cisco 12404 internet router consolidated switch fabric … · 6 cisco 12404 internet router...

18
Americas Headquarters: Cisco Systems, Inc., 170 West Tasman Drive, San Jose, CA 95134-1706 USA Cisco 12404 Internet Router Consolidated Switch Fabric Replacement Instructions Document Order Number: DOC-78-13614-01, May 30, 2008 Product Number: GSR04-FABRIC= This publication provides instructions for removing and replacing a consolidated switch fabric (CSF) card in the Cisco 12404 Internet Router. Safety Guidelines, page 1 Preventing Electrostatic Discharge Damage, page 4 Powering Down the AC Powered Router, page 5 Powering Down the DC Powered Router, page 6 Removing and Replacing a Consolidated Switch Fabric Card, page 7 Reconnecting to an AC Power Source, page 10 Reconnecting to a DC Power Source, page 13 Obtaining Documentation and Submitting a Service Request, page 17 Safety Guidelines Before you begin the replacement procedure, review the safety guidelines in this section to avoid injuring yourself or damaging the equipment. In addition, before installing, configuring, or maintaining the Cisco 12404 Internet Router, review the safety warnings listed in the document Regulatory Compliance and Safety Information for the Cisco 12000 Gigabit Switch Router Series (Document Number 78-4347-09) that accompanied your router.

Upload: others

Post on 18-Aug-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Cisco 12404 Internet Router Consolidated Switch Fabric … · 6 Cisco 12404 Internet Router Consolidated Switch Fabric Replacement Instructions 78-13614-01 Powering Down the DC Powered

Cisco 12404 Internet Router Consolidated Switch Fabric Replacement Instructions

Document Order Number: DOC-78-13614-01, May 30, 2008

Product Number: GSR04-FABRIC=

This publication provides instructions for removing and replacing a consolidated switch fabric (CSF) card in the Cisco 12404 Internet Router.

• Safety Guidelines, page 1

• Preventing Electrostatic Discharge Damage, page 4

• Powering Down the AC Powered Router, page 5

• Powering Down the DC Powered Router, page 6

• Removing and Replacing a Consolidated Switch Fabric Card, page 7

• Reconnecting to an AC Power Source, page 10

• Reconnecting to a DC Power Source, page 13

• Obtaining Documentation and Submitting a Service Request, page 17

Safety GuidelinesBefore you begin the replacement procedure, review the safety guidelines in this section to avoid injuring yourself or damaging the equipment.

In addition, before installing, configuring, or maintaining the Cisco 12404 Internet Router, review the safety warnings listed in the document Regulatory Compliance and Safety Information for the Cisco 12000 Gigabit Switch Router Series (Document Number 78-4347-09) that accompanied your router.

Americas Headquarters:Cisco Systems, Inc., 170 West Tasman Drive, San Jose, CA 95134-1706 USA

Page 2: Cisco 12404 Internet Router Consolidated Switch Fabric … · 6 Cisco 12404 Internet Router Consolidated Switch Fabric Replacement Instructions 78-13614-01 Powering Down the DC Powered

Safety Guidelines

Safety WarningsSafety warnings appear throughout this publication in procedures that, if performed incorrectly, may harm you. A warning symbol precedes each warning statement. The following paragraph is an example of a safety warning. It identifies the warning symbol and associates it with a bodily injury hazard. The remaining paragraphs in this section are translations of the initial safety warning.

Warning This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. (To see translations of the warnings that appear in this publication, refer to the appendix “Translated Safety Warnings” in the installation guide that accompanied this device.)

Waarschuwing Dit waarschuwingssymbool betekent gevaar. U verkeert in een situatie die lichamelijk letsel kan veroorzaken. Voordat u aan enige apparatuur gaat werken, dient u zich bewust te zijn van de bij elektrische schakelingen betrokken risico’s en dient u op de hoogte te zijn van standaard maatregelen om ongelukken te voorkomen. (Voor vertalingen van de waarschuwingen die in deze publicatie verschijnen, kunt u het aanhangsel “Translated Safety Warnings” (Vertalingen van veiligheidsvoorschriften) in de installatiegids die bij dit toestel is ingesloten, raadplegen.

Varoitus Tämä varoitusmerkki merkitsee vaaraa. Olet tilanteessa, joka voi johtaa ruumiinvammaan. Ennen kuin työskentelet minkään laitteiston parissa, ota selvää sähkökytkentöihin liittyvistä vaaroista ja tavanomaisista onnettomuuksien ehkäisykeinoista. (Tässä julkaisussa esiintyvien varoitusten käännökset löydät tämän laitteen mukana olevan asennusoppaan liitteestä "Translated Safety Warnings" (käännetyt turvallisuutta koskevat varoitukset).)

Attention Ce symbole d’avertissement indique un danger. Vous vous trouvez dans une situation pouvant entraîner des blessures. Avant d’accéder à cet équipement, soyez conscient des dangers posés par les circuits électriques et familiarisez-vous avec les procédures courantes de prévention des accidents. Pour obtenir les traductions des mises en garde figurant dans cette publication, veuillez consulter l’annexe intitulée « Translated Safety Warnings » (Traduction des avis de sécurité) dans le guide d’installation qui accompagne cet appareil.

Warnung Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu einer Körperverletzung führen könnte. Bevor Sie mit der Arbeit an irgendeinem Gerät beginnen, seien Sie sich der mit elektrischen Stromkreisen verbundenen Gefahren und der Standardpraktiken zur Vermeidung von Unfällen bewußt. (Übersetzungen der in dieser Veröffentlichung enthaltenen Warnhinweise finden Sie im Anhang mit dem Titel “Translated Safety Warnings” (Übersetzung der Warnhinweise) in der diesem Gerät beiliegenden Installationsanleitung.)

Avvertenza Questo simbolo di avvertenza indica un pericolo. Si è in una situazione che può causare infortuni. Prima di lavorare su qualsiasi apparecchiatura, occorre conoscere i pericoli relativi ai circuiti elettrici ed essere al corrente delle pratiche standard per la prevenzione di incidenti. La traduzione delle avvertenze riportate in questa pubblicazione si trova nell’appendice, “Translated Safety Warnings” (Traduzione delle avvertenze di sicurezza), del manuale d’installazione che accompagna questo dispositivo.

2Cisco 12404 Internet Router Consolidated Switch Fabric Replacement Instructions

78-13614-01

Page 3: Cisco 12404 Internet Router Consolidated Switch Fabric … · 6 Cisco 12404 Internet Router Consolidated Switch Fabric Replacement Instructions 78-13614-01 Powering Down the DC Powered

Safety Guidelines

Safety with EquipmentThe following guidelines will help ensure your safety and protect the equipment. This list is not inclusive of all potentially hazardous situations, so be alert.

• Always disconnect all power cords and interface cables before moving the system.

• Never assume that power is disconnected from a circuit; always check.

• Keep tools and assembly components away from walk areas.

• Do not work alone if potentially hazardous conditions exist.

• Do not perform any action that creates a potential hazard to people or makes the equipment unsafe.

• Carefully examine your work area for possible hazards such as moist floors, ungrounded power extension cables, and missing safety grounds.

Advarsel Dette varselsymbolet betyr fare. Du befinner deg i en situasjon som kan føre til personskade. Før du utfører arbeid på utstyr, må du være oppmerksom på de faremomentene som elektriske kretser innebærer, samt gjøre deg kjent med vanlig praksis når det gjelder å unngå ulykker. (Hvis du vil se oversettelser av de advarslene som finnes i denne publikasjonen, kan du se i vedlegget "Translated Safety Warnings" [Oversatte sikkerhetsadvarsler] i installasjonsveiledningen som ble levert med denne enheten.)

Aviso Este símbolo de aviso indica perigo. Encontra-se numa situação que lhe poderá causar danos fisicos. Antes de começar a trabalhar com qualquer equipamento, familiarize-se com os perigos relacionados com circuitos eléctricos, e com quaisquer práticas comuns que possam prevenir possíveis acidentes. (Para ver as traduções dos avisos que constam desta publicação, consulte o apêndice “Translated Safety Warnings” - “Traduções dos Avisos de Segurança”, no guia de instalação que acompanha este dispositivo).

¡Advertencia! Este símbolo de aviso significa peligro. Existe riesgo para su integridad física. Antes de manipular cualquier equipo, considerar los riesgos que entraña la corriente eléctrica y familiarizarse con los procedimientos estándar de prevención de accidentes. (Para ver traducciones de las advertencias que aparecen en esta publicación, consultar el apéndice titulado “Translated Safety Warnings,” en la guía de instalación que se acompaña con este dispositivo.)

Varning! Denna varningssymbol signalerar fara. Du befinner dig i en situation som kan leda till personskada. Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och känna till vanligt förfarande för att förebygga skador. (Se förklaringar av de varningar som förekommer i denna publikation i appendix "Translated Safety Warnings" [Översatta säkerhetsvarningar] i den installationshandbok som medföljer denna anordning.)

3Cisco 12404 Internet Router Consolidated Switch Fabric Replacement Instructions

78-13614-01

Page 4: Cisco 12404 Internet Router Consolidated Switch Fabric … · 6 Cisco 12404 Internet Router Consolidated Switch Fabric Replacement Instructions 78-13614-01 Powering Down the DC Powered

Preventing Electrostatic Discharge Damage

Safety with ElectricityFollow these basic guidelines when working with any electrical equipment:

• Before beginning any procedures requiring access to the interior of the router, locate the emergency power-off switch for the room in which you are working.

• Disconnect all power and external cables before installing or removing a router.

• Never assume that power has been disconnected from a circuit; always check.

• Do not perform any action that creates a potential hazard to people or makes the equipment unsafe.

• Never install equipment that appears damaged.

• Carefully examine your work area for possible hazards such as moist floors, ungrounded power extension cables, and missing safety grounds.

• If an electrical accident does occur, proceed as follows:

– Use caution; do not become a victim yourself. Disconnect power to the router.

– If possible, send another person to get medical aid; otherwise, assess the condition of the victim and then call for help.

– Determine if the person needs rescue breathing or external cardiac compressions; then take appropriate action.

In addition, observe the following guidelines when working with any equipment that is disconnected from a power source but still connected to telephone or network wiring:

• Never install telephone wiring during a lightning storm.

• Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations.

• Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface.

Use caution when installing or modifying telephone lines.

Preventing Electrostatic Discharge DamageElectrostatic discharge (ESD) damage to circuit boards can occur if they are handled improperly. Such mishandling can result in intermittent or complete failures of the board.

When handling circuit boards, observe the following guidelines to prevent ESD damage.

• Always use an ESD-preventive ankle or wrist strap and ensure that the strap makes adequate contact with your skin.

• Attach an ESD-preventive strap to your wrist or ankle and to the chassis; or to a bare metal surface. See Figure 1.

• The ankle or wrist strap protects equipment from ESD voltages on the body only; ESD voltages on clothing can still cause damage to electronic components.

4Cisco 12404 Internet Router Consolidated Switch Fabric Replacement Instructions

78-13614-01

Page 5: Cisco 12404 Internet Router Consolidated Switch Fabric … · 6 Cisco 12404 Internet Router Consolidated Switch Fabric Replacement Instructions 78-13614-01 Powering Down the DC Powered

Powering Down the AC Powered Router

Figure 1 Attach ESD-Preventive Strap to Cisco 12404 Internet Router Chassis

Caution Periodically check the resistance value of the antistatic ankle or wrist strap. The resistance measurement should be between 1 and 10 megohms.

Powering Down the AC Powered RouterPowering down the AC powered router is presented in the following steps:

Step 1 Turn the AC PEM power switch off for each AC PEM.

Step 2 Turn off all circuit breakers for the AC source power.

Step 3 Unplug all power cords from all AC power source outlets.

Step 4 Attach an ESD-preventive strap to your wrist or ankle. Attach the ESD clip to the chassis or to a bare metal surface.

CONSOLIDATED SWITCH FABRIC

CRITICALMAJOR

MINOR

MBUS

FAILENABLE

ALARM FABRIC

10

23

40C48/POS-SR-SC

TX

RX

ACTIVE

CARRIER

RX PKT

CLASS 1 LASER PRODUCTLASERPRODUKT DER KLASSE 1PRODUIT LASER DE CLASSE 1PRODUCTO LASER DE CLASSE 1

CLEANCONNECTORWITH ALCOHOLWIPES BEFORECONNECTING

SLOT-0

GIGABIT ROUTE PROCESSOR

SLOT-1

COLL

LINK

TX

RX

RJ-45

MII

RESET

AUX

EJECT

CONSOLE

6627

3

5Cisco 12404 Internet Router Consolidated Switch Fabric Replacement Instructions

78-13614-01

Page 6: Cisco 12404 Internet Router Consolidated Switch Fabric … · 6 Cisco 12404 Internet Router Consolidated Switch Fabric Replacement Instructions 78-13614-01 Powering Down the DC Powered

Powering Down the DC Powered Router

Figure 2 AC PEM

Step 5 Release the bail latch holding the AC power cord to the power receptacle.

Step 6 Unplug the power cord from the AC PEM receptacle.

Step 7 Verify that the green AC PEM INPUT OK, OUTPUT OK and amber OUTPUT FAIL LEDs are all off.

Step 8 Visually check that the AC PEM fans are all off.

Step 9 Visually check that the fan tray assembly fans are all off.

Step 10 Visually check that all route processor (RP) and line card LEDs are all off.

Step 11 Visually check that the CSF LEDs are all off.

Caution In a noisy environment, place your hand in front of the fan compartment on each part with a fan, to ensure the fans are all off.

Powering Down the DC Powered RouterPowering down the DC powered router is presented in the following steps:

Step 1 Turn the DC PEM power switch off for each DC PEM installed.

Step 2 Turn off all circuit breakers for DC source power.

Step 3 Attach an ESD-preventive strap to your wrist or ankle; and attach the ESD clip to the chassis or to a bare metal surface.

Step 4 Verify that the green DC PEM INPUT OK, OUTPUT OK and amber OUTPUT FAIL LEDs are all off.

Step 5 Visually check that the fan tray assembly fans are all off.

Step 6 Visually check that the DC PEM fans are all off.

1 AC PEM handle 4 Power cord receptacle

2 On/Off switch 5 LEDs

3 Bail Latch 6 Captive screws

INPUTOK OUTPUT

FAIL

INPUT100-240V12A50/80HZ

OUTPUTOK

6628

9

456

1 2 3

6Cisco 12404 Internet Router Consolidated Switch Fabric Replacement Instructions

78-13614-01

Page 7: Cisco 12404 Internet Router Consolidated Switch Fabric … · 6 Cisco 12404 Internet Router Consolidated Switch Fabric Replacement Instructions 78-13614-01 Powering Down the DC Powered

Removing and Replacing a Consolidated Switch Fabric Card

Figure 3 DC PEM and PDU

Step 7 Visually check that all RP and line card LEDs are all off.

Step 8 Visually check that the CSF LEDs are all off.

Caution In a noisy environment, place your hand in front of the fan compartment on each part with a fan, to ensure the fans are all off.

Step 9 Remove all power lines positive (+), negative (-) and ground wires connected to the DC PDU block.

Removing and Replacing a Consolidated Switch Fabric CardRemoving and replacing a CSF card instructions are presented in this section. The CSF card occupies the bottom slot in the card cage. See Figure 4.

The CSF occupies the bottom slot in the cage. The CSF card is not hot swappable you cannot remove and replace a CSF card while the system remains powered up.

Caution The CSF card is not hot-swappable component of the Cisco 12404 Internet Router.

1 DC PDU 5 On/Off switch

2 DC PEM 6 PDU captive screws

3 PEM captive screws 7 Terminal Block

4 LEDs

INPUT– 48/60V35A

6629

5

INPUTOK OUTPUT

FAIL

OUTPUTOK

56

43

7

1 2 3

7Cisco 12404 Internet Router Consolidated Switch Fabric Replacement Instructions

78-13614-01

Page 8: Cisco 12404 Internet Router Consolidated Switch Fabric … · 6 Cisco 12404 Internet Router Consolidated Switch Fabric Replacement Instructions 78-13614-01 Powering Down the DC Powered

Removing and Replacing a Consolidated Switch Fabric Card

Figure 4 CSF Slot Location

Tools and EquipmentYou will need the following items to remove and replace a CSF card:

• ESD-preventive strap

• 3/16-inch flat-blade screwdriver

• Antistatic bag (or similar ESD-preventive container)

• CSF GSR04-FABRIC=

Removing a Consolidated Switch Fabric Card To remove a CSF from the card cage follow these steps.

Step 1 Attach an ESD-preventive strap to your wrist or ankle; and attach the ESD clip to the chassis or to a bare metal surface. See the “Preventing Electrostatic Discharge Damage” section on page 4.

Step 2 Power down your router.

• Use the AC power down procedure “Powering Down the AC Powered Router, page 5” for AC powered routers.

• Use the DC power down procedure “Powering Down the DC Powered Router, page 6” for DC powered routers.

Step 3 After you have powered down your router re-attach an ESD-preventive strap to your wrist or ankle; attach the ESD clip to the chassis or to a bare metal surface.

Step 4 Loosen the two captive screws on each side of the CSF card.

Step 5 Grasp the card ejector levers and pivot them away from the CSF card faceplate.

6625

2

0

1

2

3

Fabric Alarm

8Cisco 12404 Internet Router Consolidated Switch Fabric Replacement Instructions

78-13614-01

Page 9: Cisco 12404 Internet Router Consolidated Switch Fabric … · 6 Cisco 12404 Internet Router Consolidated Switch Fabric Replacement Instructions 78-13614-01 Powering Down the DC Powered

Removing and Replacing a Consolidated Switch Fabric Card

Figure 5 Install a CSF Card

Step 6 Slide the CSF half way out of the slot, then stop.

Step 7 Touching only the metal card carrier, use your free hand to support the bottom of the CSF.

Step 8 Slide the card out of the slot and place it directly into an antistatic bag or other ESD-preventive container.

Step 9 If you plan to return the defective CSF to the factory, repackage it in the shipping container you received with the replacement card.

Installing a Consolidated Switch Fabric Card To replace or install a CSF in the line card and CSF cage see Figure 5 and follow these steps:

Step 1 Attach an ESD-preventive strap to your wrist and to the chassis; or to a bare metal surface.

Step 2 Power down your router.

• Use the AC power down procedure “Powering Down the AC Powered Router, page 5” for AC powered routers.

• Use the DC power down procedure “Powering Down the DC Powered Router, page 6 for DC powered routers.

Step 3 After you have powered down your router re-attach an ESD-preventive strap to your wrist or ankle; attach the ESD clip to the chassis or to a bare metal surface and proceed to step 4.

Step 4 Remove the CSF card from its antistatic bag or ESD-preventive container.

• Touching only the metal card carrier.

Note There are card slot alignment grooves on each side of the CSF cage. When you reinstall a card in an CSF slot, make sure you carefully align both edges of the card carrier in the corresponding card slot grooves.

Caution Avoid touching the card circuitry or any connectors.

Step 5 Set both edges of the CSF carrier into the card slot carrier alignment grooves on either side of the CSF cage.

Step 6 Pivot the ejector levers away from each other; rotate each ejector lever outward away from the faceplate.

6629

3

CONSOLIDATED SWITCH FABRIC

CRITICALMAJOR

MINOR

MBUS

FAILENABLE

ALARM FABRIC

10

23

40C48/POS-SR-SC

TX

RX

ACTIVE

CARRIER

RX PKT

CLASS 1 LASER PRODUCTLASERPRODUKT DER KLASSE 1PRODUIT LASER DE CLASSE 1PRODUCTO LASER DE CLASSE 1

CLEANCONNECTORWITH ALCOHOLWIPES BEFORECONNECTING

SLOT-0

GIGABIT ROUTE PROCESSOR

SLOT-1

COLL

LINK

TX

RX

RJ-45

MII

RESET

AUX

EJECT

CONSOLE

9Cisco 12404 Internet Router Consolidated Switch Fabric Replacement Instructions

78-13614-01

Page 10: Cisco 12404 Internet Router Consolidated Switch Fabric … · 6 Cisco 12404 Internet Router Consolidated Switch Fabric Replacement Instructions 78-13614-01 Powering Down the DC Powered

Reconnecting to an AC Power Source

Step 7 Use both thumbs to slide the card carrier into the CSC slot until the ejector levers make contact with the front of the card cage, then stop.

Step 8 Pivot the ejector levers toward the faceplate until the connector seats in the backplane.

Caution CSF ejector levers may not fit flush against the CSF faceplate.

Step 9 Tighten the captive screws on each side of the CSF faceplate.

Step 10 Reconnect the router power source. Depending on which router you ordered, refer to the “Reconnecting to an AC Power Source” section or “Reconnecting to a DC Power Source” section on page 13.

Reconnecting to an AC Power SourceThis section provides the procedure for reconnecting your router to an AC power source.

Caution Turn the AC PEM power switch to the off position before beginning this procedure.

Step 1 Attach an ESD-preventive strap to yourself and to either the chassis, or to a bare metal surface. See the “Preventing Electrostatic Discharge Damage” section on page 4.

Step 2 Locate the AC power cord you removed when you powered down the router.

Step 3 Plug the AC power cord into the AC PEM.

Step 4 Connect the other end of the AC power cord to the AC power source outlet.

Step 5 Verify that the AC power source circuit breaker servicing the AC PEM is switched on.

Step 6 Turn on the AC power switch.

Figure 6 AC PEM LEDs

INPUTOK OUTPUT

FAIL

INPUT100-240V12A50/80HZ

OUTPUTOK

6629

0

INPUTOK

OUTPUTFAIL

OUTPUTOK

1 2 3

10Cisco 12404 Internet Router Consolidated Switch Fabric Replacement Instructions

78-13614-01

Page 11: Cisco 12404 Internet Router Consolidated Switch Fabric … · 6 Cisco 12404 Internet Router Consolidated Switch Fabric Replacement Instructions 78-13614-01 Powering Down the DC Powered

Reconnecting to an AC Power Source

Note When operating your router on an AC power source, both PEM bays must have all AC PEMs installed to ensure compliance with regulatory EMI standards.

Checking the Startup

Check the startup banner and displays to ensure that the system has restarted properly and that all the interfaces reinitialize properly. You should observe the power module LEDs shown in Figure 6. Also, listen for the fans in the fan tray, you should immediately hear them operating. In a noisy environment, the fans might be difficult to hear; therefore, place your hand in front of the exhaust vents at the side of the chassis to verify that the fans are operating.

Visually check the CSF LEDs, MBus LEDs on the CSF, and the RP LEDs on the RP. RP LEDs are located at one end of the RP faceplate, near the ejector lever.

Figure 7 CSF LEDs

Table 1 CSF LEDs

Table 2 CSF MBus Alarm LEDs

1 INPUT OK Green AC is present and within specified limits

2OUTPUT OK Green Power supply module is operating normally in

a powered up condition

3OUTPUT FAIL Amber Power module is operating in a fault condition

and shutdown has occurred

CONSOLIDATED SWITCH FABRIC

CRITICALMAJOR

MINOR MBUS

FAIL

ENABLE

ALARM FABRIC

6624

6CRITICAL

MAJORMINOR

MBUS

FAIL

ENABLE

ALARM FABRIC

Switch Fabric LEDs Status Condition

CRITICAL Off Normally Off

MAJOR Off Normally Off

MINOR Off Normally Off

MBus Alarm LEDs Status Condition

11Cisco 12404 Internet Router Consolidated Switch Fabric Replacement Instructions

78-13614-01

Page 12: Cisco 12404 Internet Router Consolidated Switch Fabric … · 6 Cisco 12404 Internet Router Consolidated Switch Fabric Replacement Instructions 78-13614-01 Powering Down the DC Powered

Reconnecting to an AC Power Source

Table 3 CSF MBus LEDs

On the console terminal, verify that the console displays the system banner and that the system and all interfaces initialize successfully.

If the power supplies do not power up, or if the system or any interfaces do not initialize properly, see Chapter 4, “Troubleshooting the Installation,” in the Cisco 12404 Internet Router Installation and Configuration Guide. If you are still unable to resolve the problem, contact your Cisco service representative for assistance.

FAIL Off Normally Off

ENABLE ON Normally On

MBus Fabric LEDs Status Condition

FAIL Off Normally Off

ENABLE ON Normally On

12Cisco 12404 Internet Router Consolidated Switch Fabric Replacement Instructions

78-13614-01

Page 13: Cisco 12404 Internet Router Consolidated Switch Fabric … · 6 Cisco 12404 Internet Router Consolidated Switch Fabric Replacement Instructions 78-13614-01 Powering Down the DC Powered

Reconnecting to a DC Power Source

Reconnecting to a DC Power SourceThis section provides the procedure for reconnecting your router to a DC power source.

Note We recommend each DC PDU be connected to an independent power source for full redundancy. We also recommend that you use an uninterruptable power source (UPS) to protect against power failures at your site.

Figure 8 DC Power PEM and PDU Assembly

Reconnecting a DC PDU and DC PEM AssemblyEach DC PDU should be connected to separate DC sources using six threaded terminals. Two terminals for negative (source DC), two terminals for positive (source DC return), and two terminals for ground.

Warning Power to your router must be Off and all cables disconnected before you reconnect the DC PDU and DC PEM. The DC PDU and DC PEM when connected, is not a hot-swappable, field replaceable unit.

Use this procedure to reconnect power to the DC PEM and DC PDU. The DC power module housing is located at the rear of the chassis.

Step 1 Attach an ESD-preventive strap to yourself and to either the chassis, or to a bare metal surface. See the “Preventing Electrostatic Discharge Damage” section on page 4.

1 DC PDU 5 On/Off switch

2 DC (PEM) 6 PEM to PDU captive screws

3 System captive screw 7 Terminal Block

4 LEDs

INPUT– 48/60V35A

6629

5

INPUTOK OUTPUT

FAIL

OUTPUTOK

56

43

7

1 2 3

13Cisco 12404 Internet Router Consolidated Switch Fabric Replacement Instructions

78-13614-01

Page 14: Cisco 12404 Internet Router Consolidated Switch Fabric … · 6 Cisco 12404 Internet Router Consolidated Switch Fabric Replacement Instructions 78-13614-01 Powering Down the DC Powered

Reconnecting to a DC Power Source

Figure 9 DC Powered Cisco 12404 Internet Router Rear View

Figure 10 DC PDU Power Block

Step 2 Secure each lead to the proper terminal port by tightening the terminal port connector screws with a 3/16-inch flat-blade screw driver.

Step 3 Verify that the DC power source circuit breaker servicing the DC PEM is switched on.

Checking the Startup

Check the startup banner and displays to ensure that the system has restarted properly and that all the interfaces reinitialize properly. You should observe the power module LEDs shown in Figure 13. Also, listen for the fans in the fan tray, you should immediately hear them operating. In a noisy environment, the fans might be difficult to hear; therefore, place your hand in front of the exhaust vents at the side of the chassis to verify that the fans are operating.

Visually check the CSF LEDs, MBus LEDs on the CSF, and the RP LEDs on the RP. RP LEDs are located at one end of the RP faceplate, near the ejector lever. Figure 12 shows the RP LED displays.

6628

8

INPUT– 48/60V35A

INPUTOK OUTPUT

FAIL

OUTPUTOK

INPUT– 48/60V35A

INPUTOK OUTPUT

FAIL

OUTPUTOK

1 Negative Terminal Port 3 Ground Terminal Port

2 Positive Terminal Port 4 Terminal Port Connector Screws

6694

9

+GND

14

2

3

14Cisco 12404 Internet Router Consolidated Switch Fabric Replacement Instructions

78-13614-01

Page 15: Cisco 12404 Internet Router Consolidated Switch Fabric … · 6 Cisco 12404 Internet Router Consolidated Switch Fabric Replacement Instructions 78-13614-01 Powering Down the DC Powered

Reconnecting to a DC Power Source

Figure 11 CSF LEDs

Table 4 CSF LEDs

Table 5 CSF MBus Alarm LEDs

Table 6 CSF MBus LEDs

On the console terminal, verify that the console displays the system banner and that the system and all interfaces initialize successfully.

CONSOLIDATED SWITCH FABRIC

CRITICALMAJOR

MINOR MBUS

FAIL

ENABLE

ALARM FABRIC

6624

6

CRITICALMAJOR

MINOR

MBUS

FAIL

ENABLE

ALARM FABRIC

Switch Fabric LEDs Status Condition

CRITICAL Off Normally Off

MAJOR Off Normally Off

MINOR Off Normally Off

MBus Alarm LEDs Status Condition

FAIL Off Normally Off

ENABLE ON Normally On

MBus Fabric LEDs Status Condition

FAIL Off Normally Off

ENABLE ON Normally On

15Cisco 12404 Internet Router Consolidated Switch Fabric Replacement Instructions

78-13614-01

Page 16: Cisco 12404 Internet Router Consolidated Switch Fabric … · 6 Cisco 12404 Internet Router Consolidated Switch Fabric Replacement Instructions 78-13614-01 Powering Down the DC Powered

Reconnecting to a DC Power Source

RP Alphanumeric LED Display

RP LEDs are located at one end of the RP faceplate, near the ejector lever. Figure 12 shows the RP alphanumeric LED displays.

Figure 12 RP Alphanumeric LED Displays

Each four-digit display shows part of a two-line system message. During the RP boot process, the LED displays present a sequence of messages similar to that shown in.

Table 7 RP LED Display, Definition, and Source

Right alphanumericLED display (four digits)

Left alphanumericLED display (four digits)

5707

9

LED Display Definition Source

MROMnnnn

The MBus microcode begins to execute; nnnn is the microcode version number. For example, microcode version 1.17 displays as 0117.1

Note This display might not be visible because it occurs for only a brief time.

1. The version of MBus microcode running on your system might be different.

MBus controller

LMEMTEST

Low memory on the RP is being tested. RP ROM monitor

MEMINIT

The size of main memory on the RP is being discovered.

RP ROM monitor

RPRDY

The system is operational and ready to execute basic Cisco IOS software commands at the ROM monitor prompt (rommon>).

RP ROM monitor

RPUP

A valid Cisco IOS image is running. RP IOS software

PRIRP

The RP is enabled and recognized as the system primary. A valid Cisco IOS image is running.

RP IOS software

SECRP

The RP is enabled and recognized as the system secondary. A valid Cisco IOS image is running.

RP IOS software

16Cisco 12404 Internet Router Consolidated Switch Fabric Replacement Instructions

78-13614-01

Page 17: Cisco 12404 Internet Router Consolidated Switch Fabric … · 6 Cisco 12404 Internet Router Consolidated Switch Fabric Replacement Instructions 78-13614-01 Powering Down the DC Powered

Reconnecting to a DC Power Source

DC Power Entry Module LEDs

Verify the DC PEM LEDs are on and their status is OK.

Figure 13 DC PEM LEDs

If the power assembly does not power up, or if the system or any interfaces do not initialize properly, see Chapter 1, “Troubleshooting the Installation.”. If you are still unable to resolve the problem, contact your Cisco service representative for assistance.

Obtaining Documentation and Submitting a Service RequestFor information on obtaining documentation, submitting a service request, and gathering additional information, see the monthly What’s New in Cisco Product Documentation, which also lists all new and revised Cisco technical documentation, at:

http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.html

Subscribe to the What’s New in Cisco Product Documentation as a Really Simple Syndication (RSS) feed and set content to be delivered directly to your desktop using a reader application. The RSS feeds are a free service and Cisco currently supports RSS version 2.0.

1 DC PDU n/a n/a

2 DC PEM n/a n/a

3INPUT OK Green DC is present and within

specified limits

4

OUTPUT OK Green Power supply module is operating normally in a powered up condition

5

OUTPUT FAIL Amber Power module is operating in a fault condition and shutdown has occurred

INPUT– 48/60V35A

6639

9

INPUTOK OUTPUT

FAIL

OUTPUTOK

INPUTOK

OUTPUTFAIL

OUTPUTOK

3

1 2

4 5

17Cisco 12404 Internet Router Consolidated Switch Fabric Replacement Instructions

78-13614-01

Page 18: Cisco 12404 Internet Router Consolidated Switch Fabric … · 6 Cisco 12404 Internet Router Consolidated Switch Fabric Replacement Instructions 78-13614-01 Powering Down the DC Powered

Reconnecting to a DC Power Source

This document is to be used in conjunction with the Cisco 12404 Internet Router Installation and Configuration Guide, Part Number: DOC-7813511=.

CCDE, CCENT, Cisco Eos, Cisco Lumin, Cisco Nexus, Cisco StadiumVision, the Cisco logo, DCE, and Welcome to the Human Network are trademarks; Changing the Way We Work, Live, Play, and Learn is a service mark; and Access Registrar, Aironet, AsyncOS, Bringing the Meeting To You, Catalyst, CCDA, CCDP, CCIE, CCIP, CCNA, CCNP, CCSP, CCVP, Cisco, the Cisco Certified Internetwork Expert logo, Cisco IOS, Cisco Press, Cisco Systems, Cisco Systems Capital, the Cisco Systems logo, Cisco Unity, Collaboration Without Limitation, EtherFast, EtherSwitch, Event Center, Fast Step, Follow Me Browsing, FormShare, GigaDrive, HomeLink, Internet Quotient, IOS, iPhone, iQ Expertise, the iQ logo, iQ Net Readiness Scorecard, iQuick Study, IronPort, the IronPort logo, LightStream, Linksys, MediaTone, MeetingPlace, MGX, Networkers, Networking Academy, Network Registrar, PCNow, PIX, PowerPanels, ProConnect, ScriptShare, SenderBase, SMARTnet, Spectrum Expert, StackWise, The Fastest Way to Increase Your Internet Quotient, TransPath, WebEx, and the WebEx logo are registered trademarks of Cisco Systems, Inc. and/or its affiliates in the United States and certain other countries.

All other trademarks mentioned in this document or Website are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (0805R)

Copyright © 2008, Cisco Systems, Inc..All rights reserved.

18Cisco 12404 Internet Router Consolidated Switch Fabric Replacement Instructions

78-13614-01