CHAPTER 3 Heat Transfer Enhancement of a Gas Turbine Blade-Tip Wall G. Xie 1 & B. Sunden 2 1 School of Mechatronics, Northwestern Polytechnical University, Shaanxi, China. 2 Department of Energy Sciences, Lund University, Lund, Sweden. Abstract The blade-tip region encounters high thermal loads because of the hot gas leak- age flows. A common way to cool blade tips is to design serpentine passages with 180° turn with the blade-tip walls inside the turbine blades. Improved internal convective cooling is therefore required to increase blade-tip lifetime. This chap- ter summarizes the heat transfer enhancement of an internal blade-tip wall having pins, dimples and protrusions, and the influence of guide ribs and pins material. It is found that the pinned tip exhibits best performance to improve the blade-tip cooling. However, when considering the added mechanical stress, making dimples is a more suitable way especially at low Reynolds numbers. Properly designed guide ribs might reduce the pressure loss. Keywords: Blade-tip wall; heat transfer enhancement; numerical simulation 1 Introduction The heat load transferred to a gas turbine blade is continuously increased with the increase of the turbine inlet temperature. The blades can only survive if effec- tive cooling methods are used to remove the heat load from the turbine blades. Cooling of the blade should include the cooling of all regions exposed to high temperature gas and thermal load. The blade-tip area is such a region particularly for high-pressure turbines. The hot leakage flow increases the thermal loads on the blade tip, leading to high local temperature. It is therefore very essential to cool doi:10.2495/978-1-84564-818-3/003 www.witpress.com, ISSN 1755-8336 (on-line) WIT Transactions on State of the Art in Science and Engineering, Vol 63, © 2013 WIT Press

Upload: others

Post on 20-Oct-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

  • CHAPTER 3

    Heat Transfer Enhancement of a Gas Turbine Blade-Tip Wall

    G. Xie1 & B. Sunden21School of Mechatronics, Northwestern Polytechnical University, Shaanxi, China.2Department of Energy Sciences, Lund University, Lund, Sweden.

    Abstract

    The blade-tip region encounters high thermal loads because of the hot gas leak-age fl ows. A common way to cool blade tips is to design serpentine passages with 180° turn with the blade-tip walls inside the turbine blades. Improved internal convective cooling is therefore required to increase blade-tip lifetime. This chap-ter summarizes the heat transfer enhancement of an internal blade-tip wall having pins, dimples and protrusions, and the infl uence of guide ribs and pins material. It is found that the pinned tip exhibits best performance to improve the blade-tip cooling. However, when considering the added mechanical stress, making dimples is a more suitable way especially at low Reynolds numbers. Properly designed guide ribs might reduce the pressure loss.

    Keywords: Blade-tip wall; heat transfer enhancement; numerical simulation

    1 Introduction

    The heat load transferred to a gas turbine blade is continuously increased with the increase of the turbine inlet temperature. The blades can only survive if effec-tive cooling methods are used to remove the heat load from the turbine blades. Cooling of the blade should include the cooling of all regions exposed to high temperature gas and thermal load. The blade-tip area is such a region particularly for high-pressure turbines. The hot leakage fl ow increases the thermal loads on the blade tip, leading to high local temperature. It is therefore very essential to cool

    doi:10.2495/978-1-84564-818-3/003

    www.witpress.com, ISSN 1755-8336 (on-line) WIT Transactions on State of the Art in Science and Engineering, Vol 63, © 2013 WIT Press

  • 68 EMERGING TOPICS IN HEAT TRANSFER

    the turbine blade tip and the region near the tip. A common way to cool the blade tip is to adopt internal cooling by designing serpentine (two-pass, three-pass, or multi-pass) channels with a 180° turn/bend inside the blade (as shown in Fig. 1). Taking advantage of impinging and turning effects, the tip can be cooled to a cer-tain extent. To augment forced convection, advanced methods of enhancing the internal convective cooling for the tip region are required. The blade lifetime and reliability will then be improved. Several publications reviewing the gas turbine heat transfer and cooling technology research can be found [1–7].

    It is well recognized that many heat transfer augmentation devices (e.g. fi ns, ribs, pins, dimples, and protrusions) can be used to improve the intensity of heat transfer. Dimples and protrusions are arrays of extended surfaces that are indented or protruded on primary surfaces or smooth walls in a channel, as shown in Figs 2c and 3d. They are often spherical in shape. Like ribs and pins, it is expected that dimples and protrusions can generate strong vortices when they are placed in a fl ow and then higher turbulence is produced around them. Many previous research works have shown that pins, dimples, and protrusions can provide substantial heat transfer enhancement in confi ned low aspect ratio channels. Although it is well known that ribs and pins can signifi cantly augment heat transfer over primary or smooth surfaces, the augmentation is always penalized by the large additional pressure loss. For example, Chyu [8] experimentally measured mass/heat transfer enhancement of up to 4.0 for circular staggered pins at high Reynolds numbers but with a friction coeffi cient increase of around 70 compared with that of a fully developed smooth fl ow channel. Bailey and Bunker [9] obtained heat transfer enhancement of up to 3.6 for ribbed channels with very high blockage ratios

    Figure 1: A typical serpentine passage inside a turbine blade.

    Figure 2: Heat transfer augmentation devices for a smooth surface.

    www.witpress.com, ISSN 1755-8336 (on-line) WIT Transactions on State of the Art in Science and Engineering, Vol 63, © 2013 WIT Press

  • HEAT TRANSFER ENHANCEMENT OF A GAS TURBINE BLADE-TIP WALL 69

    (rib height to channel height) of approximately 27.5–47.5% over a smooth channel without ribs. However, this enhancement was accompanied by a friction coeffi -cient increase of as much as 65. By comparing several types of heat transfer aug-mentation techniques for internal cooling of turbine airfoils, Ligrani et al. [10] concluded that except for swirl chambers, dimples exhibited better overall perfor-mance than pins, rib turbulators, and other surface roughnesses.

    During recent years, various pins, dimples, or protrusions have received much attention for enhancing heat transfer in internal cooling passages of turbomachin-ery. Numerous experimental and numerical studies of heat transfer and pressure drop for shaped pins, dimples, or protrusions are available [11–22]. Metzger et al. [11] studied the developing heat transfer in rectangular ducts having short pin-fi n arrays. They found that the heat transfer coeffi cient gradually increased to the fi rst three or four rows followed by a gradual decrease through the remaining rows. Lau et al. [12] experimentally studied the effect of the pin confi guration on the local endwall heat/mass transfer in pin-fi n channels. They observed that the decrease of the streamwise pin space led to an increase of the endwall heat/mass transfer. Chyu et al. [13] reported that the pin-fi n heat transfer was approximately 10–20% higher than the endwall heat transfer. Goldstein et al. [14] found that the stepped-diameter circular pin-fi n array provided a higher mass transfer coeffi cient and a smaller pres-sure loss than a uniform-diameter circular pin-fi n array. Chyu et al. [15] experimen-tally studied the heat transfer on staggered dimpled surfaces using the transient liquid crystal method. They reported that the heat transfer ratios everywhere on the dimpled surface were higher than those of the smooth channels, and the largest fac-tor of heat transfer enhancement was more than 2.5 located downstream the area of the dimples. Moon et al. [16] used a similar experimental method to investigate rectangular channels with dimples imprinted on one wall. Results showed that a heat transfer enhancement of 2.1 times could be achieved with approximately 1.6–2.0 times pressure drop penalty compared with the smooth surfaces. Moon and Lau [17] experimentally reported average heat transfer coeffi cients on a wall with concave and cylindrical dimples in a square channel. They found that the cylindri-cal dimples offered higher heat transfer enhancement with lower pressure drop than the concave dimples with identical diameter and depth. Griffi th et al. [18] measured averaged Nusselt numbers in a rotating rectangular channel with dimples placed on both sides. They found that the rotation could augment the heat transfer on dimpled surfaces, especially on the trailing dimpled surface toward which the colder fl uid core migrates due to the Coriolis forces. Ligrani et al. [19] performed fl ow visual-ization, pressure, and velocity measurements on the fl ow structure of a dimpled wall. They observed a primary vortex pair shed periodically from the center of each dimple, and two additional secondary vortex pair formed near the spanwise edges of each dimple. Mahmood et al. [20] and Ligrani et al. [21] measured local and spatially Nusselt number for the dimpled surface with and without protrusions on the opposite wall. Results showed that for the dimple-protrusion channel, Nusselt numbers were augmented considerably because of the added vortical, secondary fl ow structures and fl ow unsteadiness produced by the protrusions. Hwang et al. [22] used transient Thermochromic liquid crystal (TLC) technique to measure the

    www.witpress.com, ISSN 1755-8336 (on-line) WIT Transactions on State of the Art in Science and Engineering, Vol 63, © 2013 WIT Press

  • 70 EMERGING TOPICS IN HEAT TRANSFER

    local heat transfer coeffi cients on the dimple or protrusion walls at low Reynolds numbers varying from 1,000 to 10,000. They found that a double protrusion chan-nel wall provided the highest average heat transfer rate associated with the highest pressure drop. At low Reynolds number of 1,000 the heat transfer enhancement factor was up to 14. However, in the high Reynolds number range the double pro-trusion channel wall offered lower performance factor than other cases: double dimple wall, simple protrusion wall, simple dimple wall. Park et al. [23] predicted turbulent structures above a dimpled surface using FLUENT with the realizable k–e model without wall functions. They claimed that due to the advection of reattaching and recirculating fl ow within the dimple cavities as well as the strong instantaneous secondary fl ow and mixing, the vortex pair contains augmented magnitudes of eddy diffusivity for momentum and heat.

    There have been many studies on multipass (mostly, two pass) channel fl ow fi elds and heat transfer. Both experimental measurements and numerical simula-tions show that low heat transfer associated with fl ow separations always occur at the corners in the turn region and downstream the turn along the inner wall, as depicted in Fig. 3. Particle image velocimetry (PIV) measurements in [24] show a strong Dean-type secondary fl ow and a large separation bubble on the inner wall downstream of the bend exit. The secondary fl ow consisting of two counter rotat-ing vortices caused a strong impingement of the fl ow on the outer walls at the bend exit. Schabacker et al. [25] later measured fl ow fi eld in a similar ribbed channel to show the interaction between the turbulator-induced secondary fl ow and the bend-induced secondary fl ow. Son et al. [26] also measured the fl ow fi eld and heat transfer inside a two-pass square channel with a smooth wall and a 90° turbulator-roughened wall, indicating that the fl ow impingement is the primary factor for the heat transfer enhancement rather than the fl ow turbulence level itself. Therefore, to modify or improve the fl ow structure with low heat transfer involved, properly designed guide vanes/ribs are suggested to be placed in appropriate regions.

    However, there have been only a few studies on effects of guide vanes (turning ribs) inside serpentine channels published in the open literature. Rathjen et al. [27] studied mass/heat transfer in a smooth two-pass channel with a 90° guide vane. The intention was to avoid the fl ow separation zone. Liou et al. [28,29] experimen-tally studied the effects of the number of guide vanes on the 3D fl ow fi eld in a 60° curved combustor inlet. It was found that by adding three guide vanes, the fl ow

    Figure 3: Conceptual fl ow pattern around a 180° turn.

    www.witpress.com, ISSN 1755-8336 (on-line) WIT Transactions on State of the Art in Science and Engineering, Vol 63, © 2013 WIT Press

  • HEAT TRANSFER ENHANCEMENT OF A GAS TURBINE BLADE-TIP WALL 71

    separation in the curved combustor could be eliminated completely. In most regions with increasing number of guide vanes, the maximum radial mean veloc-ity, difference between radial and spanwise normal stress, and the turbulent kinetic energy were decreased. Rao et al. [30, 31] and Babu et al. [32] investigated the effects of guide vanes on pressure drop in smooth or roughened channels with a 180° bend. Experimental results showed that pressure losses were signifi cantly affected by the shape and position of the guide vanes. The overall pressure drop could be decreased by as much as 14–20% if properly shaped extended guide vanes were located in the center of the bend. Luo and Razinsky [33] performed numerical simulation of the turbulent fl ows inside several 2D and 3D 180° U ducts with and without guide vanes by a Reynolds-Average-Navier-Stokes (RANS) method. Results showed that the combined vane and uniform cross-sectional area led to much weaker secondary-fl ow vortices and smaller separation, which accounted for a substantial reduction in pressure loss.

    For blade-tip heat transfer, little information is available. In the earlier study by Han et al. [34], mass/heat transfer data of smooth tip surface (in the paper named outer wall in the turn) in smooth and turbulated square two-pass channels were mea-sured by the naphthalene sublimation technique. The typical averaged tip heat trans-fer of smooth and ribbed channels at Reynolds number of 30,000 is about 1.8 and 2.5 times larger than the fully developed duct turbulent heat transfer, respectively. Note that for the turbulated two-pass channel, only the inlet and outlet channels were turbulated while the tip wall was kept smooth. The turbulator height-to-hydraulic diameter ratios were 0.063 and 0.094. Wagner et al. [35,36] measured the heat trans-fer in nonrotating and rotating multipass channels with and without turbulators placed in straight sections. It was found that the heat transfer in the turn was approx-imately two and three times larger than the fully developed duct turbulent heat trans-fer for the nonrotating and rotating conditions, respectively. The turbulators produced about 10% higher augmentation for the averaged tip heat transfer. In their studies, the turbulator height-to-hydraulic diameter ratio was 0.1 and the baseline Reynolds number and rotation number were 25,000 and 0.24, respectively.

    For serpentine channels with 180° turn, turbulent mixing can be strengthened effectively, and therefore, the heat transfer can be augmented on the concerned sur-faces. Bunker [37] presented a method to increase convective heat fl ux on an inter-nal cooled blade-tip cap, where arrays of shaped pins were placed. It was found that the effective heat transfer coeffi cient could be increased up to a factor of 2.5 while the tip turn pressure drop was negligible compared with that of a smooth surface. From the aforementioned articles, it was clear that most previous studies were con-cerned with the heat transfer on the leading or/and trailing walls of the two-pass channels, and very limited information is available for tip walls. Thus, it is desirable to explore effective cooling techniques for the internal tip, and to present more details on the heat transfer enhancement. For these reasons, the main objective of the present chapter is to provide a comprehensive summary of the heat transfer enhance-ment over the tip-wall in a rectangular two-pass channel at high Reynolds numbers, up to 600,000. Typical results are provided to show the tip cooling performance for a variety of cases. More details can be found in recently published papers [38–46].

    www.witpress.com, ISSN 1755-8336 (on-line) WIT Transactions on State of the Art in Science and Engineering, Vol 63, © 2013 WIT Press

  • 72 EMERGING TOPICS IN HEAT TRANSFER

    2 Physical Models of Eight Kinds of Tip-Cooling Concepts

    The geometrical models considered in this chapter are schematically shown in Fig. 4. The two-pass channels have rectangular cross section with an aspect ratio of 1:2 with a hydraulic diameter of 93.13 mm. The full tip-wall cap section is 139.7 mm × 165.1 mm, and the tip clearance (the distance between divider to tip cap) is 88.9 mm. The lengths of the inlet channels (fi rst pass) and the outlet chan-nels (second pass) are about ten hydraulic diameters. It is worthwhile to note that the considered models of the rectangular two-pass channels are similar to those in the experiments by Bunker [37], while the internal tip cap is augmented by circular pins, hemispherical dimples, or protrusions.

    Case 0: As shown in Fig. 4a, no augmentation devices are placed on the tip wall, fi rst pass, or second pass. This means that all the walls are smooth. A smooth-tip two-pass channel is used as a baseline for performance comparison.

    Case 1F: As shown in Figs 4b and g, the internal tip cap is almost completely occupied by a full array of circular pin-fi ns. The pin arrangement is shown in Fig. 4g. The pins have a height of 8.128 mm and a diameter of 4.064 mm. The streamwise pitch is 21.117 mm (y direction) and the spanwise pitch is 12.192 mm (z direction). The total number of pin fi ns is 165. The tip (including endwall and pin-fi ns) surface wetted area enhancement is 1.74 compared with the smooth-tip surface area. In order to provide a similar model to that used in Bunker’s experi-ments [37], in which a uniform heat fl ux was prescribed on the external smooth tip-wall, a solid plane tip with a certain thickness is placed below the internal pin-fi nned tip cap and a uniform heat fl ux is supplied there. The turbulent convec-tion between the fl uid and solid, and heat conduction within the solid parts are

    Figure 4: Sketches of seven physical models.

    www.witpress.com, ISSN 1755-8336 (on-line) WIT Transactions on State of the Art in Science and Engineering, Vol 63, © 2013 WIT Press

  • HEAT TRANSFER ENHANCEMENT OF A GAS TURBINE BLADE-TIP WALL 73

    conjugated in the computations [43]. In this case, the pin fi ns are made of aluminum with the density of 2,719 kg/m3 and the thermal conductivity of 202.4 W/(m K).

    Case 1P: As shown in Figs 4b and h, a partial array of circular pin fi ns is sym-metrically arranged close to both sides of leading/trailing walls. Except for the distributions, other parameters of the channels and pins are completely identical to that of Case 1F. The area enhanceme nt factor is 1.21.

    Case 1FM: This case is similar to the Case 1F except that the pin fi ns are made of insulating material (Renshape) with a density of 1,800 kg/m3 and thermal con-ductivity of 1 W/(m K). Thus, the area enhancement factor is 1.0, that is, no effec-tive heat transfer area increase is provided. Other materials of the pin fi ns have also been considered, see [41].

    Case 2: As shown in Fig. 4c, an array of dimples is pressed on the internal tip cap. The dimples have a height (depth) of 2.032 mm and a print diameter of 4.064 mm. The arrangement is the same as the pin arrangement of Case 1F and hence the number of dimples is identical. The area enhancement factor is 1.092.

    Case 3: As shown in Fig. 4d, an array of protrusions is located on the internal tip cap. The layout and dimensions of the spherical protrusions are identical to those of the dimples except that the protrusions are located above the internal tip-cap surface like fl ow obstacles. Accordingly, the protruded tip has the same are a enhancement factor (i.e. 1.092).

    Case 4: As shown in Fig. 4e, four guide ribs are placed in the turn region (due to the down view of the 3D geometry only two guide ribs are shown in the fi gure, for the side view of geometry, the ribs are symmetrically placed at the bottom and on the upper walls as shown in Fig. 4i). The ribs have a height of 12.7 mm and a thickness of 5.08 mm. Thus, the ribs have a cross-sectional blockage ratio (2e/H) of 0.182. The tip wall is still kept small.

    Case 5: As shown in Fig. 4f, two arc-like guide ribs are placed in the turn region. The ribs have the same height and thickness as Case 4.

    In reality, it might be hard to manufacture the pin fi ns and fi x them to the inter-nal tip surface as perfect circular cylinders. In the experiments by Bunker [37] this was also the case, which means that the pin fi ns had some base fi llets closest to the tip surface. This will be commented on later.

    This chapter aims to summarize the heat transfer enhancement and pressure drop of two-pass channels, and then compare the overall performance to provide useful information for blade-tip cooling-design concepts.

    3 Computational Details

    3.1 Selection of turbulence model

    The selection of a turbulence model for the simulations requires consideration of computational cost, predicted fl ow phenomena, and acceptable accuracy. This chapter mainly concerns tip-wall heat transfer, and therefore the agreement between the calculated Nusselt number and experimental data is the main crite-rion for selecting turbulence models. Six different turbulence models, that is, the

    www.witpress.com, ISSN 1755-8336 (on-line) WIT Transactions on State of the Art in Science and Engineering, Vol 63, © 2013 WIT Press

  • 74 EMERGING TOPICS IN HEAT TRANSFER

    standard k–e model, the Renormalization Group (RNG) k–e model, the realizable k–e model, the shear stress transport (SST) k–w model, the v2f model, and the Reynolds stress model (RSM) were chosen to simulate the turbulent heat transfer of the smooth two-pass channel (as shown in Fig. 4a). Figure 5 compares the experimentally obtained and the predicted average Nusselt number at a Reyn-olds number of 200,000 with the different turbulence models. From this fi gure, the RNG k–ε model results approach the experimental data slightly better than the other tested turbulence models. The smallest difference of 14.7% is found by the k–e RNG model and the largest difference of 48% is found by the standard v2f model. Actually, the three k–e models provide very similar results. The test computations showed that by using the realizable k–e model, the CPU time can be shortened and the convergence behavior is better than for the other two models, especially for computing cases of pin-fi nned channels. The computed fi nal results, which will be presented in this chapter, are all based on the realizable k–e turbu-lence model. The corresponding governing equations are presented in the follow-ing sections and may also be found in the FLUENT documentation [47].

    Standard wall functions for the realizable k–e model are applied on the walls for the near-wall treatment because the Reynolds numbers are high and the geometri-cal models are complicated. Most of the y+ values on the tip walls lie between 15 and 50.

    3.2 Grid dependence

    The preprocessor software GAMBIT was used to generate the grids. Figure 6 shows typical surface grids of Cases 1, 3, and 5. Because of the complex geome-tries, a multiblock grid technique was used to generate grids by dividing the whole domain into several subdomains. In the turn region due to the many small circular

    Figure 5: Comparison of predicted Nusselt numbers by six turbulence models (Re = 200,000). Experimental data from [37].

    www.witpress.com, ISSN 1755-8336 (on-line) WIT Transactions on State of the Art in Science and Engineering, Vol 63, © 2013 WIT Press

  • HEAT TRANSFER ENHANCEMENT OF A GAS TURBINE BLADE-TIP WALL 75

    pins/dimples/protrusions or guide ribs, an unstructured grid has to be fi lled into the domain. This domain occupies about 95% of all cells.

    To ensure the accuracy and reliability of the numerical results, several careful checks of the grid effect of the numerical solutions had to be carried out before the fi nal calculations. Several candidate grid systems with large number of grid points were considered. For example with the pin-fi nned channel, four grid systems, that is, 989,996 cells, 1,889,055 cells, 2,494,201 cells, and 3,265,705 cells at a Reyn-olds number of 200,000 were tested. It was found that the relative deviation of both Nusselt numbers and pressure drops between 2.49M cells and 3.26M cells was 3.33% and 0.08%, respectively. Thus, to save computer resources and keeping a balance between computational economy and prediction accuracy, the grid with 2.49M cells has been chosen. Similarly for the other cases, grid systems of around 2.1M–2.4M cells have been chosen, respectively. These simulations are performed on a PC with two CPUs having a frequency of 3.0 GHz and a core memory of 8G. Typical running times for computation of one case are about 12 and 48 hours for the smooth-tip channel and the augmented tip channels, respectively.

    3.3 Boundary conditions

    Although the heat transfer on the leading and trailing walls is important for gas turbine blade design, the tip-wall heat transfer is a major concern. Therefore, in order to approach the experimental conditions by Bunker [37], in which a uniform heat fl ux was created by a heater, a constant heat fl ux is prescribed on the bottom walls while the remaining walls are assumed to be adiabatic. No-slip velocity conditions are applied at all walls. Uniform inlet velocity and tempera-ture, that is, 300 K, are assigned at the inlet and an outfl ow condition is chosen at the outlet.

    The fl uid is assumed to be incompressible with constant thermal physical properties and the fl ow is assumed to be three dimensional, turbulent, steady, and nonrotating. Although for augmented straight passages the fl ows might behave unsteady, it is believed that, for the present augmented-tip two-pass channels, unsteady fl ow will not occur as the pins, dimples, protrusions, and guide ribs are assumed to stabilize the fl ow to some extent. The working fl uid is dry air. The minimum convergence criterion for continuity, momentum quantities error, and k and e equations is 10–4, whereas it is 10–7 for the energy equation.

    Figure 6: Typical surface grids.

    www.witpress.com, ISSN 1755-8336 (on-line) WIT Transactions on State of the Art in Science and Engineering, Vol 63, © 2013 WIT Press

  • 76 EMERGING TOPICS IN HEAT TRANSFER

    4 Fluid Flow and Heat Transfer Characteristics

    4.1 Definitions of friction factor and Nusselt number

    The pressure drop is transferred to the Fanning friction factor f which is defi ned as follows:

    f

    p

    u

    D

    L= ⋅

    Δ2r i

    2h

    (1)

    where ui is inlet velocity, L is the two-pass channel total length.The overall/averaged Nusselt number can be calculated in the following way.

    The local Nusselt number of every cell vertex is fi rst calculated as

    Nu i

    q

    T i T

    D( ) =

    −⋅w

    f

    h

    ( ) l (2)

    where Tf is the mass-weighted average fl uid temperature between the inlet and outlet fl uid temperatures, and T(i) is the local surface temperature. The overall/averaged Nusselt number is determined by area-weighted averaging of all local Nusselt numbers on the bottom wall, which is expressed as follows:

    NuA i Nu i

    A i= ∑

    ∑( ) ( )

    ( ) (3)

    4.2 Model validation

    To validate the computational approach, the turbulent heat transfer in the smooth two-pass channel was computed. The averaged Nusselt numbers and pressure drop of Case 0 are compared and listed in Table 1. It is found that the largest deviation in the Nusselt number between the simulations by the Realizable k–ε turbulence model and the experimental data is less than 15% and the smallest deviation is about 7%. In the work by Bunker [37], the experimental uncertainty in the heat transfer coeffi cient was between 8% and 15%. The decent agreement between the predicted and tested results shows the reliability of the physical model. Thus, the validation and reliability of the computational approach were ensured.

    Table 1: Comparison of Nusselt numbers and pressure drops.

    Re = 200,000 Re = 310,000 Re = 440,000

    Nu This work 412.95 562.61 718.72Bunker [37] 483.34 620.82 770.85

    Deviation, % 14.6% 9.4% 6.7%

    Δp, Pa This work 978.86 2,216.24 4,252.86Bunker [37] 1,186.44 2,758.47 4,998.82

    Deviation, % 17.5% 19.7% 14.9%

    www.witpress.com, ISSN 1755-8336 (on-line) WIT Transactions on State of the Art in Science and Engineering, Vol 63, © 2013 WIT Press

  • HEAT TRANSFER ENHANCEMENT OF A GAS TURBINE BLADE-TIP WALL 77

    4.3 Flow and temperature fields

    To facilitate a better understanding of the enhanced heat transfer over the tips, velocity vectors and temperature contours are presented. As an example, Fig. 7 shows the cross-sectional velocity vectors of Case 0 and Case 1F. It can be seen that for both channels, high-momentum fl uid enters the turn from the inlet chan-nel and impinges on the outer walls. Before the sharp turn, the velocity profi les are fl at. Upon entering the turn, the fl ow accelerates near the inner wall while it decelerates near the outer wall. This distribution is reversed at the beginning of the second channel. When the coolant travels through the 180° turn of the two-pass channels, areas of impingement, separation, and recirculation are created. Because of the inability of the fl ow to follow the turn, a separation bubble appears down-stream of the tip of the divider wall followed by a reattachment. Two circulating regions occur at the fi rst-pass channel corner and the second-pass corner, respec-tively. As the fl uid fl ows through the 180° turn, the centrifugal forces arising from the curvature and pressure difference (low pressure at the inner wall, while high pressure at the outer wall) produce a pair of counter-rotating vortices in the turn. These vortices are signifi cantly strong and are responsible for the transport of cold fl uid from the core toward the outer wall. For the smooth-tip channel, only vortices remain on the upstream side of the second pass. For the pin-fi nned tip channel, the cores of the pair of counter-rotating vortices in the turn move downwards close to the pin-fi ns, and the zone of separation is larger than that of the smooth-tip chan-nel. At the upstream side of the second pass, both the vortices and the separation bubble exist. The vortices force the cold fl uid to impinge toward the pin fi ns and then induce turbulent mixing of the coming cold fl uid with the hot fl uid near the pin-fi ns and endwall. At this point, the heat transfer over the tip wall is increased due to the continuous mixing process.

    Figure 7: Sectional fl ow fi elds at Re = 200,000 of Case 0 and Case 1F.

    www.witpress.com, ISSN 1755-8336 (on-line) WIT Transactions on State of the Art in Science and Engineering, Vol 63, © 2013 WIT Press

  • 78 EMERGING TOPICS IN HEAT TRANSFER

    Figure 8 shows the tip-wall temperature contours of Case 0 and Case 1F. It can be observed that due to the cold fl uid impinging toward the tip wall, the tempera-ture of the fi rst tip part is lower than that of the second tip part. By comparing Figs 8a and b, it is found that a much lower temperature region occurs at the bottom walls of the pin-fi nned tip channels due to the cold fl uid impingement and pin-fi n cross-fl ow. Besides, through the heat conduction in the pins and tips, a more uni-form temperature is observed in the pin-fi nned tip channels compared with the smooth-tip channel. It is then expected that much higher Nusselt numbers and hence heat transfer are produced by the pin-fi nned tip channels. Similar distribu-tions for the other considered cases are not presented.

    4.4 Pressure drop and heat transfer

    The surface-averaged Nusselt number and inlet-to-outlet pressure drop for all Reynolds numbers are summarized in Fig. 9. Concerning heat transfer, the heat transfer coeffi cients of Cases 1–5 are higher than that of Case 0. Among them, Case 1F offers the largest heat transfer followed by Case 1P. The averaged heat transfer coeffi cients of Case 2 and Case 3 are similar, and at high Reynolds num-bers Case 5 offers higher heat transfer than Case 2 and Case 3. This indicates that a tip with pins can provide better heat transfer than a tip with dimples or protrusions. Case 1FM offers 10–60% higher heat transfer than Case 0. This indicates that even if the pins are made of an insulating material, the tip heat transfer can be enhanced by the pins especially at low Reynolds numbers.

    For the pressure loss, the largest pressure drop is produced by Case 4, followed by Case 1F. Similar pressure drops are produced by Cases 1P, 2, and 3. The pres-sure drop of Case 5 is smaller than that of Case 0. This indicates that the pressure drop will be reduced when the guide ribs are designed properly otherwise the pressure drop will be severely increased. For the same geometry, the material property does not affect the pressure loss.

    Figure 8: Temperature contours on the tip, Re = 200,000: (a) Case 0; (b) Case 1F.

    www.witpress.com, ISSN 1755-8336 (on-line) WIT Transactions on State of the Art in Science and Engineering, Vol 63, © 2013 WIT Press

  • HEAT TRANSFER ENHANCEMENT OF A GAS TURBINE BLADE-TIP WALL 79

    Figure 10 provides the averaged Nusselt number and friction factor as normal-ized by the corresponding values for fully developed turbulent fl ow and heat trans-fer based on inlet channel conditions (identical Reynolds numbers). The values for Nu0 and f0 of fully developed channel fl ow are obtained from Nu0 = 0.023 Re

    0.8Pr0.3 and f0 = (0.79ln Re–1.64)

    –2/4. It is found that the largest heat transfer enhancement is about a factor of 3.6, and the friction factor is increased by around 4–6 times.

    Figure 9: Nusselt number and friction factor.

    www.witpress.com, ISSN 1755-8336 (on-line) WIT Transactions on State of the Art in Science and Engineering, Vol 63, © 2013 WIT Press

  • 80 EMERGING TOPICS IN HEAT TRANSFER

    Examples of typical distributions of the local heat transfer enhancement of Case 1F, Case 2, and Case 5 at Re = 200,000 are plotted in Fig. 11. It is distinctly observed that slightly higher local heat transfer enhancement is produced at the fi rst-pass tip region, while at the second-pass tip region much higher local heat transfer enhancement is achieved. Especially by adding the pins on the tip cap, the enhancement factor of the second-pass tip region lies between 2.5 and 4.5.

    Figure 10: Normalized Nusselt number and friction factor.

    www.witpress.com, ISSN 1755-8336 (on-line) WIT Transactions on State of the Art in Science and Engineering, Vol 63, © 2013 WIT Press

  • HEAT TRANSFER ENHANCEMENT OF A GAS TURBINE BLADE-TIP WALL 81

    Figure 11: Profi les of local heat transfer enhancement.

    www.witpress.com, ISSN 1755-8336 (on-line) WIT Transactions on State of the Art in Science and Engineering, Vol 63, © 2013 WIT Press

  • 82 EMERGING TOPICS IN HEAT TRANSFER

    5 Overall Comparisons of Tip-Cooling Concepts

    The augmented two-pass channels provide higher Nusselt number associated with slightly higher pressure drop. Accordingly, it is essential to compare the heat trans-fer enhancement performance of the two-pass channels. Figure 12 presents a com-parison of the globally averaged Nusselt number ratio divided by the normalized friction factor ratio for the three channels. Nu/Nu0/(f/f0) parameter is referred to as the Reynolds analogy performance parameter, and Nu/Nu0/(f/f0)

    1/3 parameter is to provide a heat transfer augmentation quantity. It relates the heat transfer aug-mentation Nu/Nu0 and the friction factor increase f/f0 at the same ratio of mass fl ux in a channel with augmentation devices to a channel with smooth surfaces. From Fig. 12, it is found that compared to the smooth channel, all the channels with augmented devices provide higher values of the parameter Nu/Nu0/(f/f0) and Nu/Nu0/(f/f0)

    1/3 at all Reynolds numbers from 100,000 to 600,000. The pinned-tip two-pass channel, Case 1F, exhibits the best performance, followed by Case 5 at high Reynolds numbers.

    Figure 13 presents a comparison of the heat transfer coeffi cient versus the required pumping power for the four channels. From this fi gure, it is found that at identical required pumping power the pinned-tip channels (Case 1F and Case 1P) and Case 5 at high Reynolds number offer a higher heat transfer coeffi cient, and thereby higher heat transfer enhancement. This indicates that the use of pins on the tip or adding guide ribs in the turn region could increase the heat transfer intensity signifi cantly associated with low additional pressure losses.

    Figure 12: Normalized Nusselt number ratio and friction factor ratio.

    www.witpress.com, ISSN 1755-8336 (on-line) WIT Transactions on State of the Art in Science and Engineering, Vol 63, © 2013 WIT Press

  • HEAT TRANSFER ENHANCEMENT OF A GAS TURBINE BLADE-TIP WALL 83

    Figure 14 provides an alternative comparison of the heat transfer enhancement of the augmented tips. The Nusselt number ratio of the tips of the augmented chan-nels over the smooth channel is normalized by the active surface area enhancement factor of the tips. Since the heat transfer enhancement value is mostly attributed by the active surface area increase obtained from the augmented geometry, it is essen-tial to evaluate the overall performance disregarding the area increase to describe

    Figure 12: Continued

    Figure 13: Heat transfer coeffi cient versus pumping power.

    www.witpress.com, ISSN 1755-8336 (on-line) WIT Transactions on State of the Art in Science and Engineering, Vol 63, © 2013 WIT Press

  • 84 EMERGING TOPICS IN HEAT TRANSFER

    the ability of augmented heat transfer devices over the primary surface. From the fi gure, it can be clearly seen that the tips with hemispherical dimples or protru-sions, Case 2 and Case 3, are superior to the tip with pin-fi ns when they are used to augment the smooth tip heat transfer at low Reynolds numbers. However, at high Reynolds number, Case 5 provides the highest value of this ratio. On the other hand, for practical operation, minimizing blade weight is an objective for design-ing rotating blades. The added weight implies possible larger stress, which results in reduced reliability and life.

    6 Concluding Remarks

    In order to explore the effective cooling technology for gas turbine blade tips, attempts have been tried to improve the tip heat transfer. In the presented investi-gations, scaled models of a rectangular two-pass channel with various augmented tip-caps have been simulated numerically by so-called Computational Fluid Dynamics (CFD) technique. The main conclusions are summarized as follows.

    1. By adding pins/dimples/protrusions on the internal tip, the tip heat transfer can be increased about 2.0–3.0 times associated with less than 10% higher pressure loss. The intensity of heat transfer enhancement depends upon pins/dimples/protrusions confi guration and arrangement.

    2. Using augmentation devices, the heat transfer at the side edge regions can be improved, especially at the second-pass tip side region.

    3. The larger the thermal conductivity of the pins is, the higher is the tip heat transfer. At low Reynolds numbers, the tip heat transfer is enhanced even by using insulating pins with a low thermal conductivity.

    Figure 14: Nusselt number ratio normalized by the active area ratio.

    www.witpress.com, ISSN 1755-8336 (on-line) WIT Transactions on State of the Art in Science and Engineering, Vol 63, © 2013 WIT Press

  • HEAT TRANSFER ENHANCEMENT OF A GAS TURBINE BLADE-TIP WALL 85

    4. Base fi llets may provide a small additional heat transfer increase without affect-ing the pressure drop signifi cantly.

    5. The presence of guide ribs in the turn regions can improve the tip heat transfer and the pressure loss might be reduced if the ribs are properly designed and placed.

    6. Pins are preferable devices to augment the tip heat transfer when the added tip weight is acceptable for the mechanical design.

    7. While disregarding the active area ratio or considering added weight ratio, it is found that the arc-like guide ribs have the best potential to improve the tip cooling.

    Acknowledgments

    The research has been funded by the Swedish Energy Agency, Siemens Industrial Turbomachinery AB and Volvo Aero Corporation through the Swedish research program TURBO POWER, the support of which is gratefully acknowledged. The authors also would like to thank Drs. Lieke Wang and Esa Utriainen, Siemens Industrial Turbomachinery AB, Sweden for excellent technical collaboration.

    Nomenclature

    A tip-wall surface area Greek symbolsD Diameter of pin fi ns e Rate of energy dissipationDh hydraulic diameter l fl uid thermal conductivity E height of guide ribs µ fl uid dynamic viscosity F Fanning friction factor r fl uid density h heat transfer coeffi cient Δp pressure drop H height of pin fi ns L length of two-pass channel SubscriptsNu Nusselt number 0 fully developed fl ow channelP Pumping power f fl uidqw wall heat fl ux i inletRe Reynolds number, Re = r ui Dh/µ o outletui inlet velocity s smooth-tip channelW channel height

    References

    [1] Han, J.C., Dutta, S. & Ekkad, S.V., Gas Turbine Heat Transfer and Cooling Technology, Taylor & Francis: New York, 2000.

    [2] Goldstein, R.J., Heat Transfer in Gas Turbine Systems, Annals of the New York Academy of Sciences: New York, 2001.

    www.witpress.com, ISSN 1755-8336 (on-line) WIT Transactions on State of the Art in Science and Engineering, Vol 63, © 2013 WIT Press

  • 86 EMERGING TOPICS IN HEAT TRANSFER

    [3] Sunden, B. & Faghri, M., Heat Transfer in Gas Turbines, WIT Press: UK, 2001.

    [4] Han, J.C., Recent studies in turbine blade cooling. Int. J. Rotating Machinery, 10(6), pp. 1–15, 2004.

    [5] Sunden, B. & Xie, G.N., Gas turbine blade tip heat transfer and cooling: a literature survey. Heat Transfer Engineering, 31(7), pp. 527–554, 2010.

    [6] Bunker, R.S., A review of turbine blade tip heat transfer. Annals of the New York Academy of Sciences, ed. R.J. Goldstein, New York Academy of Sciences: New York, pp. 64–79, 2000.

    [7] Bunker, R.S., Axial turbine blade tips: function, design and durability. AIAA J. Propulsion and Power, 22(2), pp. 271–285, 2006.

    [8] Chyu, M.K., Heat transfer and pressure drop for short pin-fi n arrays with pin-endwall fi llet. ASME J. Heat Transfer, 112, pp. 926–932, 1990.

    [9] Bailey, J.C. & Bunker, R.S., Heat transfer and friction in channels with very high blockage 45-degree staggered turbulators. Proceedings of ASME Turbo Expo 2003, Atlanta, USA. paper no. GT2003-38611.

    [10] Ligrani, P.M., Oliveira, M.M. & Blaskovich, T., Comparison of heat transfer augmentation techniques. AIAA Journal, 41, pp. 337–372, 2003.

    [11] Metzger, D.E., Berry, R.A. & Bronson, J.P., Developing heat transfer in rect-angular ducts with staggered arrays of short pin fi ns. ASME J. Heat Transfer, 104, pp. 700–706, 1982.

    [12] Lau, S.C., Kim, Y.S. & Han, J.C., Local endwall heat/mass distributions in pin fi n channels. AIAA J. Thermophysics, 1(4), pp. 365–372, 1987.

    [13] Chyu, M.K., Hsing, Y.C., Shih, T.I.P. & Natarajan, V., Heat transfer contribu-tions of pins and endwall in pin-fi n arrars: effect of thermal boundary condi-tion modeling. ASME J. Turbomachinery, 121, pp. 257–263, 1999.

    [14] Goldstein, R.J., Jabbari, M.Y. & Chen, S.B., Convective mass transfer and pressure loss characteristics of staggered short pin-fi n arrays. Int. J. Heat Mass Transfer, 37(Suppl 1), pp. 149–160, 1994.

    [15] Chyu, M.K, Yu, Y., Ding, H., Downs, J.P. & Soechting, F., Concavity enhanced heat transfer in an internal cooling passages. Proceedings of GT1997, ASME Turbo 1997, paper no. 97-GT-437.

    [16] Moon, H.K., O’Connell, T. & Glezer, B., Channel height effect on heat trans-fer and friction in a dimpled passage. ASME J. Eng Gas Turbine Power, 122, pp. 307–313, 2000.

    [17] Moon, S.W. & Lau, S.C., Turbulent heat transfer measurement on a wall with concave and cylindrical dimples in a square channel. Proceedings of GT2002, ASME Turbo 2002, paper no. GT-2002-30208.

    [18] Griffi th, T.S., Al-Hadhrami, L. & Han, J.C., Heat transfer in rotating rect-angular cooling channels with dimples. ASME J. Turbomachinery, 125, pp. 555–564, 2005.

    [19] Ligrani, P.M., Harrison, J.L., Mahmood, G.I. & Hill, M.L., Flow struc-ture due to dimple depression on a channel surface. Physics of Fluids, 13, pp. 3442–3451, 2001.

    www.witpress.com, ISSN 1755-8336 (on-line) WIT Transactions on State of the Art in Science and Engineering, Vol 63, © 2013 WIT Press

  • HEAT TRANSFER ENHANCEMENT OF A GAS TURBINE BLADE-TIP WALL 87

    [20] Mahmood, G.I., Sabbagh, M.Z. & Ligrani, P.M., Heat transfer in a channel with dimples and protrusions on opposite walls. AIAA J. Thermophysics and Heat Transfer, 15(3), pp. 275–283, 2002.

    [21] Ligrani, P.M., Mahmood, G.I., Harrison, J.L., Clayton, C.M. & Nelson, D.L., Flow structure and local Nusselt number variations in a channel with dimples and protrusions on opposite walls. Int. J. Heat Mass Transfer, 44, pp. 4413–4425, 2001.

    [22] Hwang, S.D., Kwon, H. & Cho, H.H., Heat transfer with dimple/protrusion arrays in a rectangular duct with a low Reynolds number range. Int. J. Heat Fluid Flow, 29, pp. 916–926, 2008.

    [23] Park, J., Desam, P.R. & Ligrani, P.M., Numerical predictions of fl ow struc-ture above a dimpled surface in a channel. Numerical Heat Transfer-part A, 45, pp. 1–20, 2004.

    [24] Schabacker, J., Boelcs, A. & Johnson, B.V., PIV investigation of the fl ow characteristics in an internal coolant passage with two ducts connected by a sharp 180º bend. ASME Paper No. 98-GT-544, 1998.

    [25] Schabacker, J., Boelcs, A. & Johnson, B.V., PIV investigation of the fl ow characteristics in an internal coolant passage with 45deg rib arrangement. ASME Paper No. 99-GT-120, 1999.

    [26] Son, S.Y., Kihm, K.D. & Han, J.C., PIV fl ow measurements for heat transfer characterization in two-pass square channels with smooth and 90° ribbed walls. Int. J. Heat Mass Transfer, 45, pp. 4809–4822, 2002.

    [27] Rathjen, L., Hennecke, D.K., Bock, S. & Kleinstueck, R., Detailed heat/mass transfer distributions in a rotating two pass coolant channel with engine-near cross section and smooth walls. Heat Transfer in Gas Turbine Systems, ed. R. Goldstein, New York Academy of Sciences: New York, 2001, Ann. N.Y. Acad. Sci., 934, pp. 432–439, 2001.

    [28] Liou, T.M., Lee, H.L. & Liao, C.C., Effects of guide-vane number in a three-dimensional 60-deg curved side-dump combustor inlet. ASME J. Fluids Engineering, 123, pp. 211–218, 2001.

    [29] Liou, T.M., Lee, H.L. & Liao, C.C., Effects of inlet guide-vane number on fl owfi elds in a side-dump combustor. Experimental Thermal and Fluid Science, 24, pp. 11–23, 2001.

    [30] Ratna Rao, D.V., Babu, C.S. & Prabhu, S.V., Effect of turn region treatments on the pressure loss distribution in a smooth square channel with sharp 180° bend. Int J Rotating Machinery, 10(6), pp. 459–468, 2004.

    [31] Ratna Rao, D.V. & Prabhu, S.V., Effect of turn region treatments on the pressure loss through sharp 180 deg bends. AIAA 1st International Energy Conversion Engineering Conference, 17–21 August 2003, Portsmouth, Virginia. Paper no. AIAA 2003-5961.

    [32] Babu, C.S., Ratna Rao, D.V. & Prabhu, S.V., Effect of guide vanes on pres-sure drop in a rib roughened square channel with a sharp cornered 180° bend. AIAA 41st Aerospace Sciences Meeting and Exhibit, 6–9 January 2003, Reno, Nevada. Paper no. AIAA 2003-1145.

    www.witpress.com, ISSN 1755-8336 (on-line) WIT Transactions on State of the Art in Science and Engineering, Vol 63, © 2013 WIT Press

  • 88 EMERGING TOPICS IN HEAT TRANSFER

    [33] Luo, J. & Razinsky, E.H., Analysis of turbulent fl ow in 180 deg turning ducts with and without guide vanes. ASME J. Turbomachinery, 131, paper no. 021011, 2009.

    [34] Han, J.C., Chandra, P.R. & Lau, S.C., Local heat/mass transfer distributions around sharp 180-deg turns in two-pass smooth and rib- roughened channels. ASME J. Heat Transfer, 110, pp. 91–98, 1988.

    [35] Wagner, J.H., Johnson, B.V. & Kopper, F.C., Heat transfer in rotating serpen-tine passages with smooth walls. ASME J. Turbomachinery, 113, pp. 321–330, 1991.

    [36] Wagner, J.H., Johnson, B.V., Graziani, R.A. & Yeh, F.C., Heat transfer in rotating serpentine passages with trips normal to the fl ow. ASME J. Turboma-chinery, 114, pp. 847–857, 1992.

    [37] Bunker, R.S., The augmentation of internal blade tip-cap cooling by arrays of shaped pins. Proceedings of GT2007, ASME Turbo 2007: Power for Land, Sea, Air, May 14–17, Montreal, Canada. GT2007-27009. Also in ASME J. Turbomachinery, 130, paper no. 041007, 2008.

    [38] Xie, G.N., Sundén, B., Wang, L. & Utriainen, E., Enhanced heat transfer on the tip-wall in a rectangular two-pass channel by pin-fi n arrays. Numerical Heat Transfer-part A, 55, pp.739–761, 2009.

    [39] Xie, G.N., Sundén, B., Utriainen, E. & Wang, L., Computational analysis of pin-fi n arrays effects of internal heat transfer enhancement of a blade tip-wall. ASME J. Heat Transfer, 132, paper no. 031901, 2010.

    [40] Xie, G.N., Sundén, B. & Zhang, W.H., Comparisons of pins/dimples/protru-sions cooling concepts for an internal blade tip-wall at high Reynolds num-bers. International Heat Transfer Conference, IHTC-14, August 8–13, 2010, Washington D.C., USA. Paper no IHTC14-22284.

    [41] Xie, G.N. & Sundén, B., Comparison of heat transfer enhancement of an internal blade tip with metal or insulating pins. Advances in Applied Math-ematics and Mechanics, in press.

    [42] Xie, G.N., Sundén, B., Wang, L. & Utriainen, E., Augmented heat transfer of an internal blade tip by full or partial arrays of pin-fi ns. Heat Transfer Research, in press.

    [43] Xie, G.N. & Sundén, B., Conjugated analysis of heat transfer enhancement of an internal blade tip-wall with pin-fi n arrays. J. Enhanced Heat Transfer, in press.

    [44] Xie, G.N., Sundén, B. & Wang, Q.W., Predictions of enhanced heat trans-fer of an internal blade tip-wall with hemispherical dimples or protrusions. ASME J. Turbomachinery, in press.

    [45] Xie, G.N., Sundén, B., Wang, L. & Utriainen, E., Parametric study on heat transfer enhancement and pressure drop of an internal blade tip-wall with pin-fi n arrays. Heat Mass Transfer, 45, pp. 45–47, 2011.

    [46] Xie, G.N. & Sundén, B., Numerical predictions of augmented heat transfer of an internal blade tip-wall by hemispherical dimples. Int. J. Heat Mass Transfer, 53, pp. 5639–5650, 2010.

    [47] FLUENT version 6.3.26 Documentation.

    www.witpress.com, ISSN 1755-8336 (on-line) WIT Transactions on State of the Art in Science and Engineering, Vol 63, © 2013 WIT Press