cam lact data sheet

4
CAM-LACT Lease Automatic Custody Transfer Units 2” and 3” units in stock and ready to ship When dependable lease automatic custody transfer (LACT) equipment is required, Cameron’s CAM-LACT units are in stock and ready to ship. These quick-delivery units feature the same high-quality materials and durable construction as our custom-order units, but are prefabricated to meet customer needs without the wait. Cameron’s CAM-LACT design, which includes Cameron’s LINCO temperature averager, is available in 2” and 3” pipeline sizes. For more than 50 years, customers have trusted Cameron’s LINCO products for custody transfer of crude oil and petroleum products for automatic measurement, sampling, and transfer of oil from production sites to trucks, pipelines or storage tanks. Today, our LINCO product line offers one of the highest levels of measurement expertise in the industry. Our experienced team is ready to serve you, not only with equipment selection, but with installation, operation and maintenance support for the life of your equipment. Contact Cameron today to discuss your measurement and control needs and determine if the CAM-LACT unit is right for you. TECHNICAL SPECIFICATIONS

Upload: yana-parravano

Post on 09-Dec-2015

260 views

Category:

Documents


4 download

DESCRIPTION

Hoja de datos

TRANSCRIPT

Page 1: Cam Lact Data Sheet

CAM-LACT Lease Automatic Custody Transfer Units2” and 3” units in stock and ready to ship

When dependable lease automatic custody transfer (LACT)

equipment is required, Cameron’s CAM-LACT™ units are in stock

and ready to ship. These quick-delivery units feature the same

high-quality materials and durable construction as our custom-order

units, but are prefabricated to meet customer needs without the

wait. Cameron’s CAM-LACT design, which includes Cameron’s

LINCO™ temperature averager, is available in 2” and 3” pipeline sizes.

For more than 50 years, customers have trusted Cameron’s LINCO

products for custody transfer of crude oil and petroleum products

for automatic measurement, sampling, and transfer of oil from

production sites to trucks, pipelines or storage tanks. Today, our

LINCO product line offers one of the highest levels of measurement

expertise in the industry. Our experienced team is ready to serve

you, not only with equipment selection, but with installation,

operation and maintenance support for the life of your equipment.

Contact Cameron today to discuss your measurement and control

needs and determine if the CAM-LACT unit is right for you.

TECHNICAL SPECIFICATIONS

Page 2: Cam Lact Data Sheet

General Specifications

• 6 ft x 12 ft structural steel skid with a welded

containment lip, drain and a solid floor

• Designed to ANSI 150 class

• Hydrostatically tested at 1.5 times the

maximum allowable working pressure

• Welded and flanged fittings manufactured in

accordance with industry standards:

Pipe – ASTM A106, Grade B

Flanges – ASTM A105

Fittings – ASTM A234

• All piping and structural steel is sand-blasted, primered and coated with “desert tan” epoxy topcoat. A white topcoat is optional (see CAM-LACT Options, page 4, for details)

• Inlet ball valve with carbon steel body,

standard trim, and manual lever operator

• Nominal flow rates:

2” LACT: 150 bbl/hr (105 gal/min)

3” LACT: 360 bbl/hr (252 gal/min)

• Shipping weight is approximately 3500 lb

Centrifugal Charge Pump

• 15-hp, 3600-rpm, three-phase, 480-V

TEFC electric motor

Strainer

• Strainer with four-mesh strainer basket

• Differential pressure gauge, 0 to 15 psi, 2.5” face

Air eliminator

• 3/4” x 1/2” NPT, 316 stainless steel air eliminator

• 3/4” NPT stainless steel check valve

BS&W Probe

• In-line BS&W capacitance probe

Sampling equipment

• LINCO Model 3-2 V static mixer with flow-

straightening vane

• LINCO Model VR-10C-100 impulse actuated sampler

with 0 to 7 cc adjustable sample volume

• Manual sample drawoff assembly

Sample receiver

• 15-gal LINCO Model 15F steel sample container

35 psig maximum working pressure at 100° F

Internal spray bar

Charge pump

Air eliminator

Sample receiver

2

Page 3: Cam Lact Data Sheet

Quick-opening top closure

Cast iron centrifugal pump designed for a flow

rate of 15 gal/min at a discharge pressure of

33 psig

3/4-hp, 3600-rpm, single-phase, 60- Hz,

115-VAC TEFC electrical motor

Pressure gauge, 2-1/2” face, 0 to 30 psig

divert Valve

• Three-way divert valve with electric actuator

Meter

• Double-case steel positive displacement liquid

meter with 150# ANSI flanged connections rated

for 150 psig maximum working pressure

• Flow ranges (meter only)

2” meter: 17 to 150 gal/min

3” meter: 50 to 500 gal/min

For LACT system flow ranges, see General

Specifications, page 2

• Accessories (included)

100% 5:1 gearing and dummy calibrator

Right-angle drive for meter proving

Counter with micro switch

Thermistor temperature probe

3/4” NPT stainless steel drain ball valve,

stainless steel body and standard trim with

manual lever operator

instrument Spool

• Stainless steel test thermowell

• Three pressure gauge assemblies, 2-1/2” face, 0

to 200 psig (top of loop, downstream on loop and

after meter)

Prover Loop

• Flanged meter prover manifold assembly

In-line double block-and-bleed valve with

tattle-tale manual body bleed valve and

differential thermal relief with manual operator

Isolating ball valves, carbon steel body and

manual lever operator

Two NPT bronze quick connections

Two 1/2” stainless steel prover loop drain valves

Fabricated sump box with removable lid

Valves

• Two self-contained diaphragm-operated

backpressure control valves (one for sales line

outlet and one for divert line)

External pressure sensing line (100 psig

maximum operating pressure)

316 stainless steel removable trim

316 stainless steel with nylon-reinforced

Buna-N plug and adjustable spring with range

of 20 to 150 psig

• Flanged swing check valve, carbon steel body, 316

stainless steel trim with bolted bonnet

• Outlet ball valve with carbon steel body, standard

trim and manual lever operator

electrical

• LACT control panel mounted on stand

Class I, Div. 2 pump control panel to include

PLC for LACT control and operation

Transformer, Class I, Div. 2, 480 VAC to

120 VAC

LINCO Model TA-500 temperature averager

and BS&W monitor

Component wiring and conduit connects to

skid-mounted Class I, Div. 2 junction box

Divert valve

Meter

Prover loop

Backpressure valve

Control panel

3

Page 4: Cam Lact Data Sheet

6 ft

12 ft

7 ft, 8 in.

17 in.24.5 in.

CAM-LACT – TOP VIEW

CAM-LACT – SIDE VIEW

6 ft

12 ft

7 ft, 8 in.

17 in.24.5 in.

CAM-LACT – TOP VIEW

CAM-LACT – SIDE VIEW

CAM-LACT Options

• Large numeral counter

• Large numeral counter with preset

• Large numeral counter with preset

and printer

• VR-15 high-volume sampler

• TA-1000 temperature averager

• TA-1000 temperature averager with

Modbus® communications

• Counter with proximity switch

(explosion-proof)

• White topcoat (allow one week for

delivery)

Training and Support

Cameron offers expert customer training

for LACT operation and maintenance and a

full range of onsite contracted field services.

Call us for assistance with

• Startup and commissioning

• Onsite liquid meter proving and

calibration

• Troubleshooting

• Field maintenance at system and

component level

• Component repair and/or replacement

ALGERIA • C ANADA • CHINA • INDIA • MAL AYSIA • RUSSIA • UAE • UK • USA www.c-a-m.com/measurement

© 2013 Cameron | CAM-LACT and LINCO are trademarks of Cameron. Modbus is a registered trademark of the Modbus Organization, Inc. | SWP 2M, 10/13, AD01131M

NOrTh ANd SOuTh AMeriCA

14450 JFK Blvd.

Houston, TX 77032

USA

Tel 1 281 582 9500

[email protected]

Contact usFor more information on CAM-LACT units or Cameron’s custom-designed LACT equipment, call or email us today.1 432 561 9822 • [email protected]