catalogo cables radiantes, leaky radiating cables
TRANSCRIPT
Radiating and Coupling Cable Systems Radiating cables are used wherever normal radio communication is difficult or impossible, in particular in communication systems where a discrete antenna would not provide adequate coverage, such as in tunnels, underground railways, mines, buildings, etc. RF energy is simultaneously transmitted down radiating cables and radiated from all points along them into the surrounding space. Slots cut into the outer conductor of the coaxial cable allow controlled levels of electromagnetic energy to be radiated both out of and into the cable.
Cables Characteristics Radiating Cable 1/2" Radiating Leaky Feeder Slexrtd RF 450-2600 MHz Radiating Cable 1/2" Radiating Leaky Feeder Silexrtd RF 150-900 MHz Radiating Cable 1/2" Coupling Leaky Feeder Silexrtd RF 75-2400 MHz Radiating Cable 1/2" Coupling2 Leaky Feeder Silexrtd RF 75-2400 MHz Radiating Cable 7/8" Radiating Leaky Feeder Slexrtd RF 75-2700 MHz Radiating Cable 7/8" Radiating Leaky Feeder Slexrtd RF 75-960 MHz Radiating Cable 7/8" Coupling Leaky Feeder Slexrtd RF 75-2400 MHz Radiating Cable 7/8" Coupling2 Leaky Feeder Slexrtd RF 75-2400 MHz Radiating Cable 1-1/4" Radiating Leaky Feeder Slexrtd RF 75-2700 MHz Radiating Cable 1-1/4" Radiating Leaky Feeder Slexrtd RF 75-960 MH Radiating Cable 1-1/4" Coupling Leaky Feeder Slexrtd RF 75-2400 MHz Radiating Cable 1-5/8" Radiating Leaky Feeder Slexrtd RF 75-2700 MHz Radiating Cable 1-5/8" Radiating Leaky Feeder Slexrtd RF 75-2500 MHz Radiating Cable 1-5/8" Radiating Leaky Feeder Slexrtd RF 75-960 MHz Radiating Cable 1-5/8" Coupling Leaky Feeder Slexrtd RF 75-2400 MHz Connectors Systems Radiating Connector DIN 7/16 Type Radiating Connector N Type
Radiating Clamp Systems Fix Metalic System Camp Plastic System Camp
Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.
See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com
RADIATING COAXIAL CABLE
Leaky Cable
Radiating cables facilitate radio communication where the usual free space propagation of electromagnetic waves is hampered, undesired or impossible- in tunnels, mines, buildings, alongside tracks or lines and in large complexes like exhibition grounds or airports. Our Radiating series focus on some Specific band which can provide an optimized performance. They are popularly used in GSM/CDMA/UMTS system.
RCF12R26(Z)(R)
Coaxial Radiating Cable, Broadband from 450 –2600 MHz, 1/2 in, Low smoke, black non-halogenated or fire retardant polyolefin jacket. Type HLCAY(Z)(R)-50-12(1/2"C)
PHYSICAL DIMENSIONS CONSTRUCTION MATERIALS
Nominal Size 1/2" Inner Conductor Diameter 4.80 mm | 0.1890" Dielectric Diameter 12.30 mm | 0.4843" Outer Conductor Diameter 12.60 mm | 0.4961" Diameter Over Jacket 15.50 mm | 0.6102"
Inner Conductor Copper-Clad Aluminum Wire Dielectric Physical Foam Polyethylene Outer Conductor Overlapping Copper Foil Jacket Black PE or Low Smoke Halogen-free Fire-retardant Jacket Color Black
MECHANICAL SPECIFICATIONS
Single Bending radius 125 mm Multiple bending radius 350 mm Minimum Distance to Wall 50 mm Tensile Strength 1000 N Bending Moment 13.5N.m Flat Plate Crush Strength 200kg/m Recommended Hanger Spacing 0.8~1.2m Fire Retardancy Test Method IEC 60332-1 | IEC 60332-3C-24 Smoke Index Test Method IEC 61034 Toxicity Index Test Method IEC 60754-1 & | IEC 60754-1
ENVIRONMENTAL SPECIFICATION STANDARD CONDITION
Storage Temperature -55 ℃ ~ +85 ℃ Installation Temperature -40 ℃ ~ +80 ℃ Operating Temperature -55 ℃ ~ +85 ℃ Relative Humidity 95% ROHS YES
As with any radiating cable, the performance in building or tunnel environments may deviate from figures based on free space method Due to the cable design, single lengths should not be less than 80m (262ft)
Attenuation Test Method IEC 61196-4 Attenuation Tolerance ±10% Attenuation ,Ambient Temperature 20℃ | 68℉ Coupling Loss Test Method IEC 61196-4 Coupling Loss Tolerance ±5dB
Coupling loss values are given with a tolerance of ±5 dB and longitudinal loss values with a tolerance of ±5%.
Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.
See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com
RADIATING COAXIAL CABLE
Leaky Cable
ELECTRICAL SPECIFICATIONS
Capacitance
75.0 pF/m Impedance
50±2 Ω
Velocity
86% Insulation Resistance
>5000 MΩ•km
Jacket Spark
8 KV Insulation Voltage
6 KV
Inner Conductor DC Resistance
1.60 Ω/km Outer Conductor DC Resistance
4.30 Ω/km
Stop Band
1012~1052MHz & 2025~2110MHz Operating Frequency Band
700~2700 MHz
VSWR 800~960 MHz
≤1.30 1700~2025 MHz
≤1.40
2110~2170 MHz
≤1.40 2300~2700 MHz
≤1.40
ELECTRICAL PERFORMANCE
Frequency Attenuation Coupling Loss
(2m) MHz dB/100 m dB/100 ft 50%(dB) 95%(dB)
450 005 1,58 82 90 800 007 2,19 69 73 900 008 2,35 68 72
1800 012 3,63 65 68 2000 013 3,96 67 70 2100 014 4,18 65 69 2200 014 4,27 65 68 2400 016 4,72 63 66 2600 016 4,91 64 68
Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.
See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com
RADIATING COAXIAL CABLE
Leaky Cable
Radiating cables facilitate radio communication where the usual free space propagation of electromagnetic waves is hampered, undesired or impossible- in tunnels, mines, buildings, alongside tracks or lines and in large complexes like exhibition grounds or airports.
RLK12R9(Z)(R)
Coaxial Radiating Cable, Broadband from 150 –900 MHz, 1/2 in, Low smoke, black non-halogenated or fire retardant polyolefin jacket. Type HLCAY(Z)(R)-50-12(1/2"D)
PHYSICAL DIMENSIONS CONSTRUCTION MATERIALS
Nominal Size 1/2" Inner Conductor Diameter 4.80 mm | 0.1890" Dielectric Diameter 12.30 mm | 0.4843" Outer Conductor Diameter 12.60 mm | 0.4961" Diameter Over Jacket 15.50 mm | 0.6102"
Inner Conductor Copper-Clad Aluminum Wire Dielectric Physical Foam Polyethylene Outer Conductor Overlapping Copper Foil Jacket Black PE or Low Smoke Halogen-free Fire-retardant Jacket Color Black
MECHANICAL SPECIFICATIONS
Single Bending radius 125 mm Multiple bending radius 350 mm Minimum Distance to Wall 50 mm Tensile Strength 1000 N Bending Moment 13.5N.m Flat Plate Crush Strength 200kg/m Recommended Hanger Spacing 0.8~1.2m Fire Retardancy Test Method IEC 60332-1 | IEC 60332-3C-24 Smoke Index Test Method IEC 61034 Toxicity Index Test Method IEC 60754-1 & | IEC 60754-1
ENVIRONMENTAL SPECIFICATION STANDARD CONDITION
Storage Temperature -55 ℃ ~ +85 ℃ Installation Temperature -40 ℃ ~ +80 ℃ Operating Temperature -55 ℃ ~ +85 ℃ Relative Humidity 95% ROHS YES
As with any radiating cable, the performance in building or tunnel environments may deviate from figures based on free space method Due to the cable design, single lengths should not be less than 80m (262ft)
Attenuation Test Method IEC 61196-4 Attenuation Tolerance ±10% Attenuation ,Ambient Temperature 20℃ | 68℉ Coupling Loss Test Method IEC 61196-4 Coupling Loss Tolerance ±5dB
Coupling loss values are given with a tolerance of ±5 dB and longitudinal loss values with a tolerance of ±5%.
Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.
See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com
RADIATING COAXIAL CABLE
Leaky Cable
ELECTRICAL SPECIFICATIONS
Capacitance
75.0 pF/m Impedance
50±2 Ω
Velocity
88% Insulation Resistance
>5000 MΩ•km
Jacket Spark
8 KV Insulation Voltage
6 KV
Inner Conductor DC Resistance
1.48 Ω/km Outer Conductor DC Resistance
3.40 Ω/km
VSWR
0.3 ~ 0.5 GHz
≤1.30
0.8 ~ 1.0 GHz
≤1.30
ELECTRICAL PERFORMANCE
Frequency Attenuation
Coupling Loss
(2m) MHz dB/100 m
50%(dB) 95%(dB)
150 3.30
62 70 450 5.90
65 70
800 8.40
64 70 900 9.10
63 70
Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.
See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com
RADIATING COAXIAL CABLE
Leaky Cable
Radiating cables facilitate radio communication where the usual free space propagation of electromagnetic waves is hampered, undesired or impossible- in tunnels, mines, buildings, alongside tracks or lines and in large complexes like exhibition grounds or airports. Our coupling series can support all major services from 75 MHz to 3 GHz and is therefore optimally suited for multi-operator and multi-band applications.
RCF12C24(Z)
Coaxial Radiating Cable, Broadband from 75 –2400 MHz, 1/2 in, Low smoke, black non-halogenated or fire retardant polyolefin jacket. Type HLCAY(Z)-50-12(1/2")
PHYSICAL DIMENSIONS CONSTRUCTION MATERIALS
Nominal Size 1/2" Inner Conductor Diameter 4.80 mm | 0.1890" Dielectric Diameter 12.30 mm | 0.4843" Outer Conductor Diameter 13.80 mm | 0.4961" Diameter Over Jacket 15.70 mm | 0.6102"
Inner Conductor Copper-Clad Aluminum Wire Dielectric Physical Foam Polyethylene Outer Conductor Overlapping Copper Foil Jacket Black PE or Low Smoke Halogen-free Fire-retardant Jacket Color Black
MECHANICAL SPECIFICATIONS
Single Bending radius 50mm Multiple bending radius 350 mm Minimum Distance to Wall 50 mm Tensile Strength 1000 N Bending Moment 13.5N.m Flat Plate Crush Strength 200kg/m Recommended Hanger Spacing 0.8~1.2m Fire Retardancy Test Method IEC 60332-1 | IEC 60332-3C-24 Smoke Index Test Method IEC 61034 Toxicity Index Test Method IEC 60754-1 & | IEC 60754-1
ENVIRONMENTAL SPECIFICATION STANDARD CONDITION
Storage Temperature -55 ℃ ~ +85 ℃ Installation Temperature -40 ℃ ~ +80 ℃ Operating Temperature -55 ℃ ~ +85 ℃ Relative Humidity 95% ROHS YES
As with any radiating cable, the performance in building or tunnel environments may deviate from figures based on free space method Due to the cable design, single lengths should not be less than 80m (262ft)
Attenuation Test Method IEC 61196-4 Attenuation Tolerance ±10% Attenuation ,Ambient Temperature 20℃ | 68℉ Coupling Loss Test Method IEC 61196-4 Coupling Loss Tolerance ±5dB
Coupling loss values are given with a tolerance of ±5 dB and longitudinal loss values with a tolerance of ±5%.
Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.
See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com
RADIATING COAXIAL CABLE
Leaky Cable
ELECTRICAL SPECIFICATIONS
Capacitance
76.0 pF/m Impedance
50±2 Ω
Velocity
86% Insulation Resistance
>5000 MΩ•km
Jacket Spark
8 KV Insulation Voltage
6 KV
Inner Conductor DC Resistance
1.50 Ω/km Outer Conductor DC Resistance
3.00 Ω/km
Stop Band
- Operating Frequency Band
75~2400 MHz
VSWR 0.3~0.5 GHz
≤1.30 0.8~1.0 GHz
≤1.30
1.7~2.7GHz
≤1.30
ELECTRICAL PERFORMANCE
Frequency Attenuation COUPLING LOSS(2m) MHz dB/100 m dB/100 ft 50%(dB) 95%(dB)
75 2,1 0,6 69 77
150 3 0,9 70 80
450 5,5 1,7 70 80
800 7,5 2,3 72 83
900 8,1 2,5 72 83
1800 12,4 3,8 77 86
2200 13,9 4,2 78 87
2400 14,5 4,4 78 86
Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.
See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com
RADIATING COAXIAL CABLE
Leaky Cable
Radiating cables facilitate radio communication where the usual free space propagation of electromagnetic waves is hampered, undesired or impossible- in tunnels, mines, buildings, alongside tracks or lines and in large complexes like exhibition grounds or airports. Our coupling series can support all major services from 75 MHz to 3 GHz and is therefore optimally suited for multi-operator and multi-band applications.
RCF12C224(Z)
Coaxial Radiating Cable, Broadband from 75 –2400 MHz, 1/2 in, Low smoke, black non-halogenated or fire retardant polyolefin jacket. Type HLCAY(Z)-50-12(1/2")
PHYSICAL DIMENSIONS CONSTRUCTION MATERIALS
Nominal Size 1/2" Inner Conductor Diameter 4.80 mm | 0.1890" Dielectric Diameter 12.30 mm | 0.4843" Outer Conductor Diameter 13.80 mm | 0.4961" Diameter Over Jacket 15.70 mm | 0.6102"
Inner Conductor Copper-Clad Aluminum Wire Dielectric Physical Foam Polyethylene Outer Conductor Overlapping Copper Foil Jacket Black PE or Low Smoke Halogen-free Fire-retardant Jacket Color Black
MECHANICAL SPECIFICATIONS
Single Bending radius 50mm Multiple bending radius 350 mm Minimum Distance to Wall 50 mm Tensile Strength 1000 N Bending Moment 13.5N.m Flat Plate Crush Strength 200kg/m Recommended Hanger Spacing 0.8~1.2m Fire Retardancy Test Method IEC 60332-1 | IEC 60332-3C-24 Smoke Index Test Method IEC 61034 Toxicity Index Test Method IEC 60754-1 & | IEC 60754-1
ENVIRONMENTAL SPECIFICATION STANDARD CONDITION
Storage Temperature -55 ℃ ~ +85 ℃ Installation Temperature -40 ℃ ~ +80 ℃ Operating Temperature -55 ℃ ~ +85 ℃ Relative Humidity 95% ROHS YES
As with any radiating cable, the performance in building or tunnel environments may deviate from figures based on free space method Due to the cable design, single lengths should not be less than 80m (262ft)
Attenuation Test Method IEC 61196-4 Attenuation Tolerance ±10% Attenuation ,Ambient Temperature 20℃ | 68℉ Coupling Loss Test Method IEC 61196-4 Coupling Loss Tolerance ±5dB
Coupling loss values are given with a tolerance of ±5 dB and longitudinal loss values with a tolerance of ±5%.
Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.
See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com
RADIATING COAXIAL CABLE
Leaky Cable
ELECTRICAL SPECIFICATIONS
Capacitance
76.0 pF/m Impedance
50±2 Ω
Velocity
88% Insulation Resistance
>5000 MΩ•km
Jacket Spark
8 KV Insulation Voltage
6 KV
Inner Conductor DC Resistance
1.50 Ω/km Outer Conductor DC Resistance
3.10 Ω/km
Stop Band
- Operating Frequency Band
75~2400 MHz
VSWR 0.3~0.5 GHz
≤1.30 0.8~1.0 GHz
≤1.30
1.7~2.7GHz
≤1.30
ELECTRICAL PERFORMANCE
Frequency Attenuation COUPLING LOSS(2m) MHz dB/100 m dB/100 ft 50%(dB) 95%(dB)
75 2,1 0,63 66 76
150 03 0,94 67 78
450 5,7 1,74 67 78
800 7,9 2,41 71 80
900 8,2 2,5 70 80
1800 12,9 3,93 69 81
2200 14,5 4,42 72 82
2400 15,5 4,72 75 83
Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.
See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com
RADIATING COAXIAL CABLE
Leaky Cable
Radiating cables facilitate radio communication where the usual free space propagation of electromagnetic waves is hampered, undesired or impossible- in tunnels, mines, buildings, alongside tracks or lines and in large complexes like exhibition grounds or airports. Our Radiating series focus on some Specific band which can provide an optimized performance. They are popularly used in GSM/CDMA/UMTS system.
RCF78R27(Z)(R)
Coaxial Radiating Cable, Broadband from 75 –2700 MHz, 7/8” in, Low smoke, black non-halogenated or fire retardant polyolefin jacket. Type HLCTY(Z)(R)-50-23(7/8"C)
PHYSICAL DIMENSIONS CONSTRUCTION MATERIALS
Nominal Size 7/8" Inner Conductor Diameter 9.45 mm | 0.3720" Dielectric Diameter 22.80 mm | 0.8976" Outer Conductor Diameter 23.50 mm | 0.9370" Diameter Over Jacket 27.20 mm | 1.0709"
Inner Conductor Smooth Copper Tube Dielectric Physical Foam Polyethylene Outer Conductor Overlapping Copper Foil
Jacket Black PE or Low Smoke Halogen-free Fire-retardant
Jacket Color Black
MECHANICAL SPECIFICATIONS
Single Bending radius 250 mm Multiple bending radius 500 mm Minimum Distance to Wall 50 mm Tensile Strength 1350 N Bending Moment 14.9N.m Flat Plate Crush Strength 400kg/m Recommended Hanger Spacing 0.8~1.2m Fire Retardancy Test Method IEC 60332-1 | IEC 60332-3C-24 Smoke Index Test Method IEC 61034 Toxicity Index Test Method IEC 60754-1 & | IEC 60754-1
ENVIRONMENTAL SPECIFICATION STANDARD CONDITION
Storage Temperature -55 ℃ ~ +85 ℃ Installation Temperature -40 ℃ ~ +80 ℃ Operating Temperature -55 ℃ ~ +85 ℃ Relative Humidity 95% ROHS YES
As with any radiating cable, the performance in building or tunnel environments may deviate from figures based on free space method Due to the cable design, single lengths should not be less than 80m (262ft)
Attenuation Test Method IEC 61196-4 Attenuation Tolerance ±10% Attenuation ,Ambient Temperature 20℃ | 68℉ Coupling Loss Test Method IEC 61196-4 Coupling Loss Tolerance ±5dB
Coupling loss values are given with a tolerance of ±5 dB and longitudinal loss values with a tolerance of ±5%.
Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.
See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com
RADIATING COAXIAL CABLE
Leaky Cable
ELECTRICAL SPECIFICATIONS
Capacitance
75.0 pF/m Impedance
50±2 Ω
Velocity
89% Insulation Resistance
>5000 MΩ•km
Jacket Spark
8 KV Insulation Voltage
10 KV
Inner Conductor DC Resistance
1.80 Ω/km Outer Conductor DC Resistance
2.90 Ω/km
Stop Band
1012~1052MHz & 2025~2110MHz Operating Frequency Band
75~2700 MHz
Optimum Operating Frequency Band
700~2700 MHz VSWR
800~960 MHz
≤1.30 1700~2025 MHz
≤1.30
2110~2170 MHz
≤1.30 2300~2700 MHz
≤1.30
ELECTRICAL PERFORMANCE
Frequency Attenuation Coupling Loss (2m) MHz dB/100 m dB/100 ft 50%(dB) 95%(dB)
75 001 000 70 79 100 002 0,46 70 81 150 002 0,55 78 89 350 003 0,88 83 93 450 003 1,04 85 95 700 004 1,19 73 77 800 004 1,22 70 73 900 004 1,28 69 72
1800 007 1,98 65 68 1900 007 002 64 67 2200 008 2,38 63 66 2400 008 003 62 65 2600 009 2,87 62 66 2700 011 3,23 62 66
Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.
See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com
RADIATING COAXIAL CABLE
Leaky Cable
Radiating cables facilitate radio communication where the usual free space propagation of electromagnetic waves is hampered, undesired or impossible- in tunnels, mines, buildings, alongside tracks or lines and in large complexes like exhibition grounds or airports. Our Radiating series focus on some Specific band which can provide an optimized performance. They are popularly used in GSM/CDMA/UMTS system.
RLK78R10(Z)(R)
Coaxial Radiating Cable, Broadband from 75 –960 MHz, 7/8” in, Low smoke, black non-halogenated or fire retardant polyolefin jacket. Type HLCTY(Z)(R)-50-23(7/8"D)
PHYSICAL DIMENSIONS CONSTRUCTION MATERIALS
Nominal Size 7/8" Inner Conductor Diameter 9.45 mm | 0.3720" Dielectric Diameter 22.80 mm | 0.8976" Outer Conductor Diameter 23.20 mm | 0.9134" Diameter Over Jacket 27.20 mm | 1.0709"
Inner Conductor Smooth Copper Tube Dielectric Physical Foam Polyethylene Outer Conductor Overlapping Copper Foil
Jacket Black PE or Low Smoke Halogen-free Fire-retardant
Jacket Color Black
MECHANICAL SPECIFICATIONS
Single Bending radius 250 mm Multiple bending radius 500 mm Minimum Distance to Wall 50 mm Tensile Strength 1350 N Bending Moment 14.9N.m Flat Plate Crush Strength 400kg/m Recommended Hanger Spacing 0.8~1.2m Fire Retardancy Test Method IEC 60332-1 | IEC 60332-3C-24 Smoke Index Test Method IEC 61034 Toxicity Index Test Method IEC 60754-1 & | IEC 60754-1
ENVIRONMENTAL SPECIFICATION STANDARD CONDITION
Storage Temperature -55 ℃ ~ +85 ℃ Installation Temperature -40 ℃ ~ +80 ℃ Operating Temperature -55 ℃ ~ +85 ℃ Relative Humidity 95% ROHS YES
As with any radiating cable, the performance in building or tunnel environments may deviate from figures based on free space method Due to the cable design, single lengths should not be less than 80m (262ft)
Attenuation Test Method IEC 61196-4 Attenuation Tolerance ±10% Attenuation ,Ambient Temperature 20℃ | 68℉ Coupling Loss Test Method IEC 61196-4 Coupling Loss Tolerance ±5dB
Coupling loss values are given with a tolerance of ±5 dB and longitudinal loss values with a tolerance of ±5%.
Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.
See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com
RADIATING COAXIAL CABLE
Leaky Cable
ELECTRICAL SPECIFICATIONS
Capacitance
75.0 pF/m Impedance
50±2 Ω
Velocity
89% Insulation Resistance
>5000 MΩ•km
Jacket Spark
8 KV Insulation Voltage
10 KV
Inner Conductor DC Resistance
1.80 Ω/km Outer Conductor DC Resistance
3.00 Ω/km
Stop Band
180~280MHz & 500~580MHz Operating Frequency Band
75~1000 MHz
VSWR 800~960 MHz
≤1.30 1700~2025 MHz
≤1.30
2110~2170 MHz
≤1.30 2300~2700 MHz
≤1.30
ELECTRICAL PERFORMANCE
Frequency Attenuation Coupling Loss (2m) MHz dB/100 m dB/100 ft 50%(dB) 95%(dB)
75 001 000 60 70 100 002 0,49 62 65 150 002 0,58 63 73 350 003 0,91 62 65 450 004 1,07 66 71 650 004 1,25 61 68 800 005 1,43 60 62 900 005 1,52 58 61 960 005 1,62 57 60
Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.
See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com
RADIATING COAXIAL CABLE
Leaky Cable
Radiating cables facilitate radio communication where the usual free space propagation of electromagnetic waves is hampered, undesired or impossible- in tunnels, mines, buildings, alongside tracks or lines and in large complexes like exhibition grounds or airports. Our coupling series can support all major services from 75 MHz to 3 GHz and is therefore optimally suited for multi-operator and multi-band applications.
RCF78C24(Z)(R)
Coaxial Radiating Cable, Broadband from 75 –2400 MHz, 7/8 in, Low smoke, black non-halogenated or fire retardant polyolefin jacket. Type HLCTY(Z)-50-22(7/8")
PHYSICAL DIMENSIONS CONSTRUCTION MATERIALS
Nominal Size 7/8" Inner Conductor Diameter 9.00 mm | Dielectric Diameter 22.30 mm | Outer Conductor Diameter 24.90 mm | Diameter Over Jacket 27.50 mm |
Inner Conductor Smooth Copper Tube Dielectric Physical Foam Polyethylene Outer Conductor Overlapping Copper Foil Jacket Black PE or Low Smoke Halogen-free Fire-retardant Jacket Color Black
MECHANICAL SPECIFICATIONS
Single Bending radius 90mm Multiple bending radius 500 mm Minimum Distance to Wall 50 mm Tensile Strength 1470 N Bending Moment 14.9N.m Flat Plate Crush Strength 400kg/m Recommended Hanger Spacing 0.8~1.2m Fire Retardancy Test Method IEC 60332-1 | IEC 60332-3C-24 Smoke Index Test Method IEC 61034 Toxicity Index Test Method IEC 60754-1 & | IEC 60754-1
ENVIRONMENTAL SPECIFICATION STANDARD CONDITION
Storage Temperature -55 ℃ ~ +85 ℃ Installation Temperature -40 ℃ ~ +80 ℃ Operating Temperature -55 ℃ ~ +85 ℃ Relative Humidity 95% ROHS YES
As with any radiating cable, the performance in building or tunnel environments may deviate from figures based on free space method Due to the cable design, single lengths should not be less than 80m (262ft)
Attenuation Test Method IEC 61196-4 Attenuation Tolerance ±10% Attenuation ,Ambient Temperature 20℃ | 68℉ Coupling Loss Test Method IEC 61196-4 Coupling Loss Tolerance ±5dB
Coupling loss values are given with a tolerance of ±5 dB and longitudinal loss values with a tolerance of ±5%.
Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.
See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com
RADIATING COAXIAL CABLE
Leaky Cable
ELECTRICAL SPECIFICATIONS
Capacitance
76.0 pF/m Impedance
50±2 Ω
Velocity
86% Insulation Resistance
>5000 MΩ•km
Jacket Spark
8 KV Insulation Voltage
6 KV
Inner Conductor DC Resistance
1.65 Ω/km Outer Conductor DC Resistance
1.90 Ω/km
Stop Band
- Operating Frequency Band
75~2400 MHz
VSWR 0.3~0.5 GHz
≤1.30 0.8~1.0 GHz
≤1.30
1.7~2.7GHz
≤1.30
ELECTRICAL PERFORMANCE
Frequency Attenuation COUPLING LOSS(2m) MHz dB/100 m dB/100 ft 50%(dB) 95%(dB)
75 1,2 0,4 63 72
150 2 0,5 65 75
450 3,2 1 71 79
800 4,4 1,3 75 83
900 4,7 1,4 76 85
1800 7,1 2,2 77 87
2200 8 2,4 78 86
2400 8,9 2,7 77 87
Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.
See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com
RADIATING COAXIAL CABLE
Leaky Cable
Radiating cables facilitate radio communication where the usual free space propagation of electromagnetic waves is hampered, undesired or impossible- in tunnels, mines, buildings, alongside tracks or lines and in large complexes like exhibition grounds or airports. Our coupling series can support all major services from 75 MHz to 3 GHz and is therefore optimally suited for multi-operator and multi-band applications.
RCF78C224(Z)
Coaxial Radiating Cable, Broadband from 75 –2400 MHz, 7/8 in, Low smoke, black non-halogenated or fire retardant polyolefin jacket. Type HLCTY(Z)-50-22-2(7/8")
PHYSICAL DIMENSIONS CONSTRUCTION MATERIALS
Nominal Size 7/8" Inner Conductor Diameter 9.00 mm | Dielectric Diameter 22.30 mm | Outer Conductor Diameter 24.90 mm | Diameter Over Jacket 27.50 mm |
Inner Conductor Smooth Copper Tube Dielectric Physical Foam Polyethylene Outer Conductor Overlapping Copper Foil Jacket Black PE or Low Smoke Halogen-free Fire-retardant Jacket Color Black
MECHANICAL SPECIFICATIONS
Single Bending radius 90mm Multiple bending radius 500 mm Minimum Distance to Wall 50 mm Tensile Strength 1470 N Bending Moment 14.9N.m Flat Plate Crush Strength 400kg/m Recommended Hanger Spacing 0.8~1.2m Fire Retardancy Test Method IEC 60332-1 | IEC 60332-3C-24 Smoke Index Test Method IEC 61034 Toxicity Index Test Method IEC 60754-1 & | IEC 60754-1
ENVIRONMENTAL SPECIFICATION STANDARD CONDITION
Storage Temperature -55 ℃ ~ +85 ℃ Installation Temperature -40 ℃ ~ +80 ℃ Operating Temperature -55 ℃ ~ +85 ℃ Relative Humidity 95% ROHS YES
As with any radiating cable, the performance in building or tunnel environments may deviate from figures based on free space method Due to the cable design, single lengths should not be less than 80m (262ft)
Attenuation Test Method IEC 61196-4 Attenuation Tolerance ±10% Attenuation ,Ambient Temperature 20℃ | 68℉ Coupling Loss Test Method IEC 61196-4 Coupling Loss Tolerance ±5dB
Coupling loss values are given with a tolerance of ±5 dB and longitudinal loss values with a tolerance of ±5%.
Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.
See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com
RADIATING COAXIAL CABLE
Leaky Cable
ELECTRICAL SPECIFICATIONS
Capacitance
76.0 pF/m Impedance
50±2 Ω
Velocity
86% Insulation Resistance
>5000 MΩ•km
Jacket Spark
8 KV Insulation Voltage
10 KV
Inner Conductor DC Resistance
1.65 Ω/km Outer Conductor DC Resistance
2.10 Ω/km
Stop Band
- Operating Frequency Band
75~2400 MHz
VSWR 0.3~0.5 GHz
≤1.30 0.8~1.0 GHz
≤1.30
1.7~2.7GHz
≤1.30
ELECTRICAL PERFORMANCE
Frequency Attenuation COUPLING LOSS(2m) MHz dB/100 m dB/100 ft 50%(dB) 95%(dB)
75 1,2 0,4 63 72
150 2 0,5 65 75
450 3,2 1 71 79
800 4,4 1,3 75 83
900 4,7 1,4 76 85
1800 7,1 2,2 77 87
2200 8 2,4 78 86
2400 8,9 2,7 77 87 Maximum attenuation value shall be 105% of the nominal attenuation value
Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.
See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com
RADIATING COAXIAL CABLE
Leaky Cable
Radiating cables facilitate radio communication where the usual free space propagation of electromagnetic waves is hampered, undesired or impossible- in tunnels, mines, buildings, alongside tracks or lines and in large complexes like exhibition grounds or airports. Our Radiating series focus on some Specific band which can provide an optimized performance. They are popularly used in GSM/CDMA/UMTS system.
RCF114R27(Z)(R)
Coaxial Radiating Cable, Broadband from 75 –2700 MHz, 1-1/4” in, Low smoke, black non-halogenated or fire retardant polyolefin jacket. Type HLCTY(Z)(R)-50-32(1-1/4"C)
PHYSICAL DIMENSIONS CONSTRUCTION MATERIALS
Nominal Size 1-1/4" Inner Conductor Diameter 13.00 mm | 0.5118" Dielectric Diameter 32.80 mm | 1.2913" Outer Conductor Diameter 33.20 mm | 1.3071" Diameter Over Jacket 37.80 mm | 1.5039"
Inner Conductor Smooth Copper Tube Dielectric Physical Foam Polyethylene Outer Conductor Overlapping Copper Foil
Jacket Black PE or Low Smoke Halogen-free Fire-retardant
Jacket Color Black
MECHANICAL SPECIFICATIONS
Single Bending radius 400 mm Multiple bending radius 800 mm Minimum Distance to Wall 50 mm Tensile Strength 2500 N Bending Moment 15.5N.m Flat Plate Crush Strength 1000kg/m Recommended Hanger Spacing 0.8~1.2m Fire Retardancy Test Method IEC 60332-1 | IEC 60332-3C-24 Smoke Index Test Method IEC 61034 Toxicity Index Test Method IEC 60754-1 & | IEC 60754-1
ENVIRONMENTAL SPECIFICATION STANDARD CONDITION
Storage Temperature -55 ℃ ~ +85 ℃ Installation Temperature -40 ℃ ~ +80 ℃ Operating Temperature -55 ℃ ~ +85 ℃ Relative Humidity 95% ROHS YES
As with any radiating cable, the performance in building or tunnel environments may deviate from figures based on free space method Due to the cable design, single lengths should not be less than 80m (262ft)
Attenuation Test Method IEC 61196-4 Attenuation Tolerance ±10% Attenuation ,Ambient Temperature 20℃ | 68℉ Coupling Loss Test Method IEC 61196-4 Coupling Loss Tolerance ±5dB
Coupling loss values are given with a tolerance of ±5 dB and longitudinal loss values with a tolerance of ±5%.
Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.
See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com
RADIATING COAXIAL CABLE
Leaky Cable
ELECTRICAL SPECIFICATIONS
Capacitance
75.0 pF/m Impedance
50±2 Ω
Velocity
89% Insulation Resistance
>5000 MΩ•km
Jacket Spark
8 KV Insulation Voltage
10 KV
Inner Conductor DC Resistance
1.00 Ω/km Outer Conductor DC Resistance
2.40 Ω/km
Stop Band
1012~1052MHz & 2025~2110MHz Operating Frequency Band
75~2700 MHz
Optimum Operating Frequency Band
700~2700 MHz VSWR
800~960 MHz
≤1.30 1700~2025 MHz
≤1.30
2110~2170 MHz
≤1.30 2300~2700 MHz
≤1.30
ELECTRICAL PERFORMANCE
Frequency Attenuation Coupling Loss (2m) MHz dB/100 m dB/100 ft 50%(dB) 95%(dB)
75 001 0,24 70 78 100 001 000 69 79 150 001 0,34 80 90 350 002 0,55 84 94 450 002 0,61 83 94 700 003 0,82 75 79 800 003 0,88 70 73 900 003 0,94 69 72
1800 005 1,62 66 69 1900 006 1,77 66 68 2200 006 1,95 65 68 2400 007 2,19 63 66 2600 008 2,41 64 67 2700 009 2,62 63 66
Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.
See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com
RADIATING COAXIAL CABLE
Leaky Cable
Radiating cables facilitate radio communication where the usual free space propagation of electromagnetic waves is hampered, undesired or impossible- in tunnels, mines, buildings, alongside tracks or lines and in large complexes like exhibition grounds or airports. Our Radiating series focus on some Specific band which can provide an optimized performance. They are popularly used in GSM/CDMA/UMTS system.
RLK114R10(Z)(R)
Coaxial Radiating Cable, Broadband from 75 –960 MHz, 1-1/4” in, Low smoke, black non-halogenated or fire retardant polyolefin jacket. Type HLCTY(Z)(R)-50-32(1-1/4"D)
PHYSICAL DIMENSIONS CONSTRUCTION MATERIALS
Nominal Size 1-1/4" Inner Conductor Diameter 13.00 mm | 0.5118" Dielectric Diameter 32.80 mm | 1.2913" Outer Conductor Diameter 33.20 mm | 1.3071" Diameter Over Jacket 37.80 mm | 1.5039"
Inner Conductor Smooth Copper Tube Dielectric Physical Foam Polyethylene Outer Conductor Overlapping Copper Foil
Jacket Black PE or Low Smoke Halogen-free Fire-retardant
Jacket Color Black
MECHANICAL SPECIFICATIONS
Single Bending radius 400 mm Multiple bending radius 800 mm Minimum Distance to Wall 50 mm Tensile Strength 2500 N Bending Moment 15.5N.m Flat Plate Crush Strength 1000kg/m Recommended Hanger Spacing 0.8~1.2m Fire Retardancy Test Method IEC 60332-1 | IEC 60332-3C-24 Smoke Index Test Method IEC 61034 Toxicity Index Test Method IEC 60754-1 & | IEC 60754-1
ENVIRONMENTAL SPECIFICATION STANDARD CONDITION
Storage Temperature -55 ℃ ~ +85 ℃ Installation Temperature -40 ℃ ~ +80 ℃ Operating Temperature -55 ℃ ~ +85 ℃ Relative Humidity 95% ROHS YES
As with any radiating cable, the performance in building or tunnel environments may deviate from figures based on free space method Due to the cable design, single lengths should not be less than 80m (262ft)
Attenuation Test Method IEC 61196-4 Attenuation Tolerance ±10% Attenuation ,Ambient Temperature 20℃ | 68℉ Coupling Loss Test Method IEC 61196-4 Coupling Loss Tolerance ±5dB
Coupling loss values are given with a tolerance of ±5 dB and longitudinal loss values with a tolerance of ±5%.
Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.
See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com
RADIATING COAXIAL CABLE
Leaky Cable
ELECTRICAL SPECIFICATIONS
Capacitance
75.0 pF/m Impedance
50±2 Ω
Velocity
89% Insulation Resistance
>5000 MΩ•km
Jacket Spark
10 KV Insulation Voltage
10 KV
Inner Conductor DC Resistance
1.00 Ω/km Outer Conductor DC Resistance
2.40 Ω/km
Stop Band
180~280MHz & 500~580MHz Operating Frequency Band
75~1000 MHz
VSWR 75~150 MHz
≤1.30 300~500 MHz
≤1.30
600~750 MHz
≤1.30 806~960 MHz
≤1.30
ELECTRICAL PERFORMANCE
Frequency Attenuation Coupling Loss (2m) MHz dB/100 m dB/100 ft 50%(dB) 95%(dB)
75 001 0,24 63 73 100 001 000 64 74 150 001 0,37 65 76 350 002 0,58 64 68 450 002 0,64 67 72 650 003 0,82 65 69 800 003 0,94 59 61 900 003 1,04 58 60 960 004 1,19 58 62
Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.
See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com
RADIATING COAXIAL CABLE
Leaky Cable
Radiating cables facilitate radio communication where the usual free space propagation of electromagnetic waves is hampered, undesired or impossible- in tunnels, mines, buildings, alongside tracks or lines and in large complexes like exhibition grounds or airports. Our coupling series can support all major services from 75 MHz to 3 GHz and is therefore optimally suited for multi-operator and multi-band applications.
RCF114C24(Z)
Coaxial Radiating Cable, Broadband from 75 –2400 MHz, 1-1/4 in, Low smoke, black non-halogenated or fire retardant polyolefin jacket. Type HLCTY(Z)-50-32(1-1/4")
PHYSICAL DIMENSIONS CONSTRUCTION MATERIALS
Nominal Size 7/8" Inner Conductor Diameter 13.00 mm | Dielectric Diameter 32.50 mm | Outer Conductor Diameter 35.80 mm | Diameter Over Jacket 38.60 mm |
Inner Conductor Smooth Copper Tube Dielectric Physical Foam Polyethylene Outer Conductor Overlapping Copper Foil Jacket Black PE or Low Smoke Halogen-free Fire-retardant Jacket Color Black
MECHANICAL SPECIFICATIONS
Single Bending radius 150mm Multiple bending radius 700 mm Minimum Distance to Wall 50 mm Tensile Strength 2900 N Bending Moment 15.5N.m Flat Plate Crush Strength 1000kg/m Recommended Hanger Spacing 0.8~1.2m Fire Retardancy Test Method IEC 60332-1 | IEC 60332-3C-24 Smoke Index Test Method IEC 61034 Toxicity Index Test Method IEC 60754-1 & | IEC 60754-1
ENVIRONMENTAL SPECIFICATION STANDARD CONDITION
Storage Temperature -55 ℃ ~ +85 ℃ Installation Temperature -40 ℃ ~ +80 ℃ Operating Temperature -55 ℃ ~ +85 ℃ Relative Humidity 95% ROHS YES
As with any radiating cable, the performance in building or tunnel environments may deviate from figures based on free space method Due to the cable design, single lengths should not be less than 80m (262ft)
Attenuation Test Method IEC 61196-4 Attenuation Tolerance ±10% Attenuation ,Ambient Temperature 20℃ | 68℉ Coupling Loss Test Method IEC 61196-4 Coupling Loss Tolerance ±5dB
Coupling loss values are given with a tolerance of ±5 dB and longitudinal loss values with a tolerance of ±5%.
Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.
See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com
RADIATING COAXIAL CABLE
Leaky Cable
ELECTRICAL SPECIFICATIONS
Capacitance
76.0 pF/m Impedance
50±2 Ω
Velocity
88% Insulation Resistance
>5000 MΩ•km
Jacket Spark
10 KV Insulation Voltage
10 KV
Inner Conductor DC Resistance
1 Ω/km Outer Conductor DC Resistance
1 Ω/km
Stop Band
- Operating Frequency Band
75~2400 MHz
VSWR 0.3~0.5 GHz
≤1.30 0.8~1.0 GHz
≤1.30
1.7~2.7GHz
≤1.30
ELECTRICAL PERFORMANCE
Frequency Attenuation COUPLING LOSS(2m) MHz dB/100 m dB/100 ft 50%(dB) 95%(dB)
75 0,8 0,24 61 71
150 1,1 0,34 64 74
450 2,5 0,76 75 85
800 3,3 1,01 76 86
900 3,5 1,07 76 86
1800 5 1,52 77 87
2200 5,9 1,8 77 87
2400 6,5 1,98 78 88 Maximum attenuation value shall be 105% of the nominal attenuation value
Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.
See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com
RADIATING COAXIAL CABLE
Leaky Cable
Radiating cables facilitate radio communication where the usual free space propagation of electromagnetic waves is hampered, undesired or impossible- in tunnels, mines, buildings, alongside tracks or lines and in large complexes like exhibition grounds or airports. Our Radiating series focus on some Specific band which can provide an optimized performance. They are popularly used in GSM/CDMA/UMTS system.
RCF158R27(Z)(R)
Coaxial Radiating Cable, Broadband from 75 –2700 MHz, 1-5/8” in, Low smoke, black non-halogenated or fire retardant polyolefin jacket. Type HLHTY(Z)(R)-50-42(1-5/8"C1)
PHYSICAL DIMENSIONS CONSTRUCTION MATERIALS
Nominal Size 1-5/8" Inner Conductor Diameter 17.40 mm | 0.6850" Dielectric Diameter 42.80 mm | 1.6850" Outer Conductor Diameter 43.50 mm | 1.7126" Diameter Over Jacket 48.00 mm | 1.8898"
Inner Conductor Helical Copper Tube Dielectric Physical Foam Polyethylene Outer Conductor Overlapping Copper Foil
Jacket Black PE or Low Smoke Halogen-free Fire-retardant
Jacket Color Black
MECHANICAL SPECIFICATIONS
Single Bending radius 510 mm Multiple bending radius 900 mm Minimum Distance to Wall 50 mm Tensile Strength 3000 N Bending Moment 16.0N.m Flat Plate Crush Strength 1500kg/m Recommended Hanger Spacing 0.8~1.2m Fire Retardancy Test Method IEC 60332-1 | IEC 60332-3C-24 Smoke Index Test Method IEC 61034 Toxicity Index Test Method IEC 60754-1 & | IEC 60754-1
ENVIRONMENTAL SPECIFICATION STANDARD CONDITION
Storage Temperature -55 ℃ ~ +85 ℃ Installation Temperature -40 ℃ ~ +80 ℃ Operating Temperature -55 ℃ ~ +85 ℃ Relative Humidity 95% ROHS YES
As with any radiating cable, the performance in building or tunnel environments may deviate from figures based on free space method Due to the cable design, single lengths should not be less than 80m (262ft)
Attenuation Test Method IEC 61196-4 Attenuation Tolerance ±10% Attenuation ,Ambient Temperature 20℃ | 68℉ Coupling Loss Test Method IEC 61196-4 Coupling Loss Tolerance ±5dB
Coupling loss values are given with a tolerance of ±5 dB and longitudinal loss values with a tolerance of ±5%.
Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.
See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com
RADIATING COAXIAL CABLE
Leaky Cable
ELECTRICAL SPECIFICATIONS
Capacitance
75.0 pF/m Impedance
50±2 Ω
Velocity
89% Insulation Resistance
>5000 MΩ•km
Jacket Spark
10 KV Insulation Voltage
15 KV
Inner Conductor DC Resistance
1.50 Ω/km Outer Conductor DC Resistance
1.50 Ω/km
Stop Band
1012~1052MHz & 2025~2110MHz Operating Frequency Band
75~2700 MHz
Optimum Operating Frequency Band
700~2700 MHz VSWR
75~150 MHz
≤1.30 800~960 MHz
≤1.30
1700~2025 MHz
≤1.30 2110~2170 MHz
≤1.30
2300~2700 MHz
≤1.30
ELECTRICAL PERFORMANCE
Frequency Attenuation Coupling Loss (2m) MHz dB/100 m dB/100 ft 50%(dB) 95%(dB)
75 001 0,18 70 79 100 001 0,24 70 81 150 001 0,27 78 90 350 001 000 83 93 450 002 0,46 83 94 700 002 0,58 74 77 800 002 0,64 70 72 900 002 001 69 71
1800 004 1,19 64 68 1900 004 1,28 63 66 2000 004 1,34 63 66 2200 005 1,46 63 65 2400 005 1,62 62 64 2600 006 1,83 63 65 2700 007 002 63 66
Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.
See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com
RADIATING COAXIAL CABLE
Leaky Cable
Radiating cables facilitate radio communication where the usual free space propagation of electromagnetic waves is hampered, undesired or impossible- in tunnels, mines, buildings, alongside tracks or lines and in large complexes like exhibition grounds or airports. Our Radiating series focus on some Specific band which can provide an optimized performance. They are popularly used in GSM/CDMA/UMTS system.
RCF158R25(Z)(R)
Coaxial Radiating Cable, Broadband from 75 –2500 MHz, 1-5/8” in, Low smoke, black non-halogenated or fire retardant polyolefin jacket. Type HLHTY(Z)(R)-50-42(1-5/8"C2)
PHYSICAL DIMENSIONS CONSTRUCTION MATERIALS
Nominal Size 1-5/8" Inner Conductor Diameter 17.40 mm | 0.6850" Dielectric Diameter 42.80 mm | 1.6850" Outer Conductor Diameter 43.50 mm | 1.7126" Diameter Over Jacket 48.00 mm | 1.8898"
Inner Conductor Helical Copper Tube Dielectric Physical Foam Polyethylene Outer Conductor Overlapping Copper Foil
Jacket Black PE or Low Smoke Halogen-free Fire-retardant
Jacket Color Black
MECHANICAL SPECIFICATIONS
Single Bending radius 510 mm Multiple bending radius 900 mm Minimum Distance to Wall 50 mm Tensile Strength 3000 N Bending Moment 16.0N.m Flat Plate Crush Strength 1500kg/m Recommended Hanger Spacing 0.8~1.2m Fire Retardancy Test Method IEC 60332-1 | IEC 60332-3C-24 Smoke Index Test Method IEC 61034 Toxicity Index Test Method IEC 60754-1 & | IEC 60754-1
ENVIRONMENTAL SPECIFICATION STANDARD CONDITION
Storage Temperature -55 ℃ ~ +85 ℃ Installation Temperature -40 ℃ ~ +80 ℃ Operating Temperature -55 ℃ ~ +85 ℃ Relative Humidity 95% ROHS YES
As with any radiating cable, the performance in building or tunnel environments may deviate from figures based on free space method Due to the cable design, single lengths should not be less than 80m (262ft)
Attenuation Test Method IEC 61196-4 Attenuation Tolerance ±10% Attenuation ,Ambient Temperature 20℃ | 68℉ Coupling Loss Test Method IEC 61196-4 Coupling Loss Tolerance ±5dB
Coupling loss values are given with a tolerance of ±5 dB and longitudinal loss values with a tolerance of ±5%.
Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.
See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com
RADIATING COAXIAL CABLE
Leaky Cable
ELECTRICAL SPECIFICATIONS
Capacitance
75.0 pF/m Impedance
50±2 Ω
Velocity
89% Insulation Resistance
>5000 MΩ•km
Jacket Spark
10 KV Insulation Voltage
15 KV
Inner Conductor DC Resistance
1.50 Ω/km Outer Conductor DC Resistance
1.50 Ω/km
Stop Band
1012~1052MHz & 2025~2110MHz Operating Frequency Band
75~2500 MHz
Optimum Operating Frequency Band
700~2500 MHz VSWR
800~960 MHz
≤1.30
1700~2025 MHz
≤1.30 2110~2170 MHz
≤1.30
2300~2700 MHz
≤1.30
ELECTRICAL PERFORMANCE
Frequency Attenuation Coupling Loss (2m) MHz dB/100 m dB/100 ft 50%(dB) 95%(dB)
75 001 0,18 70 79 100 001 0,24 70 81 150 001 0,27 78 90 350 001 000 83 93 450 002 0,46 83 94 700 002 0,58 74 77 800 002 0,64 67 68 900 002 001 66 68
1800 004 1,22 62 65 1900 004 1,31 63 65 2000 005 001 61 63 2100 005 1,46 59 62 2200 005 1,62 59 62 2400 006 1,89 57 61 2500 007 002 57 62
Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.
See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com
RADIATING COAXIAL CABLE
Leaky Cable
Radiating cables facilitate radio communication where the usual free space propagation of electromagnetic waves is hampered, undesired or impossible- in tunnels, mines, buildings, alongside tracks or lines and in large complexes like exhibition grounds or airports. Our Radiating series focus on some Specific band which can provide an optimized performance. They are popularly used in GSM/CDMA/UMTS system.
RLK158R10(Z)(R)
Coaxial Radiating Cable, Broadband from 75 –960 MHz, 1-5/8” in, Low smoke, black non-halogenated or fire retardant polyolefin jacket. Type HLHTY(Z)(R)-50-42(1-5/8"D)
PHYSICAL DIMENSIONS CONSTRUCTION MATERIALS
Nominal Size 1-5/8" Inner Conductor Diameter 17.40 mm | 0.6850" Dielectric Diameter 42.80 mm | 1.6850" Outer Conductor Diameter 43.50 mm | 1.7126" Diameter Over Jacket 48.00 mm | 1.8898"
Inner Conductor Helical Copper Tube Dielectric Physical Foam Polyethylene Outer Conductor Overlapping Copper Foil
Jacket Black PE or Low Smoke Halogen-free Fire-retardant
Jacket Color Black
MECHANICAL SPECIFICATIONS
Single Bending radius 510 mm Multiple bending radius 900 mm Minimum Distance to Wall 50 mm Tensile Strength 3000 N Bending Moment 16.0N.m Flat Plate Crush Strength 1500kg/m Recommended Hanger Spacing 0.8~1.2m Fire Retardancy Test Method IEC 60332-1 | IEC 60332-3C-24 Smoke Index Test Method IEC 61034 Toxicity Index Test Method IEC 60754-1 & | IEC 60754-1
ENVIRONMENTAL SPECIFICATION STANDARD CONDITION
Storage Temperature -55 ℃ ~ +85 ℃ Installation Temperature -40 ℃ ~ +80 ℃ Operating Temperature -55 ℃ ~ +85 ℃ Relative Humidity 95% ROHS YES
As with any radiating cable, the performance in building or tunnel environments may deviate from figures based on free space method Due to the cable design, single lengths should not be less than 80m (262ft)
Attenuation Test Method IEC 61196-4 Attenuation Tolerance ±10% Attenuation ,Ambient Temperature 20℃ | 68℉ Coupling Loss Test Method IEC 61196-4 Coupling Loss Tolerance ±5dB
Coupling loss values are given with a tolerance of ±5 dB and longitudinal loss values with a tolerance of ±5%.
Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.
See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com
RADIATING COAXIAL CABLE
Leaky Cable
ELECTRICAL SPECIFICATIONS
Capacitance
75.0 pF/m Impedance
50±2 Ω
Velocity
89% Insulation Resistance
>50000 MΩ•km
Jacket Spark
10 KV Insulation Voltage
15 KV
Inner Conductor DC Resistance
1.50 Ω/km Outer Conductor DC Resistance
1.50 Ω/km
Stop Band
180~280MHz & 500~580MHz
Operating Frequency Band
75~1000 MHz VSWR
75~150 MHz
≤1.30 300~500 MHz
≤1.30
600~750 MHz
≤1.30 806~960 MHz
≤1.30
ELECTRICAL PERFORMANCE
Frequency Attenuation Coupling Loss (2m) MHz dB/100 m dB/100 ft 50%(dB) 95%(dB)
75 001 0,18 63 73 100 0,85 0,26 64 73 150 001 0,27 67 77 350 001 0,43 67 70 450 002 0,49 67 71 650 002 0,61 63 67 800 002 0,73 58 61 900 003 0,79 58 60 960 003 0,88 59 61
Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.
See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com
RADIATING COAXIAL CABLE
Leaky Cable
Radiating cables facilitate radio communication where the usual free space propagation of electromagnetic waves is hampered, undesired or impossible- in tunnels, mines, buildings, alongside tracks or lines and in large complexes like exhibition grounds or airports. Our coupling series can support all major services from 75 MHz to 3 GHz and is therefore optimally suited for multi-operator and multi-band applications.
RCF158C24(Z)
Coaxial Radiating Cable, Broadband from 75 –2400 MHz, 1-5/8 in, Low smoke, black non-halogenated or fire retardant polyolefin jacket. Type HLHTY(Z)-50-42(1-5/8")
PHYSICAL DIMENSIONS CONSTRUCTION MATERIALS
Nominal Size 7/8" Inner Conductor Diameter 17.40 mm | Dielectric Diameter 42.80 mm | Outer Conductor Diameter 46.50 mm | Diameter Over Jacket 49.50 mm |
Inner Conductor Helical Copper Tube Dielectric Physical Foam Polyethylene Outer Conductor Overlapping Copper Foil Jacket Black PE or Low Smoke Halogen-free Fire-retardant Jacket Color Black
MECHANICAL SPECIFICATIONS
Single Bending radius 510mm Multiple bending radius 900 mm Minimum Distance to Wall 50 mm Tensile Strength 3300 N Bending Moment 16 N.m Flat Plate Crush Strength 1200kg/m Recommended Hanger Spacing 0.8~1.2m Fire Retardancy Test Method IEC 60332-1 | IEC 60332-3C-24 Smoke Index Test Method IEC 61034 Toxicity Index Test Method IEC 60754-1 & | IEC 60754-1
ENVIRONMENTAL SPECIFICATION STANDARD CONDITION
Storage Temperature -55 ℃ ~ +85 ℃ Installation Temperature -40 ℃ ~ +80 ℃ Operating Temperature -55 ℃ ~ +85 ℃ Relative Humidity 95% ROHS YES
As with any radiating cable, the performance in building or tunnel environments may deviate from figures based on free space method Due to the cable design, single lengths should not be less than 80m (262ft)
Attenuation Test Method IEC 61196-4 Attenuation Tolerance ±10% Attenuation ,Ambient Temperature 20℃ | 68℉ Coupling Loss Test Method IEC 61196-4 Coupling Loss Tolerance ±5dB
Coupling loss values are given with a tolerance of ±5 dB and longitudinal loss values with a tolerance of ±5%.
Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.
See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com
RADIATING COAXIAL CABLE
Leaky Cable
ELECTRICAL SPECIFICATIONS
Capacitance
76.0 pF/m Impedance
50±2 Ω
Velocity
88% Insulation Resistance
>5000 MΩ•km
Jacket Spark
10 KV Insulation Voltage
15 KV
Inner Conductor DC Resistance
1.50 Ω/km Outer Conductor DC Resistance
0.80 Ω/km
Stop Band
- Operating Frequency Band
75~2400 MHz
VSWR 0.3~0.5 GHz
≤1.30 0.8~1.0 GHz
≤1.30
1.7~2.7GHz
≤1.30
ELECTRICAL PERFORMANCE
Frequency Attenuation COUPLING LOSS(2m) MHz dB/100 m dB/100 ft 50%(dB) 95%(dB)
75 0,6 0,18 68 78
150 0,8 0,24 71 81
450 1,9 0,58 75 85
800 2,6 0,79 75 85
900 2,7 0,82 75 84
1800 4,4 1,34 77 86
2200 5,1 1,55 77 86
2400 5,5 1,68 77 86 Maximum attenuation value shall be 105% of the nominal attenuation value
Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.
See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com
RADIATING COAXIAL CABLE
Radiating Connectors
Radiating cables facilitate radio communication where the usual free space propagation of electromagnetic waves is hampered, undesired or impossible- in tunnels, mines, buildings, alongside tracks or lines and in large complexes like exhibition grounds or airports. The connectors are designed according the standard inter-faces N and 7/16 Type. Contact components are silver platedto minimize insertion loss, mechanical parts are nickel platedfor heavy-duty handling and best corrosion resistance.
Radiating Connectors N – 7/16
FEATURES and BENEFITS
• High contact force and Cu-Be inner contacts • Silver plated • Watertight (IP67) • Corrosion resistant • Quick trimming • Installation "fit on and tighten it"
MECHANICAL SPECIFICATIONS
CONNECTORS CHARACTERISTICS AND TARGET
structure Characteristics N Type Din 7/16 Type
Impedance Operating Voltage Frequency Range Shielding Effectiveness Inner Contact Resistance Outer Contact Resistance Intermodulation Insulation Resistance Dielectric Withstanding Voltage Insertion Loss VSWR 0.8 ~ 1.0GHz 1.7 ~ 2.5GHz Inner Conductor Pin Inner Conductor Socket Insulator Body & Outer Conductor Gasket Temperature Range Durability
50 Ω 1500 V
≤18.0 GHz ≥115 dB ≤0.8 mΩ
≤0.25 mΩ ≤-155 dBc ≥5000 MΩ
2500 V ≤0.1 dB ≤1.08 ≤1.10
Brass/Silver Plating Tin Bronze /Silver Plating PTFE or TPX Brass/Trimetal plating Silicon Rubber
-65 ºC ~ +165ºC ≥500 cycle
50 Ω 2700 V
≤7.5 GHz ≥115 dB ≤0.4 mΩ ≤0.2 mΩ
≤-155 dBc ≥10000 MΩ
3000 V ≤0.08 dB
≤1.08 ≤1.10
Brass/Silver Plating Tin Bronze/Silver Plating PTFE or TPX Brass/Trimetal Plating Silicon Rubber
-65 ºC ~ +165 ºC ≥500 cycle
Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.
See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com
RADIATING COAXIAL CABLE
Leaky Cable
TABLE CONNECTORS SELECTION GUIDE
NF-7/8”L NM-1/2”H DINF-1/2”L DINM-1/2”H
Leaky Radiating CABLE Cable type leaky 1/2”R leaky 7/8”R leaky 1-1/4”R leaky 1-5/8”R
Connector code
DINM-1/2”R DINM-7/8”R DINM-1-1/4”R DINM-1-5/8”R
DINF-1/2”R DINF-7/8”R DINF-1-1/4”R DINF-1-5/8”R
NM-1/2”R NM-7/8”R NM-1-1/4”R NM-1-5/8”R
NF-1/2”R NF-7/8”R NF-1-1/4”R NF-1-5/8”R
Model Ref. Description
DINM-1/2”R CCF12RDM Connector Radiating DINM-1/2”R std Trimetal plating Straight Male
DINF-1/2”R CCF12RDF Connector Radiating DINF-1/2”R std Trimetal plating Straight Male
NM-1/2”R CCF12RNM Connector Radiating NM-1/2”R std Trimetal plating Straight Male
NF-1/2”R CCF12RNF Connector Radiating NF-1/2”R std Trimetal plating Straight Male
DINM-7/8”R CCF78RDM Connector Radiating DINM-7/8”R std Trimetal plating Straight Male
DINF-7/8”R CCF78RDF Connector Radiating DINF-7/8”Rstd Trimetal plating Straight Male
NM-7/8”R CCF78RNM Connector Radiating NM-7/8”R std Trimetal plating Straight Male
NF-7/8”R CCF78RNF Connector Radiating NF-7/8”R std Trimetal plating Straight Male
DINM-1-1/4”R CCF114RDM Connector Radiating DINM-1-1/4”R std Trimetal plating Straight Male
DINF-1-1/4”R CCF114RDF Connector Radiating DINF-1-1/4”R std Trimetal plating Straight Male
NM-1-1/4”R CCF114RNM Connector Radiating NM-1-1/4”R std Trimetal plating Straight Male
NF-1-1/4”R CCF114RNF Connector Radiating NF-1-1/4”R std Trimetal plating Straight Male
DINM-1-5/8”R CCF158RDM Connector Radiating DINM-1-5/8”R std Trimetal plating Straight Male
DINF-1-5/8”R CCF158RDF Connector Radiating DINF-1-5/8”R std Trimetal plating Straight Male
NM-1-5/8”R CCF158RNM Connector Radiating NM-1-5/8”R std Trimetal plating Straight Male
NF-1-5/8”R CCF158RNF Connector Radiating NF-1-5/8”R std Trimetal plating Straight Male
DIATING COAXIAL CABLE
Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.
See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com
RADIATING COAXIAL CABLE
Radiating Clamp – Premium
Radiating Clamps plastic and metalic systems System Premium for 1/2", 5/8”, 7/8”, 1-1/4” and 1-5/8”
FEATURES and BENEFITS
• SLX cable clamps are used for the installation of radiating cables in tunnels.
• SLX clamps may be installed with or without spacers. • SLX cable clamps are designed with two clips coupled to a
central snap-in cap. • The two clips allow a quick insertion of the cable, while
the central snap-in cap assures the final locking. • An additional locking screw is joint.
TECHNICAL FEATURES SPECIFICATIONS
Plastic System Premium
Are used to fasten radiating cables in tunnels, underground and indoor in general. Additional AISI 302 security screw
PA6V0, black colour, self extinguishing, halogen free (according to UL94 - V0).
Operating temperature : - 40°C + 125°C
Single-hand installation – a matter of course with CLIC, place the cable, apply slight pressure and the clamp locks itself with a sharp clic.
• Automatic locking by pushing cable into clamp • Unlocks with screwdriver
Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.
See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com
RADIATING COAXIAL CABLE
Radiating Clamp – Premium
TECHNICAL FEATURES SPECIFICATIONS
Metalic System Premium
SLXM - Square Collar for Radiating Cables
Complete with rigid calibrated saddles The SLXM square collar is formed by two shells joined by M6 screws and calibrated saddles. It is recommended in combination with SLXMM clamps for radiating cables.
Whether inserted at a suitable distance (10-15 m) among SLX clamps, it prevents radiating cable lines from falling down, in case of fire.
Material:
Collar: AISI 304 stainless steel Saddles: Glass reinf. P.A., black colour
SLXCM - Around Collar for Radiating Cables
The SLXCM round collar has been especially designed for quick installation of HF and DC cables as well as for pipes.
It is recommended in combination with SLX clamps for radiating cables. Whether inserted at a suitable distance (10-15 m) among SLX clamps, it prevents radiating cable lines from falling down, in case of fire.
Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.
See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com
RADIATING COAXIAL CABLE
Radiating Clamp – Premium
TABLE SELECTION GUIDE
Base Plastic Spacer
P.A. Fiberglass Spacer P.A./fiberglass spacer to keep SLXR cable clamps separated from the wall. Fixing with P.A. plug R8/SP. Material: PA6V0, self-extinguishing, halogen free (according to UL94 - V0).
Code H Description pack gr
SLX2050
50 base spacer 50 mm 50 14
SLX2080 80 base spacer 80 mm 50 22
Plastic System
Code Model Cables For cables øD L H h1 gr
SLX0012 SLXR 1/2’’ 15-18 46 36,5 13 20
SLX0058 SLXR 5/8” 20-23 46 41 13 22
SLX0078 SLXR 7/8” 26-30 46 45 13 26
SLX0114 SLXR 1.1/4” 38-41 66 65 17 68
SLX0158 SLXR 1.5/8” 47-51 81,5 80 19 116
Metalic System
Code Article/description ØD L H pz gr
SLX0012M Clamp Metalic System Premium 1/2’’ 16 - 17 16 - 17 22 36 50 90
SLX0058M Clamp Metalic System Premium 5/8” 21 - 23 21 - 23 22 36 50 86
SLX0078M Clamp Metalic System Premium 7/8” 27 - 28 27 - 28 34 48 50 114
SLX0114M Clamp Metalic System Premium 1.1/4” 39 - 40 39 - 40 34 48 50 110
SLX0158M Clamp Metalic System Premium 1.5/8” 50 - 52 50 - 52 34 48 50 108
Code Article Cables ØD H pz
SLXCM0020 Clamp Metalic System Premium 1/2’’ Ø 13 ÷ 20 1/2” Ø 13 ÷ 20 44 20
SLXCM0030 Clamp Metalic System Premium 7/8” Ø 22 ÷ 30 7/8” Ø 22 ÷ 30 55 20
SLXCM0040 Clamp Metalic System Premium 1.1/4” Ø 30 ÷ 40 1.1/4” Ø 30 ÷ 40 67 20
SLXCM0050 Clamp Metalic System Premium 1.5/8” Ø 40 ÷ 52 1.5/8” Ø 40 ÷ 52 79 20
Code L Description pack
SLX1050 50 Spacers with M8x16 screw and washer RPI 8/16 50
SLX1075
75 Spacers with M8x16 screw and washer RPI 8/16 50
SLX1010 100 Spacers with M8x16 screw and washer RPI 8/16 50
Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.
See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com
RADIATING COAXIAL CABLE
Radiating Clamp – Premium
EXAMPLES OF INSTALLATION
Base Plastic Spacer
SLX Installation example Installation of Radiating Cable in Tunnel Installation by using SLX cable clamps. SLX cable clamps are fixed to the wall by a mechanical or chemical fastener, directly or through spacers The installation is quick and safe thanks to an elastic provisional pre-fixing of the cable. The final closure is assured by the cap of the SLX cable clamp
SLX Installation example Installation of Radiating Cable on Cable Trail Fixing of SLX clamp on linear guide rails with spacers SLX10 or SLX24
Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.
See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com
RADIATING COAXIAL CABLE
Radiating Clamp – Standard
Radiating Clamp System Clic clamps are used for installing radiating cables in gal- leries and tunnels with or without spacers. The installation is very simple and quick. Stainless Stell Cable Clamps are used to provide Fire Resistant installations of Radiating Cables in galleries or tunnels with or without spacers. The installation is very simple and quick. To limit the interference that could be caused by Metal Objects on the RF field generated by a Radiating Cable, only every 10th fixing should be metallic.
Radiating Clamps plastic and metalic systems 1/2" | 5/8” | 7/8” | 1-1/4” | 1-5/8”
FEATURES and BENEFITS
• Lock with 1 or 2 locking positions • Automatic locking by pushing cable into clamp, reusable • Unlocks with screwdriver • Pivoted hangers allow installation down to -25°C • Slot design allows installation correction of up to 4.5 mm • Slot for insertion of flange for rod and stud mounting
TECHNICAL FEATURES SPECIFICATIONS
Plastic System
Material Pure Polyamide, halogen free, fire class UL94HB, UV-resistant
Environmental
Operating Temperature °C - 25 to +110
Installation Temperature °C -10 to +60
Color standard black
Metalic System
Material Metalic Clamp Fire Resistant
Environmental
Operating Temperature °C - 50 to +400
Color standard black and metalic
Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.
See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com
RADIATING COAXIAL CABLE
Radiating Clamp – Standard
TABLE SELECTION GUIDE
Plastic System
Clic type for 1/2” for 5/8” for 7/8” for 1-1/4” for 1-5/8”
Clamping mm 14.3 - 16.8 19.5 - 22.0 24.6 - 27.8 35.5 - 39.5 46.5 - 50.5
Max. load N 600 700 850 1100 1300
Part reference SLX9415AN SLX9420AN SLX9426AN SLX9435AN SLX946AN
Metalic System
Clic type for 1/2” for 5/8” for 7/8” for 1-1/4” for 1-5/8”
Clamping mm 15 22 27 38 49
Max. load N 600 700 850 1100 1300
Part reference SLX9XCLIP15 SLX9XCLIP22 SLX9XCLIP27 SLX9XCLIP35 SLX9XCLIP46
SPACERS and ACCESSORIES
Click Calmp
Reference Description
SLX94CSCRM Round base spacer 80 mm
SLX94CSCQM Round base spacer 80 mm
SLX9X481207981 Wood screw 4.8 x 120mm
SLX9X895912 DIN 912 M8x95mm, hex socket head
SLX96FX Nylon plug for wood screw diameter 6 mm
SLX9X8SFA Stainless steel plug M8
Silex Global Spain, S.L. | All specifications are subject to change. [email protected] - www.silexst.com Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. © 2015 Silexst Todos los derechos reservados It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements.
See www.silexst.com for the most current information. Revised: September 09, 2014. www.silexst.com
RADIATING COAXIAL CABLE
Leaky Cable
Regulatory Compliance/Certifications
ISO 9001:2008 ISO 14001:2004 OHSAS 18001
RoHS 2011/65/EU RoHS Compliant Designed, manufactured and/or distributed under quality management system
Silexstr Radiating Cable ® functions as a distributed antenna to provide communications in tunnels, mines and large building complexes and is the solution for any application in confined areas. Slots in the copper outer conductor allow a controlled portion of the internal RF energy to be radiated into the surrounding environment. Coupling & Radiating Cable is used for both one-way and two-way communication systems and because of its broadband capability, a single radiating cable can handle multiple communication systems simultaneously.
Radiating and Coupling Cable Systems Frequency TETRA / TETRAPOL TDMA / CDMA 800 GSM 900 DCS / GSM 1800 PCN / PCS 1900 UMTS 2200 W-CDMA 2200 DECT 900 GSM-R WLAN 2400 WLAN 5700 LTE
Cables Together the cables and the connectors from Silex are an unbeatable match that optimises the entire system performance:
• Low attenuation • Excellent field strength with low coupling loss • Increased amplifier spacing due to very low longitudinal attenuation • Simple connector installation • Quick cable installation • Halogen-free and fire retardant jacketing
.
Silex Global Spain, S.L. San Erasmo, 31 Nave 8 28021 - Madrid (Spain) Tel.: + 34 915 05 67 76 E-Mail: [email protected] Web: www.silexst.com Web: www.silexfiber.com Certified Products: ISO / EN / IEC Ordering No. Info32543SLink/WERE/09-2014 pA 1SFSD34 © 09.2015 Silexst Production & Powered By Silex Global Spain
All specifications are subject to change. See www.silexst.com for the most current information. Revised: September 06, 2015
Silex Global Spain, S.L. | The information contained in this document is accurate to the best of our knowledge and representative of the part described herein. It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements. Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal.
[email protected] – www.silexst.com ©2014 Silexst All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of Silexst