by t r ganesh
TRANSCRIPT
WHY REMC?
• Ambitious plan by Govt of India for 175 GW RE.
• Recognise that RE is a different ball game• Must run
• Flexi watts, Reserves, Balancing etc
• Forecasting and Scheduling
• Interface with existing SCADA and
security tools
• Interface with existing scheduling suite
• Skill set requirement
Large Scale Integration of Renewables
Forecasting (Demand/ RE generation & Scheduling)
Flexi Watts - Thermal [Technical Minimum, Reserve Shut down] Inter-state Co-operation to
optimize resources
Spinning ReservesFrequency Control
(Primary/Secondary/ Tertiary)Pumped Hydro & Flexible Load
Managing Deviations Optimally Approach ERCs for regulatory Electricity Market Measures - PX
to be RTC
6
Bidding Procedure
• Tender-9091: Establishment of Renewable Energy Management Centre at Southern Region (Tamil Nadu, Andhra Pradesh, Karnataka and SRLDC)
• Two Stage Bidding Procedure
• Domestic Competitive Bidding
• e-procurement procedure: https://www.tcil-india-electronictender.com
• Date Of Issuance Of IFB : 26.08.2016
• Pre-Bid meeting : 09.09.2016
• First Stage Bids Uploading before: 26.09.2016
• First Envelope i.e. Techno -Commercial Part shall be opened on 28.09.2016
• No Bid Security is required to be accompanied with the First Stage Bids.
Establishment of Renewable Energy Management Centre at Southern
Region (Tamil Nadu, Andhra Pradesh, Karnataka and SRLDC)
Owners,Consultant
• Owners of the Project : TN SLDC, APSLDC, SLDC KPTCL, SRLDC For respective package
• Consultant : POWERGRID and Project shall be handed over to respective SLDCs and SRLDC upon completion.
• Funding for the project shall be from Ministry of Power Gross Budgetary Support (GBS) allocation.
• For the purpose of all procurement activities related to the said project POWERGRID shall be referred to as ‘Employer’.
• Payments shall be made by POWERGRID. However, POWERGRID intends to use fund to be provided by Ministry of Power through Gross Budgetary Support for eligible payments under the contracts for subject package.
Functional Scope of REMCs
• Setting up of SCADA, Forecasting Tool & Scheduling Tool systems
• Integration of existing and New RTUs/DCPC/AMR to collect data from pooling stations.
• Integration of REMC with existing main & backup xLDC SCADA System
• Data exchange with Forecasting and Scheduling tools & FSP interface
• Providing RE information to its concerned xLDC for dispatching and balancing RE power
Renewable Energy Management Centres
Status of Implementation• 11 Nos. REMC
• State level (7 Nos.): Tamil Nadu, AP, Karnataka, Gujarat, Maharashtra, MP & Rajasthan
• National/Regional level (4 Nos.): SRLDC, WRLDC, NRLDC and NLDC
• Implementation under progress
Co-located with respective Load Despatch Centres
• State, Regional and National level
• Forecasting , Real time tracking of generation from RE sources
• Advanced decision-making and control systems
• Single source information repository and coordination point for RE
Different skill sets for personnel manning REMCs and LDCs
11
Conceptual architecture of REMC
ICCP
Forecasting
Tool
RE
Scheduling
Application
Current
Scheduling
Application
FSP #1
FSP #2
FSP #n
Weather Forecast Data
REMC
SCADA
(x)LDC
SCADA
+ EMC
Real Time RE Generation
RTU
RE
Develope
rRE Schedule
Backup
control centreICCP
Real Time Data from field
•Acquire data from RTUs•IEC-101, IEC-104
•Interface with controlcenter on ICCP
•High availability, based onfully redundant hot standbyconfiguration.
•Ability to integrate withforecast tool.
SCHEMATIC OF FORECASTING TOOL
FSP : previous experience in providing Renewable (Wind/Solar) Power forecasting servicesfor at least 2000 MW of Wind or Solar generation or both combined for atleast one year ofcontinuous service in past seven (7) years as on originally scheduled date of first stagebid opening for any Transmission system operator/ Independent system operator/ RE(Wind/Solar) developer or Generator
• Day ahead/Intra Day/Weekahead power forecast
• Forecast for• aggregated at
state/region level
• Pooling station level
• Interface with multipleparties Forecasting serviceprovider (FSP) system
• Internal Forecast module
• Interface with Schedulingtool
Day ahead Scheduling and dispatch
RE-scheduling of day-ahead schedule on intra-day basis
Interface with RE generator
Configuration Diagram
SRLDC Appendix-K
Data Acquisition LAN
WAN
Router
for RTU
IEC 101/104RTUs
Application Servers(2)123456
789 `
SCADA LAN
Video
Projecti
on
GPS
ICCP Servers (2)
ICCP
LAN
LAN switch for
ICCP LAN (2)
Development
Workstation (2)
Program
Development
System
LAN switch for
PDS (2)
PDS
LAN
NMS Server
(2)
Historian &
NMS VLAN
SAN
Box (1)SAN
Box (1)
SCADA server(2)
Server
management
console
Management LAN
Data Replica
server (2)
Identity
Server (2)Centralized
management
console
EXTER
NAL
DMZ
Web Servers
(2)
Corporat
e LAN
Printer
(2)
SCADA Work
station (4)
LAN switch for Data
acquisition (2)
LAN switch for
SCADA (2)
LAN
switch
for
Interna
l DMZ
LAN
(2)
LAN
switch
for
Extern
al
DMZ
LAN
(2)
Historian
server(2)
Forecasting/S
cheduling
repository (2)
WAN
Router
for ICCP
ICCP for RLDC (main &
backup)/SLDC/NLDC
Printer
(2)
SAN
Management
Server & SAN
Switch &
Storage (2)
CFE Server (2)
S.No
ServicesQuant
ity
1 Installation, testing & Commissioning
Integration with new/existing
Control Centres on ICCP
15
Integration of existing/new
RTUs with REMC SCADA
250
Integration with Offline
application
5
2 Annual Maintenance Contract
Warranty Period 1 year
Annual maintenance contract
after expiry of Warranty
Period
6 year
3 FSP services3 nos. of FSP 2
years
2 nos. of FSP 2 years
4 Weather Services for
internal forecasting
tool
4
years
• CYBER SECURITY• DATA SECURITY• ACCESS BASED RIGHTS
DATA FROM RTU• DEMAND SCAN• PERIODIC SCAN
Critical & Non Critical functions
Critical functions:a) All SCADA functions
b) Forecasting & Scheduling functions
c) Historian
d) User Interface Requirements
e) Network Management system
f) Web Applications
Non-Critical functions:a) Database modification and generation.
b) Display modification and generation.
c) Report modification and creation.
d) Software configuration and system generation.
SCADA
FUNCTIONS
SOE
SUPERVISORY CONTROL
NMS
DATA AQUISTIONHISTORIAN
REPORTINGDASHBOARDS
ALARMSUSER
INTERFACE
Data Exchange AND DATA PROCESSING
• Data Exchange with Control Centres
• Data Exchange with Forecasting Application
• Data Exchange with RE Scheduling Application
• Data Exchange with Weather data service
• Data Exchange with RE Developers
• Data Exchange with Historian system
• Data Exchange with Offline Systems & Third-party applications
• Analog Data Processing
• Digital status Input Data processing
• Calculated Data processing • MVA Calculation
• MW and MVAR Integration
• Rate of Change
• Average Value Calculations
• Max and Min Value Calculations
• Unscheduled Interchange (UI) Charge
• Quality Codes
• Real-time data storage and playback
• Redundant data Source processing
Other Features
• Dynamic Data Presentation
• Element high lighting
• Display Types• Power System Network Display• Sub Station Single Line Diagram (SLD) Display Menu• Sub Station SLD Displays• Sub Station Tabular Displays• Alarm/Event Summary Displays• Operating Information Summaries• Computer system Configuration and Monitoring Displays• Communication Network display• Voltage Profile Display• Log Sheets Displays