Page 1: CAPILLARY ELECTROPHORESIS SYSTEMS CAPEL CAPILLARY ELECTROPHORESIS SYSTEMS CAPEL CERTIFICATION Simultaneous quantitative determination of several components

CAPILLARY ELECTROPHORESIS CAPILLARY ELECTROPHORESIS SYSTEMSSYSTEMS

CAPELCAPEL

Page 2: CAPILLARY ELECTROPHORESIS SYSTEMS CAPEL CAPILLARY ELECTROPHORESIS SYSTEMS CAPEL CERTIFICATION Simultaneous quantitative determination of several components

CAPILLARY ELECTROPHORESIS SYSTEMSCAPILLARY ELECTROPHORESIS SYSTEMS

CAPELCAPEL

CERTIFICATIONCERTIFICATION

Simultaneous quantitative Simultaneous quantitative determination of several determination of several components in a complex components in a complex mixturemixture

Page 3: CAPILLARY ELECTROPHORESIS SYSTEMS CAPEL CAPILLARY ELECTROPHORESIS SYSTEMS CAPEL CERTIFICATION Simultaneous quantitative determination of several components

ADVANTAGEADVANTAGESSCAPEL-SERIESCAPEL-SERIES

High separation efficiency Low reagent consumption Simple sample preparation Compact benchtop design Autosamplers (10 inlet and and 10 outlet

vials) in CAPEL-104, CAPEL-104T, and CAPEL-105

Implementation of various methods (Capillary Zone Electrophoresis, Micellar electrokinetic chromatography, Capillaryisoelectric focusing, capillary gel electrophoresis, capillary isotachophoresis)

Page 4: CAPILLARY ELECTROPHORESIS SYSTEMS CAPEL CAPILLARY ELECTROPHORESIS SYSTEMS CAPEL CERTIFICATION Simultaneous quantitative determination of several components

ELECTROOSMOTIC FLOW (EOF)ELECTROOSMOTIC FLOW (EOF)

R – Si-OH R – Si-O- + H+

K+

A-

EOF

+ _

pH > 3.0

Both anions and cations can be analysed in one run

Page 5: CAPILLARY ELECTROPHORESIS SYSTEMS CAPEL CAPILLARY ELECTROPHORESIS SYSTEMS CAPEL CERTIFICATION Simultaneous quantitative determination of several components

BASIC FEATURESBASIC FEATURES

CAPEL-103Р, 103РТ

CAPEL-104, 104Т

CAPEL-105

• wavelength 254 nm• autosampler• liquid cooling (model 104Т)

• wavelength 254 nm• manual operation mode• liquid cooling (model 103РТ)

• wavelength 190-380 nm• autosampler• liquid cooling

Page 6: CAPILLARY ELECTROPHORESIS SYSTEMS CAPEL CAPILLARY ELECTROPHORESIS SYSTEMS CAPEL CERTIFICATION Simultaneous quantitative determination of several components

MAJOR APPLICATIONSMAJOR APPLICATIONS

pesticides inorganic ions phenols

Environment Pharmacology

medicines formulations pharmacokinetics

Food

preservatives dyes target compounds, etc.

Clinical diagnostics proteomics DNA / RNA affinity studies immunoanalyses

Forensic Investigations drugs explosives lethal markers, etc.

Chemical industry

Page 7: CAPILLARY ELECTROPHORESIS SYSTEMS CAPEL CAPILLARY ELECTROPHORESIS SYSTEMS CAPEL CERTIFICATION Simultaneous quantitative determination of several components

ANALYSIS OF PSYCHOTROPIC ANALYSIS OF PSYCHOTROPIC DRUGSDRUGS

2 3 4 5 6 7

0

5

10

15

Marziali et al., Fig. 3 top

CBZ

EP-CBZ

10,11OH-CBZ

EOF

abso

rban

ce [m

AU

]

time [min]

4 6 8 10 12 14 160

1

2

3

4

Marziali et al, Fig.4, top

EOF

10OH-CBZ

abso

rban

ce [m

AU

]

time [min]

MECK separation of carbamazepine and its main

metabolites

Chiral separation of carbamazepine metabolite

Page 8: CAPILLARY ELECTROPHORESIS SYSTEMS CAPEL CAPILLARY ELECTROPHORESIS SYSTEMS CAPEL CERTIFICATION Simultaneous quantitative determination of several components

ANALYSIS OF ANTIEPILEPTIC ANALYSIS OF ANTIEPILEPTIC DRUGSDRUGS

3 7 10 130,0

0,2

0,4

0,6

0,8

phe

no

ba

rbita

l

carb

am

aze

pin

e

lam

otr

igin

e

phe

nyt

oin

prim

ido

ne

leve

tira

ceta

mD

MS

O

1-butanol

mA

U

time (min)

3 7 10 130,0

0,2

0,4

0,6

0,8

carb

am

aze

pin

e

lam

otr

igin

e

ph

en

ytoin

ph

en

ob

arb

ital

pri

mid

one

leve

tira

ceta

mD

MS

O

1-propanol

mA

U

time (min)

Microemulsion EKC of 6 closely related antiepileptic drugs

Selectivity changes are seen with different organic modifiers

Page 9: CAPILLARY ELECTROPHORESIS SYSTEMS CAPEL CAPILLARY ELECTROPHORESIS SYSTEMS CAPEL CERTIFICATION Simultaneous quantitative determination of several components

2 4 6 8 min

mAU

ANALYSIS OF WATER – SOLUBLE ANALYSIS OF WATER – SOLUBLE VITAMINSVITAMINS

Buffer 0.01M borate, pH 9.8Sample standard solution of vitaminsCapillary l/L 50/60 cm, id 75 µmInjection 600 mbar*sVoltage +20 kVDetection 254 nm

1 – vitamin В1

2 – vitamin В12

3 – vitamin В2

4 – vitamin В6

5 – ascorbic acid

6 – nicotinic acid

7 – folic acid

Page 10: CAPILLARY ELECTROPHORESIS SYSTEMS CAPEL CAPILLARY ELECTROPHORESIS SYSTEMS CAPEL CERTIFICATION Simultaneous quantitative determination of several components

ANALYSIS OF MEDICALLY RELEVANT ANALYSIS OF MEDICALLY RELEVANT PEPTIDESPEPTIDES

5 6 7 8 9 10 11 12 min

1.7 mAU

A

1

2

3

4

1-antithrombine

2-bradikinine

3-angiotensin I

4-angiotensine II

Buffer 10 mM phosphate, pH 2.5Capillary 26 / 35 cm, 50µm IDInjection 150 mbar x secVoltage 25 kVSample 10 µg/mL each

Page 11: CAPILLARY ELECTROPHORESIS SYSTEMS CAPEL CAPILLARY ELECTROPHORESIS SYSTEMS CAPEL CERTIFICATION Simultaneous quantitative determination of several components

ANALYSIS OF THE CATION COMPOSITION OF ANALYSIS OF THE CATION COMPOSITION OF THE PORTABLE, NATURAL AND WASTE THE PORTABLE, NATURAL AND WASTE

WATERWATER

Buffer 6 mmol benzimidazole, 2.5 mmol tartaric acid, 2.0 mmol 18-crown-6Sample calibration solutionCapillary l/L 50/60 cm, id 75 µmInjection 150 mbar*sVoltage +10 kVDetection 254 nm, indirect

1 – cesium2 – ammonium3 – potassium4 – sodium5 – magnesium6 – lithium7 – strontium8 – barium9 – calcium

Page 12: CAPILLARY ELECTROPHORESIS SYSTEMS CAPEL CAPILLARY ELECTROPHORESIS SYSTEMS CAPEL CERTIFICATION Simultaneous quantitative determination of several components

ANALYSIS OF THE ANION COMPOSITION OF THEANALYSIS OF THE ANION COMPOSITION OF THEPORTABLE, NATURAL AND WASTE WATERPORTABLE, NATURAL AND WASTE WATER

Buffer 5 mmol chromate, 20 mmol DEA, 1.65 mmol CTABSample calibration solution, 5 mg/l of each anion (fluoride 2.5 mg/l)Capillary l/L 50/ 60 cm, id 75 µmInjection 300 mbar*sVoltage 17 kVDetection 254 nm, indirect

1 chloride2 nitrite3 sulfate4 nitrate5 fluoride6 phosphate* bromide hollow** hydrocarbonate

Page 13: CAPILLARY ELECTROPHORESIS SYSTEMS CAPEL CAPILLARY ELECTROPHORESIS SYSTEMS CAPEL CERTIFICATION Simultaneous quantitative determination of several components

ANALYSIS OF PESTICIDES OF ANALYSIS OF PESTICIDES OF SYMMETRIC TRIAZINE GROUPSYMMETRIC TRIAZINE GROUP

Buffer 10 mmol sodium borate, 32 mmol SDSSample test solution, 2.5 mg/l of each compoundCapillary l/L 60/70 cm, id 75 µmInjection 900 mbar*sVoltage +20 kVDetection 229 nm

1 – simazine2 – atrazine3 – propazine4 – prometryne

Page 14: CAPILLARY ELECTROPHORESIS SYSTEMS CAPEL CAPILLARY ELECTROPHORESIS SYSTEMS CAPEL CERTIFICATION Simultaneous quantitative determination of several components

ANALYSIS OF SYNTHETIC ANALYSIS OF SYNTHETIC DYESDYES

Buffer 5 mmol phosphate, 5 mmol hydrocarbonate, pH 10.5Sample standard mixture of dyesCapillary l/L 50/60 cm, id 75 µmInjection 600 mbar*sVoltage +20 kVDetection 254 nm

1 – Rhodamine B (C.I. 45170) 2 – Patent Blue V (E131, C.I. 42051) 3 – Orange I (C.I. 14600) 4 – Acid Green S (E142, C.I. 44090) 5 – Acid Violet 5BN (C.I. 42650) 6 – Quinoline Yellow (E104, C.I. 47005) 7 – Sunset Yellow FCF (E110, C.I. 15985) 8 – Tartrazine (E102, C.I. 19140) 9 – Azorubine (E122, C.I. 14720)10 – Amaranth (E123, C.I. 16185)11 – Chrysoine (C.I. 14270)12 – Brilliant black PN (E151, C.I. 28440)13 – Indigotin (E132, C.I. 73015)14 – Brilliant Blue FCF (E133, C.I. 42090)

Page 15: CAPILLARY ELECTROPHORESIS SYSTEMS CAPEL CAPILLARY ELECTROPHORESIS SYSTEMS CAPEL CERTIFICATION Simultaneous quantitative determination of several components

ANALYSIS OF BENZOIC ACID ANALYSIS OF BENZOIC ACID DERIVATIVESDERIVATIVES

5 6 7 8 9 10 min

9.86 mAU

A

3-m

eth

ox

yb

enz.

2-m

eth

ylb

enzo

at

ben

zoa

te

ph

tali

c a

cid

Buffer 25 mM borate pH 9.18Capillary 26 / 35 cm, 50µm IDInjection 150 mbar x secVoltage 25 kV

Page 16: CAPILLARY ELECTROPHORESIS SYSTEMS CAPEL CAPILLARY ELECTROPHORESIS SYSTEMS CAPEL CERTIFICATION Simultaneous quantitative determination of several components

APPLICATIONSAPPLICATIONS

Determination of inorganic anions in water samples

Determination of inorganic cations in water samples

Determination of phenoxycarboxylic acid herbicides in water

Determination of caffeine and preservatives in beverages

Page 17: CAPILLARY ELECTROPHORESIS SYSTEMS CAPEL CAPILLARY ELECTROPHORESIS SYSTEMS CAPEL CERTIFICATION Simultaneous quantitative determination of several components

SPECIFICATIONSPECIFICATION

Capel-103 Capel-104 Capel-105

DetectorLine-source lamp, 254 nm

Light source - deuterium lamp190 – 380 nm

Operating modeManual

Fully automated,programmable

Capillary coolingAir-forced with ambient t°CIn ver.(T) – thermostatic liquid cooling with pre-set t°C

Liquid cooling with thermostabilisation, from -10 up to +30°C with respect to ambient

Sampler Manually operated for 4 vials

Autosampler, 10 inlet, 10 outlet vials

Page 18: CAPILLARY ELECTROPHORESIS SYSTEMS CAPEL CAPILLARY ELECTROPHORESIS SYSTEMS CAPEL CERTIFICATION Simultaneous quantitative determination of several components

CONTACTSCONTACTS

LUMEX LTD.LUMEX LTD.

19, Moskovskiy pr., St. Petersburg, 190005 RussiaPhone: +7 (812) 718-5390, +7 (812) 718-5391Fax: +7 (812) 316-6538E-mail: [email protected], [email protected]; http://www.lumex.ru

LUMEX INTERNATIONALLUMEX INTERNATIONAL

4736 Lee Hwy, suite 203, Arlington VA 22207, USAPhone/Fax: +1 (703) 243-7103;E-mail: [email protected]; http://www.lumexint.com

OhioLumex Co.OhioLumex Co.

9263, Ravenna Rd., Unit A3 Twinsburg, OH 44087 USAPhone: +1 (888) 876-2611; +1 (330) 405-0837Fax: +1 (330) 405-0847E-mail: [email protected], [email protected]; http://www.ohiolumex.com