BVQ is the most sophisticated and comprehensive performance and capacity monitoring and performance analysis software in the market for IBM’s storage products IBM SAN Volume Controller (SVC), IBM Storwize V7000 and the new IBM Storwize V3700.TRANSCRIPT
![Page 1: Bvq use case storage tier analysis with bvq (ba).pptx](https://reader034.vdocument.in/reader034/viewer/2022050808/558505a4d8b42ab8128b5299/html5/thumbnails/1.jpg)
BVQ
Storage Tier Analysis
Michael Pirker [email protected] +49 151 180 25 26 0
Kunde xyz | BVQ Herz Kreislauf Analyse | 19.09.2012 | © SVA GmbH 2012 |
![Page 2: Bvq use case storage tier analysis with bvq (ba).pptx](https://reader034.vdocument.in/reader034/viewer/2022050808/558505a4d8b42ab8128b5299/html5/thumbnails/2.jpg)
Page 2
BVQ Storage Tier Analysis The BVQ Storage Tier Analysis shows very precisely where volumes are stored best in sense of performance and price
The performance capabilities of most storage setups are completely oversized
Several reasons for this • missing knowledge about real storage performance needs • missing knowledge about actual storage performance capabilities • avoid provoking an unplanned storage performance bottleneck situation
BVQ Storage Tier Analysis is a Method which uses BVQ Treemap with IO Density Metrics and BVQ IO Density Coloring and BVQ VDisk Perfromance Analysis
![Page 3: Bvq use case storage tier analysis with bvq (ba).pptx](https://reader034.vdocument.in/reader034/viewer/2022050808/558505a4d8b42ab8128b5299/html5/thumbnails/3.jpg)
Page 3
Storage Setup – Storage Types
Disk Type High End DS8000 300GB 15k R6 340IOPS/TiB
Disk Type LowEnd 114 TiB
XIV 2TB 7k R1 45 IOPS/TIB DS47 2TB 7k 21IOPS/TiB
Disk Type MidRange DS47 750GB 7k 57 IOPS/TiB
Different Storage Quality
![Page 4: Bvq use case storage tier analysis with bvq (ba).pptx](https://reader034.vdocument.in/reader034/viewer/2022050808/558505a4d8b42ab8128b5299/html5/thumbnails/4.jpg)
Page 4
Storage Setup – Storage Types
Disk Type High End DS8000 300GB 15k R6 340IOPS/TiB
Disk Type LowEnd 114 TiB
XIV 2TB 7k R1 45 IOPS/TIB DS47 2TB 7k 21IOPS/TiB
Disk Type MidRange DS47 750GB 7k 57 IOPS/TiB
Different Storage Quality
![Page 5: Bvq use case storage tier analysis with bvq (ba).pptx](https://reader034.vdocument.in/reader034/viewer/2022050808/558505a4d8b42ab8128b5299/html5/thumbnails/5.jpg)
Page 5
Storage Setup – Storage Types
Big Volume 6TiB
Small Volumes
![Page 6: Bvq use case storage tier analysis with bvq (ba).pptx](https://reader034.vdocument.in/reader034/viewer/2022050808/558505a4d8b42ab8128b5299/html5/thumbnails/6.jpg)
Page 6
Storage Setup – Performance Capabilities
DS8000 300GB 15k R6 340IOPS/TiB
DS8300 Storage Tier Raid 6, 300GB 15k Available Capacity:
82 TiB Used Capacity : 80 TiB Perf. Capability:
~27.200 IOPS (340
IOIPOS/TiB)
XIV Storage Tier 2TB Disk 7K Available Capacity:
80 TiB Used Capacity : 70 TiB Perf. Capability: ~3600 IOPS
(45 IOIPOS/TiB)
DS47 Storage Tier Raid 5, 750GB, 7K Available Capacity:
20 TiB Used Capacity : 20 TiB Perf. Capability:
~1.140 IOPS (57 IOIPOS/
TiB)
XIV 2TB 7k R1 45 IOPS/TIB DS47 2TB 7k 21IOPS/TiB
DS47 Storage Tier 2TB Disk 7K Available Capacity:
40 TiB Used Capacity : 36 TiB Perf. Capability: ~840 IOPS
(21 IOIPOS/TiB)
![Page 7: Bvq use case storage tier analysis with bvq (ba).pptx](https://reader034.vdocument.in/reader034/viewer/2022050808/558505a4d8b42ab8128b5299/html5/thumbnails/7.jpg)
Page 7
Volumes with Performance > 1000 IOPS / TiB
IOPS/TiB
.>1000
.>500
.>250
.>150
.>50
DS8000 300GB 15k R6 340IOPS/TiB
DS47 750GB 7k 57 IOPS/TiB
XIV 2TB 7k R1 45 IOPS/TIB DS47 2TB 7k 21IOPS/TiB
![Page 8: Bvq use case storage tier analysis with bvq (ba).pptx](https://reader034.vdocument.in/reader034/viewer/2022050808/558505a4d8b42ab8128b5299/html5/thumbnails/8.jpg)
Page 8
Storage Setup – Volumes with more than 1000 IOPS / TiB
IOPS/TiB
.>1000
.>500
.>250
.>150
.>50
DS8000 300GB 15k R6 340IOPS/TiB
Orange marked volumes have an IO Denisty with more than 1000 IOPS/TiB
DS47 750GB 7k 57 IOPS/TiB
XIV 2TB 7k R1 45 IOPS/TIB DS47 2TB 7k 21IOPS/TiB
![Page 9: Bvq use case storage tier analysis with bvq (ba).pptx](https://reader034.vdocument.in/reader034/viewer/2022050808/558505a4d8b42ab8128b5299/html5/thumbnails/9.jpg)
Page 9
Volumes with Performance > 500 IOPS / TiB
IOPS/TiB
.>1000
.>500
.>250
.>150
.>50
DS8000 300GB 15k R6 340IOPS/TiB
DS47 750GB 7k 57 IOPS/TiB
XIV 2TB 7k R1 45 IOPS/TIB DS47 2TB 7k 21IOPS/TiB
![Page 10: Bvq use case storage tier analysis with bvq (ba).pptx](https://reader034.vdocument.in/reader034/viewer/2022050808/558505a4d8b42ab8128b5299/html5/thumbnails/10.jpg)
Page 10
Volumes with Performance > 250 IOPS / TiB
IOPS/TiB
.>1000
.>500
.>250
.>150
.>50
DS8000 300GB 15k R6 340IOPS/TiB
DS47 750GB 7k 57 IOPS/TiB
XIV 2TB 7k R1 45 IOPS/TIB DS47 2TB 7k 21IOPS/TiB
![Page 11: Bvq use case storage tier analysis with bvq (ba).pptx](https://reader034.vdocument.in/reader034/viewer/2022050808/558505a4d8b42ab8128b5299/html5/thumbnails/11.jpg)
Page 11
Volumes with Performance > 150 IOPS / TiB
IOPS/TiB
.>1000
.>500
.>250
.>150
.>50
DS8000 300GB 15k R6 340IOPS/TiB
DS47 750GB 7k 57 IOPS/TiB
XIV 2TB 7k R1 45 IOPS/TIB DS47 2TB 7k 21IOPS/TiB
All green Volumes are under 150 IOPS typically midrange 10k classmight be 10k 600GB Raid 5
![Page 12: Bvq use case storage tier analysis with bvq (ba).pptx](https://reader034.vdocument.in/reader034/viewer/2022050808/558505a4d8b42ab8128b5299/html5/thumbnails/12.jpg)
Page 12
Volumes with Performance > 50 IOPS / TiB
IOPS/TiB
.>1000
.>500
.>250
.>150
.>50
DS8000 300GB 15k R6 340IOPS/TiB
DS47 750GB 7k 57 IOPS/TiB
XIV 2TB 7k R1 45 IOPS/TIB DS47 2TB 7k 21IOPS/TiB
All green Volumes are under 50 IOPS typically SATA class60% of DS8300 ~50TB >80% of DS47 Speicher. ~18TB
![Page 13: Bvq use case storage tier analysis with bvq (ba).pptx](https://reader034.vdocument.in/reader034/viewer/2022050808/558505a4d8b42ab8128b5299/html5/thumbnails/13.jpg)
Page 13
BVQ Heatmap – IO Density Coloring One Mouseclick Analysis
The BVQ Heatmap performs the same kind of analysis on one click Blue color means that this volume needs less than 20% of the performance capabilities of the group. It is a candidate for migration to cheaper storage. Normally we verify this in a more detailed performance analysis which can be done in some minutes per volume. The cost saving can be more than $2000 per TB depending storage quality On this table you see the other color coding's
![Page 14: Bvq use case storage tier analysis with bvq (ba).pptx](https://reader034.vdocument.in/reader034/viewer/2022050808/558505a4d8b42ab8128b5299/html5/thumbnails/14.jpg)
Page 14
BVQ Heatmap – what to do with it …
Migrate Volumes and free up Storage class
New Nearline
Storage Class
Migrate Volumes and free up Storage class
Migrate Volumes and free up Storage class
Avoid Bottlenecks Move high perf. Volumes
To high perf. Storage
Allows fast and sound decisions where to place your volumes
![Page 15: Bvq use case storage tier analysis with bvq (ba).pptx](https://reader034.vdocument.in/reader034/viewer/2022050808/558505a4d8b42ab8128b5299/html5/thumbnails/15.jpg)
Page 15
BVQ Performance Analysis to verify … • Verify Volume before migration – one right mouse button click on Volume away
Cache % DR above Cache DR below Cache (Controller)
IOPS and response times
Datarates above and below SVC cache and cache %
![Page 16: Bvq use case storage tier analysis with bvq (ba).pptx](https://reader034.vdocument.in/reader034/viewer/2022050808/558505a4d8b42ab8128b5299/html5/thumbnails/16.jpg)
Page 16
Web Pages German
• BVQ Webseite mit Kundenreferenzen und Seite für BVQ Vertriebspartner
http:www//bvq-software.de/
• BVQ Videos auf dem YouTube SVA Kanal http://www.youtube.com/user/SVAGmbH http://tinyurl.com/bvqvid
• BVQ Webseite von SVA GmbH http://www.sva.de/sva_prod_bvq.php
English
• Developer Works BVQ Community Blog https://www.ibm.com/developerworks/mydeveloperworks/blogs/BVQ/?lang=en http://tinyurl.com/bvqblog
• Developer Works Documents and Presentations https://www.ibm.com/developerworks/mydeveloperworks/files/app?lang=en#/collection/4e10257c-a765-4b3b-9dc1-17f0cebb6d47 http://tinyurl.com/bvqdoc
![Page 17: Bvq use case storage tier analysis with bvq (ba).pptx](https://reader034.vdocument.in/reader034/viewer/2022050808/558505a4d8b42ab8128b5299/html5/thumbnails/17.jpg)
Page 17
If you are interested in BVQ or an Performance Analysis with BVQ then please contact
BVQ is a product from SVA System Vertrieb Alexander GmbH