CITY OF COLUMBUS ODOR CONTROL PROGRAM OWEA Collection Systems Workshop May 18, 2018

Upload: others

Post on 05-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CITY OF COLUMBUS ODOR CONTROL PROGRAM• Repaired diffuser pipes • Washed inorganic media and reused • Installed locally sourced, organic media • Increased Air Flow to 12,000

CITY OF COLUMBUS ODOR CONTROL PROGRAM

OWEA Collection Systems WorkshopMay 18, 2018

Page 2: CITY OF COLUMBUS ODOR CONTROL PROGRAM• Repaired diffuser pipes • Washed inorganic media and reused • Installed locally sourced, organic media • Increased Air Flow to 12,000

OVERVIEW• Need for odor control• Current and Planned Odor Control Facilities• Design Standards

Presenter
Presentation Notes
Jeremy
Page 3: CITY OF COLUMBUS ODOR CONTROL PROGRAM• Repaired diffuser pipes • Washed inorganic media and reused • Installed locally sourced, organic media • Increased Air Flow to 12,000

NEED FOR ODOR CONTROL• Combined Sewers

– Storm Inlets– Traps– Regulators

• Sanitary Sewers– Drop Manholes– Force Mains

• CSO and SSO Tunnels– drop shafts– relief structures

Water falling to tunnel floor

Odor (H2S Gas, mercaptansammonia )

Wastewater

Page 4: CITY OF COLUMBUS ODOR CONTROL PROGRAM• Repaired diffuser pipes • Washed inorganic media and reused • Installed locally sourced, organic media • Increased Air Flow to 12,000

CITY OF COLUMBUS ODOR CONTROL FACILITIES

• Upper Scioto West Interceptor Sewer (USWIS) Biofilters

• Big Walnut Augmentation and Rickenbacker Interceptor (BWARI) Biofilter

• Olentangy Scioto Interceptor Sewer (OSIS) Downtown Biofilters

• Lockbourne Intermodal Subtrunk(LIS) Biofilters (

• Blacklick Creek Interceptor Sewer (BCIS) Biofilter

Presenter
Presentation Notes
Upper Scioto West Interceptor Sewer (USWIS) Biofilters (1999 original construction, 2006, 2011 & 2016 rehabilitation) Big Walnut Augmentation and Rickenbacker Interceptor (BWARI) Biofilter (2009 original construction, 2017 rehabilitation) Olentangy Scioto Interceptor Sewer (OSIS) Downtown Biofilters (2012) Lockbourne Intermodal Subtrunk (LIS) Biofilters (2018) Blacklick Creek Interceptor (BCIS) Biofilter (2021)
Page 5: CITY OF COLUMBUS ODOR CONTROL PROGRAM• Repaired diffuser pipes • Washed inorganic media and reused • Installed locally sourced, organic media • Increased Air Flow to 12,000

USWIS Biofilters• Constructed to ventilate pressurized tunnel and provide odor removal• 2 Biofilters – 7,000 CFM Each (original design)

Page 6: CITY OF COLUMBUS ODOR CONTROL PROGRAM• Repaired diffuser pipes • Washed inorganic media and reused • Installed locally sourced, organic media • Increased Air Flow to 12,000

USWIS Biofilters

Aggregate for Underdrain and Main Air Distribution Header

Air Distribution Laterals

HDPE Liner

Page 7: CITY OF COLUMBUS ODOR CONTROL PROGRAM• Repaired diffuser pipes • Washed inorganic media and reused • Installed locally sourced, organic media • Increased Air Flow to 12,000

USWIS Biofilters

Inorganic (Granite) Media

Organic Media (Hardwood Mulch)

Page 8: CITY OF COLUMBUS ODOR CONTROL PROGRAM• Repaired diffuser pipes • Washed inorganic media and reused • Installed locally sourced, organic media • Increased Air Flow to 12,000

USWIS Biofilters• 2006 Media

Replacement• Organic media had

decomposed

Page 9: CITY OF COLUMBUS ODOR CONTROL PROGRAM• Repaired diffuser pipes • Washed inorganic media and reused • Installed locally sourced, organic media • Increased Air Flow to 12,000

USWIS Biofilters• Repaired diffuser

pipes• Washed inorganic

media and reused• Installed locally

sourced, organic media

• Increased Air Flow to 12,000 CFM at North Filter

Page 10: CITY OF COLUMBUS ODOR CONTROL PROGRAM• Repaired diffuser pipes • Washed inorganic media and reused • Installed locally sourced, organic media • Increased Air Flow to 12,000

USWIS Biofilters2009-2011 – Locally sourced, organic media had become anaerobic from decomposition.

Organic media was replaced with southern, yellow pine bark nuggets.

Page 11: CITY OF COLUMBUS ODOR CONTROL PROGRAM• Repaired diffuser pipes • Washed inorganic media and reused • Installed locally sourced, organic media • Increased Air Flow to 12,000

BWARI Biofilter

Page 12: CITY OF COLUMBUS ODOR CONTROL PROGRAM• Repaired diffuser pipes • Washed inorganic media and reused • Installed locally sourced, organic media • Increased Air Flow to 12,000

BWARI Biofilter

Page 13: CITY OF COLUMBUS ODOR CONTROL PROGRAM• Repaired diffuser pipes • Washed inorganic media and reused • Installed locally sourced, organic media • Increased Air Flow to 12,000

BWARI Biofilter

• Humidification System– NPW– Boiler– Spray Nozzles– Recirculation Pumps– Controls

Page 14: CITY OF COLUMBUS ODOR CONTROL PROGRAM• Repaired diffuser pipes • Washed inorganic media and reused • Installed locally sourced, organic media • Increased Air Flow to 12,000

BWARI Biofilter

Page 15: CITY OF COLUMBUS ODOR CONTROL PROGRAM• Repaired diffuser pipes • Washed inorganic media and reused • Installed locally sourced, organic media • Increased Air Flow to 12,000

BWARI Biofilter• Air Distribution

Issues

Page 16: CITY OF COLUMBUS ODOR CONTROL PROGRAM• Repaired diffuser pipes • Washed inorganic media and reused • Installed locally sourced, organic media • Increased Air Flow to 12,000

OSIS Downtown Biofilters

Page 17: CITY OF COLUMBUS ODOR CONTROL PROGRAM• Repaired diffuser pipes • Washed inorganic media and reused • Installed locally sourced, organic media • Increased Air Flow to 12,000

OSIS Downtown Biofilters• Foul air duct from sewer• Blower to draw foul air• Air distribution system

• Filter Media• Irrigation System• Leachate Drainage System

Page 18: CITY OF COLUMBUS ODOR CONTROL PROGRAM• Repaired diffuser pipes • Washed inorganic media and reused • Installed locally sourced, organic media • Increased Air Flow to 12,000

OSIS Downtown Biofilters

Page 19: CITY OF COLUMBUS ODOR CONTROL PROGRAM• Repaired diffuser pipes • Washed inorganic media and reused • Installed locally sourced, organic media • Increased Air Flow to 12,000

OSIS Downtown Biofilters

Page 20: CITY OF COLUMBUS ODOR CONTROL PROGRAM• Repaired diffuser pipes • Washed inorganic media and reused • Installed locally sourced, organic media • Increased Air Flow to 12,000

OSIS Downtown Biofilters

Page 21: CITY OF COLUMBUS ODOR CONTROL PROGRAM• Repaired diffuser pipes • Washed inorganic media and reused • Installed locally sourced, organic media • Increased Air Flow to 12,000

OSIS Downtown Biofilters

Page 22: CITY OF COLUMBUS ODOR CONTROL PROGRAM• Repaired diffuser pipes • Washed inorganic media and reused • Installed locally sourced, organic media • Increased Air Flow to 12,000

OSIS Downtown Biofilters

Presenter
Presentation Notes
Want even air distribution, so screen media to ensure uniformity.
Page 23: CITY OF COLUMBUS ODOR CONTROL PROGRAM• Repaired diffuser pipes • Washed inorganic media and reused • Installed locally sourced, organic media • Increased Air Flow to 12,000

OSIS Downtown Biofilters

Page 24: CITY OF COLUMBUS ODOR CONTROL PROGRAM• Repaired diffuser pipes • Washed inorganic media and reused • Installed locally sourced, organic media • Increased Air Flow to 12,000

OSIS Downtown Biofilters

Page 25: CITY OF COLUMBUS ODOR CONTROL PROGRAM• Repaired diffuser pipes • Washed inorganic media and reused • Installed locally sourced, organic media • Increased Air Flow to 12,000

OSIS Downtown Biofilters

Page 26: CITY OF COLUMBUS ODOR CONTROL PROGRAM• Repaired diffuser pipes • Washed inorganic media and reused • Installed locally sourced, organic media • Increased Air Flow to 12,000

OSIS Downtown Biofilters

Page 27: CITY OF COLUMBUS ODOR CONTROL PROGRAM• Repaired diffuser pipes • Washed inorganic media and reused • Installed locally sourced, organic media • Increased Air Flow to 12,000

USWIS Biofilters2016 Reconstruction of north and south filters.• Removed existing filter

beds and replaced them with our new plenum design.

• Utilizing lava rock with western pine nugget media at the south filter.

• Utilizing engineered media at the north site.

• Installing aluminum covers.

Page 28: CITY OF COLUMBUS ODOR CONTROL PROGRAM• Repaired diffuser pipes • Washed inorganic media and reused • Installed locally sourced, organic media • Increased Air Flow to 12,000

BWARI Biofilter Rebuild (2017)Remove:– Humidification SystemReplace:– Hatches– Dampers– Entire Electrical & Control

System– Fan bearings and shaft seals– Irrigation system– Coatings– Conduits and terminals– Gate Actuators

Improve:– Increase capacity from 23,000

CFM to 35,000 CFM– Large Western Fir Bark nuggets in

place of root wood mulch– Surface Irrigation– Electrical upgrades (MCC,

conductors, AFDs)– Corrosion inhibitors in all panels– Simplify controls and monitoring

system– Building ventilation

Page 29: CITY OF COLUMBUS ODOR CONTROL PROGRAM• Repaired diffuser pipes • Washed inorganic media and reused • Installed locally sourced, organic media • Increased Air Flow to 12,000

LIS Biofilters

Page 30: CITY OF COLUMBUS ODOR CONTROL PROGRAM• Repaired diffuser pipes • Washed inorganic media and reused • Installed locally sourced, organic media • Increased Air Flow to 12,000

LIS Biofilters• Constructed to ventilate pressurized tunnel and provide odor removal• 2 Biofilters – 5,000 CFM Each

Biofilter Cell

Pre-Manufactured Fan Building

Page 31: CITY OF COLUMBUS ODOR CONTROL PROGRAM• Repaired diffuser pipes • Washed inorganic media and reused • Installed locally sourced, organic media • Increased Air Flow to 12,000

Biofilter DesignVentilation Rates• Modelling• Field Testing – pressure &

hydrogen sulfide

Foul Air Stream Characterization• Odor Constituents• Seasonal Variations• Wet Weather Impacts• Operational Impacts

Page 32: CITY OF COLUMBUS ODOR CONTROL PROGRAM• Repaired diffuser pipes • Washed inorganic media and reused • Installed locally sourced, organic media • Increased Air Flow to 12,000

Biofilter Design Criteria

32

BiofilterSection

(min))()( TimeContactBedEmpty

cfmAirofFlowMasscfBiofilterofVolume

=

EBCT= 60-90 min

)/()(

)( sfCfmRateLoadingsfBiofilterofArea

cfmAirofrateflowMass=

Loading Rate = ~6 Cfm/sf

~1 ft deepTrench ~ 1,000 ft/min

BiofilterPlan

Exhaust Duct

Page 33: CITY OF COLUMBUS ODOR CONTROL PROGRAM• Repaired diffuser pipes • Washed inorganic media and reused • Installed locally sourced, organic media • Increased Air Flow to 12,000

Biofilter DesignDuct And Piping Considerations

• Corrosion Resistance• PVC (small diameters)• Fiberglass Reinforced Polymer

Pipe (large diameters)• Dampers

Blower Considerations• Corrosion Resistant• Variable Speed• Vibration• Noise• Foul Air Duct Connection

Presenter
Presentation Notes
Corrosive environment
Page 34: CITY OF COLUMBUS ODOR CONTROL PROGRAM• Repaired diffuser pipes • Washed inorganic media and reused • Installed locally sourced, organic media • Increased Air Flow to 12,000

Biofilter DesignPlenum Considerations• Perforated Pipe and Stone• Pre-manufactured Plastic Floor

• Hallsten• BACTee

Page 35: CITY OF COLUMBUS ODOR CONTROL PROGRAM• Repaired diffuser pipes • Washed inorganic media and reused • Installed locally sourced, organic media • Increased Air Flow to 12,000

Biofilter DesignDual Media Filters

• Organic and Inorganic Media (<0.25 in-H20)• Proven to produce effluent with < 0.005 ppm H2S

Pilot Tested Inorganic Media• Crushed Granite (limestone degrades)• Lava Rock • Tire Chips

Lava Rock Advantages• H2S Removal• Airflow Characteristics• Moisture Retention• Light Weight (compared to granite)

Page 36: CITY OF COLUMBUS ODOR CONTROL PROGRAM• Repaired diffuser pipes • Washed inorganic media and reused • Installed locally sourced, organic media • Increased Air Flow to 12,000

Biofilter DesignIrragation System Considerations• Sprinklers (with automatic controls system)• Drip tubes• Humidification

chambersOperational Considerations• Remote monitoring parameters• Security• Control requirements• Communication paths• Training• Maintenance• Monitoring

Presenter
Presentation Notes
Used basic sprinklers – simplest. Drip tubes must be replaced with media. Humidifcation chamber not needed – air in sewer is very humid. Controls – combined sewer issues with surcharging.
Page 37: CITY OF COLUMBUS ODOR CONTROL PROGRAM• Repaired diffuser pipes • Washed inorganic media and reused • Installed locally sourced, organic media • Increased Air Flow to 12,000

Odor Control Philosophy • Keep it Simple & Uniform• Proper Design Yields Low Maintenance & High Performance

Page 38: CITY OF COLUMBUS ODOR CONTROL PROGRAM• Repaired diffuser pipes • Washed inorganic media and reused • Installed locally sourced, organic media • Increased Air Flow to 12,000

Thanks for Listening

Any Questions?