Category 8 Short Channel Performance Demonstration Using Multiple Sourced Prototypes
of Cabling and ICM
B. Moffitt CommScope Systems Engineering
7/4/2015 1 CommScope - 802.3 bq by Submission
Supporters: Victor Renteria Steve Sedio
7/4/2015 2 CommScope - 802.3 bq by Submission
CommScope Prototype Category 8 Short Cabling Link measured two ways
1m cord
3m Cable
1m cord
Mod Jack
Mod Jack
Bel ICM
FoxconnICM
Through ICM from two different manufacturers as PHY chip to PHY chip:
With end plugs removed as measured for TIA compliance:
CommScope Test Head
CommScope Channel
7/4/2015 3 CommScope - 802.3 bq by Submission
Side by side Insertion Loss and Return Loss
Small amount of additional RL
Expected BALUN Loss
Some Additional ILD
Short Channel – Significant RL
Short Channel – Low IL and strong reflections
7/4/2015 4 CommScope - 802.3 bq by Submission
Side by side NEXT and FEXT
Short Channel – Significant Connector NEXT
Manageable Additional FEXT
Manageable Additional NEXT
Conclusions:
• Excellent results in support of ongoing work on 802.3bq and PN-568-C.2-1 demonstrated with critical short channel
• 4 primary cabling performance parameters significantly maintained by the ICM
• Demonstrated compatibility with independent prototype designs from 3 different suppliers
7/4/2015 5 CommScope - 802.3 bq by Submission