care air centre - iwma tnpcb.pdf · vcm fluorine flow temp parameters monitored at cac ambient...

34
TAMIL NADU POLLUTION CONTROL BOARD CARE AIR CENTRE CENTRE FOR ASSESSING REAL TIME AIR (QUALITY) INFORMATION REPORTS

Upload: others

Post on 14-Aug-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CARE AIR CENTRE - IWMA TNPCB.pdf · VCM Fluorine Flow Temp Parameters Monitored at CAC Ambient Parameters PM 10 PM 2.5 SO 2 ... Training Understanding ... Chennai-32 Ph: 044 22353157

TAMIL NADU POLLUTION CONTROL BOARD

CARE AIR CENTRE

CENTRE FOR ASSESSING REAL TIME AIR (QUALITY) INFORMATION REPORTS

Page 2: CARE AIR CENTRE - IWMA TNPCB.pdf · VCM Fluorine Flow Temp Parameters Monitored at CAC Ambient Parameters PM 10 PM 2.5 SO 2 ... Training Understanding ... Chennai-32 Ph: 044 22353157

Vision of CARE AIR CENTRE

• To monitor all the industrial emissions in TamilNadu on real

time basis to analyse the trend of emissions into the

Atmosphere.

• Apart from Emission monitoring, Ambient Air monitoring

around the Industrial premises and Effluent parameters are

monitored at the Centre

Page 3: CARE AIR CENTRE - IWMA TNPCB.pdf · VCM Fluorine Flow Temp Parameters Monitored at CAC Ambient Parameters PM 10 PM 2.5 SO 2 ... Training Understanding ... Chennai-32 Ph: 044 22353157

Online Monitoring Client-Server Environment at

TNPCB

Page 4: CARE AIR CENTRE - IWMA TNPCB.pdf · VCM Fluorine Flow Temp Parameters Monitored at CAC Ambient Parameters PM 10 PM 2.5 SO 2 ... Training Understanding ... Chennai-32 Ph: 044 22353157

In August 2015 the TNPCB has introduced an new client-server

environment.

In this platform the central sever is unique and the client side is an open

module.

To facilitate more connectivity & easy access to industry and regulator.

Industry-A client side

Industry-B client side

Industry-C client side

Central Server (TNPCB)

Page 5: CARE AIR CENTRE - IWMA TNPCB.pdf · VCM Fluorine Flow Temp Parameters Monitored at CAC Ambient Parameters PM 10 PM 2.5 SO 2 ... Training Understanding ... Chennai-32 Ph: 044 22353157

New Central Server Login Page:

Central Server (TNPCB)

Page 6: CARE AIR CENTRE - IWMA TNPCB.pdf · VCM Fluorine Flow Temp Parameters Monitored at CAC Ambient Parameters PM 10 PM 2.5 SO 2 ... Training Understanding ... Chennai-32 Ph: 044 22353157

Site Status

Page 7: CARE AIR CENTRE - IWMA TNPCB.pdf · VCM Fluorine Flow Temp Parameters Monitored at CAC Ambient Parameters PM 10 PM 2.5 SO 2 ... Training Understanding ... Chennai-32 Ph: 044 22353157

Data Analysis at CAC TNPCB

Page 8: CARE AIR CENTRE - IWMA TNPCB.pdf · VCM Fluorine Flow Temp Parameters Monitored at CAC Ambient Parameters PM 10 PM 2.5 SO 2 ... Training Understanding ... Chennai-32 Ph: 044 22353157

Automated Alerts sent to the Industry & Regulator

Page 9: CARE AIR CENTRE - IWMA TNPCB.pdf · VCM Fluorine Flow Temp Parameters Monitored at CAC Ambient Parameters PM 10 PM 2.5 SO 2 ... Training Understanding ... Chennai-32 Ph: 044 22353157

Emission Parameters

PM

SO2

NOx

CO

CO2

THC

VOC

NH3

HF

Cl2

HCl

Mercapton

VCM

Fluorine

Flow

Temp

Parameters Monitored at CAC

Ambient Parameters

PM10

PM2.5

SO2

NO

NO2

NOx

CO

C6H6

Cl2 HCl

VOC

NH3

CH4

HCNM

Fluorine

HCT

VCM

O3

Bromine

Hydrogen

RH

Temp

Wind Direction

Wind speed

Effluent Parameters

pH

TDS

Flow

Temperature

Page 10: CARE AIR CENTRE - IWMA TNPCB.pdf · VCM Fluorine Flow Temp Parameters Monitored at CAC Ambient Parameters PM 10 PM 2.5 SO 2 ... Training Understanding ... Chennai-32 Ph: 044 22353157

Sector Wise Monitoring (Cement plants)

Page 11: CARE AIR CENTRE - IWMA TNPCB.pdf · VCM Fluorine Flow Temp Parameters Monitored at CAC Ambient Parameters PM 10 PM 2.5 SO 2 ... Training Understanding ... Chennai-32 Ph: 044 22353157

Sector Wise Monitoring (Power plants)

Page 12: CARE AIR CENTRE - IWMA TNPCB.pdf · VCM Fluorine Flow Temp Parameters Monitored at CAC Ambient Parameters PM 10 PM 2.5 SO 2 ... Training Understanding ... Chennai-32 Ph: 044 22353157

Online Remote Calibration performed at

Care Air Centre(TNPCB)

Page 13: CARE AIR CENTRE - IWMA TNPCB.pdf · VCM Fluorine Flow Temp Parameters Monitored at CAC Ambient Parameters PM 10 PM 2.5 SO 2 ... Training Understanding ... Chennai-32 Ph: 044 22353157

Calibration Details

Page 14: CARE AIR CENTRE - IWMA TNPCB.pdf · VCM Fluorine Flow Temp Parameters Monitored at CAC Ambient Parameters PM 10 PM 2.5 SO 2 ... Training Understanding ... Chennai-32 Ph: 044 22353157

Report on Calibration

Page 15: CARE AIR CENTRE - IWMA TNPCB.pdf · VCM Fluorine Flow Temp Parameters Monitored at CAC Ambient Parameters PM 10 PM 2.5 SO 2 ... Training Understanding ... Chennai-32 Ph: 044 22353157

Data- Exceedance

Page 16: CARE AIR CENTRE - IWMA TNPCB.pdf · VCM Fluorine Flow Temp Parameters Monitored at CAC Ambient Parameters PM 10 PM 2.5 SO 2 ... Training Understanding ... Chennai-32 Ph: 044 22353157

Daily profile Report of different Analyser model and

make in a Industry Area.

Page 17: CARE AIR CENTRE - IWMA TNPCB.pdf · VCM Fluorine Flow Temp Parameters Monitored at CAC Ambient Parameters PM 10 PM 2.5 SO 2 ... Training Understanding ... Chennai-32 Ph: 044 22353157

Hourly Profile of PM10 in Industry Area for Period of

1year(2013-2014)

Page 18: CARE AIR CENTRE - IWMA TNPCB.pdf · VCM Fluorine Flow Temp Parameters Monitored at CAC Ambient Parameters PM 10 PM 2.5 SO 2 ... Training Understanding ... Chennai-32 Ph: 044 22353157
Page 19: CARE AIR CENTRE - IWMA TNPCB.pdf · VCM Fluorine Flow Temp Parameters Monitored at CAC Ambient Parameters PM 10 PM 2.5 SO 2 ... Training Understanding ... Chennai-32 Ph: 044 22353157

Vision of Water Quality Watch

1. To build a Real Time Monitoring System for Water Pollution

Monitoring in terms of quantitative measurements and

qualitative measurements.

2. To monitor operations of Effluent Treatment plants,

performance evaluation of waste water recovery system, and

reject management system.

3. To ensure Zero Liquid Discharge System (ZLDS) of IETPs

and CETPs.

4. To monitor member unit as part of CETPs.

5. Monitoring of water quality of river and water bodies.

Page 20: CARE AIR CENTRE - IWMA TNPCB.pdf · VCM Fluorine Flow Temp Parameters Monitored at CAC Ambient Parameters PM 10 PM 2.5 SO 2 ... Training Understanding ... Chennai-32 Ph: 044 22353157

Water Quality Monitoring & Parameters

1. Effluent Discharge from Industries

- BOD, COD, TSS, pH, Temp, Flow

2. ZLDS Units

- Water, Energy, Steam, DO, pH, TDS, Pressure, Tank Level

3. Rivers & Water Bodies

- Temperature, TDS, DO, pH, Depth

Page 21: CARE AIR CENTRE - IWMA TNPCB.pdf · VCM Fluorine Flow Temp Parameters Monitored at CAC Ambient Parameters PM 10 PM 2.5 SO 2 ... Training Understanding ... Chennai-32 Ph: 044 22353157

In August 2015 the TNPCB has introduced an new client-

server environment for WQW

WQW is exclusively for effluent monitoring , the data are

in cumulative basis.

Industry-A client side

Industry-B client side

Industry-C client side

Central

Server(TNPCB)

Page 22: CARE AIR CENTRE - IWMA TNPCB.pdf · VCM Fluorine Flow Temp Parameters Monitored at CAC Ambient Parameters PM 10 PM 2.5 SO 2 ... Training Understanding ... Chennai-32 Ph: 044 22353157

Water Quality Trend Graph – TSS in mg/Litre

Page 23: CARE AIR CENTRE - IWMA TNPCB.pdf · VCM Fluorine Flow Temp Parameters Monitored at CAC Ambient Parameters PM 10 PM 2.5 SO 2 ... Training Understanding ... Chennai-32 Ph: 044 22353157

ZLDS Performance – RO Recovery

Page 24: CARE AIR CENTRE - IWMA TNPCB.pdf · VCM Fluorine Flow Temp Parameters Monitored at CAC Ambient Parameters PM 10 PM 2.5 SO 2 ... Training Understanding ... Chennai-32 Ph: 044 22353157

ZLDS Performance – Energy Audit

Page 25: CARE AIR CENTRE - IWMA TNPCB.pdf · VCM Fluorine Flow Temp Parameters Monitored at CAC Ambient Parameters PM 10 PM 2.5 SO 2 ... Training Understanding ... Chennai-32 Ph: 044 22353157

ZLDS Performance and

Industrial and makeup water

Page 26: CARE AIR CENTRE - IWMA TNPCB.pdf · VCM Fluorine Flow Temp Parameters Monitored at CAC Ambient Parameters PM 10 PM 2.5 SO 2 ... Training Understanding ... Chennai-32 Ph: 044 22353157

ZLDS Performance – Water Balance

Page 27: CARE AIR CENTRE - IWMA TNPCB.pdf · VCM Fluorine Flow Temp Parameters Monitored at CAC Ambient Parameters PM 10 PM 2.5 SO 2 ... Training Understanding ... Chennai-32 Ph: 044 22353157

ZLDS Performance – Full Schematic

Page 28: CARE AIR CENTRE - IWMA TNPCB.pdf · VCM Fluorine Flow Temp Parameters Monitored at CAC Ambient Parameters PM 10 PM 2.5 SO 2 ... Training Understanding ... Chennai-32 Ph: 044 22353157

Water Exchange Verification between CETP & Member Units

Page 29: CARE AIR CENTRE - IWMA TNPCB.pdf · VCM Fluorine Flow Temp Parameters Monitored at CAC Ambient Parameters PM 10 PM 2.5 SO 2 ... Training Understanding ... Chennai-32 Ph: 044 22353157

Quantitative Monitoring

Electro Magnetic Flow Meter (EMFM)

Instantaneous Value

Cumulative Value

Page 30: CARE AIR CENTRE - IWMA TNPCB.pdf · VCM Fluorine Flow Temp Parameters Monitored at CAC Ambient Parameters PM 10 PM 2.5 SO 2 ... Training Understanding ... Chennai-32 Ph: 044 22353157

Digital Communication Technology

Both

Flow Rate & Total Flow

can be read from

Flow Meter to Computer

(without conversion)

Page 31: CARE AIR CENTRE - IWMA TNPCB.pdf · VCM Fluorine Flow Temp Parameters Monitored at CAC Ambient Parameters PM 10 PM 2.5 SO 2 ... Training Understanding ... Chennai-32 Ph: 044 22353157

Issues in online Monitoring

No Quality analyser

Connecting thru in between logic

Manipulating data

Sensors are sold as analyser in Indian market for cheap price to convince the regulator.

No trained manpower

Limited knowledge CEMS management

Lack of resources to understand the same

Avoidance of CEMS regime

Page 32: CARE AIR CENTRE - IWMA TNPCB.pdf · VCM Fluorine Flow Temp Parameters Monitored at CAC Ambient Parameters PM 10 PM 2.5 SO 2 ... Training Understanding ... Chennai-32 Ph: 044 22353157

Basic Requirement of Today in Industries perspective

Cheap analyser

Easy un-interrupted data transfer system

Training

To conduct Calibration of the analyser with required frequency

To maintain necessary logs

Conducting Third party trial and Audits

Manpower availability

Page 33: CARE AIR CENTRE - IWMA TNPCB.pdf · VCM Fluorine Flow Temp Parameters Monitored at CAC Ambient Parameters PM 10 PM 2.5 SO 2 ... Training Understanding ... Chennai-32 Ph: 044 22353157

Today requirement in Regulators perspective

Training

Understanding CEMS and data management

Calibration and data Validation

Establishment of Online monitoring centers

Generation of Reports

Preparation of Report for Pollution Mitigation and Management

Web publishing and Management etc

Technical manpower

Page 34: CARE AIR CENTRE - IWMA TNPCB.pdf · VCM Fluorine Flow Temp Parameters Monitored at CAC Ambient Parameters PM 10 PM 2.5 SO 2 ... Training Understanding ... Chennai-32 Ph: 044 22353157

Thank You

R.Dhanasekaran,

Chief Scientific Officer,

Tamilnadu Pollution Control Board

76, Mount Salai, Guindy,

Chennai-32

Ph: 044 22353157

Email: [email protected],

[email protected],

[email protected]