974vertical tray flame tests.
• Passes IEEE 1202 vertical tray flame test(8 pr #18 and 4 pr #16 & larger).
• May be combined with 600 volt powerand control cables in the same tray.
• Sunlight resistant and oil resistant.
• UL listed for direct burial (8/pr #16 AWGand larger)
• Individual pairs or triads are numberedand color-coded for simplified hook-up.
• Individual pairs or triads are completelyisolated.
• 100% shield coverage for reduced elec-tromagnetic noise pick-up.
• Good external noise rejection.
• Excellent weathering characteristics.
• OSHA Acceptable.
• Flexible, easy to handle and termi-nate.
• Suitable for installation at low tem-peratures to -40°C.
Okoseal-N® Type SP-OS
Multiple Shielded Pairs or Triads - Overall Shield600 Volts - 90°C Rating Wet or Dry ULR
Stranded Bare Copper ConductorOkoseal Insulation with NylonJacketTinned Stranded Copper GroupDrain WireDouble Faced Aluminum/SyntheticPolymer Backed TapeTwisted, Shielded Pairs/TriadsDouble Faced Aluminum/SyntheticPolymer Backed TapeStranded Tinned Copper Drain WireRip CordBlack Okoseal Jacket
261-60-3304261-60-3308
18 (7x)
48
4560
0.500.67
0.200.35
138258
161297
261-60-3310261-60-3312261-60-3316
101216
608080
0.770.810.93
0.460.510.67
316395496
355459559
261-60-3320261-60-3324261-60-3336261-60-3350
20243650
80808080
1.071.091.281.55
0.900.931.291.89
597699974
1307
677779
10801450
261-65-3304261-65-3308261-65-3312
48
12
606080
0.610.750.95
0.290.440.71
196317516
220356580
261-65-3316261-65-3324261-65-3336
162436
808080
1.091.341.53
0.931.411.84
652940
1319
73210461462
� 261-60-4402� 261-60-4404� 261-60-4408
16 (7x)
248
456060
0.440.580.72
0.150.260.47
114198337
137222376
261-60-4410� 261-60-4412
261-60-4416
101216
808080
0.940.911.04
0.690.650.85
452515650
516579730
261-60-4420� 261-60-4424
261-60-4436261-60-4450
20243650
808080
110
1.191.181.401.79
1.111.091.542.52
787925
13041866
867103114102053
261-65-4404� 261-65-4408� 261-65-4412
48
12
608080
0.610.791.00
0.290.490.79
252478674
291542754
261-65-4416261-65-4424261-65-4436
162436
808080
1.121.501.71
0.991.772.30
85812451761
96413881948
261-60-5504261-60-5508
14 (7x)
48
6080
0.680.91
0.360.65
272511
311575
261-60-5510261-60-5512261-60-5516
101216
808080
1.061.091.20
0.880.931.13
627721919
707801
1025
261-60-5520261-60-5524261-60-5536261-60-5550
20243650
808080
110
1.341.481.672.02
1.411.722.193.20
1120132218862681
1226142820292973
261-65-5504261-65-5512
412
6080
0.751.23
0.441.19
351954
3901060
261-65-5516261-65-5524261-65-5536
162436
8080
110
1.361.692.00
1.452.243.14
122517942683
133119872975
� area for calculation of cable tray fill inaccordance with NEC Section 392.22
Cut lengths of 1000 feet or longer aresubject to a tolerance of � 10%; less than 1000 feet � 15%.
� Available from our CustomerService Centers.
F/14090531
ULR
Okoseal-N Type SP-OSSingle Pairs or Triads - Individual and Overall Shield600V - 90°C Rating Wet or Dry
Conductor Resistance, maximum ........ohms/1000 ft................................................................... @20°C @25°C
18 AWG ................................................ 6.09 7.0416 AWG ................................................ 4.34 4.4314 AWG ................................................ 2.72 2.78
Insulation Test Voltage (spark test)18 - 16 AWG .................... 6000 VOLTS AC14 AWG ........................... 7500 VOLTS AC
Dielectric Test Voltage ...............2000 Volts ac for 1 minuteInsulation Resistance Constant @ 60F, minimum
(natural material typical value) ............ 2000 ohms/1000 ft.Loop Resistance, maximum (2 conductor)ohms-1000 ft.................................................................. @20°C @25°C
18 AWG............................................... 12.18 14.0816 AWG ............................................... 8.68 8.8614 AWG .............................................. 5.44 5.56
�
THE OKONITE COMPANYRamsey, New Jersey 07446
SpecificationsConductors: Bare soft annealed copper, ClassB, 7-strand concentric per ASTM B-8.Insulation: Flame-retardant Okoseal (PVC)per UL 83, 15 mils nominal thickness, 90°Ctemperature rating.Jacket: Nylon per UL 83, 4 mils nominal thickness.Conductor Identification: Pigmented black andwhite in pairs; black, white and red in triads.Assembly: Pairs or triads assembled with left-hand lay. Non-wicking fillers included where re-quired to provide a round cable.Cable Shield: Aluminum/Polyester tape over-lapped to provide 100% coverage, and a #16AWG stranded tinned copper drain wire.Inner Jacket: Black, flame-retardant Okosealper UL Standard 1569. A rip cord is laid longitu-dinally under the jacket to facilitate removal.C-L-X Sheath: A close-fitting, impervious, con-
tinuously welded and corrugated, aluminum
sheath meeting UL 1569 provides complete pro-
tection against moisture, liquids, and gases, has
excellent mechanical strength, and provides
equipment grounding through the sheath.
Outer Jacket: Black, flame-retardant Okosealper UL Standard 1569.
ApplicationsOkonite C-L-X Single pair or triad type P-OS in-
strumentation cables are designed for use on
Class 1 Remote-Control Signaling circuits or
where a 600V cable is desired, as instrumenta-
tion, process control, or computer cable
transmitting signals at levels above 100
milli-volts in circuits where shielding against ex-
ternal interference is required, but shielding
against interference among groups is not re-
quired. For use indoors or outdoors; wet or dry
locations; in cable trays; in raceways; supported
by a messenger wire; for direct burial; in Classes
I, II, and III, Divisions 1 and 2 hazardous loca-
tions per NEC Articles 501, 502, 503, 504 and
505; in Zone 2, Class II Div 2, Class III Div 1 and
Class III Div 2 per CEC.
The overall shield eliminates most of the staticinterference from the electric field radiated bypower cables and other electrical equipment.The C-L-X sheath provides the physical protec-tion against mechanical damage as required inNEC Section 725-8 as well as complete protec-tion against moisture or gases entering thecable.
For dc service in wet locations, X-Olene insu-lation is recommended.These cables also comply with UL require-ments for Types CL2 and CL3.
Product FeaturesComplete pre-packaged, factory-tested wir-ing system—color coded.C-L-X enclosure permits installation in cabletray containing light and power cables with-out a barrier separator.Impervious, continuous sheath excludesmoisture, gases and liquids.C-L-X sheath exceeds equipment groundingconductor requirements of NEC Section250-122, for Non-HL locations.Excellent compression and impact resis-tance.Lower installed system cost than conduit orEMT systems.Suitable for low temperature installation to-40°C.
Applicable Standards• UL listed for cable tray use, direct burialand sunlight resistant.• Vertical Tray Flame Tests.
IEEE 383-1974, FT4/IEEE 1202,ICEA T-29-520 (210,000 BTU)
• American Bureau of Shipping Type ap-proved as CWCMC Type MC-HL.• API Standards 14F and 14FZ.• ASTM B-8.• OSHA Acceptable• UL 2225 Type MC-HL• UL 83• UL 1309 (CWCMC) Marine Shipboard• UL 1569• UL certified as Marine Shipboard in ac-cord with IEEE 1580, Marine ShipboardCable rated 600/1000 volts.• NEC Articles 501, 502, 503, 504 and 505for Classes I, II and III, Divisions 1 and 2Hazardous Locations.• NPLF per NEC Code Article 760.• CSA C22.2 No. 230 Type TC• CSA C22.2 No. 239 Type ACIC• cUL Type ACIC-TC complies with CECZone 2, Class II Div 2, Class III Div 1 andClass III Div 2 Hazardous Locations.
C-L-X® Okoseal-N® P-OSUL Type MC-HL and cUL Type ACIC-TC Instrumentation CableSingle Pair or Triad-Overall Shield600 Volts 90°C Rating 600/1000V Marine CableFor Cable Tray Use - Sunlight Resistant - For Direct Burial
A Bare Stranded CopperConductor
B Okoseal Insulation/Nylon JacketC Twisted, Shielded Pairs/TriadsD Tinned Stranded Copper Drain WireE Aluminum/Synthetic Polymer TapeF Rip CordG Inner Black Okoseal JacketH Impervious, Continuous, Corrugated
Aluminum C-L-X SheathJ Outer Black Okoseal Jacket
Product DataSection 5: Sheet 40
ULR
E
AB
C
D
FG
H
J
P-O
S1P
R16
AW
GC
UP
VC
-NP
VC
(UL)
c ULR
� Authorized Stock Item: Available from our Customer Service Centers.
* area for calculation of cable tray fill in accordance withNEC Section 392.22.
Optional jacket types available - consult local sales office.
C-L-X available on special order.
r C-L-X Type P-OS without the outer Okoseal jacket (not “HL”listed), change the sixth digit of the catalog number from 3 to 1, for exam-ple to order 1 pr. 20 AWG with a bare aluminum C-L-X, the catalog numberwould be 564-10-1212.
Cut lengths of 1000 ft. or longer are subject to a toler-ance of � �\ 10%; less than 1000 ft. � �\ 15%
K/15020540
C-L-X Okoseal-N P-OSSingle Pair or Triad-Overall Shield600 Volts 90°C Rating 600/1000V Marine Cable
Conductors: #16 AWG; Okoseal Insulation: 15 mils: Nylon Jacket: 4 mils
-
Conductor Resistance, maximum .......................ohms/1000 ft.............................................................................@20°C @25°C
16 AWG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.34 4.43Insulation Test Voltage (spark test).....................6000 Volts acDielectric Test Voltage ........................................2000 Volts ac.Shield Isolation Test
Pair to Cable Shield . . . . . . . . . exceeds 100 Megohms-1000 ft.Insulation Resistance Constant @60°F minimum
(natural material typical value) . . . . . . 2000 Ohms-1000 ft.Loop Resistance, nominal (2 conductor).............ohms/1000 ft............................................................................@20°C @25°C
16 AWG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.68 8.86Mutual Capacitance (PF/ft.)*
#16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60*Typical Value
� 564-60-3401� 564-65-3401
11
6658
.35
.35.53.53
5050
.64
.640.320.32
182190
221229
THE OKONITE COMPANYRamsey, New Jersey 07446
ULR c ULR
SpecificationsConductors: Bare soft annealed copper, Class B,7-strand concentric per ASTM B-8.Insulation: Flame-retardant Okoseal (PVC) perUL 83, 15 mils nominal thickness, 90°C tem-perature rating.Insulation Jacket: Nylon per UL 83, 4 mils nominalthickness.Conductor Identification: Pigmented black andwhite in pairs, black, white and red in triads.Group Shield: Aluminum polyester tape over-lapped to provide 100% coverage, and a 7-strandtinned copper drain wire, two sizes smaller thanthe conductor. All group shields are completelyisolated from each other.Assembly: Pairs or triads assembled with left-handlay. Non-wicking fillers included where required toprovide a round cable.Cable Shield: Aluminum/polyester tape over-lapped to provide 100% coverage, and a 7-strandtinned copper drain wire, same size as conductor.Inner Jacket: Black, flame-retardant Okoseal perUL Standard 1569. A rip cord is laid longitudinallyunder the jacket to facilitate removal.C-L-X Sheath: A close-fitting, impervious, contin-uously welded and corrugated, aluminum sheathprovides physical protection against mechanicaldamage as required in NEC Section 725-8.Additionaly, C-L-X meets UL 1569 provides com-plete protection against moisture, liquids, andgases, has excellent mechanical strength, andprovides equipment grounding through the sheath.Outer Jacket: Black, flame-retardant Okoseal perUL Standard 1569.Classifications: UL Listed as Type MC-HL Arti-cles 501, 502, and 503 of the National ElectricalCode.
ApplicationsOkonite C-L-X type SP-OS (shielded pairs or tri-ads - overall shield) instrumentation cables aredesigned for use on Class 1 Remote-Control Sig-naling circuits or where a 600V cable is desired,as instrumentation, process control, or computercable transmitting signals at levels above 100mili-volts in circuits where maximum noise protec-tion is required. Protection from interferenceamong groups as well as external sources is pro-vided by individual group shields as well as anoverall cable shield. For use indoors or outdoors;wet or dry locations; in cable trays’ in raceways;supported by a messenger wire; for direct burial;in Classes I, II, and III, Divisions 1 and 2 andClass I, Zones 1 and 2 hazardous locations perNEC Articles 501, 502, 503 and 505; in Zone 2,
Class II Div 2, Class III Div 1 and Class III Div2 per CEC.The isolated individual shields over eachpair, when properly grounded, preventcrosstalk or capacitive coupling betweenadjacent pairs which occurs with ac signals,particularly the pulse type.The overall shield eliminates most of the staticinterference from the electric field radiated bypower cables and other electrical equipment.The C-L-X sheath provides physical protectionagainst mechanical damage as required inNEC Section 725-8 as well as complete pro-tection against moisture or gases entering thecable.For dc service in wet locations, X-Olene insu-lation is recommended.
Product FeaturesIndividual units are completely isolated formaximum noise rejection.C-L-X enclosure permits installation in cabletray containing light and power cables withouta barrier separator.C-L-X sheath exceeds equipment groundingconductor requirements of NEC Section250-122, non-HL locations.Lower installed system cost than conduit orEMT systems.Suitable for low temperature installation to-40°C.
Applicable Standards• UL listed for cable tray use, direct burial, inducts, and sunlight resistant.• Vertical Tray Alame Tests;IEEE 383-1974, FT4/ IEEE 1202, ICEAT-29-520 (210,000 BTU).• American Bureau of Shipping Type approvedas CWCMC Type MC-HL.• API Standards 14F and 14FZ.• ASTM B-8• OSHA Acceptable• UL 2225 Type MC-HL, UL 83, UL 1309(CWCMC) Marine Shipboard, UL 1569• UL certified to IEEE 1580 - Marine Ship-board Cable rated 600/1000V.• NEC Articles 501, 502, 503, 504 and 505 forClasses I, II, and III, Divisions 1 and 2 Hazard-ous Locations.• NPLF pr NEC Code Article 760.• CSA C22.2 No. 230 Type TC• CSA C22.2 No. 239 Type ACIC• cUL Type ACIC-TC Complies with CECZone 2, Class II Div 2, Class III Div 1, Class IIIDiv 2 Hazardous Locations.
C-L-X® Okoseal-N® SP-OSUL Type MC-HL and cUL Type ACIC-TC Instrumentation CableMultiple Shielded Pairs or Triads - Individual and Overall Shield600 Volts 90°C Rating MC-HL — 600/1000V Marine CableFor Cable Tray Use - Sunlight Resistant - For Direct Burial
Product DataSection 5: Sheet 42
A Bare Stranded CopperConductor
B Okoseal Insulation/Nylon JacketC Tinned Stranded Copper Group
Drain WireD Aluminum/Polyster TapeE Twisted, Shielded Pairs/TriadsF Tinned Stranded Copper Drain WireG Aluminum/Polyester TapeH Rip CordJ Inner Black Okoseal JacketK Impervious, Continuous, Corrugated
Aluminum C-L-X SheathL Outer Black Okoseal Jacket
SP
-OS
24P
R16
AW
GC
UP
VC
-NP
ULR c ULR
� 561-60-3402� 561-60-3404
561-60-3406
246
405050
0.450.560.66
0.670.800.89
505050
0.760.911.00
0.450.650.79
234335421
314415501
� 561-60-3408561-60-3410
� 561-60-3412
81012
505050
0.700.790.85
0.931.061.11
505050
1.041.171.22
0 .851.081.17
492601674
572681780
561-60-3416561-60-3420
� 561-60-3424
162024
505050
0.981.061.12
1.291.341.42
505050
1.401.451.53
1.541.651.84
842977
1118
94811201261
� 561-60-3436561-60-3450
3650
5050
1.371.57
1.691.92
6060
1.822.05
2.603.30
15862124
17732416
� 561-65-3404� 561-65-3408� 561-65-3412
4812
505050
0.610.820.98
0.841.061.29
505050
0.951.171.40
0.711.081.54
395637863
475717969
561-65-3416561-65-3424561-65-3436
162436
505050
1.101.331.58
1.371.641.96
506060
1.481.782.09
1.722.493.43
105814852141
120116722426
� Available from our Customer Service Centers.
* for calculation of cable tray fill in accordance withNEC Section 392.22.
Optional jacket types available - consult local sales office.
available on special order.
To order C-L-X Type SP-OS without the outer Okoseal jacket (not “HL”listed), change the sixth digit of the catalog number from 3 to 1, for exam-ple to order 1 pr. 20 AWG with a bare aluminum C-L-X, the catalog numberwould be 564-10-1212.
Cut lengths of 1000 ft. or longer are subject to a toler-ance of � �\ 10%; less than 1000 ft. � �\ 15%
K/14120542
C-L-X Okoseal-N SP-OS
Multiple Shielded Pairs or Triads - Individual and Overall Shield600V 90°C Rating MC-HL — 600/1000V Marine Cable
Conductors: #16 AWG; Okoseal Insulation: 15 mils: Nylon Jacket: 4 mils
Conductor Resistance, nominal ........................ohms/1000 ft. @20°C16 AWG......................................................................4.1
Insulation Test Voltage (spark test) ...............................6000 Volts acDielectric Test Voltage .................................2000 Volts ac for 60 sec.Insulation Resistance Constant @60°F minimum
(natural material typical value) ..2000 Megohms-1000 ft.Loop Resistance, nominal (2 conductor)............ohms-1000 ft @20°C
16 AWG......................................................................8.2Mutual Capacitance (PF/ft.)*
#16 ..............................................................................60*Typical Value
THE OKONITE COMPANYRamsey, New Jersey 07446
ULRc ULR
#18 AWG tinned copper,Class M, stranded per ASTM B-174.
Okolene® (Polypropylene)per UL 13 and 2250, 32 mils nominalthickness, 75°C temperature rating.
Pigmented or-ange and blue in pairs, orange conductornumerically printed for group identification.
Aluminum/Polyester tapeoverlapped to provide 100% coverage,and a Class M tinned copper drain wire,two sizes smaller than the conductor. Allmulti-pair shields are isolated from eachother.
Pairs assembledwith a left-hand lay. Cable fillers includedwhere required to provide a round cable.
Alumi-num/Polyester tape overlapped to provide100% coverage, and a class M strandtinned copper drain wire, same size asconductor.
Orange, flame-retardant, Okosealper UL 13 and 2250. A rip cord is laid lon-gitudinally under the jacket to facilitateremoval.
UL Listed asPLTC-Power Limited Tray Cable and asITC-ER - Instrument Tray Cable/ExposedRun for use in accordance with Article 727and Article 725 of the National ElectricalCode.
Cables comply with ISA-S-50-02, UL 2250and UL 13 for Fieldbus circuits and CL2and CL3.
Okonite® OKOBUS® cables are designedfor use in rugged plant environments utiliz-ing networked discrete or processautomation and control. ITC-ER (Instru-ment Tray Cable - Exposed Run)eliminated the need for conduit when in-stalled in accordance with NEC Article727.4(6). Fully complies with ANSI/ISA50.02 part 2 for Fieldbus Cable.
The isolated individual shields overeach pair, when properly grounded,
prevent crosstalk or capacitive cou-pling between adjacent pairs whichoccurs with ac signals, particularlythe pulse type.
The overall shield or multi pair cableseliminates most of the static interferencefrom the electrical field radiated by powercables and other electrical equipment.
• Passes the UL 13 and IEEE 383 verticaltray flame tests.
• Single pair passes IEEE 1202 verticaltray flame test.
• Sunlight & oil resistant.
• UL listed for direct burial.
• Individual pairs are completely isolated.
• 100% shield coverage for reduced elec-tromagnetic noise pick-up.
• Excellent external noise rejection.
• Excellent weathering characteristics.
• OSHA Acceptable.
• Flexible, easy to handle and terminate.
Tinned Copper StrandedConductorPolypropylene InsulationTinned Stranded Copper GroupDrain WireAluminum/Polyester TapeTwisted, Shielded PairsAluminum/Polyester TapeTinned Stranded Copper DrainWireRip CordOrange Okoseal Jacket
Okobus
Single Pair or Multiple Shielded Pairs - Overall Shield300 Volts 75°C Rating
ULR
� 264-92-3901261-92-3302
12
4550
0.340.55
0.090.24
62148
73172
261-92-3304261-92-3063
46
6060
0.710.80
0.400.50
212264
251303
261-92-3308261-92-3312261-92-3316
81216
707070
0.911.041.17
0.650.851.08
340474580
404554660
261-92-3320261-92-3324
2024
8080
1.321.46
1.371.67
722880
8281023
� area for calculation of cabletray fill in accordance with NEC Section 392.22
Cut lengths of 1000 feet orlonger are subject to a tolerance of � 10%; lessthan 1000 feet � 15%.
� Available from ourCustomer Service Centers.
E/13110547
ULR
Okobus
Single Pair or Multiple Shielded Pairs - Overall Shield 300 V 75°C Rating
a) Characteristic Impedance, zo, at fr(31.25kHz), minimum ........................100 ohms
b) Maximum attenuation at1.25 fr (39 kHz)..................................3.0 dB/km
c) Maximum capacitive unbalanceto shield...............................................2 nF/km
d) Maximum DC resistance(per conductor) ................................24 ohms/km
e) Maximum propagation delaychange 0.25 fr to 1.25 fr.....................1.7 �s/km
f) conductor cross-sectional area nominal(wire size) ..................................0.8 mm2 (#18 AWG)
g) Minimum shield coverage.....................100%
�
THE OKONITE COMPANYRamsey, New Jersey 07446
#18 AWG tinned copper,Class M, stranded per ASTM B-174.
Okolene® (Polypropylene)per UL 13 and 2250, 32 mils nominalthickness, 75°C temperature rating.
Pigmented or-ange and blue in pairs, orange conductornumerically printed for group identification.
Aluminum/Polyester tapeoverlapped to provide 100% coverage,and a Class M tinned copper drain wire,two sizes smaller than the conductor. Allmulti-pair shields are isolated from eachother.
Pairs assembledwith a left-hand lay. Cable fillers includedwhere required to provide a round cable.
Alumi-num/Polyester tape overlapped to provide100% coverage, and a class M strandtinned copper drain wire, same size asconductor.
Orange, flame-retardant,Okoseal per UL 13 and 2250. A rip cord islaid longitudinally under the jacket to facili-tate removal.
A close-fitting, impervious,continuously welded and corrugated, alu-minum sheath provides completeprotection against moisture, liquids, andgases, has excellent mechanical strength,and provides equipment groundingthrough the sheath.
: Orange, flame-retardant,Okoseal per UL 13 and 2250.
UL Listed asPLTC-Power Limited Tray Cable and asITC-HL - Instrument Tray Cable/Hazard-ous Locations for use in accordance withArticle 727 and Article 725 of the NationalElectrical Code.
Cables comply with ISA-S-50-02, UL 2250and UL 13 for Fieldbus circuits and CL2and CL3.
C-L-X OKOBUS® cables are designed foruse in rugged plant and off-shore marine
environments utilizing networked discreteor process automation and control.ITC-HL (Instrument Tray Cable - Hazard-ous Locations) eliminates the need forconduit when installed in accordancewith NEC Article 501.10(A)(1)(d)"ITC-HL" installations. Fully complieswith ANS/ISA 50.02 Part 2 FieldbusCable.
The isolated individual shields overeach pair, in SP-OS cables, whenproperly grounded, prevent crosstalkor capacitive coupling between adja-cent pairs which occurs with acsignals, particularly the pulse type.
The overall shield eliminates most of thestatic interference from the electrical fieldradiated by power cables and other elec-trical equipment.
The C-L-X sheath provides additionalelectrical shielding and physical protec-tion against mechanical damage as wellas complete protection against moistureor gases entering the cable.
• Passes the UL 13 and IEEE 383 verticaltray flame tests.
• Passes IEEE 1202 vertical tray flametest.
• Sunlight & oil resistant.
• UL listed for direct burial.
• Complete pre-packaged, factory-testedwiring system-color coded.
• C-L-X enclosure permits installation incable tray containing lighting and power ca-bles without a barrier separator.
• Individual pairs are completely isolated.
• Impervious, continuous sheath excludesmoisture, gases and liquids.
• C-L-X sheath exceeds equipmentgrounding conductor requirements of NECArticle 250.
• Lower installed system cost than conduitor EMT systems.
Tinned Copper StrandedConductorPolypropylene InsulationTinned Stranded Copper GroupDrain WireAluminum/Polyester TapeTwisted, Shielded PairsAluminum/Polyester TapeTinned Stranded Copper DrainWireRip CordInner Orange Okoseal JacketImpervious, Continuous, CorrugatedAluminum C-L-X SheathOuter Orange Okoseal Jacket
Okobus C-L-X
Single Pair or Multiple Shielded Pairs - Overall Shield300 Volts 75°C Rating
ULR
� 564-92-3301561-92-3302
12
4550
0.340.55
0.530.80
4050
0.620.91
0.300.65
155311
194391
561-92-3304561-92-3306
46
6060
0.710.81
0.931.06
5050
1.041.17
0.851.08
400493
480573
561-92-3308561-92-3312561-92-3316
81216
707070
0.911.041.17
1.151.341.47
505050
1.261.451.58
1.251.651.96
587759902
693902
1045
561-92-3320561-92-3324
2024
8080
1.331.46
1.641.78
5050
1.751.89
2.412.81
10721308
12361495
� area for calculation of cable tray fillin accordance with NEC Section 392.22.
C-L-X available on special order.Cut lengths of 1000 feet or longer
are subject to a tolerance of � 10%; less than 1000feet � 15%.� Available from our Cus-tomer Service Centers.
E/11110548
ULR
Okobus — C-L-X
Single Pair or Multiple Shielded Pairs - Overall Shield 300 V 75°C Rating
�
a) Characteristic Impedance, Zo, at fr(31.25kHz), minimum ............................100 ohms
b) Maximum attenuation at1.25 fr (39 kHz)......................................3.0 dB/km
c) Maximum capacitive unbalanceto shield...................................................2 nF/km
d) Maximum DC resistance(per conductor) ....................................24 ohms/km
e) Maximum propagation delaychange 0.25 fr to 1.25 fr.........................1.7 �s/km
f) conductor cross-sectional area nominal(wire size) ......................................0.8 mm2 (#18 AWG)
g) Minimum shield coverage .........................100%
THE OKONITE COMPANYRamsey, New Jersey 07446
SpecificationsConductors: Bare copper, Class B,stranded per ASTM B-8.
Insulation: X-Olene (XLPE), per UL 13,2250 & 1569, 30 mils nominal thickness,90°C temperature rating. MeetsMIL-DTL-1377H, section 4.8.4.1.2 ColdBend at -66°C and ASTM D746-04brittlepoint at -76°C.
Conductor Identification: Pigmented blackand white in pairs, black, red and white in tri-ads; white conductor numerically printed forgroup identification.
Pair Shield: Aluminum/Polyester tapeoverlapped to provide 100% coverage, anda Class B tinned copper drain wire, twosizes smaller than the conductor. Allmulti-pair shields are isolated from eachother.
Multiple Pair Assembly: Pairs assembledwith a left-hand lay. Cable fillers includedwhere required to provide a round cable.
Multiple Pair Cable Shield: Alumi-num/Polyester tape overlapped to provide100% coverage, and a class B strand tinnedcopper drain wire, same size as conductor.
Inner Jacket: Black, flame-retardant, lowtemperature Okoseal® (PVC) per UL 13 andUL Standard 2250. The inner jacket meetsthe thickness requirements of UL standard1277. A rip cord is laid longitudinally underthe jacket to facilitate removal.
C-L-X Sheath: A close-fitting, impervious,continuously welded and corrugated, alumi-num sheath provides complete protectionagainst moisture, liquids, and gases, has ex-cellent mechanical strength, and providesequipment grounding through the sheath.
Outer Jacket: Black, flame-retardant, lowtemperature Okoseal per UL 13 and ULStandard 2250.
Applications
ITC-HL and MC-HL cables eliminate theneed for conduit when installed in accor-dance with NEC Article 501.10(A)(1)(d)"ITC-HL" or 501.10(A)(1)(C) "MC-HL" instal-lations. UL listed as PLTC-Power LimitedTray Cable and as ITC-HL - Instrument TrayCable/Hazardous Locations for use in accor-dance with Article 725 (Class 1, 2 & 3) andArticle 727 of the National Electrical Code.
UL listed as MC-HL for use in Class I, II,and III, Divisions 1 and 2 hazardous loca-tion in accordance with NEC Articles 501,502, 503, 504 & 505; in Zone 2, Class II Div2, Class III Div 1 and Class III Div 2 perCEC.
The isolated individual shields over eachpair, in SP-OS cables, when properlygrounded, prevent crosstalk or capacitivecoupling between adjacent pairs while theoverall shield eliminates most of the staticinterference from the electrical field radi-ated by power cables and other electricalequipment.
Product FeaturesComplete pre-packaged, factory-testedwiring system-color coded.
C-L-X enclosure permits installation in ca-ble tray containing lighting and powercables without a barrier separator.
Lower installed system cost than conduit orEMT systems.
Applicable Standards• UL listed for cable tray use, direct burial, inducts, and sunlight resistant.
• Vertical Tray Flame Tests;IEEE 383-1974 & FT4/IEEE 1202.
• UL listed at -50°C. Also, meets the CSA22.2 No.3 Cold Impact Test at -45°C.
• API Standards 14F and 14FZ.
• ASTM B-8.
• OSHA Acceptable
• UL 2225 Type MC-HL & UL 1569
• NEC Articles 501, 502, 503, 504 and 505for Classes I, II, and III, Divisions 1 and 2Hazardous Locations.
• UL listed as PLTC-Power Limited Tray Ca-ble and as ITC-HL - Instrument TrayCable/Hazardous Locations for use in accor-dance with Article 725 (Class 1, 2 & 3) andArticle 727 of the National Electrical Code.
• NPLF per NEC Code Article 760.
• CSA C22.2 No. 230 Type TC
• CSA C22.2 No. 239 type ACIC
• cUL listed as Type ACIC-TC complies withCEC Zone 2, Class II Div 2, Class III Div 1,Class III Div 2 Hazardous Locations.
Product DataSection 5: Sheet 49
C-L-X X-Olene® P-OS, SP-OSUL Type MC-HL, PLTC, ITC-HL and cUL ACIC-TC Instrumentation CableSingle Pair/Triads or Multiple Shielded Pairs/Triads - Overall Shield600 Volts 90°C Rating: UL MC-HL and cUL ACIC-TC300 Volts 90°C Rating: UL PLTC & ITC-HLFor Cable Tray Use Sunlight Resistant For Direct Burial -50°C
(UL
)TY
PE
PL
TC
or
ITC
-HL
90°C
(UL
)TY
PE
PL
TC
or
ITC
-HL
90°C
A Copper Stranded ConductorB X-Olene InsulationC Tinned Stranded Copper Group
Drain WireD Aluminum/Polyester TapeE Twisted, Shielded PairsF Aluminum/Polyester TapeG Tinned Stranded Copper Drain
WireH Rip CordJ Inner Okoseal JacketK Impervious, Continuous, Corrugated
Aluminum C-L-X SheathL Outer Okoseal Jacket
ULR c ULR
567-70-3302567-70-3304
24
4560
0.500.67
0.710.89
5050
0.821.00
0.530.79
253365
333445
567-70-3308567-70-3312
812
6080
0.831.00
1.061.29
5050
1.171.40
1.081.54
503693
583799
567-70-3324567-70-3336
2436
8080
1.341.55
1.641.92
6060
1.782.05
2.483.29
11251545
12901835
567-71-3302567-71-3304567-71-3308
248
606080
0.620.730.98
0.840.971.24
505050
0.951.081.35
0.710.921.43
326428658
406508764
567-71-3312567-71-3324
1224
8080
1.151.58
1.471.96
5060
1.582.09
1.963.42
8601505
10031760
� area for calculation of cable tray fill inaccordance with NEC Section 392.9.
- Optional jacket types available - consult localsales office.
C-L-X available on special order.To order without the outer Okoseal jacket (not "HL" listed),change the sixth digit of the catalog number from 3 to 1, forexample to order 1 pr. 16 AWG with a bare aluminum C-L-X,the catalog number would be 567-75-1401.
Cut lengths of 1000 feet or longer aresubject to a tolerance of � 10%; less than 1000 feet � 15%.
E/14120549
C-L-X X-Olene P-OS, SP-OS
Single Pair/Triads or Multiple Shielded Pairs/Triads - Overall Shield600 Volts 90°C Rating: UL MC-HL and cUL ACIC-TC300 Volts 90°C Rating: UL PLTC & ITC-HL
�
Conductor Resistance, nominal - ohms/1000 ft......@20°C ..........@25°C16 AWG ................................................................4.34 .................4.4318 AWG ................................................................6.93 .................7.07
Insulation Test Voltage (spark test) ....................................7500 Volts ac
Dielectric Test Voltage .......................................................3000 Volts ac
Insulation Resistance Constant @60°F minimum ...10,000 ohms-1000 ft.
Loop Resistance, nominal (2 cdr.) - ohms/1000 ft .@20°C ..........@25°C16 AWG .................................................................8.68 .................8.8618 AWG .................................................................13.9 .................14.2
Mutual Capacitance (PF/ft.)*#16 ....................................................................................................23#18 ....................................................................................................21
*Typical Value
THE OKONITE COMPANYRamsey, New Jersey 07446
567-75-3401567-70-3402567-70-3404
124
456060
0.350.580.70
0.580.800.93
505050
0.690.911.04
0.370.650.85
180325424
219405504
567-70-3408567-70-3412567-70-3424
81224
808080
0.921.101.44
1.191.371.78
505060
1.301.481.91
1.331.732.87
650842
1450
752985
1640
567-70-3436567-76-3401567-71-3402
3612
1104560
1.820.370.64
2.190.580.89
605050
2.320.691.00
4.230.370.79
2145195376
2480234456
567-71-3404567-71-3408567-71-3412
48
12
608080
0.751.061.26
1.021.341.56
505060
1.131.451.69
1.001.642.24
500800
1090
580945
1235
ULRc ULR
ApplicationsOkonite X-Ray cables are suitable for use onX-Ray apparatus for medical, industrial, re-search and control applications. They givetrouble-free performance where pulse typehigh voltages are required. Although primar-ily used with medical diagnostic imagingequipment, Okonite X-Ray cables are alsoused with equipment in industrial applica-tions as well as in research projects wherehigh voltages, low power are required.Okonite LOW NOISE X-Ray cables havespecifically been designed for use wheresensitive measurements are required. TheseLOW NOISE cables are manufactured andassurance tested to meet less than 10 pico-coulumb discharge thereby reducing noise toa minimum.Okonite LOW NOISE X-Ray cables are of-fered at 65kV, 75kV, 100kV, 230kV and250kV dc ratings.Typically, Okonite X-Ray cables are used tosupply the anode and cathode voltages tothe X-Ray tube. Since one terminal operatesat a negative potential and the other at apositive potential, the voltage across the X-Ray tube is twice (2X) the rated voltage ofthe cable.The two usual constructions are (1) threeconductor (3/C) used on typical cathode ca-ble installations, and (2) four conductor (4/C)utilized on installations with a grid controlledlead. Upon request, designs and construc-tions can be developed for specialapplications.
Product Features
• Low Noise - < 10 pC @ 200 Vac/mil of in-sulation to 42 kV max.• Performance tested for long trouble-freeservice.• Small diameter.• Flexible construction.• Excellent flexing endurance.• Mechanically rugged.• Easy to strip and terminate.• Resistant to most oils and chemicals.• Complies with NEMA Standard XR-7where applicable.
InstallationThe minimum bending radius for permanentinstallation or flexing in service is four timesthe cable diameter.
SpecificationsCable Core: Each Low Noise cable corecontains two insulated filament conduc-tor. In 65, 75, and 100kV cable filamentconductors are #15 AWG (19x)[1.65mm2] tinned copper insulated withheat sealed color coded polyester tape.In 230kV cables, the filament wires are#16 AWG (19x) [1.31mm2] tinned copper.The 250 kV cable filaments are #14 AWG(19x) [2.08mm2] tinned copper. Both the230 and 250kV filament wires are insu-lated with an extrusion of ETFE. Fourconductor cables include one #20 AWG(7x) [0.52mm2] copperweld conductor perASTM B-45 insulated with heat sealedpolyester and shielded with metalized redpolyester.The tinned copper uninsulated conductorin 3/C 65, 75, 100 and 230kV cables issegmented into two #18 AWG [0.83mm2]flex stranded wires. The 4/C uninsulatedconductor is segmented into three #18AWG wires. A single #12 AWG (19x) wireis used in the 250kV cable.Core Shield: An extruded layer of semi-conducting compound encapsulates thecomposite core assembly.High Voltage Insulation: Okonite’s pre-mium EPR (ethylene-propylene rubber)insulation. This ozone resistant high volt-age dielectric is extruded in tandem withthe semiconducting layers which insuresan intimate and contaminant free inter-face between the layers.Insulation Shield: A strippable extrudedlayer of semiconducting EPR compoundis applied directly over the insulation.Shield: A braid of tinned copper wires isapplied directly over the insulation shield.Minimum coverage indicated in table.Jacket: A flexible Okoseal (speciallycompounded PVC) jacket is extrudedover the shield to provide additional me-chanical strength and resistance to mostoils and chemicals.
Okonite X-Ray/Hi-Voltage CableLow Noise65kV, 75kV, 100kV, 230kV and 250kV dc RatingThree Conductor or Four Conductor
Product DataSection 6: Sheet 1
A Coated Stranded CopperConductors
B Polyester InsulationC Extruded Semiconducting LayerD Primary Insulation – OkoguardE Extruded Insulation ShieldF Coated Copper BraidG Jacket – Okoseal
A
B
C
E
F
G
D
65kV
3 Conductors2-#15 AWG insulated1-(2-#18 AWG)uninsulated
504-22-6436 80 yes Gray 0.465 11.81 0.605 15.36 219 33 243 36
75kV
3 Conductors2-#15 AWG insulated1-(2-#18 AWG)uninsulated
504-22-3437504-22-3495
8095
no Gray 0.510 12.95 0.650 16.50247258
3738
279297
4244
4 Conductors2-#15 AWG 1-#20AWG Copperweld,insulated1-(3-#18 AWG)uninsulated
504-22-4464 80 no Gray 0.570 14.48 0.715 18.20 296 44 335 50
75kVExtraSmall
Diameter
3 Conductors2-#15 AWG insulated1-(2-#18 AWG)uninsulated
504-22-3415 80 no Gray 0.490 12.45 0.620 15.75 228 34 267 40
100kV
3 Conductors2-#15 AWG insulated1-(2-#18 AWG)uninsulated
� 504-22-3436� 504-22-4437
80noyes
Gray 0.620 15.75 0.785 19.94 341 51 380 57
4 Conductors2-#15 AWG 1-#20AWG Copperweld,insulated 1-(3#18AWG) uninsulated
504-22-4436504-22-4437
80noyes
Gray 0.660 16.75 0.845 21.46 391 58 446 66
230kV
3 Conductors2-#16 AWG insulated1-(2-#18 AWG)uninsulated
� 504-22-741080 no Black
0.980� .020
24.89� .51
1.250� .025
31.75� .64
759 113 849 126
250kV
3 Conductors2-#14 AWG insulated1-(#12 AWG)uninsulated
504-22-9430 80 no Black1.280� .020
32.51� .51
1.505� .025
38.23� .64
1119 167 1250 186
Electrical Characteristics
Rated VoltageRectified dc kV (2)
Number ofConductors
Core to ShieldCapacitance ± 10%
4/C only: Copperweld grid lead capacitance = 70 pF/ft. (230 pF/m).
pF/ft. pF/m Conductor resistance @ 25°C:
6575 (ESD)7575
100100230250
33343433
5249.5475740493531
170162154187131159115101
#16 AWG (1.31 mm2) tinned copper = 4.18 ohms/1000 ft (1.37 ohms/100 m)#15 AWG (1.65 mm2) tinned copper = 3.51 ohms/1000 ft (1.15 ohms/100 m)#18 AWG (0.83 mm2) tinned copper = 7.16 ohms/1000 ft (2.34 ohms/100 m)
2 X #18 AWG (0.83 mm2) tinned copper = 3.58 ohms/1000 ft (1.17 ohms/100 m)3 X #18 AWG (0.83 mm2) tinned copper = 2.39 ohms/1000 ft (0.78 ohms/100 m)
#20 AWG (0.52 mm2) copperweld = 24.12 ohms/1000 ft (7.91 ohms/100 m)#14 AWG (2.08 mm2) tinned copper = 2.73 ohms/1000 ft (0.895 ohms/100 m)#12 AWG (3.31 mm2) tinned copper = 1.72 ohms/1000 ft (0.564 ohms/100 m)
(2) Voltage rating is between the conductor and the shielding braid.
C/06010601
Product DataSection 6: Sheet 1
� Authorized stock Item. Available from our Customer Service Centers.
(1) Cable is helically wrapped with a cellophane tape to maintain cleanliness during installation and includes a pull cord for ease of removal.
- Designs for special applications upon request.- Refer to Product Data Section 6 Sheet 1 for X-Ray Cable - Low Noise constructions.
THE OKONITE COMPANYRamsey, New Jersey 07446
Catalo
gNum
ber
Net. W
t.(k
g/100m
)
Jack
etColo
r
Insu
latio
nO.D
.
mm
±0.2
5
Insu
latio
nO.D
.
Inch
es±
0.010
Jack
etO.D
.
Inch
es±
0.015
Jack
etO.D
.
mm
±0.3
8
Tinned
CopperBra
id
Covera
ge (%)
Descr
iptio
n
Net. W
t.(lb
s/100
0 ft.)
Approx.
ShipW
eight
(kg./1
00m
)
Approx.
ShipW
eight
(lbs./
1000
’)
Okonite X-Ray/Hi-Voltage CableLow Noise65kV, 75kV, 100kV, 230kV and 250kV dc RatingThree Conductor or Four Conductor
Cellophan
e Wra
p(1
)
ApplicationsOkonite X-Ray cables are suitable for use onX-Ray apparatus for medical, industrial, re-search and control applications. They givetrouble-free performance where pulse typehigh voltages are required. Although primar-ily used with medical diagnostic imagingequipment, Okonite X-Ray cables are alsoused with equipment in industrial applica-tions as well as in research projects wherehigh voltages, low power are required.
Typically, Okonite X-Ray cables are used tosupply the anode and cathode voltages tothe X-Ray tube. Since one terminal operatesat a negative potential and the other at apositive potential, the voltage across the X-Ray tube is twice (2X) the rated voltage ofthe cable.
The two usual constructions are (1) threeconductor (3/C) used on typical cathode ca-ble installations, and (2) four conductor (4/C)utilized on installations with a grid controlledlead. Upon request, designs and construc-tions can be developed for specialapplications.
Product Features• Performance tested for long trouble-freeservice.• Small diameter.• Flexible construction.• Excellent flexing endurance.• Mechanically rugged.• Easy to strip and terminate.• Resistant to most oils and chemicals.• Complies with NEMA Standard XR-7where applicable.
InstallationThe minimum bending radius for permanentinstallation or flexing in service is four timesthe cable diameter.
SpecificationsCable Core: Each cable contains two #15AWG (19x) [1.65mm2] tinned copper filamentwires insulated with heat sealed color codedpolyester tape. Three conductor cores in-clude two uninsulated #18 AWG [0.83mm2]flex stranded tinned copper wires. Four con-ductor cables include one #20 AWG (7x)
[0.52mm2] copperweld conductor perASTM - 45 insulated with heat sealedpolyester and shielded with metalized redpolyester. The four conductor core in-cludes three uninsulated #18 AWG flexstranded tinned copper wires.
All conductors are twisted together into acomposite assembly.
Core Shield: An extruded layer of semi-conducting compound encapsulates thecomposite core assembly.
Insulation: Okonite’s premium high volt-age EPR (ethylene propylene rubber)insulation is extruded in tandem with thesemiconducting compound ensuring anintimate contaminant free bond betweenthe layers
Shield: A semiconducting tape is appliedover the insulation with a tinned copperwire braid. Minimum coverage indicatedin table.
Jacket: A light gray flexible Okoseal(specially compounded PVC) jacket isextruded over the shield to provide addi-tional mechanical strength and resistanceto most oils and chemicals.
Okonite X-Ray/Hi-Voltage Cable65kV, 75kV and 100kV dc RatingThree Conductor or Four Conductor
Product DataSection 6: Sheet 2
A Coated Stranded CopperConductors
B Polyester InsulationC Extruded Semiconducting LayerD Insulation – OkoguardE Semiconducting TapeF Coated Copper BraidG Jacket – Okoseal
A
B
C
E
F
G
D
65kV
3 Conductors2-#15 AWG insulated1-(2-#18 AWG)uninsulated
504-22-6040504-22-6041
80yesno
Gray 0.465 11.81 0.605 15.40 219 33 252 38
75kV
3 Conductors2-#15 AWG insulated1-(2-#18 AWG)uninsulated
� 504-22-3165504-22-3164504-22-3836
808095
yesnoyes
Gray 0.510 12.95 0.650 16.50236236248
353537
273273278
414142
4 Conductors2-#15 AWG insulated1-#20 AWGCopperweld, insulated1-(3-#18 AWG)uninsulated
504-22-2164 80 no Gray 0.570 14.48 0.715 18.20 289 43 333 50
75kVExtraSmall
Diameter
3 Conductors2-#15 AWG insulated1-(2-#18 AWG)uninsulated
� 504-22-3015 80 no Gray 0.490 12.45 0.600 15.25 224 34 248 37
100kV
3 Conductors2-#15 AWG insulated1-(2-#18 AWG) uninsu-lated
504-22-1033504-22-1035
80noyes
Gray 0.620 15.75 0.785 19.90 332 49 371 55
4 Conductors2-#15 AWG insulated1-(#20 AWG) Copper-weld, insulated1-(3#18 AWG)uninsulated
504-22-2041 80 no Gray 0.660 16.75 0.845 21.50 380 57 441 66
Electrical Characteristics
Rated VoltageRectified dc kV (2)
Number ofConductors
Core to ShieldCapacitance ± 10%
4/C only: Copperweld grid lead capacitance = 70 pF/ft. (230 pF/m).
pF/ft. pF/m Conductor resistance @ 25°C:
6575 (ESD)7575
100100160250
33343433
5249.5475740493531
170162154187131159115101
#16 AWG (1.31 mm2) tinned copper = 4.18 ohms/1000 ft (1.37 ohms/100 m)#15 AWG (1.65 mm2) tinned copper = 3.51 ohms/1000 ft (1.15 ohms/100 m)#18 AWG (0.83 mm2) tinned copper = 7.16 ohms/1000 ft (2.34 ohms/100 m)
2 X #18 AWG (0.83 mm2) tinned copper = 3.58 ohms/1000 ft (1.17 ohms/100 m)3 X #18 AWG (0.83 mm2) tinned copper = 2.39 ohms/1000 ft (0.78 ohms/100 m)
#20 AWG (0.52 mm2) copperweld = 24.12 ohms/1000 ft (7.91 ohms/100 m)
(2) Voltage rating is between the conductor and the shielding braid.
B/03040602
Product DataSection 6: Sheet 2
� Authorized stock Item. Available from our Customer Service Centers.
(1) Cable is helically wrapped with a cellophane tape to maintain cleanliness during installation and includes a pull cord for ease of removal.
- Designs for special applications upon request.- Refer to Product Data Section 6 Sheet 1 for X-Ray Cable - Low Noise constructions.
THE OKONITE COMPANYRamsey, New Jersey 07446
Catalo
gNum
ber
Net. W
t.(k
g/100m
)
Jack
etColo
r
Insu
latio
nO.D
.
mm
±0.2
5
Insu
latio
nO.D
.
Inch
es±
0.010
Jack
etO.D
.
Inch
es±
0.015
Jack
etO.D
.
mm
±0.3
8
#34 AW
GT.C
. Bra
id
Covera
ge (%)
Descr
iptio
n
Net. W
t.(lb
s/100
0 ft.)
Approx.
ShipW
eight
(kg./1
00m
)
Approx.
ShipW
eight
(lbs./
1000
’)
Okonite X-Ray/Hi-Voltage Cable65kV, 75kV, 100kV dc RatingThree Conductor or Four Conductor
Cellophan
e Wra
p(1
)
Insulation/JacketOkoguard is Okonite’s registered tradename for its exclusive ethylene-propyl-ene base, thermosetting compound,whose optimum balance of electricaland physical properties is unequaled inother solid dielectrics.
This durable Okoguard insulation servesas a jacket as well. It is permanentlyembossed with a legend and has anatural, highly visible, red color.
ApplicationsOkoguard Portable Jumper cables aredesigned as flexible power leads for usewith tap-off or jumper clamps which per-mit temporary connections or “by-pass”of energized aerial lines operating atvoltages up to and including 15000V(phase to phase).
SpecificationsExtra-flexible rope
tin coated copper per ASTM B-33, flexi-ble rope stranded.
: A taped conductivescreen, whose purpose is to improveservice life, dielectric strength and elimi-nate internal corona, meets andexceeds ICEA Standard S-96-639.
Okoguard meets and ex-ceeds ICEA Standard S-93-639.
Product FeaturesExtra-flexible conductors for ease
of handling under adverse condi-tions.
Conductor screen for improvedvoltage stress control.
• Heat, moisture and ozone resistant90°C Okoguard Insulation/Jacket.
• Okoguard is red for visual attentionand it has good color stability evenwhen exposed to strong sunlight.
• Excellent low temperatureproperties.
Okoguard® Aerial Jumper Cable
Coated, Stranded CopperConductorStrand ScreenInsulation/Jacket-Okoguard
Okoguard Aerial Jumper Cable
� 303-21-1934� 303-21-1938� 303-21-1940� 303-21-1944
21/02/04/0
259259259437
0.3190.4080.4500.592
0.7800.8630.9101.052
19.822.023.327.2
425583687997
480638752
1092
192258298400
� Available from our Customer Service Centers
is 150 ft.—1000' N.R. Reel. Standard package will be
furnished where orders do not specify otherwise.
C/12040604THE OKONITE COMPANY
Ramsey, New Jersey 07446
Ampacity based on 90°C conductor temperature, 40°C ambient temperature.For ampacity correction factors covering various ambient temperatures:
AmbientTemperature
DegreesCorrection
Factor
C F
1020304050
506886
104122
1.261.181.101.000.90
Okoguard is Okonite’s registered trade namefor its exclusive medium voltage grade ethyl-ene-propylene rubber (EPR) based,thermosetting compound, whose optimumbalance of electrical and physical propertiesis unequaled in other solid dielectrics.Okoguard insulation, with the distinctive redcolor and a totally integrated EPR system,provides the optimum balance for long, prob-lem free service.
The Okolon TS-CPE jacket on this cable is avulcanized chlorinated polyethylene basedcompound which is mechanically rugged,flame, and oil resistant.
Okoguard-Okolon TS-CPE cables are heavyduty nonshielded cables designed for use atup to 5kV in wet or dry airport lighting appli-cations.Okoguard-Okolon TS-CPE nonshielded air-port lighting cables are recommended foruse in series lighting circuits for runways andcontrol systems. Cables can be installed inmetallic or non-metallic conduit, directly bur-ied or aerial application.
Meets or exceeds the requirements of FAAAdvisory Circular AC 150/5345-7F.
Annealed uncoated coppercompact Class B stranded per ASTM B-496.
Extruded semiconduct-ing EPR strand screen. Meets or exceedselectrical and physical requirements ofICEA S-96-659/NEMA WC71.
Meets or exceeds electricaland physical requirements of ICEAS-96-659/NEMA WC71. Insulation thick-ness per Table 4-3 for wet or dryapplications.
Meets or exceeds electrical andphysical requirements of ICEAS-96-659/NEMA WC71 for chlorinatedpolyethylene jackets.
• Resistant to runway and wing de-icers• 90°C Continuous Rating,130°C Emergency Overload Rating,250°C Short Circuit Rating• Exceptional resistance to surfacetracking• Superior Flexibility• Constructed for “wet” locationapplications• Excellent corona resistance• Stress cones not required• Resistant to most oils, acids, andalkalies
*Applications governed by the NationalElectrical Code limit non-shielded cableto 2.4kV
Okoguard®-Okolon® TS-CPE5kV Airport Lighting Cable*
One Okopact (Compact Stranded) Copper Conductor/90°C Rating Wet or Dry
Uncoated, Okopact (CompactStranded) Copper ConductorStrand Screen-ExtrudedSemiconducting EPRInsulation-Okoguard EPRJacket-Okolon TS-CPE
� 114-24-2213� 114-24-2217
8 8.46 13.3
125 3.18125 3.18
80 2.0380 2.03
0.60 15.10.63 16.0
215260
250295
� Available from our Customer Service Centers.
are available.
E/14080606 THE OKONITE COMPANYRamsey, New Jersey 07446
A
B
C
D
Okonite EPR insulation is a heat, mois-ture and chemical resistant,mechanically rugged compound. The in-sulation thickness for size #14 AWGthrough #9 AWG is 5/64" and for #6AWG through #2 AWG is 6/64". Oneconductor in each layer is identified as"Tracer". In addition, each conductor isnumber coded for ease of identification.
Individual conductors are assembledwith suitable fillers, where necessary,and a cable cushioning tape. A 7 mil flatcopper alloy tape is then helically ap-plied, giving outstanding mechanicalprotection. The black Okolene® (poly-ethylene) jacket is then applied overall.
Okonite Armored Underground SignalCables are designed for use in all vitalrailroad signal circuits where security ofservice and long life are required in allvital circuit and safety related applica-tions. These cables are recommendedfor use where crush resistance, termiteand rodent protection are considera-tions and in all wet and dry locations.
Solid uncoated copperper ASTM B-3, stranded uncoated com-pact round copper per ASTM B-496.
Meets or exceeds electri-cal and physical requirements ofICEA S-95-658 (NEMA WC70) andAREMA Manual Part 10.3.19, thick-ness per table 10317-4.
Copper alloy C19400per ASTM B-465.
Meets or exceeds electricaland physical requirements of ICEAS-95-658, Part 4.1.5.
• Mechanically rugged.• Resistant to aging.• Easy to install and splice.• Resistant to environmental haz-ards.• Superior moisture resistance.• Outstanding termite and rodent pro-tection.• Excellent electrical properties...high dielectric strength, low SIC andpower factor and high insulation re-sistance.• The Pull Cord feature affords easyand quick accessibility to conductorsfor splicing and terminating.• Sequential footage markings onsurface of outer jacket.
Okonite ArmoredUnderground Signal Cables
Multiple Copper Conductors/90°C Rating
Solid or stranded, UncoatedCopper ConductorsInsulation—Okonite #14 AWG-#9AWG 5/64”, #6 - #2 AWG 6/64” withprinted number code and tracerCushion Tape LayerFlat Copper Alloy Armor TapePull CordJacket—Okolene with sequentialfootage markings
#14 AWG through #9 AWG 5/64”, #6 AWG 6/64”
206-11-8974� 206-11-8255� 206-11-6283
7/C15/C19/C
2 x 9 (1X)3 x 6 (1X)6 x 6 (1X)
5 x 14 (1X)12 x 14 (1X)13 x 14 (1X)
566
0.991.481.69
52317111674
57413191877
� - Available from Customer Service Centers.
are also available with stranded conductors.Consult your Okonite Representative.
B
A
E
D
F
Okonite ArmoredUnderground Signal Cables
� 206-11-6882206-11-6883206-11-6884
141414
Sol.Sol.Sol.
234
444
.65
.68
.74
208253300
241286338
� 206-11-6885� 206-11-6887
206-11-6889
141414
Sol.Sol.Sol.
579
455
.81
.911.05
349451579
408510671
206-11-6890� 206-11-6892
206-11-6895
141414
Sol.Sol.Sol.
101215
556
1.121.171.33
698700871
790792994
206-11-6896� 206-11-6899
206-11-6901
141414
Sol.Sol.Sol.
161921
666
1.331.401.47
90610281127
102911511250
� 206-11-6907� 206-11-6910
206-11-6692
141412
Sol.Sol.Sol.
2737
2
674
1.671.89
.68
13881834
240
16382076
273
206-11-6693206-11-6694206-11-6695
121212
Sol.Sol.Sol.
345
444
.72
.78
.85
292354412
330392471
206-11-6697206-11-6699206-11-6700
121212
Sol.Sol.Sol.
79
10
555
.961.111.19
535689774
594781866
206-11-6702206-11-6812206-11-6813
121010
Sol.Sol.Sol.
1223
544
1.24.72.76
847279346
952317384
206-11-6814206-11-6815206-11-6817
101010
Sol.Sol.Sol.
457
455
.83
.941.02
424518654
483577746
206-11-6819206-11-6820206-11-6822
101010
Sol.Sol.Sol.
91012
566
1.181.301.36
842973
1076
93410781199
206-11-6922� 206-11-6923
206-11-6924
999
Sol.Sol.Sol.
234
445
.75
.79
.90
317384495
350443554
� 206-11-6925� 206-11-6927
206-11-6928206-11-6929
9999
Sol.Sol.Sol.Sol.
5789
5555
.971.061.141.23
581737843952
640829935
1057
� 206-11-6930206-11-6931
� 206-11-6242
996
Sol.Sol.Sol.
1012
2
665
1.351.42
.94
10981215
505
12211338
564
� 206-11-6243206-11-6244
� 206-11-6245
666
Sol.Sol.Sol.
345
555
1.001.101.20
632789952
724881
1044
� 206-11-6247206-11-6248206-11-6249
666
Sol.Sol.Sol.
789
666
1.341.451.56
124514291642
136815521820
� 206-11-6070� 206-11-6042� 206-11-6045� 206-11-6130
6442
7777
3253
5566
1.011.021.341.28
698619
12661256
753674
13561346
is 1000 ft. Standard Package—1000' N.R. Reel.
� Available from Customer Service Centers.
(1) This construction is also available with stranded conductors. Consult yourOkonite Representative.E/14040701
THE OKONITE COMPANYRamsey, New Jersey 07446
Okonite EPR is Okonite's tradename for its heat resistant, mechani-cally rugged ethylene-propylenebased insulating compound. The in-sulation thickness for wire sizes #9AWG is 5/64" and for #6 AWG is6/64".
The Okolene (PE) jacket suppliedwith this cable provides excellent re-sistance to mechanical abuse,weathering and most acids, oils andalkalies. Color Coded; 1-Black,1-Red.
Okonite-Okolene 600V Duplex TrackWire is recommended for use intrack circuits, signal operations, carretarder and switch machine appli-cations. Can be installed in eitherwet or dry locations, in conduit traysor trough or buried direct.
Solid uncoated cop-per per ASTM B-3.
Per ICEA S-95-658,and AREMA Signal Manual Part10.3.19.
Meets or exceeds thephysical and electrical require-ments of ICEA S-95-658, andAREMA Signal Manual Part10.3.21
• Exceptional heat resistance.• 90°C Continuous Rating130°C Emergency Overload Rat-ing.250°C Short Circuit Rating.• Mechanically rugged.• Flexible, easy to handle andsplice.• Resistant to most oils, acids, al-kalies and effects of weather.• Stable electrical and physicalproperties.• Excellent moisture resistance.
Okonite®-Okolene® Duplex Track Wire
One Copper Conductor/90°C Rating
Solid Uncoated Copper ConductorsInsulation - Okonite-Sizes #9 AWGand #8 AWG-5/64", #6 AWG-6/64"Jacket-Okolene, Color Coded;1-Black, 1-Red
150-12-3931� 150-12-3933
96
SolidSolid
44
0.83"1.00"
199329
243404
� Authorized Stock Item: Available from our Customer Service Center-1000' Non-Returnable Reel
THE OKONITE COMPANYRamsey, New Jersey 07446E/11100706
B
A
Okonite EPR is Okonite's trade name for itsheat resistant, mechanically ruggedethylene-propylene based insulating com-pound. The insulation thickness for wiresizes are listed below.
The Blue Okoseal® (PVC) jacket suppliedwith this cable provides excellent resistanceto mechanical abuse, flame, weathering, andmost acids, oils, and alkalies.
Okonite Tower and Case Wire is recom-mended for use as relay and associatedsignal apparatus wiring and for connectorwire use where a flexible, small diameterwire is required.
Uncoated stranded copperstranded per ASTM B-8.
Per ICEA S-95-658. Meets orexceeds all requirements for EPR insulation.
Per ICEA S-95-658. Meets or ex-ceeds all requirements.Okonite Tower and Case Wire meets or ex-ceeds the requirements of AREMA ManualPart 10.3.15.
• Exceptional heat resistance.• 90°C Continuous Rating130°C Emergency Overload Rating.250°C Short Circuit Rating.• Mechanically rugged.• Flexible, easy to handle and splice.• Flame resistant—meets U.L. horizontalflame test.• Resistant to most oils acids, alkaliesand effects of weather.• Stable electrical and physical proper-ties.
Okonite® TC BlueTower and Case Wire
One Copper Conductor/90°C Rating
Uncoated, Stranded CopperConductorInsulation—OkoniteJacket—Blue Okoseal
� 152-11-3002� 152-11-3024
152-11-3026
161412
191919
303045
202020
.17
.20
.23
202642
242846
� 152-11-3038152-11-3108152-11-3010
1010
9
193719
304545
202025
.23
.26
.29
565871
606275
� - Available from our Customer Service Centers.The construction described has a Blue Jacket. Consult your local Okonite Representa-
tive for details about alternate colors.- #16 AWG and #14 AWG, 10000 spool; #12 AWG, #10 AWG,
and #9 AWG, 500' spool.
THE OKONITE COMPANYRamsey, New Jersey 07446D/11100710
B
A
Okonite EPR is Okonite’s trade namefor its heat resistant, mechanically rug-ged ethylene-propylene based insulatingcompound. The insulation thickness forwire size #16 AWG and #14 AWG is2/64" and for #12 AWG and #10 AWG itis 3/64".
The Okolon (TS-CP) jacket suppliedwith this cable provides excellent resis-tance to mechanical abuse, flame,weathering and most acids, oils and al-kalies.
Okonite Okolon (TS-CP) 600V CaseWire is recommended for use as relayand associated signal apparatus wiringand for connector wire use where a flex-ible, small diameter wire is required.
Uncoated stranded copperper ASTM B-8.
Per ICEA S-95-658.Per ICEA S-95-658, Part 4.1.13
and 4.1.3.
• Exceptional heat resistance.• 90°C Continuous Rating130°C Emergency Overload Rating.250°C Short Circuit Rating.• Mechanically rugged.• Flexible, easy to handle and splice.• Flame resistant — meets U.L. hori-zontal flame test.• Resistant to most oils, acids, al-kalies and effects of weather.• Stable electrical and physical prop-erties.
Okonite® Okolon® - (TS-CPE) Case Wire
One Copper Conductor/90°C Rating
Uncoated, Stranded CopperConductorInsulation—Okonite—#16 AWG and#14 AWG - 2/64"; #12 AWG thru #6AWG - 3/64"Jacket - Okolon TS-CPE
151-12-1051�151-12-1081
151-12-1101
161412
191919
111
.16
.18
.23
202642
243046
151-12-1140151-12-1171
�151-12-1201
1096
191919
111
.25
.26
.31
5867
112
6275
122� Authorized Stock Item - Available from Customer Service Centers.
— #16 AWG and #14 AWG, 1000’ spool; #12 AWG thru #6 AWG, 500’ spool.
THE OKONITE COMPANYRamsey, New Jersey 07446
G/11100711
B
A
TH
EO
KO
NIT
EC
O.O
KO
LON
TS
-CP
EC
AS
EW
IRE
InsulationOkonite EPR is Okonite's tradename for its heat resistant, mechani-cally rugged ethylene-propylenebased insulating compound. The in-sulation thickness for wire sizes #16AWG and #14 AWG is 2/64" and for#12 AWG through #9 AWG it is3/64".
FinishThe nylon braid and lacquer finishsupplied with this cable provides ex-cellent resistance to mechanicalabuse, weathering and most oils, ac-ids and alkalies.
ApplicationsOkonite-Nylon Braid 600V CaseWire is recommended for use as re-lay and associated signal apparatuswiring, and for connector wire usewhere a flexible, small diameter wireis required.
SpecificationsConductor: Uncoated, strandedcopper conductor per ASTM B-8.Insulation: Per ICEA S-95-658.Finish: Black nylon braid (100%coverage) with clean lacquer fin-ish.
Product Features• Mechanically rugged.• 90°C Continuous Rating130°C Emergency Overload Rat-ing.250°C Short Circuit Rating.• Mechanically rugged.• Flexible, easy to handle andsplice.• Resists most oils, acids, alkaliesand effects of weather.• Stable electrical and physicalproperties.
Okonite®-Nylon Braid Case Wire600VOne Copper Conductor/90°C Rating
Product DataSection 7: Sheet 12
A Uncoated, Stranded CopperConductor
B Insulation—Okonite #16 and #14AWG 2/64"; #12 AWG through #9AWG 3/64"
C Finish—Nylon Braid with LacquerOverall
Nominal Finish Thickness: 5 mils
CatalogNumber Size AWG No. of
Strands
InsulationThickness
64 th's
Approx.O.D. (In.)
Approx.Net Wt.Lbs./M'
Approx.Ship Wt.Lbs./M'
�151-12-9051151-12-9081151-12-9111
161412
191919
223
.14
.15
.20
162238
202642
151-12-9145�151-12-9161
151-12-9181
10109
193719
333
.22
.23
.24
505162
545566
� Authorized Stock Item — Available from our Customer Service CentersStandard Package — #16 AWG and #14 AWG, 1000' spool;#12 AWG, #10 AWG, and #9 AWG, 500' spool.
THE OKONITE COMPANYRamsey, New Jersey 07446
E/15070712
B
A
C
Okonite EPR® is Okonite’s trade namefor its heat resistant, mechanically rug-ged ethylene-propylene based insulatingcompound. The insulation thickness forDEL numbers 002 and 004 is 2/64”, for008 through 016 is 3/64”, 018 through026 is 4/64”, 030 through 040 is 5/64”,044 and 048 is 6/64”, 050 through 056 is7/64” and for 058 it is 8/64”.
The Okolon TS-CPE jacket suppliedwith this cable provides excellent resis-tance to mechanical abuse, flame,weathering, most oils, acids and alka-lies.
Okonite Type DEL, Diesel-Electric Loco-motive Traction and Car Wires isdesigned for use in locomotives and carequipment circuits where reliability is forprime consideration. DEL can also beused in other low voltage applicationswhere flexibility is important. It is suit-able for use in wet or dry locations, inconduits, ducts, cable troughs or trays.
Coated copper strandedper AREMA Recommended Practice,Section M, RP-588, as applicable andICEA S-95-658.
Per AREMA RecommendedPractice, Section M, RP-588, as applica-ble and ICEA S-95-658.
Per AREMA Recommended Prac-tice, Section M, RP-588, as applicable andICEA S-95-658.
• Extreme heat resistance.• Extra flexible conductor.• 90°C Continuous Rating,110°C Hot Spot Rating,130°C emergency Overload Rating,300°C Short Circuit Rating.• Mechanically rugged.• Exceptional resistance to deforma-tion and cut through at hightemperature.• Excellent flame resistance. Meetsboth UL vertical and horizontal flametest requirements.• Resistant to oils, weather and mostchemicals and alkalies.• Stable electrical properties at hightemperatures.• Meets the RHH/RHW requirementsof NEC/UL and can be labeled assuch on special orders.
Type DEL
One Copper Conductor/90°C — 110°C Hot Spot Rating
Coated Stranded Copper ConductorSeparator (sizes 36,700 CM andlarger)Insulation - OkoniteJacket - Okolon TS-CPE
B
A
D
Type DEL
One Copper Conductor/90°C - 110°C Hot Spot Rating
� 112-11-1702112-11-1704112-11-1708
002004008
161414
19 X .011719 X .014219 X .0147
223
111
600600
2000
.16
.17
.21
192431
232835
———
182223
1/2”1/2”1/2”
4.4902.7902.790
112-11-1710� 112-11-1714
112-11-1716
010014016
1210
8
19 X .017927 X .020137 X .0201
333
111
20002000
600
.22
.26
.28
405874
446078
—5583
263742
1/2”3/4”3/4”
1.7201.1000.690
112-11-1718112-11-1720112-11-1722
018020022
654
61 X .020191 X .0201
105 X .0201
444
222
200020002000
.38
.44
.46
133182204
141200222
109122145
739198
1”1 1/4”1 1/4”
0.4400.3500.280
112-11-1724112-11-1726112-11-1730
024026030
321
125 X .0201150 X .0201225 X .0201
445
223
200020002000
.48
.53
.68
223278459
241298497
167192223
107125160
1 1/4”1 1/2”2”
0.2200.1800.140
112-11-1732112-11-1734112-11-1738
032034038
1/02/03/0
275 X .0201325 X .0201450 X .0201
555
333
200020002000
.71
.75
.85
504579769
550633842
258298345
184202252
2”2”2 1/2”
0.1100.0900.070
112-11-1740112-11-1744112-11-1748
040044048
4/0313.1444.4
550 X .0201775 X .0201
1100 X .0201
566
333
200020002000
.901.061.20
91212631722
98513711830
400515645
285364450
2 1/2”3”3 1/2”
0.0600.0400.030
112-11-1750112-11-1752112-11-1754
050052054
535.3646.4777.7
1325 X .02011600 X .02011925 X .0201
777
444
200020002000
1.361.451.55
211824902938
226327003148
725815910
493555608
4”4”5”
0.0200.0180.016
112-11-1756112-11-1758
056058
929.21111.1
2300 X .02012750 X .0201
78
44
20002000
1.651.80
33503786
35604072
10251145
664728
5”5”
0.0130.011
� - Available from CustomerService Centers.
- 1000’ Non-Returnable Reel; #16 #8- 1000’ coil in carton; # 6 - 500’ coil in carton; #5 - #4/0 -2000’ N.R. Reel; #313.1 MCM and Larger - 1000’ N.R.Reel
Ampacities based on single conductor in free air, 90°Cconductor temperature, 40°C ambient air temperature perICEA S-75-381.
Three (3) conductors in a single enclosed or exposedconduit. Ampacities based on 90°C conductor tempera-ture and 40°C ambient using ICEA methods. For 30°Cambient multiply values by 1.10; for 50°C multiply by0.90. For other ambients or installation conditions, refer toEngineering Data Book.
Based on three (3) conductors in conduit with a fill of40% or less.
E/11100717
THE OKONITE COMPANYRamsey, New Jersey 07446
ApplicationsThe C-L-X Terminating Tool Kit contains allthe tools required to remove the overalljacket and aluminum sheath from C-L-Xpower, control, and instrumentation ca-bles. The Cable Slitting Saw may also beused on interlocked armor and leadsheathed cables. The Cable Slitting Sawprovides a simple and efficient means ofremoving the aluminum C-L-X sheath. It isavailable in either an electric or a pneu-matic model. Both models have aretractable blade guard to protect the user.The electric model is powered by a 2500rpm, 120 Volt ac double insulated motor. A220 Volt ac model is also available.The lightweight pneumatic model is pow-ered by a 2200 rpm motor which requires90 psi of air pressure for maximum effi-ciency. The Small Cable Guide keeps thesaw centered on the cable when slitting ca-bles of 1” diameter or less.The High Speed Steel Saw Blades providea smooth cut in the aluminum sheath andhave a cutting depth of 3/8” without the ca-ble guide.
Removing the C-L-X ArmorThis procedure applies to all types of C-L-Xarmor - aluminum, copper, bronze andstainless steel. Safe working practices areto be observed, e.g., safety glasses andwork gloves. Practice sessions are recom-mended to familiarize all concerned withthe procedures and equipment.
Remove the jacket to expose the desiredlength of un-armored cable within the en-closure.
Refer to the C-L-X fitting instructions forthe length of C-L-X armor to be exposedbeyond the end of the jacket and markthe C-L-X armor at the top of the crownnearest to that point.
• For C-L-X Diameters 1 5/8” andSmaller, Go To Steps 10 through 12.
• For C-L-X Diameters greater than 15/8” Follow Steps 3. Through 9.
C-L-X Terminating Tool Kit
1 Cable Slitting Saw1 Small Cable Guide
12 2” dia. High Speed Steel Saw Blades1 Tubing Cutter1 Channel Lock Pliers1 10” Retractable Tape
1 5/16” x 11” Screwdriver1 Cable Knife, 4” blade1 Hacksaw Blade Holder3 10” Hacksaw Blades1 Tool Case1 Padlock with 2 keys
C-L-X Terminating Tool Kit
� 606-01-1026� 606-01-1526
Electric - 120 Volt acPneumatic - 90psi
15 1/215 1/2
1616
Cable Slitting Saw, Small Cable Guideand 12 High Speed steel saw Blades
� 606-01-0026� 606-01-0526
Electric - 120 Volt acPneumatic - 90psi
13 1/213 1/2
1414
12 High Speed Steel Saw Blades
� 606-01-5754 2” diameter, 7 teethper inch, packaged ina round tin container
1/2 1/2
� Authorized Stock Item
C-L-X Terminating Tool Kit
First the C-L-X armor will be circumferentially cut using a hack-saw blade, (note the C-L-X saw tool kit is supplied with ahacksaw blade and blade holder) cut through the crown (highpoint) of the C-L-X at an angle so as to connect (or bridge) thevalleys (low points) on both sides of the crown.
Again using a hacksaw blade, make a circumferential score inthe valleys adjacent to the cut crown connecting both sides ofthe crown cut to the valleys. Do not cut through armor in valleys.
Holding the score area rigid, flex the cable by moving the freeend so as to break the score around the circumference of thecable.
Next the C-L-X will be longitudinally cut by performing thefollowing:
- The longitudinal cut is made with theC-L-X saw, which has an adjustable positive depth stop that canbe set so the saw blade cuts through the crowns and partiallycuts through the valleys. A proper saw depth is achieved when80 to 95 % of the metal in the valley is removed. Use an extrapiece of the cable being terminated to adjust the blade depth and
practice.
Set blade to remove 80 to 95% of the metal thick-ness in the valley.
With cable secured, start at the free end of the cable andadvance the Kett saw, making sure to use slight downwardpressure to maintain the depth of cut along the cable, to the ringcut. When advancing the saw, be sure maintain a straight line bycutting along the high point of the cable; this affects the cut depthalso. See following:
If it is necessary to stop cutting or if a portion of the cut is to be re-peated, use caution when reinserting the blade as kickback mayoccur.
At the completion of the longitudinal cut, starting at the free end,insert a wide blade screwdriver into the cut and twist. Repeat un-til the ring cut is reached. This will cause the remaining metal inthe valleys to break open and the armor to loosen on the cable.Do not drive the screwdriver into the cut with excessive force asthis may damage the underlying conductors.
Slide the armor off the cable. In the event that the armor is tightaround the cable, pliers may be used to grab the armor at thesplit and pull it away from the cable. For large diameter cables,where long lengths of armor are to be removed, two cuts spaced180° apart are recommended so that the armor may be removedin two pieces.
• For C-L-X Diameters 1 5/8” and Smaller Follow Steps 10.
Through 13.
Using a hacksaw blade or tubing cutter, circumferentially scorethe C-L-X armor. Grip the cable in both hands with the scorecentered between hands, and flex the cable at the score line untilit opens. Slide the sheath off the cable.
For C-L-X cables with an inner jacket or cable constructionswhere the C-L-X armor is tight fitting around the insulatedconductors, the C-L-X saw should be used with the optional redcolored cable guide. This guide assists in centering the saw onsmall diameter cable. The procedures and precautions of steps3 to 9 apply here also.
Remove the cable fillers and marker tape and install the C-L-Xfitting as per the manufacturer’s instructions. The cable is nowready to be terminated into the enclosure.
THE OKONITE COMPANYRamsey, New Jersey 07446E/14020605
Correct Incorrect
NOTES
NOTES