Amager Strandvej 124 2300 Copenhagen Denmark Tel. +45 3286 0525 Fax: +45 3258 1330 e-mail: [email protected] www.unielec.dk BW-700 Manual English 2010-1 Page 1 of 14 Bridge Watch Alarm System BW-700 Manual BW-700 is produced in accordance with international and Danish laws for ”one man bridge” operation e.g. IMO resolution A.830. BW-700 has been designed for mounting on a DIN rail in the power cabinet or flush mounting. The purpose of the bridge watch alarm system is to ensure the continuous monitoring of the bridge operator’s fitness during "one man bridge" operation.

Upload: -

Post on 13-Apr-2015

29 views

Category:

Documents


4 download

DESCRIPTION

Bridge watch alarm system

TRANSCRIPT

Page 1: BW-700 Manual English 2010-1

Amager Strandvej 1242300 Copenhagen

DenmarkTel. +45 3286 0525

Fax: +45 3258 1330e-mail: [email protected]

www.unielec.dk

BW-700 Manual English 2010-1 Page 1 of 14

Bridge Watch Alarm System BW-700 Manual

BW-700 is produced in accordance with international and Danish laws for ”one man bridge” operation e.g. IMO resolution A.830.

BW-700 has been designed for mounting on a DIN rail in the power cabinet or flush mounting.

The purpose of the bridge watch alarm system is to ensure the

continuous monitoring of the bridge operator’s fitness during "one man bridge" operation.

Page 2: BW-700 Manual English 2010-1

Amager Strandvej 1242300 Copenhagen

DenmarkTel. +45 3286 0525

Fax: +45 3258 1330e-mail: [email protected]

www.unielec.dk

BW-700 Manual English 2010-1 Page 2 of 14

Technical specifications:

Main supply: 12 or 24 V

12 V ( Min. 11V / Max. 15V ) 24 volt ( Min. 16V / Max. 29V )

Power consumption: Max. 0,4 A. The power supply must be secured

against overcurrent externally. Max. 2.0 A Power failure alarm: Mount a suitable relay and connect to General alarm. Se wiring diagram page 6. Consumption: Max. 10.0 Watt Dimensions: Width 105 mm / Height 86 mm / Depth 58 mm. Operating Temperature: -10 up to +65 degrees C. Adjustable timers: Qty.: 2 pcs.

Timer 1: adjustable from 3 up to 12 minutes. Timer 2: adjustable from 60 up to 180 sec. (internal)

Relay contacts: Qty.: 4 pcs.

All relay contacts are galvanic separated from the BW-700 unit and from each other.

Relay contacts: Max. 250V AC, 5A. Protection: IP54. Operation: Key disconnector: 3 positions. The key can be taken

out in all positions. Dimmer function: Adjustment of the light intensity from max. to –80%. Adjustment of both internal and external light. Supply to external light: 12V Max. 200mA. 12 V output: To movement detectors. Max 200 mA. Cable requirements: Marine proof cable min. 0,5mm² and maximum 1mm².

Page 3: BW-700 Manual English 2010-1

Amager Strandvej 1242300 Copenhagen

DenmarkTel. +45 3286 0525

Fax: +45 3258 1330e-mail: [email protected]

www.unielec.dk

BW-700 Manual English 2010-1 Page 3 of 14

Cable connections:

Terminal 1: Plus 24 V supply Terminal 2: Minus ( GND ) Terminal 3: Plus 12 V supply Terminal 4: Minus ( GND ) Terminal 5: Plus 12 V max. 200mA. To movement detector Disconnects in case of overload. Terminal 6: Reset in. Terminal 4-6 closed by resetting the timer. Terminal 7: Emergency button. Terminal 4-7 must be closed for 2 sec. to activate the emergency function. Terminal 8: Plus 12 V max. 200mA To background light, is adjusted by the DIMMER button Terminal 9: Minus ( GND ) Terminal 10: Supply to auto pilot. When active terminal 9-10 must be closed. Terminal 11 – 12: Relay contact. Togler 5 sec. before timer has ran out Terminal 13 – 14: Relay contact. Closed by alarm 1. Terminal 15 – 16: Relay contact. Closed by alarm 2. Terminal 17 – 18: Relay contact. Closed by alarm 3.

Page 4: BW-700 Manual English 2010-1

Amager Strandvej 1242300 Copenhagen

DenmarkTel. +45 3286 0525

Fax: +45 3258 1330e-mail: [email protected]

www.unielec.dk

BW-700 Manual English 2010-1 Page 4 of 14

Operating instructions: The Bridge Watch can only be activated and deactivated by use of a key. Therefore, only authorised personnel (usually the captain) can decide if the bridge watch alarm should be active or not. The key function has 3 setting modes: The 3 modes are: ON (the BW is active all the time), Off (the BW is not active) and Auto (in this mode the BW is only active when the ship’s autopilot is on). When the BW-700 is active, the built-in timer must be reset, before the preset timer has run out. The reset of the timer can be done in two different ways: manually by activating a reset button or by ensuring a constant movement (activity) sensed by the movement detector on the bridge. The time is set on the adjusting button Timer before the BW is activated. The preset time cannot be changed as long as the BW-700 is active. When the timer is 15 sec. from running out, a warning is activated. The warning can be a small alarm buzzer or a light signal depending on what is connected. This gives the captain time to reset the timer before the alarm is activated. If the captain of the ship has not reset the timer within 15 seconds the 1st of the 3 alarms will be activated. Alarm 1: This alarm is placed on the bridge and is meant to ensure a weakening of e.g. a drowsy ships master. The alarm can be switched off by resetting the timer. If the timer is not reset after 15 seconds the alarm switches to alarm 2. Both alarm 1 and 2 is now active. Alarm 2: This alarm is placed where the back-up officer / captain is presumed to be. Now the alarm can only be switched off by using a key. However, the alarm on the bridge will be silent when the timer is reset. Alarm 2 stays active until the key is used to switch it off. If the alarm is not switched off and there is still no activity on the bridge after 60-180 seconds the alarm 3, now alarm 1, 2 and 3 is activated. The timer can be set from 60-180 seconds during installation, to give time to the back-up officer to react on the alarm. Alarm 3: This alarm is placed in the crew area. The alarm can only be switched off by using a key. However, the alarm on the bridge becomes silent when the timer is reset in order to avoid stressed personnel. Alarm 2 and 3 remains active until the key is used to switch it off. Emergency calls: BW-700 also has an option for connection of emergency calls. This will be in the form of a push button. When activated for 2 seconds the alarm will automatically go to alarm 2 and subsequently to alarm 3 if no action is taken. Using this function the ships master is able to call for assistance if needed. The alarm can only be switched off by using a key. However, the alarm on the bridge becomes silent when the timer is reset in order to avoid stressed personnel. Alarm 2 and 3 remains active until the key is used to switch it off.

Page 5: BW-700 Manual English 2010-1

Amager Strandvej 1242300 Copenhagen

DenmarkTel. +45 3286 0525

Fax: +45 3258 1330e-mail: [email protected]

www.unielec.dk

BW-700 Manual English 2010-1 Page 5 of 14

Relay

Relay

Relay

Relay

Timer4

Timer3

Timer2

Int. Adjust.1-3 min.

Dimmer20-100%

Aut

opilo

tde

tect

or

Timer1

Ext. Adjust.3-15 min.

Ext. just.

Poweradjust.

24 >12volt reg.

Em

erge

ncy

dete

ctor

Key

AutoOn

Plus 24 V input

Minus ( GND ) input

Plus 12 V input

Minus ( GND ) output

Minus ( GND ) output

Plus 12 Vmovement detector

Reset input

Emergency input

Plus 2-12 V outputto background light

Auto pilot signal input

Alarm for timer

Alarm 1output

Alarm 2output

Alarm 3output

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

PRINCIPLE DIAGRAM BW-700 CE

Page 6: BW-700 Manual English 2010-1

Amager Strandvej 1242300 Copenhagen

DenmarkTel. +45 3286 0525

Fax: +45 3258 1330e-mail: [email protected]

www.unielec.dk

BW-700 Manual English 2010-1 Page 6 of 14

Ala

rm 1

: Br

idge

.Ac

tivat

ed w

hen

the

timer

has

ran

out.

Ala

rm 2

:C

apta

in´s

qua

rters

.Ac

tivat

ed15

sec

. afte

rth

e 1s

t. al

arm

.

Ala

rm 3

:G

ener

al a

larm

- cr

ew a

rea.

Activ

ated

60-

180

sec.

afte

r the

2nd

. ala

rm.

WIR

ING

DIA

GR

AM

B

W-7

00

Fuse

2Am

p

On

Off

Aut

o

24 V

.12

V.

Ass

ista

nce

to b

ridge

Ass

ista

nce

to b

ridge

Ass

ista

nce

to b

ridge

BW

-700

AB

-2

AB

-2

AB

-2

RB

-1R

NA

RB

-1R

Whe

n ac

tive,

the

cont

act

is c

lose

d

Pow

er fa

liure

ala

rmre

lay

NO

(Not

sta

ndar

d su

pply

).

Gen

eral

ala

rm,

visu

al a

larm

or

audi

o al

arm

.

(Item

: 702

)

(Item

: 702

)

(Item

: 702

)

(Item

: 703

)

(Item

: 704

)

(Item

: 703

)

Page 7: BW-700 Manual English 2010-1

Amager Strandvej 1242300 Copenhagen

DenmarkTel. +45 3286 0525

Fax: +45 3258 1330e-mail: [email protected]

www.unielec.dk

BW-700 Manual English 2010-1 Page 7 of 14

110 mm.

On Off Auto

125 mm.

125 mm. 135 mm.

115 mm.

Page 8: BW-700 Manual English 2010-1

Amager Strandvej 1242300 Copenhagen

DenmarkTel. +45 3286 0525

Fax: +45 3258 1330e-mail: [email protected]

www.unielec.dk

BW-700 Manual English 2010-1 Page 8 of 14

The picture below shows the BW-700 mounted in a mounting box no. 710. Dimensions: Height = 185 mm. Width = 145 mm. Depth = 85 mm.

Page 9: BW-700 Manual English 2010-1

Amager Strandvej 1242300 Copenhagen

DenmarkTel. +45 3286 0525

Fax: +45 3258 1330e-mail: [email protected]

www.unielec.dk

BW-700 Manual English 2010-1 Page 9 of 14

H - 0H - HL - 0L - LH - L

H= high toneL=low tone0= no tone

AB-2 is designed for use together with BW-700. AB-2 will sound an alarm when the timer has expired. It sounds a powerfull tone from the 4 loudspeakers and the redwarnings light flashes. AB-2 can be preset to 5 different warning pitches during the installation. To avoid disturbance when the alarm goes off, AB-2 is constructed tostart with low volume, and rising to high volume within seconds. The maximumvolume can be set between 75 and 90 DB.

1 2

Voltage:Power compsumption:C :Dimensions:Temerature range:Protection:

Terminal 1:Terminal 2:

ompsumption

12 to 24 volt DC. internal. stab. to 12 volt.Max 0,15 Amp.Max 3,6 Watt.W:50mm H:75mm D:30mm-10 to +55 degrees.IP 54.

GroundAlarm plus.

AB-2:

Sound switchVolume

Assistanceto bridge

Principle diagram

Page 10: BW-700 Manual English 2010-1

Amager Strandvej 1242300 Copenhagen

DenmarkTel. +45 3286 0525

Fax: +45 3258 1330e-mail: [email protected]

www.unielec.dk

BW-700 Manual English 2010-1 Page 10 of 14

1 2 3 4

RB-1R:RB-1RNA is designed for use together with BW-700 as reset button with light warning.The unit has background light and this is regulated by the dimmer function on BW-700.5 seconds before the timer has ran out, the alarm and the background light starts flashing.

Mains supply:

Power consumption:Consumption:Dimensions:Temperature range:Protection:

Terminal 1:Terminal 2:Terminal 3:Terminal 4:

2-12 volt DC for background light12 to 24 volt DC. For warning light.Max 0,04 Amp.Max 1,0 Watt.W:50mm H:50mm D:30mm-10 to +55 degrees.IP 54.

Background light ( plus )Minus ( GND )Reset contactWarning light ( plus )

Principle diagram

Page 11: BW-700 Manual English 2010-1

Amager Strandvej 1242300 Copenhagen

DenmarkTel. +45 3286 0525

Fax: +45 3258 1330e-mail: [email protected]

www.unielec.dk

BW-700 Manual English 2010-1 Page 11 of 14

1 2 3

RB-1RNA:RB-1RNA

The unit has backgroundlight and this is regulated by the dimmer function on BW-700. 5 seconds before the timer has ran out, the alarm and the background light starts flashing.To activate the emergency function press the reset button for more than 2 seconds. After 2 seconds the sound warning will sound shortly to notify that the emergencyfunction is activated.

is designed for use together with BW-700 as reset button with sound and light warning. RB-1RNA also has an emergency function.

Mains supply:

Power consumption:C :Dimensions:Temperature range:Protection:

Terminal 1:Terminal 2:Terminal 3:Terminal 4:Terminal 5:

onsumption

2-12 volt DC for background light12 to 24 volt DC. For warning light.Max 0,04 Amp.Max 1,0 Watt.W:50mm H:50mm D:30mm-10 to +55 degrees.IP 54.

B ( plus )Minus ( GND )Reset contactEmergency contactWarning light ( plus )

ackground light

4 5Principle diagram

Page 12: BW-700 Manual English 2010-1

Amager Strandvej 1242300 Copenhagen

DenmarkTel. +45 3286 0525

Fax: +45 3258 1330e-mail: [email protected]

www.unielec.dk

BW-700 Manual English 2010-1 Page 12 of 14

Motion sensor 1. FEATURES

Input Voltage: 9 to 16 VDC Current Drain: About 28 mA @ 12 VDC Size (H x W x D): 117 x 65 x 47 mm. Weight: 109 g (3.85 oz) w/o bracket, 124 g (4.4 oz) with bracket. PIR SECTION Detector: Low noise dual-element pyroelectric sensor Tripping Indication: LED flashes green for up to 5 seconds Motion Event Verification Counter: Selectable, 1 or 2 events No. of Beams: 36 in two layers (curtain beams in bottom layer) Max. Coverage: 12 x 12 m (40 x 40 ft) / 90° field of view Vertical Adjustment: FAR and NEAR, by sliding the circuit board along a two-position scale. MW SECTION Oscillator: Microstrip DRO-stabilized Doppler module Frequency: 10.525 GHz (U.S.A. only) or 2.45 GHz (Europe) Detection Range: Adjustable from 25% to 100% (3 m to 12 m) Tripping Indication: LED glows green for up to 5 seconds Alarm Indication: LED glows red for 1.3 to 5 seconds if both detectors trip

MOUNTING Height: Up to 3.6 m (12 ft) Room Size: 8 -12 m (24 - 40 ft) in the “FAR” position; 2 - 8 m (6 - 24 ft) in the NEAR position. Bracket Adjustment: 20° downward, 20° left and right. Installation Options: Surface or corner (without bracket); surface or ceiling (with bracket) ENVIRONMENTAL RFI Protection: >30 V/m up to 1000 MHz. Operating Temperatures: -10°C to 50°C (14°F to 122°F). Storage Temperatures: -20°C to 60°C (-4°F to 140°F).

Mounting with Swivel Bracket A. Remove the front cover. B. Remove the PCB and put it temporarily aside. C. Punch out the large knockout in the round bulge at the top part of the base.

Page 13: BW-700 Manual English 2010-1

Amager Strandvej 1242300 Copenhagen

DenmarkTel. +45 3286 0525

Fax: +45 3258 1330e-mail: [email protected]

www.unielec.dk

BW-700 Manual English 2010-1 Page 13 of 14

Prevent direct sunlight from reaching the

detector

Keep wiring away from electrical power cables

Do not install behind partitions

Visual Indications The dual color LED is used to signal various alarm and trouble messages as shown in Table 1 below: Table 1. Interpreting the Visual Indications Visual Indication Significance None No detection Steady green (5 s) MW walk-test detection Flashing green PIR walk-test detection Steady red (5 s) Alarm: MW + PIR detection Flashing red and - Trouble or masking is being detected by the self test circuitry green (alternately) - Initial warm-up routine (stops 60 seconds after power up). Notes: During walk testing, the green light glows steadily (MW detection) or flashes (PIR detection),

depending on which one of the two detectors discovered the movement first. Upon subsequent discovery of the movement by the other detector, the green light goes off and the red light glows (alarm).

If the LED maintains alternate red and green flashing beyond the warm-up period, a malfunction or masking has been diagnosed. Replace the unit without delay. The DIP switch mode selector is mounted on the unit’s PC board (see Figure 5). It controls four functions as demons- trated in Figure 12 and as detailed in Table 2.

Installation hints:

Do not aim at heat sources

Mount on solid, stable surfaces

Do not expose to air drafts

Do not install outdoors

Page 14: BW-700 Manual English 2010-1

Amager Strandvej 1242300 Copenhagen

DenmarkTel. +45 3286 0525

Fax: +45 3258 1330e-mail: [email protected]

www.unielec.dk

BW-700 Manual English 2010-1 Page 14 of 14

Troubleshooting guide: Step: Problem: Description: Possible Causes:

1 No reset from motion sensor.

Check voltage on Reset 1 input (BW-700 connector pin 6). Low voltage when LED in motion sensor is red. If constant low, remove the wire to the motion sensor and check again.

Standard mounting bracket not used and screws behind the PCB is shortcutting the sensor. Remove the screws and use the standard mounting bracket.

2 No lights in BW-700

Check external fuses Check DC power on terminal 1-4 (12/24Vdc) Check the cable connections

BW-700 has no power

3 No alarm on bridge and Alarm LED 2 and 3 are always on

Check DC power on terminal 6 on BW-700 (0V/low, only when reset button is pushed or a movement is detected) Movement detector: When the red LED is on, a low pulse is sent from terminal “R” If constantly low:

1) Turn the BW-700 off (key in position off)

2) Remove all wires from terminal 6 3) Set the alarm to 3 minutes and set

the key in position on 4) Check that “alarm 1” starts after 3

minutes (BW-700 is then ok) 5) Turn the BW-700 off 6) Mount the wire from one reset

button to terminal 6 7) Set the key in position on 8) Check that “alarm 1” starts after 3

minutes 9) Check that you can reset the alarm

by pushing the reset button (reset button 1 is ok)

10) Turn the BW-700 off 11) Mount the wire from one movement

detector to terminal 6 12) Set the key in position on and don’t

move 13) Check that “alarm 1” starts after 3

minutes 14) Check that you can reset the alarm

by walking around (movement detector is ok)

15) Check additional reset buttons and movement detectors by the same procedure as above

Installation failure Movement detectors defective Reset button defective

4 No alarm 1-3 and the LED’s for alarm 1-3 are on

Check the cable connections. Check 12Vdc power at the terminals on the alarm units.

Cable failure Alarm units defective