case afs pro 300, 600, 700 & intelliview ii, iii, iv (case ... · m04 54vt-pro-pt01-inst manual...

14
Case AFS PRO 300, 600, 700 & INTELLIVIEW II, III, IV (Case & NH ISObus Ready) Display Kit Installation Manual 54VT-PRO-PT01

Upload: others

Post on 20-Mar-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Case AFS PRO 300, 600, 700 & INTELLIVIEW II, III, IV (Case ... · M04 54VT-PRO-PT01-INST MANUAL UC5 DISPLAY KIT CASE AFS PRO 300, 600, 700 & INTELLIVIEW II, III, IV (CASE & NH ISOBUS

Case AFS PRO 300, 600, 700 & INTELLIVIEW II, III, IV (Case & NH ISObus Ready) Display Kit

Installation Manual 54VT-PRO-PT01

Page 2: Case AFS PRO 300, 600, 700 & INTELLIVIEW II, III, IV (Case ... · M04 54VT-PRO-PT01-INST MANUAL UC5 DISPLAY KIT CASE AFS PRO 300, 600, 700 & INTELLIVIEW II, III, IV (CASE & NH ISOBUS

Printed in Canada Copyright 2010 by NORAC Systems International Inc. Reorder P/N: 54VT-PRO-PT01-INST Rev B (Case AFS PRO 300, 600, 700 & INTELLIVIEW II,

III, IV (Case & NH ISObus Ready) Display Kit)

NOTICE: NORAC Systems International Inc. reserves the right to improve products and their specifications without notice and without the requirement to update products sold previously. Every effort has been made to ensure the accuracy of the information contained in this manual. The technical information in this manual was reviewed at the time of approval for publication.

Page 3: Case AFS PRO 300, 600, 700 & INTELLIVIEW II, III, IV (Case ... · M04 54VT-PRO-PT01-INST MANUAL UC5 DISPLAY KIT CASE AFS PRO 300, 600, 700 & INTELLIVIEW II, III, IV (CASE & NH ISOBUS

1

Contents

1  INTRODUCTION ...................................................................................................... 2 

1.1  VT Software Version..........................................................................................................................................................2 

1.2  List of Parts ..........................................................................................................................................................................2 

1.3  Alternate Cabling ................................................................................................................................................................2 

2  TECHNICAL SPECIFICATIONS ............................................................................. 3 

3  INSTALLATION ........................................................................................................ 4 

3.1  CANbus Interface Installation ..........................................................................................................................................4 

3.2  Switch Box Installation ......................................................................................................................................................5 

4  CABLE DRAWINGS .................................................................................................. 6 

4.1  ITEM C25: 44602-01 – Switch Remote Hand Control .............................................................................................6 

4.2  ITEM C26: 43240-26 – Cable UC5 Switch Box ..........................................................................................................7 

4.3  ITEM C30: 43250-06 – Cable UC5 Battery Pigtail Fused - 5A ................................................................................8 

4.4  ITEM C40: 43260-08 – Cable UC5 Interface CANBus 4 Pin DT ...........................................................................9 

4.5  ITEM C41: 43220-03 - Cable UC5 Network 14 AWG - 3M ................................................................................. 10 

APPENDIX A: ALTERNATE CONFIGURATION ..................................................... 11 

Page 4: Case AFS PRO 300, 600, 700 & INTELLIVIEW II, III, IV (Case ... · M04 54VT-PRO-PT01-INST MANUAL UC5 DISPLAY KIT CASE AFS PRO 300, 600, 700 & INTELLIVIEW II, III, IV (CASE & NH ISOBUS

2

1 Introduction

The Case AFS Pro 300, 600, 700 & INTELLIVIEW II, III, IV Display Kit Manual is intended to be used in conjunction with the UC5 Spray Height Control Installation Manual. This manual provides instructions to interface the UC5 Control Module to the Case AFS Pro 300, 600, 700 or INTELLIVIEW II, III, IV Display. For installation of the rest of the UC5 Spray Height Control System please refer to the sprayer specific manual provided with the kit.

1.1 VT Software Version

Before connecting the UC5 to the Case AFS Pro 300, 600 or 700, ensure that the latest VT software is installed. The VT software must be Version 25 or newer.

1.2 List of Parts

Item Part Number Name Quantity

C25 44602-01 BOX SWITCH UC4 REMOTE HAND CONTROL VER.1 RMR 1

C26 43240-26 CABLE UC5 INTERFACE SWITCH BOX 1

C30 43250-06 CABLE UC5 BATTERY PIGTAIL FUSED - 5A 1

C40 43260-08 CABLE UC5 INTERFACE CAN BUS 4 PIN DT 1

C41 43220-03 CABLE UC5 NETWORK 14 AWG 3M 1

E12 43764 UC5 NETWORK COUPLER 2-WAY 1

M01 UC5-BC-MANUAL-VT MANUAL UC5 OPERATORS - ECHO/VT 1

M04 54VT-PRO-PT01-INSTMANUAL UC5 DISPLAY KIT CASE AFS PRO 300, 600, 700 & INTELLIVIEW II, III, IV (CASE & NH ISOBUS READY)

1

1.3 Alternate Cabling

Some tractors may require a different C40 cable depending on the connectors used for the ISOBUS. Please refer to the table below for ordering alternate cabling from NORAC.

Item Part Number Name Quantity

C40 43260-09 CABLE UC5 INTERFACE CAN BUS 6 PIN METRI-PACK 150 1

Page 5: Case AFS PRO 300, 600, 700 & INTELLIVIEW II, III, IV (Case ... · M04 54VT-PRO-PT01-INST MANUAL UC5 DISPLAY KIT CASE AFS PRO 300, 600, 700 & INTELLIVIEW II, III, IV (CASE & NH ISOBUS

3

2 Technical Specifications

CAN ICES-3(A)/NMB-3(A) This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at their own expense.

This Class A digital apparatus complies with Canadian ICES-003.

Pursuant to EMC Directive – Article 9, this product is not intended for residential use.

Table 1: System Specifications

Supply Voltage (rated) 12VDC Supply Current (rated) 5A Hydraulic Pressure (maximum) 3300 psi Baud Rate 250 kbps Clock Frequency (maximum) 96 MHz Solenoid Valve PWM Frequency 300 Hz Ultrasonic Sensor Transmit Frequency 50 kHz Operating Temperature Range 0°C to 80°C

Page 6: Case AFS PRO 300, 600, 700 & INTELLIVIEW II, III, IV (Case ... · M04 54VT-PRO-PT01-INST MANUAL UC5 DISPLAY KIT CASE AFS PRO 300, 600, 700 & INTELLIVIEW II, III, IV (CASE & NH ISOBUS

4

3 Installation

3.1 CANbus Interface Installation

1. Securely mount the control module (E01) at the rear of the cab.

2. Tee the CANbus interface cable (C40) in to the CANbus at the terminator behind the ISOBUS connector. The ISOBUS connector is located on the rear of the tractor above the drawbar. Connect the 6 pin Deutsch plug on cable C40 to the end of the control module with only one Deutsch connector. See Section 1.3 for alternate cabling, if required.

3. Connect cable C30 to the CANbus connector. Connect the other end of C30 to an appropriate power supply.

4. Connect cable C41 to the CANbus connector and route the cable to the hitch of the tractor. Connect the two-way coupler (E12) to the end of cable C41.

5. Connect cable C01 to the coupler (E12) and route towards the rear of the sprayer. The two-way coupler (E12) will provide the hitch disconnect.

Figure 1: CANbus Interface Installation

Page 7: Case AFS PRO 300, 600, 700 & INTELLIVIEW II, III, IV (Case ... · M04 54VT-PRO-PT01-INST MANUAL UC5 DISPLAY KIT CASE AFS PRO 300, 600, 700 & INTELLIVIEW II, III, IV (CASE & NH ISOBUS

5

3.2 Switch Box Installation

1. Disconnect cable C20 from the Thru 2 connector on the Input Module (E03). Remove the wedge from the face of the 12-pin Deutsch plug.

2. Insert the Roll CW pin from C26 into position 3 of the 12-pin plug on C20. Insert the Roll CCW pin from C26 into position 4 of the 12-pin plug on C20. Insert the wedge back into the plug. Connect C20 to the Thru 2 connector on the Input Module.

3. Connect the 12-pin Deutsch plug on C26 to the OEM 3 connector on the input module. Route the other end of the cable to the hitch of the sprayer.

4. Attach the switch box (C25) inside the cab and connect it to cable C26. An extra label is provided with the switch box if you prefer to remove the switches from the housing and mount them in the existing sprayer switch panel.

* Some sprayer types may not use all the switch functions.

* Refer to “Appendix A” for sprayers with European style slant control.

Figure 2: Switch Box Installation

Page 8: Case AFS PRO 300, 600, 700 & INTELLIVIEW II, III, IV (Case ... · M04 54VT-PRO-PT01-INST MANUAL UC5 DISPLAY KIT CASE AFS PRO 300, 600, 700 & INTELLIVIEW II, III, IV (CASE & NH ISOBUS

6

4 Cable Drawings

4.1 ITEM C25: 44602-01 – Switch Remote Hand Control

Page 9: Case AFS PRO 300, 600, 700 & INTELLIVIEW II, III, IV (Case ... · M04 54VT-PRO-PT01-INST MANUAL UC5 DISPLAY KIT CASE AFS PRO 300, 600, 700 & INTELLIVIEW II, III, IV (CASE & NH ISOBUS

7

4.2 ITEM C26: 43240-26 – Cable UC5 Switch Box

Page 10: Case AFS PRO 300, 600, 700 & INTELLIVIEW II, III, IV (Case ... · M04 54VT-PRO-PT01-INST MANUAL UC5 DISPLAY KIT CASE AFS PRO 300, 600, 700 & INTELLIVIEW II, III, IV (CASE & NH ISOBUS

8

4.3 ITEM C30: 43250-06 – Cable UC5 Battery Pigtail Fused - 5A

Page 11: Case AFS PRO 300, 600, 700 & INTELLIVIEW II, III, IV (Case ... · M04 54VT-PRO-PT01-INST MANUAL UC5 DISPLAY KIT CASE AFS PRO 300, 600, 700 & INTELLIVIEW II, III, IV (CASE & NH ISOBUS

9

4.4 ITEM C40: 43260-08 – Cable UC5 Interface CANBus 4 Pin DT

Page 12: Case AFS PRO 300, 600, 700 & INTELLIVIEW II, III, IV (Case ... · M04 54VT-PRO-PT01-INST MANUAL UC5 DISPLAY KIT CASE AFS PRO 300, 600, 700 & INTELLIVIEW II, III, IV (CASE & NH ISOBUS

10

4.5 ITEM C41: 43220-03 - Cable UC5 Network 14 AWG - 3M

Page 13: Case AFS PRO 300, 600, 700 & INTELLIVIEW II, III, IV (Case ... · M04 54VT-PRO-PT01-INST MANUAL UC5 DISPLAY KIT CASE AFS PRO 300, 600, 700 & INTELLIVIEW II, III, IV (CASE & NH ISOBUS

11

Appendix A: Alternate Configuration

If the sprayer has European style slant control, reconfigure the switch box as shown below. This is only required for sprayer types which are driving the slant output from the Input Module. Reconfigure the pins on cable C26 as follows:

Connector Pin Location Connector Pin Location

Power White Grey End (C26) 1 Grey End (C26) 1

Ground Black Grey End (C26) 12 Grey End (C26) 12

Remote Auto Brown Grey End (C26) 11 Grey End (C26) 11

Remote Manual Blue Grey End (C26) 10 Grey Side (C20) 4

Main Up Purple Grey End (C26) 9 Grey End (C26) 9

Main Down Yellow Grey End (C26) 8 Grey End (C26) 8

Roll CW Red Grey Side (C20) 3 Grey End (C26) 6

Roll CCW Orange Grey Side (C20) 4 Grey End (C26) 10

European Style Slant ConfigurationWire Color

Function (Cable C26)

Normal Configuration

Page 14: Case AFS PRO 300, 600, 700 & INTELLIVIEW II, III, IV (Case ... · M04 54VT-PRO-PT01-INST MANUAL UC5 DISPLAY KIT CASE AFS PRO 300, 600, 700 & INTELLIVIEW II, III, IV (CASE & NH ISOBUS

Canada NORAC Systems International Inc.

Phone: (+1) 306 664 6711 Toll Free: 1 800 667 3921

Shipping Address: 3702 Kinnear Place

Saskatoon, SK S7P 0A6

United States NORAC, Inc.

Phone: (+1) 952 224 4142 Toll Free: 1 866 306 6722

Shipping Address: 6667 West Old Shakopee Road, Suite 111

Bloomington, MN 55438

Europe NORAC Europe

Phone: (+33) (0)4 26 47 04 42 Shipping Address:

Rue de l’hermitage 01090 GUEREINS

France

www.norac.ca