CHR 290 / CHR 290 FC
Refrigeratori di liquidocon refrigerante ecologico R290ERP 2015-2017Installazione all’esternoCondensatori ad aria anche con Free CoolingCompressori Semiermetici
Progettati per ambienti commerciali,industriali e di processo
Liquid chillers with eco-friendly refrigerant R290
ERP 2015-2017Outdoor Installation
Air condensers also with Free Cooling
Semi-hermetic compressors
Designed for commercial, industrialand process environment
TECH LINE
2
INDICE - INDEX
Introduzione / Introduction .......................................................................................................................................p. 4
CHR 290 65,7-341 kW – STANDARD VERSION .................................................................................................... p. 7
Refrigeratori di liquido condensati con refrigerante ecologico R290
Air cooled liquid chiller with eco-friendly refrigerant R290
CHR 290 66,9-269,9 kW – CLASSE A \ A CLASS ............................................................................................. p. 23
Refrigeratori di liquido condensati con refrigerante ecologico R290
Air cooled liquid chiller with eco-friendly refrigerant R290
CHR 290 FC 71,9-373,3 kW – STANDARD VERSION ...................................................................................... p. 41
Refrigeratori di liquido condensati con refrigerante ecologico R290 – Free Cooling
Air cooled liquid chiller with eco-friendly refrigerant R290 – Free Cooling
CHR 290 FC 73,3-295,4 kW CLASSE A \ A CLASS ......................................................................................... p. 57
Refrigeratori di liquido condensati con refrigerante ecologico R290 – Free Cooling
Air cooled liquid chiller with eco-friendly refrigerant R290 – Free Cooling
CHR 290 / R290
Compressori semi ermetici / Semi–hermetic compressors
CHR 290 mod. 28 65,7-341 kW
CHR 290 FC mod. 28 71,9-373,3 kW
Refrigeratori di liquido condensati ad aria anche con Free Cooling
Air cooled liquid chiller also with Free Cooling
3
AIR CONDITIONING CH R 290 / CH R 290 FCTECH LINE
EXCELLENT PERFORMANCE
Di primaria qualità internazionale
Primary international quality
Costruzione ConstructionLe carpenterie sono robuste e resistenti, costruite in lamiera di acciaio al carbonio zincata
Frame are built in galvanized metal sheet. They are robust and resistant
Verniciatura Coating - RAL 7035A forno con polveri epossidiche per assicurare una miglior resistenza agli agenti atmosferici
Oven epoxy paint to ensure a better resistance to weathering
Rumorosità e vibrazioni Noise and vibrationLimitate grazie ad un design attento e innovativo
Limited thanks to a careful and innovative design
Installazione InstallationCarenatura idonea per l’installazione all’esterno e alle intemperie. Tutte le connessioni
sono state studiate per facilitare al massimo le operazioni di installazione
Weatherproof housing suitable for outdoor installation
All connections are designed to maximize ease of installation operations
Ergonomia e accessibilità Ergonomics and accessibilityFacile accesso ai principali componenti anche con unità in funzionamento
Easy access to main components even when the unit is running
Funzionamento OperationComando e controllo dell’unità con microprocessore di ultima generazione
Command and control unit with a microprocessor controller of latest generation
Componenti Standard Standard Components
4
Configurazione Configuration Prodotto configurabile con una vasta gamma di accessori
Configurable product with a wide range of accessories
Manutenzione MaintenanceCosti limitati in funzione della qualità e reperibilità dei componenti e del facile accesso
Limited costs in function of quality, availability and easy access of the components
Controllo a distanza Remote ControlPannello remoto e scheda seriale (dove previsto) per controllo remoto dell’unità
Remote control panel and serial card (where provided) for remote control of the unit
Norme Europee European StandardsSecondo direttive e normative CE
According to EC directives and regulations
Direttiva Macchine 2006/42/CE: 2006
Machinery Directive 2006/42/EC: 2006
Direttiva compatibilità Elettromagnetica 2004/108/CE: 2004
EMC Directive 2004/108/EC: 2004
PED Direttiva attrezzature a pressione 97/23/CE
PED Pressure Equipment Directive 97/23/EC
Direttiva Bassa Tensione 2006/95/CE: 2006
LVD Directive 2006/95/EC: 2006
5
AIR CONDITIONINGTECH LINE CH R 290 VDS 65,7 - 341 kW
6
COMMERCIAL LINETECH LINE
CHR 290 65,7-341 kW
7
AIR CONDITIONINGTECH LINE
CH R 290CH R 290La più ampia gamma di refrigeratori di liquido (EN14511:2013 e classe
energetica ERP 2015-2017) condensati ad aria per installazione in
esterno per ambienti commerciali, industriali e di processo
A wide range of air cooled liquid chillers (EN14511:2013 and energy
regulation ERP 2015-2017), air condensed for outdoor installation for
commercial, industrial and process enviroments
Bicold Engineering Srl da sempre realizza prodotti nel rispetto dell’ambiente
e del risparmio energetico in sintonia con direttive e normative comunitarie
e ponendo la sua attenzione sui problemi legati all’impatto ambientale
con l’obiettivo di essere in coerenza con quanto stabilito dal protocollo di
Montreal (1987), dal protocollo di Kyoto (1997) e il più recente regolamento
(UE) n.517/2014 del Parlamento e del consiglio Europeo, del 16 aprile
2014, sui gas fluorurati a effetto serra e che abroga il regolamento (CE) n.
842/2006.
La ricerca di nuovi refrigeranti a basso impatto ambientale, la limitazione
all’utilizzo e la tassazione per ragioni ambientali su alcuni refrigeranti
sintetici nei prossimi anni, hanno fatto guadagnare al propano (R290) una
alternativa naturale ai tradizionali gas refrigeranti (CFC-HCFC-HFC), ad alto
coefficiente di GWP (Global Warning Potential)
Il propano (R290), come gas refrigerante, non è penalizzato da restrizioni
o regolamenti che ne limitino l’uso, in questo modo può essere utilizzato
per qualsiasi applicazione nel settore del condizionamento, dei processi
industriali e della refrigerazione (applicazioni in media temperatura).
La progettazione è stata realizzata considerando gli elevati contenuti tecnici
in relazione all’utilizzo del propano R290 e le esigenze del mercato a cui
questo prodotto si riferisce. Il principio di base è la combinazione dell’R290
come refrigerante ecologico e il rispetto dei livelli di efficienza ed affidabilità
più elevati.
Applicazioni
• Refrigerazione (in media temperatura)
• Condizionamento
• Processo industriale
Impianti
• Refrigerazione commerciale (negozi, minimarket e supermarket)
• Refrigerazione industriale (centri logistici del freddo e industria
alimentare)
• Catering (Ristorazione)
• Condizionamento comfort
• Processo industriale
• Applicazioni speciali
Installazione
Le unità sono fornite per il funzionamento all’esterno, vengono equipaggiate
con una robusta carpenteria verniciata con vernice epossidica RAL7035
particolarmente resistente agli agenti atmosferici, che ne consente l’impiego
anche in condizioni ambientali estreme.
65,7 – 341 kW
H
Hgrandi collettività
large community
sanità
health
residenziale
residential
commerciale
commercial
terziario
tertiary
industriale
industrial
CH R 290 VDS 65,7 - 341 kW
8
the use of propane R290 and market demands in the relevant sector. The
basic principle lies in the use of the eco-friendly refrigerant R290 combined
with meeting the highest standards in terms of efficiency and reliability.
Applications
• Refrigeration (medium temperature application)
• Air conditioning
• Cooling process
Systems
• Commercial refrigeration (sales outlets, minimarkets and supermarkets)
• Industrial refrigeration (logistic cooling centres and food industry)
• Catering
• Air conditioning comfort
• Process cooling
• Special applications
Installation
The units are supplied for operation outdoors. In the case of outdoor
installation, they are equipped with a rugged framework finished with epoxy
paint RAL7035, particularly resistant to atmospheric agents to enable use
even in extreme environmental conditions.
Bicold Engineering Srl has always manufactured energy efficient and eco-
friendly products, in observance of the European directives and standards,
and paying special attention to issues linked to environmental impact with
the objective of meeting all requirements as specified by the protocol of
Montreal (1987) and the protocol of Kyoto (1997) in terms of environmental
emissions, as well as the most recent regulation (EU) no.517/2014 of
the European Parliament and Council, of 16 April 2014, on fluorinated
greenhouse gases, repealing regulation (EC) no. 842/2006.
The research into new refrigerants with low environmental impact, the
limitation of use and taxation for environmental reasons on a number of
synthetic refrigerants over the next few years have meant that propane
(R290) is a natural alternative to traditional refrigerants (CFC-HCFC-HFC),
with high GWP coefficient (Global Warning Potential)
Propane (R290) has attracted a great deal of interest with respect to
synthetic refrigerants (CFC-HCFC-HFC).
R290 is not subject to constraints or regulations that limit use, and therefore
can be used in Air conditioning, cooling process and refrigeration (medium
temperature application).
The design stage took into account the high technical content in relation to
9
AIR CONDITIONINGTECH LINE
CH R 290 PLUS
(in quanto questo tipo di gas è già presente in natura)
(as this gas is already present in nature)
Refrigerante al 100% rispettoso verso l’ambiente
Refrigerant 100% environmentally friendly
Refrigerante non tossico
Non toxic refrigerantRefrigerante naturale
Natural refrigerant
Refrigerante di facile e globale disponibilità
Globally and easily available refrigerant
Refrigerante con la massima sicurezza ambientaleRefrigerant with guaranteed maximum environmental safety
Refrigerante a basso costo
Low cost refrigerant
Potenziale di distruzione dell’ozono ODP (ozone depleting potential) pari a zero (assenza di CFC all’interno del refrigerante)
Ozone depletion potential (ODP) equal to zero(no CFCs in the refrigerant)
Tasso di riscaldamento globale del pianeta GWP (global warming potential) pari a 3
Global warming potential (GWP) equal to 3
Classe A in funzionamento Raffreddamento (opzionale)
A Class in cooling version (optional)
Basso contenuto di refrigerante
Lower refrigerant charge
Controllo auto adattativo che permette:
1. Limitazione spunti avviamento compressore
2. Tempo minimo di funzionamento del
compressore per il ritorno dell’olio
3. Possibilità di ridurre o eliminare l’uso di un
serbatoio dell’acqua
Adaptive self-control that allows:
1. Limitation compressor starter
2. Minimum run time of the compressor for
oil return
3. Possibility to reduce or eliminate the use
of a water tank
CH R 290 VDS 65,7 - 341 kW
10
Nuovo ventilatore ad alta efficienza con pale in tecno polimero per una ridotta emissione sonora
New high efficiency axial fans with blades in high resistance tecnopolymer, with low sound emission
Disponibile con recupero energetico parziale
integrato che consente di recuperare il
calore di condensazione che può consentire
la produzione gratuita di acqua calda a
temperatura massima 50°C per vari utilizzi:
1. Acqua calda sanitaria
2. Batterie ad acqua calda per post-
riscaldamento (centrali trattamento aria e
roof top ecc.)
3. Altri processi o lavorazioni che richiedono
acqua calda
Available with partial integrated energy recovery that allows to recover the heat of condensation in order to produce free hot water at maximum 50°C to use it for:
1. Domestic hot water2. Hot water Batteries post - heating
(air handling units and roof top units etc.)
3. Other processes or processes that require hot water
Estesi limiti di funzionamento
• Temperatura esterna 0°C / +43°C
• Produzione acqua calda +40°C / +45°C
Extended operating limits• Ambient temperature 0°C / +43°C• Hot water production +40°C / +45°C
A richiesta carpenteria
in acciaio INOX
Stainless steel version on demand
Free Cooling è il raffreddamento gratuito di un fluido grazie alla bassa temperatura
dell’ambiente esterno, senza l’attivazione di compressori con un risparmio energetico.
Free Cooling a liquid thanks to low ambient temperature that avoids to switch on the compressors and saves energy
Carpenteria saldata
Welded frame
Applicazioni a bassa temperatura acqua in funzionamento
raffrescamento fino a -5°C
Low water temperature applications in cooling operation down to -5°C
Tubazioni in acciaio inossidabile
Stailess steel piping
Separazione aeraulica tra il circuito refrigerante e il lato condensazione
Aeraulic separation between the refrigerant circuit and the condensation side
Modulazione della capacità dell’impianto ottimizzando il consumo energetico
Modulation system capacity optimizing the energy consumption
11
AIR CONDITIONINGTECH LINE
Identificazione del modello - Identificazione del modello
R290CH 2 230 VDS MH
CH MODELLI MODELS
Gruppi refrigeratori di liquido con condensazione ad ARIA con ventilatori assiali (installazione idonea all’esterno), con
compressori semi ermetici ed evaporatori a piastre
Liquid chillers AIR cooled with axial fans (for outdoor installation), with semi hermetic compressors and plates exchanger
REFRIGERANTE REFRIGERANT
Propano R290
Propane R290
ALLESTIMENTO CONFIGURATION
HE Unità ad alta efficienza con compressori più piccoli e batterie maggiorate
PHR Unità con recuperatore di calore parziale
IXF Unità con carpenteria in acciaio inox
IXWP Unità con tubazioni acqua in acciaio inox
SPBT Unità con serbatoio in acciaio inox
SDF Unità con carpenteria saldata
SE Unità con solo evaporatore. E’ compreso il pressostato differenziale a protezione dell’evaporatore.
MP Unità con evaporatore e una pompa centrifuga. E’ compreso il pressostato differenziale a protezione dell’evaporatore.
DP Unità con evaporatore e doppia pompa centrifuga. E’ compreso il pressostato differenziale a protezione dell’evaporatore.
MH Unità con modulo idronico; l’allestimento comprende una pompa centrifuga, il serbatoio di accumulo, la valvola di sicurezza acqua tarata a 3 Bar e il pressostato differenziale a protezione dell’evaporatore.
MHD Unità con modulo idronico; l’allestimento comprende la doppia pompa centrifuga, il serbatoio di accumulo, la valvola di sicurezza acqua tarata a 3 Bar e il pressostato differenziale a protezione dell’evaporatore.
HE High efficiency unit with a combination of smaller compressors and bigger condenser
PHR Unit with partial heat recovery (desuperheater)
IXF Unit with inox frame
IXWP Unit with water stainless steel pipes
SPBT Unit with buffer tank
SDF Unit with welded frame
SE Unit with evaporator only. It includes differential pressure switch for evaporator protection
MP Unit with evaporator and one centrifugal pump. It includes differential pressure switch for evaporator protection.
DP Unit with evaporator and double centrifugal pump. It includes differential pressure switch for evaporator protection.
MH Unit with hydronic modul; configuration includes one centrifugal pump, buffer tank, safety water valve (set 3 Bar) and differential pressure switch for evaporator protection.
MHD Unit with hydronic modul; configuration includes double centrifugal pump, buffer tank, safety water valve (set 3 Bar) and differential pressure switch for evaporator protection.
N. CIRCUITI FRIGORIFERI N. REFRIGERANT CIRCUIT
2 due circuiti
2 two circuits
VERSIONE VERSION
VDS di serie - A Classe A
VDS standard - A A class
R290
2
VDS
MH
TAGLIA SIZE
Potenza frigorifera [kW] alle condizioni operative nominali (temperatura acqua refrigerata +12/+7 °C temperatura aria esterna +32 °C)
Cooling capacity [kW] at nominal operating conditions (chilled water temperature +12/+7 °C outdoor air temperature +32 °C)
230
CH R 290 VDS 65,7 - 341 kW
12
Garanzia di Qualità e Risparmio Energetico
Quality and Energy Saving Guarantee
13
AIR CONDITIONINGTECH LINE
I modelli denominati CH R290 sono unità solo freddo.
Il fluido frigorigeno utilizzato è l’R290.
L’intera gamma è sostituita da un ampio numero di modelli con
potenza frigorifera da 65,7 a 341 kW ed è caratterizzata da soluzioni
attente all’efficienza energetica, alla silenziosità, versatilità e alla
semplicità nell’uso e la manutenzione.
I compressori utilizzati sono del tipo semi ermetico a pistoni progettati
per il funzionamento con il refrigerante R290.
I condensatori sono del tipo a batteria con tubo in rame e alette in
alluminio ad alta efficienza.
I ventilatori impiegati sono del tipo assiale a basso numero di giri
e alta efficienza realizzati in polimero ad alta resistenza, di serie è
presente un controllo di velocità dei ventilatori attraverso un regolatore
di giri a taglio di fase (opzionale elettronico).
Lo scambiatore rigenerativo è a piastre saldobrasate in acciaio
inox AISI 316 ed è termicamente isolato con materiale espanso a
cellule chiuse per una maggior protezione del compressore e per
aumentare le performance del sistema.
L’evaporatore è a piastre saldobrasate in acciaio inox AISI 316 ed è
termicamente isolato con materiale espanso a cellule chiuse.
Il circuito frigorifero include la valvola di espansione con funzione
MOP, filtro deidratatore, indicatore di passaggio e umidità, pressostati
di alta e bassa pressione e valvola di sicurezza.
La regolazione dei refrigeratori avviene mediante un controllore
elettronico a microprocessore.
Per tutti i modelli della gamma CH R290 è attiva la funzione di
“unloading per alta pressione”, che permette il funzionamento
dell’unità anche in condizioni ambientali estreme.
Le carpenterie sono costruite in lamiera di acciaio al carbonio zincata
e con verniciatura a forno con polveri epossidiche per assicurare la
migliore resistenza agli agenti atmosferici.
Il colore delle unità è il RAL 7035.
Alcuni componenti possono essere certificati Atex.
CARATTERISTICHE PRINCIPALI
CH R 290 VDS 65,7 - 341 kW
14
Models CH R290 are only cooling units.
These units work with refrigerant R290.
The whole range is composed of several models with cooling capacity
from 65,7 kW up to 341 kW and it is defined by solutions careful
to energy efficiency, soundproof, versatility and easiness of use and
maintenance.
Semi hermetic compressors designed to work with refrigerant R290.
High efficiency condenser coils are made of copper pipes and
aluminium fins.
High efficiency fans are axial type with low RPM made in high
resistance tecnopymer, there is as a standard equipment a fan speed
regulator by a speed cut phase regulator (electronic as option).
The regenerative heat exchanger is stainless steel AISI 316 brazed
plates with thermal insulation of close cells material for compressors
higher protection and to increase the performance of the system.
The evaporator is stainless steel AISI 316 brazed plates with thermal
insulation of close cells material.
Refrigerant circuit includes expansion valve with MOP function, drier
filter, sight glass, high and low pressure switches and safety valve.
Units are regulated by a microprocessor electronic board.
In all models of CH R290 there is the “high pressure unloading”
function which guarantees the operation of the units even in heavy
weather conditions.
Frames are built in galvanized metal sheet and oven painting with
epoxy powder to ensure resistance to atmospheric agents.
Color is RAL 7035.
Some components can be certified Atex.
MAIN FEATURES
15
AIR CONDITIONINGTECH LINE
1) Temperatura aria esterna 32°C; temperatura acqua ingresso-uscita evaporatore 12-7°C / In/out evaporator water 12/7 °C outside air temperature 32 °C 2) Temperatura aria esterna 25°C; temperatura acqua ingresso-uscita evaporatore 15-10°C / In/out evaporator water 15/10 °C outside air temperature 25 °C 3) FLA = Corrente assorbita a pieno carico. Nella versione Std senza pompa. / Absorbed current at full charge. Standard version without pump. 4) FLI = Potenza assorbita a pieno carico. Nella versione Std senza pompa. / Absorbed power at full charge. Standard version without pump. 5) ICF = Corrente di spunto alla partenza dell’ultimo compressore. Nella versione std senza pompa/ Max starting current (when last compressor starts) Standard version without pump 6) Valore della pressione sonora Lp(A) senza gruppo idronico, a 10 metri dalla macchina, 1 metro di altezza da terra ed in campo libero.
Noise pressure value Lp(A) without hydronic group, at 10 mt, at 1 high mt from the ground, in free field conditions 7) Connessioni ODS con attacco femmina a saldare / Welded female connections ODS
MOD. CH R290 1065 1070 2100 2120 2130 2135 2150 2160
PRESTAZIONI / PERFOMANCES (W 12/7°- A 32°)
Potenza frigorifera / Cooling capacity (1) kW 65,7 70,3 104,0 120,4 131,3 138,7 151,6 164,0
Potenza assorbita compressori / Compressors absorbed power (1) kW 17,6 19,3 24,0 30,8 35,2 38,9 43,5 49,5
EER (1) - 3,40 3,35 3,80 3,52 3,40 3,28 3,23 3,10
Potenza frigorifera / Cooling capacity (EN14511:2013) kW 65,3 69,9 103,5 119,8 130,7 138,0 150,9 163,2
Potenza assorbita totale / Total absorbed power (EN14511:2013) kW 19,7 21,4 27,9 34,8 39,2 43,0 47,6 53,7
EER (EN14511:2013) - 3,32 3,27 3,71 3,44 3,33 3,21 3,17 3,04
EVAPORATORE / EVAPORATOR
Tipo / Type - Piastre / Plates
N.ro / No. - 1 1 1 1 1 1 1 1
Portata acqua / Water flow (1) m3/h 11,30 12,09 17,89 20,71 22,58 23,86 26,08 28,21
Perdita di carico / Pressure drop (1) kPa 43 42 41 43 45 44 42 46
Prevalenza utile (Allestimento MP) / Available pressure (MP configuration) (1) kPa 200 195 191 182 218 215 209 198
PRESTAZIONI / PERFORMANCES (W 20/15°- A 25°)
Potenza frigorifera / Cooling capacity (2) kW 85,7 91,7 135,7 157,0 171,3 180,9 197,8 213,9
Potenza assorbita compressori / Compressors absorbed power (2) kW 18,1 19,8 24,7 31,6 36,1 39,9 44,6 50,8
EER (2) - 4,33 4,27 4,83 4,49 4,34 4,18 4,12 3,95
Potenza frigorifera / Cooling capacity (EN14511:2013) kW 85,0 91,0 134,8 156,0 170,2 179,7 196,6 212,5
Potenza assorbita totale / Total absorbed power (EN14511:2013) kW 20,5 22,2 29,0 36,0 40,6 44,5 49,2 55,6
EER (EN14511:2013) - 4,15 4,10 4,65 4,33 4,19 4,04 4,00 3,82
EVAPORATORE / EVAPORATOR
Tipo / Type - Piastre / Plates
N.ro / No. - 1 1 1 1 1 1 1 1
Portata acqua / Water flow (1) m3/h 14,74 15,77 23,34 27,00 29,46 31,12 34,02 36,79
Perdita di carico / Pressure drop (1) kPa 73 71 70 73 77 75 72 78
Prevalenza utile (Allestimento MP) / Available pressure (MP configuration) (1) kPa 142 135 147 131 162 158 150 132
COMPRESSORI / COMPRESSORS
Tipo / type Semi ermetico / Semi hermetic
N.ro / No. - 1 1 2 2 2 2 2 2
N.ro compressori / No. compressors
N.ro di circuiti frigoriferi / No. refrigerant circuits-/- 1 / 1 1 / 1 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2
Gradini di parzializzazione / Capacity steps - 2 2 4 4 4 4 4 4
CONDENSATORE / CONDENSER
Tipo / Type Batteria alettata / Finned coil
N.ro / No. - 1 1 1 1 1 1 1 1
VENTILATORI / FANS
Tipo / Type - Assiali / Axials
N.ro/Diametro / No./Diameter - 1x800 1x800 2x800 2x800 2x800 2x800 2x800 2x800
Portata aria totale / Total air flow m3/h 21.000 21.000 42.000 42.000 42.000 42.000 42.000 42.000
CH R 290 VDS 65,7 - 341 kW
16
1) Temperatura aria esterna 32°C; temperatura acqua ingresso-uscita evaporatore 12-7°C / In/out evaporator water 12/7 °C outside air temperature 32 °C 2) Temperatura aria esterna 25°C; temperatura acqua ingresso-uscita evaporatore 15-10°C / In/out evaporator water 15/10 °C outside air temperature 25 °C 3) FLA = Corrente assorbita a pieno carico. Nella versione Std senza pompa. / Absorbed current at full charge. Standard version without pump. 4) FLI = Potenza assorbita a pieno carico. Nella versione Std senza pompa. / Absorbed power at full charge. Standard version without pump. 5) ICF = Corrente di spunto alla partenza dell’ultimo compressore. Nella versione std senza pompa/ Max starting current (when last compressor starts) Standard version without pump 6) Valore della pressione sonora Lp(A) senza gruppo idronico, a 10 metri dalla macchina, 1 metro di altezza da terra ed in campo libero.
Noise pressure value Lp(A) without hydronic group, at 10 mt, at 1 high mt from the ground, in free field conditions 7) Connessioni ODS con attacco femmina a saldare / Welded female connections ODS
MOD. CH R290 1065 1070 2100 2120 2130 2135 2150 2160
DATI ELETTRICI / ELECTRICAL DATA
FLA (3) A 59,6 63,6 97,2 103,2 119,2 127,2 127,2 139,2
FLI (4) kW 22,4 24,2 32,8 40,4 44,8 48,4 53,3 59,3
ICF (5) A 248,6 263,6 255,2 258,2 308,2 327,2 327,2 333,2
MODULO IDRONICO(opzionale) - HYDRONIC KIT(option)
N.ro di pompe standard / No. of standard pumps - 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2
Potenza nominale pompa / Pump nominal power kW 1,50 1,50 2,20 2,20 3,00 3,00 3,00 3,00
Capacità serbatoio / Tank volume dm3 - - 300 300 300 300 300 300
Prevalenza utile (Allestimento MH) / Available pressure (MH configuration) (1) kPa 185 180 176 167 203 200 194 183
Livello sonoro Lp(A) / Sound level Lp(A) (6) dB(A) 58 58 61 61 61 61 61 61
Diametro connessioni idrauliche / Hydraulic connections diameter (in/out) inch 2" 2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 3"
DIMENSIONI E PESI / DIMENSIONS AND WEIGHTS
Lunghezza / Lenght mm 1.800 1.800 2.900 2.900 2.900 2.900 2.900 2.900
Larghezza / Depth mm 1.200 1.200 1.200 1.200 1.200 1.200 1.200 1.200
Altezza / Height mm 2.400 2.400 2.400 2.400 2.400 2.400 2.400 2.400
Peso (senza modulo idronico) / Weight (without hydronic kit) kg 598 620 807 825 852 876 890 908
17
AIR CONDITIONINGTECH LINE
1) Temperatura aria esterna 32°C; temperatura acqua ingresso-uscita evaporatore 12-7°C / In/out evaporator water 12/7 °C outside air temperature 32 °C 2) Temperatura aria esterna 25°C; temperatura acqua ingresso-uscita evaporatore 15-10°C / In/out evaporator water 15/10 °C outside air temperature 25 °C 3) FLA = Corrente assorbita a pieno carico. Nella versione Std senza pompa. / Absorbed current at full charge. Standard version without pump. 4) FLI = Potenza assorbita a pieno carico. Nella versione Std senza pompa. / Absorbed power at full charge. Standard version without pump. 5) ICF = Corrente di spunto alla partenza dell’ultimo compressore. Nella versione std senza pompa/ Max starting current (when last compressor starts) Standard version without pump 6) Valore della pressione sonora Lp(A) senza gruppo idronico, a 10 metri dalla macchina, 1 metro di altezza da terra ed in campo libero.
Noise pressure value Lp(A) without hydronic group, at 10 mt, at 1 high mt from the ground, in free field conditions 7) Connessioni ODS con attacco femmina a saldare / Welded female connections ODS
MOD. CH R290 2190 2200 2220 2230 2270 2290 2310 2330
PRESTAZIONI / PERFOMANCES (W 12/7°- A 32°)
Potenza frigorifera / Cooling capacity (1) kW 194,3 208,0 227,7 237,8 274,1 298,0 321,0 341,0
Potenza assorbita compressori / Compressors absorbed power (1) kW 53,9 58,9 65,9 71,0 78,5 87,2 95,9 104,1
EER (1) - 3,29 3,25 3,21 3,12 3,21 3,17 3,13 3,07
Potenza frigorifera / Cooling capacity (EN14511:2013) kW 193,5 207,1 226,7 236,8 273,0 296,8 319,7 339,7
Potenza assorbita totale / Total absorbed power (EN14511:2013) kW 59,8 64,9 72,0 77,1 86,4 95,2 104,0 112,2
EER (EN14511:2013) - 3,23 3,19 3,15 3,07 3,16 3,12 3,08 3,03
EVAPORATORE / EVAPORATOR
Tipo / Type - Piastre / Plates
N.ro / No. - 1 1 1 1 1 1 1 1
Portata acqua / Water flow (1) m3/h 33,42 35,78 39,16 40,90 47,15 51,26 55,21 58,65
Perdita di carico / Pressure drop (1) kPa 45 44 47 45 44 45 46 47
Prevalenza utile (Allestimento MP) / Available pressure (MP configuration) (1) kPa 204 201 193 192 237 226 213 202
PRESTAZIONI / PERFORMANCES (W 20/15°- A 25°)
Potenza frigorifera / Cooling capacity (2) kW 253,5 271,3 297,1 310,2 357,8 388,8 418,8 448,8
Potenza assorbita compressori / Compressors absorbed power (2) kW 55,3 60,5 67,5 72,8 80,5 89,4 98,3 106,7
EER (2) - 4,20 4,14 4,09 3,98 4,10 4,04 3,98 3,92
Potenza frigorifera / Cooling capacity (EN14511:2013) kW 251,9 269,7 295,2 308,3 355,7 386,5 416,3 442,2
Potenza assorbita totale / Total absorbed power (EN14511:2013) kW 62,0 67,2 74,5 79,8 89,4 98,5 107,6 116,1
EER (EN14511:2013) - 4,06 4,01 3,96 3,87 3,98 3,93 3,87 3,81
EVAPORATORE / EVAPORATOR
Tipo / Type - Piastre / Plates
N.ro / No. - 1 1 1 1 1 1 1 1
Portata acqua / Water flow (1) m3/h 43,60 46,66 51,10 53,35 61,54 66,87 72,03 76,51
Perdita di carico / Pressure drop (1) kPa 77 75 80 77 75 77 78 80
Prevalenza utile (Allestimento MP) / Available pressure (MP configuration) (1) kPa 155 150 134 132 164 144 123 104
COMPRESSORI / COMPRESSORS
Tipo / type Semi ermetico / Semi hermetic
N.ro / No. - 2 2 2 2 2 2 2 2
N.ro compressori / No. compressors
N.ro di circuiti frigoriferi / No. refrigerant circuits-/- 2 / 2 2 / 2 2/2 2/2 2/2 2/2 2/2 2/2
Gradini di parzializzazione / Capacity steps - 4 4 4 4 4 4 4 4
CONDENSATORE / CONDENSER
Tipo / Type Batteria alettata / Finned coil
N.ro / No. - 1 1 1 1 1 1 1 1
VENTILATORI / FANS
Tipo / Type - Assiali / Axials
N.ro/Diametro / No./Diameter - 3x800 3x800 3x800 3x800 4x800 4x800 4x800 4x800
Portata aria totale / Total air flow m3/h 63.000 63.000 63.000 63.000 84.000 84.000 84.000 84.000
CH R 290 VDS 65,7 - 341 kW
18
1) Temperatura aria esterna 32°C; temperatura acqua ingresso-uscita evaporatore 12-7°C / In/out evaporator water 12/7 °C outside air temperature 32 °C 2) Temperatura aria esterna 25°C; temperatura acqua ingresso-uscita evaporatore 15-10°C / In/out evaporator water 15/10 °C outside air temperature 25 °C 3) FLA = Corrente assorbita a pieno carico. Nella versione Std senza pompa. / Absorbed current at full charge. Standard version without pump. 4) FLI = Potenza assorbita a pieno carico. Nella versione Std senza pompa. / Absorbed power at full charge. Standard version without pump. 5) ICF = Corrente di spunto alla partenza dell’ultimo compressore. Nella versione std senza pompa/ Max starting current (when last compressor starts) Standard version without pump 6) Valore della pressione sonora Lp(A) senza gruppo idronico, a 10 metri dalla macchina, 1 metro di altezza da terra ed in campo libero.
Noise pressure value Lp(A) without hydronic group, at 10 mt, at 1 high mt from the ground, in free field conditions 7) Connessioni ODS con attacco femmina a saldare / Welded female connections ODS
MOD. CH R290 2190 2200 2220 2230 2270 2290 2310 2330
DATI ELETTRICI / ELECTRICAL DATA
FLA (3) A 160,8 178,8 196,8 220,8 254,4 310,4 310,4 310,4
FLI (4) kW 67,8 73,1 80,5 85,6 97,0 106,2 115,4 124,0
ICF (5) A 375,8 417,8 461,8 570,8 678,4 746,40 746,4 746,40
MODULO IDRONICO(opzionale) - HYDRONIC KIT(option)
N.ro di pompe standard / No. of standard pumps - 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2
Potenza nominale pompa / Pump nominal power kW 4,00 4,00 4,00 4,00 5,50 5,50 5,50 5,50
Capacità serbatoio / Tank volume dm3 300 300 300 300 500 500 500 500
Prevalenza utile (Allestimento MH) / Available pressure (MH configuration) (1) kPa 189 186 178 177 222 211 198 187
Livello sonoro Lp(A) / Sound level Lp(A) (6) dB(A) 64 64 64 64 67 67 67 67
Diametro connessioni idrauliche / Hydraulic connections diameter (in/out) inch 3" 3" 3" 4" 4" 4" 4" 4"
DIMENSIONI E PESI / DIMENSIONS AND WEIGHTS
Lunghezza / Lenght mm 4.000 4.000 4.000 4.000 5.100 5.100 5.100 5.100
Larghezza / Depth mm 1.200 1.200 1.200 1.200 1.200 1.200 1.200 1.200
Altezza / Height mm 2.400 2.400 2.400 2.400 2.450 2.450 2.450 2.450
Peso (senza modulo idronico) / Weight (without hydronic kit) kg 1.250 1.332 1.414 1.498 1.760 1.838 1.916 1.995
19
AIR CONDITIONINGTECH LINE
Disegni dimensionali / Dimensional drawings
1200
2400
1800
MOD. CH R290 1065 - 1070
MOD. CH R290 2100 - 2120 - 2130 - 2135 - 2150 - 2160
1200
2400
2900
CH R 290 VDS 65,7 - 341 kW
20
Disegni dimensionali / Dimensional drawings2400
4000
1200
MOD. CH R290 2190 - 2200 - 2220 - 2230
MOD. CH R290 2270 - 2290 - 2310 - 2330
1200
24
50
5100
21
AIR CONDITIONINGTECH LINE CH R 290 A 66,9 - 269,9 kW
22
COMMERCIAL LINETECH LINE
CHR 29066,9-269,9 kW
23
AIR CONDITIONINGTECH LINE
CH R 290CH R 290La più ampia gamma di refrigeratori di liquido (EN14511:2013 e classe
energetica ERP 2015-2017) condensati ad aria per installazione in
esterno per ambienti commerciali, industriali e di processo
A wide range of air cooled liquid chillers (EN14511:2013 and energy
regulation ERP 2015-2017), air condensed for outdoor installation for
commercial, industrial and process enviroments
Bicold Engineering Srl da sempre realizza prodotti nel rispetto dell’ambiente
e del risparmio energetico in sintonia con direttive e normative comunitarie
e ponendo la sua attenzione sui problemi legati all’impatto ambientale
con l’obiettivo di essere in coerenza con quanto stabilito dal protocollo di
Montreal (1987), dal protocollo di Kyoto (1997) e il più recente regolamento
(UE) n.517/2014 del Parlamento e del consiglio Europeo, del 16 aprile
2014, sui gas fluorurati a effetto serra e che abroga il regolamento (CE) n.
842/2006.
La ricerca di nuovi refrigeranti a basso impatto ambientale, la limitazione
all’utilizzo e la tassazione per ragioni ambientali su alcuni refrigeranti
sintetici nei prossimi anni, hanno fatto guadagnare al propano (R290) una
alternativa naturale ai tradizionali gas refrigeranti (CFC-HCFC-HFC), ad alto
coefficiente di GWP (Global Warning Potential)
Il propano (R290), come gas refrigerante, non è penalizzato da restrizioni
o regolamenti che ne limitino l’uso, in questo modo può essere utilizzato
per qualsiasi applicazione nel settore del condizionamento, dei processi
industriali e della refrigerazione (applicazioni in media temperatura).
La progettazione è stata realizzata considerando gli elevati contenuti tecnici
in relazione all’utilizzo del propano R290 e le esigenze del mercato a cui
questo prodotto si riferisce. Il principio di base è la combinazione dell’R290
come refrigerante ecologico e il rispetto dei livelli di efficienza ed affidabilità
più elevati.
Applicazioni
• Refrigerazione (in media temperatura)
• Condizionamento
• Processo industriale
Impianti
• Refrigerazione commerciale (negozi, minimarket e supermarket)
• Refrigerazione industriale (centri logistici del freddo e industria
alimentare)
• Catering (Ristorazione)
• Condizionamento comfort
• Processo industriale
• Applicazioni speciali
Installazione
Le unità sono fornite per il funzionamento all’esterno, vengono equipaggiate
con una robusta carpenteria verniciata con vernice epossidica RAL7035
particolarmente resistente agli agenti atmosferici, che ne consente l’impiego
anche in condizioni ambientali estreme.
66,9 – 269,9 kW
H
Hgrandi collettività
large community
sanità
health
residenziale
residential
commerciale
commercial
terziario
tertiary
industriale
industrial
CH R 290 A 66,9 - 269,9 kW
24
the use of propane R290 and market demands in the relevant sector. The
basic principle lies in the use of the eco-friendly refrigerant R290 combined
with meeting the highest standards in terms of efficiency and reliability.
Applications
• Refrigeration (medium temperature application)
• Air conditioning
• Cooling process
Systems
• Commercial refrigeration (sales outlets, minimarkets and supermarkets)
• Industrial refrigeration (logistic cooling centres and food industry)
• Catering
• Air conditioning comfort
• Process cooling
• Special applications
Installation
The units are supplied for operation outdoors. In the case of outdoor
installation, they are equipped with a rugged framework finished with epoxy
paint RAL7035, particularly resistant to atmospheric agents to enable use
even in extreme environmental conditions.
Bicold Engineering Srl has always manufactured energy efficient and eco-
friendly products, in observance of the European directives and standards,
and paying special attention to issues linked to environmental impact with
the objective of meeting all requirements as specified by the protocol of
Montreal (1987) and the protocol of Kyoto (1997) in terms of environmental
emissions, as well as the most recent regulation (EU) no.517/2014 of
the European Parliament and Council, of 16 April 2014, on fluorinated
greenhouse gases, repealing regulation (EC) no. 842/2006.
The research into new refrigerants with low environmental impact, the
limitation of use and taxation for environmental reasons on a number of
synthetic refrigerants over the next few years have meant that propane
(R290) is a natural alternative to traditional refrigerants (CFC-HCFC-HFC),
with high GWP coefficient (Global Warning Potential)
Propane (R290) has attracted a great deal of interest with respect to
synthetic refrigerants (CFC-HCFC-HFC).
R290 is not subject to constraints or regulations that limit use, and therefore
can be used in Air conditioning, cooling process and refrigeration (medium
temperature application).
The design stage took into account the high technical content in relation to
25
AIR CONDITIONINGTECH LINE
CH R 290 PLUS
(in quanto questo tipo di gas è già presente in natura)
(as this gas is already present in nature)
Refrigerante al 100% rispettoso verso l’ambiente
Refrigerant 100% environmentally friendly
Refrigerante non tossico
Non toxic refrigerantRefrigerante naturale
Natural refrigerant
Refrigerante di facile e globale disponibilità
Globally and easily available refrigerant
Refrigerante con la massima sicurezza ambientaleRefrigerant with guaranteed maximum environmental safety
Refrigerante a basso costo
Low cost refrigerant
Potenziale di distruzione dell’ozono ODP (ozone depleting potential) pari a zero (assenza di CFC all’interno del refrigerante)
Ozone depletion potential (ODP) equal to zero(no CFCs in the refrigerant)
Tasso di riscaldamento globale del pianeta GWP (global warming potential) pari a 3
Global warming potential (GWP) equal to 3
Classe A in funzionamento Raffreddamento (opzionale)
A Class in cooling version (optional)
Basso contenuto di refrigerante
Lower refrigerant charge
Controllo auto adattativo che permette:
1. Limitazione spunti avviamento compressore
2. Tempo minimo di funzionamento del
compressore per il ritorno dell’olio
3. Possibilità di ridurre o eliminare l’uso di un
serbatoio dell’acqua
Adaptive self-control that allows:
1. Limitation compressor starter
2. Minimum run time of the compressor for
oil return
3. Possibility to reduce or eliminate the use
of a water tank
CH R 290 A 66,9 - 269,9 kW
26
Nuovo ventilatore ad alta efficienza con pale in tecno polimero per una ridotta emissione sonora
New high efficiency axial fans with blades in high resistance tecnopolymer, with low sound emission
Disponibile con recupero energetico parziale
integrato che consente di recuperare il
calore di condensazione che può consentire
la produzione gratuita di acqua calda a
temperatura massima 50°C per vari utilizzi:
1. Acqua calda sanitaria
2. Batterie ad acqua calda per post-
riscaldamento (centrali trattamento aria e
roof top ecc.)
3. Altri processi o lavorazioni che richiedono
acqua calda
Available with partial integrated energy recovery that allows to recover the heat of condensation in order to produce free hot water at maximum 50°C to use it for:
1. Domestic hot water2. Hot water Batteries post - heating
(air handling units and roof top units etc.)
3. Other processes or processes that require hot water
Estesi limiti di funzionamento
• Temperatura esterna 0°C / +43°C
• Produzione acqua calda +40°C / +45°C
Extended operating limits• Ambient temperature 0°C / +43°C• Hot water production +40°C / +45°C
A richiesta carpenteria
in acciaio INOX
Stainless steel version on demand
Free Cooling è il raffreddamento gratuito di un fluido grazie alla bassa temperatura
dell’ambiente esterno, senza l’attivazione di compressori con un risparmio energetico.
Free Cooling a liquid thanks to low ambient temperature that avoids to switch on the compressors and saves energy
Carpenteria saldata
Welded frame
Applicazioni a bassa temperatura acqua in funzionamento
raffrescamento fino a -5°C
Low water temperature applications in cooling operation down to -5°C
Tubazioni in acciaio inossidabile
Stailess steel piping
Separazione aeraulica tra il circuito refrigerante e il lato condensazione
Aeraulic separation between the refrigerant circuit and the condensation side
Modulazione della capacità dell’impianto ottimizzando il consumo energetico
Modulation system capacity optimizing the energy consumption
27
AIR CONDITIONINGTECH LINE
Identificazione del modello - Identificazione del modello
R290CH 2 230 VDS MH
CH MODELLI MODELS
Gruppi refrigeratori di liquido con condensazione ad ARIA con ventilatori assiali (installazione idonea all’esterno), con
compressori semi ermetici ed evaporatori a piastre
Liquid chillers AIR cooled with axial fans (for outdoor installation), with semi hermetic compressors and plates exchanger
REFRIGERANTE REFRIGERANT
Propano R290
Propane R290
ALLESTIMENTO CONFIGURATION
HE Unità ad alta efficienza con compressori più piccoli e batterie maggiorate
PHR Unità con recuperatore di calore parziale
IXF Unità con carpenteria in acciaio inox
IXWP Unità con tubazioni acqua in acciaio inox
SPBT Unità con serbatoio in acciaio inox
SDF Unità con carpenteria saldata
SE Unità con solo evaporatore. E’ compreso il pressostato differenziale a protezione dell’evaporatore.
MP Unità con evaporatore e una pompa centrifuga. E’ compreso il pressostato differenziale a protezione dell’evaporatore.
DP Unità con evaporatore e doppia pompa centrifuga. E’ compreso il pressostato differenziale a protezione dell’evaporatore.
MH Unità con modulo idronico; l’allestimento comprende una pompa centrifuga, il serbatoio di accumulo, la valvola di sicurezza acqua tarata a 3 Bar e il pressostato differenziale a protezione dell’evaporatore.
MHD Unità con modulo idronico; l’allestimento comprende la doppia pompa centrifuga, il serbatoio di accumulo, la valvola di sicurezza acqua tarata a 3 Bar e il pressostato differenziale a protezione dell’evaporatore.
HE High efficiency unit with a combination of smaller compressors and bigger condenser
PHR Unit with partial heat recovery (desuperheater)
IXF Unit with inox frame
IXWP Unit with water stainless steel pipes
SPBT Unit with buffer tank
SDF Unit with welded frame
SE Unit with evaporator only. It includes differential pressure switch for evaporator protection
MP Unit with evaporator and one centrifugal pump. It includes differential pressure switch for evaporator protection.
DP Unit with evaporator and double centrifugal pump. It includes differential pressure switch for evaporator protection.
MH Unit with hydronic modul; configuration includes one centrifugal pump, buffer tank, safety water valve (set 3 Bar) and differential pressure switch for evaporator protection.
MHD Unit with hydronic modul; configuration includes double centrifugal pump, buffer tank, safety water valve (set 3 Bar) and differential pressure switch for evaporator protection.
N. CIRCUITI FRIGORIFERI N. REFRIGERANT CIRCUIT
2 due circuiti
2 two circuits
VERSIONE VERSION
VDS di serie - A Classe A
VDS standard - A A class
R290
2
VDS
MH
TAGLIA SIZE
Potenza frigorifera [kW] alle condizioni operative nominali (temperatura acqua refrigerata +12/+7 °C temperatura aria esterna +32 °C)
Cooling capacity [kW] at nominal operating conditions (chilled water temperature +12/+7 °C outdoor air temperature +32 °C)
230
CH R 290 A 66,9 - 269,9 kW
28
Garanzia di Qualità e Risparmio Energetico
Quality and Energy Saving Guarantee
29
AIR CONDITIONINGTECH LINE
I modelli denominati CH R290 sono unità solo freddo.
Il fluido frigorigeno utilizzato è l’R290.
L’intera gamma è sostituita da un ampio numero di modelli con
potenza frigorifera da 66,9 a 269,9 kW ed è caratterizzata da
soluzioni attente all’efficienza energetica, alla silenziosità, versatilità e
alla semplicità nell’uso e la manutenzione.
I compressori utilizzati sono del tipo semi ermetico a pistoni progettati
per il funzionamento con il refrigerante R290.
I condensatori sono del tipo a batteria con tubo in rame e alette in
alluminio ad alta efficienza.
I ventilatori impiegati sono del tipo assiale a basso numero di giri
e alta efficienza realizzati in polimero ad alta resistenza, di serie è
presente un controllo di velocità dei ventilatori attraverso un regolatore
di giri a taglio di fase (opzionale elettronico).
Lo scambiatore rigenerativo è a piastre saldobrasate in acciaio
inox AISI 316 ed è termicamente isolato con materiale espanso a
cellule chiuse per una maggior protezione del compressore e per
aumentare le performance del sistema.
L’evaporatore è a piastre saldobrasate in acciaio inox AISI 316 ed è
termicamente isolato con materiale espanso a cellule chiuse.
Il circuito frigorifero include la valvola di espansione con funzione
MOP, filtro deidratatore, indicatore di passaggio e umidità, pressostati
di alta e bassa pressione e valvola di sicurezza.
La regolazione dei refrigeratori avviene mediante un controllore
elettronico a microprocessore.
Per tutti i modelli della gamma CH R290 è attiva la funzione di
“unloading per alta pressione”, che permette il funzionamento
dell’unità anche in condizioni ambientali estreme.
Le carpenterie sono costruite in lamiera di acciaio al carbonio zincata
e con verniciatura a forno con polveri epossidiche per assicurare la
migliore resistenza agli agenti atmosferici.
Il colore delle unità è il RAL 7035.
Alcuni componenti possono essere certificati Atex.
CARATTERISTICHE PRINCIPALI
CH R 290 A 66,9 - 269,9 kW
30
Models CH R290 are only cooling units.
These units work with refrigerant R290.
The whole range is composed of several models with cooling capacity
from 66,9 up to 269,9 kW and it is defined by solutions careful to
energy efficiency, soundproof, versatility and easiness of use and
maintenance.
Semi hermetic compressors designed to work with refrigerant R290.
High efficiency condenser coils are made of copper pipes and
aluminium fins.
High efficiency fans are axial type with low RPM made in high
resistance tecnopymer, there is as a standard equipment a fan speed
regulator by a speed cut phase regulator (electronic as option).
The regenerative heat exchanger is stainless steel AISI 316 brazed
plates with thermal insulation of close cells material for compressors
higher protection and to increase the performance of the system.
The evaporator is stainless steel AISI 316 brazed plates with thermal
insulation of close cells material.
Refrigerant circuit includes expansion valve with MOP function, drier
filter, sight glass, high and low pressure switches and safety valve.
Units are regulated by a microprocessor electronic board.
In all models of CH R290 there is the “high pressure unloading”
function which guarantees the operation of the units even in heavy
weather conditions.
Frames are built in galvanized metal sheet and oven painting with
epoxy powder to ensure resistance to atmospheric agents.
Color is RAL 7035.
Some components can be certified Atex.
MAIN FEATURES
31
AIR CONDITIONINGTECH LINE
1) Temperatura aria esterna 32°C; temperatura acqua ingresso-uscita evaporatore 12-7°C / In/out evaporator water 12/7 °C outside air temperature 32 °C 2) Temperatura aria esterna 25°C; temperatura acqua ingresso-uscita evaporatore 15-10°C / In/out evaporator water 15/10 °C outside air temperature 25 °C 3) FLA = Corrente assorbita a pieno carico. Nella versione Std senza pompa. / Absorbed current at full charge. Standard version without pump. 4) FLI = Potenza assorbita a pieno carico. Nella versione Std senza pompa. / Absorbed power at full charge. Standard version without pump. 5) ICF = Corrente di spunto alla partenza dell’ultimo compressore. Nella versione std senza pompa/ Max starting current (when last compressor starts) Standard version without pump 6) Valore della pressione sonora Lp(A) senza gruppo idronico, a 10 metri dalla macchina, 1 metro di altezza da terra ed in campo libero.
Noise pressure value Lp(A) without hydronic group, at 10 mt, at 1 high mt from the ground, in free field conditions 7) Connessioni ODS con attacco femmina a saldare / Welded female connections ODS
MOD. CH R290 1065 1070 2100 2120 2130 2135
PRESTAZIONI / PERFOMANCES (W 12/7°- A 32°)
Potenza frigorifera / Cooling capacity (1) kW 66,9 78,6 106,0 128,5 142,1 157,3
Potenza assorbita compressori / Compressors absorbed power (1) kW 17,6 17,9 24,0 29,6 33,6 35,8
EER (1) - 3,47 3,69 3,87 3,70 3,67 3,69
Potenza frigorifera / Cooling capacity (EN14511:2013) kW 66,5 78,2 105,5 127,9 141,4 156,6
Potenza assorbita totale / Total absorbed power (EN14511:2013) kW 19,7 21,7 27,9 35,3 39,4 43,3
EER (EN14511:2013) - 3,38 3,60 3,78 3,62 3,59 3,61
EVAPORATORE / EVAPORATOR
Tipo / Type - Piastre / Plates
N.ro / No. - 1 1 1 1 1 1
Portata acqua / Water flow (1) m3/h 11,51 13,52 18,23 22,1 24,44 27,06
Perdita di carico / Pressure drop (1) kPa 43 42 41 43 45 44
Prevalenza utile (Allestimento MP) / Available pressure (MP configuration) (1) kPa 198 200 191 178 212 204
PRESTAZIONI / PERFORMANCES (W 20/15°- A 25°)
Potenza frigorifera / Cooling capacity (2) kW 87,3 102,6 138,3 167,7 185,4 205,2
Potenza assorbita compressori / Compressors absorbed power (2) kW 18,0 18,4 24,7 30,4 34,5 36,8
EER (2) - 4,43 4,71 4,92 4,72 4,68 4,71
Potenza frigorifera / Cooling capacity (EN14511:2013) kW 86,6 101,8 137,4 166,6 184,2 203,9
Potenza assorbita totale / Total absorbed power (EN14511:2013) kW 20,4 22,6 29,0 36,6 40,8 44,9
EER (EN14511:2013) - 4,25 4,52 4,74 4,56 4,51 4,54
EVAPORATORE / EVAPORATOR
Tipo / Type - Piastre / Plates
N.ro / No. - 1 1 1 1 1 1
Portata acqua / Water flow (1) m3/h 15,02 17,65 23,79 28,84 31,89 35,29
Perdita di carico / Pressure drop (1) kPa 73 72 70 73 77 75
Prevalenza utile (Allestimento MP) / Available pressure (MP configuration) (1) kPa 140 161 145 123 153 142
COMPRESSORI / COMPRESSORS
Tipo / type Semi ermetico / Semi hermetic
N.ro / No. - 1 1 2 2 2 2
N.ro compressori / No. compressors
N.ro di circuiti frigoriferi / No. refrigerant circuits-/- 1/1 1/1 2/2 2/2 2/2 2/2
Gradini di parzializzazione / Capacity steps - 2 2 4 4 4 4
CONDENSATORE / CONDENSER
Tipo / Type Batteria alettata / Finned coil
N.ro / No. - 1 1 1 1 1 1
VENTILATORI / FANS
Tipo / Type - Assiali / Axials
N.ro/Diametro / No./Diameter - 1x800 2x800 2x800 3x800 3x800 4x800
Portata aria totale / Total air flow m3/h 21.000 42.000 42.000 63.000 63.000 84.000
CH R 290 A 66,9 - 269,9 kW
32
1) Temperatura aria esterna 32°C; temperatura acqua ingresso-uscita evaporatore 12-7°C / In/out evaporator water 12/7 °C outside air temperature 32 °C 2) Temperatura aria esterna 25°C; temperatura acqua ingresso-uscita evaporatore 15-10°C / In/out evaporator water 15/10 °C outside air temperature 25 °C 3) FLA = Corrente assorbita a pieno carico. Nella versione Std senza pompa. / Absorbed current at full charge. Standard version without pump. 4) FLI = Potenza assorbita a pieno carico. Nella versione Std senza pompa. / Absorbed power at full charge. Standard version without pump. 5) ICF = Corrente di spunto alla partenza dell’ultimo compressore. Nella versione std senza pompa/ Max starting current (when last compressor starts) Standard version without pump 6) Valore della pressione sonora Lp(A) senza gruppo idronico, a 10 metri dalla macchina, 1 metro di altezza da terra ed in campo libero.
Noise pressure value Lp(A) without hydronic group, at 10 mt, at 1 high mt from the ground, in free field conditions 7) Connessioni ODS con attacco femmina a saldare / Welded female connections ODS
MOD. CH R290 1065 1070 2100 2120 2130 2135
DATI ELETTRICI / ELECTRICAL DATA
FLA (3) A 59,6 67,2 97,2 106,8 122,8 134,4
FLI (4) kW 22,4 25,9 32,8 42,1 46,5 51,8
ICF (5) A 248,6 267,2 255,2 261,8 311,8 334,4
MODULO IDRONICO(opzionale) - HYDRONIC KIT(option)
N.ro di pompe standard / No. of standard pumps - 1/2 1/2 1/2 1/2 1/2 1/2
Potenza nominale pompa / Pump nominal power kW 1,50 2,20 2,20 2,20 3,00 3,00
Capacità serbatoio / Tank volume dm3 - - 300 300 300 300
Prevalenza utile (Allestimento MH) / Available pressure (MH configuration) (1) kPa 183 185 176 163 197 189
Livello sonoro Lp(A) / Sound level Lp(A) (6) dB(A) 58 61 61 64 64 67
Diametro connessioni idrauliche / Hydraulic connections diameter (in/out) inch 2" 2" 2 1/2" 2 1/2" 2 1/2" 2 1/2"
DIMENSIONI E PESI / DIMENSIONS AND WEIGHTS
Lunghezza / Lenght mm 1800 2900 2900 4000 4000 5100
Larghezza / Depth mm 1200 1200 1200 1200 1200 1200
Altezza / Height mm 2400 2400 2400 2400 2400 2400
Peso (senza modulo idronico) / Weight (without hydronic kit) kg 598 807 888 1350 1400 1760
33
AIR CONDITIONINGTECH LINE
1) Temperatura aria esterna 32°C; temperatura acqua ingresso-uscita evaporatore 12-7°C / In/out evaporator water 12/7 °C outside air temperature 32 °C 2) Temperatura aria esterna 25°C; temperatura acqua ingresso-uscita evaporatore 15-10°C / In/out evaporator water 15/10 °C outside air temperature 25 °C 3) FLA = Corrente assorbita a pieno carico. Nella versione Std senza pompa. / Absorbed current at full charge. Standard version without pump. 4) FLI = Potenza assorbita a pieno carico. Nella versione Std senza pompa. / Absorbed power at full charge. Standard version without pump. 5) ICF = Corrente di spunto alla partenza dell’ultimo compressore. Nella versione std senza pompa/ Max starting current (when last compressor starts) Standard version without pump 6) Valore della pressione sonora Lp(A) senza gruppo idronico, a 10 metri dalla macchina, 1 metro di altezza da terra ed in campo libero.
Noise pressure value Lp(A) without hydronic group, at 10 mt, at 1 high mt from the ground, in free field conditions 7) Connessioni ODS con attacco femmina a saldare / Welded female connections ODS
MOD. CH R290 2150 2160 2190 2200 2220 2230
PRESTAZIONI / PERFOMANCES (W 12/7°- A 32°)
Potenza frigorifera / Cooling capacity (1) kW 172,3 196,0 215,6 235,4 258,0 269,9
Potenza assorbita compressori / Compressors absorbed power (1) kW 40,2 44,6 50,8 54,8 61,5 66,7
EER (1) - 3,67 3,69 3,64 3,62 3,60 3,51
Potenza frigorifera / Cooling capacity (EN14511:2013) kW 171,6 195,1 214,7 234,4 256,9 268,8
Potenza assorbita totale / Total absorbed power (EN14511:2013) kW 47,7 54,0 60,2 66,0 72,8 78,0
EER (EN14511:2013) - 3,59 3,62 3,57 3,55 3,53 3,45
EVAPORATORE / EVAPORATOR
Tipo / Type - Piastre / Plates
N.ro / No. - 1 1 1 1 1 1
Portata acqua / Water flow (1) m3/h 29,64 33,71 37,08 40,49 44,38 46,42
Perdita di carico / Pressure drop (1) kPa 42 46 45 44 47 45
Prevalenza utile (Allestimento MP) / Available pressure (MP configuration) (1) kPa 196 202 198 194 241 238
PRESTAZIONI / PERFORMANCES (W 20/15°- A 25°)
Potenza frigorifera / Cooling capacity (2) kW 224,8 255,6 281,3 307,1 336,5 352,1
Potenza assorbita compressori / Compressors absorbed power (2) kW 41,3 45,9 52,2 56,4 63,1 68,5
EER (2) - 4,67 4,70 4,63 4,61 4,59 4,47
Potenza frigorifera / Cooling capacity (EN14511:2013) kW 223,5 254,0 279,6 305,3 334,4 350,0
Potenza assorbita totale / Total absorbed power (EN14511:2013) kW 49,4 56,0 62,4 68,4 75,4 80,8
EER (EN14511:2013) - 4,52 4,53 4,48 4,46 4,44 4,33
EVAPORATORE / EVAPORATOR
Tipo / Type - Piastre / Plates
N.ro / No. - 1 1 1 1 1 1
Portata acqua / Water flow (1) m3/h 38,67 43,96 48,38 52,82 57,88 60,56
Perdita di carico / Pressure drop (1) kPa 72 78 77 75 80 77
Prevalenza utile (Allestimento MP) / Available pressure (MP configuration) (1) kPa 131 152 144 135 171 166
COMPRESSORI / COMPRESSORS
Tipo / type Semi ermetico / Semi hermetic
N.ro / No. - 2 2 2 2 2 2
N.ro compressori / No. compressors
N.ro di circuiti frigoriferi / No. refrigerant circuits-/- 2/2 2/2 2/2 2/2 2/2 2/2
Gradini di parzializzazione / Capacity steps - 4 4 4 4 4 4
CONDENSATORE / CONDENSER
Tipo / Type Batteria alettata / Finned coil
N.ro / No. - 1 1 1 1 1 1
VENTILATORI / FANS
Tipo / Type - Assiali / Axials
N.ro/Diametro / No./Diameter - 4x800 5x800 5x800 6x800 6x800 6x800
Portata aria totale / Total air flow m3/h 84.000 105.000 105.000 126.000 126.000 126.000
CH R 290 A 66,9 - 269,9 kW
34
1) Temperatura aria esterna 32°C; temperatura acqua ingresso-uscita evaporatore 12-7°C / In/out evaporator water 12/7 °C outside air temperature 32 °C 2) Temperatura aria esterna 25°C; temperatura acqua ingresso-uscita evaporatore 15-10°C / In/out evaporator water 15/10 °C outside air temperature 25 °C 3) FLA = Corrente assorbita a pieno carico. Nella versione Std senza pompa. / Absorbed current at full charge. Standard version without pump. 4) FLI = Potenza assorbita a pieno carico. Nella versione Std senza pompa. / Absorbed power at full charge. Standard version without pump. 5) ICF = Corrente di spunto alla partenza dell’ultimo compressore. Nella versione std senza pompa/ Max starting current (when last compressor starts) Standard version without pump 6) Valore della pressione sonora Lp(A) senza gruppo idronico, a 10 metri dalla macchina, 1 metro di altezza da terra ed in campo libero.
Noise pressure value Lp(A) without hydronic group, at 10 mt, at 1 high mt from the ground, in free field conditions 7) Connessioni ODS con attacco femmina a saldare / Welded female connections ODS
MOD. CH R290 2150 2160 2190 2200 2220 2230
DATI ELETTRICI / ELECTRICAL DATA
FLA (3) A 134,4 150,0 168,0 189,6 207,6 231,6
FLI (4) kW 56,7 64,4 71,2 78,2 85,6 90,7
ICF (5) A 334,4 344,0 383,0 428,6 472,6 581,6
MODULO IDRONICO(opzionale) - HYDRONIC KIT(option)
N.ro di pompe standard / No. of standard pumps - 1/2 1/2 1/2 1/2 1/2 1/2
Potenza nominale pompa / Pump nominal power kW 3,00 4,00 4,00 4,00 5,50 5,50
Capacità serbatoio / Tank volume dm3 300 300 300 300 300 300
Prevalenza utile (Allestimento MH) / Available pressure (MH configuration) (1) kPa 181 187 183 179 226 223
Livello sonoro Lp(A) / Sound level Lp(A) (6) dB(A) 67 69 69 69 69 69
Diametro connessioni idrauliche / Hydraulic connections diameter (in/out) inch 2" 1/2 3" 3" 3" 3" 4"
DIMENSIONI E PESI / DIMENSIONS AND WEIGHTS
Lunghezza / Lenght mm 5100 6200 6200 7300 7300 7300
Larghezza / Depth mm 1200 1200 1200 1200 1200 1200
Altezza / Height mm 2400 2400 2400 2400 2400 2400
Peso (senza modulo idronico) / Weight (without hydronic kit) kg 1877 2030 2100 2230 2241 2302
35
AIR CONDITIONINGTECH LINE
Disegni dimensionali / Dimensional drawings
1200
2400
1800
MOD. CH R290 1065
MOD. CH R290 1070 - 2100
1200
2400
2900
CH R 290 A 66,9 - 269,9 kW
36
Disegni dimensionali / Dimensional drawings2400
4000
1200
2400
4000
1200
MOD. CH R290 2120 - 2130
MOD. CH R290 2135 - 2150
37
AIR CONDITIONINGTECH LINE
Disegni dimensionali / Dimensional drawings
MOD. CH R290 2160 - 2190
CH R 290 A 66,9 - 269,9 kW
38
Disegni dimensionali / Dimensional drawings
MOD. CH R290 2200 - 2220 - 2300
39
AIR CONDITIONINGTECH LINE CH R 290 FC VDS 71,9 - 373,3 kW
40
COMMERCIAL LINETECH LINE
CHR 290 FC 71,9-373,3 kW
41
AIR CONDITIONINGTECH LINE
CH R 290 FCCH R 290 FCLa più ampia gamma di refrigeratori di liquido (EN14511:2013 e classe
energetica ERP 2015-2017) condensati ad aria per installazione in
esterno per ambienti industriali e di processo
A wide range of air cooled liquid chillers (EN14511:2013 and energy
regulation ERP 2015-2017), air condensed for outdoor installation for
industrial and process enviroments
Bicold Engineering Srl da sempre realizza prodotti nel rispetto dell’ambiente
e del risparmio energetico in sintonia con direttive e normative comunitarie
e ponendo la sua attenzione sui problemi legati all’impatto ambientale
con l’obiettivo di essere in coerenza con quanto stabilito dal protocollo di
Montreal (1987), dal protocollo di Kyoto (1997) e il più recente regolamento
(UE) n.517/2014 del Parlamento e del consiglio Europeo, del 16 aprile
2014, sui gas fluorurati a effetto serra e che abroga il regolamento (CE) n.
842/2006.
La ricerca di nuovi refrigeranti a basso impatto ambientale, la limitazione
all’utilizzo e la tassazione per ragioni ambientali su alcuni refrigeranti
sintetici nei prossimi anni, hanno fatto guadagnare al propano (R290) una
alternativa naturale ai tradizionali gas refrigeranti (CFC-HCFC-HFC), ad alto
coefficiente di GWP (Global Warning Potential)
Il propano (R290), come gas refrigerante, non è penalizzato da restrizioni
o regolamenti che ne limitino l’uso, in questo modo può essere utilizzato
per qualsiasi applicazione nel settore del condizionamento, dei processi
industriali e della refrigerazione (applicazioni in media temperatura).
La progettazione è stata realizzata considerando gli elevati contenuti tecnici
in relazione all’utilizzo del propano R290 e le esigenze del mercato a cui
questo prodotto si riferisce. Il principio di base è la combinazione dell’R290
come refrigerante ecologico e il rispetto dei livelli di efficienza ed affidabilità
più elevati.
Applicazioni
• Refrigerazione (in media temperatura)
• Condizionamento
• Processo industriale
Impianti
• Refrigerazione commerciale (negozi, minimarket e supermarket)
• Refrigerazione industriale (centri logistici del freddo e industria
alimentare)
• Catering (Ristorazione)
• Condizionamento comfort
• Processo industriale
• Applicazioni speciali
Installazione
Le unità sono fornite per il funzionamento all’esterno, vengono equipaggiate
con una robusta carpenteria verniciata con vernice epossidica RAL7035
particolarmente resistente agli agenti atmosferici, che ne consente l’impiego
anche in condizioni ambientali estreme.
71,9 - 373,3 kW
H
Hgrandi collettività
large community
sanità
health
terziario
tertiary
industriale
industrial
CH R 290 FC VDS 71,9 - 373,3 kW
42
the use of propane R290 and market demands in the relevant sector. The
basic principle lies in the use of the eco-friendly refrigerant R290 combined
with meeting the highest standards in terms of efficiency and reliability.
Applications
• Refrigeration (medium temperature application)
• Air conditioning
• Cooling process
Systems
• Commercial refrigeration (sales outlets, minimarkets and supermarkets)
• Industrial refrigeration (logistic cooling centres and food industry)
• Catering
• Air conditioning comfort
• Process cooling
• Special applications
Installation
The units are supplied for operation outdoors. In the case of outdoor
installation, they are equipped with a rugged framework finished with epoxy
paint RAL7035, particularly resistant to atmospheric agents to enable use
even in extreme environmental conditions.
Bicold Engineering Srl has always manufactured energy efficient and eco-
friendly products, in observance of the European directives and standards,
and paying special attention to issues linked to environmental impact with
the objective of meeting all requirements as specified by the protocol of
Montreal (1987) and the protocol of Kyoto (1997) in terms of environmental
emissions, as well as the most recent regulation (EU) no.517/2014 of
the European Parliament and Council, of 16 April 2014, on fluorinated
greenhouse gases, repealing regulation (EC) no. 842/2006.
The research into new refrigerants with low environmental impact, the
limitation of use and taxation for environmental reasons on a number of
synthetic refrigerants over the next few years have meant that propane
(R290) is a natural alternative to traditional refrigerants (CFC-HCFC-HFC),
with high GWP coefficient (Global Warning Potential)
Propane (R290) has attracted a great deal of interest with respect to
synthetic refrigerants (CFC-HCFC-HFC).
R290 is not subject to constraints or regulations that limit use, and therefore
can be used in Air conditioning, cooling process and refrigeration (medium
temperature application).
The design stage took into account the high technical content in relation to
43
AIR CONDITIONINGTECH LINE
CH R 290 PLUS
(in quanto questo tipo di gas è già presente in natura)
(as this gas is already present in nature)
Refrigerante al 100% rispettoso verso l’ambiente
Refrigerant 100% environmentally friendly
Refrigerante non tossico
Non toxic refrigerantRefrigerante naturale
Natural refrigerant
Refrigerante di facile e globale disponibilità
Globally and easily available refrigerant
Refrigerante con la massima sicurezza ambientaleRefrigerant with guaranteed maximum environmental safety
Refrigerante a basso costo
Low cost refrigerant
Potenziale di distruzione dell’ozono ODP (ozone depleting potential) pari a zero (assenza di CFC all’interno del refrigerante)
Ozone depletion potential (ODP) equal to zero(no CFCs in the refrigerant)
Tasso di riscaldamento globale del pianeta GWP (global warming potential) pari a 3
Global warming potential (GWP) equal to 3
Classe A in funzionamento Raffreddamento (opzionale)
A Class in cooling version (optional)
Basso contenuto di refrigerante
Lower refrigerant charge
Controllo auto adattativo che permette:
1. Limitazione spunti avviamento compressore
2. Tempo minimo di funzionamento del
compressore per il ritorno dell’olio
3. Possibilità di ridurre o eliminare l’uso di un
serbatoio dell’acqua
Adaptive self-control that allows:
1. Limitation compressor starter
2. Minimum run time of the compressor for
oil return
3. Possibility to reduce or eliminate the use
of a water tank
CH R 290 FC VDS 71,9 - 373,3 kW
44
Nuovo ventilatore ad alta efficienza con pale in tecno polimero per una ridotta emissione sonora
New high efficiency axial fans with blades in high resistance tecnopolymer, with low sound emission
Disponibile con recupero energetico parziale
integrato che consente di recuperare il
calore di condensazione che può consentire
la produzione gratuita di acqua calda a
temperatura massima 50°C per vari utilizzi:
1. Acqua calda sanitaria
2. Batterie ad acqua calda per post-
riscaldamento (centrali trattamento aria e
roof top ecc.)
3. Altri processi o lavorazioni che richiedono
acqua calda
Available with partial integrated energy recovery that allows to recover the heat of condensation in order to produce free hot water at maximum 50°C to use it for:
1. Domestic hot water2. Hot water Batteries post - heating
(air handling units and roof top units etc.)
3. Other processes or processes that require hot water
Estesi limiti di funzionamento
• Temperatura esterna 0°C / +43°C
• Produzione acqua calda +40°C / +45°C
Extended operating limits• Ambient temperature 0°C / +43°C• Hot water production +40°C / +45°C
A richiesta carpenteria
in acciaio INOX
Stainless steel version on demand
Free Cooling è il raffreddamento gratuito di un fluido grazie alla bassa temperatura
dell’ambiente esterno, senza l’attivazione di compressori con un risparmio energetico.
Free Cooling a liquid thanks to low ambient temperature that avoids to switch on the compressors and saves energy
Carpenteria saldata
Welded frame
Applicazioni a bassa temperatura acqua in funzionamento
raffrescamento fino a -5°C
Low water temperature applications in cooling operation down to -5°C
Tubazioni in acciaio inossidabile
Stailess steel piping
Separazione aeraulica tra il circuito refrigerante e il lato condensazione
Aeraulic separation between the refrigerant circuit and the condensation side
Modulazione della capacità dell’impianto ottimizzando il consumo energetico
Modulation system capacity optimizing the energy consumption
45
AIR CONDITIONINGTECH LINE
Identificazione del modello - Identificazione del modello
R290CH FC 2 230 VDS MH
CH MODELLI MODELS
Gruppi refrigeratori di liquido con condensazione ad ARIA con ventilatori assiali (installazione idonea all’esterno), con
compressori semi ermetici ed evaporatori a piastre
Liquid chillers AIR cooled with axial fans (for outdoor installation), with semi hermetic compressors and plates exchanger
REFRIGERANTE REFRIGERANT
Propano R290
Propane R290
FREE COOLING
ALLESTIMENTO CONFIGURATION
HE Unità ad alta efficienza con compressori più piccoli e batterie maggiorate
PHR Unità con recuperatore di calore parziale
IXF Unità con carpenteria in acciaio inox
IXWP Unità con tubazioni acqua in acciaio inox
SPBT Unità con serbatoio in acciaio inox
SDF Unità con carpenteria saldata
SE Unità con solo evaporatore. E’ compreso il pressostato differenziale a protezione dell’evaporatore.
MP Unità con evaporatore e una pompa centrifuga. E’ compreso il pressostato differenziale a protezione dell’evaporatore.
DP Unità con evaporatore e doppia pompa centrifuga. E’ compreso il pressostato differenziale a protezione dell’evaporatore.
MH Unità con modulo idronico; l’allestimento comprende una pompa centrifuga, il serbatoio di accumulo, la valvola di sicurezza acqua tarata a 3 Bar e il pressostato differenziale a protezione dell’evaporatore.
MHD Unità con modulo idronico; l’allestimento comprende la doppia pompa centrifuga, il serbatoio di accumulo, la valvola di sicurezza acqua tarata a 3 Bar e il pressostato differenziale a protezione dell’evaporatore.
HE High efficiency unit with a combination of smaller compressors and bigger condenser
PHR Unit with partial heat recovery (desuperheater)
IXF Unit with inox frame
IXWP Unit with water stainless steel pipes
SPBT Unit with buffer tank
SDF Unit with welded frame
SE Unit with evaporator only. It includes differential pressure switch for evaporator protection
MP Unit with evaporator and one centrifugal pump. It includes differential pressure switch for evaporator protection.
DP Unit with evaporator and double centrifugal pump. It includes differential pressure switch for evaporator protection.
MH Unit with hydronic modul; configuration includes one centrifugal pump, buffer tank, safety water valve (set 3 Bar) and differential pressure switch for evaporator protection.
MHD Unit with hydronic modul; configuration includes double centrifugal pump, buffer tank, safety water valve (set 3 Bar) and differential pressure switch for evaporator protection.
N. CIRCUITI FRIGORIFERI N. REFRIGERANT CIRCUIT
2 due circuiti
2 two circuits
VERSIONE VERSION
VDS di serie - A Classe A
VDS standard - A A class
R290
FC
2
VDS
MH
TAGLIA SIZE
Potenza frigorifera [kW] alle condizioni operative nominali (temperatura acqua refrigerata +12/+7 °C temperatura aria esterna +32 °C)
Cooling capacity [kW] at nominal operating conditions (chilled water temperature +12/+7 °C outdoor air temperature +32 °C)
230
CH R 290 FC VDS 71,9 - 373,3 kW
46
Garanzia di Qualità e Risparmio Energetico
Quality and Energy Saving Guarantee
47
AIR CONDITIONINGTECH LINE
I modelli denominati CH R290 sono unità solo freddo.
Il fluido frigorigeno utilizzato è l’R290.
L’intera gamma è sostituita da un ampio numero di modelli con
potenza frigorifera da 71,9 a 373,3 kW ed è caratterizzata da
soluzioni attente all’efficienza energetica, alla silenziosità, versatilità e
alla semplicità nell’uso e la manutenzione.
I compressori utilizzati sono del tipo semi ermetico a pistoni progettati
per il funzionamento con il refrigerante R290.
I condensatori sono del tipo a batteria con tubo in rame e alette in
alluminio ad alta efficienza.
I ventilatori impiegati sono del tipo assiale a basso numero di giri
e alta efficienza realizzati in polimero ad alta resistenza, di serie è
presente un controllo di velocità dei ventilatori attraverso un regolatore
di giri a taglio di fase (opzionale elettronico).
Lo scambiatore rigenerativo è a piastre saldobrasate in acciaio
inox AISI 316 ed è termicamente isolato con materiale espanso a
cellule chiuse per una maggior protezione del compressore e per
aumentare le performance del sistema.
L’evaporatore è a piastre saldobrasate in acciaio inox AISI 316 ed è
termicamente isolato con materiale espanso a cellule chiuse.
Il circuito frigorifero include la valvola di espansione con funzione
MOP, filtro deidratatore, indicatore di passaggio e umidità, pressostati
di alta e bassa pressione e valvola di sicurezza.
Il Free Cooling include la batteria ad acqua, la valvola a tre vie On/
Off e la regolazione elettronica. La regolazione dei ventilatori avviene
in funzione della pressione di condensazione quando il compressore
è acceso e in funzione della temperatura dell’acqua quando il Free
Cooling è attivo e il compressore è spento. Durante il funzionamento
misto, con compressore acceso e Free Cooling attivo, i ventilatori
regolano in funzione della pressione di condensazione.
La regolazione dei refrigeratori avviene mediante un controllore
elettronico a microprocessore.
Per tutti i modelli della gamma CH R290 è attiva la funzione di
“unloading per alta pressione”, che permette il funzionamento
dell’unità anche in condizioni ambientali estreme.
Le carpenterie sono costruite in lamiera di acciaio al carbonio zincata
e con verniciatura a forno con polveri epossidiche per assicurare la
migliore resistenza agli agenti atmosferici.
Il colore delle unità è il RAL 7035.
Alcuni componenti possono essere certificati Atex.
CARATTERISTICHE PRINCIPALI
La logica di regolazione dei ventilatori di condensazione per unità Free
Cooling CHR 290 FC prevede tre modalità di funzionamento:
1) Funzionamento “Chiller”: raffreddamento con compressori accesi e
valvola acqua chiusa. La regolazione dei ventilatori avviene in funzione
della pressione di condensazione, la valvola acqua è chiusa (la temperatura
esterna non permette uno scambio termico vantaggioso).
2) Funzionamento “Free Cooling”: raffreddamento con compressori spenti
e valvola acqua aperta. La regolazione dei ventilatori avviene in funzione
della temperatura acqua in uscita dell’unità, la valvola acqua è aperta (la
temperatura esterna permette uno scambio termico vantaggioso).
3) Funzionamento “Free Cooling + Chiller”: detto “combinato”, i
compressori possono essere accesi o spenti e valvola acqua aperta.
La regolazione dei ventilatori avviene in funzione della pressione di
condensazione a compressori accesi, mentre la regolazione dei ventilatori
a compressori spenti avviene in funzione della temperatura acqua in uscita
dell’unità, la valvola acqua è aperta (la temperatura esterna permette uno
scambio termico parzialmente vantaggioso)
REGOLAZIONE VENTILATORI
CH R 290 FC VDS 71,9 - 373,3 kW
48
Models CH R290 are only cooling units.
These units work with refrigerant R290.
The whole range is composed of several models with cooling capacity
from 71,9 up to 373,3 kW and it is defined by solutions careful to
energy efficiency, soundproof, versatility and easiness of use and
maintenance.
Semi hermetic compressors designed to work with refrigerant R290.
High efficiency condenser coils are made of copper pipes and
aluminium fins.
High efficiency fans are axial type with low RPM made in high
resistance tecnopymer, there is as a standard equipment a fan speed
regulator by a speed cut phase regulator (electronic as option).
The regenerative heat exchanger is stainless steel AISI 316 brazed
plates with thermal insulation of close cells material for compressors
higher protection and to increase the performance of the system.
The evaporator is stainless steel AISI 316 brazed plates with thermal
insulation of close cells material.
Refrigerant circuit includes expansion valve with MOP function, drier
filter, sight glass, high and low pressure switches and safety valve.
Free cooling configuration includes water coil, On/Off three ways
water valve and electronic regulation. Fans regulation is according
on condensing pressure when compressor is on, and according on
water temperature when Free Cooling is activated and compressor is
switched off. During combined operation, with compressor on and Free
Cooling activated, fans speed depends on condensing pressure.
Units are regulated by a microprocessor electronic board.
In all models of CH R290 there is the “high pressure unloading”
function which guarantees the operation of the units even in heavy
weather conditions.
Frames are built in galvanized metal sheet and oven painting with
epoxy powder to ensure resistance to atmospheric agents.
Color is RAL 7035.
Some components can be certified Atex.
MAIN FEATURES
There are 3 modalities for the regulation of condensing fans in CHR 290
FC Free Cooling units:
1) “Chiller” modality: cooling with the compressors switched on and
the water valve closed. The regulation of condensing fans speed occurs
according to the condensing pressure. The water valve is closed (the external
temperature does not allow a favorable heat exchange).
2) “Free Cooling” modality: cooling with the compressors switched off
and the water valve open. The regulation of condensing fans speed occurs
according to the outlet water temperature of the unit. The water valve is
open (the external temperature allows a favorable heat exchange).
3) “Free Cooling + Chiller” modality - said “combined modality”:
the compressors can be switched on or off, the water valve is open. The
regulation of condensing fans speed occurs according to the condensing
pressure, when the compressors are switched on; on the contrary, it occurs
according to the outlet water temperature of the unit, when the compressors
are switched off. The water valve is open ( the external temperature allows a
partially favorable heat exchange).
FANS REGULATION
49
AIR CONDITIONINGTECH LINE
1) Temperatura aria esterna 30°C; temperatura acqua ingresso-uscita evaporatore 15-10°C / In/out evaporator, water 15-10 °C outside air temperature 30°C2) Temperatura aria esterna 5°C; temperatura acqua ingresso evaporatore 15°C / In evaporator, water 15°C outside air temperature 5°C3) Temperatura aria esterna 0°C; temperatura acqua ingresso evaporatore 15°C / In evaporator, water 15°C outside air temperature 0°C4) Prevalenza utile (Allestimento MP) con perdite di carico batteria free cooling, scambiatore a piastre, valvola a tre vie e circuito idraulico/Available pressure (MP configuration) with pressure drop of free
cooling coil, plates evaporator, 3 ways valve and hydraulic circuit 5) FLA = Corrente assorbita a pieno carico. Nella versione Std senza pompa. / Absorbed current at full charge. Standard version without pump.6) FLI = Potenza assorbita a pieno carico. Nella versione Std senza pompa. / Absorbed power at full charge. Standard version without pump.7) ICF = Corrente di spunto alla partenza dell’ultimo compressore. Nella versione std senza pompa/ Max starting current (when last compressor starts) Standard version without pump8) Valore della pressione sonora Lp(A) senza gruppo idronico, a 10 metri dalla macchina, 1 metro di altezza da terra ed in campo libero / Noise pressure value Lp(A) without hydronic group, at 10 mt, at 1
high mt from the ground, in free field conditions 9) Connessioni ODS con attacco femmina a saldare / Welded female connections ODS
MOD. CH R290 FC 1065 1070 2100 2120 2130 2135 2150 2160
PRESTAZIONI / PERFOMANCES (W 15/10°- A 30°)
Potenza frigorifera / Cooling capacity (1) kW 71,9 76,9 113,9 131,7 143,8 151,8 166,0 179,5
Potenza assorbita compressori / Compressors absorbed power kW 17,9 19,6 24,4 31,2 35,7 39,5 44,1 50,2
PRESTAZIONI (Free Cooling) / PERFORMANCES (Free Cooling)
Potenza frigorifera / Cooling capacity (W15°; A5°) (2) kW 47,0 47,0 94,0 94,0 94,0 94,0 94,0 94,0
Potenza frigorifera / Cooling capacity (W15°; A0°) (3) kW 70,5 70,5 141,0 141,0 141,0 141,0 141,0 141,0
Temperatura Free Cooling totale / Total Free Cooling temperature °C -0,3 -1,4 2,9 1,0 -0,3 -1,1 -2,7 -4,1
Perdite di carico batteria FC / Pressure drop FC water coil kPa 30 30 30 30 30 30 30 30
Perdita di carico valvola acqua 3 vie / Pressure drop 3 ways water valve kPa 24 24 24 24 24 24 24 24
Prevalenza utile (Allestimento MP) / Available pressure (MP configuration) (4) kPa 125 120 121 111 147 140 133 122
Numero di ventilatori sezione FC / Number of fans section FC - 1 1 2 2 2 2 2 2
Potenza assorbita sezione ventilante FC / Fans absorbed power section FC kW 1,7 1,7 3,4 3,4 3,4 3,4 3,4 3,4
EVAPORATORE / EVAPORATOR
Tipo / Type - Piastre / Plates
N.ro / No. - 1 1 1 1 1 1 1 1
Portata acqua / Water flow (1) m3/h 12,4 13,2 19,6 22,7 24,7 26,1 28,6 30,9
Perdita di carico / Pressure drop (1) kPa 46 44 43 44 45 47 45 48
Prevalenza utile (Allestimento MP) / Available pressure (MP configuration) (1) kPa 155 150 151 141 177 170 163 152
COMPRESSORI / COMPRESSORS
Tipo / type Semi ermetico / Semi hermetic
N.ro / No. - 1 1 2 2 2 2 2 2
N.ro compressori / No. compressors
N.ro di circuiti frigoriferi / No. refrigerant circuits-/- 1/1 1/1 2/2 2/2 2/2 2/2 2/2 2/2
Gradini di parzializzazione / Capacity steps - 2 2 4 4 4 4 4 4
CONDENSATORE / CONDENSER
Tipo / Type Batteria alettata / Finned coil
N.ro / No. - 1 1 1 1 1 1 1 1
VENTILATORI / FANS
Tipo / Type - Assiali / Axials
N.ro/Diametro / No./Diameter - 2x800 2x800 4x800 4x800 4x800 4x800 4x800 4x800
Portata aria totale / Total air flow m3/h 42.000 42.000 84.000 84.000 84.000 84.000 84.000 84.000
CH R 290 FC VDS 71,9 - 373,3 kW
50
1) Temperatura aria esterna 30°C; temperatura acqua ingresso-uscita evaporatore 15-10°C / In/out evaporator, water 15-10 °C outside air temperature 30°C2) Temperatura aria esterna 5°C; temperatura acqua ingresso evaporatore 15°C / In evaporator, water 15°C outside air temperature 5°C3) Temperatura aria esterna 0°C; temperatura acqua ingresso evaporatore 15°C / In evaporator, water 15°C outside air temperature 0°C4) Prevalenza utile (Allestimento MP) con perdite di carico batteria free cooling, scambiatore a piastre, valvola a tre vie e circuito idraulico/Available pressure (MP configuration) with pressure drop of free
cooling coil, plates evaporator, 3 ways valve and hydraulic circuit 5) FLA = Corrente assorbita a pieno carico. Nella versione Std senza pompa. / Absorbed current at full charge. Standard version without pump.6) FLI = Potenza assorbita a pieno carico. Nella versione Std senza pompa. / Absorbed power at full charge. Standard version without pump.7) ICF = Corrente di spunto alla partenza dell’ultimo compressore. Nella versione std senza pompa/ Max starting current (when last compressor starts) Standard version without pump8) Valore della pressione sonora Lp(A) senza gruppo idronico, a 10 metri dalla macchina, 1 metro di altezza da terra ed in campo libero / Noise pressure value Lp(A) without hydronic group, at 10 mt, at 1
high mt from the ground, in free field conditions 9) Connessioni ODS con attacco femmina a saldare / Welded female connections ODS
MOD. CH R290 FC 1065 1070 2100 2120 2130 2135 2150 2160
DATI ELETTRICI / ELECTRICAL DATA
FLA (5) A 63,2 67,2 104,4 110,4 126,4 134,4 134,4 146,4
FLI (6) kW 24,1 25,9 36,2 43,8 48,2 51,8 56,7 62,7
ICF (7) A 252,2 267,2 262,4 265,4 315,4 334,4 334,4 340,4
MODULO IDRONICO(opzionale) - HYDRONIC KIT(option)
N.ro di pompe standard / No. of standard pumps - 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2
Potenza nominale pompa / Pump nominal power kW 1,50 1,50 2,20 2,20 3,00 3,00 3,00 3,00
Capacità serbatoio / Tank volume dm3 - - 300 300 300 300 300 300
Prevalenza utile (Allestimento MH) / Available pressure (MH configuration) (1) kPa 140 135 136 126 162 155 148 137
Livello sonoro Lp(A) / Sound level Lp(A) (8) dB(A) 61 61 67 67 67 67 67 67
Diametro connessioni idrauliche / Hydraulic connections diameter (in/out) (9) inch 2" 2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 3"
DIMENSIONI E PESI / DIMENSIONS AND WEIGHTS
Lunghezza / Lenght mm 3.350 3.350 5.550 5.550 5.550 5.550 5.550 5.550
Larghezza / Depth mm 1.200 1.200 1.200 1.200 1.200 1.200 1.200 1.200
Altezza / Height mm 2.400 2.400 2.400 2.400 2.400 2.400 2.400 2.400
Peso (senza modulo idronico) / Weight (without hydronic kit) kg 987 1.009 1.955 1.980 2.001 2.030 2.050 2.085
51
AIR CONDITIONINGTECH LINE
1) Temperatura aria esterna 30°C; temperatura acqua ingresso-uscita evaporatore 15-10°C / In/out evaporator, water 15-10 °C outside air temperature 30°C2) Temperatura aria esterna 5°C; temperatura acqua ingresso evaporatore 15°C / In evaporator, water 15°C outside air temperature 5°C3) Temperatura aria esterna 0°C; temperatura acqua ingresso evaporatore 15°C / In evaporator, water 15°C outside air temperature 0°C4) Prevalenza utile (Allestimento MP) con perdite di carico batteria free cooling, scambiatore a piastre, valvola a tre vie e circuito idraulico/Available pressure (MP configuration) with pressure drop of free
cooling coil, plates evaporator, 3 ways valve and hydraulic circuit 5) FLA = Corrente assorbita a pieno carico. Nella versione Std senza pompa. / Absorbed current at full charge. Standard version without pump.6) FLI = Potenza assorbita a pieno carico. Nella versione Std senza pompa. / Absorbed power at full charge. Standard version without pump.7) ICF = Corrente di spunto alla partenza dell’ultimo compressore. Nella versione std senza pompa/ Max starting current (when last compressor starts) Standard version without pump8) Valore della pressione sonora Lp(A) senza gruppo idronico, a 10 metri dalla macchina, 1 metro di altezza da terra ed in campo libero / Noise pressure value Lp(A) without hydronic group, at 10 mt, at 1
high mt from the ground, in free field conditions 9) Connessioni ODS con attacco femmina a saldare / Welded female connections ODS
MOD. CH R290 FC 2190 2200 2220 2230 2270 2290 2310 2330
PRESTAZIONI / PERFOMANCES (W 15/10°- A 30°)
Potenza frigorifera / Cooling capacity (1) kW 212,7 227,7 249,3 260,3 300,0 326,2 351,5 373,3
Potenza assorbita compressori / Compressors absorbed power kW 54,7 59,8 66,9 72,1 79,7 88,5 97,3 105,6
PRESTAZIONI (Free Cooling) / PERFORMANCES (Free Cooling)
Potenza frigorifera / Cooling capacity (W15°; A5°) (2) kW 141,0 141,0 141,0 141,0 188,0 188,0 188,0 188,0
Potenza frigorifera / Cooling capacity (W15°; A0°) (3) kW 211,5 211,5 211,5 211,5 282,0 282,0 282,0 282,0
Temperatura Free Cooling totale / Total Free Cooling temperature °C -0,1 -1,1 -2,7 -3,5 -1,0 -2,4 -3,7 -4,9
Perdite di carico batteria FC / Pressure drop FC water coil kPa 30 30 30 30 30 30 30 30
Perdita di carico valvola acqua 3 vie / Pressure drop 3 ways water valve kPa 24 24 24 24 24 24 24 24
Prevalenza utile (Allestimento MP) / Available pressure (MP configuration) (4) kPa 133 131 122 120 160 148 131 119
Numero di ventilatori sezione FC / Number of fans section FC - 3 3 3 3 4 4 4 4
Potenza assorbita sezione ventilante FC / Fans absorbed power section FC kW 5,1 5,1 5,1 5,1 6,8 6,8 6,8 6,8
EVAPORATORE / EVAPORATOR
Tipo / Type - Piastre / Plates
N.ro / No. - 1 1 1 1 1 1 1 1
Portata acqua / Water flow (1) m3/h 36,6 39,2 42,9 44,8 51,6 56,1 60,5 64,2
Perdita di carico / Pressure drop (1) kPa 47 45 47 45 46 45 48 47
Prevalenza utile (Allestimento MP) / Available pressure (MP configuration) (1) kPa 163 161 152 150 190 178 161 149
COMPRESSORI / COMPRESSORS
Tipo / type Semi ermetico / Semi hermetic
N.ro / No. - 2 2 2 2 2 2 2 2
N.ro compressori / No. compressors
N.ro di circuiti frigoriferi / No. refrigerant circuits-/- 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2
Gradini di parzializzazione / Capacity steps - 4 4 4 4 4 4 4 4
CONDENSATORE / CONDENSER
Tipo / Type Batteria alettata / Finned coil
N.ro / No. - 1 1 1 1 1 1 1 1
VENTILATORI / FANS
Tipo / Type - Assiali / Axials
N.ro/Diametro / No./Diameter - 6x800 6x800 6x800 6x800 8x800 8x800 8x800 8x800
Portata aria totale / Total air flow m3/h 126.000 126.000 126.000 126.000 168.000 168.000 168.000 168.000
CH R 290 FC VDS 71,9 - 373,3 kW
52
1) Temperatura aria esterna 30°C; temperatura acqua ingresso-uscita evaporatore 15-10°C / In/out evaporator, water 15-10 °C outside air temperature 30°C2) Temperatura aria esterna 5°C; temperatura acqua ingresso evaporatore 15°C / In evaporator, water 15°C outside air temperature 5°C3) Temperatura aria esterna 0°C; temperatura acqua ingresso evaporatore 15°C / In evaporator, water 15°C outside air temperature 0°C4) Prevalenza utile (Allestimento MP) con perdite di carico batteria free cooling, scambiatore a piastre, valvola a tre vie e circuito idraulico/Available pressure (MP configuration) with pressure drop of free
cooling coil, plates evaporator, 3 ways valve and hydraulic circuit 5) FLA = Corrente assorbita a pieno carico. Nella versione Std senza pompa. / Absorbed current at full charge. Standard version without pump.6) FLI = Potenza assorbita a pieno carico. Nella versione Std senza pompa. / Absorbed power at full charge. Standard version without pump.7) ICF = Corrente di spunto alla partenza dell’ultimo compressore. Nella versione std senza pompa/ Max starting current (when last compressor starts) Standard version without pump8) Valore della pressione sonora Lp(A) senza gruppo idronico, a 10 metri dalla macchina, 1 metro di altezza da terra ed in campo libero / Noise pressure value Lp(A) without hydronic group, at 10 mt, at 1
high mt from the ground, in free field conditions 9) Connessioni ODS con attacco femmina a saldare / Welded female connections ODS
MOD. CH R290 FC 2190 2200 2220 2230 2270 2290 2310 2330
DATI ELETTRICI / ELECTRICAL DATA
FLA (5) A 171,6 189,6 207,6 231,6 268,8 324,8 324,8 324,8
FLI (6) kW 72,9 78,2 85,6 90,7 103,8 113,0 122,2 130,8
ICF (7) A 386,6 428,6 472,6 581,6 692,8 760,8 760,8 760,8
MODULO IDRONICO(opzionale) - HYDRONIC KIT(option)
N.ro di pompe standard / No. of standard pumps - 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2
Potenza nominale pompa / Pump nominal power kW 4,00 4,00 4,00 4,00 5,50 5,50 5,50 5,50
Capacità serbatoio / Tank volume dm3 300 300 300 300 500 500 500 500
Prevalenza utile (Allestimento MH) / Available pressure (MH configuration) (1) kPa 148 146 137 135 175 163 146 134
Livello sonoro Lp(A) / Sound level Lp(A) (8) dB(A) 69 69 69 69 71 71 71 71
Diametro connessioni idrauliche / Hydraulic connections diameter (in/out) (9) inch 3" 3" 3" 4" 4" 4" 4" 4"
DIMENSIONI E PESI / DIMENSIONS AND WEIGHTS
Lunghezza / Lenght mm 7.750 7.750 7.750 7.750 5.550 5.550 5.550 5.550
Larghezza / Depth mm 1.200 1.200 1.200 1.200 2.400 2.400 2.400 2.400
Altezza / Height mm 2.400 2.400 2.400 2.400 2.400 2.400 2.400 2.400
Peso (senza modulo idronico) / Weight (without hydronic kit) kg 2.336 2.490 2.650 2.828 3.910 4.050 4.104 4.170
53
AIR CONDITIONINGTECH LINE
Disegni dimensionali / Dimensional drawings
240
0
33501200
MOD. CH R290 FC 1065 - 1070
MOD. CH R290 FC 2100 - 2120 - 2130 - 2135 - 2150 - 2160
1200 5550
240
0
CH R 290 FC VDS 71,9 - 373,3 kW
54
Disegni dimensionali / Dimensional drawings
7750
240
0
1200
MOD. CH R290 FC 2190 - 2200 - 2220 - 2230
MOD. CH R290 FC 2270 - 2290 - 2310 - 2330
24005550
240
0
55
AIR CONDITIONINGTECH LINE CH R 290 FC A 73,3 - 295,4 kW
56
COMMERCIAL LINETECH LINE
CHR 290 FC73,3-295,4 kW
57
AIR CONDITIONINGTECH LINE
CH R 290 FCCH R 290 FCLa più ampia gamma di refrigeratori di liquido (EN14511:2013 e classe
energetica ERP 2015-2017) condensati ad aria per installazione in
esterno per ambienti industriali e di processo
A wide range of air cooled liquid chillers (EN14511:2013 and energy
regulation ERP 2015-2017), air condensed for outdoor installation for
industrial and process enviroments
Bicold Engineering Srl da sempre realizza prodotti nel rispetto dell’ambiente
e del risparmio energetico in sintonia con direttive e normative comunitarie
e ponendo la sua attenzione sui problemi legati all’impatto ambientale
con l’obiettivo di essere in coerenza con quanto stabilito dal protocollo di
Montreal (1987), dal protocollo di Kyoto (1997) e il più recente regolamento
(UE) n.517/2014 del Parlamento e del consiglio Europeo, del 16 aprile
2014, sui gas fluorurati a effetto serra e che abroga il regolamento (CE) n.
842/2006.
La ricerca di nuovi refrigeranti a basso impatto ambientale, la limitazione
all’utilizzo e la tassazione per ragioni ambientali su alcuni refrigeranti
sintetici nei prossimi anni, hanno fatto guadagnare al propano (R290) una
alternativa naturale ai tradizionali gas refrigeranti (CFC-HCFC-HFC), ad alto
coefficiente di GWP (Global Warning Potential)
Il propano (R290), come gas refrigerante, non è penalizzato da restrizioni
o regolamenti che ne limitino l’uso, in questo modo può essere utilizzato
per qualsiasi applicazione nel settore del condizionamento, dei processi
industriali e della refrigerazione (applicazioni in media temperatura).
La progettazione è stata realizzata considerando gli elevati contenuti tecnici
in relazione all’utilizzo del propano R290 e le esigenze del mercato a cui
questo prodotto si riferisce. Il principio di base è la combinazione dell’R290
come refrigerante ecologico e il rispetto dei livelli di efficienza ed affidabilità
più elevati.
Applicazioni
• Refrigerazione (in media temperatura)
• Condizionamento
• Processo industriale
Impianti
• Refrigerazione commerciale (negozi, minimarket e supermarket)
• Refrigerazione industriale (centri logistici del freddo e industria
alimentare)
• Catering (Ristorazione)
• Condizionamento comfort
• Processo industriale
• Applicazioni speciali
Installazione
Le unità sono fornite per il funzionamento all’esterno, vengono equipaggiate
con una robusta carpenteria verniciata con vernice epossidica RAL7035
particolarmente resistente agli agenti atmosferici, che ne consente l’impiego
anche in condizioni ambientali estreme.
73,3 – 295,4 kW
H
Hgrandi collettività
large community
sanità
health
terziario
tertiary
industriale
industrial
CH R 290 FC A 73,3 - 295,4 kW
58
the use of propane R290 and market demands in the relevant sector. The
basic principle lies in the use of the eco-friendly refrigerant R290 combined
with meeting the highest standards in terms of efficiency and reliability.
Applications
• Refrigeration (medium temperature application)
• Air conditioning
• Cooling process
Systems
• Commercial refrigeration (sales outlets, minimarkets and supermarkets)
• Industrial refrigeration (logistic cooling centres and food industry)
• Catering
• Air conditioning comfort
• Process cooling
• Special applications
Installation
The units are supplied for operation outdoors. In the case of outdoor
installation, they are equipped with a rugged framework finished with epoxy
paint RAL7035, particularly resistant to atmospheric agents to enable use
even in extreme environmental conditions.
Bicold Engineering Srl has always manufactured energy efficient and eco-
friendly products, in observance of the European directives and standards,
and paying special attention to issues linked to environmental impact with
the objective of meeting all requirements as specified by the protocol of
Montreal (1987) and the protocol of Kyoto (1997) in terms of environmental
emissions, as well as the most recent regulation (EU) no.517/2014 of
the European Parliament and Council, of 16 April 2014, on fluorinated
greenhouse gases, repealing regulation (EC) no. 842/2006.
The research into new refrigerants with low environmental impact, the
limitation of use and taxation for environmental reasons on a number of
synthetic refrigerants over the next few years have meant that propane
(R290) is a natural alternative to traditional refrigerants (CFC-HCFC-HFC),
with high GWP coefficient (Global Warning Potential)
Propane (R290) has attracted a great deal of interest with respect to
synthetic refrigerants (CFC-HCFC-HFC).
R290 is not subject to constraints or regulations that limit use, and therefore
can be used in Air conditioning, cooling process and refrigeration (medium
temperature application).
The design stage took into account the high technical content in relation to
59
AIR CONDITIONINGTECH LINE
CH R 290 PLUS
(in quanto questo tipo di gas è già presente in natura)
(as this gas is already present in nature)
Refrigerante al 100% rispettoso verso l’ambiente
Refrigerant 100% environmentally friendly
Refrigerante non tossico
Non toxic refrigerantRefrigerante naturale
Natural refrigerant
Refrigerante di facile e globale disponibilità
Globally and easily available refrigerant
Refrigerante con la massima sicurezza ambientaleRefrigerant with guaranteed maximum environmental safety
Refrigerante a basso costo
Low cost refrigerant
Potenziale di distruzione dell’ozono ODP (ozone depleting potential) pari a zero (assenza di CFC all’interno del refrigerante)
Ozone depletion potential (ODP) equal to zero(no CFCs in the refrigerant)
Tasso di riscaldamento globale del pianeta GWP (global warming potential) pari a 3
Global warming potential (GWP) equal to 3
Classe A in funzionamento Raffreddamento (opzionale)
A Class in cooling version (optional)
Basso contenuto di refrigerante
Lower refrigerant charge
Controllo auto adattativo che permette:
1. Limitazione spunti avviamento compressore
2. Tempo minimo di funzionamento del
compressore per il ritorno dell’olio
3. Possibilità di ridurre o eliminare l’uso di un
serbatoio dell’acqua
Adaptive self-control that allows:
1. Limitation compressor starter
2. Minimum run time of the compressor for
oil return
3. Possibility to reduce or eliminate the use
of a water tank
CH R 290 FC A 73,3 - 295,4 kW
60
Nuovo ventilatore ad alta efficienza con pale in tecno polimero per una ridotta emissione sonora
New high efficiency axial fans with blades in high resistance tecnopolymer, with low sound emission
Disponibile con recupero energetico parziale
integrato che consente di recuperare il
calore di condensazione che può consentire
la produzione gratuita di acqua calda a
temperatura massima 50°C per vari utilizzi:
1. Acqua calda sanitaria
2. Batterie ad acqua calda per post-
riscaldamento (centrali trattamento aria e
roof top ecc.)
3. Altri processi o lavorazioni che richiedono
acqua calda
Available with partial integrated energy recovery that allows to recover the heat of condensation in order to produce free hot water at maximum 50°C to use it for:
1. Domestic hot water2. Hot water Batteries post - heating
(air handling units and roof top units etc.)
3. Other processes or processes that require hot water
Estesi limiti di funzionamento
• Temperatura esterna 0°C / +43°C
• Produzione acqua calda +40°C / +45°C
Extended operating limits• Ambient temperature 0°C / +43°C• Hot water production +40°C / +45°C
A richiesta carpenteria
in acciaio INOX
Stainless steel version on demand
Free Cooling è il raffreddamento gratuito di un fluido grazie alla bassa temperatura
dell’ambiente esterno, senza l’attivazione di compressori con un risparmio energetico.
Free Cooling a liquid thanks to low ambient temperature that avoids to switch on the compressors and saves energy
Carpenteria saldata
Welded frame
Applicazioni a bassa temperatura acqua in funzionamento
raffrescamento fino a -5°C
Low water temperature applications in cooling operation down to -5°C
Tubazioni in acciaio inossidabile
Stailess steel piping
Separazione aeraulica tra il circuito refrigerante e il lato condensazione
Aeraulic separation between the refrigerant circuit and the condensation side
Modulazione della capacità dell’impianto ottimizzando il consumo energetico
Modulation system capacity optimizing the energy consumption
61
AIR CONDITIONINGTECH LINE
Identificazione del modello - Identificazione del modello
R290CH FC 2 230 VDS MH
CH MODELLI MODELS
Gruppi refrigeratori di liquido con condensazione ad ARIA con ventilatori assiali (installazione idonea all’esterno), con
compressori semi ermetici ed evaporatori a piastre
Liquid chillers AIR cooled with axial fans (for outdoor installation), with semi hermetic compressors and plates exchanger
REFRIGERANTE REFRIGERANT
Propano R290
Propane R290
FREE COOLING
ALLESTIMENTO CONFIGURATION
HE Unità ad alta efficienza con compressori più piccoli e batterie maggiorate
PHR Unità con recuperatore di calore parziale
IXF Unità con carpenteria in acciaio inox
IXWP Unità con tubazioni acqua in acciaio inox
SPBT Unità con serbatoio in acciaio inox
SDF Unità con carpenteria saldata
SE Unità con solo evaporatore. E’ compreso il pressostato differenziale a protezione dell’evaporatore.
MP Unità con evaporatore e una pompa centrifuga. E’ compreso il pressostato differenziale a protezione dell’evaporatore.
DP Unità con evaporatore e doppia pompa centrifuga. E’ compreso il pressostato differenziale a protezione dell’evaporatore.
MH Unità con modulo idronico; l’allestimento comprende una pompa centrifuga, il serbatoio di accumulo, la valvola di sicurezza acqua tarata a 3 Bar e il pressostato differenziale a protezione dell’evaporatore.
MHD Unità con modulo idronico; l’allestimento comprende la doppia pompa centrifuga, il serbatoio di accumulo, la valvola di sicurezza acqua tarata a 3 Bar e il pressostato differenziale a protezione dell’evaporatore.
HE High efficiency unit with a combination of smaller compressors and bigger condenser
PHR Unit with partial heat recovery (desuperheater)
IXF Unit with inox frame
IXWP Unit with water stainless steel pipes
SPBT Unit with buffer tank
SDF Unit with welded frame
SE Unit with evaporator only. It includes differential pressure switch for evaporator protection
MP Unit with evaporator and one centrifugal pump. It includes differential pressure switch for evaporator protection.
DP Unit with evaporator and double centrifugal pump. It includes differential pressure switch for evaporator protection.
MH Unit with hydronic modul; configuration includes one centrifugal pump, buffer tank, safety water valve (set 3 Bar) and differential pressure switch for evaporator protection.
MHD Unit with hydronic modul; configuration includes double centrifugal pump, buffer tank, safety water valve (set 3 Bar) and differential pressure switch for evaporator protection.
N. CIRCUITI FRIGORIFERI N. REFRIGERANT CIRCUIT
2 due circuiti
2 two circuits
VERSIONE VERSION
VDS di serie - A Classe A
VDS standard - A A class
R290
FC
2
VDS
MH
TAGLIA SIZE
Potenza frigorifera [kW] alle condizioni operative nominali (temperatura acqua refrigerata +12/+7 °C temperatura aria esterna +32 °C)
Cooling capacity [kW] at nominal operating conditions (chilled water temperature +12/+7 °C outdoor air temperature +32 °C)
230
CH R 290 FC A 73,3 - 295,4 kW
62
Garanzia di Qualità e Risparmio Energetico
Quality and Energy Saving Guarantee
63
AIR CONDITIONINGTECH LINE
I modelli denominati CH R290 sono unità solo freddo.
Il fluido frigorigeno utilizzato è l’R290.
L’intera gamma è sostituita da un ampio numero di modelli con
potenza frigorifera da 73,3 a 295,4 kW ed è caratterizzata da
soluzioni attente all’efficienza energetica, alla silenziosità, versatilità e
alla semplicità nell’uso e la manutenzione.
I compressori utilizzati sono del tipo semi ermetico a pistoni progettati
per il funzionamento con il refrigerante R290.
I condensatori sono del tipo a batteria con tubo in rame e alette in
alluminio ad alta efficienza.
I ventilatori impiegati sono del tipo assiale a basso numero di giri
e alta efficienza realizzati in polimero ad alta resistenza, di serie è
presente un controllo di velocità dei ventilatori attraverso un regolatore
di giri a taglio di fase (opzionale elettronico).
Lo scambiatore rigenerativo è a piastre saldobrasate in acciaio
inox AISI 316 ed è termicamente isolato con materiale espanso a
cellule chiuse per una maggior protezione del compressore e per
aumentare le performance del sistema.
L’evaporatore è a piastre saldobrasate in acciaio inox AISI 316 ed è
termicamente isolato con materiale espanso a cellule chiuse.
Il circuito frigorifero include la valvola di espansione con funzione
MOP, filtro deidratatore, indicatore di passaggio e umidità, pressostati
di alta e bassa pressione e valvola di sicurezza.
Il Free Cooling include la batteria ad acqua, la valvola a tre vie On/
Off e la regolazione elettronica. La regolazione dei ventilatori avviene
in funzione della pressione di condensazione quando il compressore
è acceso e in funzione della temperatura dell’acqua quando il Free
Cooling è attivo e il compressore è spento. Durante il funzionamento
misto, con compressore acceso e Free Cooling attivo, i ventilatori
regolano in funzione della pressione di condensazione.
La regolazione dei refrigeratori avviene mediante un controllore
elettronico a microprocessore.
Per tutti i modelli della gamma CH R290 è attiva la funzione di
“unloading per alta pressione”, che permette il funzionamento
dell’unità anche in condizioni ambientali estreme.
Le carpenterie sono costruite in lamiera di acciaio al carbonio zincata
e con verniciatura a forno con polveri epossidiche per assicurare la
migliore resistenza agli agenti atmosferici.
Il colore delle unità è il RAL 7035.
Alcuni componenti possono essere certificati Atex.
CARATTERISTICHE PRINCIPALI
La logica di regolazione dei ventilatori di condensazione per unità Free
Cooling CHR 290 FC prevede tre modalità di funzionamento:
1) Funzionamento “Chiller”: raffreddamento con compressori accesi e
valvola acqua chiusa. La regolazione dei ventilatori avviene in funzione
della pressione di condensazione, la valvola acqua è chiusa (la temperatura
esterna non permette uno scambio termico vantaggioso).
2) Funzionamento “Free Cooling”: raffreddamento con compressori spenti
e valvola acqua aperta. La regolazione dei ventilatori avviene in funzione
della temperatura acqua in uscita dell’unità, la valvola acqua è aperta (la
temperatura esterna permette uno scambio termico vantaggioso).
3) Funzionamento “Free Cooling + Chiller”: detto “combinato”, i
compressori possono essere accesi o spenti e valvola acqua aperta.
La regolazione dei ventilatori avviene in funzione della pressione di
condensazione a compressori accesi, mentre la regolazione dei ventilatori
a compressori spenti avviene in funzione della temperatura acqua in uscita
dell’unità, la valvola acqua è aperta (la temperatura esterna permette uno
scambio termico parzialmente vantaggioso)
REGOLAZIONE VENTILATORI
CH R 290 FC A 73,3 - 295,4 kW
64
Models CH R290 are only cooling units.
These units work with refrigerant R290.
The whole range is composed of several models with cooling capacity
from 73,3 up to 295,4 kW and it is defined by solutions careful to
energy efficiency, soundproof, versatility and easiness of use and
maintenance.
Semi hermetic compressors designed to work with refrigerant R290.
High efficiency condenser coils are made of copper pipes and
aluminium fins.
High efficiency fans are axial type with low RPM made in high
resistance tecnopymer, there is as a standard equipment a fan speed
regulator by a speed cut phase regulator (electronic as option).
The regenerative heat exchanger is stainless steel AISI 316 brazed
plates with thermal insulation of close cells material for compressors
higher protection and to increase the performance of the system.
The evaporator is stainless steel AISI 316 brazed plates with thermal
insulation of close cells material.
Refrigerant circuit includes expansion valve with MOP function, drier
filter, sight glass, high and low pressure switches and safety valve.
Free cooling configuration includes water coil, On/Off three ways
water valve and electronic regulation. Fans regulation is according
on condensing pressure when compressor is on, and according on
water temperature when Free Cooling is activated and compressor is
switched off. During combined operation, with compressor on and Free
Cooling activated, fans speed depends on condensing pressure.
Units are regulated by a microprocessor electronic board.
In all models of CH R290 there is the “high pressure unloading”
function which guarantees the operation of the units even in heavy
weather conditions.
Frames are built in galvanized metal sheet and oven painting with
epoxy powder to ensure resistance to atmospheric agents.
Color is RAL 7035.
Some components can be certified Atex.
MAIN FEATURES
There are 3 modalities for the regulation of condensing fans in CHR 290
FC Free Cooling units:
1) “Chiller” modality: cooling with the compressors switched on and
the water valve closed. The regulation of condensing fans speed occurs
according to the condensing pressure. The water valve is closed (the external
temperature does not allow a favorable heat exchange).
2) “Free Cooling” modality: cooling with the compressors switched off
and the water valve open. The regulation of condensing fans speed occurs
according to the outlet water temperature of the unit. The water valve is
open (the external temperature allows a favorable heat exchange).
3) “Free Cooling + Chiller” modality - said “combined modality”:
the compressors can be switched on or off, the water valve is open. The
regulation of condensing fans speed occurs according to the condensing
pressure, when the compressors are switched on; on the contrary, it occurs
according to the outlet water temperature of the unit, when the compressors
are switched off. The water valve is open ( the external temperature allows a
partially favorable heat exchange).
FANS REGULATION
65
AIR CONDITIONINGTECH LINE
1) Temperatura aria esterna 30°C; temperatura acqua ingresso-uscita evaporatore 15-10°C / In/out evaporator, water 15-10 °C outside air temperature 30°C2) Temperatura aria esterna 5°C; temperatura acqua ingresso evaporatore 15°C / In evaporator, water 15°C outside air temperature 5°C3) Temperatura aria esterna 0°C; temperatura acqua ingresso evaporatore 15°C / In evaporator, water 15°C outside air temperature 0°C4) Prevalenza utile (Allestimento MP) con perdite di carico batteria free cooling, scambiatore a piastre, valvola a tre vie e circuito idraulico/Available pressure (MP configuration) with pressure drop of free
cooling coil, plates evaporator, 3 ways valve and hydraulic circuit 5) FLA = Corrente assorbita a pieno carico. Nella versione Std senza pompa. / Absorbed current at full charge. Standard version without pump.6) FLI = Potenza assorbita a pieno carico. Nella versione Std senza pompa. / Absorbed power at full charge. Standard version without pump.7) ICF = Corrente di spunto alla partenza dell’ultimo compressore. Nella versione std senza pompa/ Max starting current (when last compressor starts) Standard version without pump8) Valore della pressione sonora Lp(A) senza gruppo idronico, a 10 metri dalla macchina, 1 metro di altezza da terra ed in campo libero / Noise pressure value Lp(A) without hydronic group, at 10 mt, at 1
high mt from the ground, in free field conditions 9) Connessioni ODS con attacco femmina a saldare / Welded female connections ODS
MOD. CH R290 FC 1065 1070 2100 2120 2130 2135
PRESTAZIONI / PERFOMANCES (W 15/10°- A 30°)
Potenza frigorifera / Cooling capacity (1) kW 73,3 86,1 116,1 140,7 155,6 172,1
Potenza assorbita compressori / Compressors absorbed power kW 17,8 18,2 24,4 30,1 34,1 36,4
PRESTAZIONI (Free Cooling) / PERFORMANCES (Free Cooling)
Potenza frigorifera / Cooling capacity (W15°; A5°) (2) kW 47,0 94,0 94,0 141,0 141,0 188,0
Potenza frigorifera / Cooling capacity (W15°; A0°) (3) kW 70,5 141,0 141,0 211,5 211,5 282,0
Temperatura Free Cooling totale / Total Free Cooling temperature °C -0,6 5,8 2,6 5,0 4,0 5,8
Perdite di carico batteria FC / Pressure drop FC water coil kPa 30 32 34 33 34 35
Perdita di carico valvola acqua 3 vie / Pressure drop 3 ways water valve kPa 24 22 24 25 23 25
Prevalenza utile (Allestimento MP) / Available pressure (MP configuration) (4) kPa 125 129 111 100 135 121
Numero di ventilatori sezione FC / Number of fans section FC - 1 2 2 3 3 4
Potenza assorbita sezione ventilante FC / Fans absorbed power section FC kW 1,7 3,4 3,4 5,1 5,1 6,8
EVAPORATORE / EVAPORATOR
Tipo / Type - Piastre / Plates
N.ro / No. - 1 1 1 1 1 1
Portata acqua / Water flow (1) m3/h 12,6 14,8 20 24,2 26,8 29,6
Perdita di carico / Pressure drop (1) kPa 44 46 48 46 47 48
Prevalenza utile (Allestimento MP) / Available pressure (MP configuration) (1) kPa 155 161 145 133 169 156
COMPRESSORI / COMPRESSORS
Tipo / type Semi ermetico / Semi hermetic
N.ro / No. - 1 1 2 2 2 2
N.ro compressori / No. compressors
N.ro di circuiti frigoriferi / No. refrigerant circuits-/- 1/1 1/1 2/2 2/2 2/2 2/2
Gradini di parzializzazione / Capacity steps - 2 2 4 4 4 4
CONDENSATORE / CONDENSER
Tipo / Type Batteria alettata / Finned coil
N.ro / No. - 1 1 1 1 1 1
VENTILATORI / FANS
Tipo / Type - Assiali / Axials
N.ro/Diametro / No./Diameter - 2x800 4x800 4x800 6x800 6x800 8x800
Portata aria totale / Total air flow m3/h 42.000 84.000 84.000 126.000 126.000 168.000
CH R 290 FC A 73,3 - 295,4 kW
66
1) Temperatura aria esterna 30°C; temperatura acqua ingresso-uscita evaporatore 15-10°C / In/out evaporator, water 15-10 °C outside air temperature 30°C2) Temperatura aria esterna 5°C; temperatura acqua ingresso evaporatore 15°C / In evaporator, water 15°C outside air temperature 5°C3) Temperatura aria esterna 0°C; temperatura acqua ingresso evaporatore 15°C / In evaporator, water 15°C outside air temperature 0°C4) Prevalenza utile (Allestimento MP) con perdite di carico batteria free cooling, scambiatore a piastre, valvola a tre vie e circuito idraulico/Available pressure (MP configuration) with pressure drop of free
cooling coil, plates evaporator, 3 ways valve and hydraulic circuit 5) FLA = Corrente assorbita a pieno carico. Nella versione Std senza pompa. / Absorbed current at full charge. Standard version without pump.6) FLI = Potenza assorbita a pieno carico. Nella versione Std senza pompa. / Absorbed power at full charge. Standard version without pump.7) ICF = Corrente di spunto alla partenza dell’ultimo compressore. Nella versione std senza pompa/ Max starting current (when last compressor starts) Standard version without pump8) Valore della pressione sonora Lp(A) senza gruppo idronico, a 10 metri dalla macchina, 1 metro di altezza da terra ed in campo libero / Noise pressure value Lp(A) without hydronic group, at 10 mt, at 1
high mt from the ground, in free field conditions 9) Connessioni ODS con attacco femmina a saldare / Welded female connections ODS
MOD. CH R290 FC 1065 1070 2100 2120 2130 2135
DATI ELETTRICI / ELECTRICAL DATA
FLA (5) A 63,2 74,4 104,4 117,6 133,6 148,8
FLI (6) kW 24,1 29,3 36,2 47,2 51,6 58,6
ICF (7) A 252,2 274,4 262,4 272,6 322,6 348,8
MODULO IDRONICO(opzionale) - HYDRONIC KIT(option)
N.ro di pompe standard / No. of standard pumps - 1/2 1/2 1/2 1/2 1/2 1/2
Potenza nominale pompa / Pump nominal power kW 1,50 2,20 2,20 2,20 3,00 3,00
Capacità serbatoio / Tank volume dm3 - - 300 300 300 300
Prevalenza utile (Allestimento MH) / Available pressure (MH configuration) (1) kPa 140 146 130 118 154 141
Livello sonoro Lp(A) / Sound level Lp(A) (8) dB(A) 61 67 67 69 69 70
Diametro connessioni idrauliche / Hydraulic connections diameter (in/out) (9) inch 2" 2" 2 1/2" 2 1/2" 2 1/2" 2 1/2"
DIMENSIONI E PESI / DIMENSIONS AND WEIGHTS
Lunghezza / Lenght mm 3.350 5.550 5.550 7.750 7.750 5.550
Larghezza / Depth mm 1.200 1.200 1.200 1.200 1.200 2.400
Altezza / Height mm 2.400 2.400 2.400 2.400 2.400 2.400
Peso (senza modulo idronico) / Weight (without hydronic kit) kg 888 1.760 1.877 2.241 2.302 3.520
67
AIR CONDITIONINGTECH LINE
1) Temperatura aria esterna 30°C; temperatura acqua ingresso-uscita evaporatore 15-10°C / In/out evaporator, water 15-10 °C outside air temperature 30°C2) Temperatura aria esterna 5°C; temperatura acqua ingresso evaporatore 15°C / In evaporator, water 15°C outside air temperature 5°C3) Temperatura aria esterna 0°C; temperatura acqua ingresso evaporatore 15°C / In evaporator, water 15°C outside air temperature 0°C4) Prevalenza utile (Allestimento MP) con perdite di carico batteria free cooling, scambiatore a piastre, valvola a tre vie e circuito idraulico/Available pressure (MP configuration) with pressure drop of free
cooling coil, plates evaporator, 3 ways valve and hydraulic circuit 5) FLA = Corrente assorbita a pieno carico. Nella versione Std senza pompa. / Absorbed current at full charge. Standard version without pump.6) FLI = Potenza assorbita a pieno carico. Nella versione Std senza pompa. / Absorbed power at full charge. Standard version without pump.7) ICF = Corrente di spunto alla partenza dell’ultimo compressore. Nella versione std senza pompa/ Max starting current (when last compressor starts) Standard version without pump8) Valore della pressione sonora Lp(A) senza gruppo idronico, a 10 metri dalla macchina, 1 metro di altezza da terra ed in campo libero / Noise pressure value Lp(A) without hydronic group, at 10 mt, at 1
high mt from the ground, in free field conditions 9) Connessioni ODS con attacco femmina a saldare / Welded female connections ODS
MOD. CH R290 FC 2150 2160 2190 2200 2220 2230
PRESTAZIONI / PERFOMANCES (W 15/10°- A 30°)
Potenza frigorifera / Cooling capacity (1) kW 188,6 214,5 236,0 257,6 282,4 295,4
Potenza assorbita compressori / Compressors absorbed power kW 40,8 45,4 51,6 55,7 62,4 67,8
PRESTAZIONI (Free Cooling) / PERFORMANCES (Free Cooling)
Potenza frigorifera / Cooling capacity (W15°; A5°) (2) kW 188,0 235,0 235,0 282,0 282,0 282,0
Potenza frigorifera / Cooling capacity (W15°; A0°) (3) kW 282,0 352,5 352,5 423,0 423,0 423,0
Temperatura Free Cooling totale / Total Free Cooling temperature °C 5,0 5,9 5,0 5,9 5,0 4,5
Perdite di carico batteria FC / Pressure drop FC water coil kPa 34 32 36 35 37 38
Perdita di carico valvola acqua 3 vie / Pressure drop 3 ways water valve kPa 22 23 22 24 23 24
Prevalenza utile (Allestimento MP) / Available pressure (MP configuration) (4) kPa 117 132 121 116 161 152
Numero di ventilatori sezione FC / Number of fans section FC - 4 5 5 6 6 6
Potenza assorbita sezione ventilante FC / Fans absorbed power section FC kW 6,8 8,5 8,5 10,2 10,2 10,2
EVAPORATORE / EVAPORATOR
Tipo / Type - Piastre / Plates
N.ro / No. - 1 1 1 1 1 1
Portata acqua / Water flow (1) m3/h 32,4 36,9 40,6 44,3 48,6 50,8
Perdita di carico / Pressure drop (1) kPa 45 47 48 45 47 48
Prevalenza utile (Allestimento MP) / Available pressure (MP configuration) (1) kPa 151 164 157 151 198 190
COMPRESSORI / COMPRESSORS
Tipo / type Semi ermetico / Semi hermetic
N.ro / No. - 2 2 2 2 2 2
N.ro compressori / No. compressors
N.ro di circuiti frigoriferi / No. refrigerant circuits-/- 2/2 2/2 2/2 2/2 2/2 2/2
Gradini di parzializzazione / Capacity steps - 4 4 4 4 4 4
CONDENSATORE / CONDENSER
Tipo / Type Batteria alettata / Finned coil
N.ro / No. - 1 1 1 1 1 1
VENTILATORI / FANS
Tipo / Type - Assiali / Axials
N.ro/Diametro / No./Diameter - 8x800 10x800 10x800 12x800 12x800 12x800
Portata aria totale / Total air flow m3/h 168.000 210.000 210.000 252.000 252.000 252.000
CH R 290 FC A 73,3 - 295,4 kW
68
1) Temperatura aria esterna 30°C; temperatura acqua ingresso-uscita evaporatore 15-10°C / In/out evaporator, water 15-10 °C outside air temperature 30°C2) Temperatura aria esterna 5°C; temperatura acqua ingresso evaporatore 15°C / In evaporator, water 15°C outside air temperature 5°C3) Temperatura aria esterna 0°C; temperatura acqua ingresso evaporatore 15°C / In evaporator, water 15°C outside air temperature 0°C4) Prevalenza utile (Allestimento MP) con perdite di carico batteria free cooling, scambiatore a piastre, valvola a tre vie e circuito idraulico/Available pressure (MP configuration) with pressure drop of free
cooling coil, plates evaporator, 3 ways valve and hydraulic circuit 5) FLA = Corrente assorbita a pieno carico. Nella versione Std senza pompa. / Absorbed current at full charge. Standard version without pump.6) FLI = Potenza assorbita a pieno carico. Nella versione Std senza pompa. / Absorbed power at full charge. Standard version without pump.7) ICF = Corrente di spunto alla partenza dell’ultimo compressore. Nella versione std senza pompa/ Max starting current (when last compressor starts) Standard version without pump8) Valore della pressione sonora Lp(A) senza gruppo idronico, a 10 metri dalla macchina, 1 metro di altezza da terra ed in campo libero / Noise pressure value Lp(A) without hydronic group, at 10 mt, at 1
high mt from the ground, in free field conditions 9) Connessioni ODS con attacco femmina a saldare / Welded female connections ODS
MOD. CH R290 FC 2150 2160 2190 2200 2220 2230
DATI ELETTRICI / ELECTRICAL DATA
FLA (5) A 148,8 168,0 186,0 211,2 229,2 253,2
FLI (6) kW 63,5 72,9 79,7 88,4 95,8 100,9
ICF (7) A 348,8 362,0 401,0 450,2 494,2 603,2
MODULO IDRONICO(opzionale) - HYDRONIC KIT(option)
N.ro di pompe standard / No. of standard pumps - 1/2 1/2 1/2 1/2 1/2 1/2
Potenza nominale pompa / Pump nominal power kW 3,00 4,00 4,00 4,00 5,50 5,50
Capacità serbatoio / Tank volume dm3 300 300 300 300 300 300
Prevalenza utile (Allestimento MH) / Available pressure (MH configuration) (1) kPa 136 149 142 136 183 175
Livello sonoro Lp(A) / Sound level Lp(A) (8) dB(A) 70 71 71 71 71 71
Diametro connessioni idrauliche / Hydraulic connections diameter (in/out) (9) inch 2 1/2" 3" 3" 3" 3" 4"
DIMENSIONI E PESI / DIMENSIONS AND WEIGHTS
Lunghezza / Lenght mm 5.550 6.300 6.300 7.750 7.750 7.750
Larghezza / Depth mm 2.400 2.400 2.400 2.400 2.400 2.400
Altezza / Height mm 2.400 2.400 2.400 2.400 2.400 2.400
Peso (senza modulo idronico) / Weight (without hydronic kit) kg 3.754 3.950 4.010 4.250 4.482 4.604
69
AIR CONDITIONINGTECH LINE
Disegni dimensionali / Dimensional drawings
MOD. CH R290 FC A 1065
MOD. CH R290 FC A 1070 - 2100
1200 5550
240
0
240
0
33501200
CH R 290 FC A 73,3 - 295,4 kW
70
Disegni dimensionali / Dimensional drawings
MOD. CH R290 FC A 2120 - 2130
MOD. CH R290 FC A 2135 - 2150
7750
240
0
1200
24005550
240
0
71
AIR CONDITIONINGTECH LINE
Disegni dimensionali / Dimensional drawings
6300
240
0
2400
MOD. CH R290 FC A 2160 - 2190
CH R 290 FC A 73,3 - 295,4 kW
72
Disegni dimensionali / Dimensional drawings
MOD. CH R290 FC A 2200 - 2220 - 2300
7750
240
0
2400
73
AIR CONDITIONINGTECH LINE CH R 290 / CH R 290 FC
Company
74
Anno di Fondazione BICOLD ENGINEERING SRL
Establishment BICOLD ENGINEERING SRL
Anno di Fondazione BICOLD MAGHREB – Algeria
Establishment BICOLD MAGHREB – Algeria
Produzione di unità condensanti e centrali frigorifere
Production Condensing Units & Compressor Packs
Produzione di chiller ad acqua e pompe di calore
Production Liquid Chillers & Heat Pumps
2003
2008
2004
2010
Bicold Engineering was founded in 2003. From the very first begin-
ning Bicold appears as a new reality of the commercial and industrial
refrigeration industry, presenting its first production of condensing units.
Nowadays Bicold Engineering continues its growth developing a who-
le range of units addressed to the refrigeration market: Condensing
units, Multi compressor packs and Liquid coolers (chiller) only cold,
heat pumps, motocondensing and motoevaporating versions.
L’attività di Bicold Engineering ha inizio nel 2003. Si presenta come
nuova realtà produttiva nel mercato della refrigerazione commerciale
e industriale con una prima produzione di Unità Motocondensanti.
Nel corso degli anni, Bicold Engineering ha sviluppato un’intera
gamma di macchine dedicate al mercato del freddo ed offre, oltre
alle Unità motocondensanti, Centrali frigorifere multicompressore e
Refrigeratori di liquido (chillers) sia in versione solo freddo, pompe di
calore, motocondensanti e motoevaporanti.
74
I nostri numeri/Our numberPlus• Design: innovativo e originale, realizzato al 100% dall’Ufficio
Ricerca & Sviluppo di Bicold Engineering
• Design: innovative and original, 100% realized by Bicold
Engineering Research and Development Technical Dept
• Produzione: 100% realizzata da Bicold Engineering
• Production: 100% realized by Bicold Engineering
• Qualità: il 100% delle unità vengono prodotte da Bicold
Engineering e testate prima della spedizione al Cliente
• Quality: 100% of units produced by Bicold Engineering
are tested before the shipment to the Customer
• Flessibilità: nelle soluzioni tecniche e nei veloci tempi di consegna
• Flexibility: on technical solutions and on fast delivery time
• Servizio cliente: grande attenzione e veloci tempi di gestione delle richieste
• Customer care: best attention and fast management of requests
• Ambiente e risparmio energetico: alta e costante attenzione
all’utilizzo delle migliori tecnologie
• Environment and Energy saving: high and steady
attention in the use of best technologies 5000
Numero addetti
Number of Employees40
Paesi Export
Export Countries30
HVAC Famiglie Prodotti
HVAC Product Family3
Mercati di Applicazioni (condizionamento,
climatizzazione, raffreddamento di processo
e refrigerazione nei settori civile, della grande
collettività, agricolo e industriale)
Market Applications (air conditioning, cooling
process and refrigeration in civil, large commu-
nity, agricoltural and industrial sectors )
4
Prodotti a Listino
Products shown on our price list1600
Famiglie Prodotti Refrigerazione
Refrigeration Product Family3
m2 Area Produttiva
m2 Production Facilities
7575
Bicold Engineering S.r.l.
Via dell’Industria 16/A
35020 Arzergrande (PD) ITALY
+39 049 9720691/4
+39 049 9720587
www.bicold.com