catalogue uv medium pressure lamps...the product portfolio includes signal lamps for streets,...

28
UV Medium Pressure Lamps Catalogue Flash me m a d e i n F r a n c e

Upload: others

Post on 24-Sep-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Catalogue UV Medium Pressure Lamps...The product portfolio includes signal lamps for streets, railways, air and wa-terways; special lamps for medicine and research; household lamps

UV Medium Pressure Lamps

Italy s.r.l.

Europe S.A.S

Lichttechnik GmbH

Leuchten GmbH

Catalogue

Flash me

made in

F ra nce

Page 2: Catalogue UV Medium Pressure Lamps...The product portfolio includes signal lamps for streets, railways, air and wa-terways; special lamps for medicine and research; household lamps

EMEA

AMERICAS

ASIA & PACIFIC REGION

Germany, Austria, Switzerland & Eastern Europe

Sales Manager Tel. +49(0)64329131-33Fax +49(0)[email protected]

Others EMEA countries

Sales Manager

Tel. +33(0)383803060Fax +33(0)[email protected]

Order Desk

Tel. +49(0)64329131-80Fax +49(0)[email protected]

Order Desk

Tel. +33(0)383803060Fax +33(0)[email protected]

Sales Manager

Tel. +33(0)383803021Fax +33(0)[email protected]

Order Desk

Tel. +33(0)383803060Fax +33(0)[email protected]

Sales Manager

Tel. +827086661637Fax [email protected]

Order Desk

Tel. +33(0)383803060Fax +33(0)[email protected]

Printingdate:October2014

Printed with matte and glossy UV coating dried with DR. FISChER’s lamps.

Alltechnicaldata,dimensionsandillustrationsarenon-binding.Wereservetherighttomakealterationsinconstruction.Weassumenoliabilityforprintingerrors.ThegeneralsalesconditionsofDR.FISCHEREuropeS.A.S.apply.

Photos:©Technigraf(p.12)-©H&SAutoshot(p.15)-Fotolia(p.1/9/12/15/19)-DR.FISCHER

Design:FiguresImposées,www.figimp.com

DR. FISChER Europe S.A.S. Zone industrielle de Montrichard BP 80149 54705 Pont-à-Mousson CEDEXFRANCE

Tel. +33(0)383803060Fax +33(0)383803048

Internet:www.dr-fischer-group.com

2 Contacts

Page 3: Catalogue UV Medium Pressure Lamps...The product portfolio includes signal lamps for streets, railways, air and wa-terways; special lamps for medicine and research; household lamps

Content 3

Introduction

Contacts ................................................................................................................................................................................................................................................................................................ 2DR. FISCHER Group .............................................................................................................................................................................................................................................................. 4DR. FISCHER Europe S.A.S ......................................................................................................................................................................................................................................... 5 Location ................................................................................................................................................................................................................................................................................................. 6Information about ultraviolet ................................................................................................................................................................................................................................... 7

HPA lamps 9

HPM lamps 12

HP lamps 15

XOP lamps 19

UV lamps, cross-reference table 22

Technical support 23

Overview of bases and terminals .................................................................................................................................................................................................................... 24

Customer request form ............................................................................................................................................................................................................................................... 25

DR. FISCHER & You: an efficient partnership for improving your performance .............................................................................. 26

Symbols & recommendations ............................................................................................................................................................................................................................. 26

Page 4: Catalogue UV Medium Pressure Lamps...The product portfolio includes signal lamps for streets, railways, air and wa-terways; special lamps for medicine and research; household lamps

The DR. FISCHER Group - Competence, Innovation, Service TheDR.FISCHERGroup isoneof the in-ternationalleadingprovidersoflampsandlights.ThevariouscompaniesoftheGroupcomplement each other with their indivi-dual specializations and together form acompetent, innovativeand fairpartner forcustomersworldwide.Thegroupemploysmorethan550peopleinEurope.

TheDR.FISCHERGroupstarted20 yearsago as the result of the merge of threefamilycompanies :DR.FISCHERSpezial-lampenfabrik GmbH, Kegler Lichttech-nik GmbH and Kandem Leuchten GmbH.Each individual company, with their spe-cific fields, is a perfect complement totheothers.Thismakesitpossibletofulfillcustomer’swishesandrequirementspre-cisely, quickly and in a solution-orientedway.Thegreateststrengthsofthegroupis

inofferingtailor-madespecialapplicationsandspecificallroundsolutions.

The product portfolio includes signallamps for streets, railways, air and wa-terways; special lamps for medicine andresearch;household lamps forovens,ex-tractorhoodsandrefrigerators;ultraviolet(UV)mediumpressure lampsforprinting,drying; infrared halogen lamps and solu-tionsforheatingandwarming;LEDbasedlightingsolutions.

More information:www.dr-fischer-group.com

4 DR. FISChER Group

DR. FISCHER Italy s.r.l., in Alpignano, pro-duces special lamps for the domestic field.

Pont-à-Mousson (France) is the headquar-ters of DR. FISCHER Europe S.A.S., the R&D and production center of infrared ha-logen, UV medium pressure and high-vol-tage lamps.

The headquarter of the complete DR. FISCHER Group is located in Diez, Ger-many. This is the main production center for Kandem Luminaires, LED Solutions and low-voltage lamps.

We are certified for quality and environmental management.

Page 5: Catalogue UV Medium Pressure Lamps...The product portfolio includes signal lamps for streets, railways, air and wa-terways; special lamps for medicine and research; household lamps

DR. FISChER Europe S.A.S. 5

The Pont-à-Mousson factory: a wealth of experience in lamps’ productionThe manufacturing of lamps started in1886 in Pagny-sur-Moselle, France withFabiusHenrionlaunchingthefirstproduc-tionofincandescentlamps.

In1981,PhilipsbuiltanewfactoryinPont-à-Mousson (10 km away) which became“PhilipsEclairage”in1985.

In1989, theassemblyof infraredhalogenlampsbeganinPont-à-Moussoninanewdedicated area. From this time, PhilipsEclairage started developing innovativeproducts like the internationally famousHeLeNTMrange.

In 2010, the DR. FISCHER Group, tookover the complete site of Philips Pont-à-Mousson.Bythisacquisition,thecompanystrengthened its halogen production withhigh-speedmachines.ItnowoffersoneofthebiggestinfraredandUVportfolioswithmarketing/salesanddistributionservices.Thismeansthatthebiggestcenterofcom-

petenceandproductionforinfraredandUVlamps and solutions is located in France,betweenMetzandNancy.

DR. FISCHER Group also integrated inPont-à-Moussonallcompetencesforspe-cialUVsolutions–fromresearchoverde-velopment,qualityandproductiontomar-ketingandsales.Thisuniquesynergyofthelatesttechnolo-gy,experiencedandmotivatedemployees,triedandtrustedprocedures,flexibilityandmanyyearsofexperienceincreatingspe-cificsolutionstogetherwiththecustomermakeustheidealpartnerinseekingfutureapplicationsandsolutions.UV lamps are used for copying with UVsensitive materials, curing lacquers/paint/ink,curingglue/resin,diazocopying,polymerizationofpolyester,printedcircuitboardsexposure,platemaking(offsetprin-ting),copyboardlighting/copying,materialdurability testing. Innovative UV applica-

tions will become increasingly importantin many industrial processes: polymercuring, photosensitive materials exposureandmanyothers.Ourexperienceandknow-howmeansthatwe can be competent, thinking partnersforourcustomersinthedevelopmentandrealizationofsuchinnovativeUVsolutions.

More information:www.dr-fischer-group.com

Our values:• Stronglysupportingourcustomerswith customizedandinnovativesolutionsor systems

• Providinghighqualityproductsmadein France

Our commitment• Fulfillingourcustomerswiththebest solutions

• Offeringareliableafter-salesservicemade in

F ra nce

The ISO certificates show the quality.

Page 6: Catalogue UV Medium Pressure Lamps...The product portfolio includes signal lamps for streets, railways, air and wa-terways; special lamps for medicine and research; household lamps

6 DR. FISChER Europe S.A.S.

Location

Pont-à-MoussonislocatedintheEastofFrance.Findusefulhintsforcomingby:

Road:

•A31Highway: Luxembourg-Metz-Nancy-LyonTrain: •RoissyCharlesdeGaulleTGV(High-speed

train)-LorraineTGV(1:20)•ParisEST-Metz(1:40)

Airports: •Metz-Nancy-LorraineRegionalAirport

(20min)•LuxembourgandSaarbrückenInternational

Airports(1:20)•RoissyCharlesdeGaulle(CDG)Airport/

OrlyAirport(3:00)•FrankfurtAirport(2:45)

Visit us:

Alpignano

Diez

Pont-à-Mousson

Amsterdam (500 km)Brussels (300 km)

Luxemburg(100 km)

Berlin (810 km)Frankfurt (275 km)Saarbrucken (95 km)London

(620 km) Reims

(180 km) A31

Paris(320 km)

A4 A4 Strasbourg(190 km) Metz

(30 km)

DR. FISCHER Europe S.A.S. Pont-à-Mousson

TGV station Metz-Nancy-Lorraine Airport (20 km)A

31

Paris (300 km)

A31

Lyon (420 km)

Marseilles(725 km)

RN4

Madrid(1,600 km)

Barcelona(1,050 km)

Geneva(475 km)

Nancy(30 km)

Roma(1,170 km)

Page 7: Catalogue UV Medium Pressure Lamps...The product portfolio includes signal lamps for streets, railways, air and wa-terways; special lamps for medicine and research; household lamps

DR. FISCHER ultraviolet solutions

Information about ultraviolet 7

Ultraviolet solutions are used for appli-cationsinprint,paint,glueandcuringin-dustriesaswellasinmaterialtestingandin the entertainment field. DR. FISCHERoffersawide rangeof standardproductsandisabletoextendtherangetomeetourcustomers requirements. Lamp spectraaretunedbychangingthelampchemistry

to meet specific application needs. Alllampsarelongarcdischargelamps.

Fundamentals:UV lamps rely on the technology ofmediumpressuredischargelamps.TheyaremainlylocatedintotheUV-Arange.However,theymayemitUV-BandUV-Cwhichrequireprecautionsinuse.

In operation, the UV medium-pressureemitters emit rather wide spectra,approximatelymadeof:

•28%ofUVradiation(UV-C14%, UV-B7%,UV-A7%),•21%ofvisiblelight,•34%ofinfraredradiation,•17%areconsumedbythepower supplyandheat.

The mercury content of the lampis responsible for the generation ofemission lines thatpeakatwavelengthclose to the absorption peaks of thephoto-initiators’usedininks,varnishesorUVpowders.

TobroadenortunethespectrumofUVradiation,inadditiontomercury,wecanintroduceavarietyofmetalsaltssuchasgallium,ironorcobalt.

invisible light visible light invisible light

ULTRAVIOLETULTRAVIOLET

VISIBLELIGHT

VISIBLELIGHT

INFRARED

INFRARED

ThepowerofanUV lamp isexpressed inW/cm(electricalpowerinW/arclengthincm)andisdeterminedby:• electricalpower• quartztube• UVradiationspectrum

Typical powers densities are 80, 100 and

120W/cm.ThemediumpressureUVlampsareprimarilyusedinpolymerizationequip-ment of inks, varnishes and UV powders.Somemanufacturersalsousethemfordi-sinfectionofappliances.

In addition to standard products, we ma-nufacturealargenumberofspeciallamps

designed for our partners’ specific appli-cations.Everyday,weworkwithourcus-tomerstofindtogetherthebestsolutionsfortheirneeds.

Medium-pressure UV lamps

Page 8: Catalogue UV Medium Pressure Lamps...The product portfolio includes signal lamps for streets, railways, air and wa-terways; special lamps for medicine and research; household lamps

8 Information about ultraviolet

Benefits & Advantages of DR. FISCHER ultraviolet lamps: DR. FISCHER UV Medium Pressure lamps combine a highUV radiation and a long lifetime. For our standard UV lamps(100W/cm),weguaranteea lifetimeof1,500operatinghourswith less than 25% UV radiation decrease. However, DR.FISCHERUVemittersfrequentlyachievemorethan4,000hours

oflife.Itisstronglyinfluencedbytheiroperatingconditionsandtheirapplications.

AllourUV lampsaredeveloped forahighefficiencyandverystablearc.

TheHPAandHPMproductrangesarebasedonmercurylampswithadditives.Thesearetypicallymetalsthatwillhelptotunethelampspectrumexactlytowhatisneededtocureinksoractivatecompounds.

XOPproductsarefilledwithpureXenongas.Thisinertgashastheadvantageofsendingoutabroadspectrumthatisveryclosetosunlight.XOPareinstantlightandhotrestrike.

Overview of applications:Applications Lamp types

HP HPM/HPA XOP

CopyingwithUVsensitivematerials • •

Dryinglacquers/paint/ink • •

Curingadhesives(glue,resin) • •

Diazocopying •

Photopolymerisation •

Printedcircuitbroadexposure •

Oxidationoforganicpollutants •

Surfacedisinfection • •

Plate-making(offsetprinting) • •

Copyboardlighting/copying •

Stroboscope/entertainment •

Materialtesting • •

•Pinch Seal

>Morecompactlamp

>Cheaperprocess

Sealing technologyOurcustomersneedhermeticstructureadaptedtotheirapplications.DR.FISCHERlampscanbemanufacturedwithoneoftwotypesofseal:

•Shrink Seal

>Flexibleshrinklength

>Asymmetricallamppossible

Page 9: Catalogue UV Medium Pressure Lamps...The product portfolio includes signal lamps for streets, railways, air and wa-terways; special lamps for medicine and research; household lamps

HPA lamps

hPA lamps 9

Page 10: Catalogue UV Medium Pressure Lamps...The product portfolio includes signal lamps for streets, railways, air and wa-terways; special lamps for medicine and research; household lamps

Offset Print HPA UV-A: Medium-pressure metal halide lampsDR. FISCHER HPA lamps, optimized forthe UV-A bandwith (315 to 400 nm), areideal for reprography and photochemicalprocesses. Their high radiant efficiencyandhigharc-stabilityensurecost-efficientandreliableusage.Theyprovidetheideal

optimal light source for contact copyingof images from transparent film to UV-sensitivecarrierssuchasfilm,offsetplates,printed circuit boards and microfilms.These DR. FISCHER HPA lamps are alsoperfectly suitable for photochemical

process applications such as theUV-curingofglues,resinsandpigmentedlacquers.

Applications Integration in systems

n Reprography photochemical processes • Plate-making, • UV-curing of glues, resins, pigmented lacquers, • Printed circuits.

n Copying of images • Film, • Offset plates, • Microfilms.

n Measures must be taken to protect eyes and skin from UV-B and UV-C light which are emitted by the lamps.

n Bulb temperature should be kept between 750 and 950°C, with maximum 350°C at the pinches. This might require forced air cooling adapted to power level.

n DR. FISCHER HPA lamps are made of ozone-free quartz and are constructed to generate an optimum UV-A spectrum.

UV

Introduction

Features Benefits

Spectrum is optimized for UV-A radiation Best match with UV-A photo sensitizers

No ozone production Best environmental choice

Characteristics of HPA lamps:

HPA Typical Spectrum of an iron doped lamp

Emis

sion

(arb

itrar

yun

it)

200 250 300 350 400 450 500

90

80

70

60

50

40

30

20

10

0

Wavelength(nm)

10 hPA lamps

Page 11: Catalogue UV Medium Pressure Lamps...The product portfolio includes signal lamps for streets, railways, air and wa-terways; special lamps for medicine and research; household lamps

hPA lamps 11

Products

HPA products

X

T TD

XCB

12NC Type # WattW

VoltV

Lamp Current

A

UV-A (*) irrad. at 0h

µW/cm2

Arc length

mm

(B)

Total length

mm

(C)

Bulb diame-

ter mm(D)

Base Cables+/-5 mm

(X)

Terminal

(T)

Qty Box pc

9280 756 06002 HPA 1000/20R 1,100 120 10.5 1,780 21 129 30 10 100/100 straight faston 4

9280 805 06054 HPA 1200 1,200 125 10.5 2,240 83 147 30 8 195/195 stripped end 4

9280 810 06002 HPA 1001R 1,150 130 10.0 2,000 26 137 25 10 110/110 straight faston 4

9280 563 06002 HPA 2020S 2,000 240 8.7 515 83 185 28 10 350/350 stripped end 4

(*) UV irradiation measured perpendicular to lamp axis at 1 m distance with a relative spectral sensitivity according to IEC. UV-A is the wavelength range between 315-400 nm.

12NC Type # Retrofit lamp WattW

VoltV

Lamp

Current A

Arc length

mm

(B)

Total Length

mm

(C)

Bulb diameter

mm

(D)

Base Cables+/-5 mm

(X)

Terminal

(T)

UV-1211-00 HPA 130/120-S Natgraph - NG 1300 Fe 15,500 1,700 10 1,338 1,486 23 19 100/100 eyelet 5 mm

UV-1211-10 HPA 110/120-S Natgraph - NG 1100 Fe 14,000 1,550 10 1,170 1,321 23 19 100/100 eyelet 5 mm

UV-1211 HPA 90/120-S Natgraph - NG 900 Fe 11,000 1,270 10 960 1,095 23 19 100/100 eyelet 5 mm

Shrink Seal

base 8 base 10 base 19

Pinch Seal

Page 12: Catalogue UV Medium Pressure Lamps...The product portfolio includes signal lamps for streets, railways, air and wa-terways; special lamps for medicine and research; household lamps

HPM lamps

12 hPM lamps

©Te

chni

graf

Page 13: Catalogue UV Medium Pressure Lamps...The product portfolio includes signal lamps for streets, railways, air and wa-terways; special lamps for medicine and research; household lamps

Applications Integration in systems

n Printing and plotting applications

n Copying of images from transparent film to UV-sensitive carriers such as film, offset plates, printed circuit board and microfilms

n UV curing of glues, resins and pigmented lacquers

n Measures must be taken to protect eyes and skin from UV-B and UV-C light which are emitted by the lamps.

n Bulb temperature should be kept between 750 and 950°C, with maximum 350°C at the pinches. This might require forced air cooling adapted to power level.

n DR. FISCHER HPM lamps are made of ozone-free quartz

HPM Lamps: Medium-pressure metal halide lampsDR. FISCHER HPM Diazo lamps emitin the Diazo range (230 – 450 nm) andare optimized for UV-A radiation. Beingsimilar to HPA lamps, HPM lamps aredesigned to meet the special spectraldemands of reprography, photochemicalapplications and the use of Diazo colors.

Thelampspectrumhasbeenmodifiedbyaddingadditivesandadjustingthemercurycontenttogenerateexactlythosespectrallines needed to cure Diazo colors. Theyaretherefore idealforhigh-quality, large-format printing and plotting applicationsin the architectural and engineering

industries. In addition, HPM Diazo lampsprovide a high radiant efficiency and higharc stability for cost-efficient and reliableusage.

Introduction

UV

Features Benefits

Spectrum is optimized for UV-A radiation Best environmental choice

No ozone production Ideal for high quality, large-format printing and plotting applications

HPM Repro lamps radiate in the Diazo range Cost-efficient

Most lamps are designed to run at several power levels, e.g. standby, medium and full Reliable usage

Burning position horizontal (+/- 10°) High radiant efficiency

High arc-stability

Characteristics of HPM lamps:

70

60

50

40

30

20

10

0

HPM Typical Spectrum of a gallium doped lamp

Emis

sion

(arb

itrar

yun

it)

Wavelength(nm)

200 250 300 350 400 450 500

hPM lamps 13

Page 14: Catalogue UV Medium Pressure Lamps...The product portfolio includes signal lamps for streets, railways, air and wa-terways; special lamps for medicine and research; household lamps

X

T TD

XCB

HPM products

Products

(*) UV irradiation measured perpendicular to lamp axis at 1 m distance with a relative spectral sensitivity according to IEC. Diazo is the wavelength range between 320-440 nm.

12NC Type # WattW

VoltV

Lamp Cur-rent

A

Diazo (*) irrad. at

0h µW/cm2

Arc length

mm

(B)

Total length

mm

(C)

Bulb diame-

ter mm(D)

Base Cables+/-5 mm

(X)

Terminal

(T)

Qty Box pc

9280 723 05102 HPM 15 1,950 245 9.0 4,100 131 203 33 8 295/295 stripped end 4

9280 724 05138 HPM 16 2,000 245 8.7 4,600 113 220 30 X-CLIP - - 4

9280 727 05102 HPM 17 2,000 243 8.7 4,600 113 175 30 8 320/320 stripped end 4

9280 728 05102 HPM 15 1,950 245 9.0 4,100 131 203 33 8 320/320 stripped end 4

9280 729 05102 HPM 12 460 120 4.1 800 44 98 22 8 315/315 stripped end 4

9280 744 05102 HPM 13 1,000 125 8.6 2,000 83 147 30 8 145/145 stripped end 4

9280 792 06002 HPM 25/C 5,000 245 23.0 12,000 186 276 30 12 190/190 stripped end 4

9280 794 06002 HPM 4010 (HPM30) 4,000 310 13.5 10,500 117 204 33 11 190/190 stripped end 4

9280 807 06002 HPM 4020 4,000 400 11.5 11,500 162 249 30 11 120/120 straight faston 4

9280 813 06002 HPM 3000 3,350 400 9.0 9,000 105 191 30 11 125/125 straight faston 4

Pinch Seal

Shrink Seal 12NC Type # Retrofit lamp Watt

WVolt

VLamp

Cur-rent

A

Arc length

mm

(B)

Total Length

mm

(C)

Bulb diame-

ter mm(D)

Base Cables+/-5 mm

(X)

Terminal

(T)

UV-1214-20 HPM 140/120-S Bayer -KB1841 1400 Ga 16,800 1,520 12.8 1,400 1,535 22.0 18 300/300 eyelet 5mm

UV-1221-10 HPM 142/100-S UV-Technik - UVH-14222 G-1 14,200 1,900 8.3 1,420 1,575 22.5 19 600/2280 stripped end

base 8 base 11 base 12 Xclip basebase 19base 18

14 hPM lamps

Page 15: Catalogue UV Medium Pressure Lamps...The product portfolio includes signal lamps for streets, railways, air and wa-terways; special lamps for medicine and research; household lamps

HP lamps

hP lamps 15

©H

&S

Auto

shot

Page 16: Catalogue UV Medium Pressure Lamps...The product portfolio includes signal lamps for streets, railways, air and wa-terways; special lamps for medicine and research; household lamps

16 hP lamps

Introduction

Applications Integration in systems

n Advanced oxidation of organic pollutants

n UV curing of adhesives, glues, resins

n Drying of pigmented lacquers, inks

n Measures must be taken to protect eyes and skin from UV-B and UV-C light which are emitted by the lamps.

n Bulb temperature should be kept between 750 and 950°C, with maximum 350°C at the pinches. This might require forced air cooling adapted to power level.

n HP lamps, made of high-quality quartz, are generating ozone. A ventilation system might be necessary to eva- cuate the ozone produced by the lamp.

HP Lamps: Medium-pressure mercury lampsLamps are primarily used in polymeriza-tion equipment of inks, varnishes and UVpowders. Some manufacturers also usethemfordisinfectingappliances.HP lamps are available in a wide rangewithanarclengthbetween4and140cen-timeters. HP /80 and /120 can be loadedup to 80 and 120 W per cm of arc length

respectively.Thelampscanbefittedwithvarioustypesofendfittingsfromourcata-logue or equipped with customer specificfittings,cablesorpins.

Medium pressure mercury lamps containsophisticated quantities of mercury bro-mides, providing a self-cleaning halogen

cycle,toensureaconstantUVoutputoverlamplife.

UV

Features Benefits

Short waves UV radiation with a peak at 253.7 nm High arc stability

Ozone producing Ideal for high quality printing application

Burning position horizontal (+/- 10°) High system efficacy

Characteristics of HP lamps:

600

500

400

300

200

100

0

HP Typical Spectrum of a mercury lamp

Emis

sion

(arb

itrar

yun

it)

Wavelength(nm) 200 250 300 350 400 450 500

Page 17: Catalogue UV Medium Pressure Lamps...The product portfolio includes signal lamps for streets, railways, air and wa-terways; special lamps for medicine and research; household lamps

hP lamps 17

Products

X

T TD

XCB

HP products

12NC Type # WattW

VoltV

Lamp Current

A

Power density µW/cm

UV-C (*)

irrad. at 0hµW/cm2

Arc length

mm

(B)

Total length

mm

(C)

Bulb diame-

ter mm(D)

Base Cables+/-5 mm

(X)

Terminal

(T)

Bur-ning pos.

Qty Box pc

9285 500 05156 HP 20/120 2,000 230 9.0 120 2,500 200 331 22.0 19 175/175 stripped end Horiz. 4

9285 569 05154 HP 70/60 4,000 1,400 3.0 60 3,700 700 765 14.5 8 95/95 stripped end Horiz. 4

9285 864 05128 HP 4/120 400 125 3.5 120 410 31 105 14.0 R7s - - Any 10

9285 865 05128 HP 4/120 SE 400 125 3.5 120 410 31 111 14.0 GY9.5 - - Any 10

9285 875 05154 HP 70/30 2,000 1,400 1.6 30 1,600 700 765 14.5 8 95/95 stripped end Horiz. 4

9285 882 05156 HP 20/100 2,100 245 9.6 100 2,500 195 255 22.0 8 240/240 stripped end Horiz. 4

9285 883 05154 HP 35/120 2,850 490 6.0 120 3,600 343 380 22.0 1 235/235 stripped end Horiz. 4

9285 884 05154 HP 50/120 4,100 670 7.2 120 5,700 502 532 22.0 1 235/235 stripped end Horiz. 4

9285 886 05154 HP 65/80 5,000 840 6.6 80 6,700 645 669 22.0 2 235/235 stripped end Horiz. 4

9285 888 05154 HP 140/80 11,000 1,850 6.5 80 14,800 1,415 1,439 22.0 2 235/235 stripped end Horiz. 4

9285 892 05154 HP 65/120 5,000 840 6.6 120 6,700 637 669 22.0 1 235/235 stripped end Horiz. 4

9285 893 05154 HP 80/120 6,400 1,030 7.0 120 8,600 800 832 22.0 1 240/240 stripped end Horiz. 4

9285 896 05154 HP 105/120 8,300 1,350 6.7 120 11,000 1,057 1,089 22.0 1 230/230 stripped end Horiz. 4

9285 898 05154 HP 140/120 11,000 1,850 6.5 120 14,800 1,407 1,439 22.0 1 235/235 stripped end Horiz. 4

(*) UV irradiation measured perpendicular to lamp axis at 1 m distance with a relative spectral sensitivity according to IEC. UV-C is the wavelength range between 200-280 nm.

Pinch Seal

R7s base GY9.5 basebase 1 base 8base 2 base 19

Page 18: Catalogue UV Medium Pressure Lamps...The product portfolio includes signal lamps for streets, railways, air and wa-terways; special lamps for medicine and research; household lamps

18 hP lamps

Shrink Seal12NC Type # Retrofit lamp Watt

WVolt

VLamp

Cur-rent

A

Power den-sity

W/cm

Arc length

mm

(B)

Total Length

mm

(C)

Bulb diame-

ter mm(D)

Base Cables+/-5 mm

(X)

Terminal

(T)

UV-1214-00 HP 140/120-S Bayer - KB1959 1400 Hg 16,800 1,520 12.80 120 1,400 1,535 22.0 18 300/300 eyelet 5 mm

UV-1221-00 HP 142/100-S UV-Technik - UVH-14222-1 14,200 1,900 8.30 100 1,420 1,575 22.5 19 600/2280 stripped end

UV-1221-20 HP 120/130-S UV-Technik - UVH-12022-3 15,400 1,900 9.00 130 1,200 1,353 22.5 19 600/2030 stripped end

UV-1221-30 HP 107/100-S UV-Technik - UVH-10722-0 10,800 1,500 8.00 100 1,070 1,223 22.5 19 600/1920 stripped end

UV-1221-40 HP 65/80-S UV-Technik - UVH-6522-0 5,400 840 7.00 80 650 803 22.5 19 600/1500 stripped end

UV-1226-20 HP 105/180-S IST - T-1050 -K2H 18,500 1,850 10.00 180 1,050 1,160 26.0 23 500/2000 eyelet 5 mm

UV-1307-01 HP 55/160-S IST - T-550 -NA-3H 9,000 1,100 9.00 160 550 665 25.0 21 NA NA

UV-1307-11 HP 105/160-S IST - T-1050 -NA-2H 20,000 2,070 9.60 160 1,050 1,165 25.0 21 NA NA

UV-1307-21 HP 108/200-S IST - T-1080 -NA-2H 22,000 2,250 9.50 200 1,080 1,195 25.0 21 NA NA

UV-1310 HP 105/110-S Ushio - UVH-1055-105-03-1 11,700 1,530 8.50 110 1,055 1,150 22.0 19 150/150 straight faston

UV-1311-01 HP 30/140-S F820489 4,000 360 9.00 140 300 380 18.0 22 150/150 splice

UV-1315-00 HP 75/160-S Honle - 075-24-160-TB1 7,000 850 8.40 160 750 850 26.0 22 500/500 eyelet 5 mm

UV-1315-10 HP 78/160-S Honle - 078-24-160-TB1 7,200 860 8.40 160 780 880 26.0 22 500/500 eyelet 5 mm

UV-1324-20 HP 40/80-S Alpha Cure -AC-0690 3,000 252 11.00 80 400 530 21.0 18 220/360 eyelet 5 mm

UV-1324-30 HP 35/100-S Alpha Cure -AC-1605 3,000 455 6.66 100 355 470 23.0 19 140/750 stripped end

UV-1324-00 HP 15/160-S Alpha Cure - AC-4431 2,000 160 11.00 120 155 275 21.0 19 520/520 straight faston

UV-1329-02 HP 108/160-S KBA - KBA 105 11,000 1,600 10.00 160 1,080 1,190 25.0 25 NA N

base 25base 22 base 23base 18 base 21base 19

Page 19: Catalogue UV Medium Pressure Lamps...The product portfolio includes signal lamps for streets, railways, air and wa-terways; special lamps for medicine and research; household lamps

XOP lamps

XOP lamps 19

Page 20: Catalogue UV Medium Pressure Lamps...The product portfolio includes signal lamps for streets, railways, air and wa-terways; special lamps for medicine and research; household lamps

Introduction

Applications Integration in systems

n WeatheringXenonlampsarefrequentlyusedinsunsimulationapplications.DuetotheiralmostcontinuousspectrumfromUVtoIR,theyareanidealsourcetosimulatetheeffectsofsunexposuretoadhesives,colors(fading)andmaterialslikeplastics(fading,gettingbrittleandporous,etc.)

Theyarethebestsourceintestingthedegradationofproductsexposedtothesun-lightastheyreproducedaylightspectrumverywell.

n Copyboard lightingSmall,horizontalcopyboardsaswellaslargeverticalonescanbelitveryfrequently.OwingtotheirspectralpowerdistributionXOPlampsareeminentlysuitableforcolorreproduction,whileforblack-and-whitereproductiontheselampsaresuperiortoeveryotherlightsource.

n Stop-and-repeat copying machinesXOPlampsareextremelyusefulforthisapplicationasnorun-uptimeisnecessary

n Strobe lighting•Danceandnightclubs:Provideanillusionofslowmotioneffects•Emergencyvehiclesandsituations•Alarmsystems•Theatrelighting•Runninglights•Specialoccasion:Hauntedhouse,outdoorHalloweendisplay

n Shielding must be provided to pro- tect eyes and skin from short waves UV light output.

n Lampholder and wiring must be insulated from the luminaire be- cause of the high starting voltage

n Bulb temperature should be kept between 750 and 950°C, with maxi- mum 350°C at the pinches. This might require forced air cooling adapted to power level.

n DR. FISCHER XOP lamps are made of ozone-free quartz

XOP xenon lampsXOPxenonlampsarelinearlampsequip-ped with a special cable connection thatprevents arcing. Our standard portfolio oflinear XOP lamps is using a 12 mm maxdiameter quartz tube and is available ina range from 240 up to 540 mm overalllength, depending on the wattage. Thespectrumradiationislikethatofallxenonlamps, almost continuous, ranging from

about200to1000nm.Thecolortempera-tureis5600K.XOPxenonlampsareusedeitherincontinuousorpulsedmode(stro-boscopy).Pulsed xenon lamps are operated usinga semi-resonant type of driver circuit. Inaddition,theyneedanelectronicignitertoprovide the starting pulse of some 10 kV.Theyfeatureinstantignitionandre-ignition

and require no warm-up time. The ave-rageratedliferangesbetween250and500hours at a depreciation of 20% after 250burninghours.DR. FISCHER XOP xenon lamps are alsoavailablewithatriggerwire.

UV

Features Benefits

Xenon filling Good color performance, reproducing very well sunlight

Hot Restrike No standby mode needed

Very small diameter Ideally suited for reflector design

Instant start Energy saving

Instant light High arc-stability

Universal burning position Creative freedom

Characteristics of XOP lamps:

XOP Typical Spectrum of a xenon lamp0.4

0.35

0.3

0.25

0.2

0.15

0.1

0.05

0

Emis

sion

(arb

itrar

yun

it)

Wavelength(nm) 380 430 480 530 580 630 680 730 780

20 XOP lamps

Page 21: Catalogue UV Medium Pressure Lamps...The product portfolio includes signal lamps for streets, railways, air and wa-terways; special lamps for medicine and research; household lamps

XOP lamps 21

Products

12NC Type # Watt

W

Volt

V

Lamp Current

A

Arc length

mm

(B)

Total (2) length

mm

(C)

Bulb diame-

ter mm(D)

Base Cables+/-5 mm

(X)

Terminal

(T)

Burning pos.

Qty Box pc

9283 768 05102 XOP 7 OF 650 54 12.3 158 241 12 5 115/115 stripped end Any 4

9283 769 05102 XOP 15 OF 1,000 100 10.7 312 395 12 5 115/115 stripped end Any 6

9283 775 05102 XOP 25 OF 1,100 207 10.5 457 540 12 5 115/115 stripped end Any 5

Standard lamps

Lamps with a trigger wire

12NC Type # Watt

W

Volt

V

Lamp Current

A

Arc length

mm

(B)

Total (2) length

mm

(C)

Bulb diame-

ter mm(D)

Base Cables +/-5 mm

(X)

Terminal

(T)

Burning pos.

Qty Box pc

9283 001 05156 XOP 15 A 1,000 100 10.7 312 395 12 5 115/115 stripped end Any 6

9283 002 05155 XOP 25 A 1,100 207 10.5 457 540 12 5 115/115 stripped end Any 5

9283 003 05154 XOP 7 A 650 54 12.3 158 241 12 5 115/115 stripped end Any 4

(2) For a definition of Overall Length (OAL), see drawing of lamp base dimensions.

X T TD X

CB

base 5

XOP products

Page 22: Catalogue UV Medium Pressure Lamps...The product portfolio includes signal lamps for streets, railways, air and wa-terways; special lamps for medicine and research; household lamps

Cross-reference table12NC DR. FISCHER Ushio Heraeus Amba Theimer Sylvania Kuhnast Philips Other

928072305102 HPM15 MHL15 Q2127Z11 AM571X TH2160 M038 JGMHO2030-0 HPM15 Beltron28054

928072405138 HPM16 TH5090 M105 JGMHO5090-0 HPM16 BeltronMH5000E

928072705102 HPM17 MHL17 Q2123Z11 AM572X TH2510 M036 JGMHO2200-0 HPM17 Beltron28052

928072805102 HPM15 MHL15 Q2127Z11 AM571X TH2160 M038 JGMHO2030-0 HPM15 Beltron28054

928072905102 HPM12 MHL12 Q408Z11 AM580X TH530 M001 JGMH530-0 HPM12

928074405102 HPM13 MHL13 TH2120 M111 JGMHO2120-0 HPM13

928075606002 HPA1000/20R

THO1027A JGMHO1050-7 HPA1000/20R

928078805100 HPA2000R HPA2000R OlecL1261

928079206002 HPM25/C MHL5000 Q5846Z1 AM637X THO5250 M030 JGMHO5031-0 HPM25/C

928079406002 HPM4010(HPM30)

MHL30 TH4080 M022 JGMH4110-0 HPM4010(HPM30)

928080506054 HPA1200 AM622X TH1207 M067 JGMHO1200-7 HPA1200

928080706002 HPM4020 RQ6138Z1KC AM614X TH5020 JGMH5020-0 HPM4020 Primarc45000802Sack200216OZ

928081006002 HPA1001R RQ1148Z4KC AM576X TH1007 M057 JGMH1000-7 HPA1001R Primarc56066110

928081306002 HPM3000 RQ4128Z4KC AM612X TH5007 M025 JGMH5000-7 HPM3000 Primarc56070313Sack200215OZ

928300105156 XOP15A MartinAtomicMAX-15

928300205155 XOP25A

928300305154 XOP7A

928376805102 XOP7OF PXA44 AM633X KX7 X202 XOP7OF

928376905102 XOP15OF PXA45 AM634X KX10 X275 XOP15OF

928377505102 XOP25OF PXA46 AM635X KX22 X102 XOP25OF

928550005156 HP20/120 HOK20/120

928556905154 HP70/60 HTK70/60

928587505154 HP70/30 HTK70/30

928588205156 HP20/100 DQ2022 TQ026510 JGQ027015 HOK20/100 Beltron28029

928588305154 HP35/120 TQ042044 JGQ042044 HOK35/120

928588405154 HP50/120 TQ053041 JGQ059060 HOK50/120

928588605154 HP65/80 TQ072020 JGQ074050 HOK65/80 Beltron28087

928588805154 HP140/80 DQ14022 TQ148012 JGQ150110 HOK140/80 Beltron28032

928589205154 HP65/120 TQ072020 JGQ074051 HOK65/120 Beltron28115

928589305154 HP80/120 TQ088110 JGQ089061 HOK80/120 Beltron28113

928589605154 HP105/120 DQ10522 TQ09085 JGQ113126 HOK105/120

928589805154 HP140/120 DQ14022 TQ148012 JGQ150110 HOK140/120

22 UV lamps

Page 23: Catalogue UV Medium Pressure Lamps...The product portfolio includes signal lamps for streets, railways, air and wa-terways; special lamps for medicine and research; household lamps

Technical support 23

Technical support

Page 24: Catalogue UV Medium Pressure Lamps...The product portfolio includes signal lamps for streets, railways, air and wa-terways; special lamps for medicine and research; household lamps

24 Technical support

Overview of bases

base 8

base 19

R7s base

base 1 base 2 base 5

base 21 base 22 base 23

GY9.5 base

Overview of terminals

Splice

Fork

Faston

Insulated tab

Ring

Special

base 10 base 11

base 12 base 18

Xclip basebase 24 base 25

Page 25: Catalogue UV Medium Pressure Lamps...The product portfolio includes signal lamps for streets, railways, air and wa-terways; special lamps for medicine and research; household lamps

Technical support 25

YouhavetodevelopaUVprojectforyourapplication?GiveusthefollowinginformationandwewillhelpyoutogivethebestUVso-lutiontoyoursystem.

Italy s.r.l.

Europe S.A.S

Lichttechnik GmbH

Leuchten GmbH

Customer request form

CustomerCompany: ...............................................................................................................................................................................Contact person: .....................................................................................................................................................................Function: ................................................................................................................................................................................E-mail adress: .......................................................................................................................................................................

Application:....................................................................................................................................................................................

Used solution currently:..................................................................................................................................................

Lamp description:

1 > Total Length: ........................................................ mm2 > Arc length: ........................................................... mm3 > Bulb Diameter: .................................................... mm 4 > Cable length: ....................................................... mm 5 > Terminal (see p.24) .....................................................

Specific base # (see p.24): ..............................................A > Base length: ........................................................ mmB > Base diameter: .................................................... mm

Lamp Wattage (W): ...........................................................Lamp Voltage (V): .............................................................Lamp current (A): .............................................................Power density (W/cm): .....................................................Lifetime: .................................................................. hours

DR. FISCHER Europe S.A.S.Zone industrielle de Montrichard - BP 8014954700 Pont-à-MoussonTel: +33 (0)3 83 80 30 60 / Fax: +33 (0)3 83 80 30 48

You can download this request form on our website: www.dr-fischer-group.com

Ballast used:❏ electronic❏ magnetic❏ pulsed

Seals:❏ pinch ❏ shrink

Quartz type:❏ ozone free❏ standard

Doping:❏ Hg❏ Fe❏ Ga❏ In❏ Pb❏ Xe

Special characteristics:

If possible, please provide us with a used or new lamp for an appropriate quote and development.

Page 26: Catalogue UV Medium Pressure Lamps...The product portfolio includes signal lamps for streets, railways, air and wa-terways; special lamps for medicine and research; household lamps

DR. FISCHER & You: an efficient partnership for improving your performanceWe, DR. FISCHER, want to be more thanjustasupplierofhigh-qualityUVlamps.Wearecommittedtoofferingyouaworldclassservice in every aspect of our business.One of our key advantages is our innova-tiveResearch&DevelopmentDepartment.We do not only develop lamps or makemeasurements but also improve existingsystems and even offer our demandingcustomerscompletebrandnewsolutions.DR. FISCHER can become your closestpartnerforyourUltravioletapplications.

AtDR.FISCHERweareexperts in impro-vementsofcurrentsystemsandweshowcustomers 3D simulations of systemswhichcaneasily(“Plug&Play”)beinstalledinto their machines for increasing theirperformance.

In fact, on request, we can evaluate theperformanceofourcustomers’systems.• Based on the needs of our demandingcustomers, we are able to provide adviceon specific matters such as a reflectorgeometryoptimization.Theaccuracyofthe

resultsisgivenbytheuseofspecificmea-surementcontrolsystems.•Measurementsareconducted inadarkroomtoeliminateanydisturbances.Lampvoltage, fluxmeter and temperature areunder constant control during measure-ments.

We at DR. FISCHER know, that reducingtimetomarketinthedevelopmentofnewsystems is essential. The specific PH3Doptical modeling software, based on anefficient3Draytracingmethod,isusedtooptimizeourcustomers’high-performanceUVsystemsandsolutions.

Using these tools, our UV modeling sup-portactivitiescanaddresstwomaintopics:•Improvementorupgradingofexistingre-flectorsorsystems• System configuration issues, such aslampspecificationsandarrangement,ins-talledpower,sizingetc.

Our DR. FISCHER UV modeling supportallows our customers to predict system

irradiancebysimulationwithout theneedfor any tooling or prototyping. This en-ablespredictive,quantitativeresults tobeachieved at reasonable cost. The validityofmodelingoutputsisassuredbyregularcalibration.OurUVR&Dteamalwayspro-videsaccuratequotationsforeachprojectyouhave.

Customers working with us will decreasetheir time-to-market, increase their sys-tem’sefficiencyandlifetime.

For more information about our systems and technical support, please contact us!

[email protected]

“Innovation drives our future”

Italy s.r.l.

Europe S.A.S

Lichttechnik GmbH

Leuchten GmbH

26 Technical support

Pictograms description

AB

Preferably do not touch quartz with barehands. If grease or chemical compoundhas been deposited on quartz, simplycleanwithanalcohol-soakedtissuebeforelighting.

Disconnectinstallationfrompowersupplybeforeremovingorinstallingalamp.

Prolonged looking at the lamp duringoperationmayresultindamagetotheeye.

Exposure to UV can result in severedamagetotheskin.

Mercurycontents:recyclingisneeded

UV

RecommendationsWARNINGRisk of electrical shock: turn off power before inspection,installation or removal. Use only in luminaire equipped with asafetycut-outswitch.

Risk of fire:useonlywithcontrolgearand luminairedesignedforthisproduct.RiskofUV/optical/IRradiationwhichmaycauseeye/skin injury(IEC62471Riskgroup3). Ifglassbulb isbrokenturnpoweroffandremovelamp.Useappropriateshieldingoreyeprotection.Donotlookatoperatinglamp.Useonlyinanenclosedluminaire able to contain hot lamp parts, even during testing.Highozone-concentrationsareharmfultohumansandanimals.Assuregoodairventilation.

CAUTIONRisk of burn:Allow lamp tocooldownbeforehandling.Donotuse lamp if glass bulb is scratched or broken. Wear gloveswhen handling broken lamps. Replace lamp quickly at end oflife (markedchange incolor,flickering, failure tostart).Donothandle the bulb with bare hands, otherwise clean with specialtissue.Avoidskincontactwithbrokenlampparts.

INFORMATIONDispose of used lamps according to local regulations.DR.FISCHERcanhandletherecyclingoflampsyousendback.The manufacturer accepts no liability for injury or damageresultingfromincorrectuse.Keepforfuturereference.

Page 27: Catalogue UV Medium Pressure Lamps...The product portfolio includes signal lamps for streets, railways, air and wa-terways; special lamps for medicine and research; household lamps
Page 28: Catalogue UV Medium Pressure Lamps...The product portfolio includes signal lamps for streets, railways, air and wa-terways; special lamps for medicine and research; household lamps

Nikolaus-Otto-Straße65582 Diez / LahnDeutSchLaNDtelefon: +49 (0) 64 32 / 91 31- 0Fax: +49 (0) 64 32 / 6 20 69Internet: www.dr-fischer-group.comemail: [email protected]

Italy s.r.l.

Asia Paci�c Ltd.

Speziallampenfabrik GmbH

Speziallampen Vertriebs GmbH

Europe S.A.S

Lichttechnik GmbH

Leuchten GmbH

Zone industrielle de MontrichardBP 8014954705 Pont-à-Mousson ceDeXFRaNcetél. : +33 (0) 3 83 80 30 60Fax : +33 (0) 3 83 80 30 48Internet: www.dr-fischer-group.comemail : [email protected]

Italy s.r.l.

Asia Paci�c Ltd.

Speziallampenfabrik GmbH

Speziallampen Vertriebs GmbH

Europe S.A.S

Lichttechnik GmbH

Leuchten GmbH

Contacts

Salespartners

www.figimp.co

m