calpeda control panel
DESCRIPTION
Calpeda controlo panel: a biref tutorialTRANSCRIPT
![Page 1: Calpeda control panel](https://reader034.vdocument.in/reader034/viewer/2022052201/5583e3ccd8b42a2a4d8b4614/html5/thumbnails/1.jpg)
CALPEDA!TUTORIAL
![Page 2: Calpeda control panel](https://reader034.vdocument.in/reader034/viewer/2022052201/5583e3ccd8b42a2a4d8b4614/html5/thumbnails/2.jpg)
POWER ONPRESENZA RETE
FAILURE
MP 2000
AVARIA SISTEMA
NO WATERMANCANZA ACQUA
STOP
MAN
AUT
P2
STOP
MANRESET
AUT
P1CONTROL !PANELSpractice guide
![Page 3: Calpeda control panel](https://reader034.vdocument.in/reader034/viewer/2022052201/5583e3ccd8b42a2a4d8b4614/html5/thumbnails/3.jpg)
SELECTION MENU
![Page 4: Calpeda control panel](https://reader034.vdocument.in/reader034/viewer/2022052201/5583e3ccd8b42a2a4d8b4614/html5/thumbnails/4.jpg)
INSTALLATION
IGNITION
OPERATING MODE
STANDARD EMERGENCY TIMED
HOW TO CHANGE OPERATING MODE
STANDARD EMERGENCY TIMED
![Page 5: Calpeda control panel](https://reader034.vdocument.in/reader034/viewer/2022052201/5583e3ccd8b42a2a4d8b4614/html5/thumbnails/5.jpg)
INSTALLATION
![Page 6: Calpeda control panel](https://reader034.vdocument.in/reader034/viewer/2022052201/5583e3ccd8b42a2a4d8b4614/html5/thumbnails/6.jpg)
During installation do not damage the electronic cards and the other electrical components found inside of the box.Provide for enough space all around the control panel for natural cooling. !Do not install the control panel in places exposed to direct sunlight or near sources of heat. !!
1. INSTALLATION
selection menu
![Page 7: Calpeda control panel](https://reader034.vdocument.in/reader034/viewer/2022052201/5583e3ccd8b42a2a4d8b4614/html5/thumbnails/7.jpg)
IGNITION
![Page 8: Calpeda control panel](https://reader034.vdocument.in/reader034/viewer/2022052201/5583e3ccd8b42a2a4d8b4614/html5/thumbnails/8.jpg)
1. IGNITION
OFF
ON
OFF
ON
selection menu
next (2.ignition)
![Page 9: Calpeda control panel](https://reader034.vdocument.in/reader034/viewer/2022052201/5583e3ccd8b42a2a4d8b4614/html5/thumbnails/9.jpg)
POWER ONPRESENZA RETE
FAILURE
MP 2000
AVARIA SISTEMA
NO WATERMANCANZA ACQUA
STOP
MAN
AUT
P2
STOP
MANRESET
AUT
P1
Firstly activate the pumps pushing the AUT/STOP bottoms
POWER ONPRESENZA RETE
FAILURE
MP 2000
AVARIA SISTEMA
NO WATERMANCANZA ACQUA
STOP
MAN
AUT
P2
STOP
MANRESET
AUT
P1
AUTSTOP
2. IGNITION
selection menu
next (3.ignition)
![Page 10: Calpeda control panel](https://reader034.vdocument.in/reader034/viewer/2022052201/5583e3ccd8b42a2a4d8b4614/html5/thumbnails/10.jpg)
With a three-pashe motor check that the direction of rotation is as shown by the arrow on the pump casing, otherwise disconnect electrical power and reverse the connections of two phase.
!
selection menu
3. IGNITION
![Page 11: Calpeda control panel](https://reader034.vdocument.in/reader034/viewer/2022052201/5583e3ccd8b42a2a4d8b4614/html5/thumbnails/11.jpg)
OPERATING MODE
![Page 12: Calpeda control panel](https://reader034.vdocument.in/reader034/viewer/2022052201/5583e3ccd8b42a2a4d8b4614/html5/thumbnails/12.jpg)
TIMED3 EMERGENCY2
STANDARD1OPERATING MODE
selection menu
![Page 13: Calpeda control panel](https://reader034.vdocument.in/reader034/viewer/2022052201/5583e3ccd8b42a2a4d8b4614/html5/thumbnails/13.jpg)
Each phase of the set operation is controlled by a electronic card that provides the following functions: • pump stop when there no water in the suction. • avoid pump starting in case of water hammering. • alarm activation when air cushion in the tanks drop. • pump stop when air cushion is over. • pump stop with too close starts and stops. !Flashing FAILURE red led: • insufficient air cushion in the tank. Continuous FAILURE red led: • Pump stopped when there is no air cushion in the tank.
1. STANDARD MODE
selection menu
![Page 14: Calpeda control panel](https://reader034.vdocument.in/reader034/viewer/2022052201/5583e3ccd8b42a2a4d8b4614/html5/thumbnails/14.jpg)
ALARM TIME SETTING!
With the trimmer placed in the back side of the electronic card, it is possible to select a certain time to detect the drop of air cushion in the tanks, due to the membrane failure. !Example: 4 sec set delay time When the delay time between two following signals of the pressure switches is lower than 4 sec., the alarm for insufficient air cushion is detected. If the failure is not repaired, when the delay between the two following signals reaches 2 sec. (half the alarm time), the set stops (continuous FAILURE red led).After having the tanks repaired, reset the operation by pushing RESET pushbutton. !!!!
selection menu
next
![Page 15: Calpeda control panel](https://reader034.vdocument.in/reader034/viewer/2022052201/5583e3ccd8b42a2a4d8b4614/html5/thumbnails/15.jpg)
!
POWER ONPRESENZA RETE
FAILURE
MP 2000
AVARIA SISTEMA
NO WATERMANCANZA ACQUA
STOP
MAN
AUT
P2
STOP
MANRESET
AUT
P1POWER ONPRESENZA RETE
FAILURE
MP 2000
AVARIA SISTEMA
NO WATERMANCANZA ACQUA
STOP
MAN
AUT
P2
STOP
MANRESET
AUT
P1
Flashing FAILURE red led
Pre-alarm. Insufficient air cushion in
the tank
Continuous FAILURE red led
Alarm! Pump stopped when there is no air
cushion in the tank
The flashing or continuous FAILURE red led switches off only by pushing RESET pushbutton.
RESET
selection menu
![Page 16: Calpeda control panel](https://reader034.vdocument.in/reader034/viewer/2022052201/5583e3ccd8b42a2a4d8b4614/html5/thumbnails/16.jpg)
2. EMERGENCY MODE!The operating mode is the same as the one described above with the only difference that the pump do not stop if there is no air cushion, but continue to run with starts and stops at intervals of a few seconds to ensure water supply also in emergency cases.
This mode must be used only in case of an emergency for short periods of time. The tank's air cushion must be restored as soon as possible. Prolonged operating in these conditions can lead to the burning of the electric motors and to the damaging of the contacts of the electromagnetic switches.
!
selection menu
![Page 17: Calpeda control panel](https://reader034.vdocument.in/reader034/viewer/2022052201/5583e3ccd8b42a2a4d8b4614/html5/thumbnails/17.jpg)
3. TIMED MODE!
It is recommended to use operating mode 3 only with pump with a flat curve, as the pump may continue to run also with a zero flow rate.!
The back side of the electronic card features a TRIMMER with a scale ranging from 3 to 24 for setting the minimum running time for the pump.
3 4 9 13 18 22 24
30 minuti 40 m 90 m 130 m 180 m 220 m 240 m
Trimmer selection
Working time
selection menu
next
![Page 18: Calpeda control panel](https://reader034.vdocument.in/reader034/viewer/2022052201/5583e3ccd8b42a2a4d8b4614/html5/thumbnails/18.jpg)
HOW TO CHANGE OPERATING MODE
![Page 19: Calpeda control panel](https://reader034.vdocument.in/reader034/viewer/2022052201/5583e3ccd8b42a2a4d8b4614/html5/thumbnails/19.jpg)
By default the control panel is set in the standard mode
selection menu
![Page 20: Calpeda control panel](https://reader034.vdocument.in/reader034/viewer/2022052201/5583e3ccd8b42a2a4d8b4614/html5/thumbnails/20.jpg)
TIMED3 EMERGENCY2
STANDARD1
selection menu
OPERATING MODE
![Page 21: Calpeda control panel](https://reader034.vdocument.in/reader034/viewer/2022052201/5583e3ccd8b42a2a4d8b4614/html5/thumbnails/21.jpg)
STANDARD MODE
OFF
ON
OFF
ON
POWER ONPRESENZA RETE
FAILURE
MP 2000
AVARIA SISTEMA
NO WATERMANCANZA ACQUA
STOP
MAN
AUT
P2
STOP
MANRESET
AUT
P1 1. Hold the AUT/STOP button down
AUTSTOP
2. Switch on (holding the AUT/STOP button down)
selection menu
next
![Page 22: Calpeda control panel](https://reader034.vdocument.in/reader034/viewer/2022052201/5583e3ccd8b42a2a4d8b4614/html5/thumbnails/22.jpg)
FUNZIONAMENTO STANDARD
3. Wait until the flashing failure led flashes once
POWER ONPRESENZA RETE
FAILURE
MP 2000
AVARIA SISTEMA
NO WATERMANCANZA ACQUA
STOP
MAN
AUT
P2
STOP
MANRESET
AUT
P1
Release after the flash!selection menu
![Page 23: Calpeda control panel](https://reader034.vdocument.in/reader034/viewer/2022052201/5583e3ccd8b42a2a4d8b4614/html5/thumbnails/23.jpg)
EMERGENCY MODE
OFF
ON
OFF
ON
POWER ONPRESENZA RETE
FAILURE
MP 2000
AVARIA SISTEMA
NO WATERMANCANZA ACQUA
STOP
MAN
AUT
P2
STOP
MANRESET
AUT
P1
AUTSTOP
selection menu
1. Hold the AUT/STOP button down
next
2. Switch on (holding the AUT/STOP button down)
![Page 24: Calpeda control panel](https://reader034.vdocument.in/reader034/viewer/2022052201/5583e3ccd8b42a2a4d8b4614/html5/thumbnails/24.jpg)
POWER ONPRESENZA RETE
FAILURE
MP 2000
AVARIA SISTEMA
NO WATERMANCANZA ACQUA
STOP
MAN
AUT
P2
STOP
MANRESET
AUT
P1
!selection menu
EMERGENCY MODE
3. Wait until the flashing failure led flashes twice
Release after the flash
![Page 25: Calpeda control panel](https://reader034.vdocument.in/reader034/viewer/2022052201/5583e3ccd8b42a2a4d8b4614/html5/thumbnails/25.jpg)
TIMED MODE
OFF
ON
OFF
ON
POWER ONPRESENZA RETE
FAILURE
MP 2000
AVARIA SISTEMA
NO WATERMANCANZA ACQUA
STOP
MAN
AUT
P2
STOP
MANRESET
AUT
P1
AUTSTOP
selection menu
1. Hold the AUT/STOP button down
next
2. Switch on (holding the AUT/STOP button down)
![Page 26: Calpeda control panel](https://reader034.vdocument.in/reader034/viewer/2022052201/5583e3ccd8b42a2a4d8b4614/html5/thumbnails/26.jpg)
TIMED MODE
POWER ONPRESENZA RETE
FAILURE
MP 2000
AVARIA SISTEMA
NO WATERMANCANZA ACQUA
STOP
MAN
AUT
P2
STOP
MANRESET
AUT
P1
!selection menu
3. Wait until the flashing failure led flashes thrice
Release after the flash
![Page 27: Calpeda control panel](https://reader034.vdocument.in/reader034/viewer/2022052201/5583e3ccd8b42a2a4d8b4614/html5/thumbnails/27.jpg)