Certificate No.: FRPP17511

Franklin Offshore Australia Pty Ltd

ABN 64 082 781 691Certificate No.:

CERTIFICATE OF LOAD TEST AND EXAMINATION

Address:Order No: Test Date:ORONTIDE MADCO

LOT 560 SPARKS ROAD HENDERSONP000112356 14/12/2018Client:

ClientID: SG-D252962/ FHH6040

7 Possner WayHENDERSON WA 6166Tel: 61-8-9410-6000 Fax: 61-8-9410-6001

Job Sheet No: 12405

6m half height container

Length: 6058mmWidth: 2438mmHeight: 1436mm

Tare: 3550kgNett: 9750kgMGM: 13300kg

13300kg33.25 tonnes on4 points

DNVGL-ST-E271:20171

Remarks

The items were found to comply to test specifications as detailed above.

The above test was performed by a competent person in accordance with the information provided.

Accredited Number: 3073Date of Issue:

Printed Name:

Signatory:

TestType

ANDREW BRIGGS

09/01/2019

PROOFLOAD

Form WIADM-007 Rev. 3

Accredited for compliance with ISO/IEC 17025

Manufacturer:

Surface Finish: PAINT

FERGUSON SEACABSLoad cell used: 55T tension Serial number: 7795

Page of1 1

Location of Test: Franklin Offshore Australia, 7Possner Way, Henderson

Page 4: Certificate No.: FRPP17511 CERTIFICATE OF LOAD TEST AND

Franklin Offshore Australia Pty Ltd

ABN 64 082 781 691

CERTIFICATE OF MAGNETIC PARTICLE INSPECTION

Certificate No.: FRNP4624

Test Date: 27/11/2018

Test Date: 27/11/2018

7 Possner WayHENDERSON WA 6166Tel: 61-8-9410-6000 Fax: 61-8-9410-6001

Order No: P00109116Client:

Address:

ORONTIDE MADCO PTY LTD

46 SPARKS ROAD HENDERSON PERTH W.A 6166 Job Sheet: 12405

WCP: 26917BMI: 0917137

THIS TEST REVEALED NIL SURFACE DISCONTINUITIES OUTOF SPECIFICATION TO THE ABOVE ACCEPTANCECRITERIA AT THE TIME OF INSPECTION.

WELDS TESTED COMPLY.

TEST RESTRICTIONS: NIL

LOAD TEST NO.: FRPP16522 11/18

Material Spec:

Product Spec: Procedure No:

Test Sheet No:

Technique:

Penetrant Contact Time:

Developer Time:

Job Description:

Test Specification:

Acceptance Criteria:

Surface Condition:

Method of Surface Preperation:

Client ID:

TestID:

LOCATION AND ADDRESS OF TEST CONDUCTED:

TECHNICIAN:

CARBON STEEL

EDGARDO GARCIA

FRNP4624

MAGNETIC FLOW

WIWS 037 REV8

4624

FERRO-MAGNETIC

N/A

POWER WIRE BRUSHED

Magnaflux Y6: #7

AS WELDED

Franklin Offshore Australia, 7 Possner Way, Henderson

FHH6040

Approved Signatory:

DEAN OSBOINEPrinted Name:

Date of Issue: 22/01/2019

N/A

AWS D1.1: 2015-T 6.1

AS 1171-1998

Accredited for Compliance with ISO/IEC 17025

Accredited Number: 3073

Test Results / Indications :

NON COMPLIANTCOMPLIANT /

Batch Number:Equipment/Test Medium:

Pre and Post magnetic particle on 6m Half height container's four lifting lug weld attachments and Post-MPI on welds ofrepaired portions.

Form WIADM-007 Rev. 3

Page 5: Certificate No.: FRPP17511 CERTIFICATE OF LOAD TEST AND

E:[email protected]

www.proofload.com.au 1 of 1

Certificate No. Job No.

CERTIFICATE FOR OFFSHORE CONTAINER LIFTING SLINGS Customer:

Customer Order No.

Customer Address:

Manufacturer: Address:

DNV Type Approval No. Type Designation:

Working Load Limit: Angle of Legs (To Vertical): No. / Dia. of sling legs: Length of legs:

Description of sling: ID No/Markings:

Wire Rope Slings Reference Standard: Grade of Wire Rope: Grade of terminal fittings:

QUAD: SHACKLES:

Chain Slings

Reference Standard: Material Grade: Reference to testing of mechanical properties after heat treatment:

Tests carried out on sling:

Lifting Set Components

Description Supplier/Manufacturer Identification Mark DNV Type Approval No.

The lifting set has been designed, approved and tested in accordance with DNVGL-ST-E271 “2.7-1 Offshore Containers"

The sling also conforms to the following standard(s):

Remarks:

DATE OF TEST:

APPROVED SIGNATORY

Head Office: 35 Resource Way, Malaga, WA 6090 P +61 8 92481288

Doc N.O. T-FR-0041 Rev. 0004

Hoover Ferguson Pty Ltd

FGA-PO007948

16 Alacrity Place, Henderson, WA 6166

Proofload Pty Ltd (Certificate Issuer) 35 Resource Way, Malaga, WA 6090

S-8398 N/A

13.3 Tonne 45° 4/26mm 4.57 Metres

26mm Grade 1960 4 Leg Wire Rope Assembly with Fram Q38B Masterlink Assembly and 9.5t Safety Bow Shackles

FSA260

AS3569 1960

N/A N/AN/A

133kN Each Leg, 264.9kN Masterlink, 186.4kN Shackles

Wire RopeMasterlinkShackles

Usha MartinFramVan Beest

D011/1920/43SABS6/BS6

N/ATAS0000048TAS00001D0

EN13414-1 & AS1666.1-2009

Shackles Stamped "260 A-D"4 Legs Replaced

17/07/2020

PDV2006 7205

80 60

Devon Haskins

Page 6: Certificate No.: FRPP17511 CERTIFICATE OF LOAD TEST AND
bw01
Line
bw01
Line
bw01
Line
Page 7: Certificate No.: FRPP17511 CERTIFICATE OF LOAD TEST AND

Certificate of Visual Inspection

Certificate Number 166110

Ferguson Group Australia Pty Ltd trading as Hoover Ferguson

16 Alacrity Place

Henderson

WA 6166

14-Jan-2021 6M/20ft Half Height (Removable Sides)

6.058

2.438

1.436

3,550

9,750

13,300

14-Dec-2018

Date of Current Examination

Dimensions Equipment OwnerWeights Date of Previous

Examination

Date of Next

Examination/Test

Date of Current Proof

Load & Certificate Number

Length

Width

Height

Tare

Payload

Gross

Number & Position of Pad Eyes:

Lifting Set Description & ID Numbers Safe Working Load

Address of the premises at which the

examination was made

Cert Additional NotesInspector Name

FSA260

260A-D

Working Load Limit / Angle of Lift

13.3

9.5

FHH6040

Date Of Next

Examination/Test

13-Jan-2022

13-Jan-2022

27-Jul-2020

4 leg wire rope sling

4 Safety Pin Bow Shackles

Ferguson Group Australia Pty Ltd

16 Alacrity Place Henderson

Australia WA 6166

Kgs

Kgs

Kgs

Mtrs

Mtrs

Mtrs

t @ 0-45 deg

Joel Agnete

t

4 Top Mounted

FRPP17511

NO DEFECTS EVIDENT, INSPECTION PLATE

AND SLING TAG MARKED AS REQUIRED

Ferguson Group Pty Ltd,

16 Alacrity Place, Henderson

Australia WA 6166

Equipment ID No Unit Description

Inspection

Procedure

Inspection

Result

PASS

Sling Desc

Sling ID No.

Shackle Desc

Shackle ID No.

Last Date of Non-Destructive Testing: 24-Jan-2019 No Surface Defects were found at time of Inspection

13-Jan-2022

Pressure Test Run Out Hydrostatic Run Out

N/A N/A

In accordance with

DNV 2.7-1. Section

9.2 and Section 9.3

Accredited for compliance with ISO/IEC 17020.

NATA Accredited Inspection Number 16907.

This document must only be reproduced in full.

Page 1 of 1

Date of Issue 14-Jan-2021

Signed

Delegated Signatory Brenda Wych