bunbury regional entertainment centre theatre techspecs08 · bunbury regional entertainment...

16
Generated from the APACA Technical Specifications Template. For more details visit www.apaca.com.au Bunbury Regional Entertainment Centre Bunbury Regional Entertainment Centre Technical Specifications Updated 21/02/08 Technical Manager: Paul Parkes Phone number: 08-9791 1133 Mobile Number: 0427 387 502 Fax number: 08-9792 3122 Email address: [email protected] Venue: Phone number: 08-9791 1133 Fax number: 08-9792 3122 Website: www.bunburyentertainment.com

Upload: vubao

Post on 05-Nov-2018

254 views

Category:

Documents


2 download

TRANSCRIPT

Generated from the APACA Technical Specifications Template. For more details visit www.apaca.com.au

Bunbury Regional

Entertainment Centre

Bunbury Regional Entertainment Centre

Technical Specifications

Updated 21/02/08

Technical Manager: Paul Parkes

Phone number: 08-9791 1133 Mobile Number: 0427 387 502 Fax number: 08-9792 3122 Email address: [email protected]

Venue:

Phone number: 08-9791 1133 Fax number: 08-9792 3122 Website: www.bunburyentertainment.com

Bunbury Regional Entertainment Centre_Theatre_Techspecs08.doc

Page 2 of 16

STAGE

Brief Stage Description: Unraked stage with proscenium arch and false proscenium arch. Hardwood floor with Masonite cover. Screwing into stage permitted but larger holes must be authorised by Technical Manager. Stage crossover behind u/s fly line. Stage has bastard prompt and stage manager position either o/p or p/s.

Stage distributed load limit Not known Stage point load limit Not known Stage rake No

Stage Dimensions: Proscenium

Width 13.7m

Height 6.8m

Setting Line 880mm from d/s edge.

Distance From (SL = Setting Line, CL = Centre Line) SL to DS edge of apron 880mm SL to DS edge of Orchestra Lift/Pit 5380mm

SL to first fly line 600mm

SL to last upstage fly line 9.6m

SL to rear wall 11m

CL to OP wall (or obstruction) 13.7m

CL to PS wall (or obstruction) 10.2m

Stage to underside of grid 15m

Overhead obstructions 1st Gallery = 7.1m

2nd Gallery = 13.2m

Auditorium: Auditorium consists of stalls and 1 balcony level. Audio booth at rear of stalls comprising 18 seats.

Seating capacity with additional Orchestra lift/pit seating installed 792

Seating capacity without Orchestra lift/pit seating installed 721

Bunbury Regional Entertainment Centre_Theatre_Techspecs08.doc

Page 3 of 16

Orchestra Lift / Pit: Orchestra Pit

Motorised Orchestra Lift is operational. Serapid System. 1 person operation. Set positions for orchestra lift where lift at auditorium level is 0mm

Stage level at 1200mm above auditorium.

Orchestra pit level at 1800mm below auditorium.

Lift can be set at any height Yes

SWL of orchestra lift Not Known

Dimensions of the orchestra pit 14.4m x 4.4m Orchestra pit maximum capacity Approx. 50 chairs

Flying Facilities: Fly System

Single purchase counterweight handline system.

Fly System Details Operating Position P/S at stage level. Total number of Lines 46 Panorama Lines 1 fixed line o/p, 1 fixed line p/s Batten Drift 13.5m

Batten Type 50mm o/d pipe. Batten Length 16m Batten Extensions N/A

Batten Pick-ups 4 pick ups. 2m from end of batten then 4m to next pick up. Batten Point Load Not Known

Batten W.L.L. 350kg

Cradle Capacity Refer to hanging plot for details. LX bars can be swung No Fly bars can be swung Yes

SEE HANGING PLOT FOR LINE ALLOCATIONS AND FURTHER INFO

Bunbury Regional Entertainment Centre_Theatre_Techspecs08.doc

Page 4 of 16

Hanging Plot: SL: Setting Line as indicated previously Line Type: SP = Single purchase, DP = Double purchase, MW = Motor Winch, HW = Hand Winch, HL = Handline W.L.L.: Maximum distributed load including bar weight

Line # Distance from SL

Line Type W.L.L Venue Allocation

Intended Use (hiring company use)

H.C. 1.195m HL 600kg Not Available for use Pelmet 1.430m HL 350kg Not Available for use

1 1.6m HL 350kg 2 1.79m HL 350kg LX-1 Lighting Bar 3 1.975m HL 350kg ¾ Bar 4 2.150m HL 350kg 5 2.335m HL 500kg Cinema Screen Not Available for use 6 2.515m HL 350kg #1 Legs 7 2.69m HL 350kg 8 2.98m HL 350kg 9 3.16m HL 350kg

10 3.34m HL 350kg 11 3.52m HL 350kg #1 Border 12 3.7m HL 350kg #2 Legs 13 3.88m HL 350kg 14 4.06m HL 350kg ¾ Bar 15 4.245m HL 350kg LX-2 Lighting Bar 16 4.428m HL 350kg 17 4.6m HL 350kg 18 4.78m HL 350kg #3 Legs 19 4.965m HL 350kg 20 5.255m HL 350kg 21 5.44m HL 350kg 22 5.62m HL 350kg 23 5.8m HL 350kg #2 Border 24 5.98m HL 350kg #4 Legs 25 6.13m HL 350kg 26 6.41m HL 350kg 27 6.595m HL 350kg LX-3 Lighting Bar 28 6.775m HL 350kg 29 6.955m HL 350kg 30 7.135m HL 350kg French Action Tab 31 7.315m HL 350kg 32 7.59m HL 350kg 33 7.77m HL 350kg 34 7.95m HL 350kg 35 8.13m HL 350kg #3 Border 36 8.31m HL 350kg #5 Legs 37 8.49m HL 350kg 38 8.67m HL 350kg LX-4 CYC Lighting Bar 39 8.85m HL 350kg 40 9.035m HL 350kg 41 9.215m HL 350kg 42 9.395m HL 350kg 43 9.575m HL 350kg 44 9.875 HL 350kg 45 10.18m HL 350kg French Action Tab 46 10.475m HL 350kg Cyclorama

Bunbury Regional Entertainment Centre_Theatre_Techspecs08.doc

Page 5 of 16

Drapery:

*Type Material Colour Width Height Quantity House Curtain Red 13000mm 7000mm 1 Borders Wool Black 13000mm 6000mm 4

Legs Wool 50% Gather

Black 3000mm 6000mm 5 (pairs)

Tabs / Smother Wool 50% Gather

Black 15000mm 6000mm 2

Cyclorama Cotton White 15000mm 6000mm 1 Scrim Gauze White 15000mm 6000mm 1

Access Equipment: Elevated Work Platform

JLG Elevated work platform. Electric.

Maximum reach is 5.94m EWP Restrictions

One extra staff member to be present whilst in use.

Ladders (1) 4.8m Aluminium (Not for electrical use).

(1) 3.5m Fibreglass (1) 2.2m Fibreglass (1) 1.8m Aluminium (Not for electrical use).

Staging Units: (7) Steel Rostra, 1800x1200x300

(7) Steel Rostra, 1800x1200x600

(7) Steel Rostra, 1800x1200x900

Stage Covers: Style Tarquet Dimensions (6) Rolls, 12m x 2m Colour Two Sided, one side black, one side white.

Stage Traps: (1) Stage Trap located 2420mm 2420mm upstage of setting line.

Trap dimension is 1300mm x 1200mm. Use must be authorised by the Technical Manager.

Safety Curtain: Safety Curtain installed No

Safety Curtain must be unobstructed at all times N/A

Thickness of Fire Curtain N/A

Distance from setting line N/A Additional Requirements

N/A

Bunbury Regional Entertainment Centre_Theatre_Techspecs08.doc

Page 6 of 16

Loading Dock: Access

Truck access via car park off Victoria St. Truck must enter forwards and then reverse to loading dock. Loading Dock Height 700mm Door Dimensions 3m High

2.4m Wide

Restrictions / Obstructions At the loading dock roller door there is a 1 inch ridge acting as a water barrier.

Additional Rigging Notes Rigging points from grid, forestage, etc with load limits and access.

Staging Notes: All flown items must be rigged with rated equipment and is subject to approval by a venue representative.

Limited rigging gear in house. Droppers, shackles and flat lifters.

Access to galleries from P/S or O/P.

Bunbury Regional Entertainment Centre_Theatre_Techspecs08.doc

Page 7 of 16

LIGHTING

Positions: Stage LX Bars LX bars can be brailed up to 1m from standard position.

See hanging plot for standard LX bar locations

Orchestra Bar Setting Line to lighting bar N/A

FOH Bridge #1 Setting Line to lighting bar 6680mm @ 60 deg. Usable bar width 14m Notes 18 Selecon Pacific 23-50 Deg. Zoomspots as Standard.

FOH Bridge #2 Setting Line to lighting bar 12120mm @ 30 deg. Usable bar width 14m Notes 22 Selecon Pacific 12-28 Deg. Zoomspots as Standard.

Balcony Bar

Setting Line to lighting bar 14620mm @ 5 deg. Usable bar width 9m

FOH Perches (PS & OP) Setting Line to FOH Perch 2420mm @45-60 deg. Distances are to the highest downstage point of boom or perch. Maximum lanterns per perch 6 Selecon Acclaim Zoomspots 650w as Standard.

FOH Booms (PS & OP) Setting Line to FOH Boom 2420mm @ 5 deg. Distances are to the highest downstage point of boom or perch.

Maximum lanterns per boom Maximum 4 x Selecon Acclaim Zoomspots 650w.

Control: Lighting desk Strand 520i. Jands Event 408 for moving light control.

Control channels 512

Signal output DMX 512

Signal distribution 3 streams of DMX 512. Stream A to dimmers, Stream B to various points, Stream C to Opto Isolator.

Remote riggers available onstage Yes

Bunbury Regional Entertainment Centre_Theatre_Techspecs08.doc

Page 8 of 16

Dimmer Racks: Total Dimmers 10 Dimmers comprising 120 channels. Dimmer Locations Patch Bay located o/p gallery.

2.4Kw Dimmer Racks Bytesize 2.5kW Total dimmers @ 2.4kw per dimmer 120

5Kw Dimmer Racks N/A Total dimmers @ 5kw per dimmer N/A

House Lights: Independant control Yes Control positions Beside lighting desk or P/S of stage. Fade time adjustable No.

Stage Luminare: Profiles Make Model Angle Detail / Accessories Watt Total Selecon Pacific 23-50 2 x 80v Transformers 1200 18 Selecon Pacific 12-28 1200 22 Selecon Acclaim 23-50 650 30

Fresnel’s Make Model Detail / Accessories Watt Total Selecon 1200 Barn Doors 1200 40

Par Cans Make Model Angle Detail / Accessories Watt Total Selecon Multi-Par Variable Barn Doors 575 24

Wash Make Model Detail / Accessories Watt Total Selecon Aurora 4 lamps per unit 1000w each 6

Movers

Make Model Control Channels Detail / Accessories Watt Total

Martin Entour 250 16 Wide Angle Lens 250 4 Martin 250 Wash 11 Frosted Lens 250 4 Martin 600E 11 575 4

Followspots:

Make Model Angle Detail / Accessories Watt Total Xenon 700SR Colour Changer 700 2

Bunbury Regional Entertainment Centre_Theatre_Techspecs08.doc

Page 9 of 16

Additional Lighting:

Item Make Model Detail / Accessories Watt Total Mirror Ball 600mm Dia. Motorised 1 Strobes Geni FL-1800D DMX Controlled 2700 2 Blacklight UVA-400 Non-Dimmable 400 1 Scrollers Diafora Up to 30 Colours 4 Sconce 10 25 DMX Slitters Jands DD-8 2

Patching:

Location Quantity Numbering (PS to OP)

Detail / Accessories

FOH Bridge #1 16 15-32 FOH Bridge #2 14 1-14 LX-1 20 39-58 LX-2 18 59-76 LX-3 18 77-94 LX-4 14 95-108 Perch O/P 3 33-35 Perch P/S 3 36-38 Box Boom O/P 2 235-236 Box Boom P/S 2 231-232

Power: 3 Phase Outlets

3 x 50 amp outlets O/P side in workshop. 1 x 50 amp outlet under stage P/S

Cabling: 240v Extension Cable

Theatre has good stock of 10amp extension leads from 1 to 20m. Good stock of DMX extensions.

Looms 2 x 15m 6 way looms with Wieland headers.

3 phase Extensions 2 x 30m 3 Phase extensions

Lighting Notes: We carry as standard a comprehensive selection of LEE colour.

6 x Lighting Ladders in stock with 6 slots each.

Bunbury Regional Entertainment Centre_Theatre_Techspecs08.doc

Page 10 of 16

AUDIO

Control Positions:

Control Room Control Room behind sliding glass panels. Dedicated position, no seats pulled.

Auditorium

Located rear of stalls, centre of rows Q+R. (Standard position).

Total seat allocation 18

Other Stage Managers console. Mixer patched through main system.

Control & Amplification: Primary Mixer

Yamaha M7/CL48 Digital Mixing Console, 48 Channel, 4 Stereo in Channels.

16 mix Channels, 8 Matrix Channels a stereo and a mono Channel.

L/C/R output using Stereo/Mono Channels supported.

Secondary Mixer Dynacord Powermate 1600, 2 x 550 watts. 16 Channels, 2 x stereo inputs, 4 x Aux. Sends, phantom power.

Amplifiers (7) E.V. P300 Power Amp. 850 watts @ 8 ohms. (2) DBX 481 Driverack. (1) Crest Audio CA9 Power amp.

EQ (1) DBX 48R Driverack.

FX Internal on Console Compression / Limiter / Gates

Internal on Console

Speakers: FOH Speakers

EV XI 1122. 2 per side. EV XI 2181 Single sub per side. EV XI 1122 Centre Cluster mounted side by side.

Foldback (6) EV SX300 on 4 sends powered by (2) EVP 2000. (4) EV ZX 500.

Bunbury Regional Entertainment Centre_Theatre_Techspecs08.doc

Page 11 of 16

Playback

Item Make Model Detail Total CD Player Denon C680 Pro CD Player 1 CD Player Marantz Cdr 631 CD Player and burner 1 Minidisk Sony MDS E12 Minidisk Recorder 1

Microphones

Make Model Detail / Accessories Use Total Shure SM58 Pop Guards and Clips. Vocal 5 Shure Beta SM 58 Vocal 2 Shure SM 57 Vocal/Inst. 4 AKG 451 Inst. 4 AKG D112 Kick 1 Shure Beta58A Radio Vocal 4 EV 391 Plate 2 EV RE90 Choral 4 Rode NTG-1 Vocal/Inst. 5

Accessories:

Item Model Detail / Accessories Total Microphone Stands Half Size Floor stand with boom 8 Microphone Stands Full Size Floor stand with boom 12

Line Patching:

Location Quantity Numbering Detail Dip Traps (foldback) 9 n/a 4 mic, 2f/back per trap.

Speaker Patching:

Location Quantity Numbering Detail Dip Traps 2 x f/back each 5

Cabling: Audio Cable

The theatre has a good stock of cable to accommodate the venues equipment.

Multicore (2) 8m Multi-core, 1 x 6 line+ 1 x 8 line.

Audio Notes: Control position not recommended for live mixing. Recommend using auditorium position with removal of 18 seats to accommodate console and operator (standard).

Bunbury Regional Entertainment Centre_Theatre_Techspecs08.doc

Page 12 of 16

AUDIO VISUAL

Projection Room: Dedicated room rear of auditorium.

Projectors:

Type Model Detail / Accessories Total Monee 35mm projector Cannot be relocated 1 NEC Data Projector LT 260 Can be moved 1 NEC Data Projector NP2000 Can be moved. Wide angle lens. 1

Screens: Projection Screen

Front projection Cinema screen permanently rigged from line 5.

Screen dimensions 10m x 6m with tab track for all formats.

Additional Screens N/A

AV Playback Equipment:

Item Model Detail / Accessories Total JVC DVD XV-N422 Single DVD player with record functions. 1 LG DVD DZ9811P Single DVD Player 1

Projector Rigging Points: Projector has a mounting assembly and can be rigged from any horizontal lighting bar.

Cabling: The theatre has access (hire) to full stock of coaxial and RCA/VGA cabling.

Audio Visual Notes: We also have dedicated cinema audio system. 3 x XEQ 504A Crossover and 2 x JBL Subs.

Bunbury Regional Entertainment Centre_Theatre_Techspecs08.doc

Page 13 of 16

BACKSTAGE

Communications: Stage Managers Desk

Stage managers desk can be located either O/P or P/S. Desk can be fitted with CD player and 8 channel audio desk patched through the main system.

Talkback Master Unit Located o/p d/s corner. Two common loops. Total sub stations 6

Total headsets 8

Radio Units In-house Nil Talkback patching located at: FOH Audio

P/S D/S Corner O/P D/S Corner Fly Lines D/S O/P Wing U/S Bio Box. 4 Patch Points FOH Bridge #1 FOH Bridge #2 Gallery #1

Paging / Show relay Paging master unit is located in O/P D/S corner. Paging is to all dressing rooms, rehearsal room and green room. Each area has individual volume control.

Stage Monitor Stage monitors are located in O/P D/S corner, rehearsal room, green room and foyer. Camera is located on centre of balcony bar.

Q Light System In house Q light system available No

Number of units N/A

Dressing Rooms:

Dressing Room Capacity Toilets Shower Details Dressing Rm #1 16 4 Yes Dressing rooms have lit mirrors. Dressing Rm #2 4 1 Yes Dressing Rm #3 4 1 Yes Dressing Rm #4 16 4 Yes

Laundry / Wardrobe: Washing Machines 1 Dryers 1 Drying rooms No Iron / ironing board 1

Clothes racks 4

Bunbury Regional Entertainment Centre_Theatre_Techspecs08.doc

Page 14 of 16

Production Facilities: Production Desk

Production Desk is folding table set-up in middle of stalls. Table accommodates 2 people. DMX and Talkback are run from P/S D/S corner.

Production Office No

Phone Access to phone in Technical Managers office.

Fax Fax available on request from front office.

Access to phone for internet access Phone point for internet from inside stage door entrance. Ethernet extension available.

Greenroom: Tea / Coffee facilities Yes

Fridge / freezer No

Microwave Yes Running water Yes

Stage Door: Access

Stage door is located next to loading dock. Access controlled at all times by senior technician.

ADDITIONAL FACILITIES & INFORMATION

Orchestral: Steinway ‘D’ Series Concert Grand available. Tuning to be arranged prior to arrival.

Yamaha upright available.

30 Music stands.

30 Padded grey chairs for on-stage seating.

(5) 10 amp GPO outlets all on individual circuits.

Rehearsal Space: Rehearsal Room available. Approx. 12m x 6m. Full mirrored wall for dance rehearsal.

Portable CD Player available on request.

Hire Stock; We have a comprehensive range of theatre lamps available for hire. Including wide and narrow profiles, 1k + 2k Fresnels.

Bunbury Regional Entertainment Centre_Theatre_Techspecs08.doc

Page 15 of 16

VENUE:

Venue Contacts: Venue Address Cnr. Blair and Symmons St. Bunbury. Venue Postal Address P.O. Box 1983 Bunbury 6231

Staff Contacts: Technical Manager Paul Parkes

Mobile 0427 387 502 Email Address [email protected] Phone Number 08-9791 1133

Head of Staging Matt Fletcher Mobile 0417 907 973 Email Address [email protected] Phone Number 08-9791 1133

Head of Audio Geoff Dent Mobile 0438 709 062 Email Address [email protected] Phone Number 08-9791 1133

Administration Matara Merrit Phone Number 08-9792 3111 Email Address [email protected] Fax Number 08-9792 3122

Box Office Peta Bazzo Phone Number 08-9791 1133 Email Address [email protected] Fax Number 08-9792 3122

Stage Door Phone Number N/A

Stage Phone Number N/A

Venue Plans: Venue Plan Available

Yes. Hard copy at 1:50 can be mailed. A DWG file can be e-mailed on request. Plan is available for download from APACA website.

Venue Section Available Yes. Hard copy at 1:50 can be mailed. A DWG file can be e-mailed on request.

Bunbury Regional Entertainment Centre_Theatre_Techspecs08.doc

Page 16 of 16

Venue Information: The venue is centrally located in Bunbury CBD. Accommodation, hotels, take away food and restaurants are all within 2 minutes walk of the centre. A core staff of 7 run the centre which is council funded. The Bunbury Regional Entertainment Centre operates 1 performance space. We also run the venue as a Cinema and program 2 international film festivals per year.