calibration of the gravitational wave signal in the ligo detectors gabriela gonzalez (lsu), mike...

25
Calibration of the gravi Calibration of the gravi tational tational wave signal in the wave signal in the LIGO detectors LIGO detectors Gabriela Gonzalez (LSU), Mike Landry (LIGO-LHO), Patrick Sutton (PSU) with the calibration team: Rana Adhikari (LIGO-MIT), Brian O’Reilly (LIGO-LLO), and many others…

Upload: marley-bonson

Post on 14-Dec-2015

213 views

Category:

Documents


0 download

TRANSCRIPT

  • Slide 1

Calibration of the gravitational wave signal in the LIGO detectors Gabriela Gonzalez (LSU), Mike Landry (LIGO-LHO), Patrick Sutton (PSU) with the calibration team: Rana Adhikari (LIGO-MIT), Brian OReilly (LIGO-LLO), and many others Slide 2 Gravitational Wave Signal Originates in a photodetector at the antisymmetric port. It is a demodulated photocurrent: (L1,H1,H2):LSC-AS_Q It is proportional to the differential length of the arm cavities, and thus the gw strain. In the frequency domain, AS_Q(f)=C(f)h(f) C(f): calibration function (complex) Slide 3 Detector control system Gravitational wave strain: h=X ext /L Detected signal: H(f)=open loop gain=G(f)A(f)C(f) interferometer digital filters pendulum calibration Slide 4 Calibrated spectrum Calibration lines Slide 5 Open Loop Gain: Fits Simulink model (R. Adhikari) Slide 6 Open Loop Gain: Fits Parameters in the fit: - Time delays - Optical gain Slide 7 Changing optical gain =scale factor for open loop gain Slide 8 Changing optical gain Slide 9 Scale factor for open loop gain Slide 10 Scale factor for Open Loop Gain Slide 11 Interferometer sensitivity and alignment Carrier power in the arm cavities Sideband Power in the recycling cavity Signal carrier x sideband Slide 12 Changing optical gain Slide 13 LIGO Autocalibrator Tcl script to expedite calibration Calls to DTT (ifo transfer function, psd estimate), Root and/or Matlab manipulation Output (web-navigable) data in ascii, xml, pdf (transfer functions, noise data, olg, sensing functions) Pole-zero fitting useful for rapid commissioning New version interpolates TF, no fits Slide 14 Autocalibrator vs S1 analyses Slide 15 V2 Autocalibrator Latest version does Interpolation of transfer Function (no fit problems) Not as flexible for Commissioning Adding matlab fit and DTT cal record shortly Slide 16 Autocalibrator for S2 S2 run ~per day per ifo In addition to noise curves, output open loop gain and sensing function as a check on point calibration/alpha propagation method Brian OReilly has version running at LLO Slide 17 online resources online resources include the calibration homepage http://blue.ligo-wa.caltech.edu/engrun/Calib_Home/ history (ascii strain and displacement vs time, elog pointers) commissioning (online autocalibration automatic storage of data) science (S1) and engineering (E2-E9) runs And the official page on LIGO sensitivity http://www.ligo.caltech.edu/~lazz/distribution/LSC_Data/ Slide 18 E9 & S2 Calibrations from SenseMonitor SenseMonitor: A DMT program which provides real-time estimates of the average range to which an IFO is sensitive with SNR > 8 to the inspiral of a 1.4-1.4M o neutron-star binary. Runs continuously at LLO, LHO. Tracks the response function of the IFO to make its range estimate, therefore is a natural tool for providing near-real-time calibration information. Slide 19 What SenseMonitor Needs Reference calibration information supplied to SenseMonitor: Measured/modelled open-loop gain H(f) and sensing function C(f) of the IFO, supplied in ASCII data files. RMS amplitude of the 1kHz calibration line in AS_Q during calibration run. Injected amplitude of the 1kHz calibration line in EXC during calibration run. Digital gain (`GW_K' during S1) during calibration run. Slide 20 What SenseMonitor Gives For each 60 sec of AS_Q data, SenseMonitor: measures the current amplitude of the 1kHz calibration line. using the current line amplitude and the reference data, computes the new value of calibration parameter ` '. exports , , range data to DMTViewer. Once per hour: exports , , range data to trend frames. Slide 21 at start 1/minute SenseMonitor ampl AS_Q = 0.00160 ampl EXC = 0.25 beta = 1.0 H(f), C(f): 3.00e1 5.28e+0 4.47e+0... 2.00e3 2.45e-1 2.13e-2 Reference Calibration: AS_Q Data: 1/minute 1/hour , range,... Trend frames: , range,... DMTViewer: Slide 22 Slide 23 Slide 24 Caveats Up to 1-hour latency in writing trend frames. Reference calibration data (open loop gain, sensing function, etc.) not available in trend frames. Calibration lines are not robust (sometimes crash); alpha is not updated if the line amplitude is 150% nominal. Alpha, beta set to zero if IFO is not locked in common mode. Slide 25 Expectations for S2 Good models Frequent checks (autocalibrators) Automatic on-line calibration and reach measurement (SenseMon)