chandra calibration status

28
Chandra Calibration Status Chandra Calibration Status CUC Meeting Oct. 10, 2012 CUC Meeting Oct. 10, 2012

Upload: berg

Post on 12-Jan-2016

57 views

Category:

Documents


0 download

DESCRIPTION

Chandra Calibration Status. CUC Meeting Oct. 10, 2012. Timetable for detector QE and gain updates Calibration updates since the 2011 CUC meeting Cross-calibration results On-going calibration activities Calibration plans for the upcoming year. Chandra Calibration Status. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Chandra Calibration Status

Chandra Calibration StatusChandra Calibration Status

CUC Meeting Oct. 10, 2012CUC Meeting Oct. 10, 2012

Page 2: Chandra Calibration Status

Chandra Calibration StatusChandra Calibration Status

Timetable for detector QE and gain updates

Calibration updates since the 2011 CUC meeting

Cross-calibration results

On-going calibration activities

Calibration plans for the upcoming year

Page 3: Chandra Calibration Status

Timetable for Detector Gain and QE Updates

Detector Gain Updates QEU updates at present

QEU updates by Dec. 2012

ACIS-S Quarterly None Yearly

ACIS-I Quarterly None Yearly

HRC-I Yearly None None

HRC-S Yearly Yearly Yearly

Page 4: Chandra Calibration Status

An updated ACIS contamination model (CALDB 4.4.1 - May 30, 2012)

Time-dependent gain corrections for epochs 47-50 ( Aug 2011 – July 2012)

Calibration products released over the past year

ACIS

HRC

HRC-I gain map for 2011 (CALDB 4.4.7 - Dec. 15, 2011) HRC background spectra for 2011 (CALDB 4.4.7 – Dec. 15, 2011) Updated low energy HRC-S QE (CALDB 4.4.7 – Dec. 15, 2011) Updated HRC-I and HRC-S de-gap maps (CALDB 4.5.0 – Jun. 6,

2012) HRC-S gain map for new HV setting (CALDB 4.5.1 – Jul. 24, 2012)

HETG

Updated HEG and MEG first order transmission efficiencies (CALDB 4.4.6.1 – Dec. 1, 2012)

Page 5: Chandra Calibration Status

ACIS Contamination Model N007ACIS Contamination Model N007

Updated time-dependence

(700 eV)

Black data points are ECS measurements and red and blue data points are ACIS-I and ACIS-S observations of A1795

Page 6: Chandra Calibration Status

ACIS Contamination Model N007ACIS Contamination Model N007

Updated spatial distribution model

(center to edge)

Page 7: Chandra Calibration Status

Cross-calibration with E0102Cross-calibration with E0102

O VIIO VIIINe IXNe X

Page 8: Chandra Calibration Status

MEG and HEG first order transmission efficiencyMEG and HEG first order transmission efficiency

Simultaneous fit to 30 blazars

Page 9: Chandra Calibration Status

HEG/MEG first order transmission efficiency (Capella)

Old CALDB

Old CALDB

Current CALDB

Current CALDB

Page 10: Chandra Calibration Status

July 2012 observations of Mkn 421July 2012 observations of Mkn 421

HETG/ACIS-S LETG/ACIS-S

Page 11: Chandra Calibration Status

Planned AO-14 Calibration ObservationsPlanned AO-14 Calibration Observations

Page 12: Chandra Calibration Status

Adjustment to low energy

HRC-S QE

QE adjustment was based on the latest non-LTE pure H model atmospheres for HZ43 and Sirius B from the Tubingen group

Fits to co-added HZ spectra

Page 13: Chandra Calibration Status

LETG/HRC-S Zeroth Order Image Distortion

0.625” radius circle

CRSV98+99 CRSV100

Page 14: Chandra Calibration Status

Updated HRC-S De-Gap Map

Page 15: Chandra Calibration Status

LETG/HRC-S observations of HZ43 over the course of the mission

New HV

New HV

Current Calibration Projects

Page 16: Chandra Calibration Status

HRC-S High Voltage Test - Jan. 2012

LETG/HRC-S observations of HZ43

Page 17: Chandra Calibration Status

LETG/HRC-S observations of HZ43 over the course of the mission

New HV

New HV

Current Calibration Projects

Page 18: Chandra Calibration Status

LETG/HRC-S observations of Mkn 421 with old and new HV settings

Page 19: Chandra Calibration Status

LETG/HRC-S observations of Mkn 421 with old and new HV settings

Page 20: Chandra Calibration Status

New Time-Dependent ACIS QE Maps

ACIS-S3ACIS-I3

Page 21: Chandra Calibration Status

Stability of HRC-I QE

G21.5-09HZ43

2.6 ± 0.8 % yr-1

Page 22: Chandra Calibration Status

Gain Calibration – ACIS-S1

Page 23: Chandra Calibration Status

ACIS Background

Page 24: Chandra Calibration Status

SAOTrace New Features – New Scattering Model

10’

Page 25: Chandra Calibration Status

Summary of Present Calibration ActivitiesSummary of Present Calibration Activities

Release HRC-S QE for new HV setting

Release updated gain tables and OSIP files for ACIS BI chips

Release a set of time-dependent ACIS QE maps

Release Epoch F ACIS blank sky background images

Short term:

Longer term:

ACIS

Continue to improve the contamination model

How variable is the charged particle background spectrum

Further cross-calibration studies

Page 26: Chandra Calibration Status

Improve the calibration of the intrinsic spatial response of the HRC (e.g., (two gaussians plus a Lorentzian)

Monitor the decline in the gain and QE of the HRC-I and determine if a time-dependent QE is required

Further cross-calibration studies

Update HRC-I QE map

HRC

HETG

Develop a science thread for the analysis of HETG/ACIS-S CC-mode data

Page 27: Chandra Calibration Status

Revisit cross-calibration between LETG and HETG at short wavelengths with the new HEG and MEG first order efficiencies.

Revisit C-K fine edge structure using new absorption coefficients for ISM C-K edges

Improve LETG/HRC-S EE fractions (i.e., the fraction of all events extracted in the cross-dispersion direction)

Improve the calibration of the LETGS resolving power

LETG

Page 28: Chandra Calibration Status

Comparision of optial depth at 700 eV derived from Comparision of optial depth at 700 eV derived from imaging and gratings dataimaging and gratings data

ECS and A1795

LETG/ACIS-S