Features • Specifically designed for FT-IR & CD/VCD spectroscopy of biological molecules -1 Useable spectral range 67,000 - 1,000cm Ideal for aqueous solutions Uses small micro-liter volumes Large optical aperture Wide range of path lengths: ~2 to 7, ~10, ~20 , ~40 , ~80 and ~120 m m 5 mm thickness x 50 mm diameter standard size. Cells with 4 mm x 40 mm dimensions are available Matched pairs of cells for sample and reference may be requested Two choices of temperature controllers CaF cells for IR/CD spetroscopy 2 50 mm CaF 2 TM CaF 2 The CaF cell for IR/UV-CD spectroscopy is created 2 between a perfectly flat, optically clear plate and another plate, the center of which is deepened to form a recessed parallel surface surrounded by a groove. This groove serves as a barrier between the sample area and the outer seal, keeping the sample from readily coming into contact with the sealing area. The seal is created by the "upper" flat plate pressing onto the outer ring of the "lower"plate. The cells are very easily assembled and disassembled, filled with solution, and washed between measurements. The seal of the cell prevents the evaporation of water for about 24 h at room temperature in the desiccated area of the FT-IR spectrometer. The reproducibility of the cell path length after assembly / disassembly is 0.1 mm

Upload: others

Post on 08-Sep-2019

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CaF2 cells for IR/CD spetroscopy - RK Tech · Features • Specifically designed for FT-IR & CD/VCD spectroscopy of biological molecules • Useable spectral range 67,000 - 1,000cm-1

Features

• Specifically designed for FT-IR & CD/VCD spectroscopy of biological molecules

-1• Useable spectral range 67,000 - 1,000cm

• Ideal for aqueous solutions

• Uses small micro-liter volumes

• Large optical aperture

• Wide range of path lengths: ~2 to 7, ~10, ~20 , ~40 , ~80 and ~120 m m

• 5 mm thickness x 50 mm diameter standard size. Cells with 4 mm x 40 mm dimensions are available

• Matched pairs of cells for sample and reference may be requested

• Two choices of temperature controllers

CaF cells for IR/CD spetroscopy2

50 mm

CaF2

TM

CaF2

The CaF cell for IR/UV-CD spectroscopy is created 2

between a perfectly flat, optically clear plate and another plate, the center of which is deepened to form a recessed parallel surface surrounded by a groove. This groove serves as a barrier between the sample area and the outer seal, keeping the sample from readily coming into contact with the sealing area. The seal is created by the "upper" flat plate pressing onto the outer ring of the "lower"plate.

The cel ls are ver y easi ly assembled and disassembled, filled with solution, and washed between measurements. The seal of the cell prevents the evaporation of water for about 24 h at room temperature in the desiccated area of the FT-IR spectrometer. The reproducibility of the cell path length after assembly / disassembly is 0.1 mm

Page 2: CaF2 cells for IR/CD spetroscopy - RK Tech · Features • Specifically designed for FT-IR & CD/VCD spectroscopy of biological molecules • Useable spectral range 67,000 - 1,000cm-1

17546 Bee Line Hwy. Jupiter, FL 33458

Office: (561)625-0133 Fax: (561) 625-0717

Toll Free: (866) btools1 E-mail: [email protected]

Website: www.btools.com

TMTempConPelltier based temperature controller

Temperature Control Options

8070605040302010 0-10

8070605040302010 0-10

0 20 40 60 80 100 0 20 40 60 80 100

Tem

pera

ture

(de

g C

)

Tem

pera

ture

(de

g C

)

Time (min)Time (min)

Set 50 °C

Set 0 °C

Set -15 °CSet 80 °C

Set 20 °CSet 20 °C

Features

• Aluminum construction• Threaded for tight seals• High quality, low cost option for temperature control

BioJackTM

Jacketed cell holder

TempConTM temperature controller unit is designed for use in FT-IR spectrometers with two types of windows: large circular BioCellTM windows and rectangular windows. The controller can be controlled either manually or through computer interface. The Ramp-Soak Control Interface allows for temperature studies that can be aligned with FT-IR scanning software and can be used in applications such as effect of temperature on protein conformation.

Features • Typical temperature range: -20.00 °C to +80.00 °C • Temperature range achievable with other coolants -50.00 °C to +100.00 °C • Variable temperature ramp programmable from 0 to 9995 °C / hour • Soak time programmable from 0 to 144 0 minutes • Accepts both BioCellTM and long-rectangle type windows • Custom made holders can be ordered for non-typical window designs BioJackTM liquid cooling and heating jacket is designed for use with the BioCellTM windows for use in FT-IR spectrometers.