Completion of AssemblyThe electronics are reinstalled after mounting the lower section.

Caution: During all work the light-sensitive sensor many not be touched.

To refit the cover engage the upper half using the two catches and push both halves together (there will be an audible click) and then tighten the screws.

Connect the L240 XIB Bus as follows:1 2 3 4

+ 12 V - A B

L240 ext. BUS (XIB) + - A B

Caution: For all other settings – please consult the Intrusion Alarm System L240 manual!

Installation locationThe recommended mounting height is 2.3 m. The unit can be mounted between 2.1 m and 2.5 m without adjustment, when mounted on a vertical surface. It may only be mounted on permanent, vibration-free walls. Large objects situated before the detector obstruct the detec-tion range. The detector may not be subject to direct sunlight, heat sources and strong draughts (e.g. fans of air-conditioning systems) to prevent false alarms. The installation location of both detectors must have a minimum clearance of greater than 1 m (independent of the walls and ceilings).

Preparation and mountingTo remove the cover the screw must be loosened (do not unscrew fully). Then insert a flat screwdriver into the slot underneath the screw and twist it. When the detector is opened the electronic circuit board can be unlatched via the two catches and removed simultaneously from the plug-in socket. On the lower housing section the selected cable entry points and mounting apertures can be knocked out. Please note that knock out no. 6 must be used with the off the wall anti-tamper cup. Introduce the cables, connect them and provide strain relief using the enclosed cable ties.

BUS-IR Dual Motion Detector EIM/XB and EIM/XC

1 = terminal block2 = cable entry point3 = cable attachment point for cable tie4 = cover screw (loosen only – do not remove)5 = observe cable entry6 = position of mounting screws for wall – or corner mounting.

(Use is mandatory in conjunction with the off the wall tamper cup detection)

Connection to external bus (XIB) of the EMA L240

AA

B

C

A = Knockout for corner mountingB = Knockout for wall mountingC = Knockout for mounting bracket

Standard XIBwiring

1

2

3

45

6

.

Please ensure that the cables do not hinder the function of tamper cup.

Flickers quickly Antimask calibration fault

G 110513

912

1114

G 110513

logged

been masked

been masked

Contact

Ord

er N

umbe

r 2C

DC

541

150

D02

01 p

rinte

d in

Ger

man

y (0

7/09

-1.2

-ZV

D)Note:

We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document.

We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents - in whole or in parts - is forbidden without prior written con-sent of ABB AG.