chp-3-strength analysis of beams according to aci code
DESCRIPTION
Chp-3-Strength Analysis of Beams According to ACI Code. - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Chp-3-Strength Analysis of Beams According to ACI Code](https://reader033.vdocument.in/reader033/viewer/2022061602/568162b1550346895dd33949/html5/thumbnails/1.jpg)
From the early 1900s until the early 1960s, nearly all reinforced concrete design in the United States was performed by the working-stress design method (also called allowable-stress design or straight-line design). [n this method, frequently referred to as WSD, the dead and live loads to be supported, called working loads or service loads, were first estimated. Then the members of the structure were proportioned so that stresses calculated by a transformed area did not exceed certain permissible or allowable values.
Chp-3-Strength Analysis of Beams According to ACI Code
![Page 2: Chp-3-Strength Analysis of Beams According to ACI Code](https://reader033.vdocument.in/reader033/viewer/2022061602/568162b1550346895dd33949/html5/thumbnails/2.jpg)
equivalent rectangular block
![Page 3: Chp-3-Strength Analysis of Beams According to ACI Code](https://reader033.vdocument.in/reader033/viewer/2022061602/568162b1550346895dd33949/html5/thumbnails/3.jpg)
![Page 4: Chp-3-Strength Analysis of Beams According to ACI Code](https://reader033.vdocument.in/reader033/viewer/2022061602/568162b1550346895dd33949/html5/thumbnails/4.jpg)
[ C = T ]
Mn , is defined as the theoretical or nominal resisting moment of a section. Mu is factored load, φ is strength reduction factor.
![Page 5: Chp-3-Strength Analysis of Beams According to ACI Code](https://reader033.vdocument.in/reader033/viewer/2022061602/568162b1550346895dd33949/html5/thumbnails/5.jpg)
The usable flexural strength[or ultimate moment capacity]
![Page 6: Chp-3-Strength Analysis of Beams According to ACI Code](https://reader033.vdocument.in/reader033/viewer/2022061602/568162b1550346895dd33949/html5/thumbnails/6.jpg)
p. 654for fy = 40,000 psi, and f’c = 4,000 psi
![Page 7: Chp-3-Strength Analysis of Beams According to ACI Code](https://reader033.vdocument.in/reader033/viewer/2022061602/568162b1550346895dd33949/html5/thumbnails/7.jpg)
![Page 8: Chp-3-Strength Analysis of Beams According to ACI Code](https://reader033.vdocument.in/reader033/viewer/2022061602/568162b1550346895dd33949/html5/thumbnails/8.jpg)
1. BALANCED SECTIONS, 2. TENSION-CONTROLLED SECTTONS and 3. COMPRESSTON-CONTROLLED OR BRITTLE SECTIONS
![Page 9: Chp-3-Strength Analysis of Beams According to ACI Code](https://reader033.vdocument.in/reader033/viewer/2022061602/568162b1550346895dd33949/html5/thumbnails/9.jpg)
Please continue to read page 71 be able to interpret Figure 3.5 for comprehension of :
![Page 10: Chp-3-Strength Analysis of Beams According to ACI Code](https://reader033.vdocument.in/reader033/viewer/2022061602/568162b1550346895dd33949/html5/thumbnails/10.jpg)
![Page 11: Chp-3-Strength Analysis of Beams According to ACI Code](https://reader033.vdocument.in/reader033/viewer/2022061602/568162b1550346895dd33949/html5/thumbnails/11.jpg)
failure can occur in very lightly reinforced beams. If the ultimate resisting moment of the section is less than its cracking moment, the section will fail immediately when a crack occurs. This type of failure may occur without warning. To prevent such a possibility, the ACI (10.5.1) specifies a certain minimum amount of reinforcing that must be used at every section of flexural members where tensile reinforcing is required by analysis, whether for positive or negative moments. In the following equations, bw, represents the web width of beams.
![Page 12: Chp-3-Strength Analysis of Beams According to ACI Code](https://reader033.vdocument.in/reader033/viewer/2022061602/568162b1550346895dd33949/html5/thumbnails/12.jpg)
![Page 13: Chp-3-Strength Analysis of Beams According to ACI Code](https://reader033.vdocument.in/reader033/viewer/2022061602/568162b1550346895dd33949/html5/thumbnails/13.jpg)
![Page 14: Chp-3-Strength Analysis of Beams According to ACI Code](https://reader033.vdocument.in/reader033/viewer/2022061602/568162b1550346895dd33949/html5/thumbnails/14.jpg)
![Page 15: Chp-3-Strength Analysis of Beams According to ACI Code](https://reader033.vdocument.in/reader033/viewer/2022061602/568162b1550346895dd33949/html5/thumbnails/15.jpg)
![Page 16: Chp-3-Strength Analysis of Beams According to ACI Code](https://reader033.vdocument.in/reader033/viewer/2022061602/568162b1550346895dd33949/html5/thumbnails/16.jpg)