2
www.glendinningprods.com RLCD_v2.0 740 Century Circle Conway, SC 29526 P: 843-399-6146 F: 843-399-5005 SPECIFICATIONS: Voltage: 12 VDC Amperage: 7-9 amps Weight: 14 lbs. Cable size: 6/3 8/1 and 6/4 50amp 125/250 v AC Length of cable: determined by available storage space Cable type: S, SE, SO, ST, STO, or SOW CABLEMASTER DIMENSIONS 10.0 in [254mm] 10.0 in [254mm] Cable Tension Adjustment Manual Override Control Switch Motor 8.0 in [203mm] 16.0 in [406mm] 21.0 in [533mm] 14.0 in [356mm]

Upload: glendinning-marine-products-inc

Post on 30-Mar-2016

214 views

Category:

Documents


1 download

DESCRIPTION

http://glendinninginc.com/gmp/pdf/cablemaster/cm-models/rlc/Cablemaster_RLC_-_Dimensions.v2.pdf

TRANSCRIPT

Page 1: Cablemaster_RLC_-_Dimensions.v2

www.glendinningprods.comRLCD_v2.0

740 Century CircleConway, SC 29526

P: 843-399-6146F: 843-399-5005

SPECIFICATIONS:

Voltage: 12 VDC

Amperage: 7-9 amps

Weight: 14 lbs.

Cable size: 6/3 8/1 and 6/4 50amp 125/250 v AC

Length of cable: determined by available storage space

Cable type: S, SE, SO, ST, STO, orSOW

CABLEMASTER DIMENSIONS

10.0 in[254mm]

10.0 in[254mm]

Cable TensionAdjustment

Manual Override

Control Switch Motor

8.0 in[203mm]

16.0 in[406mm]

21.0 in[533mm]

14.0 in[356mm]

Page 2: Cablemaster_RLC_-_Dimensions.v2

23.0�in[584mm]

16.0�in[406mm]

Pigtail

13.0�in[330mm]

16.0�in[406mm]

Space�requirement�for�installation�of�the�“Packaged�Unit”�(includes�optional�storage�container)�is:�16.0�W�x�16.0�D�x�23.0�H�

The�“Packaged�Unit”�is�typically�installed�with�the�Cablemaster�in�the�upright�vertical�position�(shown).

The�“Packaged�Unit”�may�also�be�mounted�in�a�horizontal�configuration�by�turning�the�unit�on�it’s�side�and�mounting�it�to�the�side�or�back�wall�of�the�storage�space.

Optional�mounting�brackets�will�be�necessary�if�mounting�the�unit�in�the�horizontal�configuration.

14.0�in[356mm]

16.0�in[406mm]

21.0�in[406mm]

“Close�Coupled”Installation

“Packaged�Unit”Installation

Alternative�installation�-�turn�Cablemaster�on�side�and�mount�horizontally�to�side�or�back�wall�(optional�mounting�brackets�needed)

Alternative�installation�-�mount�Cablemaster�to�shelf�in�storage�space�(optional�undercoach�guide�roller�needed)

Space�requirement�for�installation�of�“Close�Coupled”unit�is:�16.0�W�x�14.0�D�x�21.0�H

For�typical�“close�coupled”�installation(shown),�mount�Cablemaster�to�roof�ofstorage�space�using�the�integral�mountingbrackets.�Power�cord�will�“free�fall”�intothe�storage�space�directly�underneath.

To�aid�in�containment�of�the�powercord,�it�is�advisable�to�wall�off�the�area�where�the�power�cord�will�be�stored.

An�alternative�installation�method�wouldbe�to�install�the�Cablemaster�on�a�shelfusing�the�integral�mounting�bracket�on�the�bottom�of�the�power�unit.�It�will�be�necessaryto�purchase�the�optional��undercoach�guide�roller�assembly�and�cut�a�hole�in�the�shelf�toallow�the�power�cord�to�“free�fall”�into�the�storagespace.