MX SeriesMAGNETIC DRIVE PUMP
Instruction Manual
MAGNETIC DRIVE PUMP
CHEON-SEI FEEDER
CHEON-SEI
CHEON-SEI IND.CO.,LTD.PUMPLAND DIVISION
Thank you very much for purchasing CHEON-SEI MX magnetic drive pump.Before beginning operation, please read this instruction manual carefully. Wehope the pump will provide you with many years of trouble-free operation.
1. Cheon-Sei will warrant all products to be free of defects in material orworkmanship for a period of eighteen(18) months from date of shipment orone(1) year from the date of installation, whichever occurs first.
2. Any customer complaints will be reviewed by Cheon-Sei. Cheon-Sei willprovide such technical advice and assistance as necessary to resolve customercomplaints on a timely basis.
3. Cheon-Sei’s liability for any breach of this warranty shall be limited solely toreplacement or repair (at the sole option of Cheon-Sei of any part or parts foundto be defective during the warranty period, provided the product is properlyinstalled and is being used as originally intended.The customer must notify Cheon-Sei of any breach of this warranty within theabove mentioned warranty period.Defective parts must be shipped by customer or Agency to Cheon-Sei’s point ofmanufacture, transportation charges prepaid.
We will make every efforts to minimize losses and damage resulting from defect.However, please bear in mine that we cannot guarantee against damageresulting from problems with consumable parts, unsuitable or incorrect operation,or natural disaster, etc.
1) Are the products the same as you ordered?2) Are all accessories included?3) Is there any visible damage caused by vibration or shock during transport?4) Are any of the screws loose or missing?
We take great care to assure our products leave the factory in perfectcondition. However, in the event that this pump is found to be defecive,please report the details to CHEON-SEI or your local representative. We willdo our best to solve the problem as quickly as possible.
Introduction
Warranty
Checking points on unpacking
1. Notice for Safety 4
1-1 Introduction 4
1-2 Cautions for Use Condition 4
1-3 Cautions for Installation 4
1-4 Cautions for Operation 5
1-5 Cautions for Maintenance and Check 5
1-6 Cautions for Warranty and Repair Service 5
1-7 Others 5
2. Confirmation of Articles to be supplied 6
2-1 Check Point when Unpacking 6
2-2 Standard Accessories 6
3. General 6
3-1 Feature 6
3-2 Use 6
4. Model Code 7
5. Specifications 7
6. Materials of Liquid End 8
7. Performance Curves 8
8. Principle of Operation 9
9. Installation 9
9-1 Place of Installation 9
9-2 Piping 9
9-3 Dimension 10
9-4 Wiring 10
10. Operation 11
11. Maintenance 12
12. Cause of Trouble and Troubleshooting 12
13. Warranty 13
14. Repair Service 13
15. Structure and Name of Each Part 14
15-1 MX 30, 50, 85 14
15-2 MX 135 14
15-3 MX 250, 300 15
Contents
4
1 Notice for Safety
1-1 IntroductionTo use the products safely, the signs will be showed on the manual .Please keep the manual certainly for important matters of safety.The signs and indications are as followings.
Warning Person Death or serious injury will be occurred if warnings is not kept by wrong
handling.
Caution Person injury or property damage will be occurred if cautions is not kept by wrong
handling.
1-2 Cautions for Use Condition
Caution
The pump should not be used other purpose except for liquid injection, otherwise, accident ordamage may be occurred.The pump should never be used for kinds of liquids which caused liquid end parts to be damaged.Please keep as followings or may be caused trouble.
- Ambient temperature : 0~40℃- Temperature of handling liquid : 0~80℃- Viscosity of handling liquid : 1~30cp- Improper liquid to use :
Liquid included particles as like Fe, Ni etc. affecting magnet. Organic solvent liquid to expand PP material obviously and slurry liquid .
1-3 Cautions for Installation
Warning
Install the pump at place not touch by outsider or children except authorized person.Do not touch with wetted hand. Electric shock may be occurred.
Caution
Do not install the pump in place which ambient temperature is high (above 40℃) or lowsdown below freezing point, pump internal may be damaged.Do not install pump in place with heavy moisture and dust. Electric shock and trouble maybe caused.Install suction side of pump at lower place than liquid level of tank because of not self-suction.Check voltage constant and frequency of moter prior to wiring, and connet to specifiedpower.Electric shock may be occurred unless earthing to earth line, connect to earth line certainly.Entrust to electrical technician for wiring.Install specified magnetic switch and thermal relay to control and maintenance, etc. of pump.Do use standardized good for wiring and be carefully safety in accordance with technicalstandard and wiring regulations.Please check out if the motor is being rotated correctly by accurate wiring connection.If the motor is rotated backward, it can be a cause of pump damage.
5
1-4 Cautions for Operation
Warning
Do not operate the pump without pumping liquid, Internal parts is damaged.
Caution
In case of using a dangerous liquid, be sure to wear safety equipments like gloves, gogglesand mask, etc.Some water may be remained in pump head after final performance test. Remove the water in pump head and dry the pump necessarily, to avoid the problem thatmay be caused by abnormal phenomena of some liquid which may be occurred by areaction with water.Do not touch with bare hand on motor part when operation.A burn caused by high temperature may be occurred.Do not sudden open and close for valves of suction and discharge. Impellar can not be rotated due to confusion of magnetic polarities.
1-5 Cautions for Maintenance and Check
Warning
Electric shock may be caused when work, put off power stop pump and equipments.
Caution
Wear safety equipments certainly, because the remained liquid in pump internal may beflowed when disassembly or assembly.Do work after a release of the discharge piping pressure, and remove the remained liquid inthe pump head prior to repair or maintenance.Pump may be damaged when ambient temperature lows down below freezing point of liquidused. Do eliminate the liquid in pump and piping certainly after operation stop.
1-6 Cautions for Warranty and Repair Service
Warning
Cheon-Sei will not warrant if the pump is reconstructed arbitrarily or used by other partsexcept specified parts. And be cautious not to be compensated for a various expensehappened by a accident and trouble.
Caution
Prior to sending the pump for repair, wash the pump head’s internal clearly.Do not return the pump if the pump has been used with harmful and fatal liquid to health.
1-7 Others
Caution
Do proper protection certainly under considering discharge of liquid, when pump and pipingmay be damaged.Absolutely do not use the damged pump, because accident or trouble can be occurred.Dispose the disused pump in accordance with relation law.
2 Confirmation of Articles to be supplied
2-1 Check Point when UnpackingAre the products the same as you ordered?Are all accessories included?Is there any visible damage caused by vibration or shock during transport?Are any of the screws loose or missing?We take great care to assure our products leave the factory in perfect condition. However, inthe event that this pump is found to be defective, please report the details to CHEON-SEI oryour local representative. We will do our best to solve the problem as quickly as possible.
2-2 Standard AccessoriesInstruction manual ……………………………… 1 copyAnchor bolt(M1×115L) ………………………… 4 SET(For only MX-250, 300)
3-1 FeatureThere is no worry totally of liquid leakage to adopt indirect driving methode by ferrite magnetseperated pump room between motor.There is design of small and light caused by a high efficent motor and a compact pump chamber.Main parts like as pump chamber etc. are made with pp material, also shaft is used by high corrosionresistance material as like ceramic etc.All kinds of liquid are possible to transfer except some organic solvent. Cheon-sei Magnetic pump has excellent performance for transfer of chemical liquid as acid andalkali.
3-2 UseFilm auto developer, photo plate-making developer, photo liquid disposal.Supply of hot water in vending machine of soft drink and heating equipment, etc.Water tank with a constant temperature, gas analyzer, ion analyzer, chemical machinery, etc.Circulation of liquid in an ultrasonic washer and medical equipment, etc.Liquid disposal in equipment for removal of grease, acid cleaning, surface treatment equipment, etc.Cathode-ray tube production equipment, photo plate making equipment for IC, etc.Transfer, circulation and agitation of liquid medicine.Research room, laboratory, and test plant.
6
3 General
Note) 1. The figure of maximum capacity comes out at 0 head and that of maximum total head comes out with closing the discargevalve.
2. Viscosity limit of use liquid : 30cp (incase of specific gravity 1.0)3. The temperature of pumping liquid should be 0 to 80°C and use place is indoor.4. Do not pump the liquid to be frozen.5. The above specifications may be changed without prior notice according to its improvement.
7
5 Specifications
4 Model Code
- - -❶ ❷ ❸ ❹ ❺
SHP135MX
❶ Series Name
MX : MX(Magnetic Drive Pump) Series
❷ Model No. (Max. capacity)
135:135ℓ/min (60㎐)
❸ Liquid-end materials
P : PP X : Special
Connection type
H:Hose F:Flange T:Thread X:Special
Power supply
S:1ø 220V 60Hz A:3ø220/380V 60HzB:3ø 440V 60Hz X:Special
ModelSpecs.
MX-30
60㎐
MX-50
60㎐
MX-85
60㎐
Max.capacily(ℓ/min-m)
Max.head(m)
Standard Liquid capacity(ℓ/min-m)
30
4.3m
22-2
16mm
-
-
1.1
20W
2.9
2.1BG 6.1/6.1
50
2.8m
40-1.2
25mm
-
-
1phase
1.3
-
85
4.5m
65-2
25mm
-
-
65W
1.1
5.7
MX-135
25mm
KS 10K 25A
G 1
250W
1, 3 phase
1.8
8.8
6.3G 8.2/0.4
2.1BG 6.1/6.1
MX-250
-
KS 10K 40A
-
0.75kW
1.3
24.5
MX-300
-
KS 10K 40A
-
1.5kW
1.8
25.5
Connection
Type
Hose
Flange
Thread
MotorOutput
Phase
Max. Specific gravity
Weight
Painting
(Munsell No.)
1 Phase
3 Phase
50㎐
120
8.5
60-6
50㎐
225
10
120-7
50㎐
270
12.5
160-7.5
60㎐
135
12
70-9
60㎐
250
14
130-10
60㎐
300
17.5
170-11
3 phase
-
1.5BG 5.3/5
6 Materials of Liquid End
Note) The performance curves show examples at our testing facility under constant conditions. Purformance curves differat each local site.
8
7 Performance Curves
No.
①
②
③
④
⑤
⑥
Name of part
Casing
Impeller
Shaft
Bearing
Washer
O-ring
Material
PP
PP
CERAMIC
RULON
CERAMIC
FKM
1⃞ MX-30, 50 2⃞ MX-85
3⃞ MX-135 4⃞ MX-250, 300
Conditions : ----- 60Hz, - - - 50Hz, Room temperature, Clean water
9
9 Installation
8 Principle of Operation
As indicated in the figure, the impeller embedded the
magnet(impeller) is rotated by the magnet (driving)
attached to the motor shaft. It is called a magnet driven
pump. The pump chamber is mainly composed of a
polypropylene(PP) and isolated from the exterior. There
is no need of a pump shaft and mechanical seals
because of the rotation of the impeller by the magnets,
not by the motor.
Magnet(driving)
Magnet(Impeller)
Motor shaftSuction side
Impeller
Discharge side
driving housing
9-1 Place of Installation
Warning
Install the pump at place not to touch by outsider or children except authorized person.
Caution
Do not install the pump in place which ambient temperature is high (above 40℃) or lows downbelow freezing point, pump internal may be damaged.Do not install pump in place with heavy moisture and dust. Electric shock and trouble may becaused.Install suction side of pump at lower place than liquid level of tank because of not self-suction.
Install pump at easy place for maintenance and inspection. In case of pump installs at higher than level of tank, foot valve attaches on suction side and liquid shouldbe filled up in pump head prior to operation.
9-2 Piping
Caution
Use special heat-proof hose for transfer of liquid of high temperature.
Use corrosion resistance as like vinyl hose for piping of hose type and use flange of plasticseries for MX-135, 250, 300. Especially hose type uses wired hose(blade hose) to protectdistortion by suction pressure. Use hose band on connection part of hose for hose type and insert gasket and fully tighten
with bolts between flange not to leak liquid. Especially in case of connecion on suction sideis not safe, drop off capacity of pumping up.Shorten length and do not bend piping to reduce friction resistance of liquid.
9-3 Dimension
9-4 Wiring
Warning
Do not touch with wetted hand. Electric shock may be odcurred.
Caution
Check Voltage constant and frequency of motor prior to wiring, and connet to specificatedpower.Electric shock may be occurred unless earthing to earth line, connect to earth line certainly.Install specified magnetic switch and thermal relay to control and maintenance, etc. of pump.Do use standardized goods for wiring and be carefully safety in accordance with technicalstandard and wiring regulations.Please check out if the motor is being rotated correctly by accurate wiring connection.If the motor is rotated backward, it can be a cause of pump damage.
10
1⃞ MX-30, 50, 85 2⃞ MX-135(Hose, Thread type)
3⃞ MX-135(Flange type) 4⃞ MX-250, 300
Model
MX-30
MX-50
MX-85
W
109
109
120
H
112
122
144
L
225
235
305
A
48
48
60
B
64
64
80
C
93
93
102
D
50
50
65
E
40
47
50
F
125
135
163
Model
MX-135
W
140
H
170
L
340
A
90
B
110
C
112
D
68
E
65
F
184
Model
MX-250
MX-300
W
240
240
H
270
270
L
500
520
A
260
260
B
300
300
C
210
210
D
131
131
E
78
78
F
130
130
Model
MX-135
W
140
H
181
L
351
A
90
B
110
C
112
D
68
E
76
F
195
Rating current according to voltage of each type (60Hz standard)
Motor wiring method when 3phase 220/380V combination (Motor wired 220V when factoy shipping.)
Warning
Do not empty operation. Internal parts may be damaged.
Caution
In case of using a dangerous liquid, be sure to wear safety equipments like gloves, gogglesand mask, etc.Some water may be remained in pump head after final performance test.Remove the water in pump head and dry the pump necessarily, to avoid the problem thatmay be caused by abnormal phenomena of some liquid which may be occurred by areaction with water.Do not touch with bare hand on motor part when operation.A burn caused by high temperature may be occurred.Do not suddenly open and close for valves of suction and discharge. Impellar can not be rotated due to confusion of magnetic polarities.
Fill water up in pump room, close valve on discharge side, power on, and then open valve slowly. (Fill water up in suction hose and pump room and then power on in case of using foot valve.)
Check transfer of liquid without malfunction of pump. If not transfer immediately power off and removethe cause.Do not insert alien material in pump. If insert alien material, impellar may be locked. Motor rotateswithout transfer at case of lock, immediately power off and please remove alien material afterdisassemblying of pump.
220V 380V
11
10 Operation
Model
Voltage
220V
380V
440V
MX-30, 50
1 phase
0.4A
-
-
MX-85
1 phase
0.85A
-
-
MX-250
3 phase
3.2A
1.85A
1.6A
MX-300
3 phase
5.7A
3.3A
2.85A
MX-135
1 phase
2.1A
-
-
3 phase
1.7A
0.95A
0.9A
220V Wiring 380V Wiring
White
Black
Blue
Yellow
Green
Red
1
2
3
6
4 (△Wiring)
5
1
2
3
6
4 (Y Wiring)
5
White Blue Green
Black Yellow Red
11 Maintenance
12 Cause of Trouble and Troubleshooting
Warning
Electric shock may be caused when work, put off power stop pump and equipments.
Caution
Wear safety equipments certainly, because the remained liquid in pump internal may beflowed when disassembly or assembly.Do work after a release of the discharge piping pressure, and remove the remained liquid inthe pump head prior to repair or maintenance.Pump may be damaged when ambient temperature lows down below freezing point of liquidused. do eliminate the liquid in pump and piping certainly after operation stop.
Check operation status of pump, vibration, abnormal sound, and voltage value, dischargequantity.In case of something wrong, power off immediately and remove the causes with referenceof Article 'Causes of Trouble and Troubleshooting'.
12
Trouble Cause Remedy
Bad or disconnection of wire Check
Motor not work Bad of condenser (1 phase) Replace
Bad or disconnection of wire Repair and replace
Empty operation Check liquid before operation
Air in pump Get rid of air fully
Not pumping up orAir suction from suction side
Check and repair on connection of piping
capacity of pumping up to prevent air suction
is not much. Shrinking of suction hose(In case of hose type) Repace with wired hose not to shrink
Alien material attachment on impeller Clean impeller
Air in piping Get rid of air in piping
Excessive of specific gravity and viscosity for handling liquid Replace with proper pump
Overload of motorAlien material attachment on impeller Clean impeller
Outer circumference of impeller Replace parts
contacts on rear casing impeller damage Replace parts
Empty operationCheck circulation liquid on hose of suction
Noise and vibraion side or piping
are high. Alien material attachment on impeller Clean impeller
Impeller damage Replace parts
Leakage of liquidO-ring damage Replace parts
Rear casing damage Replace parts
Warning
Cheon-Sei will not warrant if the pump is reconstructed arbitarily or used by other parts exceptspecified parts. And be cautious not to be compensated for a various expense happened by aaccident and trouble.
Cheon-Sei will warrant all products to be free of defects in material or workmanship for a period ofeighteen(18) months from date of shipment or one(1) year from the date of installation, whicheveroccurs first.During guarantee period repair or change of pump is free of charge, if trouble or damage ofpump due to design or manufacturing of Cheon-Sei. ※ Consumable parts are excluded. Repair or change for pump having a trouble or damage caused by the following reasons shouldbe charged regardless of the guaranteed period.① Trouble or damage of pump expired guarantee period② Trouble of using by careless handling③ Trouble or damage due to using parts except of specified by Cheon-Sei.④ Trouble or damage due to repair or reconstruction by person except by Cheon-Sei or designated by
Cheon-Sei.⑤ Trouble by inevitability of fire or natural calamity
Caution
Prior to sending the pump for repairment, wash the pump head’s internal clearly.
Do not return the pump if the pump has been used with harmful and fatal liquids to health.
Contact to A/S Department of Cheon-Sei or Local Distributor as shown on back of the manual
when occurred abnormal of pump or has inquiry.
Inform following items when request repair of pump.
① Model Name and Production No. as shown on name plate of pump
② Used period and using condition, status, transfer liquid
Inquire to Local Distributor whether charge or not for repair when expired guarantee period of pump.
Minimum retain period of performance parts for repair of Cheon-Sei is 5 years from the date of production.
14 Repair Service
13 Warranty
13
15 Structure and Name of Each Part
15-1 MX-30, 50, 85
14
15-2 MX-135
Notice) (1) For only flange type
No. Part Name Q,ty
1 Front Casing 1
3 Rear Casing 1
7 Impeller Set 1
8 Bearing 2
No. Part Name Q,ty
11 Washer 2
16 O-ring 1
17 Bolt 6
18 Washer(Flat) 6
No. Part Name Q,ty
33 Driving Magnet Set 1
36 Moter 1
37 Set Screw 2
No. Part Name Q,ty
1 Front Casing 1
3 Rear Casing 1
4 Liner Ring 1
7 Impeller Set 1
8 Bearing “S” 1
9 Bearing “F” 1
No. Part Name Q,ty
10 Mouth Ring 1
11 Washer 1
13 Front Casing Cover 1
14(1) Flange 2
16 O-ring 1
17 Bolt(Hex.) 6
No. Part Name Q,ty
18 Washer(Flat) 6
20(1) Packing 2
33 Driving Magnet Set 1
36 Motor 1
37 Set Screw 2
15
15-3 MX-250, 300
No. Part Name Q,ty
2 Front Casing Set 1
3 Rear Casing 1
5 Impeller Set 1
8 Bearing 2
10 Mouth Ring 1
11 Washer 2
12 Shaft 1
14 Flange(Suction) 1
No. Part Name Q,ty
15 Flange(Discharge) 1
16 O-ring 1
17 Bolt(Hex.) 6
18 Washer(Flat) 6
19 Washer(Spring) 6
33 Driving Magnet Set 1
34 Braket 1
36 Motor 1
No. Part Name Q,ty
37 Set Screw 2
38 Bolt(Hex.) 6
39 Washer(Spring) 6
40 Bed 1
41 Bolt(Hex.) 4
42 Washer(Spring) 4
HEAD OFFICE:630-1, SUNGGOK-DONG, DANWON-GUANSAN-SHI, KYUNGKI-DO, KOREAPhone : +82+31+493-1003(REP.)F a x : +82+31+492-3683E-mail : [email protected] : http://www.cheonsei.co.kr
2003. 7. 15.CSME - G - 01
CHEON-SEI IND.CO.,LTD.PUMPLAND DIVISION