cad-cam - dynamic abutment solutions en · 2016-03-07 · milling guideline anatomic tooth design...
TRANSCRIPT
CAD-CAM
2
*Approval of total quality system assurance by notified body, according
to Community legislation, for sterile and medical devices Class IIa.
NOTE
3
INDEX
4 3.0 DYNAMIC SYSTEM SET FOR CAD-CAM
4 3.0 DYNAMIC TITANIUM BASES FOR CAD-CAM
5 WORKING GUIDELINE WITH CAD-CAM TITANIUM BASES
6 3.0 DYNAMIC TITANIUM BASES FOR CAD-CAM
8 3.0 DYNAMIC TITANIUM BASES AND SCANBODY
4
3.0 DYNAMIC SYSTEM SET FOR CAD-CAM
Titanium Base for Cad-Cam structures made of Zirconium, metal and PMMA, to pro-vide solutions to the correction of implants bad-positioned for unitary and multiple prosthesis.
Specifications and advantages:-Correction of screw entry from 0° to 30°.-Improved system increasing the useful life of the screw, and avoiding screw head damage and breakage. -Screws are supplied well-identified with batch number and product code to allow the correct traceability and the registration of each screw in the patient record.-Different lengths of each metrics to facilitate the adaptation to your milled structures.-Download STL files from website: http://www.dynamicabutment.com/soluciones_cadcam
Compatibilities-More than 450 compatibilities and continuous developing.-Screw list available in the website.
The screw-screwdriver set of 3.0 Dynamic Abutment® system is used in those cases which are necessary to rectify the entry of the screw due to an unfavorable position of the implants, improving the functionality and aesthetics of the milled prosthesis.
3.0 DYNAMIC TITANIUM BASES FOR CAD-CAM
-Totally machined, with precision of ± 10 microns, for a perfect adjustment with the implant.-Double height with side cut that allows the angulation up to 30º.-Can be used both for angled or straight fixation using the screw and screwdriver of 3.0 Dynamic Abutment®.-Exterior retentions that improve the prosthesis grip. -The height of the Titanium base from the base is 4mm (except for Multi-Unit Regular Platform and Straumann internal octagon Regular Platform).-Freedom of lateral movement of the screwdriver up to 90°.-Scannable scanbody of PEEK that allows the correct positioning of the Dynamic Titanium base in the CAD working area.
5
Scanbody file generated to work with CAD.
For the design of angled channel, the following files libraries are available. STL files for all compatibilities, and downloading packs:
Milling guideline
Anatomic tooth design made in CAD and subsequent CAM work.
Screw the Titanium Base over the implant. Then, fix the Scanbody which is adjusted to the Titanium Base thanks to its design avoiding its breakage.Example of elements order (fig. 1)
Example of final order of working set for Cad-Cam (fig.2)
WORKING GUIDELINE WITH CAD-CAM TITANIUM BASES
1 2
Then, proceed with Scanbody scanning and the position of Dynamic Titanium Base is precisely detected (fig.3)
3
4 5
Cementing process of Titanium Base (fig. 4)
Placing the structure manufactured in CAM over the Titanium Base (fig. 5)
Ask for coming Software
6 *See pag. 2
DYN
AMIC
ABU
TMEN
T 3.
0® S
CREW
S
TPDHST 15 N·cm
TPDH25L67 25 N·cm
TPDH16L78 20 N·cm
TPDH14L52 15 N·cm
TPDH16 20 N·cm
TPDH16L73 20 N·cm
TPDH16L76 20 N·cm
TPDH14L39 15 N·cm
TPDH14 15 N·cm
TPDH16L6 20 N·cm
TPDH2L5 25 N·cm
TPDH2L51 25 N·cm
25 N·cmTPDH18
TPDH18L48 25 N·cm
TPDH18L75 25 N·cm
TPDH2 25 N·cm
TPDH17L71 25 N·cm
TPDH16L84 20 N·cm
TPDH18L65 25 N·cm
TPDH25 25 N·cm
TPDH2L67 25 N·cm
25 N·cmTPDH2L74
TPDH2L82 25 N·cm
TPDH2L90 25 N·cm
TPDH2L65 25 N·cm
TPDH2L6 25 N·cm
TPDH18L80 25 N·cm
DSPDCLH-18/24/32PD: 18/24/32 mm
TPDH2L75 25 N·cm
3.0 DYNAMIC ABUTMENT® SYSTEMFOR CAD-CAM MILLED STRUCTURES
ADITIONALINFORMATION
7*See pag. 2
3.0 DYNAMIC ABUTMENT® SCREWS FOR CAD-CAMRE
FERE
NCE
MET
RIC
TORQ
UE
TOTA
L LE
NG
TH
THRE
AD L
ENG
TH
HEAD
DIA
MET
ER
A LE
NG
TH
B LE
NG
TH
C LE
NG
TH
SETT
LEM
ENT
ANG
LE
THRE
AD E
NTR
Y
CON
NEC
TIO
N
1,4 15 N·cm 3,9 1,8 2,4 2,1 - 1,8 straight - 45º chamfer
Hexalobular 1,70
1,4 15 N·cm 4 1,85 2,3 2 2,78 1,22 conical 30º 45º chamfer
1,4 15 N·cm 4,5 2,3 2,3 2,5 3,28 1,22 conical 30º 45º chamfer
1,4 15 N·cm 5,2 2,9 2,3 3,4 - 1,8 straight - 45º chamfer
1,6 20 N·cm 4,4 2,5 2,3 2,9 - 1,5 straight - Semi-sphere
1,6 20 N·cm 5,9 3 2,3 4,4 - 1,5 straight - Semi-sphere
1,6 20 N·cm 7,3 2,2 2,3 4,87 5,56 1,74 conical 35º 45º chamfer
1,6 20 N·cm 7,6 3,6 2,3 6,1 - 1,5 straight - Semi-sphere
1,6 20 N·cm 7,8 2 2,3 5,36 7,03 0,81 conical 15º 45º chamfer
1,6 20 N·cm 8,4 3,5 2,3 6,8 - 1,6 straight - Semi-sphere
N1-72 25 N·cm 7,1 2,6 2,3 5,56 5,65 1,45 conical 70º 45º chamfer
1,8 25 N·cm 4,4 2,75 2,3 3 - 1,4 straight - Semi-sphere
1,8 25 N·cm 4,8 2,8 2,3 3,22 3,65 1,15 conical 30º Semi-sphere
1,8 25 N·cm 6,5 2,8 2,3 5 - 1,5 straight - Semi-sphere
1,8 25 N·cm 7,5 3,3 2,3 6,1 - 1,4 straight - Semi-sphere
1,8 25 N·cm 8 4 2,3 6,5 - 1,5 straight - 45º chamfer
2 25 N·cm 4,7 3 2,3 3,3 - 1,4 straight - Semi-sphere
2 25 N·cm 5 2,8 2,3 3,39 3,6 1,4 conical 30º Semi-sphere
2 25 N·cm 5,1 3,1 2,3 3,6 - 1,5 straight - Semi-sphere
2 25 N·cm 6 2,7 2,3 4,5 - 1,5 straight - Semi-sphere
2 25 N·cm 6,5 2,7 2,3 5 - 1,5 straight - 45º chamfer
2 25 N·cm 6,7 2,3 2,59 3,65 5,68 1,02 conical 15º 45º chamfer
2 25 N·cm 7,4 3,3 2,3 6 - 1,4 straight - Semi-sphere
2 25 N·cm 7,5 2,75 2,3 5,93 6,18 1,32 conical 35º 45º chamfer
2 25 N·cm 8,2 4,7 2,4 6,7 - 1,5 straight - Semi-sphere
2 25 N·cm 9 4 2,3 7,5 - 1,5 straight - Semi-sphere
2,5 25 N·cm 5,4 3,8 2,85 4,1 - 1,3 straight - Semi-sphere
2,5 25 N·cm 6,7 4,6 2,85 5,1 - 1,6 straight - Semi-sphere
TPDH14L39
TPDH14
TPDHST
TPDH14L52
TPDH16
TPDH16L6
TPDH16L73
TPDH16L76
TPDH16L78
TPDH16L84
TPDH17L71
TPDH18
TPDH18L48
TPDH18L65
TDPH18L75
TPDH18L80
TPDH2
TPDH2L5
TPDH2L51
TPDH2L6
TPDH2L65
TPDH2L67
TPDH2L74
TPDH2L75
TPDH2L82
TPDH2L90
TPDH25
TPDH25L67
8 *See pag. 2
3.0 DYNAMIC TITANIUM BASES TO ANGULATE IN CAD-CAM
COMPATIBLE NOBEL BIOCARE BRANEMARK
SYSTEM
COMPATIBLE NOBEL BIOCARE
MULTIUNIT
COMPATIBLE BTIINTERNAL
CONNECTION
NAR
ROW
PL
ATFO
RMRE
GUL
AR
PLAT
FORM
REG
ULAR
PL
ATFO
RMN
ARRO
W
PLAT
FORM
REG
ULAR
PL
ATFO
RMN
ARRO
W
PLAT
FORM
REG
ULAR
PL
ATFO
RM
TPDH16L6IND3UCS35/TiAIND3UCH35/TiA
TPDH14L39
TPDH18L75IND3RPLR35/TiAIND3RPLT35/TiA
TPDH18L65IND3BTIRRP/TiAIND3BTIHRP/TiA
TPDH2L90IND3RPLR43/TiAIND3RPLT43/TiA
TPDH2L6IND3UCS41/TiAIND3UCH41/TiA
IND3CO41/TiA
TPDH2L75IND3ACTRRP/TiAIND3ACTHRP/TiA
TPDH16L73IND3ACTRNP/TiAIND3ACTHNP/TiA
COMPATIBLE NOBEL BIOCARE BRANEMARK
SYSTEM
COMPATIBLE NOBEL BIOCARE
REPLACE
COMPATIBLE NOBEL BIOCARE
REPLACE
COMPATIBLE NOBEL BIOCARE
ACTIVE
COMPATIBLE NOBEL BIOCARE
ACTIVEREG
ULAR
PL
ATFO
RM
Narrow platform maximum angulation 25°Regular platform maximum angulation 30°
9*See pag. 2
3.0 DYNAMIC TITANIUM BASESTO ANGULATE IN CAD-CAM
REGULAR/
WIDE
PLATFORM
REGULAR
PLATFORM
NARRO
W
PLATFORM
REGULAR
PLATFORM
REGULAR
PLATFORM
NARRO
W
PLATFORM
NARRO
W
PLATFORM
REGULAR
PLATFORM
COMPATIBLE DIO SM IND3DIORRP/TiAIND3DIOHRP/TiA
COMPATIBLE ZIMMER
SCREW-VENT IND3ZIMR35/TiAIND3ZIMH35/TiA
COMPATIBLE ZIMMER
SCREW-VENT IND3ZIMR45/TiAIND3ZIMH45/TiA
COMPATIBLE STRAUMANN
INTERN OCTAGON IND3OCR48/TiAIND3OCO48/TiA
COMPATIBLE STRAUMANNBONE LEVEL IND3BONRNP/TiAIND3BONHNP/TiA
COMPATIBLE STRAUMANNBONE LEVEL IND3BONRRP/TiAIND3BONHRP/TiA
COMPATIBLE ZIMMER
SCREW-VENTWITH FRICTION
IND3ZIOHNP/TiA
IND3ZIOHRP/TiA
Narrow platform maximum angulation 25° Regular platform maximum angulation 30°
COMPATIBLE ZIMMER
SCREW-VENTWITH FRICTION
TPDH2L74
TPDH17L71
TPDH17L71
TPDH2L67
TPDH16L78
TPDH16L78
TPDH17L71
TPDH17L71
10
SCANBODY SBIND3OCRP/PKSBIND3RP/PKSBIND3MURP/PKCompatible Nobel BiocareMulti-unit Regular
Rest of compatibilitesRegular
Compatible with StraumannInternal Regular Octogon
COMPATIBLE ASTRA AQUA TPDH16L76IND3ASTRRP/TiAIND3ASTHRP/TiA
REGU
LAR
PLAT
AFOR
M
SBIND3NP/PKRest of compatibilitesNarrow
Narrow platform maximum angulation 25°Regular platform maximum angulation 30°
3.0 DYNAMIC TITANIUM BASES AND SCAN BODYTO ANGULATE IN CAD-CAM
11
Each and every commercial trademark mentioned on this catalogue are fully registered by their respective companies, the appearing images are just to provide an orientations.Talladium reserves the rigth to modify this document without previous notice.Talladium is not responsible for the adequate execution of this products if the warning indications corresponding to every reference are not contemplated.
AV. BLONDEL, 54 3º25002 LLEIDA (SPAIN)
TEL. +34 973 289 [email protected]
www.dynamicabutment.com
ENG
- e
ditio
n 20
14/1