cgpm 2003 ccauv report president: dr. joaquín valdés (cipm)

20
1 CGPM 2003 CCAUV report President: Dr. Joaquín Valdés (CIPM) Executive Secretary: Dr. P. Allisy-Roberts (BIPM)

Upload: ashley

Post on 08-Feb-2016

27 views

Category:

Documents


1 download

DESCRIPTION

CGPM 2003 CCAUV report President: Dr. Joaquín Valdés (CIPM) Executive Secretary: Dr. P. Allisy-Roberts (BIPM). CCAUV first meeting July 1999 CCAUV second meeting October 2001 CCAUV third meeting October 2002 28 delegates, 5 observers and 1 guest. CCAUV Summary of Comparison Status. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: CGPM 2003 CCAUV  report President: Dr. Joaquín Valdés (CIPM)

1

CGPM 2003

CCAUV report

President: Dr. Joaquín Valdés (CIPM)

Executive Secretary: Dr. P. Allisy-Roberts (BIPM)

Page 2: CGPM 2003 CCAUV  report President: Dr. Joaquín Valdés (CIPM)

2

CCAUV first meeting July 1999

CCAUV second meeting October 2001

CCAUV third meeting October 200228 delegates, 5 observers and 1 guest

Page 3: CGPM 2003 CCAUV  report President: Dr. Joaquín Valdés (CIPM)

3

CCAUV

Summary of Comparison Status

Page 4: CGPM 2003 CCAUV  report President: Dr. Joaquín Valdés (CIPM)

4

AcousticsCCAUV Key RMO Key RMO Suplement

A-K1 Published APMP K1 Planned SIM Measurements complete

A-K2 Planned COOMET K1 In progress

A-K3 In Progress EUROMET K1 Draft B

A-K4 Planned EUROMET K2, K3 Planned

W-K1 Draft A SIM K1 Draft B

SIM K1 (old) approved

Page 5: CGPM 2003 CCAUV  report President: Dr. Joaquín Valdés (CIPM)

5

Ultrasound

CCAUV Key RMO KeyU-K1 Published EUROMET K1 Planned

U-K2 In progress EUROMET K2 Planned

Page 6: CGPM 2003 CCAUV  report President: Dr. Joaquín Valdés (CIPM)

6

Vibration

CCAUV Key RMO Key

V-K1 Published APMP K1 Approved (linked results to be published)EUROMET K1 (old) approved

EUROMET K1 In progress

SIM K1 Draft A

Page 7: CGPM 2003 CCAUV  report President: Dr. Joaquín Valdés (CIPM)

7

Estimation of the uncertainties.

Stability of the objects circulated.

Reference standard microphonesinvolved.

Page 8: CGPM 2003 CCAUV  report President: Dr. Joaquín Valdés (CIPM)

8

Classification of Services in AUV

Document CCAUV 02 - 05

Page 9: CGPM 2003 CCAUV  report President: Dr. Joaquín Valdés (CIPM)

9

Future Needs for Metrology in AUV

Report prepared by NPL (UK), PTB (Germany), IEN (Italy)

and the President of CCAUV

Document CCAUV 02 - 33

Page 10: CGPM 2003 CCAUV  report President: Dr. Joaquín Valdés (CIPM)

10

AUV and Nanotechnology

Need to develop ever smaller transducers

Page 11: CGPM 2003 CCAUV  report President: Dr. Joaquín Valdés (CIPM)

11

Page 12: CGPM 2003 CCAUV  report President: Dr. Joaquín Valdés (CIPM)

12

Achieving vibrational quantum limits with nanomembranes

New standards with acoustical or thermal phonons?

PHONON EMISSION ONE BY ONEPHONON EMISSION ONE BY ONE

Page 13: CGPM 2003 CCAUV  report President: Dr. Joaquín Valdés (CIPM)

13

Schematic diagram of micromachined stereocilia mounted on a membrane, with piezoresistive strain sensors to measure deflection due to microflows (W. Tang).

Array of micromachined stereocilia.

Page 14: CGPM 2003 CCAUV  report President: Dr. Joaquín Valdés (CIPM)

14

In the CCAUV section of the BIPM websitethere are documents of restricted access.

Most of them will be now be open for free access.

There is also an extense list of publications related to AUV.

Page 15: CGPM 2003 CCAUV  report President: Dr. Joaquín Valdés (CIPM)

15

The unit one,

the neper and the bel

Page 16: CGPM 2003 CCAUV  report President: Dr. Joaquín Valdés (CIPM)

16

Logic A (current logic)

– The ratio of two quantities of the same kind is a new quantity.

Page 17: CGPM 2003 CCAUV  report President: Dr. Joaquín Valdés (CIPM)

17

Logic B• Division of one quantity by other of the same

kind merely express the number of times one quantity fits into the other.

• This number may be just called a coefficient, a factor or a ratio, but not a new quantity.

• No need to assign SI units to numbers!

Page 18: CGPM 2003 CCAUV  report President: Dr. Joaquín Valdés (CIPM)

18

Logic A or Logic B?

It is a matter of choice

Page 19: CGPM 2003 CCAUV  report President: Dr. Joaquín Valdés (CIPM)

19

PROBLEMS associated with Logic A

• CONFUSIONbetween levels, reference levels and the underlying quantities and SI units

• CONFUSION through special names

• CONFUSION through the use of the special name decibel with different power and field quantities such as dB(mW), dB(W), dB(0.775V), dB(V), dB(mA), dB(V/m), dB(W/m2), dB(W/4kHz), dB(W/K), dB(W/m2kHz), dB(kHz), dB(Pa), dB(Pa/V), dB(mV/Pa) and dB(K-1)

Page 20: CGPM 2003 CCAUV  report President: Dr. Joaquín Valdés (CIPM)

20

The best recommendation should be to use more the accepted SI units underlying such ratios or levels as bel or neper