NYY LOW VOLTAGE NON ARMOURED CABLE (COPPER CONDUCTOR, PVC INSULATED AND PVC SHEATHED)
T y p e of C a b l e
Ra ted Vo l t age
Size Range
Spec i f i ca t i on
NYY
0.6/1 kV
1 x 1.5 ... 500 m m 2
2 x 1 . 5 ... 150 m m 2
3 x 1.5 ... 300 m m 2
4 x 1.5 ... 300 m m 2
5 x 1.5 ... 50 m m 2
7 x 1.5 ... 61 x 6 m m 2
SPLN 43-1 : 1994
SNI 04 -2701 -1999
VDE 0271
IEC 60502
Other Spec i f i ca t i on a t e ava i l ab l e o n reguest
App l i ca t i on
Ident i f i ca t ion o f Co tes
Single-Core
Twin-Cores
Three-Cores
Four-Cores
Five-Cores
A b o v e Five Cores
Indoor a n d Ou tdoo r
i n d u c t insta l lat ion or o f
lay ing in t h e g r o u n d where
not sustain m e c h a n i c a l
d a m a g e
Black
Light-Blue, Black
System 1
Green/Yel low, L ight-b lue, Black
System O
Light-Blue, Yellow, Black
System 1
Green/Yel low, Light-blue
Yel low, Black
System O
L ight -b lue, Red
Yel low, Black
Green/Yel low, L ight-b lue,
Red, Yel low, Black
Black with whi te n u m b e r
Other colours are available on request
Construction :
1. Annealed Copper Conductor
2. Extruded PVC Insulated
3. Extruded PVC Outer Sheathed
SINGLE - CORE NON ARMOURED CABLE
Type of Cable Rated Voltage
NYY 0.6/1 kV
Specification : SPLN 43-1 : SNI 04-270' IEC 60502
(other specifications are available on request)
1994 : 1999
CONSTRUCTION
No. Of Core
-
Size
m m 2
1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500
Conductor
Construct ion
-
re/rm re/rm re/rm re/rm re/rm
rm rm rm rm rm rm rm rm rm rm rm rm rm
No. of Wire
-
1/7 1/7 1/7 1 1 7 7 7 19
19 19 37 37 37 61 61 61 61
Wall Thickness
Insulation
m m
0.8 0.9 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4
1.6 1.6 1.8 2.0 2.2 2.4
2.6 3.0
Sheath
m m
1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 2.0 2.0 2.0 2.2 2.2
1] m m
6.8 7.4 8.0 8.5 9.4 10.8 12.5 13.8 15.8 17.2 19.4
21.0 23.0 25.6 28.6 31.3 35.1 38.9
Approx Net. Weight
Kg/Km
69 80 103 130 175 252 365 470 645 832 1115 1360 1680 2070 2685 3294
4210 5240
Standard Length
m
100 100 100 100 100 100
1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
Packing
-
C d l Coil Coll Coil Coil Coil
Drum Drum Drum Drum Drum Drum Drum Drum Drum Drum Drum Drum
CHARACTERISTICS
No Of. Core
-
1 1 1 1 1 1 1 1 1
Size
m m 2
1.5 2.5
4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500
Resistance at 20"C
Conductor Insulation
O h m / k m M.Ohm.km
12.1 7.41 4.61 3.08 1.83 1.15
0.727 0.524 0.387
0.268 0.193 0.153 0.124
0.0991
0.0754 0.0601 0.0470
0.0366
50 50 50 40 30 30 30 20 20 20 20 20 20 20 20 20 20 20
Current Cary ing Capac i ty at 30"C
In Ground In Air
( & / G 0 0 $ > / G 0 ©
Amper
33 45 58 74 98
129 / 132 1 6 9 / 1 7 2 2 1 0 / 2 1 4 250 / 255 3 1 0 / 3 1 6 375 / 383 425 / 434 4 8 0 / 4 9 0 550 / 561 6 4 0 / 6 5 3 7 3 0 / 7 4 5 8 5 5 / 8 7 2
9 9 0 / 1 0 1 0
Amper
26 35 46 58 80
1 0 5 / 1 0 7 1 4 0 / 1 4 3 1 7 5 / 1 7 9 2 1 5 / 2 1 9 2 7 0 / 2 7 5 335 / 342 390 / 398 4 4 5 / 4 5 4
5 1 0 / 5 2 0 6 2 0 / 6 3 2 7 1 0 / 7 2 4 8 5 0 / 8 6 7
1000 /1020
Short Circuit Current at
I sec.
KA
0.17 0.29 0.46 0.70 1.16 1.86 2.91 4.07 5.81 8.14 11.05 13.95 17.44
21.51 27.91 34.88 46.51 58.14
AC Voltage Test
K V / 5 m i n
3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5
Note': It site condition are different ratings should be multiplied by rating factors as show In table page 78-83
TWIN - CORES NON ARMOURED CABLED ^CINSUI NDSH1
Type of Cable Rated Voltage
NYY 0,6/1 kV
Specification : SPLN 43-1 : 1994 SNI 04-2701 : 1999 IEC 60502
(other specifications ore available on reauest)
CONSTRUCTION
No. of Core
•
2 2 2 2 2 2 2 2 2 2 2 2 2
Size
m m 2
1.5 2.5 4 6 10 16 25 35 50 70 95 120 150
Conductor
Construction
•
re/rm re/rm re/rm re/rm re/rm
rm rm rm
rm/sm rm/sm rm/sm rm/sm rm/sm
No. of Wire
-
1/7 1/7 1/7
1 1 7
7 7 19 19 19 37 37
Wall Thickness
Insulation
m m
0.8 0.9 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8
Sheath
m m
1,8 1,8 1.8 1.8 1.8 1.8 2.0 2.0 2.0 2.2 2,2 2,2 2.6
Approx Overall
Diameter
m m
11.4 12.5 13.8 14.8 16.4 19.4 23.9 30.0 30.0 32.9 37.9 41.1 45,9
Approx Net. Weight
Kg/Km
170 216 280 341 451 669 1033 1310 1748 2232 2982 3565 4538
Standard Length
m
100 100 100 100 100
1000 1000 1000 1000 1000 500 500 500
Packing
-
Coll Coll Coil Coil Coil Coil
Drum Drum Drum Drum Drum Drum Drum
CHARACTERISTICS
N<5£ si~
m m 2
2 1.5 2 2.5 2 4 2 6 2 10 2 16 2 25 2 35 2 50 2 70 2 95 2 120 2 150
Resistance at 20'C
Conductor Insulation
O h m / k m
12.1 7.41 4.61 3.08 1.83 1.15
0.727 0.524 0.387 0.268 0.193 0.153 0.124
M.Ohm.km
50 50 50 40 30 30 30 20 20 20 20 20 20
Current Carylng Capac i ty at 30 'C
In Ground In Air
Short Circuit AC Vol tage 1 sec. T e s t
Amper Amper KA
27 36 47 59 78 102 134 160 187 230 280 320 355
21 29 38 48 66 90 120 150 180 230 275 320 375
0.17 0.29 0.46 0.70 1.16 1.86 2.90 4,06 5,80 8.12 11.02 13.92 17.40
K V / 5 m l n
3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5
Note': If site condition ore different ratings should be multiplied by rating factors as show in table page 78-83
THREE - CORES NON ARMOURED CABLED ■
Type of Cable Rated Voltage
NYY 0.6/1 kV
Specification : SPLN 43-1 : SNI 04-270' IEC 60502
(other specifications are available on request)
1994 : 1999
CONSTRUCTION
No. Of Core
-
3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3
Size
m m 2
1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300
Conductor
Construct ion No. of Wire
-
re/rm 1/7 re/rm re/rm re/rm re/rm
rm rm rm sm sm sm sm sm sm sm
1/7 1/7 1 1 7 7 7 19
19 19 37 37 37 61
sm 61
Wall Thickness
Insulation
m m
0.8 0.9 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4
1.6 1.6 1.8 2.0 2,2 2,4
Sheath
m m
1.8 1.8 1.8 1.8 1.8 1.8 2.0 2.0 2.0 2.0 2.2 2.2 2.6 2.6 2.6 3.0
Approx Overal l
Diameter
m m
11.8 13.0 14.5 15.6 17.3 21.3 25.3 27.9 27.9 31.2 35.7 38.3 42.3 46.9 51.7
56.2
Approx Net. Weight
Kg/Km
192
251 330 413 563 882 1302 1670 1945 2613 3467 4217 5234
6478 9102
10020
Standard Length
m
100 100 100 100 100 1000 1000 1000 1000 500 500 500 300 300 250 250
Packing
•
Coil Coil Coil Coil Coil
Drum Drum Drum Drum Drum Drum Drum Drum Drum Drum Drum
CHARACTERISTICS
No Of. Core
-
3
3 3
3 3 3 3 3 3 3 3 3 3 3 3 3
Size
m m 2
1.5 2.5
4 6 10 16 25 35 50 70 95 120 150 185 240 300
Resistance at 20"C
Conductor Insulation
O h m / k m M.Ohm.km
12.1 7.41 4,61 3.08 1,83 1.15
0.727 0.524 0.387
0.268 0.193 0.153 0.124
0.0991
0.0754 0.0601
50 50 50 40 30 30 30 20 20 20 20 20 20 20 20 20
Current Cary lng Capac i ty at 30'C
In Ground
Amper
24 32 42 53 69 91 119 142 166 205 249 285 316 355 415 465
In Air
Amper
19 26 34 43 59 80 107 134
160 205 245 285 325 370 435 500
Short Circuit Current at
I sec.
KA
0.17 0.29 0.46 0.70 1,16 1.86 2.90 4.06 5.80 8.12 11,02 13.92 17.40 21.51 27,91 34.88
AC Voltage Test
K V / 5 m l n
3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5
Note': If site condition are different ratings should be multiplied by rating factors as show in table page 78-83
FOUR- CORES NON ARMOURED CABLED NSUL iND
Type of Cable Rated Voltage
NYY 0,6/1 kV
Specification : SPLN 43-1 : 1994 SNI 04-2701 : 1999 IEC 60502
(other specifications ore available on reauest)
CONSTRUCTION
No. of Core
•
4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4
Size
mm2
1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300
Conductor
Construction
•
re/rm re/rm re/rm re/rm re/rm
rm rm rm sm sm sm sm sm sm sm sm
No. of Wire
-
1/7 1/7 1/7 1 1 7 7 7
19 19 19 37 37 37 61 61
Wall Thickness A p p m x
Insulation
mm
0.8 0.9 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 2.4
Sheath Diameter
mm mm
1,8 12.5 1,8 14.0 1.8 15.7 1.8 16.9 1.8 18,7 1.8 23.6 2.0 27.6 2.0 30.6 2.0 30.6 2.2 33.8 2,2 39.0 2,2 42.2 2.6 47.1 2.6 51.7 3.0 57.5 3.4 65.9
Approx Net. Weight
Kg/Km
225 299 399 503 697 1117 1625 2096 2388 3205 4225 5264 5526 8033 10633 13343
Standard Length
m
100 100 100 100 1000 1000 1000 1000 1000 500 500 500 300 300 250 200
Coll Coll Coil Coil
Drum Drum Drum Drum Drum Drum Drum Drum Drum Drum Drum Drum
CHARACTERISTICS
No Of. Core
-
4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4
Size
mm2
1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300
Resistance at 20'C
Conductor Insulation
Ohm/km
12.1 7.41 4.61 3.08 1.83 1.15
0.727 0.524 0.387 0.268 0.193 0.153 0.124
0.0991 0.0754 0.0601
M.Ohm.km
50 50 50 40 30 30 30 20 20 20 20 20 20 20 20 20
Current Carylng Capacity at 30'C
In Ground In Air
Amper Amper
24 32 42 53 69 91 119 142 166 205 249 285 316 355 415 465
19 26 34 43 59 80 107 134 160 205 245 285 334 370 435 500
Short Citcuit Current at
1 sec.
KA
0.17 0.29 0.46 0.70 1.16 1.86 2.90 4.06 5.80 8.12 11.02 13.92 17.40 21.51 27.91 34.88
AC Voltage Test
KV/5mln
3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5
Note': If site condition are different ratings should be multiplied by rating factors as show in table page 78-83
FIVE - CORES NON ARMOURED CABLED PVC IN
Type of Cable Rated Voltage
NYY 0.6/1 kV
Specification : SPLN 43-1 : SNI 04-270' IEC 60502
(other specifications are available on request)
1994 : 1999
CONSTRUCTION
No. Of Core
•
5 5 5 5 5 5 5 5 5
Size
mm2
1.5 2.5 4 6 10 16 25 35 50
Conductor
Construction
-
re/rm re/rm re/rm re/rm re/rm rm rm rm
rm/sm
No. of Wire
1/7 1/7 1/7 1/7 1/7
7 7 7 19
Wall Thickness
Insulation
mm
0.8 0.9 1.0 1.0 1.0 1.0 1.2 1.2 1.4
Sheath
1] mm mm
1.8 1.8 1.8 1.8 1.8 2.0 2.0 2.0 2.0
13.3 15.0 16.9 18.8 20.3 25.9 29.8 33.1 38.1
Approx Net. Weight
Kg/Km
260 346 468 591 828 1331 1918 2491 3427
Standard Length
m
100 100 100 100 1000 1000 1000 1000 500
Packing
•
Coil Coil Coil Coil
Drum Drum Drum Drum Drum
CHARACTERISTICS
No Of. Core
-
5 5 5 5 5 5 5 5 5
Size
mm2
1.5 2.5 4 6 10 16 25 35 50
Resistance at 20"C
Conductor Insulation
Ohm/km M.Ohm.km
12.1 7.41 4.61 3.08 1.83 1.15
0.727 0.524 0.387
50 50 50 40 30 30 30 20 20
Current Carylng Capacity at 30'C
In Ground In Air
Amper Amper
24 19 32 42 53 69 91 119 142
26 34 43 59 80 107 134
166 160
Short Circuit Current at
I sec.
KA
0.17 0.29 0.46 0.70 1,16 1.86 2.90 4.06 5.80
AC Voltage Test
KV/5mln
3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5
Note': If site condition are different ratings should be mulliplied by rating factors as show in table page 78-83
NON ARMOURED CONTROL CABLED NSUI iND
Type of Cable Rated Voltage
NYY 0.6/1 kV
Specification : SPLN 43-1 : 1994 SNI 04-2701 : 1999 IEC 60502
(other specifications ore available on reauest)
CONSTRUCTION
No. Of Core
•
7 8 10 12 14 16 19 21 24 30 40 52 61
Size
mm2
1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5
Conductor
Construction
•
re/rm re/rm re/rm re/rm re/rm re/rm re/rm re/rm re/rm re/rm re/rm re/rm re/rm
No. of Wire
-
1/7 1/7 1/7 1/7 1/7 1/7 1/7 1/7 1/7 1/7 1/7 1/7 1/7
Wall Thickness
Insulation
mm
0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 08
Sheath
mm
1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 2.0 2.0 2.0 2.0 2.0
Approx Overall
Diameter
mm
13.7 16.7 16.7 17.6 17.6 18.6 19.6 22.5 22.5 24.5 29.4 30.4 32.4
Approx Net. Weight
Kg/Km
304 348 372 471 485 580 599 681 744 903 1184 1444 1681
Standard Length
m
500 500 500 500 500 500 500 500 500 500 500 500 500
Packing
-
Drum Drum Drum Drum Drum Drum Drum Drum Drum Drum Drum Drum Drum
CHARACTERISTICS
No Of. Core
-
7 8 10 12 14 16 19 21 24 30 40 52 61
Size
mm2
1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5
Resistance at 20'C
Conductor Insulation
Ohm/km
12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1
M.Ohm.km
50 50 50 50 50 50 50 50 50 50 50 50 50
Current Carving Capacity at 30'C
In Ground In Air
Amper Amper
14 10 14 12 10 10 10 9 8 8 8 7 7 6
10 9 8 8 8 8 7 7 7 6 6 5
Short Circuit Current at
1 sec.
KA
0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17
AC Voltage Test
KV/5mln
3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5
Note': If site condition are different ratings should be multiplied by rating factors as show In table page 78-83
NON ARMOURED CONTROL CABLED (COPPER
Type of Cable Rated Voltage
: NYY : 0.6/1 kV
Specification : SPLN 43-1 : SNI 04-270' IEC 60502
(other specifications are available on request)
1994 : 1999
CONSTRUCTION
No. Of Core
-
7 8 10 12 14 16 19 21 24 30 40 52 61
Size
mm 2
2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
Conductor
Construction
-
re/rm re/rm re/rm re/rm re/rm re/rm re/rm re/rm re/rm re/rm re/rm re/rm re/rm
No. of Wire
1/7 1/7 1/7 1/7 1/7 1/7 1/7 1/7 1/7 1/7 1/7 1/7 1/7
Wall Thickness
Insulation
mm
0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8
Sheath
Approx Overall
Diameter
mm mm
1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 2.0 2.0 2.0 2.0 2.0
15.7 18.5 18.6 20.6 20.6 21.6 24.6 26.5 26.5 28.4 34.3 36.3 38.2
Approx Net. Weight
Kg/Km
423 483 522 691 710 768 1001 1038 1097 1295 1758 2179 2512
Standard Length
m
500 500 500 500 500 500 500 500 500 500 500 500 500
Packing
•
Drum Drum Drum Drum Drum Drum Drum Drum Drum Drum Drum Drum Drum
CHARACTERISTICS
No of. Core
-
7 8 10 12 14 16 19 21 24 30 40 52 61
Size
mm2
2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
Resistance at 20"C
Conductor Insulation
Ohm/km M.Ohm.km
7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41
50 50 50 50 50 50 50 50 50 50 50 50 50
Current Carylng Capacity at 30'C
In Ground
Amper
19 19 16 14 14 14 12 11 11 11 10 0 8
In Air
Amper
16 16 13 12 12 12 12 11 11 11 9 9 8
Short Circuit Current at
I sec.
KA
0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29
AC Voltage Test
KV/5mln
3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5
Note': If site condition are different ratings should be multiplied by rating factors as show In table page 78-B3
NON ARMOURED CONTROL CABLED NSUI iND
Type of Cable Rated Voltage
NYY 0.6/1 kV
Specification : SPLN 43-1 : 1994 SNI 04-2701 : 1999 IEC 60502
(other specifications ore available on reauest)
CONSTRUCTION
No. Of Core
•
7 8 10 12 14 16 19 21 24 30 40 52 61
Size
m m 2
4 4 4 4 4 4 4 4 4 4 4 4 4
Conductor
Construction No. of Wire
•
re/rm re/rm re/rm re/rm re/rm re/rm re/rm re/rm re/rm re/rm re/rm re/rm re/rm
-
1/7 1/7 1/7 1/7 1/7 1/7 1/7 1/7 1/7 1/7 1/7 1/7 1/7
Wall Thickness
Insulation
m m
1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
Sheath
m m
1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 2.0 2.0 2.0 2.0 2.0
Approx Overall
Diameter
m m
17.6 22.5 22.5 22.5 23.5 25.5 26.5 31.4 31.4 33.3 40.2 42.2 44.1
Approx Net. Weight
Kg/Km
522 696 754 864 976 1116 1275 1444 1594 1913 2560 3203 3691
Standard Length
m
500 500 500 500 500 500 500 500 500 500 500 500 500
Packing
-
Drum Drum Drum Drum Drum Drum Drum Drum Drum Drum Drum Drum Drum
CHARACTERISTICS
■&S- si~
m m 2
7 4 8 4 10 4 12 4 14 4 16 4 19 4 21 4 24 4 30 4 40 4 52 4 61 4
Resistance at 20 'C
Conductor Insulation
O h m / k m
4.61 4.61 4.61 4.61 4.61 4.61 4.61 4.61 4.61 4.61 4.61 4.61 4.61
Current Carving Capac i ty at 30"C
In Ground In Air
Short Circuit AC Vol tage 1 sec. T e s t
M.Ohm.km Amper Amper KA
50 50 50 50 50 50 50 50 50 50 50 50 50
24 24 20 18 18 18 17 15 15 15 13 13 11
22 22 18 17 17 17 16 14 14 14 12 12 10
0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46 0.46
K V / 5 m l n
3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5
Note': It site condition are different ratings should be multiplied by rating factors as show In table page 78-83
16
NON ARMOURED CONTROL CABLED (COPPER
Type of Cable Rated Voltage
: NYY : 0.6/1 kV
Specification : SPLN 43-1 : SNI 04-270' IEC 60502
(other specifications are available on request)
1994 : 1999
CONSTRUCTION
No. Of Core
-
7 8 10 12 14 16 19 21 24
30 40 52 61
Size
m m 2
6 6 6 6 6 6 6 6 6 6 6 6 6
Conductor
Construct ion
-
re/rm re/rm re/rm re/rm re/rm re/rm re/rm re/rm re/rm re/rm re/rm re/rm re/rm
No. of Wire
1/7 1/7 1/7 1/7 1/7 1/7 1/7 1/7 1/7 1/7 1/7 1/7 1/7
Wall Thickness
Insulation
m m
1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
Sheath
m m
1.8 1.8 1.8 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0
Approx Overal l
Diameter
m m
18.6 23.5 23.5 24.5 26.5 27.5 29.5 34.3 34.3 35.3 44.1 46.0 49.0
Approx Net. Weight
Kg/Km
681 874 986 1169 1314 1478 1681 1974 2155 2594 3464
4401 5087
Standard Length
m
500 500 500 500 500 500 500 500 500 500 500 500 500
Packing
•
Drum Drum Drum Drum Drum Drum Drum Drum Drum Drum Drum Drum Drum
CHARACTERISTICS
No Of. Core
-
7
8 10 12 14 16 19 21 24
30 40 52 61
Size
m m 2
6
6 6
6 6 6 6
6 6 6 6 6 6
Resistance at 20"C
Conductor Insulation
O h m / k m M.Ohm.km
3.08 3.08 3.08 3.08 3.08 3.08 3.08 3.08 3.08 3.08 3.08 3.08 3.08
40 40 40 40 40 40 40 40 40 40 40 40 40
Current Cary lng Capac i ty at 30'C
In Ground In Air
Amper Amper
31 28 31 26 23 23 23 23 2.0 2.0 2.0 15 15 13
28 24 22 22 22 22 19 19 19 15 15 13
Short Circuit Current at
I sec.
KA
0.69 0.69 0.69 0.69 0.69 0.69 0.69 0.69 0.69 0.69 0.69 0.69
0.69
AC Voltage Test
K V / 5 m l n
3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5
Note': If site condition are different ratings should be multiplied by rating factors as show In table page 78-83
17