ca3/ca1/ca1h - maxtech inst

2
CA3/CA1/CA1H High voltages are often needed to provide test currents for older electro-mechanical relays. The three-phase switched current amplifier designated CA3 solves this problem. It can provide 3 x 30 A or 1 x 60 A connected in parallel. Maximum output power is 600 VA (3 x 25 A at 8 V). If higher voltage is needed, you can make the connection between two phases (L-L). If a higher voltage is needed than the CA3 can provide, or if you want to use a single-phase current amplifier, you should choose the CA1 or CA1H (H stands for high voltage). They can provide 1 x 60 A and 1 x 24 A respec- tively. If you need even higher current, two or more current amplifiers can be connected in parallel, thus bringing the output current up to 180 A. The current amplifiers can also be used in situations where more current generators are needed than the three built into FREJA. Since the amplifiers can be controlled by both current and voltage, they can be connected to FREJA's voltage generators. The number of current generators can thus be increased to six, which is con- venient when testing differential relays. CA3/CA1/CA1H Current Amplifiers

Upload: others

Post on 03-Feb-2022

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CA3/CA1/CA1H - Maxtech Inst

CA3

/CA1

/CA1

H

High voltages are often needed to provide test currents for older electro-mechanical relays. The three-phase

switched current amplifier designated CA3 solves this problem. It can provide 3 x 30 A or 1 x 60 A connected in

parallel. Maximum output power is 600 VA (3 x 25 A at 8 V). If higher voltage is needed, you can make the

connection between two phases (L-L).

If a higher voltage is needed than the CA3 can provide, or if you want to use a single-phase current amplifier,

you should choose the CA1 or CA1H (H stands for high voltage). They can provide 1 x 60 A and 1 x 24 A respec-

tively. If you need even higher current, two or more current amplifiers can be connected in parallel, thus bringing

the output current up to 180 A.

The current amplifiers can also be used in situations where more current generators are needed than the

three built into FREJA. Since the amplifiers can be controlled by both current and voltage, they can be connected

to FREJA's voltage generators. The number of current generators can thus be increased to six, which is con-

venient when testing differential relays.

CA3/CA1/CA1HCurrent Amplifiers

Page 2: CA3/CA1/CA1H - Maxtech Inst

CA3

/CA1

/CA1

HSPECIFICATIONS

CA3CURRENT OUTPUTSSetting range

3-phase AC: 3 x 0 - 30 A (symmetrical phases)

1-phase AC1): 1 x 0 - 60 A

3-channel DC: 3 x ± 20 A1) Parallel connection of generators

Power3-phase AC: 600 VA, 3 x 200 VA (8 V at 25 A)

1-phase AC (L-L): 1 x 480 VA at 30 A (16 V)

1-phase AC1): 1 x 400 VA at 50 A (8 V)

Time limits

0 - 7 A: Continuous

>7 A: 10 s

Phase accuracy ± 0.2°

Distortion 1% max, 0.1% typical

Accuracy ± (0.4% of actual value + 0.1% of range)The above technical data are for resistive load 10 - 150 mOhm.

GENERALMains voltage 105 - 264 V AC, 47-63 Hz

Operating temperature 0 to +50°C (+32 to +122°F)

Storage temperature -40 to +70°C (-40 to +158°F)

Dimensions 450 x 132 x 410 mm

(17.7" x 5.2" x 16.1")

Weight 11 kg (24 lbs)

CA1CURRENT OUTPUTSSetting range

1-phase AC: 1 x 0 - 60 A

1-phase AC: 1 x 0 - 180 A (3 CA1 in parallel)

1-channel DC: 1 x ± 60 A

Power

1-phase AC: 560 VA, 9.3 V at 60 A

1-phase AC: 1680 VA, 9.3 V at 180 A (3 CA1 in parallel)

Time limits

0 - 20 A: Continuous

20 - 60 A: 10 s

Phase accuracy ± 0.3°

Distortion 2% max, 0.5% typical

Accuracy ± (1% of actual value + 0.2% of range)

CA1HCURRENT OUTPUTSSetting range

1-phase AC: 1 x 0 - 20 A

1-phase AC: 1 x 0 - 60 A (3 CA1H in parallel)

1-channel DC: 1 x ± 20 A

Power

1-phase AC: 600 VA, 25 V at 24 A

1-phase AC: 1800 VA, 25 V at 72 A (3 CA1H in parallel)

Time limits

0 - 8 A: Continuous

8 - 24 A: 10 s

Phase accuracy ± 0.3°

Distortion 2% max, 0.5% typical

Accuracy ± (1% of actual value + 0.2% of range)

GENERAL FOR CA1 AND CA1HMains voltage 115/230 V AC (switchable) ± 10%, 50-60 Hz

Operating temperature 0 to +45°C (+32 to +113°F)

Storage temperature -40 to +70°C (-40 to +158°F)

Dimensions 500 x 300 x 245 mm

(19.6" x 11.8" x 9.6")

Weight 20 kg (44 lbs)

The above specifications are valid at nominal input voltage andan ambient temperature of +25°C (+77°F). Specifications aresubject to change without notice.

SPECIFICATIONS

ORDERING INFORMATION

CA3CA3 including hard transport case GD-00210

Art.No: CA-19090

Soft transport case for CA3

Art.No: GD-00215

CA1CA1 including hard transport case GD-00170

Art.No: CB-19090

CA1HCA1H including hard transport case GD-00170

Art.No: CB-29090

CA1/CA1HCA3/CA1/CA1H Output voltage

Current (A)

Out

put

volt

age

(V)