bus ethernet gateway - control 4...storage -4˚f to 158˚f (-20˚c to 70˚c) heat dissipation 4.7...

2
BUS ETHERNET GATEWAY CENTRALIZED LIGHTING The Bus Ethernet Gateway is the connection point for all wired keypads and other devices on the Control4 Centralized Lighting keypad bus. The Ethernet Gateway is designed to convert RS-485 communication to Ethernet for usage with Centralized Lighting modules and a Control4 controller. • Connection point for wired keypads and other devices on the RS-485 bus • Converts keypad bus communication to Ethernet Installs in either the Control4 5-Slot or 2-Slot Panel or a third-party DIN rail panel • Powered by the 48V Bus Power Supply • See the Keypad Bus Wiring Guide (ctrl4.co/buswiring) for details on maximum number of devices per gateway CONTROL4® BUS ETHERNET GATEWAY C4-DIN-BEG-V2

Upload: others

Post on 04-Mar-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: BUS ETHERNET GATEWAY - Control 4...Storage -4˚F to 158˚F (-20˚C to 70˚C) Heat dissipation 4.7 BTU/hr @48VDC Humidity 5% to 95% non-condensing Connections Ethernet (1) RJ-45 for

BUS ETHERNET GATEWAYCENTRALIZED LIGHTING

The Bus Ethernet Gateway is the connection point for all wired keypads and other devices on the Control4 Centralized Lighting keypad bus. The Ethernet Gateway is designed to convert RS-485 communication to Ethernet for usage with Centralized Lighting modules and a Control4 controller.

• Connection point for wired keypads and other devices on the RS-485 bus• Converts keypad bus communication to Ethernet• Installs in either the Control4 5-Slot or 2-Slot Panel or a third-party DIN rail panel• Powered by the 48V Bus Power Supply• See the Keypad Bus Wiring Guide (ctrl4.co/buswiring) for details on maximum number of devices per

gateway

CONTROL4® BUS ETHERNET GATEWAYC4-DIN-BEG-V2

Page 2: BUS ETHERNET GATEWAY - Control 4...Storage -4˚F to 158˚F (-20˚C to 70˚C) Heat dissipation 4.7 BTU/hr @48VDC Humidity 5% to 95% non-condensing Connections Ethernet (1) RJ-45 for

Copyright ©2018, Control4 Corporation. All rights reserved. Control4, the Control4 logo, the 4-ball logo, 4Store, 4Sight, Control4 My Home, and Mockupancy are registered trademarks or trademarks of Control4 Corporation or its subsidiaries in the United States and/or other countries. All other names and brands may be claimed as the property of their respective owners. All specifications subject to change without notice.

201-00003-C.1 07-26-2018 LW

CONTROL4® BUS ETHERNET GATEWAY

Model number C4-DIN-BEG-V2

Power input 24-48VDC

Power consumption 1.0W

Control communications 10/100 Ethernet

Environmental

Operational temperature 32˚F to 104˚F (0˚C to 40˚C)

Storage -4˚F to 158˚F (-20˚C to 70˚C)

Heat dissipation 4.7 BTU/hr @48VDC

Humidity 5% to 95% non-condensing

Connections

Ethernet (1) RJ-45 for control communications

Terminal blocks (4) pluggable blocks for keypad bus wiring

Recommended wiring gauge 36 AWG to 14 AWG (0.14 mm2 to 1.5 mm2)

Dimensions

H × W × D 4.28 × 4.48 × 2.15 in. (108.6 × 113.9 × 54.6 mm)

DIN module width 6M

Weight 1.20 lbs (0.54 kg)

Shipping weight 1.55 lbs (0.70 kg)

C4-DIN-BEGBus Ethernet Gateway

Reset

ID Status

Link/Activity

GN

D

V D D-++

GN

D

V D D-++

GN

D

V D D-++

GN

D

V D D-++

Made in China/Fabriqué en Chine/中国制造

This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

CAN ICES-3 (B)/NMB-3(B)

4.4

8"

113.9

cm

4.28" 108.6 cm

Dimensions

MOST RECENT VERSION

ctrl4.co/ethgwy-ds

48V BUS WIRING GUIDE

ctrl4.co/buswiring