Page 1: Cardio Vascular Monitoring, Anesthesia

Cardiovascular Monitoring

Presenter: Dr. Rashmit ShresthaModerator : Dr. Dipesh Man Singh

Page 2: Cardio Vascular Monitoring, Anesthesia

Introduction Although electronic devices constitute crucially important, the physician’s sense offer an integrated, panoramic view of the patient’s conditions

Inspection, Palpation and Auscultation are the cornerstones of the physical examination, they are also fundamental to perioperative CV monitor

Page 3: Cardio Vascular Monitoring, Anesthesia

STETHOSCOPEIt provides simple and reliable means of continuous monitoring of heart and breath sound.

Esophageal stethoscope facilitates temperature, clear breath and heart sound.

Page 4: Cardio Vascular Monitoring, Anesthesia
Page 5: Cardio Vascular Monitoring, Anesthesia

Heart Rate (HR) Monitoring

• The ECG is the most common method used in the OR.

• Accurate detection of the R wave and measurement of R-R wave interval serve as the basis from which digitally displayed values are derived and periodically updated.

Page 6: Cardio Vascular Monitoring, Anesthesia

Pulse Rate (PR) MonitoringHR from ECG tracePR from pulse oximeter plethysmograph or arterial blood pressure monitor.

Pulse Deficit = PR < HRSeen in Atrial Fibrillation, electromechanical dissociation or pulseless electrical activity ( e.g. cardiac tamponade, extreme hypovolemia).

Page 7: Cardio Vascular Monitoring, Anesthesia

Arterial Blood Pressure Monitoring

• A. Indirect Cuff Devices

• B. Direct Arterial Cannulation

Page 8: Cardio Vascular Monitoring, Anesthesia

Indirect measurement of Arterial BP

• Sphygmomanometer, first described by Riva Rocci in 1896.

Page 9: Cardio Vascular Monitoring, Anesthesia

• Arm encircling inflatable elastic cuff

• Rubber bulb to inflate the cuff pressure

• Radial artery palpated as pressure increased in cuff

• Mercury manometer.• Identifying ONLY systolic

blood pressure !

Page 10: Cardio Vascular Monitoring, Anesthesia

• Detecting both systolic and diastolic pressure became possible with the description of the auscultatory method of Blood Pressure measurement by Korotkoff in 1905.

Page 11: Cardio Vascular Monitoring, Anesthesia

Korotkoff sounds• Complex series of audible frequencies produced

by turbulent flow beyond the partially occluding cuff.

• Phase I : sound heard – systolic pressure• Phase II & III : sound character changes• Phase IV: becomes muffled• Phase V : absent • Diastolic Blood pressure at Phase IV & V

Page 12: Cardio Vascular Monitoring, Anesthesia

A well fitted cuff bladder that extends to 40% of arm circumference and 80% of length of the upper arm

Page 13: Cardio Vascular Monitoring, Anesthesia

Automated Intermittent Techniques• Automated noninvasive blood

pressure(NIBP) devices are standard equipment in most critical care settings because they provide frequent, regular pressure measurement, free the operator to perform other vital clinical duties, provide audible alarms, and can transfer data to a computerized information system.

Page 14: Cardio Vascular Monitoring, Anesthesia

Automated NIBP• Based on oscillometry

(Marey,1876) • Variation in cuff pressure

resulting from arterial pulsations during cuff deflation sensed by monitor

• Pressure at which peak amplitude of arterial pulsations occur, corresponds closely to direct measured MAP

• SBP and DBP are derived from proprietary formulas

• SBP and DBP are less reliable than MAP

Page 15: Cardio Vascular Monitoring, Anesthesia

Complications of NIBP Measurement• Pain• Petechiae and ecchymoses• Limb edema• Venous stasis and thrombophlebitis• Peripheral neuropathy• Compartment syndrome

Page 16: Cardio Vascular Monitoring, Anesthesia
Page 17: Cardio Vascular Monitoring, Anesthesia

Direct Measurement of Arterial BP• Indication for Arterial Cannulation– Continuous, real-time BP monitoring– Planned pharmacological or mechanical

cardiovascular manipulation– Repeated blood sampling– Failure or indirect arterial BP measurement – Supplementary diagnostic information from the

arterial waveform

Page 18: Cardio Vascular Monitoring, Anesthesia

Percutaneous Radial Artery Cannulation

• Radial artery(RA) is the most common site.

• Before attempting RA cannulation, assessment of the adequacy of collateral flow to the hand is performed by modified Allen test.

Page 19: Cardio Vascular Monitoring, Anesthesia

Allen’s test

Page 20: Cardio Vascular Monitoring, Anesthesia

Arterial line insertion

Page 21: Cardio Vascular Monitoring, Anesthesia

Alternative Arterial Pressure Monitoring Sites

• Ulnar artery• Brachial artery• Axillary arteryFemoral arteryLess commonly used:Dorsalis pedisPosterior tibialSuperficial temporal arteries

Page 22: Cardio Vascular Monitoring, Anesthesia
Page 23: Cardio Vascular Monitoring, Anesthesia
Page 24: Cardio Vascular Monitoring, Anesthesia
Page 25: Cardio Vascular Monitoring, Anesthesia
Page 26: Cardio Vascular Monitoring, Anesthesia
Page 27: Cardio Vascular Monitoring, Anesthesia
Page 28: Cardio Vascular Monitoring, Anesthesia

Complications of Direct Arterial Pressure Monitoring

• Distal Ischemia, pseudoaneurysm, arteriovenous fistula

• Hemorrhage• Arterial embolization• Infection• Peripheral neuropathy• Misinterpretation of data• Misuse of equipment.

Page 29: Cardio Vascular Monitoring, Anesthesia

Central Venous Pressure Monitoring• Indications for Central Venous CannulationCVP monitoringPulmonary artery catherterization and monitoringTransvenous cardiac pacingTemoporary hemodialysisDrug adminstration : Concentrated vasoactive drugs, hyperalimentation, chemotherapy etcRapid infusions of fluids Aspiration of air emboliInadequate peripheral intravenous accessSampling site for repeated blood testing

Page 30: Cardio Vascular Monitoring, Anesthesia

Central Venous Catheterization (Rt. IJV)

Page 31: Cardio Vascular Monitoring, Anesthesia
Page 32: Cardio Vascular Monitoring, Anesthesia
Page 33: Cardio Vascular Monitoring, Anesthesia

Atrial Fibrillation, absence of a wave, prominent c wave, preserved x and y

decent

Page 34: Cardio Vascular Monitoring, Anesthesia
Page 35: Cardio Vascular Monitoring, Anesthesia
Page 36: Cardio Vascular Monitoring, Anesthesia

Complications of Central Venous Pressure Monitorng

• Mechanical : – Vascular injury : arterial, venous, cardiac tamponade• Respiratory compromise :- Airway compression from hematoma, Pneumothorax• Nerve injury• Arrhythmias • Thromboembolism • Infections • Misinterpretation of data• Misuse of equipment

Page 37: Cardio Vascular Monitoring, Anesthesia

THANK YOU !

Page 38: Cardio Vascular Monitoring, Anesthesia

References1. Miller’s Anesthesia, 8th Edition, Cardiovascular monitoring,

page 1345-2. https://en.wikipedia.org/wiki/Korotkoff_sounds3. https://www.youtube.com/watch?v=8xpKr1t7YQE4. Morgan and Mikhail’s Clinical Anesthesia. 5th Editions.