Cat6 Shielded Channel Performance

Sterling VadenSuperior Modular Products

Page 2: Cat6 Shielded Channel Performance - IEEE-SAgrouper.ieee.org/groups/802/3/10GBT/public/sep03/vaden_1_0903.pdf · Microsoft PowerPoint - Vaden_091003_Shielded_Cat6.ppt Author: savaden

Cat6 Shielded Description

• Four connector, 100 meter channel• Shielded Cat6 compliant connectors.• Cat6 rated SSTP horizontal cable

(individually shielded pairs)• SSTP patch cords

Page 3: Cat6 Shielded Channel Performance - IEEE-SAgrouper.ieee.org/groups/802/3/10GBT/public/sep03/vaden_1_0903.pdf · Microsoft PowerPoint - Vaden_091003_Shielded_Cat6.ppt Author: savaden

Cat6 SSTP cable

• Foil shield over each pair

• No overall braid • Similar in size to Cat6

UTP cable

Page 4: Cat6 Shielded Channel Performance - IEEE-SAgrouper.ieee.org/groups/802/3/10GBT/public/sep03/vaden_1_0903.pdf · Microsoft PowerPoint - Vaden_091003_Shielded_Cat6.ppt Author: savaden

Channel TopologyTest

InterfaceNear End

a b c d e TestInterfaceFar End

solid stranded stranded solidsolid

C2C1 C3 C4

Length a = 7 m Length c = 76 m Length e = 7 m

Length b = 5 m Length d = 5 m

Page 5: Cat6 Shielded Channel Performance - IEEE-SAgrouper.ieee.org/groups/802/3/10GBT/public/sep03/vaden_1_0903.pdf · Microsoft PowerPoint - Vaden_091003_Shielded_Cat6.ppt Author: savaden

Cable arrangement for testing

• Six cables bundled together using tape every meter

• 90 meters of cable • No separation

between bundles on floor

Page 6: Cat6 Shielded Channel Performance - IEEE-SAgrouper.ieee.org/groups/802/3/10GBT/public/sep03/vaden_1_0903.pdf · Microsoft PowerPoint - Vaden_091003_Shielded_Cat6.ppt Author: savaden

Cables on rack for test• Two racks like this were

used, one at the near end and one at the far end.

• Patch cords left looped• Pyramid adapters used

with Cat6 test fixtures.• All unused pairs

common mode terminated.

Page 7: Cat6 Shielded Channel Performance - IEEE-SAgrouper.ieee.org/groups/802/3/10GBT/public/sep03/vaden_1_0903.pdf · Microsoft PowerPoint - Vaden_091003_Shielded_Cat6.ppt Author: savaden

Testing

• All pair combinations were measured for NEXT, FEXT, Insertion Loss, and Return Loss, Including all ANEXT and AFEXT combinations.

• Frequency range from 1 to 500 MHz• Only a sample of data will be shown• Full data sets available for analysis on CD.

Page 8: Cat6 Shielded Channel Performance - IEEE-SAgrouper.ieee.org/groups/802/3/10GBT/public/sep03/vaden_1_0903.pdf · Microsoft PowerPoint - Vaden_091003_Shielded_Cat6.ppt Author: savaden

Network analyzer NEXT noise floor

R e s id ual N E X T

-1 2 0

-1 1 0

-1 0 0

-9 0

-8 0

-7 0

-6 0

0 1 0 0 2 0 0 3 0 0 4 0 0 5 0 0 6 0 0

F , M H z

NE

XT,

dB

1 2 N E X T F w d1 3 N E X T F w d1 4 N E X T F w d2 3 N E X T F w d2 4 N E X T F w d3 4 N E X T F w d1 2 N E X T R e v1 3 N E X T R e v1 4 N E X T R e v2 3 N E X T R e v2 4 N E X T R e v3 4 N E X T R e v

Page 9: Cat6 Shielded Channel Performance - IEEE-SAgrouper.ieee.org/groups/802/3/10GBT/public/sep03/vaden_1_0903.pdf · Microsoft PowerPoint - Vaden_091003_Shielded_Cat6.ppt Author: savaden

Typical NEXT, IL, RL, ELFEXTReturn Loss

-70

-60

-50

-40

-30

-20

-10

00 100 200 300 400 500 600

S11 dBS22 dBS33 dBS44 dBS55 dBS66 dBS77 dBS88 dBRL CH

Insertion Loss

-60

-50

-40

-30

-20

-10

00 100 200 300 400 500 600

S15 dBS26 dBS37 dBS48 dBIL Cat6 CH

PS NEXT

-100

-90

-80

-70

-60

-50

-40

-30

-20

-10

00 100 200 300 400 500 600

Pr1 PSNEXTPr2 PSNEXTPr3 PSNEXTPr4 PSNEXTPS NEXT CH

PS ELFEXT

-80

-70

-60

-50

-40

-30

-20

-10

00 100 200 300 400 500 600

Pr1 PSELFEXTPr2 PSELFEXTPr3 PSELFEXTPr4 PSELFEXTPS ELFEXT CH

Page 10: Cat6 Shielded Channel Performance - IEEE-SAgrouper.ieee.org/groups/802/3/10GBT/public/sep03/vaden_1_0903.pdf · Microsoft PowerPoint - Vaden_091003_Shielded_Cat6.ppt Author: savaden

Power Sum ANEXTAlien Power Sum NEXT

-100

-90

-80

-70

-60

-50

-40

-30

-20

0 100 200 300 400 500 600

Frequency, MHz

Alie

n P

ower

Sum

NE

XT,

dB

SolarFlare Proposed

Page 11: Cat6 Shielded Channel Performance - IEEE-SAgrouper.ieee.org/groups/802/3/10GBT/public/sep03/vaden_1_0903.pdf · Microsoft PowerPoint - Vaden_091003_Shielded_Cat6.ppt Author: savaden

Alien FEXT (ELFEXT)Alie n F E X T

-1 4 0

-1 2 0

-1 0 0

-8 0

-6 0

-4 0

-2 0

00 1 0 0 2 0 0 3 0 0 4 0 0 5 0 0 6 0 0

S 1 5 d BS 1 6 d BS 1 7 d BS 1 8 d BS 2 5 d BS 2 6 d BS 2 7 d BS 2 8 d BS 3 5 d BS 3 6 d BS 3 7 d BS 3 8 d BS 4 5 d BS 4 6 d BS 4 7 d BS 4 8 d B

Page 12: Cat6 Shielded Channel Performance - IEEE-SAgrouper.ieee.org/groups/802/3/10GBT/public/sep03/vaden_1_0903.pdf · Microsoft PowerPoint - Vaden_091003_Shielded_Cat6.ppt Author: savaden

Conclusions• The Cat6 shielded (SSTP) channel supports

20 Gbit (or better) Shannon capacity over 100 meter channel

• Alien NEXT and Alien FEXT (ELFEXT) are at or below measurable levels for much of the frequency range.

• Port-to-port isolation will be an important design parameter for 10G BASE-T transceivers