ce-632 geotechnical engineering · 2018. 5. 19. · 4 iitgn short course on geotechnical...

47
1 1 Foundation Concepts and Foundation Alternatives Amit Prashant Indian Institute of Technology Gandhinagar Short Course on Geotechnical Investigations for Structural Engineering 15 17 October, 2015 IITGN Short Course on Geotechnical Investigations for Structural Engineering Bearing Capacity 2

Upload: others

Post on 26-Jan-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

  • 1

    1

    Foundation Concepts and Foundation Alternatives

    Amit Prashant Indian Institute of Technology Gandhinagar

    Short Course on

    Geotechnical Investigations for Structural Engineering 15 – 17 October, 2015

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    Bearing Capacity

    2

  • 2

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    3

    Terzaghi’s Bearing Capacity Theory

    Assumption L/B ratio is large plain strain problem Df ≤ B Shear resistance of soil for Df depth is neglected General shear failure Shear strength is governed by Mohr-Coulomb Criterion

    B

    Df neglected Effective overburden

    q = g’.Df

    Strip Footing

    f’ f’ 45−f’/2 45−f’/2

    Shear Planes

    a b

    d e f

    g i

    j k

    qu

    Rough Foundation Surface

    c’- f’ soil B

    I

    II II III III

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    4

    Terzaghi’s Bearing Capacity Theory

    . . 0.5 .u c qq c N q N B Ngg Terzaghi’s bearing

    capacity equation

    Terzaghi’s bearing capacity factors

    Local Shear Failure:

    Modify the strength parameters such as: 2

    3mc c 1

    2tan tan

    3mf f

    Square and circular footing:

    1.3 . . 0.4 .u c qq c N q N B Ngg

    1.3 . . 0.3 .u c qq c N q N B Ngg

    For square

    For circular

  • 3

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    Total and Effective Stress Analysis

    Total stress parameters c and f

    From UC or UU test

    In bearing capacity equation, use total overburden and bulk/saturated density.

    Effective stress parameters c' and f'

    From direct shear test, CU or CD test

    In bearing capacity equation, use effective overburden and bulk/submerged density.

    5

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    6

    Terzaghi’s Bearing Capacity Theory Effect of water table:

    B

    B

    Dw

    Df

    Limit of influence

    Case I: Dw ≤ Df

    Surcharge, . w f wq D D Dg g

    Case II: Df ≤ Dw ≤ (Df + B)

    Surcharge, . Fq Dg

    In bearing capacity equation replace g by-

    w fD D

    Bg g g g

    Case III: Dw > (Df + B)

    No influence of water table.

  • 4

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    7

    IS:6403-1981 Recommendations

    Shape Factors

    1 0.2 tan 452

    fc

    Dd

    L

    f

    1 0.1 tan 452

    fq

    Dd d

    Lgf

    Inclination Factors

    Depth Factors

    Net Ultimate Bearing capacity: . . . . . 1 . . . 0.5 . . . . .nu c c c c q q q qq c N s d i q N s d i B N s d ig g g gg

    . . . .nu u c c c cq c N s d i 5.14cN For cohesive soils where,

    , ,c qN N Ng as per Vesic(1973) recommendations

    1 0.2cB

    sL

    1 0.2qB

    sL

    1 0.4B

    sLg

    For rectangle,

    1.3cs 1.2qs

    0.8 for square, 0.6 for circles sg g

    For square and circle,

    for 10of

    1qd dg for 10of

    2

    190

    o

    c qi i

    2

    1ig

    f

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    8

    Bearing Capacity Correlations with SPT-value

    Peck, Hansen, and Thornburn (1974)

    &

    IS:6403-1981 Recommendation

  • 5

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    9

    Bearing Capacity Correlations with SPT-value

    Teng (1962):

    2 21

    3 . . 5 100 . .6nu w f w

    q N B R N D R

    For Strip Footing:

    2 21

    . . 3 100 . .3nu w f w

    q N B R N D R

    For Square and Circular Footing:

    For Df > B, take Df = B

    0.5 1 1ww wf

    DR R

    D

    0.5 1 1w fw wf

    D DR R

    D

    Water Table Corrections:

    B

    B

    Dw

    Df

    Limit of influence

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    10

    Bearing Capacity Correlations with CPT-value

    0 100 200 300 400 0

    0.0625

    0.1250

    0.1675

    0. 2500

    nuq

    qc

    B (cm)

    1fD

    B

    0.50

    IS:6403-1981 Recommendation:

    Cohesionless Soil

    1.5B to

    2.0B

    B qc value is taken as

    average for this zone

    Schmertmann (1975):

    2

    kg in

    0.8 cmc

    q

    qN Ng

  • 6

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    11

    Bearing Capacity Correlations with CPT-value

    IS:6403-1981 Recommendation:

    Cohesive Soil

    Soil Type Point Resistance Values

    ( qc ) kgf/cm2 Range of Undrained Cohesion (kgf/cm2)

    Normally consolidated clays

    qc < 20 qc/18 to qc/15

    Over consolidated clays qc > 20 qc/26 to qc/22

    . . . .nu u c c c cq c N s d i

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    12

    Effective Area Method for Eccentric Loading

    B

    Df

    ey ex

    L’=L-2ey

    B’=B-2ey AF=B’L’

    yx

    V

    Me

    F

    xy

    V

    Me

    F

    In case of Moment loading

    In case of Horizontal Force at some height but the column is

    centered on the foundation

    .y Hx FHM F d

    .x Hy FHM F d

  • 7

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    Settlement

    13

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    14

    Pressure Bulb Square Footing Strip Footing

  • 8

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    15

    Newmark’s Chart

    Determine the depth, z, where you wish to calculate the stress increase

    Adopt a scale as shown in the figure Draw the footing to scale and place

    the point of interest over the center of the chart

    Count the number of elements that fall inside the footing, N

    Calculate the stress increase as:

    Point of stress calculation

    Depth = z1

    Depth = z2

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    16

    Approximate Methods

    .

    .zB L

    qB z L z

    2

    2z

    Bq

    B z

    zB

    qB z

    Rectangular Foundation:

    Square/Circular Foundation:

    Strip Foundation:

  • 9

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    17

    Settlement

    Immediate Settlement: Occurs immediately after the construction. This is computed using elasticity theory (Important for Granular soil)

    Primary Consolidation: Due to gradual dissipation of pore pressure induced by external loading and consequently expulsion of water from the soil mass, hence volume change. (Important for Inorganic clays)

    Secondary Consolidation: Occurs at constant effective stress with volume change due to rearrangement of particles. (Important for Organic soils)

    Settlement S = Se + Sc + Ss

    Immediate Settlement

    Se

    Primary Consolidation

    Sc

    Secondary Consolidation

    Ss

    For any of the above mentioned settlement calculations, we first need vertical stress increase in soil mass due to net load applied on the foundation

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    18

    Elastic settlement of Foundation

    0 0

    1H H

    e z z s x s ys

    S dz dzE

    sE Modulus of elasticity H Thickness of soil layer

    s Poisson’s ratio of soil

    Elastic settlement:

    Elastic settlement for Flexible Foundation:

    21e s fs

    qBS I

    E

    fI = influence factor: depends on the rigidity and shape of the foundation

    sE = Avg elasticity modulus of the soil for (4B) depth below foundn level

  • 10

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    19

    Steinbrenner’s Influence Factors for Settlement of the Corners of

    loaded Area LxB on Compressible Stratus of = 0.5, and Thickness Ht

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    20

    Elastic settlement of Foundation Soil Strata with Semi-infinite depth

  • 11

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    21

    Elastic settlement of Foundation

    E in kPa

    Several other sets of correlations available

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    22

    Elastic settlement of Foundation

  • 12

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    23

    Strain Influence Factor Method for Sandy Soil: Schmertmann and Hartman (1978)

    2

    1 20

    zz

    e fs

    IS C C q D z

    Eg

    1C Correction factor for foundation depth

    1 0.5 f fD q Dg g 2C Correction factor for creep effects

    q For square and circular foundation:

    For foundation with L/B >10:

    Interpolate the values for 1 < L/B < 10

    1 0.2log time in years 0.1

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    24

    Settlement due to Primary Consolidation

    log log1 1

    s c c c c o avc

    o o o c

    C H C HS

    e e

    log1

    s c o avc

    o o

    C HS

    e

    log1

    c c o avc

    o o

    C HS

    e

    For NC clay

    For OC clay o av c

    For OC clay o c o av

    c o o av

    o Average effective vertical stress before construction

    av Average increase in effective vertical stress

    c Effective pre-consolidation pressure

    oe Initial void ratio of the clay layer

    cC Compression Index

    sC Swelling Index cH Thickness of the clay layer

    1

    46av t m b

    t

    b

    m

  • 13

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    25

    Settlement Due to Secondary Consolidation

    2

    1

    log1

    cs

    p

    C H tS

    e t

    pe

    C Secondary Compression Index 2 1log

    e

    t t

    Time, t (Log scale)

    Voi

    d R

    atio

    , e

    pe

    1t 2teVoid ratio at the end of primary consolidation

    cH Thickness of Clay Layer

    Secondary consolidation settlement is more important in the case of organic and highly-compressible inorganic clays

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    26

    Total Settlement from SPT Data for Cohesionless soil

    Multiply the settlement by factor W'

  • 14

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    27

    Total Settlement from CPT Data for Cohesionless soil

    3

    2c

    o

    qC

    lnt oto

    HS

    C

    Depth profile of cone resistance can be divided in several segments of average cone resistance

    Average cone resistance can be used to calculate constant of compressibility.

    Settlement of each layer is calculated separately due to foundation loading and then added together

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    28

    Fox’s Depth Correction

    Factor for Rectangular Footings of (L)x(B) at Depth (D)

    Depth factorc Embedded

    c Surface

    S

    S

    Rigidity Factor as per IS:8009-1976

    Total settlement of

    rigid foundation

    Total settlement at the center

    of flexible foundation

    Rigidity factor 0.8

  • 15

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    Shallow Foundation Design

    29

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    30

    Common Types of Footing

    Strip footing Spread Footing

  • 16

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    31

    Common Types of Footing

    Combined Footing Raft or Mat footing

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    32

    Location and depth of Foundation

    IS:1904-1986: Minimum depth of foundation = 0.50 m. Foundation shall be placed below the zone of

    Excessive volume change due to moisture variation (usually exists within 1.5 to 3.5 m depth)

    Topsoil or organic material Unconsolidated material such as waste dump

    Foundations adjacent to flowing water (flood water, rivers, etc.) shall be protected against scouring.

    A raised water table may cause damage to the foundation by Floating the structure Reducing the effective stress beneath the foundation Water logging around the building: proper drainage system

    around the foundation may be required so that water does not accumulate.

  • 17

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    33

    Location and depth of Foundation

    Footings on surface rock or sloping rock faces Shallow rock beds: foundation on the rock surface after chipping Rock bed with slope: provide dowel bars of minimum 16 mm

    diameter and 225 mm embedment into the rock at 1 m spacing.

    Footings adjacent to existing structures Minimum horizontal distance between the foundations shall not be

    less than the width of larger footing. Otherwise, the principal of 2H:1V distribution be used to minimize influence to old structure

    Proper care is needed during excavation phase of foundation construction beyond merely depending on the 2H:1V criteria. Excavation may cause settlement to old foundation due to lateral bulging in the excavation and/or shear failure due to reduction in overburden stress in the surrounding of old foundation

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    34

    Plate Load Test – IS:1888-1982

  • 18

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    35

    Plate Load Test: Bearing Capacity

    uf f

    up p

    q B

    q B

    For cohesioless soil

    uf upq q

    For cohesive soil

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    36

    Modulus of Sub-grade Reaction

  • 19

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    37

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    38

    Differential Settlement

    Caused by variations in soil profile and structural loads

    Consider construction tolerances

    Consider best case/worst case scenarios

    Use D/ ratios

    D

    L

    = maximum settlement

    D= differential settlement

    D/ = angular distortion

  • 20

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    39

    Total and Differential Settlement for Clays

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    40

    Total and Differential Settlement for Sands

  • 21

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    41

    Design values of D/ Ratios

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    42

    How Accurate are our

    Settlement Predictions?

  • 22

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    43

    Allowable Bearing Pressure

    Maximum bearing pressure that can be applied on the soil satisfying two fundamental requirements Bearing capacity with adequate factor of safety

    – net safe bearing capacity

    Settlement within permissible limits (critical in most cases) – net safe bearing pressure

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    44

    Allowable Bearing Pressure

    Teng’s (1962) Correlation:

    depth correction factor 1 2fDD

    CB

    Sa in mm and all other dimensions in meter.

    .cor NN C N

    1.75

    for 0 1.050.7N o ao a

    C PP

    3.5

    for 1.05 2.80.7N o ao a

    C PP

    o Effective Overburden stress

    2

    0.31.4 3

    2n cor w D aB

    q N R C SB

    Net safe bearing pressure

    2kN m

  • 23

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    45

    Allowable Bearing Pressure

    Meyerhof’s (1974) Correlation:

    210.49 for 1.2 mn D aq N R S kN m B

    1 depth correction factor

    1 0.2 1.2

    D

    f

    R

    D

    B

    22

    2

    0.30.32 for 1.2 mn D a

    Bq N R S kN m B

    B

    Net safe bearing pressure

    2 depth correction factor

    1 0.33 1.33

    D

    f

    R

    D

    B

    Bowel’s (1982) Correlation: 2

    10.73 for 1.2 mn D aq N R S kN m B 2

    22

    0.30.48 for 1.2 mn D a

    Bq N R S kN m B

    B

    N-value corrected for overburden using bazaraa’s equation, but the N-value must not exceed field value

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    46

    Allowable Bearing Pressure

    IS Code recommendation: Use total settlement correlations with SPT data to determine safe bearing pressure.

    Correlations for raft foundations: Rafts are mostly safe in bearing capacity and they do not show much differential settlements as compared to isolated foundations.

    20.7 3 n w D aq N R C S kN m Teng’s Correlation:

    Peck, Hanson, and Thornburn (1974): 20.88 a net w aq C N S kN m

    Correlations using CPT data:

    Meyerhof’s correlations may be used by substituting qc/2 for N, where qc is in kg/cm2.

  • 24

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    47

    Net vs. Gross Allowable Bearing Pressure

    2 2g c c c f cQ Q B D B D Dg g Gross load

    2 2g c

    g f c c

    Q Qq D D

    B Bg g g

    2c

    n g f c c

    Qq q D D

    Bg g g

    cg g is small, so it may be neglected

    2c

    n

    Qq

    B

    Soil Soil

    cD

    fD

    2c

    a net

    Qq

    B

    2c

    g c c c

    Qq D t

    Bg g

    t

    2c

    n g f c c f

    Qq q D D t D

    Bg g g

    Usually Dc+t is much smaller than Df

    2c

    n f

    Qq D

    Bg

    2c

    a net f

    Qq D

    Bg

    2c

    a gross

    Qq

    B

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    48

    SUMMARY of Terminology

    Net Loading Intensity Pressure at the level of foundation causing actual settlement due to stress increase. This includes the weight of superstructure and foundation only.

    Ultimate Bearing capacity: Maximum gross intensity of loading that the soil can support against shear failure is called ultimate bearing capacity.

    Net Ultimate Bearing Capacity:

    Maximum net intensity of loading that the soil can support at the level of foundation.

    Gross Loading Intensity Total pressure at the level of foundation including the weight of superstructure, foundation, and the soil above foundation.

    superstructure Foundation soil

    Foundationg

    Q Q Qq

    A

    n g fq q Dg

    from

    Bearing capacity calculationuq

    nu u fq q Dg

  • 25

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    49

    SUMMARY of Terminology

    Gross Safe Bearing capacity: Maximum gross intensity of loading that the soil can safely support without the risk of shear failure.

    Safe Bearing Pressure: Maximum net intensity of loading that can be allowed on the soil without settlement exceeding the permissible limit.

    Allowable Bearing Pressure: Maximum net intensity of loading that can be allowed on the soil with no possibility of shear failure or settlement exceeding the permissible limit.

    Net Safe Bearing capacity: Maximum net intensity of loading that the soil can safely support without the risk of shear failure.

    nuns

    qq

    FOS

    gs ns fq q Dg

    from settlement analysissq

    Minimum of

    bearing capacity and

    settlement analysis

    a netq

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    50

    Loads on Foundation

    Permanent Load: This is actual service load/sustained loads of a structure which give rise stresses and deformations in the soil below the foundation causing its settlement.

    Transient Load: This momentary or sudden load imparted to a structure due to wind or seismic vibrations. Due to its transitory nature, the stresses in the soil below the foundation carried by such loads are allowed certain percentage increase over the allowable safe values.

    Dead Load: It includes the weight of the column/wall, footings, foundations, the overlaying fill but excludes the weight of the displaced soil

    Live Load: This is taken as per the specifications of IS:875 (pt-2) – 1987.

  • 26

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    51

    Loads for Proportioning and Design of Foundation IS:1904 - 1986

    Following combinations shall be used Dead load + Live load

    Dead Load + Live load + Wind/Seismic load

    For cohesive soils only 50% of actual live load is considered for design (Due to settlement being time dependent)

    For wind/seismic load < 25% of Dead + Live load Wind/seismic load is neglected and first combination is used to

    compare with safe bearing load to satisfy allowable bearing pressure

    For wind/seismic load ≥ 25% of Dead + Live load It becomes necessary to ensure that pressure due to second

    combination of load does not exceed the safe bearing capacity by more than 25%. When seismic forces are considered, the safe bearing capacity shall be increased as specified in IS: 1893 (Part-1)-2002 (see next slide). In non-cohesive soils, analysis for liquefaction and settlement under earthquake shall also be made.

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    52

  • 27

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    53

    Other considerations for Shallow Foundation Design

    For economical design, it is preferred to have square footing for vertical loads and rectangular footing for the columns carrying moment

    Allowable bearing pressure should not be very high in comparison to the net loading intensity leading to an uneconomical design.

    It is preferred to use SPT or Plate load test for cohesionless soils and undrained shear strength test for cohesive soils.

    In case of lateral loads or moments, the foundation should also be checked to be safe against sliding and overturning. The FOS shall not be less than 1.75 against sliding and 2.0 against overturning. When wind/seismic loads are considered the FOS is taken as 1.5 for both the cases.

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    54

    Combined Footings

    Combined footing is preferred when The columns are spaced too closely that if isolated footing is

    provided the soil beneath may have a part of common influence zone.

    The bearing capacity of soil is such that isolated footing design will require extent of the column foundation to go beyond the property line.

    Types of combined footings Rectangular combined footing Trapezoidal combined footing Strap beam combined footing

  • 28

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    55

    Rectangular Combined Footing

    If two or more columns are carrying almost equal loads, rectangular combined footing is provided

    Proportioning of foundation will involve the following steps

    Area of foundation

    Location of the resultant force

    For uniform distribution of pressure under the foundation, the

    resultant load should pass through the center of foundation base.

    Length of foundation, Offset on the other side,

    The width of foundation,

    1 2

    a net

    Q QA

    q

    2

    1 2

    Q Sx

    Q Q

    12L L S

    2 1 0L L S L

    B A L

    Q1 Q2

    Q1+Q2 x

    L1 S L2

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    56

    Trapezoidal Combined Footing

    If one of the columns is carrying much larger load than the other one, trapezoidal combined footing is provided

    Proportioning of foundation will involve the following steps if L, and L1 are known

    Area of foundation

    Location of the resultant force

    For uniform distribution of pressure under the foundation, the

    resultant load should pass through the center of foundation base. This gives the relationship,

    Area of the footing,

    1 2

    a net

    Q QA

    q

    2

    1 2

    Q Sx

    Q Q

    1 21

    1 2

    2

    3

    B B Lx L

    B B

    1 2

    2

    B BL A

    Solution of these two equations

    gives B1 and B2

    Q1 Q2

    Q1+Q2 x

    L1 S L2

    B1 B2

  • 29

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    57

    Strap Combined Footing

    Strap footing is used to connect an eccentrically loaded column footing to an interior column so that the moment can be transferred through the beam and have uniform stress distribution beneath both the foundations.

    This type of footing is preferred over the rectangular or trapezoidal footing if distance between the columns is relatively large.

    Some design considerations: Strap must be rigid: Istrap/Ifooting > 2. Footings should be proportioned to have approximately equal soil

    pressure in order to avoid differential settlement Strap beam should not have contact with soil to avoid soil reaction to it.

    Q1 Q2

    M2

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    Pile Foundation Design

    58

  • 30

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    63

    Load Transfer Mechanism of Piles The frictional resistance

    per unit area at any depth

    Ultimate skin friction resistance of pile

    Ultimate point load

    Ultimate load capacity in compression

    Ultimate load capacity in tension

    .z

    sz

    Qq

    S z

    perimeter of pileS

    suQ

    .pu pu pQ q A

    u pu suQ Q Q

    u suQ Q

    bearing capacity of soilpuq bearing area of pilepA

    upQ usQ

    uQ

    sQz

    z

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    64

    IS:2911 Pile Load Capacity in Cohesionless Soils

  • 31

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    65

    IS:2911 Pile Load Capacity in Cohesionless Soils

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    For Bored Piles

    For Driven Piles

    66

  • 32

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    67

    IS:2911 Pile Load Capacity in Cohesionless Soils

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    68

    IS:2911 Pile Load Capacity in Cohesionless Soils

    IS code recommends K-value to be chosen between 1 and 2 for driven piles and 1 and 1.5 for bored piles. However, it is advisable to estimate this value based on the type of construction and fair

    estimation of the disturbance to soil around pile. Typical values of ratio between K and Ko are listed below.

  • 33

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    69

    IS:2911 Pile Load Capacity in Cohesive Soils

    0.5

    For 1 0.5 , but 1 v vu uc c

    0.25

    For 1 0.5 , but 0.5 and 1 v vu uc c

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    70

    IS:2911 Pile Load Capacity in Cohesive Soils

  • 34

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    71

    Meyerhof’s Formula for Driven Piles based on SPT value

    For L/D > 10

    A limiting value of 1000 t/m2 for point bearing and 6 t/m2 is suggested

    For Sand:

    For Non-plastic silt and fine sand:

    For Clays:

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    72

    IS:2911 Pile Load Capacity in Non-Cohesive Soils Based on CPT data

    The ultimate point bearing capacity:

  • 35

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    73

    IS:2911 Pile Load Capacity in Non-Cohesive Soils Based on CPT data

    Correlation of SPT and CPT:

    The ultimate skin friction resistance:

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    74

    Allowable Pile Capacity

    Factor of Safety shall be used by giving due consideration to the following points Reliability of soil parameters used for calculation Mode of transfer of load to soil Importance of structure Allowable total and differential settlement tolerated by structure

    Factor of Safety as per IS 2911:

    uall

    QQ

    FS

  • 36

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    75

    Load Tests on Piles

    Note: Piles used for initial testing are loaded to failure or at least twice the design load. Such piles are generally not used in the final construction.

    Note: During this test pile should be loaded upto 1.5 times the working (design) load and the maximum settlement of the test should not exceed 12 mm. These piles may be used in the final construction.

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    76

    Vertical Load Test: Maintained Load Test

    The test can be initial or routine test

    The load is applied in increments of 20% of the estimated safe load. Hence the failure load is reached in 8-10 increments.

    Settlement is recorded for each increment until the rate of settlement is less than 0.1 mm/hr.

    The ultimate load is said to have reached when the final settlement is more than 10% of the diameter of pile or the settlement keeps on increasing at constant load.

  • 37

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    77

    Vertical Load Test: Maintained Load Test

    After reaching ultimate load, the load is released in decrements of 1/6th of the total load and recovery is measured until full rebound is established and next unload is done.

    After final unload the settlement is measured for 24 hrs to estimate full elastic recovery.

    Load settlement curve depends on the type of pile

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    78

    Vertical Load Test: Maintained Load Test Ultimate Load

    De Beer (1968):

    Load settlement curve is plotted in a log-log plot and it is assumed to be a bilinear relationship with its intersection as failure load

    Chin Fung Kee (1977):

    Assumes hyperbolic curve. Relationship between settlement and its division with load is taken as to be bilinear with its intersection as failure load

  • 38

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    79

    Vertical Load Test: Maintained Load Test Safe Load as per IS: 2911

    Safe Load for Single Pile:

    Safe Load for Pile Group:

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    80

    Dynamic Pile Formula for Driven Piles: Modified Hiley Formula

    . . .

    / 2uW H

    QS C

    W H

    S uQ

    Weight of hammer

    Height of fall

    Pile resistance or Pile capacity

    Pile penetration for the last blow

    Hammer fall efficiency Efficiency of blow

    Sum of temporary elastic compression of pile, dolly, packing, and ground

    C

    Note: Dynamic pile formula are not used for soft clays due to pore pressure evolution

  • 39

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    Step 1: The client/owner defines the project scope and specific project requirements.

    Step 2: The architect in consultation with the owner and sometime with structural consultants decides the overall initial layout and the type of structures to suit the owners requirements.

    Step 3: Soil Investigations and arriving at optimum foundation solutions, through continuous interaction between Foundation and Structural Consultants.

    81

    Normal Project Flow

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    Factors to consider

    How deep is good strata? Sand is Good! How is water table situation?

    What is the season when geotechnical investigation was done? (Moisture content effect, when clayey strata)

    Are there any special soil conditions? Expansive, dispersive or soft clay?

    Poorly graded soils? Gravel mix deposits!

    What is the architectural plan and what are the expected loads on different columns? Clubbing the columns into category A, B, C … based on the load

    ranges, before making decisions

    Column spacing at different locations?

    Special walls, enclosures or columns? 82

  • 40

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    Factors to consider

    Is there any variation in the strata across the building plan Change in soil type

    Inclines strata (Clays?)

    Partial fill ground

    …..?

    In case bearing capacity criteria prevails Is it total stress or effective stress analysis possible in calculation?

    What are the neighboring structures and where is the line of property?

    What are the construction requirements and constraints? Despite all that, there is uncertainty at each level

    83

    What is the allowable bearing pressure for

    different foundations?

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    Alternative Foundation Systems for Buildings

    Strip Footing Spread Footing? Combined Footing? Raft with Basement? Piled Assisted Raft System? Raft with Ground improvement?

    84

  • 41

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    Strip Footing or Spread Footing?

    Loads are relatively small (3 to 4 storey buildings) Ground is firm from shallow depth Columns loads are reasonable and well spaced Most preferred due to ease of construction Consider uniform depth as much as possible vary the

    dimensions; but depth can change if needed Plan of utilities and finished level minimum depth of

    foundation Comparison of field test data and laboratory test data

    major discrepancy means lack of confidence in design parameters find the reasons or conduct more tests

    85

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    Strip Footing or Spread Footing?

    Allowable bearing pressure varies significantly based on the size and shape of foundation 2x2 footing may have almost 2-times bearing pressure than 6x6

    footing in some cases Savings?

    One bearing pressure for the whole building is not a good option, but one depth can be good for ease of construction

    Consider differential settlement between different columns: threshold limits to be checked

    Close spacing of footings is alarming to go for alternative foundation systems Combined footing or Raft foundations

    86

  • 42

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    Foundation Systems for Taller Buildings

    87

    Raft Foundation with more Basements

    Pile Foundation With Cap

    Pile Assisted Raft Foundation

    Raft Foundation with Ground Improvement

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    Raft Foundation with more Basements

    Advantage of Gross Bearing Pressure! Thumb Rules:

    On an average per storey load is usually 1.5 tonnes and bulk density is slightly more than that

    One storey per meter of basement depth per basement three storey building with no bearing pressure requirement

    Allowable bearing pressure increases with depth

    Some bearing pressure means more storeys.

    Adjacent structures can put constraints

    88

  • 43

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    Piled-Raft Foundation

    Use of piles to reduce raft settlements and differential settlements

    Leads to considerable economy without compromising the safety and performance of the foundation.

    It makes use of both the raft and the piles, and is referred to here as a pile enhanced raft or a piled raft.

    89

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    Piled-Raft Foundation

    90

  • 44

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    Piled-Raft Foundation

    91

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    Piled-Raft Foundation

    92

    Poulos, H. G. (2001) "Piled raft foundations: design and

    applications", Geotechnique, 51(2), 95-113

  • 45

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    Design of Piled-Raft

    Design methods are available for vertical loads Lateral load response for piled raft is yet to be fully

    explored to develop design methods Moments and static lateral forces are no problem, but seismic

    forces are of concern

    There are some studies available on construction arrangements for reducing damage due to seismic forces

    Demands accuracy of pile load capacity The savings from it is worth making the effort for more of initial

    and routine pile load tests at different locations on the site

    Strategy of pile locations to reduce differential settlements

    93

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    Design Process for Piled-Raft

    Preliminary stage Assess the feasibility of using a piled raft

    number of piles to satisfy design requirements

    Second stage Assess where piles are required

    general characteristics of the piles

    Final detailed design stage Optimum number, location and configuration of the piles

    Distributions of settlement, bending moment and shear in the raft

    Pile loads and moments.

    94

  • 46

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    Pile Foundation with Cap

    Is it really required? The answer is? Is there a rock strata at shallow depth? Can it consider

    shallow foundation or ground improvement in that case?

    Is group action required to consider this option?

    Is estimation of pile capacity a concern? Is there major uncertainty about the strata?

    Is project too small?

    The raft is too small to worry about it?

    Loads too heavy?

    95

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    Raft with Ground improvement

    No extra basement and no piles! Can be highly cost effective in most cases Clayey strata below can be a problem, but solutions are:

    Stone columns, Sand pile

    Soil mixing, injection systems

    Pre-loading, vacuum loading

    Sandy or Silty strata is easier to handle Vibro-compaction

    Dynamic compaction, vibro-replacement, vibro-concrete

    Check availability and economy

    96

  • 47

    IITGN Short Course on Geotechnical Investigations for Structural Engineering

    Thank You