caddx nx-8

3
Caddx NX-8 Basic Cornmands Zones 8 Hardwired, up to 48 total with zone expanders orWireless Batteries 12 volt rechargeable Gel-Cell inside main panel AC Transformer is 16.5 volts DoorlWindows 4.5 volt Alkaline Motion Sensor 3.6 volt Lithium Smoke Detector 2 9 volt Alkaline Gbutton Keyfob 3.6 volt Lithium Pendant Panic 3.6 volt Lithium Downloadable Yes Partitions Up to 8 Panic Buttons Police, Fire and Auxiliary (not Medical) Arnr AWAY 4 digit code or press EXIT Bufton (EXIT Light turns ON) Arm $TAY 4 digit code + STAY (EXIT, STAY, BYPASS tums ON) Quick Arm Prcss EXIT Button to arm Away, STAY Bufton if arming in Home Mode lnstant Arm Arm system with STAY Button or User Code + STAY and press STAY again Partition Arm Enter User Gode + Partition (1 to 8) (Muliple partitions press t, 2, 3 etc) or Enter User Code + DOWN Arrow Disarm 4 digit code (lf wrong code entered keypad beeps 3 times, try again) Partition Disarm Enter User Code + Partition (1 to 8) + # (Muliple partitions press 1, 2, 3 etc) or Enter User Code + UP Arrow Move to Fartition l. User Code + * + Pafiition (1 to 8) (Display shows status of Partition) 2. Press # to exit back to original Partition Cancel Buttnn Enter Code + CANCEL Button to stop signal to monitoring station Eypass l. Press BYPASS 2. Enter User Code if required (BYPASS Light will Flash) 3. EnterZone to Bypass (1 to 48) 4. Press BYPASS Button again (Bypassed Zone turns ON) 5. Enter next Zone to Bypass or # to exit Group Bypass (lf enabled) BYPASS + 0 + BYPASS (Bypasses several motions) Alarrn Memory Press * + 3, last Alarm will flash, press # to exit E\rent History l. Press * 90 (Keypad prompts for iilaster Code) {LCD Keypadsl 2. Enter Master Code (Keypad shows last event) 3. Press UP and DOWN Arrows to scroll (Down scrolls back through history) 4. Press # to exit Smohe Reset Press * 7 (lf Smoke still sounds power down system, Smoke detector is bad) Door Chimes Press CHIME Button to enable/disable {CHIME light turns ON} System T6st Press * 4 to test Battery, Communicator and/or Siren Change Paltition Press * + 1 + Partition I to 8 (Works for 60 seconds) Setting Time l. Press * + I + 7 + Master Code (Service Light Flashes) 2. Enter 2-digit Hour {01 to 23} 3. Enter 2-digit Minute (01 to 59) (Example: l:30 PM would be entercd as 1330) Setting Date l. Press * + 9 + 6 + Master Code (Service Light Flashes) 2. Enter Day (1 = Sunday to 7 = Saturday) 3. Enter 2 digit Month (01 = January to 12 = December) 4. Enter 2 digit Day (01 to 31) 5. Enter 2 digit Year (2000 = 00) (Example: Sunday January 23rd 2000 would be 1 01 23 00) Keypad Volume L Press * + 0, keypad begins beeping 2, Press UP Arrow key to raise Tone, Down Arrow to lower Tones (lf keypad has no Arrow keys press I to raise Tone, 2 to lower Tone 3. Press # to exit

Upload: baub05

Post on 05-Mar-2015

206 views

Category:

Documents


7 download

TRANSCRIPT

Page 1: Caddx NX-8

Caddx NX-8 Basic Cornmands

Zones 8 Hardwired, up to 48 total with zone expanders orWireless

Batteries 12 volt rechargeable Gel-Cell inside main panelAC Transformer is 16.5 voltsDoorlWindows 4.5 volt AlkalineMotion Sensor 3.6 volt LithiumSmoke Detector 2 9 volt AlkalineGbutton Keyfob 3.6 volt LithiumPendant Panic 3.6 volt Lithium

Downloadable Yes

Partitions Up to 8

Panic Buttons Police, Fire and Auxiliary (not Medical)

Arnr AWAY 4 digit code or press EXIT Bufton (EXIT Light turns ON)

Arm $TAY 4 digit code + STAY (EXIT, STAY, BYPASS tums ON)

Quick Arm Prcss EXIT Button to arm Away, STAY Bufton if arming in Home Mode

lnstant Arm Arm system with STAY Button or User Code + STAY and press STAY again

Partition Arm Enter User Gode + Partition (1 to 8) (Muliple partitions press t, 2, 3 etc)or Enter User Code + DOWN Arrow

Disarm 4 digit code (lf wrong code entered keypad beeps 3 times, try again)

Partition Disarm Enter User Code + Partition (1 to 8) + # (Muliple partitions press 1, 2, 3 etc)or Enter User Code + UP Arrow

Move to Fartition l. User Code + * + Pafiition (1 to 8) (Display shows status of Partition)2. Press # to exit back to original Partition

Cancel Buttnn Enter Code + CANCEL Button to stop signal to monitoring station

Eypass l. Press BYPASS2. Enter User Code if required (BYPASS Light will Flash)3. EnterZone to Bypass (1 to 48)4. Press BYPASS Button again (Bypassed Zone turns ON)5. Enter next Zone to Bypass or # to exit

Group Bypass (lf enabled) BYPASS + 0 + BYPASS (Bypasses several motions)

Alarrn Memory Press * + 3, last Alarm will flash, press # to exit

E\rent History l. Press * 90 (Keypad prompts for iilaster Code){LCD Keypadsl 2. Enter Master Code (Keypad shows last event)

3. Press UP and DOWN Arrows to scroll (Down scrolls back through history)4. Press # to exit

Smohe Reset Press * 7(lf Smoke still sounds power down system, Smoke detector is bad)

Door Chimes Press CHIME Button to enable/disable {CHIME light turns ON}

System T6st Press * 4 to test Battery, Communicator and/or Siren

Change Paltition Press * + 1 + Partition I to 8 (Works for 60 seconds)

Setting Time l. Press * + I + 7 + Master Code (Service Light Flashes)2. Enter 2-digit Hour {01 to 23}3. Enter 2-digit Minute (01 to 59)(Example: l:30 PM would be entercd as 1330)

Setting Date l. Press * + 9 + 6 + Master Code (Service Light Flashes)2. Enter Day (1 = Sunday to 7 = Saturday)3. Enter 2 digit Month (01 = January to 12 = December)4. Enter 2 digit Day (01 to 31)5. Enter 2 digit Year (2000 = 00)(Example: Sunday January 23rd 2000 would be 1 01 23 00)

Keypad Volume L Press * + 0, keypad begins beeping2, Press UP Arrow key to raise Tone, Down Arrow to lower Tones

(lf keypad has no Arrow keys press I to raise Tone, 2 to lower Tone3. Press # to exit

Page 2: Caddx NX-8

Caddx NX-8 Ljser Sodes

Master Code User 01 (lf Master Code is not known see bottom of page)Secondary Gode User 02 to 99Hostage Code Set by lnstaller or downloading

Add Code 1. Press * 5 + Master Code {Ready light will flash)2. Enter User (01 to 99) (Zone lights will/may turn on)3. Enter new User Gode4. Press # to exit (lf needed move to Authority Level below)

Authority 1. Press * 6 + Master Code {Ready light will flash)Level 2. Enter User (0{ to 99}

3. Enter new Authority Level(Zone lights show Authority Level, toggle lights ON or OFF by pressing 1 to 7)

1 = Reselved, do not use2 = Arm Only Code {Babysitter Gode)3 = Arm Only after Closing4 = Master Arm/Disarm (Master Code)5 = Am/Disarm (Standard Secondary Gode)6 = Bypass Zones (Allows bypassing ofzones)7 = Open/Close Reporting (Leave OFF for Residential Accounts)8 = Auxiliary Output Code (Normally leave alone)

4. Press * then # # to save and exit or if partitioned system press * once and see below

Oelete Code 1. Press * 5 + Master Code (Ready light will flash)2. Enter User (0'l to 99) (Zone lights will/may turn on)3.Enter****4. Press # to exit

Master Code 1. Press * + I (STAY/CHIME/EXIT/BYPASSTCANCEL lights will flash)Not Known? 2.9713 (lnstall code) (STAYTCHIME/EXIT/BYPASS/CANCEL lights flash, SERVICE turns ON)

(lf incorrect lnstall code entered STAY/CHIME/EXIT/BYPASS/CANCEL will continue flashing)3. Press 0 + # (STAY CHIME EXIT BYPASS CANCEL, SERVICE, ARMED tums ON)2. Press 43 + #3. Press 4 then * + # (Tums light 4 ON and makes Installer Code a Master Code)4. Press EXIT twice (Exits Programming)5, Now program new Master Code using 9713 as temporary Master Code

Page 3: Caddx NX-8

Caddx NX-8 Trouble DisPlaY

lf Service Light i:s on press * 2

Light I - $ystem Fault {press 'l again}{ = Low Battery2 = Sircn Trouble3 = Panel Box Tamper4 = Zone Expander Power Fault5 = Zone Expander Low Battery6 = Zone Expander Tamper7 = Zone Expander lnternal TroubleI -- Ground Fault

Light 2 - Zane Tarnper, press 2 to show zoneLight 3 - Zone Lorr Bafrery, prest 3 to shonr zoneLight 4 - Zone Loss of Suprvision, pfiess 4 to show zoneLight 5 - Zone Trouble, p'ness 5 to show zoneLight 6 - Telephone Line TroubleLight 7 - Failurc to CommunicateLight I - Loes sf Internal Sysbm Time

Prss # to exit