This new and improved isolation guard prevents animal-caused outages in electrical substation equipment. Reliable outage prevention: BISG II discs have been successfully eliminat- ing outages from squirrels, raccoons, opos- sums, cats, and other animals in substations for years. The new BISG II guard has been designed to provide the same great protection with added features. Same high performance material: Superior high voltage outdoor materials are used in the new BSIG II guard design. The rugged, non-tracking, UV-resistant polymer ensures long-term performance even in the most extreme environmental conditions. Faster, easier installation: The BISG II guard allows easier hotstick installation by incorporating a threaded area in the guard. The integrated threads eliminate the need to hold a nut while installing the bolt assembly with a hotstick. The bolted design positively and tightly secures the device onto the insulator or bushing, eliminating loosening or drooping caused by wind, snow, ice, or animals. Expanded size range: The BISG II guard now fits insulator core diameters ranging from 1”(25mm) through 4.5” (115mm) from the factory. The new “grill” type design allows easy field modifications for even larger diameters (see your local Tyco Electronics representative for details). The BISG II guard can also have its outside diameter reduced by trimming along the grill ribs. This will allow the guard to fit in tight phase-to- phase insulator applications. “Invisible” appearance: The new BISG II design gives the same protec- tion as the old guard without the noticeable profile. The “invisible” design allows easier visibility of switch blades and other equipment components through the guard. BISG II Bus Insulator Squirrel Guard

Upload: hathuy

Post on 06-Mar-2018

220 views

Category:

Documents


2 download

TRANSCRIPT

This new and improved isolation guard prevents animal-caused outages in electricalsubstation equipment.

Reliable outage prevention:BISG II discs have been successfully eliminat-ing outages from squirrels, raccoons, opos-sums, cats, and other animals in substationsfor years. The new BISG II guard has beendesigned to provide the same great protectionwith added features.

Same high performance material:Superior high voltage outdoor materials are used in the new BSIG II guard design. Therugged, non-tracking, UV-resistant polymerensures long-term performance even in themost extreme environmental conditions.

Faster, easier installation:The BISG II guard allows easier hotstick installation by incorporating a threaded area in the guard. The integrated threads eliminate the need to hold a nut while installing the bolt assembly with a hotstick. The bolteddesign positively and tightly secures the deviceonto the insulator or bushing, eliminating loosening or drooping caused by wind, snow,ice, or animals.

Expanded size range:The BISG II guard now fits insulator core diameters ranging from 1”(25mm) through4.5” (115mm) from the factory. The new “grill”type design allows easy field modifications foreven larger diameters (see your local TycoElectronics representative for details).

The BISG II guard can also have its outside diameter reduced by trimming along the grillribs. This will allow the guard to fit in tightphase-to- phase insulator applications.

“Invisible” appearance:The new BISG II design gives the same protec-tion as the old guard without the noticeableprofile. The “invisible” design allows easier visibility of switch blades and other equipmentcomponents through the guard.

BISG IIBus Insulator Squirrel Guard

© 2

00

0 T

yco

Elec

tron

ics

Cor

pora

tion

Prin

ted

in U

SA

13

08

24

5

E

13

1.8

/00

www.tycoelectronics.com

All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should independently evaluate the suitability of each product for the desired application. Under no cirumstances does this constitute an assurance of any particular quality or performance.Such an assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for this product is set forth in our standard terms and conditions ofsale. BISG is a trademark of Tyco Electronics Corporation.

Tyco Electronics RaychemEnergy Division8000 Purfoy Road Fuquay-Varina, NC 27526-9349Phone: 1-800-327-6996Fax: 1-800-527-8350

•Wedge technology products•Electrical connectors•Cable accessories•Overhead conductor hardware•Asset protection•Surge arresters•Insulators•Fittings•Associated tooling

ArgentinaPhone: 54-11-4733 2277Fax: 54-11-4733 2267

AustraliaPhone: 61-2-4390 1111Fax: 61-2-4353 2497

BrazilPhone: 55-11-861 1311Fax: 55-11-861 1862

CanadaPhone: 1-905-475 6222Fax: 1-905-470-4453

FrancePhone: 33-3-80583200Fax: 33-3-80341015GermanyPhone: 49-89-6089-0 Fax: 49-89-6096345

MexicoPhone: 52-5-729 0405Fax: 52-5-361-8545

ThailandPhone: 66-2-7394026 - 32Fax: 66-2-3260563 - 64

Product Performance

Product Test RequirementPower Arc (14.4 kV RMS Test Current: 10 kA RMS 10 cycles) No evidence of burns or flames Ice Flashover/ Contamination Insulator with BISG guard must demonstrate a flashover value within

90% of controlImpulse/ BIL Does not significantly alter electrical characteristic of insulatorAC Dry Withstand on disconnecting switch 15 kV minimumWind Tunnel (70 MPH for 10 minutes) No dislodging of BISG guard from insulator location

Key Material Properties Test Method RequirementPhysicalTensile Strength ASTM D638 17 Mpa min. (2450 psi min.)Ultimate Elongation ASTM D638 25% min.

ElectricalTracking and Erosion ASTM 2303 No tracking or erosion to top surface or flame

Resistance Step Voltage Method Failure after: 1hr. @ 2.5kV, 2.75kV, 3.00kV(initiate @2.5kV) and 20 min. @3.25 kV

Product Selection

Product Type Insulator Range Standard PackBISG-60/115-02-(S10) 1.0”-4.5” (60mm-115mm) 10

Technical Reports

EDR-5310 - Bus Insulator Squirrel Guard (BISG-60/115-02-FT) Mechanical/Electrical Evaluation

Convenient, reliable protection for bareconductors

Outage prevention:The MVLC, Medium Voltage Line Cover, providesstate-of-the-art insulation to help preventelectrical outages caused by trees or wildlifecoming into contact with distribution lines.

Cost-effective:The MVLC cover is designed to insulate existingbare lines without costly conductor replacementexpenditures or additional line hardware. TheMVLC cover may be applied selectively onproblem spans.

Live, consistent installation:Tyco Electronics has designed a special tool thatensures fast and reliable application of the MVLCcover. The tool allows application on energizedlines. It attaches directly to the overheadconductor and remains stationary in a singlelocation on each span. The tool may be manuallyor automatically operated, using a hand crank orwith the aid of a power drill. The tool forms,closes, and feeds the MVLC cover along theconductor with speed and consistency.

Wide use range:

One size covers conductors from #2 - 397 kcmil

(50-185 mm2).

Higher performance product available:

A mastic sealed version of the product is available

for 25kV or higher performance at 15kV.

High voltage material:The MVLC material formulation is based on 25+ years of field-proven experience with HVproducts in harsh environments. The highdielectric strength MVLC material is UV stable aswell as tracking and erosion resistant. The MVLCcover is electronically cross-linked to create anextremely robust insulation system ensuringmany years of reliable operation in the harshestenvironments.

MVLCMedium Voltage Line Cover

© 2

00

0 T

yco

Elec

tron

ics

Cor

pora

tion

P

rinte

d in

US

A

1

30

83

77

E1

13

.9/0

0

www.tycoelectronics.com

All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should independently evaluate the suitability of each product for the desired application. Under no cirumstances does this constitute an assurance of any particular quality or performance.Such an assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for this product is set forth in our standard terms and conditions ofsale. Raychem and MVLC is a trademark of Tyco Electronics Corporation.

Tyco Electronics Raychem Energy Division8000 Purfoy Road Fuquay-Varina, NC 27526-9349Phone: 1-800-327-6996Fax: 1-800-527-8350

•Wedge technology products•Electrical connectors•Cable accessories•Overhead conductor hardware•Asset protection•Surge arresters•Insulators•Fittings•Associated tooling

ArgentinaPhone: 54-11-4733 2277Fax: 54-11-4733 2267

AustraliaPhone: 61-2-4390 1111Fax: 61-2-4353 2497

BrazilPhone: 55-11-861 1311Fax: 55-11-861 1862

CanadaPhone: 1-905-475 6222Fax: 1-905-470-4453

FrancePhone: 33-3-80583200Fax: 33-3-80341015

GermanyPhone: 49-89-6089-0 Fax: 49-89-6096345

MexicoPhone: 52-5-729 0405Fax: 52-5-361-8545

ThailandPhone: 66-2-7394026 - 32Fax: 66-2-3260563 - 64

Product Performance

Test MVLC-18-A/U / MVLC-18-A/241 (sealed)

AC withstand (dry) - 1 minute 15 kV min. / 25 kV min.

AC withstand (wet) - 1 minute 15 kV min. / 25 kV min.

AC long term withstand (dry) - 4 hours 8.6 kV min. / 14.4 kV min.

30 day thermal loading (8 hr @ 130°C; 16 hr off) No MVLC deformation

Conductor ampacity 82-89% of bare conductor ampacity

Key material properties Test method RequirementPhysical Tensile Strength ASTM D638 10 MPa min., 1450 psi min.

Ultimate Elongation ASTM D638 200% min.Abrasion Resistance 1000 cycles, 2068g 20% max. thickness lossLow Temperature Impact ASTM D746 No cracking at -20°C

Electrical Dielectric Strength ASTM D149 217 kV/cm @ 1.27 mm min.550V/mil @ 0.050" min.

Tracking and Erosion ASTM D2303 No tracking or erosion Resistance Step Voltage Method to top surface or flame

(Initiate @ 2.5 kV) failure after: 200 minutesChemical Water Absorption ASTM D570 1% max after 336 hrs. at 23°C

Resistance to bird guano Uric acid for 168 hrs @ 60°C-Tensile Strength 10 MPa min, 1450 psi min.-Ultimate Elongation 100% min.

Resistance to Cable Grease 168 hrs @ 60°C-Tensile Strength 10 MPa min, 1450 psi min.-Ultimate Elongation 100% min.

Thermal Accelerated Aging ASTM D2671 168 hours at (150±2)°C-Tensile Strength 10 MPa min, 1450 psi min.-Ultimate Elongation 100% min.

Thermal Endurance IEC 216 105°C min.

Product SelectionProduct Size Conductor Size Weight

MVLC-18 50 - 185 mm2 (#2 - 397kcmil) 0.4kg/m (0.27 lbs/ft)

Ordering InformationVoltage Class Description UOM: m (ft) Spool Length Installation Tool

15 kV MVLC-18-A/U 75m (245 ft) MVLC-18-TOOL-01

25 kV (sealing mastic in receptacle) MVLC-18-A/241 75m (245 ft) MVLC-18-TOOL-02-241

Notes: Hand Tool Description: MVLC-HAND-TOOL-01Hydraulic Drill Description: MVLC-HYDRAUL-DRILL

Technical ReportsEDR-5308 MVLC Electrical TestingEDR-5309 MVLC Material Qualification to PPS 3010/42EDR-5316 Summary of Wind and Ice/Snow Load Testing of MVLC at EA Technology

OLICR

Overhead line insulating channelVoltage classes 15/24 kVConductor Ø 4 – 25 mm

Product descriptionOLIC is a ‘clip-on’ insulating channel whichprovides flashover protection for overheadlines.

Installation of OLIC prevents power outagesfrom swinging conductors and intermittentcontact with birds, animals and trees.

OLIC is made from a track-resistant, cross-linked polymer of high dielectric strength.

Installation is simple, requiring no heat and no tools, making OLIC ideal for retrofit applications.

OLIC-O sections clip over the conductor andare held in place with UV stabilised plastic tie-wraps.

OLIC-C sections clip over the conductor and are held in place with a removable and re-usable closure rail.

ApplicationsOLIC-O and OLIC-C are suitable for use onoverhead line conductors with diameter from 4 mm to 25 mm.

Both channels are available in 1 m and 3 m lengths. These can be cut easily to form a range of shapes and linked together to form long lengths.

OLIC has passed test programmes set byRaychem and utilities for applications up to 15 kV (OLIC-O) and 24 kV (OLIC-C).

Live-line workingOLIC-O has been installed by one large utilityusing live-line working techniques.

Features/benefits• Clip-on, tool-free installation allows easy

retrofit application

• Modular design permits re-enterable and re-usable applications

• High dielectric strength provides good protection against accidental line flashovers

• UV-resistance and weather resistance givesmaintenance-free lifetime

• Raychem’s high voltage test programmeassures long term reliability

• Mechanically robust polymer design is lightweight and vandal-resistant

OLIC DB UK 31.01.2000 12:53 Uhr Seite 1

Overhead line insulating channelKey product specifications Test method RequirementTensile strength (TS) ISO 37, ASTM D638 10 MPa min.Ultimate elongation (UE) ISO 37, ASTM D638 300% min.Dielectric strength IEC 243, ASTM D149 130 kV/cm min. @ 2 mmComparative tracking index IEC 112, VDE 0303/1 KA 3cLow temperature ASTM D2671 No crackingflexibility Procedure C after 4 hrs @ -40°CThermal endurance IEC 216, IEEE 1-1969 105°C min.Flammability ANSI C37.20/IEEE-27 No flame conveyance

(60 sec max.)Smoke index NES 711 Less than 50Weathering resistance ASTM G53 Less than 20% reduction in

UE after 5000 hrsResistance to bird guano Uric acid for 168 hrs @ 60°C No change in TS or UENote: For further product specification information see Raychem PPS 3010/25.

Product selection/ordering information

Ordering Dimension H Dimension W UOM: one piece of lengthdescription nom. min. (m)OLIC-O-1000 85 1.5 1.0OLIC-O-3000 85 1.5 3.0OLIC-C-1000 76 1.5 1.0OLIC-C-3000 76 1.5 3.0Note: Dimensions in mm unless otherwise stated. Installation instructions EPP 0627 5/96 and Material Safety Data Sheet available on request.

Technical reports UVR 8193 – Product qualification report for OLIC-C and OLIC-O

OLIC

W

W

HH

© R

aych

em E

PP 0

612

2/00

www.tycoelectronics.com

All the above information, including illustrations is believed to be reliable. Users, however, should independently evaluate the suitability of each product for their application. Raychem makes no warranties as tothe accuracy or completeness of the information and disclaims any liability regarding its use. Raychem’s only obligations are those in the Standard Terms and Conditions of Sale for this product and in no casewill Raychem be liable for any incidental, indirect, or consequential damages arising from the sales, resale, use or misuse of the product. Raychem Specifications are subject to change without notice. In addition,Raychem reserves the right to make changes in materials or processing, without notification to the Buyer, which do not affect compliance with any applicable specification. AMP, ELCON, ELO TOUCHSYSTEMS, HTS, MACOM, MADISON, NETCONNECT, RAYCHEM, SIMEL are trademarks of Tyco International Ltd.

Tyco Electronics Raychem GmbHEnergy DivisionHaidgraben 685521 Ottobrunn/Munich GermanyTel. (089) 6089-0 Fax (089) 609 63 45

Tyco Electronics CorporationEnergy Divisionc/o AMP Singapore Pte LtdNo. 26 Ang Mo Kio Industrial Park 2Singapore 569507Tel. 65-4836012Fax 65-4836031

Tyco Electronics CorporationEnergy Division8000 Purfoy RoadFuquay-Varina, NC 27526-9349, USATel. (800) 327-6996Fax (800) 527-8350

Members of the Tyco Electronics Corporation:

•Wedge technology products •Electrical connectors •Cable accessories •Asset protection •Surge arresters •Insulators •Electrical connectors •Fittings •Associated toolings

OLIC DB UK 31.01.2000 12:53 Uhr Seite 2

http://energy.tycoelectronics.comEnergy Division

OLITOverhead line insulation tapeVoltage class 25 kVMax. conductor Ø 15 mm

Product descriptionOLIT tape is an adhesive-lined, heat-shrinkable insulating tape which hasbeen helically preformed to make iteasy to install on overhead conduc-tors.

When the tape is wrapped around the conductor and shrunk down bythe application of heat, the adhesivemelts and amalgamates the over-lapping layers of tape together thusproducing, in effect, a wraparoundtube. Although self-amalgamating,OLIT tape does not adhere to metalallowing easy removal for mainte-nance.

ApplicationsOLIT tape provides overhead lineinsulation for the prevention of faultscaused by swinging conductors andintermittent contact with tree branches,birds and animals. OLIT tape providesflashover protection up to 17.5 kV or 25 kV if a second layer of tape isapplied.

Features/benefits• Compatible with all other products in

the Raychem MV insulation enhance-ment system

• Remains flexible at low temperatures• High dielectric strength, weather and

track-resistance ensure excellent elec-trical performance

• Continuous operating temperature up to 70°C

• Suitable for indoor and outdoor use • Preformed into a spiral for easy

installation on overhead conductors• Easily and cleanly removed for

maintenance• Can be stored indefinitely at tempera-

tures up to 50°C without loss of per-formance

R

EPP0611 3/03 25.03.2003 17:37 Uhr Seite 1

© T

yco

Ele

ctro

nic

s E

PP

061

1 3

/03

Tyco Electronics Raychem GmbH, Energy DivisionFinsinger Feld 1, 85521 Ottobrunn/Munich, GermanyPhone: +49-89-6089-0, Fax: +49-89-6096345

Energy Division – a pioneer in the development of economical solutions forthe electrical power industry. Our product range includes: cable accessories, connectors & fittings, electrical equipment, instruments, lighting, insulators &insulation enhancement and surge arresters.

For more information and your country contact person, please visit us at: http://energy.tycoelectronics.com

All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable.Users, however, should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particularquality or performance. Such an assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forthin our standard terms and conditions of sale. ALR, AMP, AXICOM, B&H, BOWTHORPE EMP, CROMPTON INSTRUMENTS, DORMAN SMITH, DULMISON, GURO, HELLSTERN, LA PRAIRIE, MORLYNN, RAYCHEM, and SIMEL are trademarks.

Key product specifications Test method RequirementDielectric strength ASTM D149, IEC 243 130 kV/cm min. @ 2 mm

Accelerated ageing ISO 188, ASTM D2671 168 hrs @ 120°C- Tensile strength 10 MPa min.- Ultimate elongation 300% min.

Low temperature ASTM D2671 No crackingflexibility Procedure C after 4 hrs @ -40°C

Volume resistivity ASTM D257, IEC 93 1 x 1013 Ohm cm min.

Smoke index NES 711 Less than 50

Acid gas generation Raychem PPS 3010 4.23 Less than 3% by weight

Resistance to transformer oil VDE 0370 168 hrs @ 23°C- Tensile strength 10 MPa min.- Ultimate elongation 300% min.

Note: For further product specification information see Raychem PPS 3010/33. The above information refers to backingmaterial only, for adhesive requirements see PPS 3012/13.

Ordering information

Ordering Conductor Conductor size UOM: Conductor length description outside diameter roll of length insulated per piece

(mm) (mm2) (m) (m)OLIT-M 7 35 8 6.7

OLIT-M 9 50 8 6.2

OLIT-M 12 95 8 5.3

OLIT-M 15 150 8 4.4

Note: Maximum longitudinal change after free recovery: -30 %. Installation instructions EPP 0624 5/96 and MaterialSafety Data Sheet available on request.

Technical reports OLIT tape is preformed into a spiral using HVBT high voltage insulation tape,please refer to the following test report:

UVR 8023 – Qualification report for HVBT

Overhead line insulation tapeOLIT

EPP0611 3/03 25.03.2003 17:37 Uhr Seite 2

HVCEHigh Voltage Creepage ExtendersA remedy for pollution flashovers of insulators

R

Raysulate Creepage Extenders increase theflashover performance of insulators byreducing the surface electric stress, reduc-ing the leakage current and increasing theelectric strength of the insulators.Installation of creepage extenders:

– Increases creepage length– Improves insulator shape– Adds high performance polymeric

material to the creepage path

Pollution flashoversChanging environments can cause increasesin pollution levels which lead to excessivecontamination of high voltage insulators.This may lead to unacceptably frequent flashovers if the creepage length and general design is inadequate.

A replacement insulator having greater elec-tric strength may be installed but the costsof this are high especially when a completeassembly, like a bushing, is involved. Com-mon palliatives include live washing whichreduces the contamination level, or surfacetreatments, either grease or rubbery coat-ings which smother the dirt or make thesurface less wettable, or both. These palliatives have disadvantages in costand effectiveness. The frequency of washingcan be unacceptable and in some circum-stances washing may promote flashover.Grease is a fire risk when it becomes choked with pollution and its removal isunpleasant and expensive. Coatings are difficult to apply and are also difficult toremove when eroded.

The Raysulate Creepage Extender is a poly-meric skirt internally coated with a speciallyformulated mastic. When heated the productshrinks around and bonds onto an existinginsulator shed increasing the effective dia-meter and creepage distance of the insulator.

Creepage extender design features

Increases creepage lengthThis increases electric strength by reducingleakage current and surface stress.

Improves insulator shapeThe increased shed diameter improves strikedistance and improves heavy wetting performance by creating an umbrella effect.

Bonds to insulator surfaceThe extender adhesive has been speciallyformulated to strongly bond to the existingporcelain or glass skirt. Thus, the assembly

High Voltage Creepage ExtendersA remedy for pollution flashovers of insulators

Raysulate

needs only periodic inspection and will beeffective many times longer than grease.

RuggedExtenders are designed to be resistant toconventional spray washing techniques andwill withstand all normal handling abuseand extreme weather conditions.

Proven materialsThe extenders are fabricated usingRaychem’s unique high voltage materialstechnology which has over 25 years of highvoltage field experience in adverse environ-ments all over the world on cable termina-tions, insulators and bushings.

Creepage extenders on 66 kV insulators

Creepage extenders on 24 kV bushings

Creepage extenders on 66 kV substation in a heavily polluted marine environmentadjacent to a steelworks

General properties Test method Typical data*Density ISO/R1183 Method A 1.2 g/cm3

Tensile strength ISO 37 10 N/mm2

Ultimate elongation ISO 37 400%

Low temperature flexibility4 hours at -40°C ASTM D2671 Procedure C no cracking

Thermal endurance IEC 216 120°C

Electric strength IEC 243 140 kV/cm

Dielectric constant IEC 250 3

Volume resistivity IEC 93 1 x 1014 Ω cm

Additional properties Further details are given in Raychem Specification PPS 3011

Note: *Typical qualification test data. Minimum requirements aregiven in Raychem specification PPS 3011/1

Simple to installJust degrease the insulator and shrink theextender with a gas torch or hot air gun.Raychem can provide installation training.

Creepage extender testingData from IEC 815 shows that at a fixed voltage, our typically recommanded exten-sion of 20% to the creepage will more thandouble the pollution level needed to causeflashover (see figure 1). Pollution flashovertests (to IEC 507) on insulators fitted withcreepage extenders show that, for a fixedsalt concentration, flashover values increasein proportion to the increased creepagedistance. Figure 2 shows typical results on a 66 kV post insulator.

In practice, these results show that the ad-dition of creepage extenders can effectivelychange an insulator which has marginal per-formance in the prevailing conditions to onewhich has a large margin of safety againstpollution flashover. Tests have been done on a variety of insulator sizes and shapesincluding suspension and post insulatorscovering a range of diameters. The resultsconsistently show an improvement for allinsulators. Where the insulators are of aparticularly bad design (eg. close packedsheds of identical size) the improvement in shape adds to the effect of the longer creepage path to give exceptionally goodresults.

Raychem report UVR 8139 summarizesthese results.

Materials propertiesRaychem’s high voltage insulating materialshave undergone long-term field and labora-tory testing to determine their suitability foruse in the high voltage environment. Theuse of the material (eg. in several millionRaychem high voltage cable terminationsinstalled worldwide) bears out the excellenttesting results and has helped establish anoutstanding service record in the mostsevere environmental conditions.

Tracking and erosion resistance testingOn the ASTM D2303 inclined planetest, thematerial is non-tracking under all conditionsincluding addition of 1% sugar contaminant.

Resistance to weatheringRaychem’s on-going material tests measurethe retention of elongation as a method ofmonitoring ageing. Retention of elongationis a good measure of resistance to crackingby UV light. The material properties measu-red for the Raychem high voltage materialdemonstrate its suitability for use outdoorseven in extreme desert conditions where UVlight concentrations are severe. See reportNo. EDR 5018.

Effect of creepage distance on salt fog concentration withstand valueFigure 1

Min

imum

sal

t fog

con

cent

ratio

n (K

g/m

3 )

320

160

80

40

20

10

5

20 25 30 35 40

Four extenders per 1000 mmcreepage 80 Kg/m3 salt fog

Two extenders per 1000 mmcreepage 32 Kg/m3 salt fog

No extenders. Insulator design = 20 mm/kV14 Kg/m3 salt fog

Flashover voltage versus number of extenders on 66 kV post insulatorFigure 2

Specific creepage distance mm/phase to phase kV

60

50

45

40

35

301500 Control 1700 Plus two extenders 1900 Plus four extenders

Horizontally mounted

Vertically mounted

kV a

t fla

shov

er –

IEC

507,

80

Kg/m

3sa

lt fo

g

Total creepage (mm)

Selection tableCreepage extenders are usually fitted toinsulators with normal or alternating shedprofiles (as defined by IEC 815). This IECspecification also categorises insulators into one of four pollution classes.

Class I (ESDD* 0.03 to 0.06 mg/cm2) Light Creepage = 16 mm/kV system

Class II (ESDD 0.1 to 0.2 mg/cm2) Medium Creepage = 20 mm/kV system

Class III (ESDD 0.3 to 0.6 mg/cm2) Heavy Creepage = 25 mm/kV system

Class IV (ESDD > 0.6 mg/cm2) Very heavy Creepage = 31 mm/kV system

*ESDD equivalent salt deposit density

We recommend moving from one class to ahigher pollution class for improving flash-over performance as shown in the table.

– Creepage extenders can also be used to produce extensions on insulators designed for highly polluted areas (with > 31 mm/kV as designed).

– For specific recommendation, contactyour local Raychem representative. They can advise on fitting creepage extenders to non-standard shed profilesand pollution class insulators.

Insulator Voltage Class No. of Creepage Extenders to move toII III IV

I 1 2 **12/17.5 II – 1 2

III – – 1I 1 2 **

24 II – 1 3III – – 2I 2 3 **

36 II – 2 4III – – 2I 3 ** **

72 II – 4 **III – – 4I 5 ** **

145 II – 7 **III – – 8

**Recommend new insulator fitted

Dimensions in mm (inches) Application rangeSize Min. internal dia. Max. shed dia. Min. shed dia. Nominal creepage

of the extender of insulator of insulator extension per(as supplied) (d) (d) extender

HVCE-100/ 80-01 115 (4.5) 100 (4.0) 80 (3.2) 100 (4.0)HVCE-120/100-01 135 (5.3) 120 (4.7) 100 (4.0) 100 (4.0)HVCE-140/120-01 155 (6.1) 140 (5.5) 120 (4.7) 100 (4.0)HVCE-160/140-01 180 (7.1) 160 (6.3) 140 (5.5) 100 (4.0)HVCE-183/161-01 205 (8.1) 183 (7.2) 161 (6.3) 100 (4.0)HVCE-205/184-01 230 (9.0) 205 (8.1) 184 (7.2) 100 (4.0)HVCE-226/206-11 241 (9.5) 226 (8.9) 206 (8.1) 100 (4.0)HVCE-247/227-11 262 (10.3) 247 (9.7) 227 (8.9) 100 (4.0)HVCE-268/248-11 283 (11.1) 268 (10.5) 248 (9.8) 100 (4.0)HVCE-289/269-11 304 (12.0) 289 (11.4) 269 (10.6) 100 (4.0)HVCE-310/290-11 325 (12.8) 310 (12.2) 290 (11.4) 100 (4.0)HVCE-331/311-11 346 (13.6) 331 (13.0) 311 (12.2) 100 (4.0)HVCE-352/332-11 367 (14.4) 352 (13.8) 332 (13.1) 100 (4.0)HVCE-373/353-11 388 (15.3) 373 (14.7) 353 (13.9) 100 (4.0)HVCE-394/374-11 409 (16.1) 394 (15.5) 374 (14.7) 100 (4.0)

Ordering information1 XX denotes colour (01 = red)2 On insulators close to the maximum dia-

meter in the application range, the cree-page extender will droop when installed.For further information, see the qualifi-cation report UVR 8139.

3 The ordering unit of measure is pieces.

Non standard sizesIn many cases, creepage extenders for othersizes are available or can be designed.Contact your local Raychem representativefor details.

Ordering exampleTo order a red creepage extender for a shed of diameter 110 mm, simply order:1 piece of HVCE–120/100-01

d

© T

yco

Ele

ctro

nic

s E

PP

035

5 2

/02

http://energy.tycoelectronics.com

Tyco Electronics Raychem GmbHEnergy DivisionHaidgraben 6, 85521 Ottobrunn/Munich, GermanyPhone: ++49-89-6089-0, Fax: ++49-89-6096345

ArgentinaPhone: ++54-11-4733 2277Fax: ++54-11-4733 2267AustraliaPhone: ++61-2-4390 1111Fax: ++61-2-4353 2497BrazilPhone: ++55-11-3611 1862Fax: ++55-11-3611 2457

CanadaPhone: ++1-905-475 6222Fax: ++1-905-470-4453FrancePhone: ++33-3-80583200Fax: ++33-3-80341015MexicoPhone: ++52-5-729 0405Fax: ++52-5-361-8545

ThailandPhone: ++66-2-7394026 - 32Fax: ++66-2-3260563 - 64United States of AmericaPhone: ++1-800-327-6996Fax: ++1-800-527-8350United KingdomPhone: ++44-1772-325400Fax: ++44-1772-726276

All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct andreliable. Users, however, should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance ofany particular quality or performance. Such an assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for theseproducts is set forth in our standard terms and conditions of sale. ALR, AMP, AXICOM, B&H, Bowthorpe EMP, Critchley, Dorman Smith, Dulmison, Guro, Hellstern, La Prairie, Morlynn, Raychem, and SIMEL are trademarks.