c frame mkiv - series circuit breakers · 2017. 6. 5. · c frame mkiv - series circuit breakers...

29
low voltage CMKIV-SERIES-CAT OCT 2016 Catalogue Page 1 of 29 C Frame MKIV - Series Circuit Breakers The C Frame is the most traditional distribution and equipment protection circuit breaker and is available in 1 to 4 poles. This front mounted circuit breaker is available for panel mounting, and is available with a toggle handle and rocker handle. The C Frame MKIV circuit breaker is used in power distribution units, lighting control and in other equipment. Approvals The C frame MKIV is CE certified and carries various approvals such as VDE , cURus, CSA, EAC and CCC. It is also recognised to UL 1077, UL 1500 and UL 508, and listed to UL 489 and UL 489A. S A005438 AC and DC circuit breaker Hydraulic-magnetic technology 100% rating capability independent of ambient temperature Up to four poles VDE, EAC and CCC approved, CE certified UL compliant (listed / recognised) Ratings 0.1 to 50 A (specific certifications) Precision tripping characteristics Wide range of circuits, mountings, terminations and time delays Two colour handle indication (two tone flush rocker) Optional mid-trip indication (standard handle) Optional auxiliary switch and trip alarm Features Applications Telecom DC Power distribution UPS equipment Mobile power generation equipment Alternative energy equipment Lighting control Marine protection

Upload: others

Post on 28-Jan-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

  • low voltage

    CMKIV-SERIES-CATOCT 2016

    CataloguePage 1 of 29

    C Frame MKIV - Series Circuit Breakers

    The C Frame is the most traditional distribution and equipment protection circuit breaker and is available in 1 to 4 poles. This front mounted circuit breaker is available for panel mounting, and is available with a toggle handle and rocker handle.

    The C Frame MKIV circuit breaker is used in power distribution units, lighting control and in other equipment.

    Approvals

    The C frame MKIV is CE certified and carries various approvals such as VDE , cURus, CSA, EAC and CCC. It is also recognised to UL 1077, UL 1500 and UL 508, and listed to UL 489 and UL 489A.

    S

    A005438

    • AC and DC circuit breaker• Hydraulic-magnetic technology• 100% rating capability independent of ambient temperature • Up to four poles• VDE, EAC and CCC approved, CE certified• UL compliant (listed / recognised)• Ratings 0.1 to 50 A (specific certifications)• Precision tripping characteristics• Wide range of circuits, mountings, terminations and time

    delays• Two colour handle indication (two tone flush rocker)• Optional mid-trip indication (standard handle)• Optional auxiliary switch and trip alarm

    Features Applications• Telecom DC Power distribution• UPS equipment• Mobile power generation equipment• Alternative energy equipment• Lighting control• Marine protection

  • CMKIV-SERIES-CATOCT 2016

    CataloguePage 2 of 29

    low voltage

    C Frame MKIV - Series Circuit Breakers

    Technical Data

    Product Type C Frame MKIVOperating Temperature Range -40 °C to +85 °C

    Endurance 10000 operations - 1500 electrical at rated current and voltage (IEC 60934)6000 electrical operations (UL 1077)

    Dielectric Strength 1000 - 2000 V, 50 Hz for one minute after testing (IEC 60934)Weight 70 g per pole (unpacked)Humidity 35 to 85% relative humidity

    Altitude Certification tests done at altitude ≈ 2000 metres. Will operate at higher altitudes.Shock 100 G to MIL-STD-202G, test method 213B, test condition 1Vibration 10 G to MIL-STD-202G test method 204D, test condition AFlammability I2 - No ignition at 850 °C with an oxygen index of ≥ 32Toxicity F1 - Smoke index of ≤ 20 which determines the fume class

    Pollution Degree PD2 - Normally only non-conductive pollution occurs. Temporary conductivity caused by condensation is to be expected.

    Product Type Circuit Breaker Circuit Breaker Circuit BreakerApprovals UL 489 / CSA UL 489A UL 1077 / CSANumber of Poles 1, 2 1, 2 1 - 4Maximum Voltages 120 / 240 V AC 80 V DC 240 V AC, 277 V AC, 80 V DC

    Current Ratings 0.05 - 20 A 0.05 - 50 A 0.05 - 50 A, 0.1 - 30 A,0.05 - 50 A DCInterrupting Capacity 5 kA 5 kA 2 kA (AC), 7.5 kA (DC)

    Product Type Circuit Breaker Circuit Breaker SwitchApprovals IEC / EN 60934, VDE, CE, CCC UL 1500 UL 508Number of Poles 1 - 4 1, 2 1 - 4Maximum Voltages 240 / 415 V AC, 80 V DC 120 / 240 V AC, 65 V DC 240 V AC, 277 V AC, 80 V DC

    Current Ratings 0.05 - 50 A / 0.1 - 30 A, 0.05 - 50 A DC

    0.05 - 50 A 50 A

    Interrupting Capacity 2 kA (AC), 4 kA (DC) 1.5 kA -

  • low voltage

    CMKIV-SERIES-CATOCT 2016

    CataloguePage 3 of 29

    C Frame MKIV - Series Circuit Breakers

    Group 1: Frame

    Code Description Comments

    C C-Frame

    Group 2: Type

    Code Description Comments

    B C-Frame MKIV

    G C-Frame MKIV UL 1500

    Group 3: Mounting

    Code Description Comments

    2 Front mount round aperture, fleet Warning: Maximum penetration depth into the mounting screw is 5.4 mm

    3 Snap-in mount edges bevelled, without handle guards

    B Snap-in mount edges flush, without handle guards

    C Front mount round aperture, dome Required for UL listed products. Maximum penetration depth into the product by the mounting screw is 5.4 mm.

    S Front mount rectangular aperture flush rocker handle Warning: maximum penetration depth into the mounting screw is 5.4 mm

    Group 4: Handle

    Code Description Comments

    A Standard (toggle) handle For mountings 2, 3, B and C

    C Cut-off handle - single pole only For mountings 3, B, 2, C. Only 1 handle per unit

    H Flush rocker handle For mounting S only. Only 1 handle per unit. Reduced handle.

    M Flush rocker handle, two tone For mounting S only. Only 1 handle per unit. Reduced handle.

    Q Flush rocker handle, push-to-reset for mounting version S

    R Flush rocker handle, push-to-reset, two tone for mounting version S

    2 Standard handle, mid-trip For mountings 3, B, 22, C

    Group 5:Termination

    Code Description Comments Code Description Comments

    CX Quick connect terminal (0.8 mm x 6.35 mm) 30 A max 52Screw terminal 30o bent, bus connected

    (M5 or 10-32) 50 A max

    22 Screw terminal, bus connected (M5 or 10-32) 50 A max 62 Marine Screw Terminal (M5 or 10-32) 50 A max

    32 Screw terminal, upturned ears(M5 or 10-32) 50 A max ZZ Special - specify

    42 Screw terminal 30o bent, bus connected

    (M5 or 10-32) 50 A max

    Group 6: Number of Poles

    Code Description Code Description

    1 1 pole metric A 1 pole imperial

    2 2 pole metric B 2 pole imperial

    3 3 pole metric C 3 pole imperial

    4 4 pole metric D 4 pole imperial

    Group 7: Rated Voltage and Frequency - Main Circuit

    Code Description Comments

    E 65 V DC

    J 240 V 50 / 60 Hz

    K 277 V 50 / 60 Hz

    L 80 V DC / 277 V 50 / 60 Hz AC / DC version. With AC and DC curves

    M 80 V DC / 240 V 50 / 60 Hz AC / DC version. With AC and DC curves

    N 80 V DC

    Q 240 / 415 V 50 / 60 Hz 3 Phase multi-wire system

    R 277 / 480 V 50 / 60 Hz 3 Phase multi-wire system

    S 120 / 240 V 50 / 60 Hz 3 Wire centre tap supply. 120 V per phase

    Z Special - specify

    C Frame MKIV Series Circuit BreakersOrdering Information

  • CMKIV-SERIES-CATOCT 2016

    CataloguePage 4 of 29

    low voltage

    C Frame MKIV - Series Circuit BreakersC Frame MKIV - Series Circuit Breakers

    Group 8: Time Delay Characteristics (Curve Details); Pulse Tolerance at 10 ms

    Code Description System Pulse Tolerance (X In) Code Description System Pulse Tolerance (X In)

    AD Long delay 50 / 60 HzAS & dual rated AC and DC 8 -

    10 CH Short delay 50 / 60 HzCS & high inrush AC

    12 - 15

    BD Medium delay 50 / 60 HzBS & dual rated AC and DC 8 - 10 AS Long delay 50 / 60 Hz AC or DC 8 - 10

    CD Short delay 50 / 60 HzCS & dual rated AC and DC 6 - 8 BS Medium delay 50 / 60 Hz AC or DC 8 - 10

    AE Long delay 50 / 60 HzAH & inertia delay AC 28 - 35 CS Short delay 50 / 60 Hz AC or DC 6 - 8

    BE Medium delay 50 / 60 HzBH & inertia delay AC 28 - 35 AW

    Long delay 50 / 60 HzAD & inertia delay AC and DC 16 - 20

    CE Short delay 50 / 60 HzCH & inertia delay AC 21 - 35 BW

    Medium delay 50 / 60 HzBD & inertia delay AC and DC

    16 - 20

    AI Long delay 50 / 60 HzAS & inertia delay AC or DC 16 - 20 CW

    Short delay 50 / 60 HzCD & inertia delay AC and DC

    12 - 15

    BI Medium delay 50 / 60 HzBS & inertia delay AC or DC 16 - 20 H3 Short delay DC 6 - 8

    CI Short delay 50 / 60 HzCS & inertia delay AC or DC 12 - 15 OP Instantaneous trip 50 / 60 Hz AC and DC None

    AH Long delay 50 / 60 HzAS & high inrush AC 16 - 20 OX Switch 50 / 60 Hz AC and DC -

    BH Medium delay 50 / 60 HzBS & high inrush AC 16 - 20 ZZ Special - specify

    Group 9: Rated Current (Main Circuit) - Examples Only - Specific A Ratings Possible

    Code Description Comments

    XXXX Not applicable

    Examples only - specific A ratings possible from 0.5 - 50 A

    050M 50 mA

    100 1 A

    1000 10 A

    5000 50 A

    Group 10: Circuit Configuration (Circuit Breaker’s Internal Construction)

    Code Description Comments

    AX Switch

    BX Series trip Circuit breaker, current coil in series

    CX Relay Trip current sensing, centre terminal construction, four terminal Total load 50 A max

    DX Relay Trip voltage sensing, centre terminal construction, four terminal See group 12 for voltage options

    EX Shunt Trip current sensing, 3rd terminal close to load side Total load 50 A max

    FX Shunt Trip voltage sensing, 3rd terminal close to load side See group 12 for voltage options

    GX Dual control shunt trip construction, 3rd terminal close to load sideCurves AH, BH, CH, AE, BE, CE not possible. See group 12 for voltage options

    (voltage coil normally at line voltage).

    HX Dual control relay trip construction (4 terminal) Curves AH, BH, CH, AE, BE, CE not possible. See group 12 for voltage options

    JX Switch with auxiliary switch

    KX Series trip, with auxiliary switch

    ZZ Special - specify

    Group 11: Auxiliary and Alarm Switches

    Code Description Comments

    X Not applicable No Auxiliary Switch - flat base plate

    A Gold tips, equally spaced terminals 2.75 mm, 0.1 A max

    B Silver tips, equally spaced terminals 2.75 mm, 10 A max

    Z Special - specify

    Group 12: Voltage and Current Ratings for Dual Control, Shunt and Relay Trip Construction)

    Code Description Code Description Code Description Code Description

    XX Not applicable A5220 - 240 V AC

    50 / 60 HzB1 24 V DC B3 80 V DC

    A4110 - 125 V AC

    50 / 60 HzB0 12 V DC B2 48 V DC ZZ Special - specify

    Group 13: Voltage and Current Ratings for Dual Control, Shunt and Relay Trip Construction

    Code Description Comments

    X Not applicable

    B Screw terminal,s M4 or 10 - 32 50 A max

    C Quick connect terminals (0.8 mm x 6.35 mm) 30 A max

    C Frame MKIV Series Circuit BreakersOrdering Information

  • low voltage

    CMKIV-SERIES-CATOCT 2016

    CataloguePage 5 of 29

    C Frame MKIV - Series Circuit BreakersC Frame MKIV - Series Circuit Breakers

    C Frame MKIV Series Circuit BreakersOrdering Information

    For options not listed, please contact CBI

    Group 14: Voltage for Illuminated Rocker

    Code Description Comments

    X Not applicable

    Group 15: Terminal for Illuminated Rocker

    Code Description Comments

    X Not applicable

    Group 16: Handle Colour

    Code Description Comments

    X No handle

    B Black handle, white marking

    G Green handle, white marking

    W White handle, black marking

    R Red handle, white marking

    Y Yellow handle, black marking

    Group 17: Marking

    Code Description Comments

    X No handle (n/a)

    D 1 - 0 and ON - OFF For products requiring VDE approvals and UL mark (IEC / EN 60934 & UL 1077)

    H 1 - 0 and ON - OFF and Ampere rating

    I Push-to-reset and Ampere rating Group 3 option S only. Group 4 options Q or R only. Flush rocker or two tone rocker handle.

    Group 18: Mounting Orientation for Marking

    Code Description Comments

    X No handle (n/a)

    1 Vertical (reverse mounting, line @ bottom)

    2 Horizontal (line @ right)

    H Horizontal (line @ left)

    V Vertical (standard mounting, line @ top)

    Group 19: Front Plate Marking and Test Button

    Code Description Comments

    2 No marking, with test button, rocker handle

    A Standard marking, standard handle

    B No marking, rocker handle

    Group 20: Inter-phase Barrier and Terminal Cover

    Code Description Comments

    X Not applicable

    1 Terminal cover(s)

    2 Small inter-phase barrier and terminal cover

    4 Z inter-phase barrier and terminal cover

    A Small inter-phase barrier

    C Z inter-phase barrier

    Group 21: Approvals (Product Normally Approved to)

    Code Description Comments

    1 CUR, UL recognised UL 1077, CSA, IEC / EN 60934, VDE, CE

    2 CUL, UL listed UL 489, CSA, IEC / EN 60947-2, VDE, CE

    3 UL listed UL 489A, IEC / EN 60947-2, VDE, CE

    Z No third party approvals

    Group 22: Safety Marks

    Code Description Comments

    - Not applicable

    C CCC / CRCC

    Z Special - specify

    Group 13: Voltage and Current Ratings for Dual Control, Shunt and Relay Trip Construction

    Code Description Comments

    X Not applicable

    B Screw terminal,s M4 or 10 - 32 50 A max

    C Quick connect terminals (0.8 mm x 6.35 mm) 30 A max

  • CMKIV-SERIES-CATOCT 2016

    CataloguePage 6 of 29

    low voltage

    C Frame MKIV - Series Circuit BreakersC Frame MKIV 80 V DC - UL 489

    C Frame MKIV 80 V AC - UL 1077, CSA

    C Frame MKIV

    UL

    489A

    Poles 1 Pole 2 Pole80 V DC X X

    Fron

    t M

    ount

    Standard Handle 0.05 - 50 A ; 5 kA 0.05 - 50 A ; 5 kA

    Reduced Handle 0.05 - 50 A ; 5 kA 0.05 - 50 A ; 5 kA

    Cut-off Handle 0.05 - 50 A ; 5 kA 0.05 - 50 A ; 5 kA

    Rocker Handle Flush 0.05 - 50 A ; 5 kA 0.05 - 50 A ; 5 kA

    Series Trip X X

    Series Mid Trip X X

    Shunt Trip X X

    Relay Trip X X

    Dual Control Shunt Trip 30 VA voltage coils X X

    Dual Control Voltage Trip 30 VA voltage coils X X

    Time Delay AS longest tested. AI 30 A Max

    Term

    inal

    s

    Screw X X

    Quick Connect X X

    Plug-in 4 mm X X

    PCB Mount X X

    Marine Terminals X X

    Aux Switch Silver X X

    Aux Switch Gold X X

    cUR

    us U

    L 10

    77 C

    SA

    Poles 1 Pole 2 Pole80 V DC X X

    Fron

    t M

    ount

    Standard Handle 0.05 - 50 A ; 7.5 kA 0.05 - 50 A ; 7.5 kA

    Reduced Handle 0.05 - 50 A ; 7.5 kA 0.05 - 50 A ; 7.5 kA

    Cut-off Handle 0.05 - 50 A ; 7.5 kA 0.05 - 50 A ; 7.5 kA

    Rocker Handle Flush 0.05 - 50 A ; 7.5 kA 0.05 - 50 A ; 7.5 kA

    Series Trip X X

    Series Mid Trip X X

    Shunt Trip X X

    Relay Trip X X

    Dual Control Shunt Trip

    Dual Control Voltage Trip

    Time Delay AS, BS, CS, H3, AI, BI, CI, AD, BD, CD, AW, BW, CW, OP

    Term

    inal

    s

    Screw X X

    Quick Connect X X

    Plug-in 4 mm X X

    PCB Mount X X

    Marine Terminals X X

    Aux Switch Silver X X

    Aux Switch Gold X X

  • low voltage

    CMKIV-SERIES-CATOCT 2016

    CataloguePage 7 of 29

    C Frame MKIV - Series Circuit Breakers

    C Frame MKIV 80 V DC - UL 508 Recognised

    C Frame MKIV 80 V DC - IEC / EN 60934, CE, CCC

    UL

    508

    Rec

    ogni

    sed

    Poles 1 Pole 2 Pole80 V DC X X

    Fron

    t M

    ount

    Standard Handle 50 A 50 A

    Reduced Handle 50 A 50 A

    Cut-off Handle 50 A 50 A

    Rocker Handle Flush 50 A 50 A

    Series Trip

    Series Mid Trip

    Switch X X

    Shunt Trip X X

    Relay Trip X X

    Dual Control Shunt Trip

    Dual Control Voltage Trip

    Time Delay OX

    Term

    inal

    s

    Screw X X

    Quick Connect X X

    Plug-in 4 mm X X

    PCB Mount X X

    Marine Terminals X X

    Aux Switch Silver X X

    Aux Switch Gold X X

    IEC

    / E

    N 6

    0934

    VD

    E C

    E

    CC

    C

    Poles 1 Pole 2 Pole80 V DC X X

    Fron

    t M

    ount

    Standard Handle 0.05 - 50 A ; 4 kA 0.05 - 50 A ; 4 kA

    Reduced Handle 0.05 - 50 A ; 4 kA 0.05 - 50 A ; 4 kA

    Cut-off Handle 0.05 - 50 A ; 4 kA 0.05 - 50 A ; 4 kA

    Rocker Handle Flush 0.05 - 50 A ; 4 kA 0.05 - 50 A ; 4 kA

    Series Trip X X

    Series Mid Trip X X

    Shunt Trip X X

    Relay Trip X X

    Dual Control Shunt Trip X X

    Dual Control Voltage Trip X X

    Time Delay AS,BS, CS, H3, AI, BI, CI, AW, BW, CW, OP

    Term

    inal

    s

    Screw X X

    Quick Connect X X

    Plug-in 4 mm X X

    PCB Mount X X

    Marine Terminals X X

    Aux Switch Silver X X

    Aux Switch Gold X X

  • CMKIV-SERIES-CATOCT 2016

    CataloguePage 8 of 29

    low voltage

    C Frame MKIV - Series Circuit Breakers

    C Frame MKIV 120 V AC - UL 489, CSA

    C Frame MKIV 120 V, 120 / 240 V, 277 V AC - UL 1077, CSA

    cULu

    s U

    L 48

    9 C

    SA

    Poles 1 Pole 2 Pole

    120 V AC X X

    120 / 240 V X

    Fron

    t M

    ount

    Standard Handle 0.05 - 20 A ; 5 kA 0.05 - 20 A ; 5 kA

    Reduced Handle 0.05 - 20 A ; 5 kA 0.05 - 20 A ; 5 kA

    Cut-off Handle 0.05 - 20 A ; 5 kA 0.05 - 20 A ; 5 kA

    Rocker Handle Flush 0.05 - 20 A ; 5 kA 0.05 - 20 A ; 5 kA

    Series Trip X X

    Series Mid Trip X X

    Shunt Trip X X

    Relay Trip X X

    Dual Control Shunt Trip

    Dual Control Voltage Trip

    Time Delay AS longest tested

    Term

    inal

    s

    Screw X X

    Quick Connect X X

    Plug-in 4 mm X X

    PCB Mount X X

    Marine Terminals X X

    Aux Switch Silver X X

    Aux Switch Gold X X

    cUR

    us U

    L 10

    77 C

    SA

    Poles 1 Pole 2 Pole

    120 V AC X X

    120 / 240 V AC X277 V AC X

    Fron

    t M

    ount

    Standard Handle 0.05 - 50 A ; 2 kA 0.05 - 50 A ; 2 kA

    Reduced Handle 0.05 - 50 A ; 2 kA 0.05 - 50 A ; 2 kA

    Cut-off Handle 0.05 - 50 A ; 2 kA 0.05 - 50 A ; 2 kA

    Rocker Handle Flush 0.05 - 50 A ; 2 kA 0.05 - 50 A ; 2 kA

    Series Trip X X

    Series Mid Trip X X

    Shunt Trip X X

    Relay Trip X X

    Dual Control Shunt Trip X X

    Dual Control Voltage Trip X X

    Time Delay AS,BS, CS, H3, AI, BI, CI AH, BH, CH, AW, BW, CW, OP

    Term

    inal

    s

    Screw X X

    Quick Connect X X

    Plug-in 4 mm X X

    PCB Mount X X

    Marine Terminals X X

    Aux Switch Silver X X

    Aux Switch Gold X X

    Notes 3 kA with fuse @ 120 V AC

    5 kA with fuse

  • low voltage

    CMKIV-SERIES-CATOCT 2016

    CataloguePage 9 of 29

    C Frame MKIV - Series Circuit Breakers

    C Frame MKIV 240 V AC - UL 1077, CSA

    C Frame MKIV 120 V AC - UL 1500

    cUR

    us U

    L 10

    77 C

    SA

    Poles 1 Pole 2 Pole 3 Pole 4 Pole 5 Pole 6 Pole240 V AC X X X X X X

    Fron

    t M

    ount

    Standard Handle 0.05 - 50 A; 3 kA 0.05 - 50 A; 3 kA 0.05 - 50 A; 3 kA 0.05 - 50 A; 3 kA 0.05 - 50 A; 3 kA 0.05 - 50 A; 3 kA

    Reduced Handle 0.05 - 50 A; 3 kA 0.05 - 50 A; 3 kA 0.05 - 50 A; 3 kA 0.05 - 50 A; 3 kA 0.05 - 50 A; 3 kA 0.05 - 50 A; 3 kA

    Cut-off Handle 0.05 - 50 A; 3 kA 0.05 - 50 A; 3 kA 0.05 - 50 A; 3 kA 0.05 - 50 A; 3 kA 0.05 - 50 A; 3 kA 0.05 - 50 A; 3 kA

    Rocker Handle Flush 0.05 - 50 A; 3 kA 0.05 - 50 A; 3 kA 0.05 - 50 A; 3 kA 0.05 - 50 A; 3 kA 0.05 - 50 A; 3 kA 0.05 - 50 A; 3 kA

    Series Trip X X X X X X

    Series Mid Trip X X X X X X

    Shunt Trip X X X X X X

    Relay Trip X X X X X X

    Dual Control Shunt Trip X X X X X X

    Dual Control Voltage Trip X X X X X X

    Time Delay AS,BS, CS, H3, AI, BI, CI AH, BH, CH, AW, BW, CW, OP

    Term

    inal

    s

    Screw X X X X X X

    Quick Connect X X X X X X

    Plug-in 4 mm X X X X X X

    PCB Mount X X X X X X

    Marine Terminals X X X X X X

    Aux Switch Silver X X X X X X

    Aux Switch Gold X X X X X X

    UL

    1500

    Poles 1 Pole 2 Pole

    120 V AC X X

    Fron

    t M

    ount

    Standard Handle 0.05 - 50 A ; 1.5 kA 0.05 - 50 A ; 1.5 kA

    Reduced Handle 0.05 - 50 A ; 1.5 kA 0.05 - 50 A ; 1.5 kA

    Cut-off Handle 0.05 - 50 A ; 1.5 kA 0.05 - 50 A ; 1.5 kA

    Rocker Handle Flush 0.05 - 50 A ; 1.5 kA 0.05 - 50 A ; 1.5 kA

    Series Trip X X

    Series Mid Trip X X

    Shunt Trip X X

    Relay Trip X X

    Dual Control Shunt Trip X X

    Dual Control Voltage Trip X X

    Time Delay - -

    Term

    inal

    s

    Screw X X

    Quick Connect X X

    Plug-in 4 mm X X

    PCB Mount X X

    Marine Terminals X X

    Aux Switch Silver X X

    Aux Switch Gold X X

  • CMKIV-SERIES-CATOCT 2016

    CataloguePage 10 of 29

    low voltage

    C Frame MKIV - Series Circuit Breakers

    C Frame MKIV 240 V AC - IEC / EN 60934, VDE, CE, CCC

    C Frame MKIV 240 V AC - UL 508 Recognised

    IEC

    / E

    N 6

    0934

    VD

    E C

    E

    CC

    C

    Poles 1 Pole 2 Pole 3 Pole 4 Pole240 V AC X X X X

    Fron

    t M

    ount

    Standard Handle 0.05 - 50 A; 2 kA 0.05 - 50 A; 2 kA 0.05 - 50 A; 2 kA 0.05 - 50 A; 2 kA

    Reduced Handle 0.05 - 50 A; 2 kA 0.05 - 50 A; 2 kA 0.05 - 50 A; 2 kA 0.05 - 50 A; 2 kA

    Cut-off Handle 0.05 - 50 A; 2 kA 0.05 - 50 A; 2 kA 0.05 - 50 A; 2 kA 0.05 - 50 A; 2 kA

    Rocker Handle Flush 0.05 - 50 A; 2 kA 0.05 - 50 A; 2 kA 0.05 - 50 A; 2 kA 0.05 - 50 A; 2 kA

    Series Trip X X X X

    Series Mid Trip X X X X

    Shunt Trip X X X X

    Relay Trip X X X X

    Dual Control Shunt Trip X X X X

    Dual Control Voltage Trip X X X X

    Time Delay AS,BS, CS, H3, AI, BI, CI AH, BH, CH, AW, BW, CW, OP

    Term

    inal

    s

    Screw X X X X

    Quick Connect X X X X

    Plug-in 4 mm X X X X

    PCB Mount X X X X

    Marine Terminals X X X X

    Aux Switch Silver X X X X

    Aux Switch Gold X X X X

    Notes 5 kA with fuse

    UL

    508

    Rec

    ogni

    sed

    Poles 1 Pole 2 Pole 3 Pole 4 Pole240 V AC X X X X

    Fron

    t M

    ount

    Standard Handle 50 A 50 A 50 A 50 A

    Reduced Handle 50 A 50 A 50 A 50 A

    Cut-off Handle 50 A 50 A 50 A 50 A

    Rocker Handle Flush 50 A 50 A 50 A 50 A

    Series Trip

    Series Mid Trip

    Switch X X X X

    Shunt Trip X X X X

    Relay Trip X X X X

    Dual Control Shunt Trip

    Dual Control Voltage Trip

    Time Delay OX

    Term

    inal

    s

    Screw X X X X

    Quick Connect X X X X

    Plug-in 4 mm X X X X

    PCB Mount X X X X

    Marine Terminals X X X X

    Aux Switch Silver X X X X

    Aux Switch Gold X X X X

  • low voltage

    CMKIV-SERIES-CATOCT 2016

    CataloguePage 11 of 29

    C Frame MKIV - Series Circuit Breakers

    C Frame MKIV 277 V AC - UL 1077, CSA

    C Frame MKIV 240 V AC - UL 508 Listed

    cUR

    us U

    L 10

    77 C

    SA

    Poles 1 Pole277 V AC X

    Fron

    t M

    ount

    Standard Handle 0.05 - 30 A ; 2 kA

    0.05 - 30 A Motor Starter

    Reduced Handle 0.05 - 30 A ; 2 kA

    Cut-off Handle 0.05 - 30 A ; 2 kA

    Rocker Handle Flush 0.05 - 30 A ; 2 kA

    Series Trip X

    Series Mid Trip X

    Shunt Trip X

    Relay Trip X

    Dual Control Shunt Trip X

    Dual Control Voltage Trip X

    Time Delay AS,BS, CS, H3, AI, BI, CI AH, BH, CH, AW, BW, CW, OP

    Term

    inal

    s

    Screw X

    Quick Connect X

    Plug-in 4 mm X

    PCB Mount X

    Marine Terminals X

    Aux Switch Silver X

    Aux Switch Gold X

    Notes 5 kA with fuse

    UL

    508

    List

    ed

    Poles 1 Pole240 V AC X

    Fron

    t M

    ount

    Standard Handle 50 A

    Reduced Handle 50 A

    Cut-off Handle 50 A

    Rocker Handle Flush 50 A

    Series Trip

    Series Mid Trip

    Switch X

    Shunt Trip X

    Relay Trip X

    Dual Control Shunt Trip

    Dual Control Voltage Trip

    Time Delay OX

    Term

    inal

    s

    Screw X

    Quick Connect X

    Plug-in 4 mm X

    PCB Mount X

    Marine Terminals X

    Aux Switch Silver X

    Aux Switch Gold X

  • CMKIV-SERIES-CATOCT 2016

    CataloguePage 12 of 29

    low voltage

    C Frame MKIV - Series Circuit Breakers

    PERCENTAGE OF RATED CURRENT

    TR

    IP T

    IME

    IN S

    ECO

    ND

    S

    TYPICAL TIME / CURRENT CHARACTERISTICS AT 25°C

    DUAL RATED LONG DELAY50 / 60 Hz DC

    CODE: ADNOTE: 8 X INRUSH

    }

    PERCENTAGE OF RATED CURRENT

    TR

    IP T

    IME

    IN S

    ECO

    ND

    S

    TYPICAL TIME / CURRENT CHARACTERISTICS AT 25°C

    DUAL RATED MEDIUM DELAY50 / 60 Hz DC

    CODE: BDNOTE: 8 X INRUSH

    }

    C Frame MKIV Time Delay Curves

  • low voltage

    CMKIV-SERIES-CATOCT 2016

    CataloguePage 13 of 29

    C Frame MKIV - Series Circuit Breakers

    PERCENTAGE OF RATED CURRENT

    TR

    IP T

    IME

    IN S

    ECO

    ND

    S

    TYPICAL TIME / CURRENT CHARACTERISTICS AT 25°C

    DUAL RATED SHORT DELAY50 / 60 Hz DC

    CODE: CDNOTE: 6 X INRUSH

    }

    C Frame MKIV Time Delay Curves

    PERCENTAGE OF RATED CURRENT

    TR

    IP T

    IME

    IN S

    ECO

    ND

    S

    TYPICAL TIME / CURRENT CHARACTERISTICS AT 25°C

    50 / 60 Hz DC HIGH-INRUSH LONG DELAY

    CODE: AH /AENOTE: AH - 20 x INRUSH, AE 35 x INRUSH

    }

  • CMKIV-SERIES-CATOCT 2016

    CataloguePage 14 of 29

    low voltage

    C Frame MKIV - Series Circuit Breakers

    PERCENTAGE OF RATED CURRENT

    TR

    IP T

    IME

    IN S

    ECO

    ND

    S

    TYPICAL TIME / CURRENT CHARACTERISTICS AT 25°C

    50 / 60 Hz HIGH-INRUSH MEDIUM DELAY

    CODE: BH / BENOTE: BH - 20 X INRUSH, BE 25 X INRUSH

    }

    C Frame MKIV Time Delay Curves

    PERCENTAGE OF RATED CURRENT

    TR

    IP T

    IME

    IN S

    ECO

    ND

    S

    TYPICAL TIME / CURRENT CHARACTERISTICS AT 25°C

    HIGH-RUSH SHORT DELAY 50 / 60 Hz

    CODE: CH / CENOTE: CH -15 X INRUSH, CE - 35 X INRUSH

    }

  • low voltage

    CMKIV-SERIES-CATOCT 2016

    CataloguePage 15 of 29

    C Frame MKIV - Series Circuit Breakers

    PERCENTAGE OF RATED CURRENT

    TR

    IP T

    IME

    IN S

    ECO

    ND

    S

    TYPICAL TIME / CURRENT CHARACTERISTICS AT 25°C

    50 / 60 Hz DC LONG DELAY WITH INRUSH PULSE TOLERANCE

    CODE: AINOTE: 20 x INRUSH

    }

    PERCENTAGE OF RATED CURRENT

    TR

    IP T

    IME

    IN S

    ECO

    ND

    S

    TYPICAL TIME / CURRENT CHARACTERISTICS AT 25°C

    50 / 60 Hz DC MEDIUM DELAY WITH INRUSH PULSE TOLERANCE

    CODE: BINOTE: 20 X INRUSH

    }

    C Frame MKIV Time Delay Curves

  • CMKIV-SERIES-CATOCT 2016

    CataloguePage 16 of 29

    low voltage

    C Frame MKIV - Series Circuit Breakers

    PERCENTAGE OF RATED CURRENT

    TR

    IP T

    IME

    IN S

    ECO

    ND

    S

    TYPICAL TIME / CURRENT CHARACTERISTICS AT 25°C

    50 / 60 Hz DC LONG DELAY WITH INRUSH PULSE TOLERANCE

    CODE: CINOTE: 15 x INRUSH

    }

    C Frame MKIV Time Delay Curves

    PERCENTAGE OF RATED CURRENT

    TR

    IP T

    IME

    IN S

    ECO

    ND

    S

    TYPICAL TIME / CURRENT CHARACTERISTICS AT 25°C

    50 / 60 Hz DC LONG DELAY

    CODE: ASNOTE: 8 x INRUSH

    }

  • low voltage

    CMKIV-SERIES-CATOCT 2016

    CataloguePage 17 of 29

    C Frame MKIV - Series Circuit Breakers

    PERCENTAGE OF RATED CURRENT

    TR

    IP T

    IME

    IN S

    ECO

    ND

    S

    TYPICAL TIME / CURRENT CHARACTERISTICS AT 25°C

    50 / 60 Hz DC MEDIUM DELAY

    CODE: BSNOTE: 8 X INRUSH

    }

    PERCENTAGE OF RATED CURRENT

    TR

    IP T

    IME

    IN S

    ECO

    ND

    S

    TYPICAL TIME / CURRENT CHARACTERISTICS AT 25°C

    50 / 60 Hz DC SHORT DELAY WITH

    CODE: CSNOTE: 6 X INRUSH

    }

    C Frame MKIV Time Delay Curves

  • CMKIV-SERIES-CATOCT 2016

    CataloguePage 18 of 29

    low voltage

    C Frame MKIV - Series Circuit Breakers

    PERCENTAGE OF RATED CURRENT

    TR

    IP T

    IME

    IN S

    ECO

    ND

    S

    TYPICAL TIME / CURRENT CHARACTERISTICS AT 25°C

    DUAL RATED LONG DELAY WITH50 / 60 Hz DC INRUSH PULSE TOLERANCE

    CODE: AWNOTE: 20 x INRUSH

    }

    C Frame MKIV Time Delay Curves

    PERCENTAGE OF RATED CURRENT

    TR

    IP T

    IME

    IN S

    ECO

    ND

    S

    TYPICAL TIME / CURRENT CHARACTERISTICS AT 25°C

    DUAL RATED MEDIUM DELAY WITH50 / 60 Hz DC INRUSH PULSE TOLERANCE

    CODE: BWNOTE: 20 X INRUSH

    }

  • low voltage

    CMKIV-SERIES-CATOCT 2016

    CataloguePage 19 of 29

    C Frame MKIV - Series Circuit Breakers

    PERCENTAGE OF RATED CURRENT

    TR

    IP T

    IME

    IN S

    ECO

    ND

    S

    TYPICAL TIME / CURRENT CHARACTERISTICS AT 25°C

    DUAL RATED SHORT DELAY WITH50 / 60 Hz INSTANTANEOUS

    CODE: CWNOTE: 15 X INRUSH

    }

    C Frame MKIV Time Delay Curves

    % %%%%%%%%%%%%%PERCENTAGE OF RATED CURRENT

    MINIMUM TRIP TIMEIN SECONDS

    MAXIMUM TRIP TIMEIN SECONDS

    NOTRIPNOTRIP

    PERCENTAGE OF RATED CURRENT

    TR

    IP T

    IME

    IN S

    ECO

    ND

    S

    TYPICAL TIME / CURRENT CHARACTERISTICS AT 25°C

    50 / 60 Hz DC SHORT DELAY

    CODE: H3

    }

  • CMKIV-SERIES-CATOCT 2016

    CataloguePage 20 of 29

    low voltage

    C Frame MKIV - Series Circuit Breakers

    PERCENTAGE OF RATED CURRENT

    TR

    IP T

    IME

    IN S

    ECO

    ND

    S

    TYPICAL TIME / CURRENT CHARACTERISTICS AT 25°C

    50 / 60 Hz DC INSTANTANEOUS

    CODE: OP

    }

    C Frame MKIV Time Delay Curves

  • low voltage

    CMKIV-SERIES-CATOCT 2016

    CataloguePage 21 of 29

    C Frame MKIV - Series Circuit Breakers

    C F

    ram

    e M

    KIV

    Sta

    ndar

    d H

    andl

    e (D

    ome

    Mou

    nt)

    Out

    line

    Dim

    ensi

    ons

  • CMKIV-SERIES-CATOCT 2016

    CataloguePage 22 of 29

    low voltage

    C Frame MKIV - Series Circuit Breakers

    C F

    ram

    e M

    KIV

    Sta

    ndar

    d H

    andl

    e (D

    ome

    Mou

    nt)

    Out

    line

    Dim

    ensi

    ons

  • low voltage

    CMKIV-SERIES-CATOCT 2016

    CataloguePage 23 of 29

    C Frame MKIV - Series Circuit Breakers

    C F

    ram

    e M

    KIV

    Sta

    ndar

    d R

    educ

    ed H

    andl

    e O

    utlin

    e D

    imen

    sion

    s

  • CMKIV-SERIES-CATOCT 2016

    CataloguePage 24 of 29

    low voltage

    C Frame MKIV - Series Circuit Breakers

    C F

    ram

    e M

    KIV

    Fle

    et M

    ount

    Han

    dle

    Out

    line

    Dim

    ensi

    ons

  • low voltage

    CMKIV-SERIES-CATOCT 2016

    CataloguePage 25 of 29

    C Frame MKIV - Series Circuit Breakers

    C F

    ram

    e M

    KIV

    Fle

    et R

    educ

    ed H

    andl

    e O

    utlin

    e D

    imen

    sion

    s

  • CMKIV-SERIES-CATOCT 2016

    CataloguePage 26 of 29

    low voltage

    C Frame MKIV - Series Circuit Breakers

    C F

    ram

    e M

    KIV

    Roc

    ker

    Han

    dle

    Out

    line

    Dim

    ensi

    ons

  • low voltage

    CMKIV-SERIES-CATOCT 2016

    CataloguePage 27 of 29

    C Frame MKIV - Series Circuit Breakers

    C F

    ram

    e M

    KIV

    Rel

    ay a

    nd S

    hunt

    Tri

    p U

    nits

    Out

    line

    Dim

    ensi

    ons

  • CMKIV-SERIES-CATOCT 2016

    Data SheetPage 28 of 29

    low voltage

    C Frame MKIV - Series Circuit Breakers

    C F

    ram

    e M

    KIV

    Ada

    ptor

    Pla

    tes

    Out

    line

    Dim

    ensi

    ons

  • Please review our Customer Terms and Conditions on www.cbi-lowvoltage.co.zaAll rights reserved. Unless otherwise indicated, all materials on these pages are copyrighted by CBI (Pty) Ltd. No part of these pages, either text or image may be used for any purpose other than personal use. Therefore, reproduction, modification, storage in a retrieval system or retransmission, in any form or by any means, electronic, mechanical or otherwise, for reasons other than personal use, is strictly prohibited without prior written permission. CBI (Pty) Ltd reserves the right to alter any details of this document without notice and while every effort is made to ensure the accuracy of the content, no warranty is given as to accuracy of this document and no responsibility will be accepted for error or misinterpretation and any resulting loss.

    CMKIV-SERIES-CATOCT 2016

    low voltage

    Data SheetPage 29 of 29

    A member of the Group

    © 2016.09 CBI (Pty) Ltd. All Rights Reserved.

    SCANDINAVIAEmcomp International ABBox 7, Hemvägen 12732 71, Fellingsbro SwedenTel: +46 (0)581 62 15 50Fax: +46 (0)581 62 15 60Email: [email protected]: www.emcomp.se

    EUROPEEmcomp International ABGewerbepark 2385250 Altomünster GermanyTel: +49 8254 994 334 10Fax: +49 8254 994 334 19Email: [email protected]: www.emcomp.de

    C Frame MKIV - Series Circuit Breakers

    C F

    ram

    e M

    KIV

    Rea

    r In

    ter-

    phas

    e B

    arri

    ers

    Out

    line

    Dim

    ensi

    ons