catalog no. date project type k4sa | 4 led new ...8' 13.2 9.8 10' 8.4 12.3 12' 5.9...

5
DATE PROJECT TYPE CATALOG NO. REV1220 CONTECH LIGHTING | 725 LANDWEHR ROAD | NORTHBROOK, ILLINOIS 60062 | PHONE 847.559.5500 | www.contechlighting.com © 2020 Conservation Technology of Illinois, LLC. All rights reserved. Note: Specifications subject to change without notice. K4SA | 4" LED New Construction Non-IC StopAire Downlight 9" 6-1/2" 11-1/4" 9" 4-3/16" 4" 1/2" 1. Lumen values are approximate, see photometric test results WATTAGE LUMEN OUTPUT 1 COLOR TEMPERATURE CRI SYSTEM RATING DRIVER INPUT WATTAGE DRIVER INPUT CURRENT (A) 120/277 DRIVER INPUT VOLTAGE 120V Dimming (Triac, ELV, 0-10V) 277V Dimming (0-10V) Lutron HiLume ® Dimming Lutron EcoSystem ® Dimming DRIVER Power Factor THD LISTING WARRANTY 10W 14W 20W 700Lm 900Lm 1200Lm 2700K, 3000K, 3500K, 4000K 90+ 50,000 Hours @ 70% Lumen Maintenance 10W 14W 20W .08/.04 .12/.05 .17/.07 120V AC, 50/60Hz 277V AC, 50/60Hz 120V AC, 50/60Hz 120-277V AC, 50/60Hz > 0.90 < 20% cCSAus Certified to UL Standards Suitable for damp locations The following combinations are ENERGY STAR ® Certified: – LED Series 1: Flood Beam, Standard Housing with Chicago Plenum and Emergency Battery Back-up options using CTR2002 (-PL-P, -CLR-P, -WHT-P), CTR2001-P and CTR2001W-P trims only – LED Series 1: Wide Beam, Standard Housing with Chicago Plenum and Emergency Battery Back-up options using CTR2002 (-PL-P, -CLR-P, -WHT-P) and CTR2001W-P trims only – LED Series 2: Flood Beam, Standard Housing with Chicago Plenum and Emergency Battery Back-up options using CTR2002 (-PL-P, -CLR-P, -WHT-P) and CTR2001W-P trims only LED Series 3: Flood Beam, Standard Housing with Chicago Plenum and Emergency Battery Back-up options using CTR2002 (-PL-P, -CLR-P, -WHT-P), CTR2001W-P trims only – LED Series 2 and LED Series 3 Wide Beam are not Certified – Lutron options are not Certified Conforms to Washington State Energy code (WSEC) for low air infiltration. Tested in accordance with ASTM E283 (2.0 CFM or less). CP Housings are Chicago Plenum CCEA listed Five (5) Year Replacement after Date of Purchase P1 Ceiling Opening: 4-3/8" Ceiling Thickness: 1/2" – 1-1/2"

Upload: others

Post on 20-Jan-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CATALOG NO. DATE PROJECT TYPE K4SA | 4 LED New ...8' 13.2 9.8 10' 8.4 12.3 12' 5.9 14.8 14' 4.3 17.2 16' 3.3 19.7 Fixture Delivered Lumens: 974.3 Total Watts@120V: 19.7 Lumens Per

DATE PROJECT TYPE

CATALOG NO.

REV1220

CONTECH LIGHTING | 725 LANDWEHR ROAD | NORTHBROOK, ILLINOIS 60062 | PHONE 847.559.5500 | www.contechlighting.com© 2020 Conservation Technology of Illinois, LLC. All rights reserved. Note: Specifications subject to change without notice.

K4SA | 4" LED New Construction Non-IC StopAire Downlight

9"

6-1/2"

11-1/4"

9"

4-3/16"

4"

1/2"1. Lumen values are approximate, see photometric test results

WATTAGE

LUMEN OUTPUT1

COLOR TEMPERATURE

CRI

SYSTEM RATING

DRIVER INPUT WATTAGE

DRIVER INPUT CURRENT (A) 120/277

DRIVER INPUT VOLTAGE120V Dimming (Triac, ELV, 0-10V)

277V Dimming (0-10V)Lutron HiLume® Dimming

Lutron EcoSystem® Dimming

DRIVERPower Factor

THD

LISTING

WARRANTY

10W 14W 20W

700Lm 900Lm 1200Lm

2700K, 3000K, 3500K, 4000K

90+

50,000 Hours @ 70% Lumen Maintenance

10W 14W 20W

.08/.04 .12/.05 .17/.07

120V AC, 50/60Hz277V AC, 50/60Hz120V AC, 50/60Hz120-277V AC, 50/60Hz

> 0.90< 20%

cCSAus Certified to UL StandardsSuitable for damp locationsThe following combinations are ENERGY STAR® Certified:

– LED Series 1: Flood Beam, Standard Housing with Chicago Plenum and Emergency Battery Back-up options using CTR2002 (-PL-P, -CLR-P, -WHT-P), CTR2001-P and CTR2001W-P trims only

– LED Series 1: Wide Beam, Standard Housing with Chicago Plenum and Emergency Battery Back-up options using CTR2002 (-PL-P, -CLR-P, -WHT-P) and CTR2001W-P trims only

– LED Series 2: Flood Beam, Standard Housing with Chicago Plenum and Emergency Battery Back-up options using CTR2002 (-PL-P, -CLR-P, -WHT-P) and CTR2001W-P trims only

– LED Series 3: Flood Beam, Standard Housing with Chicago Plenum and Emergency Battery Back-up options using CTR2002 (-PL-P, -CLR-P, -WHT-P), CTR2001W-P trims only

– LED Series 2 and LED Series 3 Wide Beam are not Certified– Lutron options are not Certified

Conforms to Washington State Energy code (WSEC) for low air infiltration. Tested in accordance with ASTM E283 (2.0 CFM or less).CP Housings are Chicago Plenum CCEA listed

Five (5) Year Replacement after Date of Purchase

P1

Ceiling Opening: 4-3/8"Ceiling Thickness: 1/2" – 1-1/2"

Page 2: CATALOG NO. DATE PROJECT TYPE K4SA | 4 LED New ...8' 13.2 9.8 10' 8.4 12.3 12' 5.9 14.8 14' 4.3 17.2 16' 3.3 19.7 Fixture Delivered Lumens: 974.3 Total Watts@120V: 19.7 Lumens Per

DATE PROJECT TYPE

CATALOG NO.

REV1220

CONTECH LIGHTING | 725 LANDWEHR ROAD | NORTHBROOK, ILLINOIS 60062 | PHONE 847.559.5500 | www.contechlighting.com© 2020 Conservation Technology of Illinois, LLC. All rights reserved. Note: Specifications subject to change without notice.

K4SA | 4" LED New Construction Non-IC StopAire Downlight

Options CP3 - Chicago PlenumER4 - Factory Installed 7W/200mA Emergency Battery Backup (Remote Test Switch)

1. TRIAC and ELV dimming for 120V only.2. Lutron Hi-Lume dimming only available in 120V.3. Chicago Plenum option is not available with D3 or D4 dimming. Chicago Plenum option cannot be used with Emergency Battery Backup option.4. Emergency Battery Backup option: 640 Lumen nominal average for either Series 1, 2, or 3

P2

Ordering Information

Housing/LED SeriesK4SA1 - 10W 700lm K4SA2 - 14W 900lmK4SA3 - 20W 1200lm

Electrical/DimmingMVD1 - Triac, ELV, 0-10V12D32 - Lutron Hi-Lume 1% 2-Wire LED Driver (120V Forward Phase Only)MVD4 - Lutron Hi-Lume 1% EcoSystem LED Driver with Soft-on, Fade-to-Black

Beam DistributionF - FloodW - Wide Flood

Example Order: K4SA127KCMVDW

Replacement Optics and AccessoriesStandard Hanger Bars Supplied with Housing HB-30 - 30" T-Bar Hanger SetK4OPTF - Flood Optic K4OPTW - Wide Flood Optic

Features• Aluminum housing with galvanized steel mounting frame; requires

minimum 3" clearance around fixture from insulation material. Thermal protection provided in case of improper insulation use.

• Output over-voltage, over-current and short circuit protection• Through-circuit wiring: max: (8) #12 AWG (4 in/4 out). Wiring

should be rated for at least 90°C. Chicago Plenum (CP) option is not approved for through-circuit wiring.

• Engineered optical system consists of a thermo-plastic optical housing, aluminum reflector and highly transmissive diffusion lens

• Light engine consists of a single, high output multi-chip LED array• Excellent fixture to fixture color consistency within a 3-step

MacAdam Ellipse tolerance• Many trim options available to complement any design style

Performance Summary• System provides a smooth uniform beam while eliminating view of

LED array. Two beam distributions are available. Optics are field interchangeable

• All K4SA LED downlights are available for non-dimming and dimming applications; for a list of compatible dimmers, refer to LED Dimming Specification Sheet

• The following combinations are ENERGY STAR® Certified:– LED Series 1: Flood Beam, Standard Housing with Chicago Plenum and

Emergency Battery Back-up options using CTR2002 (-PL-P, -CLR-P, -WHT-P), CTR2001-P and CTR2001W-P trims only

– LED Series 1: Wide Beam, Standard Housing with Chicago Plenum and Emergency Battery Back-up options using CTR2002 (-PL-P, -CLR-P, -WHT-P) and CTR2001W-P trims only

– LED Series 2: Flood Beam, Standard Housing with Chicago Plenum and Emergency Battery Back-up options using CTR2002 (-PL-P, -CLR-P, -WHT-P) and CTR2001W-P trims only

– LED Series 3: Flood Beam, Standard Housing with Chicago Plenum and Emergency Battery Back-up options using CTR2002 (-PL-P, -CLR-P, -WHT-P), CTR2001W-P trims only

– LED Series 2 and LED Series 3 Wide Beam are not Certified– Lutron options are not Certified

• Conforms to Washington State Energy Code (WSEC) for low air infiltration; tested in accordance with ASTM E283 (2.0 CFM or less)

• CP Housings are Chicago Plenum CCEA listed• Assembled in the USA

Warranty• This complete fixture is covered by ConTech’s full five (5) year

replacement guarantee after date of purchase• Emergency Battery option is covered by a one (1) year replacement

guarantee after date of purchase

Product Details

Color TempHigh CRI 90+ 27KC - 2700K30KC - 3000K35KC - 3500K40KC - 4000K

Page 3: CATALOG NO. DATE PROJECT TYPE K4SA | 4 LED New ...8' 13.2 9.8 10' 8.4 12.3 12' 5.9 14.8 14' 4.3 17.2 16' 3.3 19.7 Fixture Delivered Lumens: 974.3 Total Watts@120V: 19.7 Lumens Per

Trims for K4 Series LED Recessed Downlights

CTR2001SeriesBaffled Downlight3-1/2" I.D, 4-7/8" O.D.

All steel construction. (3) heat treated spring steel mounting clips. Black socket aiming bracket with screws (provided in carton).

CTR2005-P*Pin Spot, White1" I.D, 4-7/8" O.D.

All steel construction. Aluminum reflector. (3) heat treated spring steel mounting clips. Black socket aiming bracket with screws (provided in carton).

CTR2003-P*Scoop Wall Wash, White4-7/8" O.D., 1-1/2" x 3-1/2" Aperture

All steel construction. (3) heat treated spring steel mounting clips. Black socket aiming bracket with screws (provided in carton).

CTR2002 SeriesAluminum Reflector3-1/2" I.D, 4-7/8" O.D.

Aluminum reflector and steel trim ring. (3) heat treated spring steel mounting clips. Black socket aiming bracket with screws (provided in carton).

CTR2011FR Series*Flat Frosted Glass Lens Shower Light3-1/2" I.D, 4-15/16" O.D.

Wet location listed. All steel construction. (3) heat treated spring steel mounting clips. 1/8" thick heavy duty polyethylene sponge gasket.

CTR2012-P*Flat Alabite Glass Lens Shower Light, White Trim Ring3-5/8" I.D, 4-7/8" O.D.

Wet location listed. All steel construction. (3) heat treated spring steel mounting clips. 1/8" thick heavy duty polyethylene sponge gasket.

CTR2001-P Black Baffle

White Trim Ring

CTR2001W-PWhite Baffle

White Trim Ring

CTR2002-BLK-B Black Specular Aluminum Reflector

Black Trim Ring

CTR2002-CLR-P Clear Specular Aluminum Reflector

White Trim Ring

CTR2002-PL-P Platinum Aluminum Reflector

White Trim Ring

CTR2002-WHT-P White Specular Aluminum Reflector

White Trim Ring

CTR2011FR-NKBrushed Nickel Finish

CTR2011FR-PWhite Finish

*Not compatible with K4IC2 or K4ICR2 (LED Series 2)

DATE PROJECT TYPE

CATALOG NO.

REV1220

CONTECH LIGHTING | 725 LANDWEHR ROAD | NORTHBROOK, ILLINOIS 60062 | PHONE 847.559.5500 | www.contechlighting.com© 2020 Conservation Technology of Illinois, LLC. All rights reserved. Note: Specifications subject to change without notice.

Page 4: CATALOG NO. DATE PROJECT TYPE K4SA | 4 LED New ...8' 13.2 9.8 10' 8.4 12.3 12' 5.9 14.8 14' 4.3 17.2 16' 3.3 19.7 Fixture Delivered Lumens: 974.3 Total Watts@120V: 19.7 Lumens Per

DATE PROJECT TYPE

CATALOG NO.

REV1220

CONTECH LIGHTING | 725 LANDWEHR ROAD | NORTHBROOK, ILLINOIS 60062 | PHONE 847.559.5500 | www.contechlighting.com© 2020 Conservation Technology of Illinois, LLC. All rights reserved. Note: Specifications subject to change without notice.

K4SA | 4" LED New Construction Non-IC StopAire Downlight

0 90°

15°0° 30°

45°620

380

900

75°

60°

0 90°

15°0° 30°

45°1700

1000

2500

75°

60°

Candela Curve

Wavelength (nm)380 410 440 470 500 530 560 590 620 650 680 710 740 770

20

10

0

Wavelength (nm)380 410 440 470 500 530 560 590 620 650 680 710 740 770

20

10

0

Lumen output values fluctuate based on CCT. To estimate lumen output of the various CCT options, multiply 3000K results by the following:

Photometrics

Photometric Multiplication Factors

Intensity Distribution BEAM DISTANCE FOOTCANDLES DIAMETER (FT.) (FC) (FT.)

6' 58.8 4.1

8' 33.1 5.5

10' 21.2 6.9

12' 14.7 8.3

14' 10.8 9.6

16' 8.3 11.0

K4SA330KCMVDF/CTR2002-CLR-PFixture Delivered Lumens: 1269\.1Total Watts@120V: 19.7Lumens Per Watt: 64.4Center Beam Candle Power: 2118Beam Distribution: 38°Spacing Criterion: 0.70Color Rendering Index (CRI)1: 91Color Temperature (CCT)2: 3146KDesigned for 50,000 Hour Lamp Life3

LM-63 Test No. G20070201LM-79 Test No. S20070601

Candela Curve Spectral Power Distribution Chart4

Intensity Distribution

BEAM DISTANCE FOOTCANDLES DIAMETER (FT.) (FC) (FT.)

6' 23.5 7.4

8' 13.2 9.8

10' 8.4 12.3

12' 5.9 14.8

14' 4.3 17.2

16' 3.3 19.7

Fixture Delivered Lumens: 974.3Total Watts@120V: 19.7Lumens Per Watt: 49.5Center Beam Candle Power: 844Beam Distribution: 63°Spacing Criterion: 0.95Color Rendering Index (CRI)2: 91Color Temperature (CCT)3: 3075KDesigned for 50,000 Hour Lamp Life3

LM-63 Test No. G20070208LM-79 Test No. S20070602

K4SA330KCMVDW/CTR2002-PL-PSpectral Power Distribution Chart4

1. Accuracy of rendering colors 2. Color appearance of light source 3. Dependent on surrounding temperatures 4. Colors present within the light source

CCT SERIES 1 SERIES 2

2700K 0.90 0.57 0.76

3000K 1.0 0.57 0.76

3500K N/A 0.57 0.76

4000K 1.08 0.57 0.76

P3

Page 5: CATALOG NO. DATE PROJECT TYPE K4SA | 4 LED New ...8' 13.2 9.8 10' 8.4 12.3 12' 5.9 14.8 14' 4.3 17.2 16' 3.3 19.7 Fixture Delivered Lumens: 974.3 Total Watts@120V: 19.7 Lumens Per

K4 SERIES* K6 SERIES* Dimming Options MVD Dimming Range

Manufacturer Product Model Light Output

Leviton IllumaTech IPL06-10z 3%-100%

Leviton IllumaTech IPI06-1LZ 17%-100%

Leviton SureSlide R62-6674 17%-100%

Leviton SureSlide R62-6633 >1%-100%

Lutron Skylark NT-600 >1%-100%

Lutron Diva DV600P 1%-100%

Lutron Diva DVLV-600P 3%-100%

Lutron D-600P 3%-100%

Lutron Diva DVCL-153P 2%-100%

Lutron Maestro MACL-153M 3%-100%

Cooper R1061-LA 7%-100%

Cooper Devine DAL06P-C1 >1%-100%

Cooper TAL06P-C1 >1%-100%

Cooper SAL06p >1%-100%

Cooper Decorator DAL06P-C2 >1%-100%

*277V Triac Dimming is not available

• Incandescent 120VAC dimmers adjust the light with “forward phase control”, where the dimmer “chops” the forward part of the AC wave to deliver less or more power to the light source. No neutral wire connection required.

• Electronic vow voltage 120VAC dimmers adjust the light with “reverse phase control,” where the dimmer “chops” the back part of the AC wave to deliver less or more power to the light source. Neutral wire connection required.

• 0-10V DC low voltage dimmers operate using two low voltage dimming wires that are separate from the 120V or 277V AC power. The dimmer sends a variable output voltage to the fixture based upon the dimming level. 10V corresponds to undimmed operation, 5V to 50% and so on. Switching on/off is controlled with the line voltage power (120V or 277V AC) input to the dimmer and then dimming operation is controlled with the 0-10V DC low voltage wiring connection between the dimmer and the LED driver. The control signal runs on two low voltage control wires (color coded violet and gray).

• Lutron HiLume and EcoSystem dirvers provide continuous dimming from 1%-100%. For a complete list of compatible dimmers and controls, please visit www.lutron.com

DIMMING SPECIFICATIONS | K4 and K6 Series

Notes1. Testing was performed with a single fixture connected to dimmer. 2. Testing has been performed on these dimmers, but this does not imply any warranty of compatibility. 3. Dimming performance can be influenced by different loads, as well as variations in dimmer switches within the same model. 4. Dimmer maximum load rating with LED may differ from published traditional source dimmer ratings. Consult manufacturer for maximum dimmer information.5. Consult factory for additional dimming information.

REV1020

CONTECH LIGHTING | 725 LANDWEHR ROAD | NORTHBROOK, ILLINOIS 60062 | PHONE 847.559.5500 | www.contechlighting.com© 2020 Conservation Technology of Illinois, LLC. All rights reserved. Note: Specifications subject to change without notice.

DATE PROJECT TYPE

CATALOG NO.