Aerogel Composite Improves U-Value of Barrel Vault Ceiling Floor to ceiling height conserved in museum CASE STUDY Location: Imperial War Museum, London Fabrication Partner: The Proctor Group Provide ceiling insulation for Barrel Vault area of Imperial War Museum in London. This area was overheating in the summer and very cold in the winter. Improve u-value to below 0.2W/m2K, while not reducing the floor to ceiling height. The Proctor Group installed 20 mm of its Spacetherm blanket insulation on the ceiling. Spacetherm is a composite of Spaceloft ® insulation and fibrous matting. It has a thermal conductivity of only 0.013W/mk, enabling high thermal performance in a thin, flexible blanket. Spacetherm achieved a u-value of 0.18W/m2K, which exceeded the specification. Spacetherm’s 20 mm thickness barely reduced the floor to ceiling height. CHALLENGES DETAILS SOLUTIONS BENEFITS Aspen Aerogels, Inc. 30 Forbes Road, Building B Northborough, MA 01532 USA Aspen Aerogels and Spaceloft are registered trademarks of Aspen Aerogels, Inc. © 2011 Aspen Aerogels, Inc. REV 1.0 Phone: Fax: E-Mail: Web: 508.691.1111 508.691.1200 [email protected] www.aerogel.com Spaceloft - High Performance Insulation for Building Envelopes

Upload: reflexy-nederland-bv

Post on 08-Mar-2016

218 views

Category:

Documents


2 download

DESCRIPTION

 

TRANSCRIPT

Page 1: Case study U-Value of barrel vault ceiling Reflexy Nederland

Aerogel Composite Improves U-Value of Barrel Vault Ceiling

Floor to ceiling height conserved in museum

C A S E S T U D Y

Location: Imperial War Museum, London Fabrication Partner: The Proctor Group

Provide ceiling insulation for Barrel Vault area of Imperial War Museum in London. This area was overheating in the summer and very cold in the winter.Improve u-value to below 0.2W/m2K, while not reducing the floor to ceiling height.

The Proctor Group installed 20 mm of its Spacetherm blanket insulation on the ceiling. Spacetherm is a composite of Spaceloft® insulation and fibrous matting. It has a thermal conductivity of only 0.013W/mk, enabling high thermal performance in a thin, flexible blanket.

Spacetherm achieved a u-value of 0.18W/m2K, which exceeded the specification.Spacetherm’s 20 mm thickness barely reduced the floor to ceiling height.

••

••

CHALLENGES

DETAILS

SOLUTIONS

BENEFITS

Aspen Aerogels, Inc.30 Forbes Road, Building BNorthborough, MA 01532USA

Aspen Aerogels and Spaceloft are registered trademarks of Aspen Aerogels, Inc.© 2011 Aspen Aerogels, Inc.

REV 1.0

Phone:Fax:E-Mail:Web:

[email protected]

Spaceloft - High Performance Insulation for Building Envelopes