Coast Spa Manufacturing Inc.6315-202 Street
Langley, British ColumbiaV2Y1N1, Canada
Date: March 26, 2017Report No.: 9586-2SRevision No.: 5Project No.: 16178Equipment: Whirlpool SpaSeries.: Acapulco 2000 (International Model Series)
ONE STOP GLOBAL CERTIFICATION SOLUTIONS
C€ c\A-iv-yus
\^
^www.ltac.oTgi
v'>';;:l^s'~^
'"•.Lii"1'
[LC) (iC]>1'1.;>^~
3133-20800 Westminster Hwy, Richmond, BCV6V 2W3, Canada
Phone: 604-247-0444Fax: 604-247-0442
www.labtestcert.com
^-Prepared by: LabTest Certification Inc.Date Issued: March 26, 2017Project No.: 16178
Client:Coast Spa Manufacturing Inc.Report No.:9586-2S
Revision No.: 5
TABLE OF CONTENTS
TEST REPORT..................................................................................................................................3
Model Description...............................................................................................................................9
Summary of Testing ........................................................................................................................ 18
Construction Evaluation: ................................................................................................................. 19
List of Critical Components ............................................................................................................. 91
Test Equipment Used...................................................................................................................... 93
FIGURES AND SCHEMATICS ....................................................................................................... 94
Photographs.................................................................................................................................. 102
Appendix A-Test Data ................................................................................................................ 131
Appendix B - Component Certificates .......................................................................................... 189
Appendix C - ISO 17025:2005 Accreditation Certificate.............................................................. 201
2 of 204
CONFUTIAt,
Prepared by: LabTest Certification Inc.Date Issued: March 26, 2017Project No.: 16178
Client:Coast Spa Manufacturing Inc.Report No.:9586-2S
Revision No.: 5
TEST REPORT
IEC 60335-2-60:2002 (Third edition) + A1:2004 + A2:2008 in conjunction with IEC60335-1:2010 (Fifth Edition) + A1:2013
9586-2SReport reference No.
Report Revision History: |RevO-March3,2010
I Rev 1: Add clarification for model designations-July 28, 2010
Rev 2: Revised rating labels - September 2, 2010
I Rev 3: Update comments for Clause 14, 19.11.4, 30.2.3-Sept. 10,2010
j Rev 4: Removed Gecko Spa Pack controller
Rev5: Report update with the latest standard EN 60335-2-60:2002 (Third1 edition) + A1:2004 + A2:2008 with EN 60335-1:2010 (Fifth Edition) +A1:2013.
Reviewed and complied by(printed name and signature)
.i Sandeep Bhayana
I Kavinder Dhillon, Eng.L.]iApproved by|| (printed name and signature)
I Date of issue ....................................:! March 26, 2017
Note: By signing this report, both the Testing Technician and the Reviewer hereby declare to abide by the applicable LabTest policies:1.) Statement of Independence # 3014 (LabTest Employees),
s 2.) Independence, Impartiality, and Integrity #1039, clause 11 (Engineering Service Subcontractors), or
|s 3.) Independence, Impartiality, and Integrity #1019, clause 3.5 (Testing Subcontractors).
||Testing Laboratory Name .............: | LabTest Certification Inc.
11 Address 3133 - 20800 Westminster Hwy, Richmond, B.C. V6V-2W3
ITest Location Name .....................: I LabTest Certification Inc.
Address ............................................: 13133 - 20800 Westminster Hwy, Richmond, B.C. V6V-2W3
'{~~~~~~~~~
Applicant's Name ..........................: [Coast Spa Manufacturing Inc.
[Address
Test specification
6315 - 202 Street, Langley, British Columbia, V2Y 1N1, Canada
Standards
Test procedure
EN 60335-2-60:2002 (Third edition) +A1:2004 +A2:2008 withEN 60335-1:2010 (Fifth Edition) +A1:2013
CB -scheme
Non-standard test method NA
Test item description
Manufacturer Coast Spa Manufacturing Inc.
Series
Model tested
Acapulco 2000 (International Model Series)
> Configuration Model # EEF-45 (Freedom)
> Configuration Model # EHMI-82 (Mirage)
> Configuration Model # EEV-55 (Vantage)
Serial numbers 9100410,7080278,10010092
Rating(s) > 230-240Vac, 50Hz, 16A, 3 Phase
> 230-240Vac, 50Hz, 32A, 1 Phase
3 of 204
CONFIDENTIAL
Prepared by: LabTest Certification Inc.Date Issued: March 26, 2017Project No.: 16178
ClientCoast Spa Manufacturing Inc.Report No.:9586-2S
Revision No.: 5
li Particulars: test item vs. test requirements
1 Mass of tested equipments, dry weight (kg): Configuration Model # EHMI-82-748.3Kg, ConfigurationModel # EEF-45-585Kg, Configuration Model # EEV-55(Vantage)-415.9Kg.
Protection against ingress of water ............ : IPX5
Classification of installation and use.................. Class I, indoor and outdoor use, Permanent installation
Supply Connection............................................. AC
Degree of protection........................................... IPX5
llwhirlpool bath .................................................... No
1 Whirlpool spa...................................................... ^es
||Whirlpool spa located outdoor........................... Yes
Provided with blower.......................................... Yes
Provided with pump............................................ Yes
Provided with chlorinator.................................... No
Thermal cut-out Yes
Heating element................................................. Yes
External supplied hot water............................... No
Automatically drained after each use ............... No
Appliance with luminaries/LED
Replaceable lamp/LED.
Test case verdicts
Test case does not apply to the test object :
Test item does meet the requirement ........:
Test item does not meet the requirement ..:
Testing
Date of receipt of test item .........................:
Date(s) of performance of test ...................:
Yes, provided with LED
.Yes
N/A
p
F
December 30, 2009
December 30, 2009 thru January 29,2010
4 of 204