Cable Connections Insulated Non Insulated 2015-16

TRANSCRIPT

  • Small parts, big impact.

    To guarantee ultimate safety at all times, speci c quality and installation requirements exist for insulated and non-insulated connections. We often hear about technical failures being caused by faulty connections. Thats why quality is so important. Because when it comes to electrical connections, minor causes can have major, expensive consequences.

    For optimum processing of Klauke connecting materials, we therefore recommend the use of Klauke tools. A harmonised system for professional users in trade and industry.

    Insulated and non-insulated cableconnections.

    Insulated and non-insulated cable connections for professional users.

    Halogen-free insulation.

    Insulated connectors, heat resistant to 105C.

    Hard-soldered in the crimping area.

    The Klauke range carries various designs of both insulated and non-insulated cable connections for diverse applications.

    172

    Klauke Hauptkatalog EN_DIN A5.indb 172 07.10.2014 12:17:24

  • Heat resistant insulation to 105 C. Cable connections with nominal cross-sections from

    0.1 mm2 to 6 mm2.

    Halogen-free and heat resistant to 105 C.

    Simple processing thanks to easy-entry insulation.

    Hard-soldered in the crimping area.

    Grooved pro le on the inside.

    Bene ts: The use of these optimised quality materials guarantees reliable

    electrical connections.

    Electrical conductivity is maintained, even at higher temperatures.

    Halogen-free, ame-retardant polyamide insulation releases no toxic vapours in case of re.

    Easy-entry polyamide insulation for simple conductor insertion.

    High-tensile strength thanks to grooved pro le in the crimping area permits higher mechanical continuous stress.

    Standardised connectors with 2.8; 4.8; 6.3 and 9.5 mm tab width.

    With grooved pro le and additional copper ring in the insulation area.

    Receptacles, multiple type.

    Fully-insulated receptacles.

    Bene ts: Standardised tabs enable use for a broad range of applications,

    including control installations and machine wiring.

    The grooved pro le increases the hold in the crimping area.

    The connections relieved by copper rings in the crimping area better withstand stresses and vibrations.

    More from Page 179.

    With indent point for de ned pulling forces. Receptacle with indent point.

    For harmonised, exible cables.

    Receptacles also available in bronze.

    Bene ts: The additional indent point increases the mechanical rating and

    guarantees that the connections will withstand the de ned pulling forces even after repeated pulling actions.

    Thanks to the materials improved spring characteristics, connectors with bronze receptacles have a higher contact strength and are able to better withstand mechanical stresses, especially at high temperatures.

    More from Page 179.

    Receptacles with strain relief.

    173