CABLE ACCESSORIES Separable Connectors 600 Series Deadbreak 0 Thomas & Betts Corporation 8155 T&B Boulevard Memphis TN 38125 800.888.0211 www.tnb.com/utility PG-CA-0307 600 Series deadbreak elbows, straight receptacles, junctions, vault stretchers and accessories are used to connect equipment and cable on primary feeder and network circuits. Designs accom- modate large conductors and feature bolted connections and deadfront modular construction for maximum reliability, perfor- mance and versatility. DE-ENERGIZED connectors can be quickly and easily connected and disconnected using standard hand tools and equipment in ac- cordance with accepted operating practices. Optional accessories allow visible external separation, by-pass, isolation, dead-ending, grounding, and testing as well as adding taps, surge arresters and circuit protection. Hotstick operable and separable joint systems are shown on pages 14 thru 19. RATINGS OVERVIEW See page 2 for complete information. CURRENT RATINGS (Prefixes: 650, K650, K655, K656, 750, 755, 756 & 03700) 600 Amp Continuous 25kA sym., 10 cycles (Prefixes 675, K675, K676, 775, 776 & 03702) 900 Amp Continuous 25kA sym., 10 cycles NOTE: 900 Amp ratings require copper cable and copper current-carrying components. VOLTAGE RATINGS 5/25kV Class (5kV thru 28kV) 16.2kV Phase-to-Ground 28kV Phase-to Phase 140kV BIL 45kV AC Withstand 84kV DC Withstand 21.5kV Corona Extinction 35kV Class 21.1kV Phase-to-Ground 36.6kV Phase-to-Phase 150kV BIL 50kV AC Withstand 103kV DC Withstand 26kV Corona Extinction Note: Elastimold has increased the IEEE Standard Production and Design Test levels for 25kV Class products to include 27kV and 28kV systems. INTEGRAL BUSHING RETAINING RING CABLE TO EQUIPMENT COMPRESSION LUG CABLE ADAPTER CABLE TO CABLE STRAIGHT RECEPTACLE HOUSING LOADBREAK ELBOW TAP PLUG 200A LOADBREAK SEE PAGES 4 & 5 200A DEADBREAK SEE PAGES 8 & 9 LINK-OP LINK CONNECTOR SPANNER WRENCH OPERATING ACCESSORIES 4 PT JUNCTION 3 PT JUNCTION 2 PT JUNCTION HOTSTICK OPERABLE 600 SERIES CONNECTORS - SEE PAGES 14 - 17 STICK-OP LINK-OP COMPRESSION LUG CABLE ADAPTER VAULT STRETCHER CONNECTOR L-1 UTILIZING L-KITS L-2 ELBOW CONNECTOR STICK-OP LOADBREAK REDUCING TAP PLUG BOLT & WASHERS STRAIGHT RECEPTACLE ADAPTER L-3 L-4 THREADED STUD LINK-OP RETAINER SLEEVES 200A TAPS INSULATING PLUG INSULATED PARKING BUSHING BUSHING EXTENDER THREADED COMPRESSION LUG 600 SERIES ELBOW CABLE ADAPTER COMPRESSION LUG CONNECTING PLUG STRAIGHT RECEPTACLE REDUCING TAP WELL THREADED STUD VOLTAGE DETECTION CAP INSULATED CAP WITH TEST POINT GROUNDING PLUG DEADBREAK REDUCING TAP PLUG 600 SERIES TAPS CAM-OP RETAINER SLEEVES CONNECTING PLUG VAULT STRETCHER BUSHING EXTENDER THREADED STUD THREADED STUD WINDOW-OP SEE PGS 16 &17 CAM-OP CABLE ADAPTER COMPRESSION LUG SEE PGS 12 & 13 SEE PGS 20 & 21 FOR ADDITIONAL JUNCTIONS SEE PGS 12 & 13 CAM-OP LINK CONNECTOR SEE PGS 14 & 15 SEE PGS 14 & 15 SEE PGS 16 & 17 VS2 VS3 VS4 VAULT STRETCHERS CABLE TO CABLE UTILIZING (UTILIZING JUNCTIONS) CABLE TO CABLE SEE PRODUCT GUIDE PG-PC-E FOR SURGE ARRESTER APPLICATIONS 600 Series Deadbreak SEPARABLE CONNECTORS 600 SERIES DEADBREAK

Upload: tranngoc

Post on 27-Jul-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CABLE ACCESSORIES - Border States Electric€¦ · PG-CA-0307 Use Tables W9 and X6 CAM-OP and

CABLE ACCESSORIESSe

para

ble

Con

nect

ors

600

Serie

s D

eadb

reak

�0 Thomas & Betts Corporation 8155 T&B Boulevard Memphis TN 38125 800.888.0211 www.tnb.com/utility PG-CA-0307

600 Series deadbreak elbows, straight receptacles, junctions, vault stretchers and accessories are used to connect equipment and cable on primary feeder and network circuits. Designs accom-modate large conductors and feature bolted connections and deadfront modular construction for maximum reliability, perfor-mance and versatility.

DE-ENERGIzED connectors can be quickly and easily connected and disconnected using standard hand tools and equipment in ac-cordance with accepted operating practices. Optional accessories allow visible external separation, by-pass, isolation, dead-ending, grounding, and testing as well as adding taps, surge arresters and circuit protection.

Hotstick operable and separable joint systems are shown on pages 14 thru 19.

rATinGS oVErViEWSee page 2 for complete information.CUrrEnT rATinGS(Prefixes: 650, K650, K655, K656, 750, 755, 756 & 03700)600 Amp Continuous25kA sym., 10 cycles(Prefixes 675, K675, K676, 775, 776 & 03702)900 Amp Continuous25kA sym., 10 cyclesNOTE: 900 Amp ratings require copper cable and copper current-carrying components.

VoLTAGE rATinGS�5/25kV Class (5kV thru 28kV) 16.2kV Phase-to-Ground 28kV Phase-to Phase 140kV BIL 45kV AC Withstand 84kV DC Withstand 21.5kV Corona Extinction35kV Class 21.1kV Phase-to-Ground 36.6kV Phase-to-Phase 150kV BIL 50kV AC Withstand 103kV DC Withstand 26kV Corona ExtinctionNote: Elastimold has increased the IEEE Standard Production and Design Test levels for 25kV Class products to include 27kV and 28kV systems.

INTEGRAL BUSHING

RETAININGRING

CABLE TO EQUIPMENT

COMPRESSIONLUG

CABLEADAPTER

CABLE TO CABLE

STRAIGHT RECEPTACLEHOUSING

LOADBREAKELBOW

TAP PLUG

200A LOADBREAKSEE PAGES 4 & 5

200A DEADBREAKSEE PAGES 8 & 9

LINK-OPLINK CONNECTOR

SPANNER WRENCH

OPERATINGACCESSORIES

4 PT JUNCTION

3 PT JUNCTION

2 PT JUNCTION

HOTSTICK OPERABLE 600 SERIESCONNECTORS - SEE PAGES 14 - 17

STICK-OP

LINK-OP

COMPRESSIONLUG

CABLEADAPTER

VAULTSTRETCHER

CONNECTOR

L-1

UTILIZING L-KITS

L-2

ELBOW CONNECTOR

STICK-OPLOADBREAK REDUCING

TAP PLUG

BOLT &WASHERS

STRAIGHTRECEPTACLE ADAPTER

L-3

L-4

THREADEDSTUD

LINK-OPRETAINERSLEEVES

200A TAPS

INSULATINGPLUG

INSULATEDPARKING BUSHING

BUSHINGEXTENDER

THREADEDCOMPRESSION

LUG

600 SERIESELBOW

CABLEADAPTER

COMPRESSIONLUG

CONNECTINGPLUG

STRAIGHT RECEPTACLE

REDUCING TAPWELL

THREADEDSTUD VOLTAGE

DETECTIONCAP

INSULATED CAPWITH TEST POINT

GROUNDINGPLUG

DEADBREAKREDUCINGTAP PLUG600 SERIES

TAPS

CAM-OPRETAINERSLEEVES

CONNECTINGPLUG

VAULTSTRETCHER

BUSHINGEXTENDER

THREADEDSTUD

THREADEDSTUD

WINDOW-OPSEE PGS 16 &17

CAM-OPCABLE

ADAPTER

COMPRESSIONLUG

SEE PGS 12 & 13

SEE PGS 20 & 21 FORADDITIONAL JUNCTIONS

SEE PGS 12 & 13

CAM-OPLINK CONNECTOR

SEE PGS 14 & 15

SEE PGS 14 & 15

SEE PGS 16 & 17VS2

VS3

VS4

VAULT STRETCHERSCABLE TO CABLE UTILIZING

(UTILIZING JUNCTIONS)CABLE TO CABLE

SEE PRODUCT GUIDE PG-PC-E FOR SURGE ARRESTER

APPLICATIONS

600 Series Deadbreak

SEPArABLE ConnECTorS 600 SEriES DEADBrEAK

Page 2: CABLE ACCESSORIES - Border States Electric€¦ · PG-CA-0307 Use Tables W9 and X6 CAM-OP and

Separable Connectors

600 Series Deadbreak

CABLE ACCESSORIES

��Thomas & Betts Corporation 8155 T&B Boulevard Memphis TN 38125 800.888.0211 www.tnb.com/utilityPG-CA-0307

illustration Description Voltage ELASTimoLD notes (not to scale) Class Part number

600 Series Elbow 15/25kV K655Lr-W0X N1,2,12 (w/ Insul. Plug, Cap, Stud, Use Tables W7 and X6 Lug and Cable Adapter) 35kV 755Lr-W0X N1,2,12 Use Tables W9 and X6 600 Series Direct 15/25kV K655DLr-W0X N1,2,12,14 Test Elbow (w/ Insul. Plug, Cap, Stud 35kV 755DLr-W0X N1,2,12,14 Lug and Cable Adapter) 600 Series Elbow 15/25kV K656Lr-W0X N1,2,12 w/ Test Point Use Tables W7 and X6 (w/ Insul. Plug, Cap, Stud, 35kV 756Lr-W0X N1,2,12 Lug and Cable Adapter) Use Tables W9 and X6 600 Series Direct 15/25kV K656DLr-W0X N1,2,12,14 Test Elbow w/Test Point Use Tables W7 and X6 (w/ Insul. Plug, Cap, Stud, 35kV 756DLr-W0X N1,2,12,14 Lug and Cable Adapter) Use Tables W9 and X6 600 Series Elbow 15/25kV K655BLr N1,3 Housing only 35kV 755BLr N1,3 (w/ Stud) 600 Series Elbow 15/25kV K656BLr N1,3 w/ Test Point 35kV 756BLr N1,3 Housing only (w/ Stud) 600 Series 15/25kV K655BrLr N,16 Replacement Elbow Housing only w/o Test Point 600 Series 15/25kV K656BrLr N,16 Replacement Elbow Housing only w/ Test Point 600 Series Straight 15/25kV K655Sr-W0X N1,2,11 Receptacle Use Tables W7 and X6 (w/ Cable Adapter, Lug & Retaining Ring) 600 Series Direct 15/25kV K655DSr-W0X N1,2,11,14 Test Straight Use Tables W7 and X6 Receptacle Elbow 600 Series Straight 15/25kV K655BSr N1,11 Receptacle Housing (Lug & Cable Adapter not included) Straight Receptacle 15/25kV K650SrA N1,4 Adapter 600 Series 15/25kV K655BVS N1,9 Vault Stretcher (Housing only 35kV 755BVS N1,9 w/ Stud) Cable Size 15/25kV 655CA-W Adapter Use Table W7 35kV 755CA-W Use Table W9 Compression ALL 03700X N5 Lug Use Table X6 ALL 03702X N6 Use Table X6 600 Series Elbow 15/25kV 655CK-W0X N2 & Vault Stretcher Use Tables W7 and X6 Size Sensitive Kit (Cable Adapter 35kV 755CK-W0X N2 & Lug) Use Tables W9 and X6 Adapter ALL 650Arr-X Retaining Ring Use Table X6 600 Series Straight 15/25kV 655CK-W0X-Arr N2 Receptacle Size Use Tables W7 and X6 Sensitive Kit (Cable Adapter, Retaining Ring & Lug) Bushing 15/25kV K655BE N1,3 Extender 35kV 755BE N1,3 (w/ Stud) Insulated Cap 15/25kV K656Dr N3,7 w/ Test Point (w/ Stud) Insulating Plug 15/25kV K650BiP N1,7,8 (w/ Cap) 35kV 750BiP N1,7,8

illustration Description Voltage ELASTimoLD notes (not to scale) Class Part number

Grounding Plug 15/25kV 650GP N1,7,8 (Ground Lead 35kV 750GP N1,7,8 2/0 AWG x 30”) Insulated 15/25kV K650SoP N7,8 Parking Bushing 35kV 750SoP N7,8 Connecting Plug 15/25kV K650CP N1,7,8,9,13 15/25kV K65�CP N1,7,8,10 35kV 750CP N1,7,8,10 Deadbreak 15/25kV K650rTP N1,7,8,9 Reducing Tap Plug Reducing Tap 15/25kV K650rTW N1,7,8,9 Well Loadbreak 15kV 650ETP N1,7,8,10,12 Elbow 25kV K650ETP N1,7,8,10,12 Tap Plug 35kV 750ETP N1,7,8,10,12 Vault Stretcher 15/25kV 650VSA N1 Threaded Stud 35kV 750VSA N1 600 Series Elbow 15/25kV 650SA N1 Threaded Stud 35kV 750SA N1 Assembly Tool ALL 600ATm N12 (Window-Op) Spanner Wrench ALL 600SW N9

Direct Voltage Test

ALL

Meter Adapter for: HDElectricMeters 200TC-� N14 RossMeters 200TC-2 N14 ChanceMeters 200TC-� N14

600 Series Deadbreak

N1. For 900 Amp ratings, substitute 675 for 650 and 655; 676 for 656; K671 for K651; K675 for K650 and K655; K676 for K656; 775 for 750 and 755; 776 for 756 and 2X for 0X in the part number. The 900 Amp rating requires copper current-carrying connector components and copper conductor cable.

N2.Addsuffixsymbolfrompage29toincludecableshieldgroundingkitand/or cable jacket sealing kit.

N3. Available without the stud by adding “N” to the part number. N4. Straight Receptacle Adapter is used to connect Straight Receptacles

K655YBSR and K655YSR-W0X (Pg.19) to equipment bushings. N5. Aluminum lug for use on aluminum or copper conductors. DO NOT

substitute threaded 03600X lug. N6. Copper lug for use on COPPER CONDUCTOR ONLY. DO NOT

substitute threaded 03602X lug. N7. Available with the stud factory-assembled by adding “SP” to the part

number. 675ETP, K675ETP and 775ETP are available as -SP only. Thestudisnotfieldremovable.

N8.Availablewithaloosestudbyaddingsuffix“S”tothepartnumber. N9. 600SW spanner wrench is recommended for installation of K650CP

connecting plug, deadbreak reducing tap plugs and reducing tap wells.

N10. Use 600ATM Assembly Tool.N11. 600 Series Elbows and Straight Receptacles with IEEE Std. 386

capacitive test points are available by substituting 656 for 655; K656 for K655; K676 for K675; 756 for 755; 676 for 675; K676 for K675 and 776 for 775 in the part number.

N12. See page 17 for Window-Op Connector Kit.N13. Superseded by K651CP.N14. Direct Test Connectors, along with a 200TC-X series meter adapter,

a properly rated voltage meter and Hot-line Stick; provides a means for direct conductor voltage testing.

N15. With stainless steel bracket.N16. Replacement Elbow includes an I-Adapter, and Straight Receptacle,

resulting in a net gain of 20”.

Refer to the W and X tables on pages 38 and 39 for sizing to cable insulation diameter and conductor size.For cable shield adapters and jacket seals, see page 28.

Page 3: CABLE ACCESSORIES - Border States Electric€¦ · PG-CA-0307 Use Tables W9 and X6 CAM-OP and

CABLE ACCESSORIESSe

para

ble

Con

nect

ors

600

Serie

s D

eadb

reak

�2 Thomas & Betts Corporation 8155 T&B Boulevard Memphis TN 38125 800.888.0211 www.tnb.com/utility PG-CA-0307

INTEGRAL BUSHING

RETAININGRING

CABLE TO EQUIPMENT

COMPRESSIONLUG

CABLEADAPTER

CABLE TO CABLE

STRAIGHT RECEPTACLEHOUSING

LOADBREAKELBOW

TAP PLUG

200A LOADBREAKSEE PAGES 4, & 5

200A DEADBREAKSEE PAGES 8 & 9

LINK-OPLINK CONNECTOR

SPANNER WRENCH

OPERATINGACCESSORIES

4 PT JUNCTION

3 PT JUNCTION

2 PT JUNCTION

(UTILIZING JUNCTIONS)

HOTSTICK OPERABLE 600 SERIESCONNECTORS - SEE PAGES 14 - 17

STICK-OP

LINK-OP

COMPRESSIONLUG

CABLEADAPTER

VAULTSTRETCHER

CONNECTOR

CABLE TO CABLE

L-1

UTILIZING L-KITS

L-2

ELBOW CONNECTOR

STICK-OPLOADBREAK REDUCING

TAP PLUG

BOLT &WASHERS

STRAIGHTRECEPTACLE ADAPTER

L-3

L-4

THREADEDSTUD

LINK-OPRETAINERSLEEVES

200A TAPS

INSULATINGPLUG

INSULATEDPARKING BUSHING

BUSHINGEXTENDER

THREADEDCOMPRESSION

LUG

600 SERIESELBOW

CABLEADAPTER

COMPRESSIONLUG

CONNECTINGPLUG

STRAIGHT RECEPTACLE

REDUCING TAPWELL

THREADEDSTUD VOLTAGE

DETECTIONCAP

INSULATED CAPWITH TEST POINT

GROUNDINGPLUG

DEADBREAKREDUCINGTAP PLUG600 SERIES

TAPS

CAM-OPRETAINERSLEEVES

CONNECTINGPLUG

VAULTSTRETCHER

BUSHINGEXTENDER

THREADEDSTUD

THREADEDSTUD

WINDOW-OPSEE PGS 16 &17

CAM-OPCABLE

ADAPTER

COMPRESSIONLUG

CAM-OPLINK CONNECTOR

SEE PGS 14 & 15

SEE PGS 14 & 15

SEE PGS 16 & 17VS2

VS3

VS4

VAULT STRETCHERSCABLE TO CABLE UTILIZING

600 Series deadbreak elbows, straight receptacles, junctions, vault stretchers and accessories are used to connect equipment and cable on primary feeder and network circuits. Designs accommodate large conduc-tors and feature bolted connections and deadfront modular construction for maximum reliability, perfor-mance and versatility.

DE-ENERGIzED connectors can be quickly and easily connected and disconnected using standard hand tools and equipment in accordance with accepted operating practices. Optional accessories allow visible ex-ternal separation, by-pass, isolation, dead-ending, grounding, and testing as well as adding taps, surge arrest-ers and circuit protection.

Hotstick operable and separable joint systems are shown on pages 14 thru 19.

rATinGS oVErViEWSee page 2 for complete information.

CUrrEnT rATinGS(Prefixes: 650, K650, K655, K656, 750, 755, 756 & 03700)600 Amp Continuous25kA sym., 10 cycles(Prefixes 675, K675, K676, 775, 776 & 03702)900 Amp Continuous25kA sym., 10 cyclesNOTE: 900 Amp ratings require copper cable and copper current-carrying components.

VoLTAGE rATinGS�5/25kV Class (5kV thru 28kV) 16.2kV Phase-to-Ground 28kV Phase-to-Phase 140kV BIL 45kV AC Withstand 84kV DC Withstand 21.5kV Corona Extinction35kV Class 21.1kV Phase-to-Ground 36.6kV Phase-to-Phase 150kV BIL 50kV AC Withstand 103kV DC Withstand 26kV Corona ExtinctionNote: Elastimold has increased the IEEE Standard Production and Design Test levels for 25kV Class products to include 27kV and 28kV systems.

SEE PRODUCT GUIDE PG-PC-E FOR

SURGE ARRESTERAPPLICATIONS

600 Series Deadbreak

SEPArABLE ConnECTorS 600 SEriES DEADBrEAK

Page 4: CABLE ACCESSORIES - Border States Electric€¦ · PG-CA-0307 Use Tables W9 and X6 CAM-OP and

Separable Connectors

600 Series Deadbreak

CABLE ACCESSORIES

�3Thomas & Betts Corporation 8155 T&B Boulevard Memphis TN 38125 800.888.0211 www.tnb.com/utilityPG-CA-0307

illustration Description Voltage ELASTimoLD notes (not to scale) Class Part number

2-Point Junction 15/25kV K650J2 N1,9,10 35kV 750J2 N1,9,10 3-Point Junction 15/25kV K650J3 N1,9,10 35kV 750J3 N1,9,10

4-Point Junction 15/25kV K650J� N1,9,10 35kV 750J� N1,9,10

1-way 15/25kV K655L� N1,2,3,4 L-Kit 35kV 755L� N1,2,3,4

2-way 15/25kV K655L2 N1,2,3,4,5,6,7 L-Kit 35kV 755L2 N1,2,3,4,5,6,7 2-way 15/25kV K655VSL2 N1,2,3 VS-Kit 35kV 755VSL2 N1,2,3 3-way 15/25kV K655L3 N1,2,3,4,5 L-Kit 35kV 755L3 N1,2,3,4,5 3-Way 15/25kV K655VSL3 N1,2,3,5,6,7 VS Kit 35kV 755VSL3 N1,2,3,5,6,7 4-Way 15/25kV K655L� N1,2,3,4,5 L-Kit 35kV 755L� N1,2,3,4,5

4-Way 15/25kV K655VSL� N1,2,3,5 VS-Kit 35kV 755VSL� N1,2,3,5 Assembly Tool ALL 600ATm N8 (Window-Op)

Spanner Wrench ALL 600SW N2

N1. For 900 Amp ratings, substitute 675 for 650 and 655; 676 for 656; K675 for K650 and K655; K676 for K656; 775 for 750 and 755; 776 for 756 and 2X for 0X in the part number. The 900 Amp rating requires copper current-carrying connector components and copper conductor cable.

N2. 600SW spanner wrench is recommended for installation of K650CP connecting plug, deadbreak reducing tap plugs and reducing tap wells.

N3. L-Kits and VS-Kits do not include cable adapters or compression lugs. These items must be ordered separately.

N4. 600 Series Elbows and Straight Receptacles with IEEE Std. 386 capacitive test points are available by substituting 656 for 655; K656 for K655; K676 for K675; 756 for 755; 676 for 675; K676 for K675 and 776 for 775 in the part number.

N5. 600ATM is recommended for installing K651CP and 750CP.N6. Can be used as a repair joint. (Gains 3-1/2” of repair length)N7. Can be used as a reducing joint for different size cables.N8. See page 17 for Window-Op Connector Kit.N9. Rubber junction with stainless steel mounting plate and back plate.

Add “-U” for rubber junction with stainless steel mounting plate, back plate and adjustable mounting bracket. Add “-4” for rubber junction only. Add “-5” for rubber junction, stainless steel U-straps and back plate.

N10. Two - six-position multi-point junctions shown on pages 20 and 21.

VAULT STrETCHEr

Provides an alternate method of splicing and joining various types and styles of cables using standard 600 Series components.

600 Series Deadbreak

Refer to the W and X tables on pages 38 and 39 for sizing to cable insulation diameter and conductor size.For cable shield adapters and jacket seals, see page 28.

Page 5: CABLE ACCESSORIES - Border States Electric€¦ · PG-CA-0307 Use Tables W9 and X6 CAM-OP and

CABLE ACCESSORIESSe

para

ble

Con

nect

ors

600 S

er. D

B (C

am-o

p, Lin

k-op)

�� Thomas & Betts Corporation 8155 T&B Boulevard Memphis TN 38125 800.888.0211 www.tnb.com/utility PG-CA-0307

Elastimold’s 600 Series Cam-Op™, and Link-Op™ deadbreak connec-tor systems incorporate provisions for hotstick operation of DE-ENERGIzED primary feeder or network circuits. Configurations allow external visible break, testing, grounding and isolation. Retrofit kits allow upgrading exist-ing equipment.

Cam-Op systems utilize pin and socket connectors. Link-Op con-nectors are bolted and installed using torque controlled tools. Either system can be retrofitted to existing equipment.

The Cam-Op and Link-Op connec-tors are unique, allowing all hot-stick operations to be completed without moving the cable, an im-portant consideration when large, stiff cables prohibit movement.

The Cam-Op connector is easily installed or removed by hotstick operation of the cam action disconnect lever.

LOADBREAKELBOW CONNECTOR

INSULATEDCAP ELBOW

ARRESTER

LINKCONNECTOR

LINK-OP

LINK-OP

CAM-OP

CAM-OP

RETAINERSLEEVES

OR2-POINT INSULATED

BUSHINGS

OR

OROR

OR

OR

OR

600 SERIESELBOW

600 SERIESELBOW

COMPRESSIONLUG

COMPRESSIONLUG

SEECABLENOTES

SEECABLENOTES

CABLEADAPTER

600 SERIESELBOW

COMPRESSIONLUG

SEE CABLE NOTES

CABLEADAPTER

CABLEADAPTER

LOADBREAKELBOW CONNECTOR

INSULATEDCAP

ELBOWARRESTER

LINK CONNECTOR

BUSINGEXTENDER

ALIGNMENTBRACKET

ALIGNMENTBRACKET

LINK-OP

CAM-OP

LINK-OPLINK-OP

CAM-OPCAM-OP

RETAINERSLEEVES

INSULATEDPARKINGBUSHING

EQUIPMENTBUSHING

EQUIPMENTBUSHING

MOUNTABLE INSULATEDPARKING BUSHING

OR

LINK-OP

CAM-OP

LOADBREEAKREDUCING TAP PLUG

OPERATING TOOL

TEST ROD

GROUNDINGELBOW

RETROFIT COMPONENTS FOREXISTING EQUIPMENT W/O PROVISIONS FOR MOUNTABLE INSULATED BUSHING

CABLE TO EQUIPMENT

CABLE TO CABLE CONNECTION

rATinGS oVErViEWSee page 2 for complete information.CUrrEnT rATinGS600 & 900 Amp Continuous25kA sym., 10 cycles

NOTE: 900 Amp ratings require copper cable and copper current-carrying components.

ConTinUoUS VoLTAGE rATinGS�5kV Class 8.3kV Phase-to-Ground 14.4kV Phase-to-Phase 95kV BIL 34kV AC Withstand 53kV DC Withstand 11kV Corona Extinction25kV Class 15.2kV Phase-to-Ground 26.3kV Phase-to-Phase 125kV BIL 40kV AC Withstand 78kV DC Withstand 19kV Corona Extinction35kV Class 21.1kV Phase-to-Ground 36.6kV Phase-to-Phase 150kV BIL 50kV AC Withstand 103kV DC Withstand 26kV Corona Extinction

SEE PRODUCT GUIDE PG-PC-E FOR

SURGE ARRESTERAPPLICATIONS

CAm-oP™ & LinK-oP™ SYSTEm – 600 SEriES DEADBrEAK

600 Series Deadbreak – Cam-Op™, Link-Op™

Page 6: CABLE ACCESSORIES - Border States Electric€¦ · PG-CA-0307 Use Tables W9 and X6 CAM-OP and

Separable Connectors

600 Ser. DB (Cam-op, Link-op)CABLE ACCESSORIES

�5Thomas & Betts Corporation 8155 T&B Boulevard Memphis TN 38125 800.888.0211 www.tnb.com/utilityPG-CA-0307

illustration Description Voltage ELASTimoLD notes (not to scale) Class Part number

CAM-OP 15kV 655LinK-C-Lr-W0X-B-DrG N1,3,11, CONNECTOR Use Tables W7 and X6 13,14,18 KIT 25kV K655LinK-C-Lr-W0X-B-DrG N1,3,11, Use Tables W7 and X6 13,14,18 35kV 755LinK-C-Lr-W0X-B-DrG N1,3,11, Use Tables W9 and X6 13,14,18 LINK-OP 15kV 655LinK-B-Lr-W0X-B-DrG N2,3,11,12 CONNECTOR Use Tables W7 and X6 13,14,18 KIT 25kV K655LinK-B-Lr-W0X-B-DrG N2,3,11, Use Tables W7 and X6 13,14,18 35kV 755LinK-B-Lr-W0X-B-DrG N2,3,11, Use Tables W9 and X6 13,14,18 Mountable 25kV K650LBm-3 N3 Insulated 35kV 750LBm-3 N3 Bushing RETROFIT 15kV 655LinK-C-Lr-W0X-A-DrG N5,11,13 CAM-OP Use Tables W7 and X6 14,18 CONNECTOR 25kV K655LinK-C-Lr-W0X-A-DrG N5,11,13 KIT Use Tables W7 and X6 14,18 35kV 755LinK-C-Lr-W0X-A-DrG N5,11,13 Use Tables W9 and X6 14,18 RETROFIT 15kV 655LinK-B-Lr-W0X-A-DrG N6,11,12, LINK-OP Use Tables W7 and X6 13,14,18 CONNECTOR 25kV K655LinK-B-Lr-W0X-A-DrG N6,11,12, KIT Use Tables W7 and X6 13,14,18 35kV 755LinK-B-Lr-W0X-A-DrG N6,11,12, Use Tables W9 and X6 13,14,18 Insulating 25kV K650LB N4 Plug 35kV 750LB N4 CAM-OP 15kV 650CAB Alignment 25kV K650CAB Bracket 35kV 750CAB LINK-OP ALL 650AB N15 Alignment ALL 650ABV N15 Bracket(Retrofit LINK-OP Only) Compression ALL 03700X N7 Lug Use Table X6 N8 ALL 03702X Use Table X6

CAM-OP & 15/25kV 655CK-W0X N13 LINK-OP Size Use Tables W7 and X6 Sensitive Kit 35kV 755CK-W0X N13 (Cable Adapter Use Tables W9 and X6 & Lug) CAM-OP Re- ALL 650rSC N11 taining Sleeve LINK-OP ALL 650rS N11 Retaining Sleeve

CAM-OP 15kV 655Bi-LinK-C-Lr-WoX-DrG N9,11,13 CABLE JOINT Use Tables W7 and X6 14,18 KIT 25kV K655Bi-LinK-C-Lr-WoX-DrG N9,11,13 Use Tables W7 and X6 14,18 35kV 755Bi-LinK-C-Lr-WoX-DrG N9,11,13 Use Tables W9 and X6 14,18

LINK-OP 15kV 655Bi-LinK-B-Lr-WoX-DrG N10,11,12, CABLE JOINT Use Tables W7 and X6 13,14,18 KIT 25kV K655Bi-LinK-B-Lr-WoX-DrG N10,11,12, Use Tables W7 and X6 13,14,18 35kV 755Bi-LinK-B-Lr-WoX-DrG N10,11,12, Use Tables W9 and X6 13,14,18 CAM-OP 15kV 650LK-C-VB Loadbreak 25kV K650LK-C-VB Reducing 35kV 750LK-C-VB Tap Plugs (Visi-Break) LINK-OP 15kV 650LT-B N11 Loadbreak 25kV K650LT-B Reducing 35kV 750LT-B Tap Plug

illustration Description Voltage ELASTimoLD notes (not to scale) Class Part number

Grounding 15kV �60GLr Elbow 25kV 370GLr N19 (1/0 AWG x 6’ 35kV 370GLr N19 Ground Lead)

Test Rod ALL 370Tr

Assembly Tool ALL 600AT N11

CAM-OP 15kV 650CAm-oK N16 OPERATING 25kV K650CAm-oK N16 KIT 35kV 750CAm-oK N16

LINK-OP 15kV 650LinK-oK N17 OPERATING 25kV K650LinK-oK N17 KIT 35kV 750LinK-oK N17

AB ABV

N1. Cam-Op connector kit includes: 1- Cam-Op link; 1- elbow housing; 1- cable adapter; 1-0370 style lug; 1- bushing extender; 2- retainer sleeves; 1- insulated cap; 1- mountable insulated bushing and 1- alignment bracket.

N2. Link-Op connector kit includes: 1- Link-Op link; 1- elbow housing; 1- cable adapter; 1-0370 style lug; 1- bushing extender; 2- retainer sleeves; 2- insulated caps; and 1- mountable insulated bushing.

N3. Mountable insulated bushing included with Cam-Op and Link-Op connector kit. Requires 3 threaded studs on equipment faceplate for installation.

N4. UsewiththeRetrofitCam-OpandRetrofitLink-Opconnectorkit. N5. RetrofitCam-Opconnectorkitincludes:1-link;1-elbowhousing;

1- cable adapter; 1-0370 style lug; 1- bushing extender; 2- retainer sleeves; 1- insulated cap; 1- insulating plug; and 1- alignment bracket.

N6. RetrofitLink-Opconnectorkitincludes:1-link;1-elbowhousing;1- cable adapter; 1-0370 style lug; 1- bushing extender; 2- retainer sleeves; 2- insulated caps; 1- insulating plug; and 1- alignment bracket.

N7. Aluminum lug for use on aluminum or copper conductors. DO NOT substitute threaded 03600X lug.

N8. Copper lug for use on COPPER CONDUCTOR ONLY. DO NOT sub-stitute 03602X threaded lug.

N9. Cam-Op Cable Joint Kit includes: 1- Cam-Op link; 1- Cam-Op BI-SOP; 2- elbow housings; 2- cable adapters; 2- 0370 style lugs; 2- re-tainer sleeves; 1- insulated cap.

N10. Link-Op Cable Joint Kit includes: 1- Link-Op link; 1- Link-Op BI-SOP; 2- elbow housings; 2- cable adapters; 2- 0370 style lugs; 2- retainer sleeves; 2- insulated caps.

N11. 600AT assembly tool required for operation and/or installation of Link-Op. 600ATM is recommended for installing Link-Op/Cam-Op retaining sleeves.

N12. For 900 Amp ratings, substitute 675 for 650 and 655; 676 for 656; K675 for K650 and K655; K676 for K656; 775 for 750 and 755; 776 for 756 and 2X for 0X in the part number. The 900 Amp rating requires copper current-carrying connector components and copper conductor cable.

N13. Addsuffixsymbolfrompage29toincludecableshieldgroundingkitand/or cable jacket sealing kit.

N14. To add elbows or arresters instead of insulating caps, replace the “DRG” with “LR-WX” for elbows (with test point) or “ESA” for elbow arresters.

N15. The 650ABV is required when the bushing horizontal spacing on the equipment or junctions is less than 5”.

N16. Cam-Op operating kit includes accessories that enable visible break, testing, isolation and grounding functions to be performed. Kit includes: 3- Cam-Op loadbreak reducing tap plugs; 3- grounding elbows; 1- assembly tool; 1- test rod; 1- carry case; 1- lubricant; 1- instructions.

N17. Link-Op operating kit includes accessories that enable visible break, testing, isolation and grounding functions to be performed. Kit includes: 6- Link-Op loadbreak reducing tap plugs; 3- grounding elbows; 1- assembly tool; 1- test rod; 1- carry case; 1- lubricant; 1- instructions.

N18. 600 Series Elbows and Straight Receptacles with IEEE Std. 386 ca-pacitive test points are available by substituting 656 for 655; K656 for K655; K676 for K675; 756 for 755; 676 for 675; K676 for K675 and 776 for 775 in the part number.

N19. Rated for both 25kV and 35kV applications.

600 Series Deadbreak – Cam-Op™, Link-Op™

Refer to the W and X tables on pages 38 and 39 for sizing to cable insulation diameter and conductor size.For cable shield adapters and jacket seals, see page 28.

Page 7: CABLE ACCESSORIES - Border States Electric€¦ · PG-CA-0307 Use Tables W9 and X6 CAM-OP and

CABLE ACCESSORIESSe

para

ble

Con

nect

ors

600 S

er. DB

(Stic

k-op,

Wind

ow-o

p)

�6 Thomas & Betts Corporation 8155 T&B Boulevard Memphis TN 38125 800.888.0211 www.tnb.com/utility PG-CA-0307

Elastimold’s 600 Series Window-Op™ and Stick-Op™ deadbreak connector systems incorporate provisions for hotstick opera-tion of DE-ENERGIzED primary feeder or network circuits.

The Window-Op and Stick-Op connectors allow direct testing and grounding with no required cable movement.

Window-Op is ideal for equip-ment applications which include viewing windows to provide an internal visible break that does not require hotstick removal of the elbows.

Stick-Op provides an external vis-ible break by hotstick removal of the elbow.

Window-Op and Stick-Op con-nectors are bolted and installed using torque controlled tools.

BOLTED CONNECTIONLOADBREAK REDUCINGTAP PLUG

INSULATEDCAP

STICK-OPERABLE

rATinGS oVErViEWSee page 2 for complete information.CUrrEnT rATinGS600 & 900 Amp Continuous25kA sym., 10 cycles

NOTE: 900 Amp ratings require copper cable and copper current-carrying components.

ConTinUoUS VoLTAGE rATinGS�5kV Class 8.3kV Phase-to-Ground 14.4kV Phase-to-Phase 95kV BIL 34kV AC Withstand 53kV DC Withstand 11kV Corona Extinction25kV Class 15.2kV Phase-to-Ground 26.3kV Phase-to-Phase 125kV BIL 40kV AC Withstand 78kV DC Withstand 19kV Corona Extinction35kV Class 21.1kV Phase-to-Ground 36.6kV Phase-to-Phase 150kV BIL 50kV AC Withstand 103kV DC Withstand 26kV Corona Extinction

600 SERIESELBOW

CABLE ADAPTER

TEST ROD

OPERATING ACCESSORIES

INTEGRALBUSHING

ASSEMBLY TOOL(STICK-OP)

ASSEMBLY TOOL(WINDOW-OP)

GROUNDINGELBOW

STAND-OFFPLUG

SEE CABLE NOTES

STICK-OP LRTPLOADBREAK

TAP PLUG

STICK-OP600DB/200LB

BUSHING/ELBOWADAPTER

THREADEDCOMPRESSION LUG

STICK-OP

GROUNDINGPLUG

INSULATED CAP

WINDOW-OP ETPELBOW TAP PLUG

COMPRESSION LUGWINDOW-OP

OR

SEE PRODUCT GUIDE PG-PC-E FOR

SURGE ARRESTERAPPLICATIONS

600 Series Deadbreak – Stick-Op™, Window-Op™

STiCK-oP™ & WinDoW-oP™ SYSTEm – 600 SEriES DEADBrEAK

Page 8: CABLE ACCESSORIES - Border States Electric€¦ · PG-CA-0307 Use Tables W9 and X6 CAM-OP and

Separable Connectors

600 Ser. DB (Stick-op, Window-op)CABLE ACCESSORIES

�7Thomas & Betts Corporation 8155 T&B Boulevard Memphis TN 38125 800.888.0211 www.tnb.com/utilityPG-CA-0307

illustration Description Voltage ELASTimoLD notes (not to scale) Class Part number

WINDOW-OP 15kV 655ETP-W0X-DrG N1,4,5,6 Connector Kit Use Tables W7 and X6 13,15 25kV K655ETP-W0X-DrG Use Tables W7 and X6 35kV 755ETP-W0X-DrG Use Tables W9 and X6

WINDOW-OP 15kV 655rETP N4,5,6 Replacement 13,15,16 Connector Kit 25kV K655rETP STICK-OP 15kV 655LrTP-W0X-DrG N2,3,4,5, Connector Kit Use Tables W7 and X6 8,13 25kV K655LrTP-W0X-DrG Use Tables W7 and X6 35kV 755LrTP-W0X-DrG Use Tables W9 and X6 STICK-OP 15kV 655rLrTP N3,4,5 Replacement 8,13,16 Connector Kit 25kV K655rLrTP WINDOW-OP 15kV 650ETP N4,15 Loadbreak 25kV K650ETP N4,15 Elbow 35kV 750ETP N4,15 Tap Plug STICK-OP 15kV 650LrTPA3 N3,4 Loadbreak 25kV K650LrTPA2 Reducing 35kV 750LrTPA2 Tap Plug STICK-OP 15kV 650BEA3 N3,4 Bushing 25kV K650BEA2 Adapter 35kV 750BEA2 Compression ALL 03700X N6 Lug Use Tables X6 WINDOW-OP ALL 03702X N7 Use Tables X6

Threaded ALL 03600X N8 Compression Use Tables X6 Lug ALL 03602X N9 STICK-OP Use Tables X6

WINDOW-OP 15/25kV 655CK-W0X N5 Size Sensitive Kit Use Tables W7 and X6 (Cable Adapter 35kV 755CK-W0X N5 & Lug) Use Tables W9 and X6

STICK-OP 15/25kV 655TCK-W0X N5 Size Sensitive Kit Use Tables W7 and X6 (Cable Adapter 35kV 755TCK-W0X N5 & Threaded Lug) Use Tables W9 and X6

Extraction Tool ALL 650ET N10

Grounding 15kV �60GLr Elbow 25kV 370GLr N14 (1/0 AWG x 6’ 35kV 370GLr N14 Ground Lead)

Test Rod ALL 370Tr

Assembly Tool ALL 600AT N3 (Stick-Op) Assembly Tool ALL 600ATm N15 (Window-Op) STICK-OP 15kV 650STiCK-oK N11 OPERATING 25kV K650STiCK-oK N11 KIT 35kV 750STiCK-oK N11 WINDOW-OP 15kV 650WinDoW-oK N12 OPERATING 25kV K650WinDoW-oK N12 KIT 35kV 750WinDoW-oK N12

N1. Window-Op Kit includes: insulated cap; Window-Op reducing tap plug; 600 Series elbow housing; cable adapter; and 0370 style compression lug.

N2. Stick-Op Kit includes insulated cap; Stick-Op Loadbreak reducing tap plug; 600A Elbow Housing; cable adapter; and threaded 0360 style compression lug.

N3. 600AT assembly tool required for operation and/or installation of Stick-Op.

N4. For 900 Amp ratings, substitute 675 for 650 and 655; 676 for 656; K675 for K650 and K655; K676 for K656; 775 for 750 and 755; 776 for 756 and 2X for 0X in the part number. The 900 Amp rating requires copper current-carrying connector components and copper conductor cable.

N5. Addsuffixsymbolfrompage29toincludecableshieldgrounding kit and/or cable jacket sealing kit.

N6. Aluminum lug for use on aluminum or copper conductors. DO NOT substitute threaded 03600X lug.

N7. Copper lug for use on COPPER CONDUCTOR ONLY. DO NOT substitute 03602X threaded lug.

N8. Threaded aluminum lug (Stick-Op only) for use on copper or aluminum conductors. DO NOT substitute unthreaded 03700X lugs. DO NOT use with 675, 676, K675, K676, 775 or 776 part numbers.

N9. Threaded copper lug (Stick-Op only) for use on copper conductors only. DO NOT substitute unthreaded 03702X lugs.

N10. Required to disassemble Stick-Op loadbreak reducing tap plug from the threaded compression lug and 600 Series elbow after the shear-pin is broken during assembly.

N11. Stick-Op Operating Kit includes accessories that enable visible break direct testing, isolation, and grounding functions to be performed. Kit includes: 3-insulated parking bushings; 3-grounding elbows; 3-600DB/200LB bushing/elbow adapters; 1-assembly tool; 1-test rod; 1-carry case; 1-lubricant; 1-instructions.

N12. Window-Op Operating Kit includes accessories that enable visible grounding and direct testing functions to be performed. Kit includes: 3-grounding elbows; 1-test rod; 1-carry case; 1-lubricant; 1-instructions.

N13. 600 Series Elbows and Straight Receptacles with IEEE Std. 386 capacitive test points are available by substituting 656 for 655; K656 for K655; K676 for K675; 756 for 755; 676 for 675; K676 for K675 and 776 for 775 in the part number.

N14. Rated for both 25kV and 35kV applications. N15. 600ATM assembly tool required for Window-Op assembly.

50 – 60 ft/lbs torque wrench required but not included.N16. Replacement Elbow includes: insulated cap; reducing tap plug; 600 series elbow housing; I-Adapter; straight receptacle, resulting in a net gain of 20” in length vs. a standard elbow kit. Compression lugs and cable adapters are ordered separately.

600 Series Deadbreak – Stick-Op™, Window-Op™

Refer to the W and X tables on pages 38 and 39 for sizing to cable insulation diameter and conductor size.For cable shield adapters and jacket seals, see page 28.

Page 9: CABLE ACCESSORIES - Border States Electric€¦ · PG-CA-0307 Use Tables W9 and X6 CAM-OP and

CABLE ACCESSORIESSh

ield

Ada

pter

s, G

roun

d-in

g Ki

ts a

nd J

acke

t Sea

ls

28 Thomas & Betts Corporation 8155 T&B Boulevard Memphis TN 38125 800.888.0211 www.tnb.com/utility PG-CA-0307

�0TL 20 mA 2�mA

CONCENTRICNEUTRAL

CABLE

JACKETEDCONCENTRIC

NEUTRALCABLE

DRAINWIRE

SHIELDEDCABLE

COPPERTAPE

SHIELDEDCABLE

LEADJACKETED

CABLE

UNISHIELDCABLE

600/200ECS

600/200ECSG1-2

600/200ECSG2-2

600/200ECSG3

NONEREQUIRED

21MA 20MA 10TL 10TL

CONDUCTOR

INSULATION

EXTRUDED SHIELD

CONCENTRIC NEUTRAL WIRES

OUTER JACKET

CONDUCTOR

INSULATION

EXTRUDED SHIELD

DRAIN WIRES

OUTER JACKET

CONDUCTOR

INSULATION

EXTRUDED SHIELD

COPPER SHIELD

OUTER JACKET

CONDUCTOR

INSULATION

EXTRUDED SHIELD

OUTER JACKET

CONDUCTOR

INSULATION

EXTRUDED CONDUCTIVE JACKET

DRAIN WIRES

CONDUCTOR

INSULATION

EXTRUDED SHIELD

CONCENTRIC NEUTRAL WIRES

CABLE ENTRANCE DETAIL

INSULATIONEPDM RUBBER

MOLDED SHIELDCONDUCTIVE EPDM RUBBER

CABLESHIELDTYPES

ECS

CABLE SHiELD ADAPTErS Cable �0TL 20mA 2�mA insulation Dia. inches inches inches

min. 0.495 0.530 0.530 max. 1.875 1.780 1.780

JACKET SEALS Jacket 200ECS 600ECS o.D. inches inches

min. 0.80 1.28 max. 1.50 2.30

Elastimold elbows, cable joints and terminators have been designed for use on XLP, EPR or similar solid dielectric insulated power cables. These cables are available with a variety of optional shielding and jacket constructions. In order to properly mate and install the cable to an Elastimold product, the use of a shield adaptor, grounding kit or jacket seal may be required. The diagram below provides informa-tion concerning the application and selection of various shield adap-tors, grounding kits and jacket seals for the most popular cable types. Consult the factory for recommendations concerning other cable con-structions.

Shield Adapters, Sealing & Grounding

Page 10: CABLE ACCESSORIES - Border States Electric€¦ · PG-CA-0307 Use Tables W9 and X6 CAM-OP and

Shield Adapters, Ground-

ing Kits and Jacket SealsCABLE ACCESSORIES

29Thomas & Betts Corporation 8155 T&B Boulevard Memphis TN 38125 800.888.0211 www.tnb.com/utilityPG-CA-0307

Illustration Description ELASTIMOLD Suffix Notes (not to scale) Part number

Cold Shrinkable 200ECS -S N1,3 Jacket Seal

Cold Shrinkable 600ECS -S N1,4 Jacket Seal

Metallic Tape 20mA-W -0mA N1,2,5,6 Shield Adapter Use Table W14 for sizing Wire Shield 2�mA-W -�mA N1,2,5,6 Adapter Use Table W14 for sizing Shield �0TL-W -TL N1,2 Adapter Use Table W15 for sizing Cold Shrinkable Seal 200ECSG�-2 -SG� N1,3,5,6 w/ Copper Rod & Crimp Connector Cold Shrinkable Seal 600ECSG�-2 -SG� N1,4,5,6 w/ Copper Rod & Crimp Connector Cold Shrinkable Seal 200ECSG2-2 -SG2 N1,3,5,6 w/ Copper Rod & Constant Force Spring Cold Shrinkable Seal 600ECSG2-2 -SG2 N1,4,5,6 w/ Copper Rod & Constant Force Spring Cold Shrinkable Seal 200ECSG3 -SG3 N1,3,5,7 w/ Copper Braid & Constant Force Spring Cold Shrinkable Seal 600ECSG3 -SG3 N1,4,5,7 w/ Copper Braid & Constant Force Spring

N1. To order the kits as separate items, use the part numbers shown in the table. Example: To order a cold shrinkable tube as a separate item, use the part number 200ECS.

Toorderthekitsascomponentsofotheritems,addthesuffixtotheend of the part number. Example: To order a cold shrinkable jacket seal as a component of an elbow kit, use the part number 166LR-A5200-S.

N2. Onlyusethissuffixwithpartnumbersthatdesignatea“W”housingsize.Sizingthemaincomponentwillalsosizethesuffixadapter.

N3. Size range .80” to 1.50” jacket diameters. Maximum installed diameter is approx. 2”.

N4. Size range 1.28” to 2.30” jacket diameters. Maximum installed diameter is approx. 2.75”.

N5. Voltage rating equal to Elastimold product being used.N6. Copper rod size is no. 6 for sizes FA thru HA and no. 2 for sizes

HAB thru JB.N7. Braid is equivalent to no. 6 copper rod for sizes FA thru HA and no.

2 copper rod for sizes HAB thru JB.

insulation Table W�5 inches Symbol min. mAX. for W .495 .585 EB .525 .635 EF .575 .585 FA .625 .735 FAB .675 .785 FB .725 .835 FG .775 .885 GA .825 .935 GAB .875 .985 GB .930 1.040 GH .980 1.115 HA 1.040 1.175 HAB 1.095 1.240 HB 1.160 1.305 HJ 1.220 1.375 JA 1.285 1.395 JAB 1.355 1.520 JB 1.485 1.595 KA 1.530 1.640 KAB 1.575 1.685 KB 1.755 1.875 PB

USE for�0TL

insulation Table W�� inches Symbol min. mAX. for W .530 .680 E .640 .820 F .760 .950 G .850 1.050 H .980 1.180 J 1.090 1.310 K 1.180 1.465 L 1.370 1.630 M 1.515 1.780 N

USE for20mA2�mA

Shield Adapters, Sealing & Grounding

Page 11: CABLE ACCESSORIES - Border States Electric€¦ · PG-CA-0307 Use Tables W9 and X6 CAM-OP and

CABLE ACCESSORIESr

efer

ence

32 Thomas & Betts Corporation 8155 T&B Boulevard Memphis TN 38125 800.888.0211 www.tnb.com/utility PG-CA-0307

How to Specify Size-Sensitive Products

inSULATion DiAmETEr SELECTion GUiDEElastimold Elbows, cable joints and terminations are designed for application on XLP, EPR and other solid dielectric insulated power cables. These components are constructed of molded elas-tomerandrelyonaninterferencefitwiththecableinsulationdiameterinordertomaintainproperdielectric strength, creep path integrity and a water seal. Elastimold components are available in a wide range of sizes in order to accommodate a variety of cable insulation diameters.Selection of size-sensitive components requires determining the cable insulation diameter. This can be done in several ways:A. Refer to the cable manufacturer’s spec sheet for dimensions.B. Measure the cable.C. If the cable conforms to AEIC or ICEA standards and is:

1. 15kV, 175 mil wall thickness, use the table on page 34.2. 15kV, 220 mil wall thickness, use the table on page 35.3. 25kV, 260 mil wall thickness, use the table on page 35.4. 35kV, 345 mil wall thickness, use the table on page 36.

After the cable insulation diameter minimum and maximum has been determined:1. Locate the W table indicated in the part number selection chart.2. Complete the ordering information by selecting and inserting the symbol (given in the

W table) into the part number.

‘W’INSULATIONDIAMETER

Determines Size of Molded Rubber Part

‘W’CABLE

INSULATIONDIAMETER

orDErinG EXAmPLESAEiC

To complete the information required to order a K655LR-W0X elbow for use on standard AEIC 1000 kcmil com-pressed stranding aluminum 25kV cable with .260 inch thick insulation wall:

A. Determine that the insulation diameter (for AEIC cable in the table on pages 34-36) is 1.645 – 1.770 inches.

B. For this elbow, the part number selection chart on page 11 indicates to use table W7 for elbow sizing and table X6 for connector sizing.

C. From table W7 the symbol for W is n.

D. From table X6 the symbol for X is ��0.

E. The completed part number therefore is K655LR-n0��0.

iCEATo complete the information required to order a K655LR-W0X elbow for use on standard ICEA 1000 kcmil com-pressed stranding aluminum 25kV cable with .260 inch thick insulation wall:

A. Determine that the insulation diameter (for ICEA cable in the table on pages 34-36) is 1.645 – 1.740 inches.

B. For this elbow, the part number selection chart on page 11 indicates to use table W7 for elbow sizing and table X6 for connector sizing.

C. From table W7 the symbol for W is n.

D. From table X6 the symbol for X is ��0.

E. The completed part number therefore is K655LR-n0��0.

Page 12: CABLE ACCESSORIES - Border States Electric€¦ · PG-CA-0307 Use Tables W9 and X6 CAM-OP and

CABLE ACCESSORIESr

eference

33Thomas & Betts Corporation 8155 T&B Boulevard Memphis TN 38125 800.888.0211 www.tnb.com/utilityPG-CA-0307

How to Specify Size-Sensitive Products

‘X’CABLE

CONDUCTOR

Determines Crimp Connector Size‘X’

CABLECONDUCTOR

‘Suffix’

Determines Required Accessories (if any)

• Cable Shield Adaptors• Cable Grounding Kits• Cable Jacket Seal

reference Pages 28 & 29 for application, selection and

ordering information.

ConnECTor SELECTion GUiDEElastimold elbows, cable joints and terminations are fur-nished with crimp style cable connectors. As standard, these connectors are constructed with a tin-plated aluminum barrel filled with an oxide inhibitor. Most aluminum barrel connec-tors are universal and are designed for use on either alumi-num or copper conductor cable.

When specified, all copper crimp style connectors can be fur-nished. These connectors are ONLy for use on copper conduc-tor cable and are not for use with aluminum conductor cables. Bi-metallic connectors are constructed with a copper top and an aluminum barrel. Bi-metal connectors can be used on either alu-minum or copper conductor cable and are furnished as standard with 200 Amp Loadbreak Elbows, 200 Amp Deadbreak Elbows, and PCT, 16 THG or MTG terminators with rod connectors.

Aluminum connectors used in PCJ Cable Joints are rated as follows:

• Aluminum conductor to aluminum conductor, cable rated

• Aluminum conductor to copper conductor, cable rated equal to the aluminum cable

Copper connectors used in PCJ Cable Joints are rated as follows:

• Copper conductor to copper conductor, cable rated

Selection and ordering the proper crimp connector requires determining information relative to the cable conductor as follows:

A. Conductor size in AWG or kcmil B. Conductor type (stranded, compressed, compact or solid) C. Conductor material (aluminum or copper)

After the cable conductor information has been determined: 1. Locate the X table indicated in the part number selection chart. 2. Complete the ordering information by selecting and insert-

ing the symbol (given in the X table) into the part number.

See the Ordering Example on page 32 for further information.

CABLE SHIELDAND JACKET

Page 13: CABLE ACCESSORIES - Border States Electric€¦ · PG-CA-0307 Use Tables W9 and X6 CAM-OP and

CABLE ACCESSORIESr

efer

ence

3� Thomas & Betts Corporation 8155 T&B Boulevard Memphis TN 38125 800.888.0211 www.tnb.com/utility PG-CA-0307

AEIC & ICEA Cable Insulation Diameter

�5kV Cable (�00% level, �75 mil)Aluminum & Copper Conductor

Sizeindustry Standard

Solid Conductor Stranded Conductor Compressed Conductor Compact ConductorDiameterinInchesover insulation

DiameterinInchesover insulation

DiameterinInchesover insulation

DiameterinInchesover insulation

min. Max. min. Max. min. Max. min. Max.

#2AEIC 0.610 0.700 – – 0.635 0.725 0.620 0.710ICEA 0.610 0.695 0.645 0.730 0.635 0.720 0.620 0.705

#�AEIC 0.645 0.730 – – 0.675 0.765 0.655 0.740ICEA 0.645 0.725 0.685 0.770 0.675 0.760 0.655 0.735

�/0AEIC 0.680 0.770 – – 0.715 0.805 0.690 0.775ICEA 0.680 0.760 0.725 0.810 0.715 0.800 0.690 0.775

2/0AEIC – – – – 0.760 0.850 0.730 0.815ICEA – – 0.775 0.855 0.760 0.845 0.730 0.815

3/0AEIC – – – – 0.810 0.900 0.775 0.865ICEA – – 0.825 0.905 0.810 0.895 0.775 0.860

�/0AEIC – – – – 0.865 0.955 0.830 0.915ICEA – – 0.880 0.965 0.865 0.950 0.830 0.910

250AEIC – – – – – – – –ICEA – – 0.935 1.020 0.920 1.005 0.880 0.965

350AEIC – – – – 1.025 1.115 0.980 1.065ICEA – – 1.045 1.130 1.025 1.110 0.980 1.065

500AEIC – – – – 1.150 1.245 1.100 1.185ICEA – – 1.175 1.260 1.150 1.235 1.100 1.185

750AEIC – – – – 1.340 1.440 1.280 1.370ICEA – – 1.370 1.455 1.340 1.425 1.280 1.365

�000AEIC – – – – 1.485 1.590 1.430 1.520ICEA – – 1.520 1.610 1.485 1.575 1.430 1.515

W = insulation Diameter (Conductor + 2 X Conductor Shield + 2 X wall)

ICEANOTE:DiametersspecifiedintheabovetablearedifferentthanspecifiedbyAEICCS8-00.ConsultAccessoryManufac-turer for proper selection of accessories. Diameters to be measured in accordance with 9.6.

AEiC CS8-06 SpecificationforExtrudedDielectric,

Shielded Power Cable Rated 5 - 46kV

AEIC-Calulated Diameters - Solid and Compressed Stranding from Tables C-4 & C-6 and Compact Stranding from Tables C-5 & C-7

AnSi/iCEA S-9�-6�9-200� & S-97-682-2000 Standard for Concentric Neutral Cables &

Utility Shielded Power Cables Rated 5 - 46kV ICEA-Concentric Stranding Table C-3, Compressed Stranding

Table C-4, Compact Stranding Table C-5

ICEAAbbreviated,foradditionalcablespleaserefertothestandard.

15kV 100% – 175 mil Insulation (.175”)15kV 133% – 220 mil Insulation (.220”)25kV 100% – 260 mil Insulation (.260”)35kV 100% – 345 mil Insulation (.345”)

WALL

Page 14: CABLE ACCESSORIES - Border States Electric€¦ · PG-CA-0307 Use Tables W9 and X6 CAM-OP and

CABLE ACCESSORIESr

eference

35Thomas & Betts Corporation 8155 T&B Boulevard Memphis TN 38125 800.888.0211 www.tnb.com/utilityPG-CA-0307

AEIC & ICEA Cable Insulation Diameter

�5kV Cable (�33% level, 220 mil)Aluminum & Copper Conductor

Sizeindustry Standard

Solid Conductor Stranded Conductor Compressed Conductor Compact ConductorDiameterinInchesover insulation

DiameterinInchesover insulation

DiameterinInchesover insulation

DiameterinInchesover insulation

min. Max. min. Max. min. Max. min. Max.

#2AEIC 0.700 0.790 – – 0.725 0.815 0.710 0.800ICEA 0.700 0.790 0.735 0.825 0.725 0.815 0.710 0.800

#�AEIC 0.735 0.820 – – 0.765 0.855 0.745 0.830ICEA 0.735 0.820 0.775 0.865 0.765 0.855 0.745 0.830

�/0AEIC 0.770 0.860 – – 0.805 0.895 0.780 0.865ICEA 0.770 0.855 0.815 0.905 0.805 0.895 0.780 0.865

2/0AEIC – – – – 0.850 0.940 0.820 0.905ICEA – – 0.865 0.950 0.850 0.935 0.820 0.905

3/0AEIC – – – – 0.900 0.990 0.865 0.955ICEA – – 0.915 1.000 0.900 0.985 0.865 0.955

�/0AEIC – – – – 0.955 1.045 0.920 1.005ICEA – – 0.970 1.060 0.955 1.045 0.920 1.005

250AEIC – – – – – – – –ICEA – – 1.025 1.115 1.010 1.100 0.970 1.060

350AEIC – – – – 1.115 1.205 1.070 1.155ICEA – – 1.135 1.220 1.115 1.200 1.070 1.155

500AEIC – – – – 1.240 1.335 1.190 1.275ICEA – – 1.265 1.355 1.240 1.330 1.190 1.275

750AEIC – – – – 1.430 1.530 1.370 1.460ICEA – – 1.460 1.550 1.430 1.520 1.370 1.460

�000AEIC – – – – 1.575 1.680 1.520 1.610ICEA – – 1.610 1.705 1.575 1.670 1.520 1.610

25kV Cable (�00% level, 260 mil)Aluminum & Copper Conductor

Sizeindustry Standard

Solid Conductor Stranded Conductor Compressed Conductor Compact ConductorDiameterinInchesover insulation

DiameterinInchesover insulation

DiameterinInchesover insulation

DiameterinInchesover insulation

min. Max. min. Max. min. Max. min. Max.

#�AEIC 0.805 0.900 – – 0.835 0.935 0.815 0.910ICEA 0.805 0.895 0.845 0.935 0.835 0.925 0.815 0.905

�/0AEIC 0.840 0.940 – – 0.875 0.975 0.850 0.945ICEA 0.840 0.930 0.885 0.980 0.875 0.965 0.850 0.940

2/0AEIC – – – – 0.920 1.020 0.890 0.985ICEA – – 0.935 1.025 0.920 1.010 0.890 0.980

3/0AEIC – – – – 0.970 1.070 0.935 1.035ICEA – – 0.985 1.075 0.970 1.060 0.935 1.030

�/0AEIC – – – – 1.025 1.125 0.990 1.085ICEA – – 1.040 1.135 1.025 1.115 0.990 1.080

250AEIC – – – – – – – –ICEA – – 1.095 1.190 1.080 1.175 1.040 1.135

350AEIC – – – – 1.185 1.295 1.140 1.245ICEA – – 1.205 1.295 1.185 1.275 1.140 1.230

500AEIC – – – – 1.310 1.425 1.260 1.365ICEA – – 1.335 1.430 1.310 1.405 1.260 1.350

750AEIC – – – – 1.500 1.620 1.440 1.550ICEA – – 1.530 1.625 1.500 1.595 1.440 1.535

�000AEIC – – – – 1.645 1.770 1.590 1.700ICEA – – 1.680 1.775 1.645 1.740 1.590 1.685

ICEANOTE:DiametersspecifiedintheabovetablesaredifferentthanspecifiedbyAEICCS8-00.ConsultAccessoryManufac-turer for proper selection of accessories. Diameters to be measured in accordance with 9.6.

Page 15: CABLE ACCESSORIES - Border States Electric€¦ · PG-CA-0307 Use Tables W9 and X6 CAM-OP and

CABLE ACCESSORIESr

efer

ence

36 Thomas & Betts Corporation 8155 T&B Boulevard Memphis TN 38125 800.888.0211 www.tnb.com/utility PG-CA-0307

AEIC & ICEA Cable Insulation Diameter

35kV Cable (�00% level, 3�5 mil)Aluminum & Copper Conductor

Sizeindustry Standard

Solid Conductor Stranded Conductor Compressed Conductor Compact ConductorDiameterinInchesover insulation

DiameterinInchesover insulation

DiameterinInchesover insulation

DiameterinInchesover insulation

min. Max. min. Max. min. Max. min. Max.

�/0 AEIC 1.010 1.110 – – 1.045 1.145 1.020 1.115ICEA 1.010 1.110 1.055 1.155 1.045 1.145 1.020 1.120

2/0AEIC – – – – 1.090 1.190 1.060 1.155ICEA – – 1.105 1.200 1.090 1.190 1.060 1.160

3/0 AEIC – – – – 1.140 1.240 1.105 1.205ICEA – – 1.155 1.255 1.140 1.240 1.105 1.205

�/0 AEIC – – – – 1.195 1.295 1.160 1.255ICEA – – 1.210 1.310 1.195 1.295 1.160 1.260

250 AEIC – – – – – – – –ICEA – – 1.265 1.370 1.250 1.350 1.210 1.315

350 AEIC – – – – 1.355 1.470 1.310 1.420ICEA – – 1.375 1.475 1.355 1.455 1.310 1.410

500 AEIC – – – – 1.480 1.600 1.430 1.540ICEA – – 1.505 1.605 1.480 1.580 1.430 1.530

750 AEIC – – – – 1.670 1.795 1.610 1.725ICEA – – 1.700 1.800 1.670 1.770 1.610 1.710

�000 AEIC – – – – 1.815 1.945 1.760 1.875ICEA – – 1.850 1.955 1.815 1.920 1.760 1.865

ICEANOTE:DiametersspecifiedintheabovetablearedifferentthanspecifiedbyAEICCS8-00.ConsultAccessoryManufac-turer for proper selection of accessories. Diameters to be measured in accordance with 9.6.

Page 16: CABLE ACCESSORIES - Border States Electric€¦ · PG-CA-0307 Use Tables W9 and X6 CAM-OP and

CABLE ACCESSORIESr

eference

37Thomas & Betts Corporation 8155 T&B Boulevard Memphis TN 38125 800.888.0211 www.tnb.com/utilityPG-CA-0307

Cable Conductor Diameter

Conductor no. of Strands Cross-sectional Area Stranded Compressed Compact Solid Size and their nom. Square mm2 Conductors Conductors Conductors Conductors AWG or kcmil Strand Dia. (in.) inches Conversion (inches) (inches) (inches) (inches)

�� 7 x .0242 .0032 2.08 .073 .— .— .064 �2 7 x .0305 .0051 3.31 .092 .— .— .081 �0 7 x .0385 .0082 5.26 .116 .— .— .102 8 7 x .0486 .0130 8.37 .146 .— .— .129 6 7 x .0612 .0206 13.30 .184 .— .— .162 � 7 x .0772 .0328 21.15 .232 .— .— .204 2 7 x .0974 .0521 33.62 .292 .283 .268 .258

� 19 x .0664 .0657 42.41 .332 .322 .299 .289 �/0 19 x .0745 .0829 53.49 .373 .362 .336 .325 2/0 19 x .0837 .1054 67.43 .418 .405 .376 .— 3/0 19 x .0940 .1318 85.01 .470 .456 .423 .— �/0 19 x .1055 .1662 107.2 .528 .512 .475 .—

250 37 x .0822 .1964 127 .575 .558 .520 .— 350 37 x .0973 .2749 177 .681 .661 .616 .— 500 37 x .1162 .3924 253 .813 .789 .736 .—

600 61 x .0992 .4712 304 .893 .866 .813 .— 700 61 x .1071 .5498 355 .964 .935 .877 .— 750 61 x .1109 .5890 380 .998 .968 .908 .— 800 61 x .1145 .6283 405 1.031 1.000 .938 .— 900 61 x .1215 .7069 456 1.094 1.061 .999 .— �000 61 x .1280 .7854 507 1.152 1.117 1.060 .—

��00 91 x .1099 .8639 557 1.209 1.173 .— .— �200 91 x .1148 .9425 608 1.263 1.225 .— .— �250 91 x .1172 .9818 633 1.289 1.250 .— .— �300 91 x .1195 1.021 659 1.315 1.276 .— .— ��00 91 x .1240 1.100 709 1.364 1.323 .— .— �500 91 x .1284 1.178 760 1.412 1.370 .— .—

�600 127 x .1122 1.257 811 1.459 1.415 .— .— �700 127 x .1157 1.335 861 1.504 1.459 .— .— �750 127 x .1174 1.374 887 1.526 1.480 .— .— �800 127 x .1191 1.414 912 1.548 1.502 .— .— �900 127 x .1223 1.492 963 1.590 1.542 .— .— 2000 127 x .1225 1.571 1010 1.632 1.583 .— .—

Conductor Diameters for Copper and Aluminum (Class B) Stranded, Compressed, Compact and Solid Cables

CABLECONDUCTOR

Page 17: CABLE ACCESSORIES - Border States Electric€¦ · PG-CA-0307 Use Tables W9 and X6 CAM-OP and

CABLE ACCESSORIESr

efer

ence

W

X Ta

bles

38 Thomas & Betts Corporation 8155 T&B Boulevard Memphis TN 38125 800.888.0211 www.tnb.com/utility PG-CA-0307

Cable insulation Table W� Diameter in inches Symbol min. mAX. for W

.575 .740 A .635 .905 B .830 1.060 C .930 1.220 D

Cable insulation Table W�A Diameter in inches Symbol min. mAX. for W

.575 .740 A .635 .905 B .805 1.060 C .890 1.220 D

Cable insulation Table W2 Diameter in inches Symbol min. mAX. for W

.760 .950 G .850 1.050 H .980 1.180 J 1.090 1.310 K

Cable insulation Table W3 Diameter in inches Symbol min. mAX. for W

.850 1.050 H .980 1.180 J 1.090 1.310 K 1.235 1.465 L

Cable insulation Table W� Diameter in inches Symbol min. mAX. for W

.640 .820 F .760 .950 G .850 1.050 H .980 1.180 J 1.090 1.310 K

Cable insulation Table W5 Diameter in inches Symbol min. mAX. for W

.665 .895 6689 .740 .950 7495 .880 1.100 88110 1.090 1.310 K

Cable insulation Table W6 Diameter in inches Symbol min. mAX. for W

.495 .585 EB .525 .635 EF .575 .685 FA .625 .735 FAB .675 .785 FB .725 .835 FG .775 .885 GA .825 .935 GAB .875 .985 GB

Cable insulation Table W7 Diameter in inches Symbol min. mAX. for W

.640 .820 F .760 .950 G .850 1.050 H .980 1.180 J 1.090 1.310 K 1.180 1.465 L 1.280 1.430 LM 1.370 1.630 M 1.515 1.780 N 1.725 1.935 P

Cable insulation Table W8 Diameter in inches Symbol min. mAX. for W

.640 .820 F .760 .950 G .850 1.050 H .980 1.180 J 1.090 1.310 K 1.180 1.465 L 1.280 1.430 LM 1.370 1.630 M 1.515 1.780 N 1.725 1.935 P 1.900 2.120 Q

Cable insulation Table W9 Diameter in inches Symbol min. mAX. for W

.760 .950 G .850 1.050 H .980 1.180 J 1.090 1.310 K 1.180 1.465 L 1.280 1.430 LM 1.370 1.630 M 1.515 1.780 N 1.725 1.935 P 1.900 2.120 Q

Cable insulation Table W�0 Diameter in inches Symbol min. mAX. for W

.850 1.050 H .980 1.180 J 1.090 1.310 K 1.180 1.465 L 1.280 1.430 LM 1.370 1.630 M 1.515 1.780 N 1.725 1.935 P 1.900 2.120 Q

USE for foLLoWinG ProDUCTS

�65/�66Lr�65/�66LrJS

USE for foLLoWinG ProDUCTS

�5�SP/Sr�5�LS/LY

USE for foLLoWinG ProDUCTS

273rLr27�rLr

USE for foLLoWinG ProDUCTS

375rLr376rLr

USE for foLLoWinG ProDUCTS

�56Lr�67/�68rLr�67LrT

USE for foLLoWinG ProDUCTS

�67/�68ELr273/27�ELr

USE for foLLoWinG ProDUCTS

�0EP�52EA160CA*(*EB - FA Only)

USE for foLLoWinG ProDUCTSK656i/CY/CHK655/656LrK655/656Sr655/656LinKK655/656LinK655/656ETPK655/656ETP655/656rTPK655/656LrTP655/656Bi-LinKK655/656Bi-LinK655CA/CK/TCK

USE for foLLoWinG ProDUCTS

�5PCJ-��5PCJ-2

USE for foLLoWinG ProDUCTS

25PCJ-�25PCJ-2755/756Lr755/756LinK755/756ETP755/756LrTP755/756Bi-LinK755CA/CK/TCK

USE for foLLoWinG ProDUCTS

35PCJ-�35PCJ-2

Cable insulation Table W�� Diameter in inches Symbol min. mAX. for W

.495 .585 EB .525 .635 EF .575 .685 FA .625 .735 FAB .675 .785 FB .725 .835 FG .775 .885 GA .825 .935 GAB .875 .985 GB .930 1.040 GH .980 1.115 HA 1.040 1.175 HAB 1.095 1.240 HB 1.160 1.305 HJ 1.220 1.375 JA 1.285 1.395 JAB 1.355 1.520 JB 1.485 1.595 KA 1.530 1.640 KAB 1.575 1.685 KB 1.665 1.785 PA 1.755 1.875 PB

USE for foLLoWinG ProDUCTS

35mSC35mSCi

Cable insulation Table W�2 Diameter in inches Symbol min. mAX. for W

.495 .585 EB .525 .635 EF .575 .685 FA .625 .735 FAB .675 .785 FB .725 .835 FG .775 .885 GA .825 .935 GAB .875 .985 GB .930 1.040 GH .980 1.115 HA

USE for foLLoWinG ProDUCTS

�6THG�6THGS�6THGH

Cable insulation Table W�6 Diameter in inches Symbol min. mAX. for W

.800 1.060 CC .940 1.170 DD

USE for foLLoWinG ProDUCTS

275/276Lr275/276LrJS

Please see page 26 for Table W�3 and page 29 for Tables W�� and W�5.

WX Size Tables

Page 18: CABLE ACCESSORIES - Border States Electric€¦ · PG-CA-0307 Use Tables W9 and X6 CAM-OP and

CABLE ACCESSORIESr

eferenceW

X Tables

39Thomas & Betts Corporation 8155 T&B Boulevard Memphis TN 38125 800.888.0211 www.tnb.com/utilityPG-CA-0307

WX Size Tables

Conductor Symbol for X Table X� Size AWG Strand./ Compt./ or kcmil Compr. Solid. #4 200 190 #3 210 200 #2 220 210 #1 230 220 1/0 240 230 2/0 250 240 3/0 260 250 4/0 270 260 250 – 270

riser Conductor Size. Symbol Table X� AWG Solid for X #2 2 #1 2 1/0 10 2/0 20 3/0 30 4/0 30

Conductor Symbol for X Table X2 Size AWG Strand./ Compt./ or kcmil Compr. Solid. 1/0 240 230 2/0 250 240 3/0 260 250 4/0 270 260

USE for foLLoWinG ProDUCTS

375/376Lr

USE for foLLoWinG ProDUCTS

�67/�68ELr273/27�ELr�56Lr�65/�66Lr275/276Lr�67LrT�67/�68rLr273/27�rLr00�0002500025090270202800K�5�SP/SrK�5�LS/LY

Conductor Symbol for X Table X3 Size AWG Strand./ Compt./ or kcmil Compr. Solid. #6 5 – #5 4 5 #4 3 4 #3 2 3 #2 1 2 #1 0 1 1/0 10 0 2/0 20 10 3/0 30 20 4/0 40 30 250 250 40 300 300 250 350 350 300 400 400 350 450 450 – 500 500 400 550 550 450 600 600 500 650 650 550 700 750 600 750 750 650 800 800 750 900 900 800 1000 1000 900

USE for foLLoWinG ProDUCTS

35mTGnoTE: SEE PAGE 2� for DETAiLED APPLiCATion informATion

Conductor Symbol for X Table X3A Size AWG Strand./ Compt./ or kcmil Compr. Solid. 400 400 – 450 450 400 500 500 450 550 550 500 600 600 500 650-700 650 550 750 750 600 800 750 650 1000 1000 –

USE for foLLoWinG ProDUCTS

35mTGnoTE: SEE PAGE 2� for DETAiLED APPLiCATion informATion

Conductor Symbol for X Table X6 Size AWG Strand./ Compt./ or kcmil Compr. Solid. #2 220 210 #1 230 220 1/0 240 230 2/0 250 240 3/0 260 250 4/0 270 260 250 280 270 300 290 280 350 300 290 400 310 300 450 320 310 500 330 320 550 340 320 600 350 330 650 360 340 700 380 350 750 380 360 800 390 360 900 400 380 1000 410 400 1250 440 420

USE for foLLoWinG ProDUCTS

655/656LrTPK655/656LrTP755/756LrTPK656i/Y/HK655/656Lr755/756LrK655/656Sr655/656LinKK655/656LinK755/756LinK655/656ETPK655/656ETP755/756ETP655/656Bi-LinKK655/656Bi-LinK755Bi-LinK655CK755CK655TCK03600036020370003702

USE for foLLoWinG ProDUCTS

�6THGS�6CAS

Conductor Symbol for X Table X7 Size AWG Strand./ Compt./ or kcmil Compr. Solid. #6 180 – #5 190 180 #4 200 190 #3 210 200 #2 220 210 #1 230 220 1/0 240 230 2/0 250 240 3/0 260 250 4/0 270 260 250 280 270 300 290 280 350 300 290 400 310 300 450 320 310 500 330 310 550 340 320 600 350 330 650 360 340 700 380 350 750 380 360 800 390 380 900 400 380 1000 410 400 1250 440 420

USE for foLLoWinG ProDUCTS

�5PCJ�25PCJ�35PCJ��5PCJ225PCJ235PCJ2

Conductor Symbol for X Table X8 Size AWG Strand./ Compt./ or kcmil Compr. Solid. #6 180 – #5 190 180 #4 200 190 #3 210 200 #2 220 210 #1 230 220 1/0 240 230 2/0 250 240 3/0 260 250 4/0 270 260

USE for foLLoWinG ProDUCTS

�6THG�6TCA

Conductor Symbol for X Table X9 Size AWG Strand./ Compt./ or kcmil Compr. Solid. #2 220 210 #1 230 220 1/0 240 230 2/0 250 240 3/0 260 250 4/0 270 260

USE for foLLoWinG ProDUCTS

PCT�PCT20�0000�0�0