The General Contractor is responsible for checking all contract documents, field conditions and dimensions for accuracy and confirming that the work is buildable as shown before proceeding with construction.
1)
The GC shall verify all dimensions of any new work and shall be responsible for their accuracy. Any difference found shall be immediately reported to the Architect for consideration before proceeding with the work.
2)
Dimensions are to:Face of masonry or concrete, center line of columns, face of wall, or face of mullion unless noted otherwise.
3)
Do not scale drawings. Dimensions govern and large scale drawings govern over smaller scale drawings.
4)
Where a discrepancy exists between or within standards, Specifications, and Drawings, the more stringent or higher quality requirements shall apply. The precedence of the Construction Documents is in the following sequence:
a)Addenda and modifications to the Drawings and Specifications take precedence over the original construction documents.
b)Should there be a conflict within the Specifications or on the Drawings, the Architect shall decide which stipulation will provide the best installation and his decision shall be final.
c)Should a conflict arise between the Drawings and the Specifictions, the specification shall have precedence over the Drawings.
d) In the Drawings, the precedence shall be drawings of a larger scale over those of a smaller scale, figured dimensions over scaled dimensions, and noted materials over graphic indications.
5)
'Typ' or Typical means for all similar conditions unless otherwise noted.6)
All trades to comply with all applicable local, state, health, safety codes, ordinance, requirements etc. and provide acceptable materials and workmanship to current industry standards.
7)
Contractor is solely and completely responsible for conditions of the job site, including safety, protection of property and the like during the performance of the work.
8)
Provide facing at all thermal and sound insulating material where exposed in a return air plenum as required.
9)
All thermal and sound insulating materials, including facings such as vapor barriers installed within floor ceiling assemblies, roof-ceiling assemblies, walls, crawl spaces and not in substantial contact and behind such components shall have a flame spread index of not more than 25 and a smoke-developed index of not more than 450 per Section 719 of IBC 2012.
10)Site Location
Sheet:
Project Number:
4303 Brighton Blvd., Building #3Denver, Colorado 80216720-891-8703
General Contractor:
Owner:Cellular Sales9040 Executive Park DriveKnoxville, TN 37923Contact: Colby Smith
Structural Engineer:JVA Incorporated1319 Spruce StreetBoulder, CO 80302Contact: Jeannette Torrents
MEP Engineer:KVA Consulting10495 S. Progress Wat, Suite 202Parker, CO 80134Contact: John Tinsley
Number:
7/7
/2016 4
:23:0
5 P
M
.A0Cover
16D
Cellu
lar
Sale
s -
Superior
304 M
ars
hall
Rd.
Superior,
CO
Sheet Index
07
08
/201
5 F
or
Perm
it
Sh
ee
t N
um
ber
Sheet Name
Architecture
● .A0 Cover
● .A0.1 Code Plan
● .D1 Demolition Plan
● A1 New Work Plan
● A2 Reflected Ceiling Plan
● A3 Casework and Details
● A4 Finish Plan
● A5 Exterior Elevations
● A6 Sections and Details
Mechanical
● M0.0 Mechanical Notes & Schedules
● M1.0 Mechanical Plans
Plumbing
● P0.0 Plumbing Notes & Schedules
● P1.0 Plumbing Plans - Water
● P2.0 Plumbing Plans - Waste
Electrical
● E0.0 Electrical One-Line, Notes & Schedules
● E1.0 Power Plan
● E1.1 Data / Power Layout By Others
● E2.0 Lighting Plan
Construction Documents
Cellular Sales - Superior
July 8th, 2016
S SOUTH
SF SQUARE FEET
SIM SIMILAR
SPEC SPECIFICATION(S)
SQ SQUARE
STOR STORAGE
STRUCT
STRUCTURE orSTRUCTURAL
SYM SYMMETRICAL
T TILE
T&G TONGUE AND GROOVE
TEMP TEMPORARY
THK THICK or THICKNESS
TOS TOP OF STEEL
TYP TYPICAL
UL UNDERWRITER'SLABORATORY
UNO UNLESS NOTEDOTHERWISE
VB VAPOR BARRIER
VERT VERTICAL
VEST VESTIBULE
W WEST / WIDE
W/ WITH
W/O WITHOUT
WD WOOD
LT LIGHT
MDF MEDIUM DENSITYFIBERBOARD
MECH MECHANICAL
MEP MECHANICAL,ELECTRICAL andPLUMBING
MFR MANUFACTURER
MID MID-POINT/MIDDLE
MIN MINIMUM
MISC MISCELLANEOUS
MTL METAL
N NORTH
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NTS NOT TO SCALE
OC ON CENTER
OF-CI OWNER FURNISHED,CONTRACTORINSTALLED
OF-OI OWNER FURNISHED,OWNER INSTALLED
OPP OPPOSITE
OVHD OVERHEAD
PLAM PLASTIC LAMINATE
PNTD PAINTED
PR PAIR
PROJ PROJECT
PSF POUNDS PER SQUAREFOOT
PSI POUNDS PER SQUAREINCH
PWR POWER
QTY QUANTITY
RCP REFLECTED CEILINGPLAN
RE REFER TO orREFERENCE
REINF REINFORCING
REQD REQUIRED
REV REVISE, REVISED orREVISION
RM ROOM
ROW RIGHT OF WAY
EA EACH
EJ EXPANSION JOINT
ELEC ELECTRICAL
EQ EQUAL/EQUIVALENT
EQUIP EQUIPMENT
EXP EXPANSION
EXT EXTERIOR
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHERCABINET
FFE FINISHED FLOORELEVATION
FIN FINISH(ED)
FIXT FIXTURE
FRP FIBER RESIN PANEL)
FT FOOT/FEET
FV FIELD VERIFY
GA GAUGE
GALV GLAVANIZED
GC GENERAL CONTRACTOR
GYP GYPSUM BOARD
HDCP HANDICAP(PED)
HM HOLLOW METAL
HORIZ HORIZONTAL
HPC HIGH PERFORMANCECOATING
HR HOUR
HSS HOLLOW STRUCTURALSECTION
HT HEIGHT
HVAC HEATING, VENTILATIONand AIR CONDITIONING
IBC INTERNATIONALBUILDING CODE
IN INCH
INFO INFORMATION
INSUL INSULATION orINSULATED
JAN JANITOR
JT JOINT
L LENGTH
LAV LAVATORY
LH LEFT HAND
LKR LOCKER
# POUND(S) or NUMBER
ACM ALUMINUM COMPOSITEPANEL
ACT ACCOUSTICAL CEILINGTILE
ADA ACCESSIBLE
ADJ ADJACENT orADJUSTABLE
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLING UNIT
ALT ALTERNATE
ALUM ALUMINUM
ANG ANGLE
APPROX
APPROXIMATE(LY)
ARCH ARCHITECTURAL
ASI ARCHITECT'SSUPPLEMENTALINSTRUCTIONS
BD BOARD
BLDG BUILDING
BLKG BLOCKING
BRK BRICK
CFCI CONTRACTOR FURNISH,CONTRACTOR INSTALL
CFOI CONTRACTOR FURNISH,OWNER INSTALL
CG CORNER GUARD
CIP CAST IN PLACE
CJ CONTROL JOINT
CL CENTERLINE
CLG CEILING
CMU CONCRETE MASONRYUNIT
COL COLUMN
CONC CONCRETE
CONST
CONSTRUCTION
CONT CONTINUOUS
CONTR
CONTRACT(OR)
CORR CORRIDOR
CTR CENTER
DEPT DEPARTMENT
DIM DIMENSION
DS DOWNSPOUT
DTL DETAIL
DWG DRAWING
STANDARD ABBREVIATIONS
Issued For: Date
Permit Set 07/08/2016
GENERAL NOTES
VICINITY MAP
2376 SF79M
30 OLF
Showroom
88 SF1M
300 OLF
Storage
EXIT
EXIT
30 SF1M
300 OLF
Service / Stor.
488 SF16M
30 OLF
Back of House
Greater than 1/2 of th
e Overall B
uilding Diagonal (I
BC 1015.2.1)
55' - 7 1/4" E
xit Seperatio
n
20
' -
0"
Ma
x (
IBC
10
18
.4)
17
' - 0
" D
ead
En
d C
orr
ido
r
Overall Building Diagonal (IB
C 1015.2.1)
98' - 11"
Code Information:
Adopted Codes• 2012 International Building Code• 2012 International Residential Code• 2012 International Plumbing Code• 2012 International Fuel Gas Code• 2012 International Mechanical Code• 2012 International Fire Code• 2012 International Energy Conservation Code • 2015 National Electric Code• 2009 ICC A117.1 Accessible and Usable Buildings and Facilities
Project Scope - New Tenant infill to create a Cellular Sales retail location in a vacated Wendy's location. Remove existing fast food equipment and replace with office and showroom facility. Modify the building exterior to Cellular sales branding while still leaving many elements of the existing building.
Building Gross Square Footage: 3,561 S.F .
Type Of Construction (IBC 601)• Existing Building Construction: Type V-B
Sprinkled: No
Occupancy Classification (IBC 309.1): Mercantile Group M
Occupant Load (IBC Table 1004.1.2):• Grade Floor Areas: 30 Gross = 95 Occupants• Assembly - Unconcentrated: 15 Net = 23
1. Small Assembly (Occupant load less than 50) to be classified as Group M per IBC 303.1.2
• Storage Areas: 300 Gross = 1 Occupant• Total Occupant Load: 119 Occupants
Means of Egress Sizing (IBC 1005)• 0.2" per Occupant = 23.8"• Each Exit door provides 33" of clear space for a total of 66".
Exit Access Doorways (IBC 1015.1): Two Exits Required
Exit Access Travel Distance (IBC Table 1015.2): 200 Feet
Common Path of Egress Travel (IBC Table 1014.3): >75 Occupants = 75'.
Fire Extinguishers (IBC Section 906)• 2 Required per IBC Table 906.3(1)• Max Travel Distance: 75' per IBC Table 906.3(1)
Plumbing Facilities (IBC Table 2902.1):• Water Closets, 1 per 500 for Male and Female, 2 Provided.• Lavatories, 1 per 750 for Male and Female, 2 Provided.• 1 Sevice Sink Required, 1 Provided.• Drinking Fountains, 1 Required. We are requesting a varience for this
requirement to allow for no drinking fountain to be installed. Cellular Sales will provide a water cooler in the show room space for customer and employee use.
344 SF23M
15 OLF
Conference
FEC
FEC
Sheet:
Project Number:
4303 Brighton Blvd., Building #3Denver, Colorado 80216720-891-8703
General Contractor:
Owner:Cellular Sales9040 Executive Park DriveKnoxville, TN 37923Contact: Colby Smith
Structural Engineer:JVA Incorporated1319 Spruce StreetBoulder, CO 80302Contact: Jeannette Torrents
MEP Engineer:KVA Consulting10495 S. Progress Wat, Suite 202Parker, CO 80134Contact: John Tinsley
Number:
7/7
/2016 4
:23:0
6 P
M
.A0.1Code Plan
16D
Cellu
lar
Sale
s -
Superior
304 M
ars
hall
Rd.
Superior,
CO
Issued For: Date
Permit Set 07/08/2016
3/16" = 1'-0"1
Level 1
WH
Demolition General Notes
1. Broken (Dashed) lines indicate items to be removed. Verify existing conditions in field.
2. Report any incosistincies or any unexpected concealed conditions that conflict with the drawings to the Architect.
3. Refer to Mechanical, Electrical and Plumbing demolition notes and drawings for additional demolition requirements.
4. The contractor shall minimize interference of demolition work with ongoing business of adjacent tenants in the building. Construction areas shall be closed off to keep occupied areas free of dust and debris. Entrances to and from the existing occupied spaces shall maintain free of construction from this project. Care shall be taken to maintain system service to occupied areas, disruption to service shall be coordinated by the contractor with management of the effected tenants.
5. Contractor to maintain the existing buildings structural integrity through out. Contractor to notify the architect if any work needs to be done that may effect the integrity of an existing bearing member.
6. Patch and repair all existing floors, walls and ceilings that are disturbed by demolition work.
7. Contractor is responsible for the protection of all existing surface materials to remain during demolition and construction.
8. Contractor to appropriately dispose of all construction debris.9. Contractor to verify with owner before disposing of any existing
equipment, furniture, fixtures or systems components. Coordinate safe storage of any items the owner wants to keep and /or reuse.
10. All demolition work shall be completed in accordance with local saftey codes and OSHA requirements.
D2D2D2
D2
D2
D2
D2 D2
D4D4
D3
D3
D3
D5
D5
D6
D7
D7
D8
D8
D12
D12
D5
D14
D13
D13
D13
D13
D5
D5
D14
D14
D14
D14D14
D5
D14
D15
D10
D9
D9
D13
2
A6
D16
D16
D16
D16
D16
D17
D17
D18
D18
D18D18
D19
D19
D19 D19
Sheet:
Project Number:
4303 Brighton Blvd., Building #3Denver, Colorado 80216720-891-8703
General Contractor:
Owner:Cellular Sales9040 Executive Park DriveKnoxville, TN 37923Contact: Colby Smith
Structural Engineer:JVA Incorporated1319 Spruce StreetBoulder, CO 80302Contact: Jeannette Torrents
MEP Engineer:KVA Consulting10495 S. Progress Wat, Suite 202Parker, CO 80134Contact: John Tinsley
Number:
7/7
/2016 4
:23:0
8 P
M
.D1Demolition Plan
16D
Cellu
lar
Sale
s -
Superior
304 M
ars
hall
Rd.
Superior,
CO
3/16" = 1'-0"1
Floor Plan - Demolition
Demolition Keynote Legend
Key Value Keynote Text
D1 Remove existing wall. Remove any electrical devices and wiring, removecabling to origination point or junction box.
D2 Remove existing window system and wall assembly below the window tothe concrete floor slab.
D3 Remove existing window system and prepare opening for wall infill.
D4 Remove existing wall, window system, roof, and foundation to 8" min.below finish grade.
D5 Remove existing casework and counter.
D6 Remove mop sink, cap plumbing as required per Plumbing drawings.
D7 Remove existing furniture and fixtures, typ.
D8 Remove existing flooring. Prepare slab as required to receive new flooring.
D9 Remove concrete as required to allow for new electrical, RE Elec drawings.
D10 Remove concrete as required to allow for new plumbing, RE Plumbingdrawings.
D11 Remove existing cooler and related equipment.
D12 Remove existing bathroom fixture and accessories.
D13 Remove existing plumbing fixture, cap plumbing as required per Plumbingdrawings.
D14 Remove existing door and frame.
D15 Remove existing concrete slab as required where building bump out isremoved.
D16 Remove Existing Ceiling and all of its components including lighting,access panels, mechanical grilles, speakers, and fire alarm components.Patch and repair any damage to existing walls that are to remain prior tonew ceiling installation, RE: RCP for new work.
D17 Remove all Kitchen Equipment, including equipment and hoods.
D18 Remove existing bulkheads and soffits.
D19 Coordinate with MEP drawings for extent of removed ductwork, electrical,and mechanical systems.
D20 Remove all components of existing walk-in cooler system.
D21 Remove existing exterior wall for new window system.
3/16" = 1'-0"2
Reflected Ceiling Plan - Demolition
Issued For: Date
Permit Set 07/08/2016
A5 4
A5
A5
A5
2
3
1
± 7' - 6 1/8"4' - 6"3' - 6"7' - 2"
0' - 9 1/2"
7' - 2"
15
' - 1
1"
± 4
' -
6 3
/4"
1' -
11
"
1' -
1"
7' -
5"
8' -
6"
4' - 11"13' - 6"
8' -
8"
6' -
8"
Conference Room
106
Toilet
108
Toilet
107
Service
105
Inventory
102
Break
104
Show Room
101
Vestibule
100
W1
W1
W1
W3
W1
W3
W1
W1
A3
7
E100
107
108
102
105
E102
104
106
100
ALIG
N
Corridor
103
Cle
ar
3'-0
" M
in.
W3
W1
1
A6
3' -
0"
2' - 8"
W2
E2E3E4E4
E1
E5
E6E6
E5
E7E7
E7E7
E5
E8
02
01
0101
03 0304
09
05
06
06
06
08
07
E8E8
E8 E8 E8
E9
E9
CPT 1
B
A
A
A A
AAAA A
A6
3
A3
3
E15
10
10
10
10
10 10
11
11
11
11
11
11
5
A6
Interior Partition Types
W1
5/8" Type 'X' Gypsum Wall Board
3 5/8" Metal stud at 24" OC vertical
Non-rated Common Partition
Notes:1. Wall studs to extend 6" above highest
adjacent ceiling, provide kickers to structure @ 4'-0" O.C. typ. Gyp. bd. to extend 6" above adjacent ceiling.
PLAN
W3 & PWD-1
5/8" Type 'X' Gypsum Wall Board
6" 16 GA Metal stud at 12" OC vertical
Non-rated Inventory Partition and Ceiling
PLAN
0' - 6"
SECTION
Roof Deck Above
16 GA Cont. track w/ anchors at 32" O.C. max.
Ceiling per RCP
3/4" #9 (10GA) expanded metal chain-link, spot-welded or screwed w/ washers every 6" to metal framing
16 GA Cont. track w/ anchors at 32" O.C. max.
5/8" Fire Treated Plywood w/ Smooth face. Tape joints, sand smooth and paint.
Base per Finish Schedule
Inventory Side of Wall
W2
5/8" Type 'X' Gypsum Wall Board
3 5/8" Metal stud at 16" OC vertical
Non-rated Concealed Space
Notes:1. Wall studs to extend 6" above highest
adjacent ceiling, gyp. bd. to extend 6" above adjacent ceiling.
PLAN
Bottom chord of truss or deck above
Slip track with 2" deflection, typical @ full all height walls.
Finished floor
Continous bottom track with anchors @ 32" OC max.
Set bottom track in (2)continous beads of acoustic sealant, typ. Scheduled wall base
Scheduled wall base Bottom Track
5/8" Gypsum wall board
Batt. insulation as indicated per wall type.
* Fasten to studs to prevent material
movement and voids
New ceiling, see RCP
Scheduled wall base
Light gauge metal stud kicker @ 4'-0" secured to deck above
Gypsum wall board
6"
Sheet:
Project Number:
4303 Brighton Blvd., Building #3Denver, Colorado 80216720-891-8703
General Contractor:
Owner:Cellular Sales9040 Executive Park DriveKnoxville, TN 37923Contact: Colby Smith
Structural Engineer:JVA Incorporated1319 Spruce StreetBoulder, CO 80302Contact: Jeannette Torrents
MEP Engineer:KVA Consulting10495 S. Progress Wat, Suite 202Parker, CO 80134Contact: John Tinsley
Number:
7/7
/2016 4
:23:0
8 P
M
A1New Work Plan
16D
Cellu
lar
Sale
s -
Superior
304 M
ars
hall
Rd.
Superior,
CO
3/16" = 1'-0"1
Floor Plan - New Work
1" = 1'-0"2
Top & Bottom of Wall Details
Plan Keynote Legend
Key Value Keynote Text
01 Infill window to match existing construction. Finish exterior and interior tomatch adjacent wall finish.
02 Infill Wall to match existing adjacent construction. New foundation to matchexisting foundation, drill and epoxy (3) #5 longitudinal bars w/ 6" min.embed into existing foundation on ea side. Epoxy to be Hilti RE-500. Finishexterior and interior to match adjacent wall finish.
03 New window opening. Install new header at openings (3) 2x10 Wd. Header.
04 4" x 4" Stl Tube w/ (2) trimmers each side. 5 1/4" x 5/8" x 10" Base Pl. w/(2) 3/4" diam. expansion anchors.
05 Existing water entry location, provide a 24" x 24" access panel, coordinatelocation as require for maximum accessibility to valve assembly.
06 New Flooring, RE: Finish Plan
07 Coat Rack and Shelf, RE: Elevation.
08 Existing Shear wall to remain. Repair finish as required.
09 Existing Electrical Panels, RE: Elec drawings.
10 Wall mounted display rack by owner vendor. GC to coordinate outletplacement with plywood backing.
11 Furniture (Shown dashed), by owner.
Specialty Equipment Schedule
TypeMark Count Manufacturer Model Description Comments
E1 1 Under Counter Refrigerator OF-OI
E2 1 Server Rack OF-OI
E3 1 Cash Safe OF-OI
E4 2 Custom Safe OF-OI
E5 3 32" Flat Panel TV OF-OI
E6 4 50" Flat Panel TV OF-OI
E7 4 55" Flat Panel TV OF-OI
E8 6 40" Flat Panel TV OF-OI, Contractor to supply structure above, RE: RCP
E9 2 Semi-Recessed Fire ExtinguisherCabinet
CF-CI
E10 2 Bobrick B-5806 Code Copliant Grab Bars, 18", 36" & 42" CF-CI
E11 2 Bobrick B-165 2436 Channel Frame Mirror CF-CI
E12 2 Paper Towel Dispenser OF-OI
E13 2 Bobrick B-2721 Toilet Paper Dispenser CF-CI
E14 2 Soap Dispenser OF-OI
E15 1 Bobrick B-223 x 24 Mop and Broom Holder CF-CI
Issued For: Date
Permit Set 07/08/2016
1
A6
A.F.F.PWD-1
9' - 0" A.F.F.GWB-1
9' - 0"A.F.F.ACT-2
9' - 0"
A.F.F.ACT-2
9' - 0"
A.F.F.ACT-2
9' - 0"
A.F.F.ACT-1
10' - 0"
A.F.F.ACT-2
10' - 0"
A.F.F.ACT-2
9' - 0"
Show Room
101
Conference Room
106
Corridor
103
Break
104
Inventory
102
2
A6
C3
C1
C2
C4C4
C4
C1
C1
C1
C1
C7
C6
C6
C6
12
' -
2"
C5
A6
4
C8
5
A6
Demolition General Notes
1. Refer to Mechanical, Electrical and Plumbing drawings for ceiling fixtures.
2. Patch and repair existing walls as required at new ceiling line.
Ceiling Tyes
• ACT-1: 2x4 Lay-in Acoustical Ceiling, Armstrong Cortega Second Look with Tegular Edge.
• ACT-2: 2x4 Lay-in Acoustical Ceiling• GWB-1: 5/8" Gypsum Board on Metal Joists• PWD-1: Refer to Interior Partition types on sheet A1.
Sheet:
Project Number:
4303 Brighton Blvd., Building #3Denver, Colorado 80216720-891-8703
General Contractor:
Owner:Cellular Sales9040 Executive Park DriveKnoxville, TN 37923Contact: Colby Smith
Structural Engineer:JVA Incorporated1319 Spruce StreetBoulder, CO 80302Contact: Jeannette Torrents
MEP Engineer:KVA Consulting10495 S. Progress Wat, Suite 202Parker, CO 80134Contact: John Tinsley
Number:
7/7
/2016 4
:23:0
8 P
M
A2Reflected CeilingPlan
16D
Cellu
lar
Sale
s -
Superior
304 M
ars
hall
Rd.
Superior,
CO
3/16" = 1'-0"1
Reflected Ceiling Plan - New Work
Reflected Ceiling Plan Keynote Legend
Key Value Keynote Text
C1 Security Camera, Installed by Owner Vendor
C2 Provide (2) 3" Conduits for data cable, extend 6" on each side of hard lid.
C3 Existing Trells to remain.
C4 10'-0" Diameter suspended canopy to align with flooring below, OF-CI.
C5 Install unistrut perpendicular to the bottom of joists above, span across aminimum of (3) joists, provide 1/4" dia. x 1 1/2" lag screws into each bottomflange. Provide all thread as required by owner above ceiling for ownerprovided TV mount.
C6 Speaker, Installed by Owner Vendor
C7 Existing Ceiling to remain, replace damaged or dirty ceiling tiles asrequired.
C8 Gyp. Bd. Header @ 80" AFF
Issued For: Date
Permit Set 07/08/2016
E1
to r
im
2' -
10"
Ma
x1
' -
8"
2' -
6"
2' - 6" 2' - 6" 0' - 1"
2' - 6" 2' - 6"
5' - 1"
Trash and recycle bins, by owner
Coat rod and shelf
5' -
0"
3' - 0"
PLAM Cabinets
PLAM counter and backsplash
Undercounter fridge, by owner
Removable PLAM panel
Base per finish schedule
2
A3
1
A3
T.O
. S
pou
t
3' -
0"
ma
x.
3' -
4"
ma
x.
1' -
5"
2' -
0"
min.
1' - 5"
3' - 0" min.
1' - 6"
CL
1' -
5"
33
"-3
6"
To
p
C L
max.
1' - 0"
Re
fle
ctive
Surf
ace
3' -
4"
B.O
.3
' -
0"
Side Wall of Stall
Rear Wall of Stall
Drinking Fountains Urinals Toilets
3' - 4"
3' -
4"
1' -
6"
Varies
min.
2' - 0"
min.
3' - 6"
1' -
0"
Note: Dimensions shown are to finished face of wall.
Cleanout
min.
1' - 0"
ma
x.
2' -
10
"
3' -
8"
Soap Dispenser
3' -
10
"
To e
nsure
fo
rward
reach,
Typ.
B.O
. U
nit
3' -
0"
Feminine Products Vendor
Paper Towel Dispenser
Baby Changing Table
Electric Hand Dryer
Paper Towel Dispenser/Waste Reception
19"
1' - 0" 7" - 9"
1 1
/2"
Rear wall of stall
Lavatory Bathroom Accessories
1' - 6"
CLmin
.
15"
min.
2' - 6"
ANSI 602.4 ANSI 605.22006 IPC 405.3.1
ANSI 606.3 ANSI 308
Toilet Paper Dispenser
Sanitary Napkin Receptacle
ANSI 604.7ANSI 609.3
ANSI 603.3ANSI 604.2, 604.4, 604.5.2, 609.4ANSI 604.5.1,
Note: Equipment shown is for reference only and may not depict plumbing or specialty equipment this project.
33
"-3
6"
To
p4
" 18"
42"12" Max
40"
ANSI/ADA Standard Mounting Heights
34
" M
ax.
48
" M
ax.
10" Max.
34
" M
ax.
46
" M
ax.
24" Max.
15
" M
in.
48
" M
ax.
10" Max.
48
" M
ax.
20" Max.
34
" M
ax.
44
" M
ax.
25" Max.
34
" M
ax.
48
" M
ax.
15
" M
in.
Unobstructed Side Approach
Obstructed Side Approach
Unobstructed Front Approach
Obstructed Front Approach
ADA Reach Ranges
10"
Hose bracket
E15
2' - 0"
Silicone sealant @ top edges of basin and abutting FRP
24" X 24" Mop service basin, see plumbing 1
' -
6"
3' -
0"
4' -
0"
48" H. FRP on both walls above mop basin
Service faucet, see plumbing dwg's
Silicone sealant and trim pieces @ all edges of FRP board.
Base
4' -
9"
3"
1' - 4"
Prefinished steel bracket w/ hook & 1-1/2" wood clothes rod. Provide brackets @ 32" OC max. w/ 3/4" wood vertical backing as shown.
GC to provide 2x blocking, Typical
Continuous wood ledger @ ea. shelf, Typical.
Painted 3/4" MDF shelf w/ bullnose front edge, Typical.
1' - 0"
5' -
0"
25"
Removable wood panel to match adj. casework.
8 1
/2"
7"
Max
27
" M
ax
Adjacent base cabinet or wood end support panel to match casework.
ADA forward approach clearance per ANSI 117.1 2009
6" Max 11" Min
Wood skirt panel to match adj. casework.
11"
1' -
5"
1' - 4 1/2"
Required clear knee/toe space
Scheduled base
34
" M
ax to R
im
6 1
/4"
Backsplash per elevations and finish legend
8"
See Reflected ceiling plan for type and height.
Wire pull
2' - 1
0"
1' - 8
"2
' - 6"
3/4" substrate w/ 3mm laminate finish. Provide 3mm PVC edge banding to match laminate.
Adjustable white melamine shelving w/ plastic T edge, on adjustable metal clips
G.C. to install 2x blocking prior to installing wall finish. Verify heights w/ casework contractor. Use Fire treated lumber in required locations
E10
E13
E12
E11
E14
E10
E13
E12
E11
E14
107
108
Toilet
108
Toilet
107
W1
W1
A3
4
5
FRP Board, Continuous around perimeter of restroom, color by owner. Provide Top Cap trim, inside corner trim, and any required accessories for complete installation.
Base per finish schedule
0' -
4"
4' -
0"
E10 E13
Level 10' - 0"0
' -
4"
4' -
0"
3' -
4"
FRP Board, Continuous around perimeter of restroom, color by owner. Provide Top Cap trim, inside corner trim, and any required accessories for complete installation.
E11 E12 E10
E13
Base per finish schedule
E14
Toilet
108
Sheet:
Project Number:
4303 Brighton Blvd., Building #3Denver, Colorado 80216720-891-8703
General Contractor:
Owner:Cellular Sales9040 Executive Park DriveKnoxville, TN 37923Contact: Colby Smith
Structural Engineer:JVA Incorporated1319 Spruce StreetBoulder, CO 80302Contact: Jeannette Torrents
MEP Engineer:KVA Consulting10495 S. Progress Wat, Suite 202Parker, CO 80134Contact: John Tinsley
Number:
7/7
/2016 4
:23:0
9 P
M
A3Casework andDetails
16D
Cellu
lar
Sale
s -
Superior
304 M
ars
hall
Rd.
Superior,
CO
3/8" = 1'-0"7
Breakroom
1/2" = 1'-0"6
Mop Basin Elevation
1" = 1'-0"2
Coat Rod Shelf
Specialty Equipment Schedule
TypeMark Count Manufacturer Model Description Comments
E1 1 Under Counter Refrigerator OF-OI
E2 1 Server Rack OF-OI
E3 1 Cash Safe OF-OI
E4 2 Custom Safe OF-OI
E5 3 32" Flat Panel TV OF-OI
E6 4 50" Flat Panel TV OF-OI
E7 4 55" Flat Panel TV OF-OI
E8 6 40" Flat Panel TV OF-OI, Contractor to supply structure above, RE: RCP
E9 2 Semi-Recessed Fire ExtinguisherCabinet
CF-CI
E10 2 Bobrick B-5806 Code Copliant Grab Bars, 18", 36" & 42" CF-CI
E11 2 Bobrick B-165 2436 Channel Frame Mirror CF-CI
E12 2 Paper Towel Dispenser OF-OI
E13 2 Bobrick B-2721 Toilet Paper Dispenser CF-CI
E14 2 Soap Dispenser OF-OI
E15 1 Bobrick B-223 x 24 Mop and Broom Holder CF-CI
1" = 1'-0"1
Accessible Kitchenette - Forward Approach 1/4" = 1'-0"
3Enlarged Restrooms
3/8" = 1'-0"5
Restroom - Side Wall 3/8" = 1'-0"
4Restroom - Wet Wall
Issued For: Date
Permit Set 07/08/2016
16' - 9 3/4"16' - 9 3/4"16' - 1"
12
' -
2 1
/4"
4' -
1 1
/2"
R 5
' - 4
"
R 5' - 4"
R 9' - 4"
R 5' -
4"
R 11' - 0"
R 9' -
3"
9' - 0 1/2"
3' -
7 1
/2"
5' - 7 1/4"
6' -
3 3
/4"
CPT 1
RT 1
VCT 1
VCT 2
RT 1
CPT 1
RT 1
CPT 1
RT 1
VCT 1
CPT 2
General Notes:1. GC to repair any damaged existing walls and prepare for new finish.2. Gc to ensure concrete floor is clean and smooth before installing
finished flooring. Grind edges as needed where slab removal and pour-back occurs for new plumbing and electrical.
3. Verify all final color selections with owner.4. All floor finishes to be installed in accordance with manufacturers
specifications. Contractor to inspect slab for compatibility prior to starting.
5. All Gypsum Walls to be smooth and primed before paint is applied.
2" steel frame - Timely prefinished or painted HM per door schedule.
GWB each side per wall type.
Door. Reference door schedule
Selant at frame perimeter, typical
Metal or wood studs per partition types.
Shim Space
GWB each side per wall type.
Door. Reference door schedule
Metal or wood studs per partition types.
2x Wd. Blocking
Prehung Wd. Frame and Door
1x Wd. Trim, Paint per Sched.
2" steel frame - Prefinished by Timely or painted HM per door schedule.
Frame anchor as recommended by manf.
5/8" GWB each side
Door: reference door schedule
Sealant at frame perimeter, typical.
Provide double 20 Ga stud at jamb openings, typical
Hardware Group 11 ea. Cylinder, Key to Building Standards
Hardware Group 23 ea. Tamper Resitant 4.5" Butt Hinge w/
Non-Removable Pin and Security Tab1 ea. Latch Set - Passage Function Lockset2 ea. Deadbolt - Thumb Turn to be on Interior
of Door1 ea. Surface Closer3 ea. Door Silencer1 ea. Wall Door Stop
Hardware Group 33 ea. Hinge1 ea. Latch Set - Passage Function Lockset1 ea. Wall Door Stop
Hardware Group 41 ea. Door Pull
Hardware Group 53 ea. Hinge1 ea. Latch Set - Privacy Function Lockset1 ea. Wall Door Stop
Gerneral Hardware Notes:Lockset: Sargent, Grade 1 hardware, Style 'P Lever',
US26D Satin Chromium PlatedHinges: Full mortise hinges by McKinney or equalClosers: Surface mounted closers - Norton or equal
Door and Frame Elevations
Type 2
General Metal Frame Specifications:1. Frame: 2" welded hollow metal frame, 16 Ga. provide
anchors per mfg. recommendations, wire anchors not allowed. Finish: factory primed and field painted
2. Interior Door: Single flush-panel 18 ga. steel door. Provide clear, tempered glazing where indicated on door elevations, finish: factory primed and field painted
Interior hollow metal door and frame
Type 1
6' -
8"
3' - 0"
Interior pre-hung wood door
3' - 0"
6' -
8"
Type 3
Interior pre-hung bi-fold wood door
0' -
11
"0
' -
11
"
Align Deadbolts with top and bottom hinge
3/4" Undercut
Sheet:
Project Number:
4303 Brighton Blvd., Building #3Denver, Colorado 80216720-891-8703
General Contractor:
Owner:Cellular Sales9040 Executive Park DriveKnoxville, TN 37923Contact: Colby Smith
Structural Engineer:JVA Incorporated1319 Spruce StreetBoulder, CO 80302Contact: Jeannette Torrents
MEP Engineer:KVA Consulting10495 S. Progress Wat, Suite 202Parker, CO 80134Contact: John Tinsley
Number:
7/7
/2016 4
:23:1
0 P
M
A4Finish Plan
16D
Cellu
lar
Sale
s -
Superior
304 M
ars
hall
Rd.
Superior,
CO
3/16" = 1'-0"1
Floor Plan - Finishes
Room Finish Schedule
RoomNumber Room Name Floor Finish Base Transition N Wall S Wall E Wall W Wall Counter Comments
Level 1
100 Vestibule CPT 2 RB P1 P1 P1 P1
101 Show Room CPT 1, RT 1 RB TR 1 P1 P1 P1 P1
102 Inventory VCT 1 RB TR 1 P2 P2 P2 P2
103 Corridor RT 1 RB TR 1 P2 P2 P2 P2
104 Break VCT 2 RB TR 1 P2 P2 P2 P2 PLAM 1
105 Service VCT 1 RB TR 1 P2 P2 P2 P2
106 Conference Room CPT 2 RB TR 1 P2 P2 P2 P2
107 Toilet RT 1 RB P2 P2 P2 P2
108 Toilet RT 1 RB P2 P2 P2 P2
PLAM 1 plastic laminate Casework Laminate, TDB
Code Material Manufacturer Color / Pattern Finish Thickness Location Notes
Counters & Partition Materials
P4 Door & Trim Paint Sherwin Williams Enduring Bronze SW7055 Semi Gloss n/a
P3 Gyp. Clg. Paint Sherwin Williams Snowfall SW6000 Egg Shell n/a
P2 Back of House Wall Paint Sherwin Williams Naturel SW7542 Satin n/a
P1 Main Wall Paint Sherwin Williams Prarie Grass SW7546 Satin n/a
Code Material Manufacturer Pattern / Style Color Finish Size Description Notes
Walls
TR 1 Rubber Transition Johnsonite n/a
RB Rubber Base Armstrong Shadow Gray n/a 4" high Provide in all locations
VCT 2 Vinyl Composite Tile Armsrong Checkerboard / ExcelonField Gray 51927 &Pearl White 51803
n/a 12" x 12" Checkerboard Pattern
VCT 1 Vinyl Composite Tile Armsrong Excelon Field Gray 51927 n/a 12" x 12"
RT 1 Decorative Resilient Tile n/a 20" x 20" OF-CI Straight Lay
CPT 2 Walk Off Carpet Tile Bolyu Commercial Carpet Access Procure AX302 n/a 24" x 24" OF - CI
CPT 1 Carpet Tile n/a 24" x 24" OF - CI
Code Material Manufacturer Pattern / Style Color Finish Size Description Notes
Flooring, Base & Transitions
Material Legend
Door Schedule
DoorNumber Type
Door FireRating Hardware
Frame
CommentsDoor
NumberWidth Height Thickness Material Finish Material Finish Head Jamb
Exterior
E100 Existing
3' - 0" 7' - 0" 0' - 1 3/4" Existing Existing - 1 Existing Existing Clean Existing door, Touch-up finish as required, recaulk ifneeded.
E100
E102 Existing
3' - 6" 7' - 0" 0' - 1 3/4" Existing P4 - 1 Existing P4 Interior side of door and frame to receive P4. Recaulk if needed. E102
Interior
100 Existing
3' - 0" 6' - 8" 0' - 1 3/4" Existing Existing - - Existing Existing Clean Existing door, Touch-up finish as required. 100
102 2 3' - 0" 6' - 8" 0' - 1 3/4" HM P4 - 2 HM P4 2/A4 3/A4 102
104 1 3' - 0" 6' - 8" 0' - 1 3/4" Wood P4 - 3 Wood P4 4/A4 4/A4 104
105 3 3' - 0" 6' - 8" 0' - 1 1/2" Wood P4 - 4 Wood P4 4/A4 4/A4 105
106 1 3' - 0" 6' - 8" 0' - 1 3/4" Wood P4 - 3 Wood P4 4/A4 4/A4 106
107 1 3' - 0" 6' - 8" 0' - 1 3/4" Wood P4 - 5 Wood P4 4/A4 4/A4 107
108 1 3' - 0" 6' - 8" 0' - 1 3/4" Wood P4 - 5 Wood P4 4/A4 4/A4 108
1 1/2" = 1'-0"2
H.M. Door Head 1 1/2" = 1'-0"
4Prehung Door Jamb
1 1/2" = 1'-0"3
H.M. Door Jamb 1/4" = 1'-0"Door Hardware
1/4" = 1'-0"Door and Frame Types
Issued For: Date
Permit Set 07/08/2016
Level 10' - 0"
New Proposed Building Signage. Contractor and Signage provider to verify final Signage dimensions and ensure that they meet all development and city signage codes.
Metal Trim Band, Match Parapet Cap Color
New Exterior Wall
8" Tall Metal Parapet Cap
PT-1PT-1PT-1
PT-1PT-1
PT-2
PT-2PT-2
PT-2
New Wall Infill, Match Existing
A A
Break metal band between storfront systems, match mullion color.
Level 10' - 0"
New Proposed Building Signage. Contractor and Signage provider to verify final signage dimensions and ensure that they meet all development and city signage codes.
Metal Trim Band, Match Parapet Cap Color
New Exterior Wall
8" Tall Metal Parapet Cap
PT-1
PT-2PT-2
PT-1PT-1
PT-2
PT-1
A A
PT-2
Break metal band between storfront systems, match mullion color.
Level 10' - 0"
Main Electrical Switch Gear to remain
Existing Electric Meter to remain
Existing rooftop access ladder to remain.
Metal Flashing at edge of raised parapet wall, match parapet cap
Provide opening at rooftop ladder in new parapet cap. Leave 2" clearance on each side of access.
New Parapet Cap
Provide control joint between new and existing wall surface, typ.
E102
PT-1
PT-2
PT-2
PT-1
5
A6
Level 10' - 0"
1
A6
2
A6
Metal Trim Band, Match Parapet Cap Color
New Exterior Wall
8" Tall Metal Parapet Cap
PT-1PT-1PT-1
PT-2
PT-1
PT-2
PT-2
New Proposed Building Signage. Contractor and Signage provider to verify final signage dimensions and ensure that they meet all development and city signage codes.
A B A
Break metal band between storfront systems, match mullion color.
9' -
0"
7' - 2"
3' - 7" 3' - 7"
A
10' - 3"
9' -
0"
EQ EQ EQ
Storefront System Notes:1. Mullion color and style to match existing building standards.2. Mullions to be Thermally Broken.3. New glazing to be clear, double pane, low E glass.4. Field Verify all dimensions.5. Provide pan flashing at all sill conditions.6. Provide flexible self adhered flashing at all openings, lap flashing to ensure
water drains toward the exterior of the building.7. Caulk the exterior and interior of all window systems8. All glazing on this project to be tempered.
B
Exterior Colors:
Parapet Cap: Red,Sherwin Williams, SW6871 Positive RedPT-1: Khaki, Sherwin Williams, SW7534 OuterbanksPT-2: Gray, MAB, 10C Cool Gray
Sheet:
Project Number:
4303 Brighton Blvd., Building #3Denver, Colorado 80216720-891-8703
General Contractor:
Owner:Cellular Sales9040 Executive Park DriveKnoxville, TN 37923Contact: Colby Smith
Structural Engineer:JVA Incorporated1319 Spruce StreetBoulder, CO 80302Contact: Jeannette Torrents
MEP Engineer:KVA Consulting10495 S. Progress Wat, Suite 202Parker, CO 80134Contact: John Tinsley
Number:
7/7
/2016 4
:23:1
3 P
M
A5ExteriorElevations
16D
Cellu
lar
Sale
s -
Superior
304 M
ars
hall
Rd.
Superior,
CO
3/16" = 1'-0"1
North Elevation
3/16" = 1'-0"2
South Elevation
3/16" = 1'-0"3
East Elevation
3/16" = 1'-0"4
West Elevation
1/4" = 1'-0"5
Window Type A 1/4" = 1'-0"
6Window Type B
7Exterior Perspective
Issued For: Date
Permit Set 07/08/2016
Level 10' - 0"
New
Pa
rap
et
4' -
0"
New exterior glazing system,extend from existing head location to floor line below, RE: Elevation drawings
Repair drywall as required where existing ceiling was removed.
New EIFS wall Finish, match existing exterior EIFS assembly.
New metal parapet cap.
Extend roof insulation to be continuous to new parapet location. Match existing thickness and slope, maintain all existing drainage locations.
New roof membrane to match existing membrane in type, thickness, and color. Lap new roofing a minimum of 12" over existing roofing, extend up new parapet over top of wall and secure under new parapet cap.
19' - 0"
New flooring per finish plan
New lay-in ceiling, RE: RCP
Min.
1' - 0"
10' - 0"
CL of Roof Joist @ Par Condition1' - 6" When Perp. to Roof Joist.
Roofing Note:All roofing renovations need to match the existing roofing type, brand, and detailing. GC to verify any existing roof guarantees and warranties and use manufactures standard details for all new flashings, overlays, tie-ins, penetrations and repairs. Coordinate any required inspections with the manufacturer to ensure continuation of all active guarantees and warranties.
Metal Trim Band, Match Parapet Cap Color
3/8" Dia x 3 3/8" Lag @ 2'-0" O.C. max into top plate
3/8" Dia x 3 3/8" Lag @ 2'-0" O.C. max into roof joist top flange
Double 2x6 parapet wall
Level 10' - 0"
Demo and remove existing wall under existing storefront glazing system. Salvage rock veneer to be used at exterior wall Infill as needed.
Existing header to remain
Demo and remove existing sloped roof and associated parapet wall, typ.
Demo and remove existing curved roof sections and associated trim pieces. Prepare wall behind to receive new EIFS wall system.
Demo and remove existing storefront system.
Existing Foundation to remain.
Existing structure to remain
Existing roof deck to remain
Demo and remove existing ceiling and lighting, RE: RCP
2X6 stud shear wall w/ 7/16 OSB ea side, fasten w/ 8d @ 3" w/ (4) 2X6 anchor studs ea side. Provide Simpson HD9B hold down w/ 7/8" dia anchor, drill and epoxy w/ Hilti RE-500 (8" min embed into existing concrete foundation wall) and (3) 7/8" dia thru bolts into studs.
Exterior of wall to match building construction, materials and finishes.
5/8" gypsum board.
Existing Exterior wall to remain
New Shear Wall
Existing double 2x6 header at RTU opening
New 24" TJI 560D header w/ MIU3.56/20 hanger ea end.
New 24" TJI 560D joist
Simpson MIU3.56/20 hanger
4x6x7'-6" Top Plate w/ (3) rows 8d @ 6"
Existing TJI's
Level 10' - 0"
New
Pa
rap
et
4' -
0"
Repair drywall as required where existing ceiling was removed.
New metal parapet cap.
Extend roof insulation to be continuous to new parapet location. Match existing thickness and slope, maintain all existing drainage locations.
New roof membrane to match existing membrane in type, thickness, and color. Lap new roofing a minimum of 12" over existing roofing, extend up new parapet over top of wall and secure under new parapet cap.
19' - 0"
New flooring per finish plan
New lay-in ceiling, RE: RCP
Min.
1' - 0"
3/8" Dia x 3 3/8" Lag @ 2'-0" O.C. max into top plate
3/8" Dia x 3 3/8" Lag @ each roof joist top flange
Double 2x6 parapet wall
Toilet
107
FRP
1/2" / 1'-0"
1' - 6" @ Perp to Joist
New EIFS wall Finish, match existing exterior EIFS assembly. Provide control joint between new and old.
Sheet:
Project Number:
4303 Brighton Blvd., Building #3Denver, Colorado 80216720-891-8703
General Contractor:
Owner:Cellular Sales9040 Executive Park DriveKnoxville, TN 37923Contact: Colby Smith
Structural Engineer:JVA Incorporated1319 Spruce StreetBoulder, CO 80302Contact: Jeannette Torrents
MEP Engineer:KVA Consulting10495 S. Progress Wat, Suite 202Parker, CO 80134Contact: John Tinsley
Number:
7/7
/2016 4
:23:1
3 P
M
A6Sections andDetails
16D
Cellu
lar
Sale
s -
Superior
304 M
ars
hall
Rd.
Superior,
CO
1/2" = 1'-0"1
Wall Section - New Work 1/2" = 1'-0"
2Wall Section - Demolition
1/2" = 1'-0"3
Shear Wall Detail
1/2" = 1'-0"4
Shear Wall / Joist Plan Above Ceiling
1/2" = 1'-0"5
Wall Section - New Work
Issued For: Date
Permit Set 07/08/2016
MECHANICAL SPECIFICATIONSTHE DRAWINGS INDICATE DIAGRAMMATICALLY THE EXTENT, GENERAL CHARACTER, AND LOCATION OF THEWORK INCLUDED. OFFSETS AND/OR CHANGES IN ELEVATION OF PIPING AND DUCTWORK DUE TOSTRUCTURAL OR OTHER INTERFERENCES SHALL BE PROVIDED WITHOUT EXTRA COST.
VERIFY AND EVALUATE ALL EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF WORK.
PROVIDE ALL LABOR, MATERIALS AND EQUIPMENT NECESSARY FOR THE INSTALLATION OF A COMPLETE ANDOPERATING SYSTEM. PROVIDE CONTROL WIRING NECESSARY FOR THE OPERATION OF THE MECHANICALSYSTEMS INDICATED ON THE MECHANICAL DRAWINGS. THIS SHALL INCLUDE, BUT NOT BE LIMITED TO,THERMOSTATS.
ENTIRE NEW WORK INSTALLATION SHALL CONFORM WITH ALL APPLICABLE LAWS, CODES AND REGULATIONSOF MUNICIPAL, STATE AND FEDERAL AUTHORITIES INCLUDING: THE 2012 INTERNATIONAL BUILDING,MECHANICAL, AND ENERGY CONSERVATION CODES; ANY AND ALL LOCAL AMENDMENTS ADOPTED ANDENFORCED BY THE LOCAL JURISDICTION; ASME; ASTM; ASHRAE; SMACNA; AND NFPA.
WHERE REQUIRED BY CODE, ALL WORK MUST BE INSPECTED AND APPROVED BY LOCAL AUTHORITIES. PRIOR TOFINAL ACCEPTANCE, FURNISH THE ARCHITECT/OWNER WITH CERTIFICATES OF INSPECTION AND APPROVALS BYLOCAL AUTHORITIES.
PROVIDE ALL DAMPER CONTROL HANDLES, ELECTRIC CONTROLS, AIR CONTROLS, MECHANICAL EQUIPMENT,AND OTHER APPARATUS THAT MUST BE PROVIDED IN AN INACCESSIBLE LOCATION WITH SUITABLE ACCESSDOORS OR COVERS IN A FRAMED OPENING, WHICH WILL PERMIT PROPER OPERATION AND SERVICING.
BEFORE ACCEPTANCE AND FINAL PAYMENT, DEMONSTRATE THAT ALL APPARATUS ARE FUNCTIONING PROPERLYAND EFFICIENTLY. STARTUPS AND ADJUSTMENTS FOR THE FIRST HEATING AND THE FIRST COOLING SEASONSHALL BE INCLUDED IN THE BID.
SYSTEM, MATERIAL, AND WORKMANSHIP SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR AFTER THECOMPLETION AND ACCEPTANCE. REPLACE ALL DEFECTIVE WORKMANSHIP, EQUIPMENT AND MATERIALSWITHOUT ADDITIONAL CHARGES, INCLUDING REFRIGERANT THAT IS LOST DURING RELATED REPAIRS.
TESTING, ADJUSTING, AND BALANCING SHALL BE PERFORMED IN ACCORDANCE WITH THE MOST CURRENTASHRAE HANDBOOK OF HVAC APPLICATIONS, CHAPTER 36. THIS SHALL INCLUDE, BUT NOT BE LIMITED TO:* BALANCING AIR DISTRIBUTION SYSTEMS* ADJUSTING THE TOTAL SYSTEM TO PROVIDE DESIGN QUANTITIES* ELECTRICAL MEASUREMENT* ESTABLISHING QUANTITATIVE PERFORMANCE OF ALL HVAC EQUIPMENT* VERIFYING AUTOMATIC CONTROLS
ADJUST AIR FLOWS FOR TERMINALS TO WITHIN +/- 10%. ADJUST AIR FLOWS IN DUCT MAINS TO WITHIN +/-5%, USING THE PITOT-TUBE TRANSVERSE METHOD. FURNISH TO THE ARCHITECT, FIVE (5) COPIES OF THETESTING AND BALANCING REPORT.
DUCTWORK SHALL BE GALVANIZED STEEL, CONSTRUCTED, INSTALLED, AND SUPPORTED IN ACCORDANCE WITHTHE "SMACNA" APPLICABLE MANUALS. ALL DUCTWORK SHALL BE THE LOW VELOCITY TYPE, UNLESS OTHERWISESPECIFIED. WHERE DUCTWORK IS EXPOSED TO VIEW, SUPPORT WITH THREADED ROD HANGER AND UNISTRUT.UNISTRUT SHALL HAVE (HOT-DIPPED GALVANIZED, GREEN) FACTORY FINISH.
ALL DUCT TAKE-OFFS SHALL BE PROVIDED WITH A MANUAL DAMPER. SUFFICIENT MANUAL DAMPERS SHALL BEPROVIDED AND INSTALLED FOR BALANCING OF THE SUPPLY AIR SYSTEM AND THE OUTSIDE AIR/ RETURN AIRSYSTEMS.
ALL EQUIPMENT SHALL BE INSTALLED IN STRICT COMPLIANCE WITH THE MANUFACTURER'S PUBLISHEDINSTRUCTIONS AND SHALL PROVIDE EXTRA MATERIALS REQUIRED FOR A PROPER INSTALLATION.
DUCT JOINTS FOR LOW PRESSURE DUCTWORK SHALL BE SEALED TO MEET THE SMACNA 1" W.C. PRESSURECLASSIFICATION. SEAL ALL TRANSVERSE JOINTS WITH IRON-GRIP 601 AS MANUFACTURED BY HARDCAST. APPLYPER MANUFACTURER'S INSTRUCTIONS. DUCT TAPE IS NOT AN ACCEPTABLE MEANS OF SEALING DUCTS.EXCEPTION: DO NOT SEAL EXPOSED DUCTWORK.
DUCT DIMENSIONS SHOWN ARE SHEET METAL OR WHERE LINED INTERNAL DIMENSIONS (UNLESS OTHERWISENOTED). DUCT DIMENSIONS MAY BE CHANGED IF THE NET FREE FACE AREA IS MAINTAINED.
ALL DUCT CONNECTIONS TO FAN DRIVEN UNITS SHALL BE MADE WITH 4-IN. LONG FIREPROOF FLEXIBLE DUCTCONNECTOR FOR VIBRATION SOUND ISOLATION.
CONDENSATE PIPING ABOVE THE ROOF SHALL BE PVC PIPE, ASTM D 2665, SOLID-WALL DRAIN, WASTE ANDVENT PIPING WITH PVC SOCKET FITTINGS COMPLYING WITH ASTM D 2665, SOCKET TYPE, MADE TO ASTM D3311, DRAIN, WASTE, AND VENT PATTERNS. FOR EACH ROOFTOP UNIT, PROVIDE TRAP AT CONDENSATECONNECTION AND PIPE TO NEAREST ROOF DRAIN OR SCUPPER INLET.
THIS WORK SHALL BE PERFORMED IN A CLEAN AND PROFESSIONAL MANNER. CARE SHALL BE EXERCISED TOMINIMIZE INCONVENIENCE OR DISTURBANCE TO OTHER TRADES DURING CONSTRUCTION. ISOLATE WORKAREAS BY MEANS OF TEMPORARY PARTITIONS AND/OR TARPS TO KEEP DUST AND DEBRIS WITHIN THECONSTRUCTION AREA. CLEAN THE JOB SITE DAILY AND REMOVE FROM THE PREMISES ANY DIRT AND DEBRISCAUSED BY THE PERFORMANCE OF THE WORK INCLUDED IN THIS CONTRACT.
FIELD VERIFY ALL DIMENSIONS, EXISTING CONDITIONS, AND BUILDING POWER, VOLTAGE, AND PHASE PRIORTO ORDERING EQUIPMENT AND PROCEEDING WITH ANY WORK. WHERE DISCREPANCIES OCCUR BETWEENTHESE DOCUMENTS AND EXISTING CONDITIONS, THE DISCREPANCY SHALL BE REPORTED TO THE OWNER ANDMECHANICAL ENGINEER IMMEDIATELY FOR RESOLUTION.
THIS CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFEKEEPING OF HIS/HER OWN PROPERTY ON THE JOBSITE. THE OWNER OR TENANT ASSUMES NO RESPONSIBILITY FOR PROTECTION OF THIS CONTRACTOR'SPROPERTY AGAINST FIRE, THEFT, OR ENVIRONMENTAL CONDITIONS.
WHERE CONDUIT, CABLES, DUCTWORK OR PIPING PASSES THROUGH FIRE RATED FLOORS, WALLS, ORPARTITIONS, THE SLEEVES SHALL BE COMPLETELY SEALED WITH A FIRE STOP MATERIAL THAT IS U.L. LISTED (EQUALTO DOW CORNING) AND ACCEPTED BY THE BUILDING DEPARTMENT AND FIRE DEPARTMENT AS BEINGSUITABLE FOR THE SERVICE. THIS MATERIAL SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'SPUBLISHED INSTRUCTIONS IN ORDER TO MAINTAIN THE FIRE RATING OF THE PENETRATED WALL, FLOOR, ORPARTITION. INSTALLATION SHALL BE A THROUGH-PENETRATION FIRESTOP SYSTEM INSTALLED AS TESTED INACCORDANCE WITH ASTM E 814 AND UL 1479. THE FIRE RATING SHALL MATCH THE RATING OF THE BARRIERBEING PENETRATED.
SUBMIT (1) PDF FILE OR SIX (6) SETS OF SHOP DRAWINGS, CONTROL DIAGRAMS, AND EQUIPMENT CUTS TOTHE MECHANICAL ENGINEER FOR APPROVAL PRIOR TO STARTING RELATED WORK. UPON COMPLETION OFCONSTRUCTION, SUPPLY THE MECHANICAL ENGINEER WITH ONE COMPLETE SET OF FULL SIZE AS-BUILTDRAWINGS AND ONE FULL SIZED PDF FILE. PROVIDE THE OWNER WITH (1) PDF AND THREE (3) SETS OFOPERATION AND MAINTENANCE MANUALS FOR EACH TYPE OF EQUIPMENT INSTALLED.
SUBMISSION OF PROPOSAL IN CONNECTION WITH THIS WORK SHALL IMPLY THAT THE BIDDER HAS EXAMINEDTHE JOB SITE. NO EXTRA CHARGE WILL BE ALLOWED FOR CHANGES AS A RESULT FROM FAILURE TO EXAMINETHE JOB SITE.
THIS CONTRACTOR SHALL SECURE AND PAY ALL FEES AND PERMITS PERTAINING TO THIS CONTRACT, SHALL BERESPONSIBLE FOR WORKER'S IDENTIFICATION AND BADGING, SAFETY, AND LIABILITY INSURANCE. PROVIDEBARRICADES, WARNING SIGNS, AND TRASH REMOVAL FOR THE SAFETY OF THE WORKERS UNDER THISCONTRACTOR'S EMPLOY.
THIS CONTRACTOR SHALL ASSUME ALL ADDED EXPENSES TO ALL TRADES ASSOCIATED WITH THE INSTALLATIONOF SUBMITTED AND APPROVED ALTERNATE EQUIPMENT.
DUCT INSULATION:
RECTANGULAR SUPPLY AND RETURN DUCTWORK CONCEALED ABOVE CEILINGS SHALL BE, INSULATED WITH AMINIMUM INSTALLED R-VALUE OF 6, INTERNALLY LINED WITH ACOUSTICAL LINER EQUAL TO JOHNS MANVILLELINACOUSTIC RC FIBERGLASS DUCT LINER WITH REINFORCED COATING SYSTEM 1-1/2 INCHES THICK, R-6.3,NFPA 90A AND 90B COMPLIANT.
ROUND SUPPLY AND RETURN AIR DUCTWORK CONCEALED ABOVE CEILINGS SHALL BE INSULATED WITHFIBERGLASS DUCT INSULATION WITH FSK FACING EQUAL TO JOHNS MANVILLE MICROLITE, 100# DENSITY, 2INCHES THICK, WITH A MINIMUM INSTALLED R-VALUE OF 6. INSTALL PER MANUFACTURER'S PUBLISHEDINSTRUCTIONS. DUCTWORK THAT IS ACOUSTICALLY LINED DOES NOT REQUIRE EXTERIOR INSULATION.
EXTERIOR DUCTWORK SHALL BE INSULATED WITH A MINIMUM INSTALLED R-VALUE OF 8.
EXPOSED DUCTWORK WITHIN CONDITIONED SPACE SHALL NOT BE EXTERNALLY INSULATED. CLEAN AND PREPFOR PAINTING (PAINT BY OTHERS).
WHERE DUCTWORK IS NOTED TO BE INSULATED DIFFERENTLY ON THE DRAWINGS (i.e. EXTERNAL INSULATIONON RECTANGULAR DUCTWORK), THE CORRESPONDING INSULATION SPECIFICATIONS ABOVE SHALL APPLY.
GREASE EXHAUST DUCT SHALL BE CONSTRUCTED OF 16 GAGE WELDED BLACK IRON AND SHALL BE EXTERNALLYWRAPPED IN 2 LAYERS OF U.L. LISTED GREASE DUCT WRAP UP TOP ROOF PENETRATION. HORIZONTAL GREASEEXHAUST DUCT SHALL BE PROVIDED WITH RATED CLEANOUTS PER MECHANICAL CODE.
INSIDE CLEAR INSULATIONDIMENSION
1RTU EQUIPMENT MARK
(SEE SCHEDULES)
12x12
FIRE DAMPER
VOLUME DAMPER (TYP)
RECTANGULAR DUCTSIDE CONNECTION OF
GALV STEEL DUCT
INSUL FLEX ROUND DUCT
SIDE CONNECTION OF
TOP (OR BOTTOM) CONN
ROUND DUCT
OF ROUND DUCTROUND DUCT SECTION UP
TRUNK DUCT ELBOW(TURNING VANES REQ'D)
ROUND DUCT SECTION DN
RETURN OR EXHAUST DUCT DN
RETURN OR EXHAUST DUCT UP
0.5A
A
DESCRIPTION
SUPPLY DUCT UP
SUPPLY DUCT DN
SYMBOL
H.V.A.C. LEGEND
EXISTG DUCT
EXISTG ROUND DUCT
EXISTING(E)
DESCRIPTIONSYMBOL
CONNECT NEW TO EXISITNG
VENTILATION SCHEDULE(PER 2012 IMC, TABLE 403.3)
ROOM NAME(S)
CONFERENCE ROOMS
INVENTORY RM 102
STORAGE ROOMS
SALES (except as below)
CORRIDORS
VESTIBULE
BREAK ROOM* OUTSIDE AIR PER SQ. FT. CALCULATED BY THE USE OF EQUATION 4-1 AND EQUATION 4-2 OF IMC.NOTES:a. Based upon net occupiable floor area.
OCCUPANCY
CLASSIFICATION
CONFERENCE ROOMS
STORAGE ROOMS
STORAGE ROOMS
SALES (except as below)
CORRIDORS
MAIN ENTRY LOBBIES
OFFICE SPACES
ROOM
AREA
(SF)
335
78
27
2306
243
39
86
PERSONS
PER 1000 SF
50
15
10
5
Rp
PEOPLE
AIRFLOW
5
7.5
5
5
Ra
ZONE
AIRFLOW
0.06
0.12
0.12
0.12
0.06
0.06
0.06
Exhaust
AIRFLOW
RATE CFM/SF
TOTAL
PERSONS
17
0
0
35
0
1
1
ZONE
Ez
0.8
0.8
0.8
0.8
0.8
0.8
0.8
OUTSIDE AIR
PER SQ. FT.
PER IMC*
0.39
0.15
0.15
0.29
0.08
0.14
0.11
OUTSIDE AIR
REQUIRED
(CFM)
130
12
4
670
18
5
9
%OSA OF
SUPPLYING RTU
(CFM)
20.0%
20.0%
20.0%
20.0%
20.0%
20.0%
20.0%
MIN SUPPLY
REQUIRED
(CFM)
649
59
20
3351
91
27
46
SUPPLY
PROVIDED
1050
125
50
4100
225
250
200
EXHAUST
ROOFTOP UNIT SCHEDULE (GAS-FIRED) Carrier
Mark(s)
RTU-1
RTU-2
NOTES:
Manufacturer / Model No.
Carrier TMF008
Carrier TMF008
1. Provide Duct mounted smoke detectors in supply duct per code, when unit supplies equal or greater than 2000 CFM.
2. Provide 14" in. high manufacturer's roof curb, flash and seal to roof.
3. Provide 100% enthalpy controlled economizer, set to minimum outside air requirements as shown on Ventilation Schedule.
4. Provide Honeywell T-7300 programmable thermostat with locking cover.
NOM.TONS
7.5
7.5
EER
10.1
10.1
COOLING
Sens
64.4
64.4
Total
85.2
85.2
AMB.AIR
TEMP
105
105
EATDB
ºF
85
85
WB
ºF
67
67
Input
MBH (SL)
224
224
HEATINGOutput
MBH (SL)
179
179
Output
MBH (ALT)
143
143
SUPPLY FAN
CFM
3000
3000
ESP
0.5
0.5
SUPPLY
FAN (HP)
3.00
3.00
VOLTAGE
& PHASE
208/3
208/3
ELECTRICAL
MCA
44.9
44.9
MOCP
50
50
LENGTH
(IN)
87 3/8"
87 3/8"
SIZEWIDTH
(IN)
57 3/4"
57 3/4"
HEIGHT
(IN)
41 5/16"
41 5/16"
WEIGHT
(LBS)
1115
1115
EXHAUST FAN SCHEDULE
MARK(S)
EF-1
EF-2
EF-3
NOTES:
FAN CONTROL:
MANUFACTURER/MODEL
Greenheck - SPA-110
Greenheck - SPA-110
Greenheck - SPA-110
1. Intergral gravity backdraft damper
7. 12" Manufacturer's roof curb
A. Separate wall switch
LOCATION
Ceiling
Ceiling
Ceiling
8. 18" Manufacturer's ventilated roof curb
B. Switch on with lights
SERVING
Restroom
Restroom
Mop Sink
2. Ducted from fan outlet to roof
CFM
75
75
75
C. 24/7 time clock to operate during occupied times
ESPin
0.25
0.25
0.25
3. SMACNA approved roof cap
Wattsor HP
49
49
49
MOTORVoltage &
Phase
115/1
115/1
115/1
RPM
750
750
750
4. Ducted from fan outlet to wall
DamperType
Backdraft
Backdraft
Backdraft
D. Continuous operation
FanControl
B
B
C
5. Wall exhaust louver, see plans for size
ROOFOPENING
in x in
6"dia thru roof
6"dia thru roof
6"dia thru roof
E. Interlock with equipment (Marks shown)
WEIGHT
lbs.
17
17
17
6. 1/4" galv. mesh birdscreen
NOTESlbs.
1, 2, 6
1, 2, 6
1, 2, 6
DIFFUSER, REGISTER & GRILLE SCHEDULE
Mark(s)
CD1
CD2
CD3
RG1
RG2
RG3
EG1
Manufacturer / Model No.
Titus TMS or equal
Titus MCD or equal
Titus MCD or equal
Titus 50F
Titus 50F
Titus 355 RL
Titus 350 RL
DESCRIPTION
T-Bar Ceiling Diffuser
Modular Core Ceiling Diffuser
Modular Core Ceiling Diffuser
T-Bar Eggcrate Return Grille
T-Bar Eggcrate Return Grille
Ceiling Return
Ceiling Exhaust
CONSTRUCTION
Steel
Steel
Steel
Aluminum
Aluminum
Steel
Steel
NOM. CFM
50-300
100
50
840-1200
80-120
80
75
NECK SIZE
See Plans
6"
4"
--
--
--
See Plans
SIZE
24"x24"
12"x12"
6"x4"
24"x24"
24"x12"
12"x12"
12"x12"
MOUNTING
T-Bar Lay-in
Surface mount
Surface mount
T-Bar Lay-in
T-Bar Lay-in
Surface mount
T-Bar Lay-in
REMARKS
Paintable, color per Architect
4-way pattern unless otherwise noted
4-way pattern unless otherwise noted
1/2" x 1/2" x 1/2" steel core
1/2" x 1/2" x 1/2" steel core
35 deg. fixed blades
35 deg. fixed blades
M0.03 ROOF TOP UNIT DETAIL
NTS
ROOF CURB
RETURN AIR DUCT
FLEXIBLE CONNECTION MAX. 25 FLAME/50SMOKE INDEX.
CONDENSATE DRAIN WITH CLEANOUT &DEEP SEAL TRAP PER MANUFACTURER'SRECOMMENDATIONS.
PACK OPENING BETWEEN ROOF DECK AND DUCTS & ENTIRECURB CAVITY WITH FIBERGLASS INSULATION. PROVIDESHEETMETAL ENCLOSURE AT DUCT PENETRATION OF METALROOF DECK TO COVER UP & HOLD INSULATION IN PLACE.
ROOF TOPUNIT
SMOKE DETECTOR IN R/A DUCT BY E.C.WIRE TO SHUT DOWN UNIT WHENSMOKE IS DETECTED
SUPPLY AIR DUCT
SCALE:M0.02 DUCT HANGER DETAIL
NONECONTRACTOR SHALL PROVIDE DUCT HANGERS AND CONNECTION TOSTRUCTURE AS PART OF MECHANICAL SUBMITTAL.
HANGER STRAP20 GAUGE MIN.
50" DIA.MAX
BAND OF SAMESIZE AS HANGERSTRAP
HANGER STRAPS(20 GAUGE MIN)
60" MAX
1" MIN.
UNLESS FOOT OFSTRAP IS PLACED
UNDER A BOTTOMREINFORCEMENT
SCREWS(TYP)
SCREWS MAY BE OMITTED IFHANGER LOOPS ALL AROUND
UNDERSIDE OF DUCT
REFERENCE:SMACNA HVAC DUCTCONSTRUCTION STANDARDS
NOTE:SIZE STRAP AND HANGER ROD PERLATEST EDITION OF SMACNA DUCTCONSTRUCTION STANDARDS.
SCALE:M0.01 SPIRAL DUCT REGISTER DETAIL - ANGLE
NONE
GRINNEL #290 GALV. EYELET NUT &3/8"Ø ALL THREAD MOUNTED WITHEYELET & BOLT ATTACHED TO PURLINSABOVE WITH GALV. SIDE BEAMBRACKETS. CONTRACTOR SHALLPROVIDE DUCT HANGERS ANDCONNECTION TO STRUCTURE AS PARTOF MECHANICAL SUBMITTAL.
SHEET METALSTRAPS EQUALLY
SPACED PERARCHITECTURAL
DRAWINGS
ROUND SPIRAL DUCTSEE PLAN FOR SIZE.
SPIRAL DUCT SUPPLY REGISTERWITH SCOOP DAMPER
23°23°
UTILIZE FOR ALL EXPOSED SPIRAL DUCTWORK.
M0.0MECHANICAL NOTES &
SCHEDULES
Sheet:
Project Number:
4303 Brighton Blvd., Building #3Denver, Colorado 80216720-891-8703
General Contractor:
Owner:Cellular Sales9040 Executive Park DriveKnoxville, TN 37923Contact: Colby Smith
Structural Engineer:
MEP Engineer:
Number:
7/4/
2016
12:
56:4
2 P
M
kVA 16-077
Cel
lula
r Sal
es -
Sup
erio
r30
4 M
arsh
all R
d.S
uper
ior,
CO
Issued For: DatePERMIT 07.08.16
#
SCALE:M1.01 MECHANICAL PLAN
1/4" = 1'-0"
Show Room101
Conference Room106
Corridor103
Break104
Inventory102
ProjectNorth
1
1
1
RG1880CFM
RT
1
RT
1
2
2
3
3
4
(TYP.)
4
(TYP.) 4
(TYP.)
4
(TYP.)
4
(TYP.)
4
(TYP.)
4
(TYP.)
DIFFUSER ROUND NECK SIZENOMINAL CFM
0-5051-125
126-200201-325326-475476-650
NECK DIA.4"ø6"ø8"ø10"ø12"ø14"ø
M1.0MECHANICAL PLANS
Sheet:
Project Number:
4303 Brighton Blvd., Building #3Denver, Colorado 80216720-891-8703
General Contractor:
Owner:Cellular Sales9040 Executive Park DriveKnoxville, TN 37923Contact: Colby Smith
Structural Engineer:
MEP Engineer:
Number:
7/4/
2016
12:
56:4
2 P
M
kVA 16-077
Cel
lula
r Sal
es -
Sup
erio
r30
4 M
arsh
all R
d.S
uper
ior,
CO
Issued For: DatePERMIT 07.08.16
1.1 SUMMARY: PROVIDE PLUMBING WHERE SHOWN ON THEDRAWINGS, AS SPECIFIED HEREIN, AND AS NEEDED FOR A COMPLETEAND PROPER INSTALLATION INCLUDING, BUT NOT NECESSARILYLIMITED TO:
DOMESTIC HOT AND COLD WATER PIPING SYSTEMS
DRAIN, WASTE, AND VENT SYSTEMS
PLUMBING FIXTURES AND TRIM AS SHOWN ON THE DRAWINGS
FUEL GAS PIPING SYSTEM
STORM DRAINAGE SYSTEMS
DOCUMENTS AFFECTING WORK OF THIS SECTION INCLUDE, BUT ARENOT NECESSARILY LIMITED TO GENERAL CONDITIONS,SUPPLEMENTARY CONDITIONS, AND SECTIONS IN DIVISION 1 OF THEARCHITECTURAL SPECIFICATIONS.
1.2 SUBMITTALS: COMPLY WITH PERTINENT PROVISIONS OF DIVISION 1AND THE ARCHITECTURAL SCOPE.
PRODUCT DATA: WITHIN 30 CALENDAR DAYS AFTER THE CONTRACTORHAS RECEIVED THE OWNER'S NOTICE TO PROCEED, SUBMIT:
MATERIALS LIST OF ITEMS PROPOSED TO BE PROVIDED UNDER THISSECTION
MANUFACTURER'S SPECIFICATIONS, CATALOG CUTS, AND OTHER DATANEEDED TO PROVE COMPLIANCE WITH THE SPECIFIED REQUIREMENTS.
SHOP DRAWINGS AND OTHER DATA AS REQUIRED TO INDICATEMETHOD OF INSTALLING AND ATTACHING EQUIPMENT, EXCEPT WHERESUCH DETAILS ARE FULLY SHOWN ON THE DRAWINGS.
STERILIZATION CERTIFICATE: UPON COMPLETION OF DOMESTICWATER PIPING SYSTEM, THE ADDED PORTION OF THE SYSTEM SHALL BESTERILIZED. UPON COMPLETION THE CONTRACTOR SHALL DELIVER TOTHE ARCHITECT TWO (2) COPIES OF AN ACCEPTABLE "CERTIFICATE OFPERFORMANCE" FOR THIS ACTIVITY.
UPON COMPLETION OF THE WORK OF THIS SECTION, DELIVER TO THEARCHITECT FOUR (4) COPIES OF ALL SHOP DRAWINGS (EQUIPMENTAND FIXTURE SUBMITTALS), OPERATION AND MAINTENANCE MANUALSAND AS-BUILT (RECORD) DRAWINGS. ALL MANUALS SHALL INCLUDE AMAINTENANCE SCHEDULE FOR ALL REQUIRED EQUIPMENT (I.E. PUMPS,WATER FILTERS). ALL MANUALS SHALL BE COMPILED IN ACCORDANCEWITH THE PROVISIONS OF DIVISION 1 OF THESE SPECIFICATIONS.
1.3 QUALITY ASSURANCE: USE ADEQUATE NUMBERS OF SKILLEDWORKERS WHO ARE THOROUGHLY TRAINED AND EXPERIENCED IN THENECESSARY CRAFTS AND WHO ARE COMPLETELY FAMILIAR WITH THESPECIFIED REQUIREMENTS AND THE METHODS NEEDED FOR PROPERPERFORMANCE OF THE WORK OF THIS SECTION.
CODES AND REGULATIONS: IN ADDITION TO COMPLYING WITH THESPECIFIED REQUIREMENTS, COMPLY WITH THE PERTINENTREGULATIONS OF GOVERNMENTAL AGENCIES HAVING JURISDICTION;INCLUDING THE 2012 INTERNATIONAL BUILDING, PLUMBING, FUELGAS, AND ENERGY CONSERVATION CODES; AND ANY AMMENDMENTSTO ABOVE CODES REQUIRED BY THE LOCAL AUTHORITIES. IN THEEVENT OF CONFLICT BETWEEN OR AMONG SPECIFIED REQUIREMENTSAND PERTINENT REGULATIONS, THE MORE STRINGENT REQUIREMENTWILL GOVERN WHEN SO DIRECTED BY THE ARCHITECT.
1.4 DELIVERY, STORAGE, AND HANDLING: COMPLY WITH THEPERTINENT PROVISIONS OF DIVISION 1.
1.5 GENERAL REQUIREMENTS: WHERE REQUIRED BY CODE, ALL WORKMUST BE INSPECTED AND APPROVED BY LOCAL AUTHORITIES. PRIOR TOFINAL ACCEPTANCE, FURNISH THE ARCHITECT/OWNER WITHCERTIFICATES OF INSPECTION AND APPROVALS BY LOCAL AUTHORITIES.BEFORE ACCEPTANCE AND FINAL PAYMENT, DEMONSTRATE THAT ALLAPPARATUS ARE FUNCTIONING PROPERLY AND EFFICIENTLY. SYSTEM,MATERIAL, AND WORKMANSHIP SHALL BE GUARANTEED FOR A PERIODOF ONE YEAR AFTER THE COMPLETION AND ACCEPTANCE. REPLACEALL DEFECTIVE WORKMANSHIP, EQUIPMENT AND MATERIALS WITHOUTADDITIONAL CHARGES, INCLUDING REFRIGERANT THAT IS LOSTDURING RELATED REPAIRS.
PART 2 - PRODUCTS
2.1 PIPE SCHEDULE:
DRAIN, WASTE, AND VENT SYSTEM: PVC PIPE, ASTM D 2665, SOLID-WALLDRAIN, WASTE AND VENT PIPING WITH PVC SOCKET FITTINGSCOMPLYING WITH ASTM D 2665, SOCKET TYPE, MADE TO ASTM D3311, DRAIN, WASTE, AND VENT PATTERNS. SCHEDULE 40 CAST IRONPIPING SHALL BE PROVIDED FOR ALL WASTE AND VENT PIPING WITH ARETURN OR SUPPLY AIR PLENUM.
WATER PIPING: ABOVE GROUND: PROVIDE TYPE "L" HARD DRAWNCOPPER WITH WROUGHT COPPER FITTINGS JOINED WITH LEAD FREESOLDER. BELOW GROUND: PROVIDE TYPE "K" SOFT ANNEALED COPPERWITH NO SOLDERED JOINTS.
INDIRECT DRAINS: PROVIDE TYPE "L" COPPER WITH WROUGHT COPPERFITTINGS JOINED WITH 95/5 TIN-ANTIMONY OR LEAD FREE SOLDER.WHEN SIZE ALLOWS PROVIDE DWV TYPE FITTINGS. PROVIDE LINES FULLSIZE OF ANY EQUIPMENT CONNECTIONS.
NATURAL GAS PIPING: PROVIDE SHUT-OFF VALVE DOWNSTREAM OFAND AS CLOSE AS PRACTICAL TO EACH GAS METER. PROVIDESCHEDULE 40 BLACK IRON PIPE WITH MALLEABLE IRON FITTINGS. PIPING2" AND UNDER SHALL HAVE SCREWED FITTINGS, 2-1/2" AND LARGER,AND ALL CONCEALED GAS PIPING SHALL BE WELDED. VALVES UP TO 2"SHALL BE BRASS. PROVIDE DIRT LEG, SHUT-OFF VALVE, PRESSUREREDUCING VALVE, AND UNION AT EACH APPLIANCE CONNECTION.UNDERGROUND PIPING SHALL BE PROTECTED AGAINST CORROSION.
STORM DRAINAGE PIPING: HUBLESS CAST IRON SOIL PIPE. PITCHHORIZONTAL LEADERS AT 1/8" PER FOOT FALL IN DIRECTION OF FLOWUNLESS OTHERWISE NOTED.
2.2 MATERIALS: CAST IRON SOIL PIPE AND FITTINGS:
FOR COPPER PIPING, PROVIDE WROUGHT COPPER OR DWV TYPEFITTINGS FOR THE APPROPRIATE PIPING SYSTEM. ALL EXPOSED PIPING INKITCHENS AND OTHER FOOD PREPARATION AREAS SHALL BE COPPER.
2.3 VALVES: GATE VALVES: EQUAL TO WATTS GV SERIES, BRONZE,200-PSI WOG. GLOBE VALVES: EQUAL TO WATTS GLV SERIES, BRONZE,200-PSI WOG. BALL VALVES: EQUAL TO WATTS B-600 SERIES, STANDARDPORT, BRONZE. 1/4" - 2" VALVES SHALL BE 600 PSI WOG. 2-1/2" - 4"SHALL BE 400 PSI WOG.
2.4 FLASHING: WHERE PIPES OF THIS SECTION PASS THROUGH THEROOF, FLASH WITH SEMCO #1100-4 SEAMLESS 4 LB. FLASHING, WITHSTEEL REINFORCED "VARI-PITCH" BOOT AND CAST IRON COUNTERFLASHING SLEEVE.
2.5 PIPE HANGERS:
WATER PIPING: PROVIDE FEE AND MASON #212 SPLIT RING HANGERSWITH SUPPORTING RODS. PROVIDE SEMCO "TRISOLATORS".
SOIL AND WASTE PIPING: PROVIDE FEE AND MASON #212 ADJUSTABLERING HANGERS WITH SUPPORTING RODS. USE FEE AND MASON #212RISER CLAMPS AS REQUIRED.
2.6 CLEANOUTS: ZURN Z-1400 "LEVEL-TROL" ADJUSTABLE FLOORCLEANOUT, DURA-COATED CAST IRON BODY, WITH GAS ANDWATERTIGHT ABS TAPERED THREAD PLUG, AND ROUND SCORIATEDSECURED TOP ADJUSTABLE TO THE FINISHED FLOOR. FINISHEDFLOORS: PROVIDE ZURN ZN-1400 WITH APPROPRIATE SUFFIX FORFLOOR FINISH. FLOORS WITH WATERPROOFING MEMBRANE: PROVIDE"FLUSH-WITH-FLOOR" TYPE CLEANOUTS, WITH ADJUSTABLEWATERTIGHT COVERS AND INTEGRAL ANCHORING FLANGE WITHCLAMPING COLLAR. FINISHED WALLS: PROVIDE ZURN ZS-1469 WITHSTAINLESS STEEL ACCESS PLATE AND SCREW.
2.7 TRAPS: FOR LAVATORIES AND SINKS, EXCEPT SERVICE SINKS,PROVIDE LOS ANGELES PATTERN CAST BRASS TRAPS WITH BRASS NUTS.
2.8 WATER HAMMER ARRESTORS: PROVIDE WHERE REQUIRED BY CODE.
2.9 FIXTURES AND EQUIPMENT: PROVIDE PLUMBING FIXTURES, TRIM,AND EQUIPMENT AS INDICATED ON THE PLUMBING PLANS.
2.10 INSULATION: INSULATE HOT, COLD AND RECIRCULATED HOTWATER PIPING WITH 1-IN. THICK FIBERGLASS INSULATION WITH PLENUMRATED JACKET. RUNOUTS UP TO 12 FEET SHALL HAVE 1/2-IN. THICKINSULATION. INSULATION SHALL BE EQUAL TO JOHNS MANVILLEMICO-LOK, WITH A MAXIMUM CONDUCTIVITY OF 0.27 BTU PER IN/HR *SF * degF. COLD WATER PIPING INSULATION SHALL HAVE VAPORBARRIER. AT ALL HANGER AND SUPPORT LOCATIONS, PROVIDE 8-IN.LONG, 20 GAUGE GALVANIZED IRON INSULATION GUARDS.INSULATION AT THESE LOCATIONS SHALL BE RIGID.
PROTECT EXPOSED PIPING FOR ALL ADA ACCESSIBLE FIXTURES WITHINSULATION EQUAL TO TRU BRO.
STORM DRAINAGE PIPING SHALL BE INSULATED WITH 1-1/2" THICKFIBERGLASS INSULATION WITH VAPOR BARRIER AND PLENUM RATED PVCJACKET. INSULATION SYSTEM SHALL BE EQUAL TO JOHNS MANVILLEMICRO-LOK, WITH ZESTON PVC JACKETING, 30 MIL THICKNESS. VAPORBARRIER SHALL BE PROVIDED WITH A MASTIC COMPATIBLE WITH PVC,AND TWO LAYERS OF HI-LO TEMP INSULATION INSERTS SHALL BEUTILIZED TO MAINTAIN THE INTEGRITY OF THE VAPOR BARRIER. INSERTSAND JACKET SHALL MEET ASTM E84 FOR MAXIMUM FLAME SPREAD ANDSMOKE DEVELOPED RATING OF 25/50. EXPOSED VERTICAL STORMDRAINAGE PIPING SHALL NOT BE INSULATED.
2.11 SLEEVES: WHERE PIPES PASS THROUGH CONCRETE, MASONRY, ORSTUD WALLS, OR PASS THROUGH CEILINGS, PROVIDE "SPERZEL"RUSTPROOF "CRETE-SLEEVE" OF THE SIZE REQUIRED. WHERE PIPES PASSTHROUGH FIRE RATED PARTITIONS AS DESIGNATED ON THEARCHITECTURAL PLANS, PROVIDE FIRE SEALS AROUND PIPES, WHICH AREEITHER UL LISTED OR FM APPROVED.
2.12 OTHER MATERIALS: PROVIDE OTHER MATERIALS NOT SPECIFICALLYDESCRIBED BUT REQUIRED FOR A COMPLETE AND PROPERINSTALLATION, AS SELECTED BY THE CONTRACTOR SUBJECT TO THEAPPROVAL OF THE ARCHITECT.
PART 3 - EXECUTION
3.1 SURFACE CONDITIONS: EXAMINE THE AREAS AND CONDITIONSUNDER WHICH WORK OF THIS SECTION WILL BE PERFORMED.CORRECT CONDITIONS DETRIMENTAL TO TIMELY AND PROPERCOMPLETION OF THE WORK. DO NOT PROCEED UNTILUNSATISFACTORY CONDITIONS ARE CORRECTED.
3.2 INSTALLATION OF PIPING AND EQUIPMENT:
PROCEED AS RAPIDLY AS THE BUILDING CONSTRUCTION WILL PERMIT.THOROUGHLY CLEAN ITEMS BEFORE INSTALLATION. CAP PIPEOPENINGS TO EXCLUDE DIRT UNTIL FIXTURES ARE INSTALLED AND FINALCONNECTIONS HAVE BEEN MADE. CUT PIPE ACCURATELY, AND WORKINTO PLACE WITHOUT SPRINGING OR FORCING, PROPERLY CLEARINGWINDOWS, DOORS, AND OTHER OPENINGS. EXCESSIVE CUTTING OROTHER WEAKENING OF THE BUILDING WILL NOT BE PERMITTED. SHOWNO TOOL MARKS OR THREADS ON EXPOSED PLATED, POLISHED, ORENAMELED CONNECTIONS FROM FIXTURES. TAPE ALL FINISHEDSURFACES TO PREVENT DAMAGE DURING CONSTRUCTION. MAKECHANGES IN DIRECTION WITH FITTINGS; MAKE CHANGES IN MAINSIZES WITH ECCENTRIC REDUCING FITTINGS. UNLESS OTHERWISENOTED, INSTALL WATER SUPPLY AND RETURN PIPING WITH FLAT SIDE OFECCENTRIC FITTINGS FACING UP. RUN HORIZONTAL SANITARY PIPINGAT A UNIFORM GRADE OF 1/4" PER FOOT, UNLESS OTHERWISE NOTED.RUN HORIZONTAL WATER PIPING WITH AN ADEQUATE PITCH UPWARDSIN DIRECTION OF FLOW TO ALLOW COMPLETE DRAINAGE. PROVIDESUFFICIENT SWING JOINTS, BALL JOINTS, EXPANSION LOOPS, ANDDEVICES NECESSARY FOR A FLEXIBLE PIPING SYSTEM, EVEN IF NOTSPECIFICALLY SHOWN ON THE DRAWINGS. SECURELY BOLT ALLEQUIPMENT, ISOLATORS, HANGERS, AND SIMILAR ITEMS IN PLACE.SUPPORT EACH ITEM INDEPENDENTLY FROM THE STRUCTURE. DO NOTUSE WIRE FOR HANGING OR STRAPPING PIPES. PROVIDE COMPLETEDIELECTRIC ISOLATION BETWEEN FERROUS AND NONFERROUS METALS.FOR INSULATED PIPE, PROVIDE SLEEVES OF ADEQUATE SIZE TOACCOMMODATE THE FULL THICKNESS OF PIPE COVERING, WITHCLEARANCE FOR PACKING AND CAULKING. CAULK THE SPACEBETWEEN SLEEVE AND PIPE OR PIPE COVERING, USING ANON-COMBUSTIBLE, PERMANENTLY PLASTIC, WATERPROOF,NON-STAINING COMPOUND WHICH LEAVES A SMOOTH FINISHEDAPPEARANCE, OR PACK WITH NON-COMBUSTIBLE, NON-ASBESTOSCOTTON, ROPE, OR FIBERGLASS TO WITHIN 1/2" OF BOTH WALLFACES, AND PROVIDE THE WATERPROOF COMPOUND DESCRIBEDABOVE.
3.3 FINISH AND ESCUTCHEONS: SMOOTH UP ROUGH EDGES AROUNDSLEEVES WITH PLASTER OR SPACKLING COMPOUND. PROVIDE 1" WIDECHROME OR NICKEL PLATED ESCUTCHEONS ON ALL PIPES EXPOSED TOVIEW WHERE PASSING THROUGH WALLS, FLOORS, PARTITIONS,CEILINGS, OR SIMILAR LOCATIONS. SIZE THE ESCUTCHEONS TO FIT PIPEAND COVERING. HOLD ESCUTCHEONS IN PLACE WITH SET SCREW.
3.4 CLEANOUTS: SECURE THE ARCHITECT'S APPROVAL OF LOCATIONSFOR CLEANOUTS IN FINISHED AREAS PRIOR TO INSTALLATION. PROVIDECLEANOUTS OF SAME NOMINAL SIZE AS THE PIPES THEY SERVE; EXCEPTWHERE CLEANOUTS ARE REQUIRED IN PIPES LARGER THAN 4", PROVIDE4" CLEANOUTS. MAKE CLEANOUTS ACCESSIBLE. AFTER PRESSURE TESTSARE MADE AND APPROVED, THOROUGHLY GRAPHITE THE CLEANOUTTHREADS. PROVIDE CLEANOUTS IN ALL LOCATIONS (NOT NECESSARILYINDICATED ON DRAWINGS) REQUIRED BY THE APPLICABLE CODES.
3.5 VALVES: PROVIDE VALVES IN DOMESTIC WATER SUPPLY SYSTEMS.LOCATE AND ARRANGE SO AS TO GIVE COMPLETE REGULATION OFFIXTURES. PROVIDE VALVES IN AT LEAST THE FOLLOWING LOCATIONS:IN BRANCHES AND/OR HEADERS OF WATER PIPING SERVING A GROUPOF FIXTURES; FOR SHUTOFF OF BRANCH MAINS; FOR FLUSHING ANDSTERILIZING THE SYSTEM; WHERE SHOWN ON THE DRAWINGS. LOCATEVALVES FOR EASY ACCESSIBILITY AND MAINTENANCE
3.6 WATER HAMMER ARRESTORS: PROVIDE WATER HAMMER ARRESTORSON HOT WATER LINES AND COLD WATER LINES. INSTALL IN UPRIGHTPOSITION AT ALL QUICK CLOSING VALVES, SOLENOIDS, ISOLATEDPLUMBING FIXTURES, AND SUPPLY HEADERS AT PLUMBING FIXTUREGROUPS. LOCATE AND SIZE IN ACCORDANCE WITH THE PLUMBINGAND DRAINAGE INSTITUTE STANDARD WH-201. INSTALL WATERHAMMER ARRESTORS BEHIND ACCESS PANELS.
3.7 BACKFLOW PREVENTION: PROTECT PLUMBING FIXTURES ANDFAUCETS AGAINST POSSIBLE BACK-SIPHONAGE. ARRANGE FORTESTING OF BACKFLOW DEVICES AS REQUIRED BY THEGOVERNMENTAL AGENCY HAVING JURISDICTION.
3.8 PLUMBING FIXTURE INSTALLATION: SET FIXTURES LEVEL AND INPROPER ALIGNMENT WITH RESPECT TO WALLS AND FLOORS AND WITHFIXTURES EQUALLY SPACED. PROVIDE SUPPLIES IN PROPER ALIGNMENTWITH FIXTURES AND WITH EACH OTHER. PROVIDE FLUSH VALVES INALIGNMENT WITH THE FIXTURE, WITHOUT VERTICAL OR HORIZONTALOFFSETS. GROUT WALL AND FLOOR MOUNTED FIXTURES WATERTIGHTWHERE THE FIXTURES ARE IN CONTACT WITH WALLS AND FLOORS.
3.9 DISINFECTION OF POTABLE WATER POTABLE WATER SYSTEMS SHALLBE PURGED OF DELETERIOUS MATTER AN DISINFECTED PRIOR TOUTILIZATION. THE METHOD TO BE FOLLOWED SHALL BE THATPRESCRIBED BY THE HEALTH AUTHORITY OR WATER PRUVEYOR HAVINGJURISDICTION.
3.10 OTHER TESTING AND ADJUSTING: PROVIDE PERSONNEL ANDEQUIPMENT, AND ARRANGE FOR AND PAY THE COSTS OF ALLREQUIRED TESTS AND INSPECTIONS REQUIRED BY GOVERNMENTALAGENCIES HAVING JURISDICTION. WHERE TESTS SHOW MATERIALS ORWORKMANSHIP TO BE DEFICIENT, REPLACE OR REPAIR AS NECESSARY,AND REPEAT THE TESTS UNTIL THE SPECIFIED STANDARDS AREACHIEVED. ADJUST THE SYSTEM TO OPTIMUM STANDARDS OFOPERATION.
EXISTING. VERIFY LOCATION, SIZE, ANDCAPACITY.
(E)
SANITARY SEWERSSSS SS
CLEANOUT TO GRADE
11. ELBOW DOWN2. PRV (PRESSURE REDU VL)G G
ABOVE FINISH FLOORAFF
FLOOR DRAIN
ROOF DRAIN
VENT THRU ROOFVTR
RD
FD
COTG
NATURAL GAS LINEG
BALANCE VALVE W/MEMORY
V V V
SYMBOL
BRONZE CHECK VALVE
BRONZE CONTROL VALVE
AGA LISTED GAS COCK
FEBCO 825Y OR EQUALBACKFLOW PREVENTER)
9"THERMOMETER ±1%
BRONZE UNION
RPBP (REDUCED PRESS
9.
7.
8.
5.
6.
3.
4.
DESCRIPTION
COLD WATER
HOT WATER
SANITARY VENTV
ABBREV.
HW
CW
SIDE T CONNECTION
BOTTOM T CONNECTION
TOP T CONNECTION
BRONZE STRAINER
SHOCK ABSORBER
ELBOW UPPIPE ANCHOR
CIRCUIT SETTER
MANUAL AIR VENTPRESSURE GAGE
16.
19.
17.18.
21.20.
12.
13.
15.
14.
3
15
BRONZE/STAINLESS BALL VALVE
VALVES, FITTINGS, ETC
11
1.
1312 14
1 2
19
END CAP10.
1716 18
4 5 6
2120
7 8 9 10
PLUMBING LEGEND
(E)SS
(E)GW
EXISTING SANITARY SEWER
EXISTING GREASE WASTE(E)GW
(E)SS
TOTAL DEVELOPED LENGTHTDL
CONNECT NEW TO EXISTING
Fixture Unit Calculator for Water DemandFixture
Bathroom groupKitchen sinkService sinkHose BibTotals:
Total @125%Note: Based upon the IPC Table E103.3
OccupancyPrivatePrivate
Offices, etc.
Type of Supply CTRLFlush tank
FaucetFaucet
WSFU3.61.435
Qty2112
Total7.21.43
1021.6
27
PLUMBING FIXTURE SCHEDULE
MARK(S)
WH-1
ET-1
WC-1
LW-1
FD-2
MS-1
BS-2
MXV
DESCRIPTION
WATER HEATER
EXPANSION TANK
WATER CLOSET / ADA
LAVATORY, WALL MOUNT
FLOOR DRAIN
MOP SINK
BREAK ROOM SINK
MIXING VALVE
MANUFACTURER / MODEL NO.
State Model PCE30 20LSA
State Model ETC-2X
American Standard, Cadet 2998.014
American Standard, Lucerne 0356.027
Zurn ZB-1400
Fiat model TTB 2424
Elkay GECR 2521
American Standard 605XTMV
CW
3/4"
3/4"
1/2"
1/2"
-
1/2"
1/2"
3/8"
HW
3/4"
-
1/2"
-
1/2"
1/2"
3/8"
WASTE
-
3"
1-1/2"
2"
2"
1-1/2"
VENT
-
2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
REMARKS
4.5 KW single element (208v/1ph), 30 gallon, 30-7/8"Ø
1.96 gallon, 150 PSIG, 210ºF rated, NSF bladder, 5 yr. warranty
Elongated bowl, 1/2"CW supply, ADA Compliant
ADA Compliant, three hole on 4" center, open grid drain, Cadet 8125F faucet, handicaptrap wrap, chrome plated P-trap w/cleanout, angle supplies w/stops, 1/2 GPM flow limiters,install Conbraco MVD temperature limiting device below sink.Deep seal trap, round top, medium duty grate. Install "waterless" trap primerequal to Proset trap guard with elastomeric memory material in all floordrains. Follow all Manufacturer instructions for installation of the trap guard.24" x 24" terrazzo neocorner floor mount sink,Fiat model 830AA utility faucet w/ vacuum breaker and pail hookdeep seal trap, acid-resist interior and grate, cast iron4-hole ADA compliant, p-trap with clean out,25 x 21 bowl, Delta model 2100 HDF faucet with wrist blades 1/2 hp waste king disposal, stainless steel sink3/8" compression connections, integral checks and 3/8" compression tee3/8" tempered water to HW supply of fixture.
1WH
ET1
DIELECTRIC UNION
ASME P&T RELIEF VALVE, PIPEFULL SIZE TO 2" AIR GAPOVER FLOOR DRAIN
MS
BALL VALVE
1"HW
1"CW
SCALE:P0.01 WATER HEATER DETAIL
NONESCALE:P0.02 MXV - MIXING VALVE
NONE P0.0PLUMBING
NOTES & SCHEDULES
Sheet:
Project Number:
4303 Brighton Blvd., Building #3Denver, Colorado 80216720-891-8703
General Contractor:
Owner:Cellular Sales9040 Executive Park DriveKnoxville, TN 37923Contact: Colby Smith
Structural Engineer:
MEP Engineer:
Number:
7/4/
2016
12:
56:4
2 P
M
kVA 16-077
Cel
lula
r Sal
es -
Sup
erio
r30
4 M
arsh
all R
d.S
uper
ior,
CO
Issued For: DatePERMIT 07.08.16
#
SCALE:P1.01 WATER & GAS PLAN
1/4" = 1'-0"
Conference Room106
Toilet108
Toilet107
Service105
Inventory102
Break104
Show Room101
Vestibule100
Corridor103
ProjectNorth
1
2
3
34"HW1"CW
34"HW1"CW
1"CW
34"HW34"CW
34"HW34"CW
1-1/2"(E)CW
GG
G
GGGGGGGGGGGGGG
G
GG
[A]
Nominal
Pipe Size "d"
1-1/2
1-1/4
1-1/4
Initial Gas Pressure =
Pressure Drop MAX =
Final Gas Pressure =
Specific Gravity =
Factor for visc, density and temp =
Viscosity of Gas=
(L)
ft length (L)105105105
ACTUAL METER Gas Pressure =
MAX Press Drop =
Local Barometric Pressure =
P1 =P1 - P2 =
P2 =S =
Cr =Z=
(D)
Minimum D1.4511.1141.114
6"WC =
0.5"WC =
PRESSURE AT END OF LINE = 5.5"WC =
INPUTS:12.20
0.21670.018112.400.60
0.60940.012
(Q)
MBH448224224
0.2167
0.0181
0.1987
PSIA
PSI =
PSI =
PSI =
SG
Description of piping section
GAS METER TO POINT [A]POINT [A] TO RT-1POINT [A] TO RT-2
PSI
PSI
PSI
Converted Pressures:
6.00
0.50
5.50
STP is 60oF and 14.7 psia or 101.325 kPA
(use 1.2462 for propane)
(use .008 for propane)
"WC Initial Pressure at GAS METER
"WC MAX Pressure Drop
"WC Final Pressure P2 at Appliance
SL =
5000f t=
1 PSI =
1 PSI =
1" WC =
CONVERSION DATA:
14.7
12.2
2.307
27.684
0.0361
PSIA
PSIA
ftWC
"WC
PSI
LW-1WC-1
LW-1 WC-1
MS-1
BS-1
P1.0PLUMBING
PLANS - WATER
Sheet:
Project Number:
4303 Brighton Blvd., Building #3Denver, Colorado 80216720-891-8703
General Contractor:
Owner:Cellular Sales9040 Executive Park DriveKnoxville, TN 37923Contact: Colby Smith
Structural Engineer:
MEP Engineer:
Number:
7/4/
2016
12:
56:4
2 P
M
kVA 16-077
Cel
lula
r Sal
es -
Sup
erio
r30
4 M
arsh
all R
d.S
uper
ior,
CO
Issued For: DatePERMIT 07.08.16
#
SCALE:P2.01 WASTE PLAN
1/4" = 1'-0"
Conference Room106
Toilet108
Toilet107
Service105
Inventory102
Break104
Show Room101
Vestibule100
Corridor103
ProjectNorth
(E)S
S(E
)SS
(E)S
S(E
)SS
(E)S
S
(E)SS (E)SS
SS
SS
SSSSSSSSSSSS
SSSSSS
1
2
2
SS
FD-1
FD-1LW-1WC-1
FD-1LW-1WC-1
MS-1
BS-1
(E)SS
(E)SS2
SS
SS
SS
SS
(E)SS
SSV
VV
V
V
V
V2
V
V
V V
V
V
V
V
V
V
V
V
V
3
1
SCALE:P2.02 WASTE ISOMETRIC
NONE
P2.0PLUMBING
PLANS - WASTE
Sheet:
Project Number:
4303 Brighton Blvd., Building #3Denver, Colorado 80216720-891-8703
General Contractor:
Owner:Cellular Sales9040 Executive Park DriveKnoxville, TN 37923Contact: Colby Smith
Structural Engineer:
MEP Engineer:
Number:
7/4/
2016
12:
56:4
2 P
M
kVA 16-077
Cel
lula
r Sal
es -
Sup
erio
r30
4 M
arsh
all R
d.S
uper
ior,
CO
Issued For: DatePERMIT 07.08.16
T
APANEL
GRADE LEVEL
PANEL
PAD MOUNTED UTILITY300kVA TRANSFORMER208/120V, 3-PHASE, 4W
200/4150/4
3[4-350kcmil, 3-1/2" C]
>800G
800A JJN800A/3P
E0.01 ONE LINE DIAGRAM
NTSSCALE:
FIRE ALARM SYSTEM NOTESFIRE ALARM SYSTEM IS TO BE DESIGN/BUILD BY THECONTRACTOR.
PANELC
400A/3P
M
400/4
UTILITY C.T.& METER
TTB TELEPHONE TERMINAL BOARD
#
D
EMERGENCY FIXTURE - SHADED
SINGLE POLE SWITCH, OR #-POLE
or COMBO EXIT - SEE SCHEDULE
EXIT SIGN - SHADED INDICATES FACE
DIMMER SWITCH
AFF ABOVE FINISH FLOOR
GROUNDED DUPLEX RECEPTACLE FLOOR/CEILING MOUNTED TELEPHONE OUTLET
X-##
J
TO
T
K
S DUCT FIRE DETECTOR
ABBREVIATIONS
EWC
RECESSED FLUORESCENT LIGHT FIXTURE
SURFACE MOUNTED FLUORESCENT FIXTURE
WALLWASHER or ADJUSTABLE DOWNLIGHT
CEILING FIXTURE
CCTE.C.
ACWP
EFGFI
APPEAR NEXT TO DEVICES)(ARROWS NOT USED IF CIRCUIT NUMBERS CIRCUIT '##' HOMERUN TO PANEL 'X'
PORCELAIN LAMP HOLDER
TRANSFORMER
S
ABOVE COUNTER - VERIFY HEIGHT
GROUND FAULT INTERRUPTING
CIRCUITELECTRICAL CONTRACTOR
WEATHER PROOF
EXHAUST FANELECTRIC WATER COOLER
SPEAKER
FAA
WALL MOUNTED JUNCTION BOX
ELECTRICAL PANEL BOARD
THERMAL OVERLOAD SWITCH
EQUIPMENT DISCONNECT SWITCH
EQUIPMENT FUSED DISCONNECT SWITCH
J
S
SPECIAL PURPOSE RECEPTACLE
FLOOR/CEILING MOUNTED RECEPTACLE
GROUNDED QUADRAPLEX RECEPTACLE
JUNCTION BOX
FACP
FIRE ALARM REMOTE ANNUNICATOR
S-SMOKE, T-HEAT DETECTOR
PANEL
TELEPHONE/DATA OUTLET, PROJECT STANDARD
FIRE ALARM PANEL
TELEPHONE OUTLET
DATA OUTLET
POWER AND LIGHTING
ELECTRICAL LEGEND
LOW VOLTAGE SYSTEMS
GROUNDED SWITCHED DUPLEX RECEPTACLE
GROUNDED SPLIT-WIRED RECEPTACLE FLOOR/CEILING MOUNTED DATA OUTLET
TELEPHONE TERMINAL BOARD
REFERENCE SYMBOLS
FEEDER - SEE SCHEDULE
KEYED NOTE
XFMR
kVA
TRANSFORMER WITH GROUNDING ANDOVERCURRENT DEVICES SEETRANSFORMER SCHEDULE
#/W
XX
#
AG ABOVE COUNTER GFI - VERIFY HEIGHT
T
##
EQUIPMENT - SEE SCHEDULE#
BATTERY PACK EMERGENCY LIGHT
(ER)
(E)
EXISTING TO BE RELOCATED
EXISTING TO REMAIN
(R) RELOCATE/RELOCATED LOCATION
(EX) EXISTING TO BE REMOVED
AHJ AUTHORITY HAVING JURISDICTION
AFI ARC FAULT INTERRUPTING
NOTE: NOT ALL ITEMS APPEAR ON DRAWINGS. SYMBOLS MAY DIFFER FROM EXISTINGAND DEMO WORK OR DEVICES REFERENCED FROM DRAWINGS BY OTHERS.
CATV/MONITOR A/V OUTLET
GENERAL PROJECT NOTESNOTE: SEE ARCHITECTURAL DRAWINGS FOR ADDITIONAL CONSTRUCTION REQUIREMENTS
1. THE CONTRACTOR SHALL PROVIDE ALL LABOR AND MATERIAL NECESSARY FOR A COMPLETE,OPERATIONAL AND PROPERLY FUNCTIONING ELECTRICAL SYSTEM
2. MATERIALS AND INSTALLATION SHALL COMPLY WITH CODES, LAWS AND ORDINANCES OF FEDERAL,STATE AND LOCAL GOVERNING BODIES HAVING JURISDICTION.
3. MATERIALS AND EQUIPMENT SHALL BE LISTED AND/OR LABELED BY U.L., ETL, CSA OR ANOTHERRECOGNIZED TESTING LAB. ALL MATERIAL, EQUIPMENT, WIRING DEVICES, ETC. SHALL BE NEW, UNLESSSPECIFICALLY INDICATED AS EXISTING TO BE REUSED.
4. THE CONTRACTOR SHALL PREPARE AND SUBMIT TO GOVERNMENTAL AGENCIES AND UTILITYCOMPANIES SHOP DRAWINGS REQUIRED BY THESE AGENCIES FOR APPROVAL. THE CONTRACTOR SHALLSECURE AND PAY FOR ALL PERMITS, GOVERNMENTAL FEES, TAXES AND LICENSES NECESSARY FOR THEPROPER EXECUTION AND COMPLETION OF THE ELECTRICAL WORK. THIS CONTRACTOR SHALL SECUREAND PAY ALL FEES AND PERMITS PERTAINING TO THIS CONTRACT, SHALL BE RESPONSIBLE FOR WORKER'SIDENTIFICATION AND BADGING, SAFETY, AND LIABILITY INSURANCE. PROVIDE BARRICADES, WARNINGSIGNS, AND TRASH REMOVAL FOR THE SAFETY OF THE WORKERS UNDER THIS CONTRACTOR'S EMPLOY.
5. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER/OWNER OF ANY MATERIALS ORAPPARATUS BELIEVED TO BE INADEQUATE, UNSUITABLE, IN VIOLATION OF LAWS, ORDINANCES, RULESOR REGULATIONS OF AUTHORITIES HAVING JURISDICTION.
6. THE CONTRACTOR SHALL PREPARE THE DOCUMENTS, INCLUDING DRAWINGS, REQUIRED TO OBTAINAPPROVAL OF THE EQUIPMENT AND LOCATIONS OF THE DEVICES THAT COMPRISE THE BUILDING FIREALARM LIFE SAFETY SYSTEM. THE DRAWINGS AND CUT SHEETS SHALL BE PROVIDED TO A PROFESSIONALENGINEER FOR REVIEW AND APPROVAL. THE APPROVED DRAWINGS WILL BE STAMPED, SIGNED ANDRETURNED TO E.C. TO SUBMIT TO THE BUILDING DEPARTMENT.
7. THE CONTRACTOR SHALL CAREFULLY EXAMINE THE CONTRACT DOCUMENTS, VISIT THE SITE, ANDTHOROUGHLY BECOME FAMILIAR WITH THE BUILDING STANDARDS, LOCAL JURISDICTIONAL CODESAND REQUIREMENTS, AND LOCAL CONDITIONS RELATING TO THE WORK. FAILURE TO DO SO WILLNOT RELIEVE THE CONTRACTOR OF THE OBLIGATIONS OF THE CONTRACT. SUBMISSION OF PROPOSALIN CONNECTION WITH THIS WORK SHALL IMPLY THAT THE BIDDER HAS EXAMINED THE JOB SITE. NOEXTRA CHARGE WILL BE ALLOWED FOR CHANGES AS A RESULT FROM FAILURE TO EXAMINE THE JOB SITE.
8. THE CONTRACTOR SHALL PROVIDE TEMPORARY POWER AND WIRING FOR THE PERFORMANCE OF ALLTRADES, FOR THE ENTIRE PERIOD OF CONSTRUCTION AND SHALL REMOVE ALL TEMPORARY WIRING ATTHE COMPLETION OF CONSTRUCTION.
9. THE EXISTING POWER, SIGNAL AND COMMUNICATION SYSTEMS ARE TO REMAIN IN SERVICE TO PROVIDEFOR THE OWNER'S FUNCTION. SHOULD IT BECOME NECESSARY TO SHUT-DOWN ANY SYSTEM ORPORTION OF A SYSTEM, APPROVAL IN WRITING MUST BE OBTAINED FROM THE OWNER AND SHALLONLY APPLY FOR THE PERIOD AND TIME AGREED UPON. THE BID IS TO INCLUDE THE COST OF ANYTEMPORARY WIRING AND PREMIUM TIME REQUIRED FOR THE SHUTDOWN.
10. ALL MATERIALS AND EQUIPMENT SHALL BE ERECTED, INSTALLED, CONNECTED, CLEANED, ADJUSTED,TESTED, CONDITIONED, AND PLACED IN SERVICE IN ACCORDANCE WITH THE MANUFACTURER'SDIRECTIONS AND RECOMMENDATIONS.
11. ALL CUTTING, DRILLING AND PATCHING OF MASONRY, STEEL OR IRON WORK BELONGING TO THEBUILDING MUST BE DONE BY THIS CONTRACTOR IN ORDER THAT HIS WORK MAY BE PROPERLYINSTALLED, BUT UNDER NO CONDITIONS MAY STRUCTURAL WORK BE CUT, EXCEPT AT THE DIRECTIONOF THE ARCHITECT-DESIGNER OR THEIR REPRESENTATIVE.
12. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND MOUNTING HEIGHTS OFELECTRICAL FIXTURES AND ELECTRICAL DEVICES. MOUNTING HEIGHTS SHALL CONFORM TOADA/ICC/ANSI STANDARDS.
13. ALL WORK REQUIRED FOR THE INSTALLATION AS SHOWN ON DRAWINGS INCLUDING LABOR,EQUIPMENT AND MATERIALS SHALL BE IN STRICT COMPLIANCE WITH THE BUILDING STANDARDS.
14. PROVIDE COMPLETE METAL RACEWAY SYSTEMS AND ENCLOSURES FOR ALL WIRING THROUGHOUT THEEXTENT OF THE REQUIRED SYSTEM.
15. ALL TELE/ DATA BOXES SHALL BE PROVIDED WITH A 1/2” CONDUIT AND BUSHING WITH PULL STRINGRUN 6” ABOVE FINISHED CEILING OR CEILING GRID. ELECTRICAL METALLIC TUBING (EMT) SHALL BE USEDFOR ALL WALL OUTLETS & TELEPHONE WIRING RUNNING BELOW RAISED FLOOR OR ABOVE HARDCEILINGS.
16. ALL RECEPTACLES NOTED AS ISOLATED GROUND (IG) OR DEDICATED OR CIRCUITED AS DEDICATEDSHALL BE PROVIDED WITH A DEDICATED GROUND AND NEUTRAL. ALL RECEPTACLES IN BATHROOMS,KITCHENS, ROOFTOPS, OUTDOORS, AND WITHIN 6FT. OF A SINK SHALL BE GFCI (OR SERVED BY A GFICIRCUIT BREAKER) PER NEC 210.8(B). THE E.C. SHALL PROVIDE GFCI OUTLETS (OR CIRCUIT BREAKERS) INALL LOCATIONS REQUIRED BY THE NEC. ALL RECEPTACLES IN DWELLING UNITS, GUEST ROOMS, ANDCHILD CARE FACILITIES (AS SPECIFIED BY ARTICLE 406 OF THE 2014 NEC) SHALL BE LISTED ASTAMPER-RESISTANT RECEPTACLES.
17. MINIMUM CONDUIT SIZE SHALL BE 3/4" UNLESS OTHERWISE INDICATED. CONDUITS LARGER THAN 2"DIAMETER OR CONDUITS OF ANY SIZE ROUTED OUTDOORS SHALL BE INTERMEDIATE METAL CONDUIT(IMC
18. FLEXIBLE CONDUIT CONNECTIONS TO RECESSED LIGHTING FIXTURES SHALL BE MADE WITH FLEXIBLESTEEL CONDUIT, 3/8 INCH MINIMUM.
19. FINAL CONNECTIONS TO MOTORS SHALL BE MADE WITH LIQUID TIGHT FLEXIBLE STEEL CONDUIT, 1/2INCH MINIMUM.
20. WIRE NO. 8 AND SMALLER INSTALLED IN DRY LOCATIONS SHALL BE TYPE THWN OR THHNTHERMOPLASTIC 600V INSULATED COPPER CONDUCTORS. NO WIRE SMALLER THAN NO.12 SHALL BEUSED FOR LIGHTING OR POWER WIRING. WIRE NO. 8 AND LARGER SHALL BE STRANDED. ALLCONDUCTORS INSTALLED IN EXTERIOR OR WET LOCATIONS SHALL BE TYPE THWN 600V INSULATEDCOPPER CONDUCTORS.
21. ALL NEW CIRCUIT BREAKERS FOR NEW OR EXISTING PANELBOARDS SHALL MATCH EXISTING OR NEWBUILDING STANDARD PANELBOARD MANUFACTURER AND BREAKER TYPE. THE CONTRACTOR SHALLPROVIDE NEW ACCURATE AND DETAILED TYPE WRITTEN PANEL DIRECTORIES PER NEC 408.4 FOR ALLNEW OR MODIFIED PANELS. NUMBERED CIRCUITS ARE FOR CONVENIENCE OF DESIGN ONLY. E.C. TOFIELD VERIFY ACTUAL CIRCUIT NUMBERS USED AND CORRECTLY INDICATE ON "AS-BUILT" DRAWINGS.THE E.C. SHALL REMOVE ALL ABANDONED CIRCUITS.
22. PROVIDE #10 FOR BRANCH CIRCUITS OVER 75' AT 120V AND OVER 150' AT 277V. E.C. TO FIELD VERIFYBRANCH CIRCUIT LENGTHS AND SIZE CONDUCTORS FOR VOLTAGE DROP.
23. EACH SWITCH, LIGHT, RECEPTACLE AND ALL OTHER DEVICES SHALL BE PROVIDED AND INSTALLED WITH AGALVANIZED OR SHERARDIZED PRESSED STEEL JUNCTION BOX OF NOT LESS THAN NO. 14 U.S. GAUGESTEEL. CONDUITS SHALL BE FASTENED WITH LOCKNUTS AND BUSHINGS AND ALL UNUSED KNOCKOUTSMUST BE LEFT SEALED. THERE MUST BE SUFFICIENT ROOM FOR WIRES AND BUSHINGS AND DEEP BOXESSHALL BE INSTALLED WHERE REQUIRED. BOXES SHALL BE SECURELY AND ADEQUATELY SUPPORTED.
24. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL SPECIAL OUTLET BOXES THAT MAY BE REQUIRED TOENCLOSE RECEPTACLES.
25. IN SUSPENDED CEILINGS SUPPORT CONDUIT AND JUNCTION BOXES DIRECT FROM THE STRUCTURALSLAB, DECK, OR FRAMING PROVIDED FOR THAT PURPOSE. LIGHTING BRANCH CIRCUIT CONDUITSSHALL NOT BE CLIPPED TO THE CEILING SUPPORT WIRES OR SPLINE UNLESS THE CEILING SYSTEM HASBEEN SPECIFICALLY DESIGNED FOR THAT PURPOSE.
26. PROVIDE LOCAL DISCONNECT SWITCHES FOR ALL MOTORS (PLENUM APPROVED WHERE REQUIRED).
27. THE E.C. SHALL INCLUDE IN HIS COST THE REMOVAL OF ALL EXISTING ELECTRICAL DEVICES, CONDUITS,FIXTURES AND EQUIPMENT THAT IS NOT TO BE REUSED DISCARD ALL EQUIPMENT AS REQUIRED. E.C.SHALL BE RESPONSIBLE FOR DISCONNECTING PRIMARY SERVICE AND TEMPORARY POWER.
28. PROVIDE WARRANTY GUARANTEED FOR A PERIOD OF ONE YEAR AFTER COMPLETION ANDACCEPTANCE. REPLACE ALL DEFECTIVE WORKMANSHIP, EQUIPMENT AND MATERIALS WITHOUTADDITIONAL CHARGES.
29. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFEKEEPING OF HIS/HER OWN PROPERTY ON THEJOB SITE. THE OWNER OR TENANT ASSUMES NO RESPONSIBILITY FOR PROTECTION OF THISCONTRACTOR'S PROPERTY AGAINST FIRE, THEFT, OR ENVIRONMENTAL CONDITIONS.
30. WHERE CONDUIT, CABLES, DUCTWORK OR PIPING PASSES THROUGH FIRE RATED FLOORS, WALLS, ORPARTITIONS, THE SLEEVES SHALL BE COMPLETELY SEALED WITH A FIRE STOP MATERIAL THAT IS U.L. LISTED(EQUAL TO DOW CORNING) AND ACCEPTED BY THE BUILDING DEPARTMENT AND FIRE DEPARTMENT ASBEING SUITABLE FOR THE SERVICE. THIS MATERIAL SHALL BE INSTALLED IN ACCORDANCE WITH THEMANUFACTURER'S PUBLISHED INSTRUCTIONS IN ORDER TO MAINTAIN THE FIRE RATING OF THEPENETRATED WALL, FLOOR, OR PARTITION. INSTALLATION SHALL BE A THROUGH-PENETRATION FIRESTOPSYSTEM INSTALLED AS TESTED IN ACCORDANCE WITH ASTM AND UL . THE FIRE RATING SHALL MATCHTHE RATING OF THE BARRIER BEING PENETRATED.
31. SUBMIT SIX (6) SETS OF SHOP DRAWINGS, CONTROL DIAGRAMS, AND EQUIPMENT CUTS TO THEENGINEER FOR APPROVAL PRIOR TO STARTING RELATED WORK. SHOP DRAWINGS SHALL INCLUDEMANUFACTURER'S NAMES, CATALOG NUMBERS, CUTS, DIAGRAMS AND OTHER SUCH DESCRIPTIVE DATAAS MAY BE REQUIRED TO IDENTIFY AND REVIEW THE EQUIPMENT. SUBMITTALS SHALL BE IN LOGICALGROUPS, PARTIAL SUBMITTALS WILL NOT BE REVIEWED.
32. UPON COMPLETION OF CONSTRUCTION, SUPPLY THE ENGINEER WITH ONE COMPLETE SET OF FULLSIZE AS-BUILT DRAWINGS. PROVIDE THE OWNER WITH THREE (3) SETS OF OPERATION ANDMAINTENANCE MANUALS FOR EACH TYPE OF EQUIPMENT INSTALLED.
33. THIS CONTRACTOR SHALL ASSUME ALL ADDED EXPENSES TO ALL TRADES ASSOCIATED WITH THEINSTALLATION OF SUBMITTED AND APPROVED ALTERNATE EQUIPMENT.
34. THE CONTRACTOR SHALL COORDINATE THE LAYOUT OF THE FIRE ROOM WITH ALL OTHER DISCIPLINES,ESPECIALLY THE FIRE ALARM AND FIRE PROTECTION DESIGN-BUILD CONTRACTORS PRIOR TO ANYWORK.
35. IF ANY CHANGES ARE MADE TO ACCOMMODATE FIELD CONDITIONS NOTIFY THE ENGINEERIMMEDIATELY OF WHAT THE CHANGES WERE, THE REASON FOR THE CHANGES, AND THE COSTIMPACTS.
MAIN DISTRIBUTION PANEL "DP"120/208V, 3P, 4W, RECESSED, 42 kAIC
NG
Feeder Schedule - Cu3000/W2000/W1600/W1200/W1000/W800/W750/W600/W500/W400/W350/W300/W250/W225/W200/W175/W150/W125/W110/W100/W90/W80/W70/W60/W50/W40/W30/W20/W
This table indicates minimum conductor size for feedersof the ampacity indicated where #/W indicates theampacity/ numbers of wire. A #S/W indicates no ground.Service Ground Table150G200G300G500G800G>800G
8[W-500kcmil, 3/0G, 3-1/2"C]6[W-400kcmil, 3/0G, 3"C]5[W-400kcmil, 3/0G, 3"C]4[W-350kcmil, 3/0G, 3"C]3[W-400kcmil, 2/0G, 3"C]3[W-300kcmil, 1/0G, 3"C]3[W-250kcmil, 1/0G, 3"C]2[W-350kcmil, #1G, 3"C]2[W-250kcmil, #2G, 3"C]2[W-3/0, #3G, 2"C]2[W-2/0, #3G, 2"C]W-350kcmil, #4G, 3"CW-250kcmil, #4G, 3"CW-4/0, #4G, 2"CW-3/0, #6G, 2"CW-2/0, #6G, 2"CW-1/0, #6G, 2"CW-1/0, #6G, 2"CW#1, #6G, 1-1/2"CW#1, #6G, 1-1/2"CW#2, #8G, 1-1/4"CW#3, #8G, 1-1/4"CW#4, #8G, 1-1/4"CW#4, #8G, 1-1/4"CW#6, #10G, 1"CW#8, #10G, 1" CW#10, #10G, 3/4"CW#12, #12G, 3/4"C
#6#4#21/02/03/0
Equipment Ground Table20EG60EG100EG200EG300EG400EG
#12#10#8#6#4#3
Ampacities are based on NEC table 310.15(B)(16)utilizing the 60 degree column up to 100 Amps and the75 degree column above 100 Amps Service groundconductor sizes are per NEC table 250.66 andequipment ground is per NEC table 250.122.
Based on NEC:
The master electrician shall be responsible for ensuringthat no feeders or branch circuits are installed in a manneror sized in such a way as to violate the NEC.
Where discrepancies occur between the Feeder scheduleand the grounding charts, the chart shall overrule thefeeder schedule and the NEC shall overrule all schedules.
The service ground chart indicates the minimum serviceground based on #G where # is the ampacity from thechart above, and the equipment ground chart indicates theminimum equipment grounding conductor size #EG where# is the rating/ setting of the overcurrent device protectingthe conductors and equipment.All conductors shall be Copper.
2014
Transformer ScheduleOvercurrentProtection480V, 3Ø
20A50A70A
125A175A225A350A
Notes: Primary shall be 3-wire and secondary shallbe 4-wire unless noted otherwise. All transformers45kVA and below shall be suspended unless notedotherwise. All transformers over 45kVA shall befloor mounted unless noted otherwise. Primaryand secondary feeders shall be sized per the circuitbreaker size and shall be 3-wire on the primary and4-wire on the secondary. For example all 45kVA480/208V transformers with a 480V primary will befed with a 70/3 on the primary and a 150/4 on thesecondary (the bonding and grounding shall beper NEC 250.30A).
kVA - Ground15 - #830 - #645 - #675 - #2
112.5 - #2150 - 1/0225 - 2/0
OvercurrentProtection208V, 3Ø
50A100A150A250A400A500A800A
Based on NEC: 2014
NEMA 3R
EXISTINGGROUND PERNEC 250
BPANEL
150/4
COOKCENTER
200A/3P150A/3P150A/3P
RT-1
RT-2
80A/3P 80A/3P
80/4 80/4
PANEL SCHEDULE: PROJECT:LOCATION:JOB NO.:COMMENTS: BUS RATING:MAIN O.C. DEVICE:MOUNTING: CIR
NO.
1357911131517192123252729313335373941
NOTES:
1.2.
CIRCUIT
AMPS
202020202020202020202020202020202020202020
CONNECTED LOAD:
E.C. to field verify existing conditions prior to any work.Circuits in "BOLD" represent new work.
Cell Service - SuperiorInterior wall16-077Existing Panelboard
BREAKER
POLE
111111111111111111111
PHASE A (VA):PHASE B (VA):PHASE C (VA):
TOTAL LOAD (VA):
225A MLOInterior, Recessed
CONNECTED
LOAD (VA)
1244 933 2000 2000 360 360 1500 2000 900
500 500 500 500 500 500 500 360 360
10,824 9,153 7,620 27,597
A
NEC DEMAND
FACTOR
1.25 1.25 1.00 1.00 1.00 1.00 1.00 1.00 1.00
1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
DESCRIPTION OF
LOAD SERVED
Show Rm & Vesitbule LTGBack of Space LTG
Show WindowShow Window
Restroom ReceptaclesBreak Rm Receptacles
Garbage DisposalTVs, North wall
Show Room Center DropSpareSpareSpare
Sales TVsSales TVsSales TVsSales TVsSales TVsSales TVsSales TVsIT/DATA
TELEPHONE
PHASE
ABCABCABCABCABCABCABC
VOLTAGE L-L:VOLTAGE L-G:SYSTEM: S.C.RMS RATING:
DESCRIPTION OF
LOAD SERVED
Exterior K-4 FixturesBuilding SignSpareExterior K-3 FixutresSpareSpareSpare - Building LTG ContactorSpare - Building LTG ContactorSpareSite LightsSite LightsSite LightsSite LightsSite LightsSite LightsSpareSpareSpareSpareSpare - Building LTG ContactorSpare - Building LTG Contactor
DEMAND LOAD:PHASE A (VA):PHASE B (VA):PHASE C (VA):
TOTAL DEMAND LOAD (VA):
2081203Ø, 4-WIRE
42,000 AIC
NEC DEMAND
FACTOR
1.25 1.25
1.25
1.25 1.25 1.25 1.25 1.25 1.25
12,280 10,511 8,370 31,161
CONNECTED
LOAD (VA)
980 1500
600
1500 1500 1500 1500 1500 1500
86.50
July 7, 2016
CIRCUIT
POLE
111111111222222222211
A
BREAKER
AMPS
202020202020202020303030303030303030302020
CIR
NO.
2468
1012141618202224262830323436384042
PANEL SCHEDULE: PROJECT:LOCATION:JOB NO.:COMMENTS: BUS RATING:MAIN O.C. DEVICE:MOUNTING: CIR
NO.
1357911131517192123252729313335373941
NOTES:
1.2.
CIRCUIT
AMPS
202020202020303030202020202020202020202020
CONNECTED LOAD:
E.C. to field verify existing conditions prior to any work.Circuits in "BOLD" represent new work.
Cell Service - SuperiorInterior wall16-077Existing Panelboard
BREAKER
POLE
111111333111111111111
PHASE A (VA):PHASE B (VA):PHASE C (VA):
TOTAL LOAD (VA):
225A MLOInterior, Recessed
CONNECTED
LOAD (VA)
720 500 900 180 180 180
1080 1080 1080 360 900 720 540 540 360 540 500 500
4,920 5,200 5,240 15,360
B
NEC DEMAND
FACTOR
1.00 1.00 1.00 1.00 1.00 1.00
1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
DESCRIPTION OF
LOAD SERVED
Conference NorthConference TV
Conference SouthCustom SafeCustom Safe
Cash SafeSpareSpareSpare
Sales Desk CenterSales Recept
Sales DeskSales DeskSales DeskSales DeskSales DeskSales DeskSales DeskSales Desk
RACK systemRACK system
PHASE
ABCABCABCABCABCABCABC
VOLTAGE L-L:VOLTAGE L-G:SYSTEM: S.C.RMS RATING:
DESCRIPTION OF
LOAD SERVED
SpareSpareSpareSpareSpareSpareSpareSpareSpareSpareSpareSpareSpareSpareSpareSpareSpareSpareWH-1WH-1WH-1
DEMAND LOAD:PHASE A (VA):PHASE B (VA):PHASE C (VA):
TOTAL DEMAND LOAD (VA):
2081203Ø, 4-WIRE
42,000 AIC
NEC DEMAND
FACTOR
1.00 1.00 1.00
4,920 5,200 5,240 15,360
CONNECTED
LOAD (VA)
1500 1500 1500
42.64
July 7, 2016
CIRCUIT
POLE
333333333333333333333
A
BREAKER
AMPS
303030202020202020505050151515151515505050
CIR
NO.
2468
1012141618202224262830323436384042
PANEL SCHEDULE: PROJECT:LOCATION:JOB NO.:COMMENTS: BUS RATING:MAIN O.C. DEVICE:MOUNTING: CIR
NO.
1357911131517192123252729313335373941
NOTES:
1.2.
CIRCUIT
AMPS
606060505020606060202020202020202020202020
CONNECTED LOAD:
E.C. to field verify existing conditions prior to any work.Circuits in "BOLD" represent new work.
Cell Service - SuperiorInterior wall16-077Existing Panelboard
BREAKER
POLE
333221333111122111111
PHASE A (VA):PHASE B (VA):PHASE C (VA):
TOTAL LOAD (VA):
400A MLOInterior, Recessed
CONNECTED
LOAD (VA)
800
800 0 0 800
C
NEC DEMAND
FACTOR
1.00
DESCRIPTION OF
LOAD SERVED
SpareSpareSpareSpareSpareSpareSpareSpareSpareSpareSpareSpareSpareSpareSpare
Roof Convience OutletSpareSpareSpareSpareSpare
PHASE
ABCABCABCABCABCABCABC
VOLTAGE L-L:VOLTAGE L-G:SYSTEM: S.C.RMS RATING:
DESCRIPTION OF
LOAD SERVED
SpareSpareSpareSpareSpareSpareSpareSpareSpareSpareSpareSpareSpareSpareSpareSpareSpareBussed SpaceBussed SpaceBussed SpaceBussed Space
DEMAND LOAD:PHASE A (VA):PHASE B (VA):PHASE C (VA):
TOTAL DEMAND LOAD (VA):
2081203Ø, 4-WIRE
42,000 AIC
NEC DEMAND
FACTOR
800 0 0 800
CONNECTED
LOAD (VA)
2.22
July 5, 2016
CIRCUIT
POLE
33333333333333322
A
BREAKER
AMPS
5050505050505050505050505050503030
CIR
NO.
2468
1012141618202224262830323436384042
PANEL SCHEDULE: PROJECT:LOCATION:JOB NO.:COMMENTS: BUS RATING:MAIN O.C. DEVICE:MOUNTING: CIR
NO.
1357911131517
NOTES:
1.2.
CIRCUIT
AMPS
150150150150150150200200200
CONNECTED LOAD:
E.C. to field verify existing conditions prior to any work.Circuits in "BOLD" represent new work.
Cell Service - SuperiorInterior wall16-077Existing Panelboard
BREAKER
POLE
333333333
PHASE A (VA):PHASE B (VA):PHASE C (VA):
TOTAL LOAD (VA):
800AMLOInterior, Recessed
CONNECTED
LOAD (VA)
12280 10511 8370 4920 5200 5240
29,400 27,111 25,010 81,521
DP
NEC DEMAND
FACTOR
1.00 1.00 1.00 1.00 1.00 1.00
DESCRIPTION OF
LOAD SERVED
Panel APanel APanel APanel BPanel BPanel BSpareSpareSpare
PHASE
ABCABCABC
VOLTAGE L-L:VOLTAGE L-G:SYSTEM: S.C.RMS RATING:
DESCRIPTION OF
LOAD SERVED
Panel CPanel CPanel CRT-1RT-1RT-1RT-2RT-2RT-2
DEMAND LOAD:PHASE A (VA):PHASE B (VA):PHASE C (VA):
TOTAL DEMAND LOAD (VA):
2081203Ø, 4-WIRE
42,000 AIC
NEC DEMAND
FACTOR
1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
29,400 27,111 25,010 81,521
CONNECTED
LOAD (VA)
800 0 0
5700 5700 5700 5700 5700 5700
226.29
July 7, 2016
CIRCUIT
POLE
333333333
A
BREAKER
AMPS
400400400808080808080
CIR
NO.
2468
1012141618
(DEMO)
FAULT CURRENT CALCULATION TABLE
NOTES:1.2.
3.4.5.
6.
LOCATION (n)300
800A MainDP
Panel APanel BPanel C
RT-1RT-2
All Calculations use Bussman "Point-To-Point" Method.Variables:
The E.C. shall report any discrepancies to the Engineer.Aluminum Conductors, MC Cabling, and Series Rated Panels are not allowed.The E.C. shall verify the Available Fault Current from the Electrical Utility and shall report theactual Fault Current available to the Engineer if different from shown. Fault Currents are basedon Utility information or %Z=1.4 if none are provided.The E.C. shall field verify the Feeder Lengths and report any discrepancy to the engineer.Conductor Lengths listed in this table are engineering estimates and are not intended to representactual lengths for bidding or other calculations. The E.C. shall inform the Engineer immediatelyif the actual lengths are less than that listed.
# of RUNSUtility Transformer
3311211
L=Feeder Length (LF)f(n) = (1.73 x L x F(n-1))/(C x # of runs x Voltage) in Amperes
CONDUCTOR
3503501/01/03/033
VOLTAGE208208208208208208208208
C=Conductor "C" Value
L(ft)
30151515154570
C
22,73719,7048,9258,92512,8444,7744,774
f
0.190.090.560.560.193.144.88
July 5, 2016
M
0.840.920.640.640.840.240.17
M(n) =1 ÷ (1+f(n))F(n)=F(n-1) x M(n)
F 52,00043,68940,00125,65525,65533,4949,6716,805
E0.0ELECTRICAL ONE-LINE,NOTES & SCHEDULES
Sheet:
Project Number:
4303 Brighton Blvd., Building #3Denver, Colorado 80216720-891-8703
General Contractor:
Owner:Cellular Sales9040 Executive Park DriveKnoxville, TN 37923Contact: Colby Smith
Structural Engineer:
MEP Engineer:
Number:
7/4/
2016
12:
56:4
2 P
M
kVA 16-077
Cel
lula
r Sal
es -
Sup
erio
r30
4 M
arsh
all R
d.S
uper
ior,
CO
Issued For: DatePERMIT 07.08.16
E1.01 POWER PLAN
1/4" = 1'-0"SCALE:
Conference Room106
Toilet108
Toilet107
Service105
Inventory102
Break104
Show Room101
Vestibule100
Corridor103
ProjectNorth
RT
1
XXEQUIPMENT SCHEDULE
KEY
RT-1
RT-2
EF-1,2, 3
WH-1
NOTES:1.2.3.
EQUIPMENT
ROOFTOP UNIT7.5-TONROOFTOP UNIT7.5-TONEXHAUST FAN
WATER HEATER
Field verify final location and electrical requirements of all equipment with provider prior to rough-in.Provide line voltage controls and wiring as required. Field verify control requirements with provider.Provide HACR breakers for all circuits serving equipment.
LOADHP,KW,FLA44.9A MCA50A MOCP44.9A MCA50A MOCP
49W
4500W
VOLTS
208
208
120
208
Ø
3
3
1
3
BRANCH CKT.CONDUCTORS
4#6,#10G
4#6,#10G
2#12,#12G
4#10,#10G
CONDUIT
1-1/4"
1-1/4"
3/4"
3/4"
DISCONNECTSWITCH50A/3P
WP50A/3P
WPSto
Sto
FUSE50A/3P
50A/3P
NA
NA
July 5, 2016CIRCUIT
DP-8,10,12
DP-14,16,18
SEE PANELSCHEDULESB-38,40,42
NOTES
1
1
1,2
1
EF
2
EF
1
M
WH
1
TTB
2A-41
IT
A-393
PANEL"C"
PANEL"B"
PANEL"DP"
PANEL"A"
61
CEILING
A-5
1CEILING
A-5
1
CEILING
A-5
1
CEILING
A-71
CEILING
A-7
AG
AG
AG
GFIC
GDA-13
EF
3
RT
2
A-9
A-9
A-11
A-11
A-15
A-15
A-15
5
A-15
5B-31
5
A-27
A-29
B-27
A-3160"AFF
60"AFF
FLOOR
B-23
B-1
B-5
B-1
B-1
B-5B-5
B-19B-19
B-7
80"AFFB-25FLOOR
B-35FLOOR
60"AFF
B-2360"AFF
5
48"AFF
5
A-2580"AFF
5
A-3580"AFF
FLOOR FLOOR
5
B-380"AFF
B-2360"AFF
B-2960"AFF 48"AFF
FLOOR
FLOOR
FLOOR
CEILING
FLOOR
FLOOR
80"AFF5
A-1580"AFF
5
A-1580"AFF
5
A-1580"AFF
B-3160"AFF
48"AFF
5B-33
A-3360"AFF B-33
60"AFF
48"AFF
5B-37
A-3760"AFF
48"AFF
A-17A-17
B-19
B-9 B-11 B-41
B-2148"AFF
B-2148"AFF
B-2148"AFF
B-29
B-27
B-39
7
7
7
7
7
Sheet:
Project Number:
4303 Brighton Blvd., Building #3Denver, Colorado 80216720-891-8703
General Contractor:
Owner:Cellular Sales9040 Executive Park DriveKnoxville, TN 37923Contact: Colby Smith
Structural Engineer:
MEP Engineer:
Number:
7/4/
2016
12:
56:4
2 P
M
kVA 16-077
Cel
lula
r Sal
es -
Sup
erio
r30
4 M
arsh
all R
d.S
uper
ior,
CO
Issued For: DatePERMIT 07.08.16
E1.0POWER PLAN
E1.1DATA/POWER LAYOUT BY
OTHERS
Sheet:
Project Number:
4303 Brighton Blvd., Building #3Denver, Colorado 80216720-891-8703
General Contractor:
Owner:Cellular Sales9040 Executive Park DriveKnoxville, TN 37923Contact: Colby Smith
Structural Engineer:
MEP Engineer:
Number:
7/4/
2016
12:
56:4
2 P
M
kVA 16-077
Cel
lula
r Sal
es -
Sup
erio
r30
4 M
arsh
all R
d.S
uper
ior,
CO
Issued For: DatePERMIT 07.08.16
ProjectNorth
E2.01 LIGHTING PLAN
1/4" = 1'-0"SCALE:
Show Room101
Conference Room106
Corridor103
Break104
Inventory102
B BBB
B BBB
B BBB
B BBB B BBB
B BBB
B BBB
BBB
B
B
B
B
A A A AA
A
AA
AAA
A A A
S1 S1 S1
A
XR
XR
XEM
XEM
XX
LUMINAIRE SCHEDULEKEY
INTERIOR FIXTURES
A
B
S1
EM
X
XEM
XR
NOTES: (Notes apply to all fixtures where applicable)
1.
2.
3.
4.
5.
6.
DESCRIPTION
2'x4' LED TROFFER
EDGE LIT TECHNOLOGY 0-10V DIM
2'x2' LED TROFFER
EDGE LIT TECHNOLOGY 0-10V DIM
LED LENSED STRIP LIGHT
4100LM
EMERGENCY PACK
FROG-EYE W/ 90 MINUTE BATTERY PACK
EXIT SIGN - POLYCARBONATE
W/ 90 MINUTE BATTERY PACK
FROG-EYE/EXIT COMBINITAION
W/ 90 MINUTE BATTERY PACK
ARCHITECTURAL WP EMERGENCY LIGHT
W/ 90 MINUTE BATTERY PACK, SILVER FINISH
EMERGENCY FIXTURES - All Fixtures Indicated as Emergency shall be provided with a 90-Minute Battery Pack and all Fluorescent Fixtures
indicated as Emergency shall be provided with a 1300 Lumen, 90-Minute Battery Pack.
VERIFY VOLTAGES - The E.C. shall verify voltages on drawings prior to ordering or any work, the engineer shall be notified of any descrepancies
in the voltage of the circuiting on the drawings and the luminiare schedule prior to any purchase or work.
VERIFY LAMPING - The E.C. shall verify lamping with the manufacturer prior to ordering and notify the engineer of any lamping descrepancies.
PROVIDE A COMPLETE INSTALLATION - The E.C. shall provide all labor and material to provide a complete and functional system per the design intent as dictated by the
switching type and location (including dimmer switches and compatible ballasts or transformers), ceiling type and location, circuiting, voltages, and lamping types.
BALLAST DISCONNECT - All electric discharge luminaires shall comply with NEC 410.130 and shall have a means of disconnect for the ballast.
DUAL LEVEL SWITCHING - For fixtures with more than one switch designation shown on plans provide fixtures with additional ballasts for dual level light
control by separate switching of inboard and outboard lamps as required to conform to IECC Requirements.
MFR. & CAT.NO.
COOPER - METALUX
24EN-LD1-54-UNV-L8XX-CD1-U
COOPER - METALUX
22EN-LD1-34-UNV-L8XX-CD1-U
COOPER - METALUX
4SNLED-LD4-41SL-LN-UNV-L8XX-CD1-U
COOPER - SURE-LITES
APEL
COOPER - SURE-LITES
AP70 G UNV
COOPER - SURE-LITES
AP70 G DH UNV
COOPER - SURE-LITES
AEL1SD
LAMP
54W LED
INTEGRAL
34W LED
INTEGRAL
41WLED
INTEGRAL
.78 W LED
INTEGRAL
LED
LED/ 5.4W INC
3-6V,6W, XENON
VOLTS
120/277
120/277
120/277
120/277
120/277
120/277
120/277
July 5, 2016
MOUNTING
INFORMATION
RECESSED
RECESSED
SURFACE
SURFACE
SURFACE
SURFACE
SURFACE
NOTE
EM
EM
EM
XEMJ
J 3
3
a a a
aaa
a
a
a a a a
a b
b
b b b
b b
b
bbbbbb
b
b
b
b
b bbb
c N.L.
N.L.
N.L.N.L.
N.L. N.L.
abc
A-1
2
2(TYP., 4)
2
(TYP., 2)1
1
1
A-1A-1
A-2
A-2
A-2
A-2
A-2
A-2
A-2 A-2
E2.0LIGHTING PLAN
Sheet:
Project Number:
4303 Brighton Blvd., Building #3Denver, Colorado 80216720-891-8703
General Contractor:
Owner:Cellular Sales9040 Executive Park DriveKnoxville, TN 37923Contact: Colby Smith
Structural Engineer:
MEP Engineer:
Number:
7/4/
2016
12:
56:4
2 P
M
kVA 16-077
Cel
lula
r Sal
es -
Sup
erio
r30
4 M
arsh
all R
d.S
uper
ior,
CO
Issued For: DatePERMIT 07.08.16